The cables referred to below are provided with standard single- and multimode fibers. Other commercially available fibers can be provided on request. The bare fibers are colored in all cases with
UV-cured acrylate. The process employed is state of the art and guarantees a uniform, smooth surface. The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification. Equipotential bonding and lightning protection measures are not required because all the cables employed are free of metal. Universal Cables A link failure in a modern FO network can involve considerable costs for the operator. The cables must therefore meet stringent mechanical requirements and be able to withstand environmental effects such as frost and humidity. Accordingly, our FutureLink direct burial, duct and universal cables have been designed to be particularly rugged and resilient. For campus cabling applications there are MPC (Multi-Purpose Cables = in- and outdoor cables) available. MPC feature not only the outdoor characteristics (e. g. enhanced rodent protection, water blocking and UV resistance) but also the LS0H characteristics of the use FRNC material required for deployment in buildings. The cable sheaths are colored black. We provide two design variants: • Minibundle cables: Cables with multifiber buffer tubes stranded around a central non-metallic (dielectric) strength member. • Central tube cables: Cables with a central multifiber buffer tube and strength members partially integrated in the sheath. If a bundle is to contain more than the maximum of twelve fibers that can be distinguished visually, we group the fibers in twelves with a colored binder.
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
11 2 0 0 1
This avoids an additional stress being imposed on the individual optical fiber by the ring marking which would otherwise have to be used to identify more than 12 individual fibers. If, for instance, water enters the cable through damage to the sheath, a special filling prevents the water from migrating inside the cable. This is achieved by swellable (dry) water blocking elements. The advantage of these so-called “dry” cables is their enhanced installation handling and the environ-
Indoor Cables The cables used for the building backbone (riser) and horizontal subsystems are non-corrosive (to IEC 60754-2), low-smoke (to IEC 61034) and flame-retardant indoor cables (tested to IEC 60332-1 or –3 and DIN VDE 0472, part 804, test type C). The color of the cable sheaths is, unless stated otherwise, yellow for single-mode and orange for multimode fiber cables. With the new tight buffer coating TB3 our indoor FO cabling is even more installation-friendly, zero halogen and flame retardant. In addition, it has the following advantages: • installation-friendly as no filling compound, • very easy to strip, • long stripping lengths of about 150 mm, • rapid, direct field connectorization, • direct assembly of the tight buffer, • flame retardant to IEC 60332-3 • non-corrosive (halogen free). There are multifiber indoor, breakout and patch cables. Multifiber indoor cables consist of stranded tight buffers served with non-metallic strength members. Breakout cables comprise tight-buffered single-fiber cables (tight buffers each in own sheath) stranded together with a central tensile strength member under an additional shared sheath.
Cables
mental protection.
12
C o r n i n g C a b l e
S y s t e m s
By virtue of their similarities, multifiber indoor cables are often also called “mini-breakout” or “MIC” cables. Simplex and duplex cords are singlefiber or Zipcord cables with tight buffers. All FutureLink indoor FO cables are metal-free and hence • EMC immune • require no grounding • require no lightning protection • require no equipotential bonding. Pre-assembled Multifiber Cables, Pigtails and Patch Cords To enable FO cables to be joined and separated again rapidly without damage, they are terminated with connectors. In addition to pigtails and patch cords, Corning also supply multifiber cables in factory pre-assembled form such as MPC, MIC (Multifiber Indoor Cable) and breakout cables. The connectors available include not only the well-known SC and ST types but also the small form factor MT-RJ connectors that terminate two fibers simultaneously. For these connectors there are two-fiber cables available with geometry optimally configured for the MT-RJ connector (MiniMIC). For making the transition from MT-RJ to SC and ST single-fiber connectors there are suitable MiniZip cables available. Pre-assembled cables provide the possibility of implementing a complete “plug & play” solution. When such a solution is adopted with accurate dimensioning and suitable cable routing, it is possible to install even large cabling systems rapidly. Another advantage is that fusion splicing is not necessary. The “plug & play” technique is also prefered in clean envirement applications.
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
13 2 0 0 1
Technical Data Typical attenuation in the cable at 1310/1550 nm (dB/km)
Mode-field diameter (µm)
Mini- and Maxibundle (-tube) design
Tight buffer with 900 µm or 700 µm
9.2 ± 0.4
0.36/0.23
0.38/0.25
Standard multimode fiber
Typical attenuation in the cable at 850/1300 nm (dB/km)
Core diameter (µm)
Mini- and Maxibundle (-tube) design
Tight buffer with 900 µm or 700 µm
50 ± 3.0 62.5 ± 3.0
2.5/0.7 3.1/0.8
2.7/0.8 3.1/0.8
* Fibers with other bandwidths are available on request, e.g. 600/1200 at 50 µm.
