Preview only show first 10 pages with watermark. For full document please download

187-05006-06 Sfp+ Zr C-band Tunable 10gb

   EMBED


Share

Transcript

50GHz Full C-band Tunable 10GBASE-ZR/OC-192 LR-2 SFP+ Transceiver 10Gb/s 80km P/N 5ZR0A0x-TNBL Applications • • • • • Full C-band Tunable 10GBASE-ZR 10GEthernet 8GB/10GB Fibre Channel SONET OC-192 LR-2 SDH STM-64 ITU-T G.959.1 P1L1-2D2 Access DWDM Ethernet Switch or IP Router Interconnect Features Description Menara Networks’ 50GHz Full C-band Tunable 5ZR0A0x-TNBL SFP+ transceivers are designed for use in 10Gb/s to 11.1Gb/s 50GHz DWDM links up to 80km of G.652 fiber. The SFP+ module supports 10GBASE-ZR and –ZW applications along with SONET OC-192 LR-2 and SDH STM-64 ITU-T G.959.1 P1L1-2D2 applications for Ethernet Switches, IP Routers or SONET/SDH optical interfaces. Digital Optical Monitoring interfaces are 2 provided via the SFP+ standards compliant I C interface. • • • • • • • • • • • • • • • • • Hot-pluggable SFP+ footprint 50GHz DWDM ITU-T Full C-band Tunability Support 9.95Gb/s to 11.3Gb/s bit rates 80km 50GHz DWDM laser 80km APD photodiode receiver Single 3.3V power supply Power dissipation < 2.0W -5°C to +70°C Duplex LC fiber connectors 10GBASE-ZR/ZW SDH STM-64 ITU-T G.959.1 P1L1-2D2 Full Digital Optical Monitoring Metal enclosure for lower EMI Complies with RoHS directive (2002/95/EC) Compliant with SFP+ Electrical MSA SFF8431 Compliant with SFP+ Mechanical MSA SFF-8432 Laser Class 1 IEC/CDRH compliant Transmitter E-O Characteristics Parameter Support data rate Center Wavelength (DWDM) Wavelength Stability after Startup DWDM Channel Spacing Tuning Time Average Optical Output Power Optical Power of Off Transmitter Extinction Ratio Side Mode Suppression Ratio Tx Eye Crossing Output Eye Diagram 31 1. 10.709Gbps, PRBS 2 -1 Symbol λ ΔλEOL fSPACING ΔTUNE Po Poff Er SMSR Min. 9.95 1528.38 λi -25 Typ. 10.3125 50 -1.0 9.0 35 45 - Max. 11.1 1565.50 λi +25 1 +3.0 -30 - 60 Compliant with SFP+ MSA Unit Gb/s nm pm GHz sec dBm dBm dB dB % Note ITU-T 1 1 Receiver O-E Characteristics Parameter Symbol Min. Typ. Max. Unit Note Support data rate 9.95 10.3125 11.1 Gb/s Operating Wavelength 1525 1570 nm Sensitivity @ 9.95 to 10.3Gbps Sen1 -24 dBm 1 Sensitivity @ 11.1Gbps Sen2 -23 dBm 1 Saturation Ps -7 dBm 1 Optical Path Penalty @ 9.95Gbps OPP1 2 dB 1 1600ps/nm Optical Path Penalty @ 10.7Gbps OPP2 2.5 dB 1 1600ps/nm Optical Path Penalty @ 11.1Gbps OPP3 3 dB 1 1450ps/nm Rx Damage Threshold RXDAMAGE 1 dBm LOS Asserted (EOL) T_loss_on -40.0 -27.5 dBm High LOS De-Asserted T_loss_off -27 dBm level: Alarm LOS Hysteresis (EOL) T_loss_Hs 0.5 dB Notes: 1. Rx wavelength range is 1270nm to 1610nm with 2dB penalty outside of specified operating range 31 -12 2. PRBS 2 -1 at 10 BER Pin Out Contact case 1 2 3 4 5 Logic Symbol LVTTL-O LVTTL-I case VeeT Tx_Fault Tx_Disable Power Sequence See 1 st 1 rd 3 rd 3 SDA 3 rd SCL 3 rd LVTTLI/O LVTTLI/O Name/Description Module case Module Transmitter Ground Module Transmitter Fault Transmitter Disable; Turns off transmitter laser output 2-wire Serial Interface Data Line Note 2 3 4 2-wire Serial Interface Clock rd 6 Mod_ABS 3 Module Absent rd 7 LVTTL-I RS0 3 Rate Select 0 (Not used) rd 8 LVTTL-O Rx_LOS 3 Receiver Loss of Signal