Preview only show first 10 pages with watermark. For full document please download

1801ms Datasheet English - Ses

   EMBED


Share

Transcript

SES-ASA ENGINEERING S.r.l. FIRE & GAS – FIRE PROTECTION Legal Seat : Via G. Galilei N. 5 - 20091 Bresso (MI) - Italy Factory: Via C. Romani N.8/10 - 20091 Bresso (MI) – Italy Tel.: +39 02 610371 Fax.: +39 02 66507091 Web site : www.ses-enser.com - E-mail: [email protected] •1810 GX • Card Controller Toxic Gas Detector Features • • • • • • • • 3 Unit Extended - 19’’ Rack mounting 24 Vdc power supply Analogue Input Std.4÷20 (0÷22mA.). Monitoring Single point Toxic Gas Detection Open Collector Outputs for Warning, Alarm, Fault, Inhibit, Siren. Relays outputs for Warning, Alarm and Fault. Output 0÷22mA repeater Signalling LED of status and DISPLAY for measuring ppm. Applications • Toxic Gas Detection Controller for industrial application like Petrochemical Plants, Refineries, Ammonia Plant Conservation Industry, Food & Beverage, etc… . Description • • • • • • • • The 1810 GX can be considered one of the enhanced stand alone control unit available on the market for what concern Toxic Gas detection for industrial applications which Hydrogen Sulphide (H2S), Sulphur Dioxide (SO2), Carbon Monoxide (CO), Ammonia (NH3), etc… . The 1810 GX interfaces directly with Transmitter/Smart Sensor with output 0÷22mA this features permit connections to many different type of Transmitter Sensor available on market, at 2, 3 or 4 wires connections and Intrinsically Safe connection. The microprocessor single chip used, present on all 1800 range, have several advantages of application and high reliability. Through the card Dip Switches, it is possible to configure the functional parameters in order to make it able to responds to the applications required, such as: configuration of Outputs Open Collector and Relay normally de-energised or energised; latching or no-latching Relay outputs. A complete self-diagnostic, possible for the use of microprocessor, permits a control and verification components functionality on the board, activating, in case of trouble, the fault outputs. On the front panel of the card are present the redundant signalling LED’s to show the WARNING ALARM FAULT INHIBIT and READY (Watch Dog circuit) Status. The push buttons on the front panel allow the operation of Inhibit of Input Channel and Set push button to change Warning and Alarm threshold and full scale. Through two digit display is visible the measuring in “ppm” and in operating mode view and set all parameters. Available Output 0÷22mA repeater function to connect printer/data logger. Interface field connections by DIN 41612 male connector 32 pins D/Z. Connection user view Connector Card 1810 GX D Pin Z OUT K1 A com 02 OUT K1 B com OUT K1 A n.o. 04 OUT K1 B n.o. OUT K1 A n.c. 06 OUT K1 B n.c. OUT K2 A com 08 OUT K2 B com OUT K2 A n.o. 10 OUT K2 B n.o. OUT K2 A n.c. 12 OUT K2 B n.c. OUT K3 n.o. 14 OUT K3 n.c. OUT K3 com 16 OUT O.C.5 OUT O.C.1 18 OUT O.C.2 OUT O.C.3 20 OUT O.C.4 INPUT +24Vdc 22 OUT +24Vdc INPUT -0Vdc 24 OUT -0Vdc OUT 0-22mA 26 OUT 0-22mA (SGN+) (SGN-/COM) IN ACK 28 Ref. Tab.1 IN RESET 30 Ref. Tab.1 IN LAMP TEST 32 Not use Tab.1 Connection 3-4 Wires Connection 2 Wires 28Z – Signal IN + 28Z – Signal IN + 30Z – Signal IN - / 0V 30Z – Signal IN - / 0V 22Z – +24Vdc 24Z-0V LEGEND: K com= Relay common contact K n.o. = Relay contact normally open K n.c. = Relay contact normally closed O.C. = Open Collector Technical Specifications Applications: Toxic Gas Detection directly connection of Gas detector installed in safe area to the card and via galvanic isolation, safety barrier, for 0÷22mA or Std.4÷20mA installed in hazardous area. Guarantee: 2 years Operative area: Safety area Front panel signalling LED’s: Warning - Alarm – Fault - Inhibit Watch-Dog active (Ready) Status Two digit display ppm detected Front panel push button commands: INH Input Inhibition SET View set-point ZERO Active during calibration step SPAN Active during calibration step ↑↓ Scroll data Mechanical specifications Card ◊ ◊ ◊ ◊ Size Height and length Front panel width Weight :3HE Std Europe Extended :100 x 220mm :5TE (1’’,25,4 mm) :280 g Rack ◊ ◊ ◊ ◊ ◊ Size Weight Height and length. Connection Wire section :19’’ 3 Unit Extended :1000 g :132 x 280 mm :Screw/Fast-on to DIN41612 :0,5mm÷4mm (22÷18 AWG) Operating Conditions ◊ Operating temperature :0°C÷+70°C (+32°F÷+158°F) ◊ Storage temperature :-40°C÷+85°C (-40°F÷+185°F) ◊ Operating humidity :0%÷95% non condensing Electrical specifications ◊ ◊ ◊ ◊ Input Power supply :24Vdc Nom. (20÷30Vdc) Power consumption :3W Nom. | 4,5W Max P.S. fuse protection. :500mA Retard (5x20mm) Analogue Input signal : Std. 4÷20mA (0÷22mA) Use cable with 2-3-4 core conductor shielded or shielded and armoured. The connection at Transmitter/Smart Sensor 4÷20mA (0÷22mA) is 600 ohm max. @ 24Vdc. (See Tab.2) Tab.2 Input 4÷20mA (0÷22mA) mm2 2.5 1.5 1.0 AWG 14 16 18 Metri 1372 685 488 Feet 4500 2250 1600 ◊ Digital Input signals :ACK, RESET & L.TEST These commands must be impulsive type activated through logic ground (0 Volt) for minimum times of 200 msec. ◊ Open Collector Outputs (NPN) 0,1A @ 30Vdc Max. - OC1 Alarm - OC2 Warning - OC3 Fault - OC4 Inhibit - OC5 Siren (Silence by Acknowledge) Relay Output with maximum resistive contacts loads of : 30Vcc @ 1A Max. | 125/250Vca @ 0.3A Max. (K3) 30Vcc @ 3A Max. | 125/250Vca @ 4A Max. (K1-K2) Relay K1 DPDT Alarm Relay K2 DPDT Warning Relay K3 SPDT Fault ◊ Approval :CE mark ◊ 0÷22mA Output (Output repeater) ◊ RFI/EMI protections :EN55011, EN50082-2 IEC 801-2, IEC 801-4 Ordering Information’s Card 1810GX Smart Sensor S500.01.CO.100ppm Smart Sensor S500.02.H2S.20ppm Smart Sensor S500.12.NH3.50ppm Smart Sensor S500.04.S02.20ppm Card 1810F-4TE Facility Connector fast-on Din 41612 Rack 19” 3U Extended (16+1 Slots) Blank Panel 5TE-3HE code 034625 code 135034 code 135093 code 135057 code 135015 code 034580 code 026026 code 081040 code 080549 Specifications subjected to changes without notice. SES-DS-1810GX-E Rev. 2