Chromatic dispersion at 1310/1550 nm (ps/(nm x km))
≤ 3.5/≤ 18.0
Bandwidth* at 850/1300 nm (MHz x km)
400/1200 200/600
Cables
Standard single-mode fiber
C o r n i n g C a b l e
S y s t e m s
MPC (Multi-Purpose Cables) Minibundle MPC A–DQ(ZN)H Application FutureLink MPC (multi-purpose cables) can be used both indoors and outdoors for campus backbone and building backbone (riser) cabling. These cables are specially designed for placement in ducts, for pulling into duct systems or for direct burial.
Characteristics
No .o ff ib er s Ou ts id e di a. (m W m ei gh ) t( kg /k Te m ns ) ile fo lo ri ad ns ta Be llat nd ion ra ( in di N) st us al fo la ti r Be on nd (m ra m) in di us op er at io Fi n re ra (mm tin ) g (M J/ m )
Sw Ce FR NC nt el la ra s bl lm he e a m em e t M l em h em in be be ib en r, un rs ts m ,m dl et e al e w t -fr al ith -fr ee up ee to 12 fib er s, fil le d
• Low-smoke to IEC 61034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-1 and non-corrosive to IEC 60754-2 (FRNC) • Non-metallic design • No grounding or potential equalisation problems • Dry cable core • Water blocking to IEC 60794-1-F5 • UV resistant • Suitable for use outdoors and indoors • Direct burial in the ground possible
St re ng th
12
9.3
63
≤ 2700
≥ 165
≥140
2.2
24
9.3
63
≤ 2700
≥ 165
≥140
2.2
36
10.5
84
≤ 2700
≥ 185
≥160
2.2
48
10.5
84
≤ 2700
≥ 185
≥160
2.2
60
10.5
84
≤ 2700
≥ 185
≥160
2.2
Temperature range • Installation and assembly • Operation • Transport and storage
Or de rN 62 o. .5 /1 25 µm
Or de rN 50 o. /1 25 µm
Type designation
Or de rN 9/ o. 12 5µ m
Ordering information
No .o ff ib er s
14
A-DQ(ZN)H 2 x 6
12
LCXLM1-D4012-U701
LCXLM1-K4012-J701
LCXLM1-M4012-H701
A-DQ(ZN)H 4 x 6
24
LCXLM1-D4024-U701
LCXLM1-K4024-J701
LCXLM1-M4024-H701
A-DQ(ZN)H 3 x 12
36
LCXLM1-D4036-U701
LCXLM1-K4036-J701
LCXLM1-M4036-H701
A-DQ(ZN)H 4 x 12
48
LCXLM1-D4048-U701
LCXLM1-K4048-J701
LCXLM1-M4048-H701
A-DQ(ZN)H 5 x 12
60
LCXLM1-D4060-U701
LCXLM1-K4060-J701
LCXLM1-M4060-H701
–5°C to +50°C –30°C to +70°C –40°C to +70°C
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
15 2 0 0 1
MPC (Multi-Purpose Cables) Minibundle MPC A–DQ(BN)H Application FutureLink MPC (multi-purpose cables) can be used both indoors and outdoors for campus backbone and building backbone (riser) cabling. These cables are specially designed for placement in ducts, for pulling into duct systems or for direct burial.
Characteristics
24
11.3
125
≤ 4000
≥ 255
≥ 230
2.28
36
11.3
125
≤ 4000
≥ 255
≥ 230
2.28
48
11.3
125
≤ 4000
≥ 255
≥ 230
2.28
60
11.3
125
≤ 4000
≥ 255
≥ 230
2.28
Temperature range • Installation and assembly • Operation • Transport and storage
Or de rN 62 o. .5 /1 25 µm
Or de rN 50 o. /1 25 µm
Or de rN 9/ o. 12 5µ m
No .o ff ib er s
Ordering information
Type designation
Cables
No .o ff ib er s Ou ts id e di a. (m W m ei gh ) t( kg /k Te m ns ) ile in lo st a d al fo la r t Be ion (N nd ra ) in di st us al f la tio or Be n (m nd m ra ) in di us op er a Fi tion re ra (mm tin ) g (M J/ m )
Ce Sw Gl Du as nt el m sy ra la m bl lm ar y e n el em el Bu em ar em ffe be m en en or r, rt t ,m m ts ub e et e t a w al l-f ith FR -fr re NC ee e up sh t o ea 12 th fib er s, fil le d
• Low-smoke to IEC 61034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-1 and non-corrosive to IEC 60754-2 (FRNC) • Non-metallic design • No grounding or potential equalisation problems • Enhanced rodent protection • Dry cable core • Water blocking to IEC 60794-1-F5 • UV resistant • Suitable for use outdoors and indoors • Direct burial in the ground possible
A-DQ(BN)H 2 x 12
24
LCXLM1-D4024-U700
LCXLM1-K4024-J700
LCXLM1-M4024-H700
A-DQ(BN)H 3 x 12
36
LCXLM1-D4036-U700
LCXLM1-K4036-J700
LCXLM1-M4036-H700
A-DQ(BN)H 4 x 12
48
LCXLM1-D4048-U700
LCXLM1-K4048-J700
LCXLM1-M4048-H700
A-DQ(BN)H 5 x 12
60
LCXLM1-D4060-U700
LCXLM1-K4060-J700
LCXLM1-M4060-H700
–5°C to +50°C –30°C to +70°C –40°C to +70°C
C o r n i n g C a b l e
S y s t e m s
MPC (Multi-Purpose Cables) Maxibundle (Maxitube) MPC A–D(BN)H Application FutureLink MPC (multi-purpose cables) can be used both indoors and outdoors for campus backbone and building backbone (riser) cabling as well as for the horizontal cabling between the floor distributor (horizontal cross-connect) and the terminal equipment/workstations (Fiber-to-the-Desk). These cables are specially designed for placement in ducts, for pulling into duct systems or for direct burial.