Indication rd 9 LVTTL-I RS1 3 Rate Select 1 (Not used) st 10 VeeR 1 Module Receiver Ground st 11 VeeR 1 Module Receiver Ground rd 12 CML-O RD3 Receiver Inverted Data Output rd 13 CML-O RD+ 3 Receiver Non-Inverted Data Output st 14 VeeR 1 Module Receiver Ground nd 15 VccR 2 Module Receiver 3.3 V Supply nd 16 VccT 2 Module Transmitter 3.3 V Supply st 17 VeeT 1 Module Transmitter Ground rd 18 CML-I TD+ 3 Transmitter Non-Inverted Data Input rd 19 CML-I TD3 Transmitter Inverted Data Input st 20 VeeT 1 Module Transmitter Ground 1. The case makes electrical contact to the cage before any of the board edge contacts are made. 2. The module signal ground contacts, VeeR and VeeT, should be isolated from the module case. 3. This contact is an open collector/drain output contact and shall be pulled up on the host. 4. Tx_Disable is an input contact with a 4.7 kΩ to 10 kΩ pullup to VccT inside the module. 3 2 2 2 2 2 Absolute Maximum Ratings Parameter Power Supply Storage Temperature Operating Temperature Relative Humidity (non condensing) Symbol Vcc TSTORAGE TOP RH Min. -0.5 -40 -5 5 Typ. Max. 3.7 85 70 85 Unit V C C % Note Symbol Vcc Icc PDIS Min. 3.13 Typ. Max. 3.47 0.65 2 Unit V A W Note Symbol VOL IOH VIL Min. -0.3 -50 -0.3 Typ. Symbol RIN VIN, PP VOUT, PP T R, T F Min. Typ. 100 Electrical Characteristics Power Supply Parameter Power Supply Supply Current Power Dissipation Low Speed Control and Sense Signals Parameter Max. Unit Note 0.40 V Tx_Fault, Rx_LOS 37.5 µA 1 0.8 V Tx_Disable, RS0, RS1 VccT + IIH 2.0 V 0.3 1. Measured with a 4.7 kΩ load pulled up to Vcc_Host where Vcc_Host_min < Vcc_host < Vcc_Host_max High Speed Signals Parameter Input Differential Impedance Differential Swing Differential Data Output Swing Output Rise Time and Fall Time 1. Into 100 Ω differential termination 7 2. 20% - 80%, PRBS 2 -1 180 300 28 Max. 700 850 Unit Ω mV mV ps Note 1 Management Timing Parameters Parameter Tx_Disable assert time Symbol t_off Tx_Disable negate time Min. Max. 100 Unit ìs t_on 2 ms Time to initialize 2-wire interface Time to initialize t_2w_start_up 300 ms t_start_up 300 ms Tx_Fault assert Tx_Fault_on 1 ms Tx_Fault Reset t_reset Rx_LOS assert delay t_los_on 100 µs Rx_LOS negate delay t_los_off 100 µs 10 µs Note Rising edge of Tx_Disable to fall of output signal below 10% of nominal Falling edge of Tx_Disable to rise of output signal above 90% of nominal. This only applies in normal operation, not during start up or fault recovery. From power on or hot plug From power supplies meeting required specification or hot plug or Tx disable negated during power up, or Tx_Fault recovery, until noncooled part is fully operational. From occurrence of fault to assertion of Tx_Fault Time Tx_Disable must be held high to reset Tx_Fault From occurrence of loss of signal to assertion of Rx_LOS From occurrence of presence of signal to negation of Rx_LOS Management Interface The Tunable SFP+ supports the enhanced digital diagnostic interface. The enhanced interface uses the two wire serial bus address 1010001X (A2h) to provide diagnostic information about the module’s present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. The SFP+ memory map is shown below: DOM Accuracy and I2C Locations MSA Register 96-97 98-99 