Preview only show first 10 pages with watermark. For full document please download

16scyq030c Schottky Rectifier 16 Amp, 30v High Efficiency Series

   EMBED


Share

Transcript

PD-93964A 16SCYQ030C SCHOTTKY RECTIFIER HIGH EFFICIENCY SERIES 16 Amp, 30V Major Ratings and Characteristics Characteristics Limits Description / Features IF(AV) 16 A VRRM (Per Leg) 30 V IFSM @ tp = 8.3ms half-sine (Per Leg) 150 A 0.54 V -55 to 150 °C VF @ 16Apk, TJ =125°C (Per Leg) TJ,Tstg Operating and storage The 16SCYQ030C center tap Schottky rectifier has been expressly designed to meet the rigorous requirements of high reliability environments. It is packaged in the hermetic isolated TO-257AA package. The device's forward voltage drop and reverse leakage current are optimized for the lowest power loss and the highest circuit efficiency for typical high frequency switching power supplies and resonent power converters. Full MIL-PRF-19500 quality conformance testing is available on source control drawings to TX, TXV and S quality levels. Units • • • • • • Hermetically Sealed Center Tap Ceramic Eyelets Low Forward Voltage Drop High Frequency Operation Guard Ring for Enhanced Ruggedness and Long term Reliability • Lightweight 0.13 [.005] A CASE STYLE 3.81 [.150] 3X Ø 3.56 [.140] 10.66 [.420] 10.42 [.410] 16.89 [.665] 16.39 [.645] 13.63 [.537] 13.39 [.527] 1 2 5.08 [.200] 4.83 [.190] 1.14 [.045] 0.89 [.035] B 10.92 [.430] 10.42 [.410] 3 0.71 [.028] MAX. C 15.88 [.625] 12.70 [.500] 2.54 [.100] 2X 3X Ø 0.88 [.035] 0.64 [.025] Ø 0.50 [.020] C A 3.05 [.120] B NOT ES : 1. 2. 3. 4. DIMENS IONING & T OLERANCING PER ANS I Y14.5M-1994. CONT ROLLING DIMENS ION: INCH. DIMENS IONS ARE S HOWN IN MILLIMET ERS [INCHES ]. OUT LINE CONF ORMS T O JEDEC OUT LINE T O-257AA. 1 2 3 ANODE COMMON ANODE CATHODE Case Outline and Dimensions - TO-257AA www.irf.com 1 02/07/08 16SCYQ030C Voltage Ratings Part number VR 16SCYQ030C Max. DC Reverse Voltage (V) (Per Leg) 30 VRWM Max. Working Peak Reverse Voltage (V) (Per Leg) Absolute Maximum Ratings Parameters IF(AV) Max. Average Forward Current Limits Units Conditions 16 A 50% duty cycle @ TC = 138°C, square waveform 150 A @ tp = 8.3 ms half-sine See Fig. 5 IFSM Max. Peak One Cycle Non - Repetitive Surge Current (Per Leg) Electrical Specifications Parameters V FM Max. Forward Voltage Drop (Per Leg) See Fig. 1 I RM Limits Units 0.57 V @ 7.5A Conditions 0.65 V @ 15A 0.66 V @ 16A TJ = -55°C ‚ 0.48 V @ 7.5A 0.58 V @ 15A 0.60 V @ 16A 0.365 V @ 7.5A 0.52 V @ 15A 0.54 V @ 16A Max. Reverse Leakage Current 1.0 mA (Per Leg) See Fig. 2 117 mA TJ = 100°C 150 mA TJ = 125°C VR = 5VDC ( 1MHz, 25°C ) ‚ CT Max. Junction Capacitance (Per Leg) 1900 pF LS Typical Series Inductance (Per Leg) 6.9 nH TJ = 25°C ‚ TJ = 125°C ‚ TJ = 25°C VR = rated VR ‚ Measured from anode lead to cathode lead 6mm ( 0.025 in.) from package Thermal-Mechanical Specifications Limits Units TJ Parameters Max.Junction Temperature Range -55 to 150 °C Tstg Max. Storage Temperature Range -55 to 150 °C 1.6 °C/W DC operation 0.8 °C/W DC operation RthJC Max. Thermal Resistance, Junction Conditions See Fig. 4 to Case (Per Leg) RthJC Max. Thermal Resistance, Junction to Case (Per Package) wt Weight (Typical) Die Size (Typical) Case Style 4.3 g 115X170 mils T0-257AA  Pulse Width < 300µs, Duty Cycle < 2% 2 www.irf.com 16SCYQ030C Reverse Current - I R ( mA ) 1000 Instantaneous Forward Current - I F (A) 100 100 125°C 100°C 10 75°C 1 25°C 0.1 0.01 0 10 20 30 Reverse Voltage - VR (V) Fig. 2 - Typical Values of Reverse Current Vs. Reverse Voltage (Per Leg) 10 Tj = 125°C 10000 Tj = -55°C 1 0.0 0.2 0.4 0.6 0.8 1.0 Forward Voltage Drop - V F (V) Fig. 1 - Max. Forward Voltage Drop Characteristics (Per Leg) Junction Capacitance - CT (pF) Tj = 25°C T J = 25°C 1000 100 0 10 20 30 Reverse Voltage -V R (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage (Per Leg) www.irf.com 3 16SCYQ030C Thermal Response (Z thJC ) 10 1 D = 0.50 0.20 0.10 0.1 0.01 0.00001 PDM 0.05 0.02 0.01 t1 t2 SINGLE PULSE (THERMAL RESPONSE) 0.0001 Notes: 1. Duty factor D = t 1 / t 2 2. Peak TJ = P DM x Z thJC + TC 0.001 0.01 0.1 1 10 t1 , Rectangular Pulse Duration (sec) Fig. 4 - Max. Thermal Impedance ZthJC Characteristics (Per Leg) Allowable Case Temprature - (°C) 180 16SCYQ030C 160 R thJC = 1.6°C/W 140 DC 120 100 80 60 40 20 0 0 10 20 30 Average Forward Current - I F(AV) (A) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current (Per Leg) IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 IR LEOMINSTER : 205 Crawford St., Leominster, Massachusetts 01453, USA Tel: (978) 534-5776 TAC Fax: (310) 252-7903 Visit us at www.irf.com for sales contact information. Data and specifications subject to change without notice. 02/2008 4 www.irf.com