Characteristics
co rd
FR NC
sh ea th
No .o ff ib er s Ou ts id e di a. (m W m ei gh ) t( kg /k Te m ns ) ile in lo st a d al fo la r t Be ion ( nd N) ra in di st us al f la tio or Be n (m nd m ra ) in di us op er a Fi tion re ra (mm tin ) g (M J/ m )
Gl fil Ma as led xi sy tu be ar n w ar ith m or up ,m to et 24 al fib -fr ee er s,
• Low-smoke to IEC 61034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-1 and non-corrosive to IEC 60754-2 (FRNC) • Non metallic design • No grounding or potential equalisation problems • Enhanced rodent protection • Water blocking to IEC 60794-1-F5 • UV resistant • Suitable for use outdoors and indoors • Direct burial in the ground possible • Small diameter
Ri p
4
7.6
55
≤ 800
≥ 170
≥ 150
0.9
6
7.6
55
≤ 800
≥ 170
≥ 150
0.9
8
7.6
55
≤ 800
≥ 170
≥ 150
0.9
12
7.6
55
≤ 800
≥ 170
≥ 150
0.9
16
9.2
78
≤ 1100
≥200
≥ 180
1.63
24
9.2
78
≤ 1100
≥ 200
≥ 180
1.63
Temperature range
Or de rN 50 o. /1 25 µm
Or de rN 9/ o. 12 5µ m
Type designation
Or de rN 62 o. .5 /1 25 µm
• Installation and assembly • Operation • Transport and storage
Ordering information No .o ff ib er s
16
A-D(BN)H 1 x 4
4
LCXLM1-D0004-U700
LCXLM1-K0004-J700
LCXLM1-M0004-H700
A-D(BN)H 1 x 6
6
LCXLM1-D0006-U700
LCXLM1-K0006-J700
LCXLM1-M0006-H700
A-D(BN)H 1 x 8
8
LCXLM1-D0008-U700
LCXLM1-K0008-J700
LCXLM1-M0008-H700
A-D(BN)H 1 x 12
12
LCXLM1-D0012-U700
LCXLM1-K0012-J700
LCXLM1-M0012-H700
A-D(BN)H 1 x 16
16
LCXLM1-D0016-U700
LCXLM1-K0016-J700
LCXLM1-M0016-H700
A-D(BN)H 1 x 24
24
LCXLM1-D0024-U700
LCXLM1-K0024-J700
LCXLM1-M0024-H700
–5°C to +50°C –20°C to +60°C –25°C to +70°C
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
17 2 0 0 1
MPC (Multi-Purpose Cables) MPC with Tight Buffers A–VB(BN)H ... TB3 FRNC Application FutureLink MPC (multi-purpose cables) can be employed both indoors and outdoors for campus backbone and building backbone (riser) cabling as well as for the horizontal cabling between the floor distributor (horizontal cross-connect) and the terminal equipment/workstations (Fiber-to-the-Desk). These cables are specially designed for placement in ducts, for pulling into duct systems or for direct burial. Being packaged in 900 mm tight buffers, the fibers can be easily connectorized with field-installable connectors.