100-101 102-103 104-105 Size Name Accuracy Description 2 2 2 2 2 Transceiver Temperature Vcc, measured internally Laser Bias Current Laser Output Power Receive Optical Power +/- 4 Degrees C +/- 3% +/- 5% +/- 2dB +/- 2dB (from -5dBm to -30dBm) MSB at low address MSB at low address MSB at low address MSB at low address MSB at low address Regulatory and Safety Compliance Parameter Product safety Laser safety Radiated emission Immunity Radiated immunity RoHS Standard UL 60950-1 CSA C22.2 No. 60950-1 EN 60950-1 IEC 60950-1 Flame Class V-0 Low Voltage Directive 2006/95/EC EN 60825-1, EN 60825-2 IEC 60825-1 U. S. 21CFR 1040.10 EMC Directive 2004/108/EC FCC rules 47 CFR Part 15 CISPR 22 AS/NZS CISPR22 EN 55022 ICES-003, Issue 5 VCCI V-3 EMC Directive 2004/108/EC CISPR 24 EN 55024 IEC/EN 61000-4-3 EU Directive 2002/95/EC + EU Directive 2011/65/EU Note Class 1 Laser Class B ROHS 6 Ordering Information Part Number 5ZR0A0x-TNBL ROHS Compliant ROHS-6 Operating Case Temperature -5 ~ +70°C x = J for Juniper x = C for Cisco x = A for Alcatel x = O for Cisco ONS [email protected] www.menaranet.com Wavelengths Supported The following table provides correlation of the ITU-T DWDM channel number, wavelength and frequency. Freq (THz) 196.15 196.10 196.05 196.00 195.95 Wavelength 1528.38 1528.77 1529.16 1529.55 1529.94 ITU Ch. 61.5 61 60.5 60 59.5 195.90 195.85 195.80 195.75 195.70 1530.33 1530.72 1531.12 1531.51 1531.90 59 58.5 58 57.5 57 195.65 195.60 195.55 195.50 195.45 1532.29 1532.68 1533.07 1533.47 1533.86 195.40 195.35 195.30 195.25 195.20 Freq (THz) Wavelength ITU Ch. Freq (THz) Wavelength ITU Ch. 194.40 1542.14 44 192.65 1556.15 26.5 194.35 194.30 194.25 194.20 194.15 1542.54 1542.94 1543.33 1543.73 1544.13 43.5 43 42.5 42 41.5 192.60 192.55 192.50 192.45 192.40 1556.55 1556.96 1557.36 1557.77 1558.17 26 25.5 25 24.5 24 194.10 194.05 194.00 193.95 1544.53 1544.92 1545.32 1545.72 41 40.5 40 39.5 192.35 192.30 192.25 192.20 1558.58 1558.98 1559.39 1559.79 23.5 23 22.5 22 56.5 56 55.5 55 54.5 193.90 193.85 193.80 193.75 193.70 1546.12 1546.52 1546.92 1547.32 1547.72 39 38.5 38 37.5 37 192.15 192.10 192.05 192.00 191.95 1560.20 1560.61 1561.01 1561.42 1561.83 21.5 21 20.5 20 19.5 1534.25 1534.64 1535.04 1535.43 1535.82 54 53.5 53 52.5 52 193.65 193.60 193.55 193.50 193.45 1548.11 1548.51 1548.91 1549.32 1549.72 36.5 36 35.5 35 34.5 191.90 191.85 191.80 191.75 191.70 1562.23 1562.64 1563.05 1563.45 1563.86 19 18.5 18 17.5 17 195.15 195.10 195.05 195.00 1536.22 1536.61 1537.00 1537.40 51.5 51 50.5 50 194.95 194.90 194.85 194.80 194.75 1537.79 1538.19 1538.58 1538.98 1539.37 49.5 49 48.5 48 47.5 193.40 193.35 193.30 193.25 193.20 1550.12 1550.52 1550.92 1551.32 1551.72 34 33.5 33 32.5 32 191.65 191.60 191.55 191.50 191.45 1564.27 1564.68 1565.09 1565.50 1565.90 16.5 16 15.5 15 14.5 194.70 194.65 194.60 194.55 194.50 1539.77 1540.16 1540.56 1540.95 1541.35 47 46.5 46 45.5 45 193.15 193.10 193.05 193.00 192.95 1552.12 1552.52 1552.93 1553.33 1553.73 31.5 31 30.5 30 29.5 191.40 191.35 191.30 191.25 191.20 1566.31 1566.72 1567.13 1567.54 1567.95 14 13.5 13 12.5 12 192.90 192.85 192.80 192.75 1554.13 1554.54 1554.94 1555.34 29 28.5 28 27.5 191.15 191.10 1568.36 1568.77 11.5 11 194.45 1541.75 44.5 192.70 1555.75 27