No .o ff ib er s Ou ts id e di a. (m W m ei gh ) t( kg /k Te m ns ) ile in lo st a d al fo la r t Be ion (N nd ra ) in di st us al f la tio or Be n (m nd m ra ) in di us op er a Fi tion re ra (mm tin ) g (M J/ m )
FR NC
sh ea th
Gl 24 Ma as s y tigh xitu ar t b be n ar uffe wit Sw m h el or red u la , m fib p t bl o e e et r el s al em -fr (90 en ee 0 µm ts )
• Tight buffers with 900 µm diameter, TB3 design easy stripable • Low-smoke to IEC 61034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-1 and non-corrosive to IEC 60754-2 (FRNC) • Non-metallic design • No grounding or potential equalisation problems • Enhanced rodent protection • Water blocking to IEC 60794-1-F5 • UV resistant • Suitable for use outdoors and indoors • Direct burial in the ground possible • Small diameter • Specially suitable with fieldinstallable UniCam connectors
Temperature range • Installation and assembly • Operation • Transport and storage
–5°C to +50°C –30°C to +70°C –30°C to +70°C
4
12.4
153
≤ 1500 N
≥ 250
≥ 200
1.1
6
12.4
153
≤ 1500 N
≥ 250
≥ 200
1.2
8
12.4
153
≤ 1500 N
≥ 250
≥ 200
1.3
12
12.4
153
≤ 1500 N
≥ 250
≥ 200
1.5
24
14.4
192
≤ 1500 N
≥ 260
≥ 210
1.9
Or de rN 62 o. .5 /1 25 µm
Or de rN 50 o. /1 25 µm
Or de rN 9/ o. 12 5µ m
Type designation
No .o ff ib er s
Ordering information
A-VB(BN)H 1 x 4... TB3
4
LCXLM2-G0004-U700
LCXLM2-M0004-J700
LCXLM2-N0004-H700
A-VB(BN)H 1 x 6... TB3
6
LCXLM2-G0006-U700
LCXLM2-M0006-J700
LCXLM2-N0006-H700
A-VB(BN)H 1 x 8... TB3
8
LCXLM2-G0008-U700
LCXLM2-M0008-J700
LCXLM2-N0008-H700
A-VB(BN)H 1 x 12... TB3
12
LCXLM2-G0012-U700
LCXLM2-M0012-J700
LCXLM2-N0012-H700
A-VB(BN)H 1 x 24... TB3 24
LCXLM2-G0024-U700
LCXLM2-M0024-J700
LCXLM2-N0024-H700
Cables
Characteristics
C o r n i n g C a b l e
S y s t e m s
Indoor Cables Indoor Maxibundle (Maxitube) Cables J–DH Application FutureLink provides all the FO products required for installing campus backbone and building backbone (riser) cabling as well as for the horizontal cabling between the floor distributor (horizontal cross-connect) and the terminal equipment/workstations (Fiber-to-the-Desk). The indoor maxibundle cables are particularly suitable for placing and pulling into cable conduits and shafts inside buildings.
Characteristics
w ith
tu be
St re ng th
FR NC
No .o ff ib er s Ou ts id e di a. (m W m ei gh ) t( kg /k Te m ns ) ile in lo st a d al fo la r t Be ion ( nd N) ra in di st us al f la tio or Be n (m nd m ra ) in di us op er a Fi tion re ra (mm tin ) g (M J/ m )
sh ea m th em be rs up ,m to et 12 al -fr fib ee er s, fil le d
• Low-smoke to IEC 61034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-1 and non-corrosive to IEC 60754-2 (FRNC) • Non-metallic design • No grounding or potential equalisation problems • Small diameter • Low weight • Low fire load rating
4
6.2
41
≤ 400
≥ 140
≥ 125
0.76
6
6.2
41
≤ 400
≥ 140
≥ 125
0.76
8
6.2
41
≤ 400
≥ 140
≥ 125
0.76
12
6.2
41
≤ 400
≥ 140
≥ 125
0.76
Ri p
co rd
Bu ffe r Fi be r
Temperature range • Installation and assembly • Operation • Transport and storage
Or de rN 62 o. .5 /1 25 µm
Or de rN 50 o. /1 25 µm
Type designation
Or de rN 9/ o. 12 5µ m
Ordering information
No .o ff ib er s
18
J-DH 1 x 4
4
LCXLI1-D0004-U700
LCXLI1-K0004-J700
LCXLI1-M0004-H700
J-DH 1 x 6
6
LCXLI1-D0006-U700
LCXLI1-K0006-J700
LCXLI1-M0006-H700
J-DH 1 x 8
8
LCXLI1-D0008-U700
LCXLI1-K0008-J700
LCXLI1-M0008-H700
J-DH 1 x 12
12
LCXLI1-D0012-U700
LCXLI1-K0012-J700
LCXLI1-M0012-H700
–5°C to +50°C –20°C to +60°C –25°C to +70°C
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
19 2 0 0 1
Indoor Cables Indoor Minibundle Cables J–DH Application FutureLink provides all the FO products required for installing campus backbone and building backbone (riser) cabling as well as for the horizontal cabling between the floor distributor (horizontal cross-connect) and the terminal equipment/workstations (Fiber-to-the-Desk). The indoor minibundle cables are particularly suitable for placing and pulling into cable conduits and shafts inside buildings, in order to connect distributors with high fiber counts.
Characteristics
Bu ffe r
24
7.8
54
≤ 1000
≥ 140
≥120
1.2
36
9.0
71
≤ 1000
≥ 160
≥ 140
1.7
48
9.0
71
≤ 1000
≥ 160
≥ 140
1.6
60
9.0
71
≤1000
≥ 160
≥ 140
1.5
72
9.5
84
≤ 1000
≥ 170
≥ 145
1.8
96
11.2
116
≤ 1000
≥ 195
≥ 170
2.1
120
12.7
152
≤ 1000
≥ 225
≥ 190
2.4
144
14.5
200
≤ 1000
≥ 255
≥ 225
2.6
Temperature range
Or de rN 50 o. /1 25 µm
Or de rN 9/ o. 12 5µ m
No .o ff ib er s
Or de rN 62 o. .5 /1 25 µm
• Installation and assembly • Operation • Transport and storage
Ordering information
Type designation
Cables
No .o ff ib er s Ou ts id e di a. (m W m ei gh ) t( kg /k Te m ns ) ile in lo st a d al fo la r t Be ion (N nd ra ) in di st us al f la tio or Be n (m nd m ra ) in di us op er a Fi tion re ra (mm tin ) g (M J/ m )
Ce Du FR nt NC m ra m sh lm tu y e el be a em em t h w b en ith er , t up m et to a l-f 12 re fib e er s, fil le d
• Low-smoke to IEC 61034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-1 and non-corrosive to IEC 60754-2 (FRNC) • Non-metallic design • No grounding or potential equalisation problems • Small diameter • Low weight • Low fire load rating
J-DH 4 x 6
24
LCXLI1-D4024-U700
LCXLI1-K4024-J700
LCXLI1-M4024-H700
J-DH 3 x 12
36
LCXLI1-D4036-U700
LCXLI1-K4036-J700
LCXLI1-M4036-H700
J-DH 4 x 12
48
LCXLI1-D4048-U700
LCXLI1-K4048-J700
LCXLI1-M4048-H700
J-DH 5 x 12
60
LCXLI1-D4060-U700
LCXLI1-K4060-J700
LCXLI1-M4060-H700
J-DH 6 x 12
72
LCXLI1-D4072-U700
LCXLI1-K4072-J700
LCXLI1-M4072-H700
J-DH 8 x 12
96
LCXLI1-D4096-U700
LCXLI1-K4096-J700
LCXLI1-M4096-H700
J-DH 10 x 12
120
LCXLI1-D4120-U700
LCXLI1-K4120-J700
LCXLI1-M4120-H700
J-DH 12 x 12
144
LCXLI1-D4144-U700
LCXLI1-K4144-J700
LCXLI1-M4144-H700
–5°C to +50°C –20°C to +60°C –25°C to +70°C
C o r n i n g C a b l e
S y s t e m s
Indoor Cables Multifiber Indoor Cables (MIC) J–VH... TB3 FRNC Application The multifiber indoor cables are particularly suitable for placing and pulling into cable conduits and shafts (building backbone and horizontal subsystems) and as connection cable between distributors and to connect workstations inside buildings (FttD). They can also be used as inter-building cables laid in dry conduits.
Characteristics
St re ng th
No .o ff ib er Ou s ts id e di a. W (m ei gh m t( ) kg Te / km ns ile ) in lo st ad al fo la r t Be ion (N nd ra ) in di st us al f la tio or Be n ( nd m m ra ) in di us op er a Fi tion re ra (mm tin g ) (M J/ m )
Ce Ti gh nt tb ra lm uf fe m em r em be be r, rs m ,m et al et -fr al -fr ee ee
• Especially suitable with field-installable UniCam connectors • Low-smoke to IEC 61034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-3 and non-corrosive to IEC 60754-2 (FRNC) • Non-metallic design • No grounding or potential equalisation problems • Tight buffers of 900 µm diameter (TB3) • Dry
sh ea th Ri p
co rd
FR NC
2
4.5
20
≤ 800
≥ 80
≥ 70
0.33
4
5.1
23
≤ 1000
≥ 95
≥ 80
0.50
6
5.4
27
≤ 1000
≥ 95
≥ 85
0.56
8
6.1
36
≤ 1000
≥ 105
≥ 90
0.62
12
7.4
56
≤ 1800
≥ 125
≥ 100
0.84
16
8.3
75
≤ 2000
≥ 145
≥ 125
1.07
24
10.6
124
≤ 2700
≥ 190
≥ 160
1.40
Temperature range • Installation and assembly • Operation • Transport and storage
Or de rN 62 o. .5 /1 25 µm
Or de rN 50 o. /1 25 µm
Type designation
Or de rN 9/ o. 12 5µ m
Ordering information
No .o ff ib er s
20
J-VH 2
2
LCXLI2-D1002-U700
LCXLI2-L1002-J700
LCXLI2-M1002-H700
J-VH 4
4
LCXLI2-D1004-U700
LCXLI2-L1004-J700
LCXLI2-M1004-H700
J-VH 6
6
LCXLI2-D1006-U700
LCXLI2-L1006-J700
LCXLI2-M1006-H700
J-VH 8
8
LCXLI2-D1008-U700
LCXLI2-L1008-J700
LCXLI2-M1008-H700
J-VH 12
12
LCXLI2-D1012-U700
LCXLI2-L1012-J700
LCXLI2-M1012-H700
J-VH 16
16
LCXLI2-D1016-U700
LCXLI2-L1016-J700
LCXLI2-M1016-H700
J-VH 24
24
LCXLI2-D1024-U700
LCXLI2-L1024-J700
LCXLI2-M1024-H700
–5°C to +50°C –20°C to +60°C –25°C to +70°C
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
21 2 0 0 1
Indoor Cables Breakout Cables T-VHH... TB3 FRNC Application The breakout cables are particularly suitable for placing and pulling into cable conduits and shafts (building backbone and horizontal subsystems), as connection cable between distributors and to connect workstations inside buildings (FttD). They can also be used as inter-building cables laid in dry conduits. The basic elements offer additional protection to the individual buffers.
fo r
m )
3.9 x 6.8
30
≥ 70
≥ 60
0.52
≥ 400
4
8.9
75
≥ 160
≥ 135
1.27
≥ 800
6
10.7
108
≥ 190
≥ 165
1.88
≥ 1200
8
12.5
150
≥ 220
≥ 190
2.64
≥ 1600
12
16.4
260
≥ 285
≥ 245
4.61
≥ 2400
Or de rN 62 o. .5 /1 25 µm
• Installation and assembly • Operation • Transport and storage
Or de rN 50 o. /1 25 µm
Or de rN 9/ o. 12 5µ m
No .o ff ib er s
Type designation
n tio la l a st in
2
Temperature range
Ordering information
lo ad
(M J/
ra tin g
Fi re
in
n tio ra e op
) m (m
Te ns ile
No .o ff ib er s Ou ts id e di a. (m m W ) ei gh t( kg /k Be m nd ) ra in di st us al fo la r t Be ion nd (m m ra ) di us
Ce Ti St Ba gh re nt sic ng tb ra ele t lm u h m ffe m en em FR r e to m NC be be f2 r, ou rs .9 m ,m te m et rs m al e t h -fr a d Ri ea i l a ee p f m t r h co e e e te rd r
• Especially suitable with field-installable UniCam connectors • Low-smoke to IEC 1034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-3 and non-corrosive to IEC 60754-2 (FRNC) • Non-metallic design • No grounding or potential equalisation problems • Basic element of 2.9 mm diameter with additional strength members T-VHH cables are also available with basic elements of 2.2 mm diameter • Dry • Tight buffers of 900 µm diameter (TB3)
T-VHH 2
2
LCXLI2-D3002-U720
LCXLI2-L3002-J720
LCXLI2-M3002-H720
T-VHH 4
4
LCXLI2-D3004-U720
LCXLI2-L3004-J720
LCXLI2-M3004-H720
T-VHH 6
6
LCXLI2-D3006-U720
LCXLI2-L3006-J720
LCXLI2-M3006-H720
T-VHH 8
8
LCXLI2-D3008-U720
LCXLI2-L3008-J720
LCXLI2-M3008-H720
T-VHH 12
12
LCXLI2-D3012-U720
LCXLI2-L3012-J720
LCXLI2-M3012-H720
–5°C to +50°C –20°C to +60°C –25°C to +70°C
] [N
Cables
Characteristics
C o r n i n g C a b l e
S y s t e m s
Indoor Cables Simplex and Duplex Cord J–VH... TB3 FRNC Application The simplex and duplex cords are particularly suitable for placing and pulling into cable raceways, as patch and connection cords. These cords are also used by assembly houses for making patch cords and cable pigtails.
Characteristics
FR NC
W ei gh t( kg /
km ) Te ns ile in lo st ad al f la tio or Be n (N nd ra ) in di st us al f la tio or Be n (m nd m ra ) in di us op er at io n (m m )
di a. (m m ) Ou ts id e
sh ea th
m em be rs ,m et al -fr ee
No .o ff ib er s
Ti gh tb uf fe r9 00
µm
• Especially suitable with field-installable UniCam connectors • Low-smoke to IEC 61034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-3 and non-corrosive to IEC 60754-2 (FRNC) • Dry • Tight buffers of 900 µm diameter (TB3) • Basic element of 2.9 mm diameter with additional strength members simplex and duplex cords are also available with basic elements of 2.2 mm diameter
St re ng th
1
2.9
9
≤ 200
≥ 50
≥ 45
2
2.9 x 5.8
16
≤ 400
≥ 50
≥ 45
Temperature range • Installation and assembly • Operation • Transport and storage
Or de rN 62 o. .5 /1 25 µm
Or de rN 50 o. /1 25 µm
Type designation
Or de rN 9/ o. 12 5µ m
Ordering information
No .o ff ib er s
22
J-VH 1
1
LCXLI2-D2001-U720
LCXLI2-L2001-J720
LCXLI2-M2001-H720
J-VH 2 x 1
2
LCXLI2-D2002-U720
LCXLI2-L2002-J720
LCXLI2-M2002-H720
Sheath color: Green
Sheath color: Blue
LCXLI2-L2002-J721
LCXLI2-M2002-H721
Special colors J-VH 2 x 1
2
–5°C to +50°C –20°C to +60°C –25°C to +70°C
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
23 2 0 0 1
Indoor Cables Tight Buffer V–E9/G50/G62.5 Application Pigtails, made out of tight buffers, are used for the connection between patch panel front and splice trays, where they are spliced to the incoming or outgoing cables. As the pigtails are protected by the patch panel box, it is possible to use 900 µm or 700 µm tight buffers instead of cable pigtails. These tight buffers are used mainly by assembly houses to make pigtails.
le n Be gth [m nd ] ra in di st us al fo la r t Be ion (m nd m ra ) in di us op er at io n (m m )
st ep
st rip
On e
W ei gh t( kg /
km )
di a. (m m ) Ou ts id e
No .o ff ib er s
µm
or 70 0
µm
di Ja am ck et et o er f
90 0
Fi be r1 25 /
25 0
µm
• Low-smoke to IEC 61034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-3 and non-corrosive to IEC 60754-2 (FRNC) • Without filling component (Dry) • Easily strippable (TB for 900 µm and TB3 for 700 µm)
1
0.9
1
≤ 1.5
≥ 30
≥ 30
1
0.7
1
≤ 0.15
≥ 30
≥ 30
TB Tight buffer up to 1.5 m strippable TB3 Tight buffer up to 150 mm strippable
Or de rN 50 o. /1 25 µm
co lo r Bu ffe r
Type designation
Fi be rt yp e
Ordering information
V-E9 (900 µm)
9/125 µm
Yellow
LCXLI2-EX001-U700-GE
V-G50 (900 µm)
50/125 µm
Green
LCXLI2-LX001-J700-GN
V-G62.5 (900 µm)
62.5/125 µm
Blue
LCXLI2-MX001-H700-BL
V-E9 R (700 µm)
9/125 µm
Yellow
LCXLI2-EX001-U701-GE
V-G50 R (700 µm)
50/125 µm
Green
LCXLI2-LX001-J701-GN
V-G62.5 R (700 µm)
62.5/125 µm
Blue
LCXLI2-MX001-H701-BL
Cables
Characteristics
C o r n i n g C a b l e
S y s t e m s
Indoor Cables MiniMIC J–VH2 TB3 R FRNC Application The MiniMIC is particularly suitable for making patch and connection cords for use inside buildings. It is primarily used for termination of two-fiber connectors (MT-RJ) by assembly houses.
Characteristics
Ti gh tb uf fe m r7 em 00 be r, µm di el ec tr ic
No .o ff ib er s Ou ts id e di a. W (m ei m gh ) t( kg /k Te m ns ) ile in lo st a d al fo la r ti Be on (N nd ra ) in di st us al f la tio or Be n (m nd m ra ) in di us op er a Fi tion re ra (mm tin ) g (M J/ m )
• Low-smoke to IEC 61034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-3 and non-corrosive to IEC 60754-2 (FRNC) • Non-metallic design • Tight-buffered fiber of 700 µm diameter (TB3) • Dry
2
2.9
8
≤ 200
≥ 50
≥ 45
Temperature range
sh ea th
St re ng th
• Installation and assembly • Operation • Transport and storage
FR NC
2
LCXLI2-G1002-U701
LCXLI2-M1002-J701
Or de rN 62 o. .5 /1 25 µm
J-VH2 TB3 R
Or de rN 50 o. /1 25 µm
Type designation
Or de rN 9/ o. 12 5µ m
Ordering information
No .o ff ib er s
24
LCXLI2-M1002-H701
–5°C to +50°C –20°C to +60°C –25°C to +70°C
0.2
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
25 2 0 0 1
Indoor Cables MiniZip J–VH 2x1 TB3 R FRNC Application The MiniZip is particularly suitable for making adapter and connection cords for the use inside buildings. It is primarily used by assembly houses for terminating multifiber connectors (MT-RJ) in combination with single-fiber connectors.
Ti gh tb uf fe r7 00
µm
No .o ff ib er Ou s ts id e di a. (m m W ) ei gh t( kg Te /k ns m ile ) in lo st a d al fo la Be tion r nd ( ra N) in di st u al sf la o Be tion r nd (m ra in di m) us op er Fi atio re ra n (m tin m g ) (M J/ m )
• Low-smoke to IEC 61034 and zero-halogen (LS0H) • Flame-retardant to IEC 60 332-3 and non-corrosive to IEC 60754-2 (FRNC) • Non-metallic design • Tight-buffered fiber of 700 µm diameter (TB3) • Dry
1.8 x 3.6
6
≤ 150
• Installation and assembly • Operation • Transport and storage
J-VH 2x1 TB3 R
2
LCXLI2-G2002-U740
LCXLI2-M2002-J740
Or de rN 62 o. .5 /1 25 µm
Or de rN 50 o. /1 25 µm
Or de rN 9/ o. 12 5µ m
No .o ff ib er s
Ordering information
Type designation
≥ 40
≥ 30
0.25
Temperature range
St re ng th
FR NC
sh ea th
m em be rs ,m et al -fr ee
2
LCXLI2-M2002-H740
–5°C to +50°C –20°C to +60°C –25°C to +70°C
Cables
Characteristics
26
C o r n i n g C a b l e
S y s t e m s
Pre-assembled Multifiber Cables MPC (Multi-Purpose Cables) Order Number Scheme
Order Examples
Cable type
Maxibundle MPC A-D(BN)H...
MPC A-D(BN)H
LCALMA -
-
up to 24 fibers Single-mode 9/125 µm
A
Multimode 50/125 µm
B
Length in m
Multimode 62.5/125 µm
C
upon request
Fiber count 4
0 4
6
0 6
8
0 8
12
1
2
16
1
6
24
2 4
A end Connector Connector type*
Order No.: LCALMA-B1222-0080
E end Connector 0 = none
1 = ST
1 = ST
2 = SC
2 = SC
3 = SC duplex 4 = MT-RJ (no pin) 5 = MT-RJ (pins)
Pre-assembled MPC A-D(BN)H 1X12G50/125 2.5B400 + 0.7F1200, 80 m long, zero-halogen, 50 µm fiber, non-metallic rodent protection, both ends terminated with 12 SC connectors
3 = SC duplex
Pre-assembled MPC A-D(BN)H 1X8G62.5/125 3.1B200 + 0.8F600, 1250 m long, zero-halogen, 62.5 µm fiber, non-metallic rodent protection, E end terminated with 8 ST connectors and A end terminated with 4 MT-RJ connectors with pins
4 = MT-RJ (no pin) 5 = MT-RJ (pins)
* When generating the order number the higher number of connector type is followed by the lower on
The assembled multifiber cables are supplied as standard with a leg length of 0.75 m and a pulling grip at each end. If there are more than 4 fibers, the ends are stepped in 4 cm increments (2 fibers each).
Order No.: LCALMA-C0851-1250
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
27 2 0 0 1
Pre-assembled Multifiber Cables MPC with Tight Buffers (Multi-Purpose Cables) Order Number Scheme
Order Examples Tight buffer MPC A-VB(BN)H...
Cable type MPC with tight buffers (TB 3) LCALMH -
-
A-VB(BN)H up to 24 fibers Single-mode 9/125 µm
A
Length in m
Multimode 50/125 µm
B
upon request
Multimode 62.5/125 µm
C 0 4
6
0 6
8
0 8
12
1
2
16
1
6
24
2
4
A end Connector
Order No.: LCALMH-B2411-0070
E end Connector 0 = none
Connector type*
1 = ST
1 = ST
2 = SC
2 = SC
3 = SC duplex 4 = MT-RJ (no pin) 5 = MT-RJ (pins)
3 = SC duplex 4 = MT-RJ (no pin) 5 = MT-RJ (pins)
* When generating the order number the higher number of connector type is followed by the lower on
The assembled multifiber cables are supplied as standard with a leg length of 0.75 m and a pulling grip at each end. If there are more than 4 fibers, the ends are stepped in 4 cm increments (2 fibers each).
Pre-assembled MPC A-VB(BN)H 1X6G62.5/125 3.1B200 + 0.8F600, TB3 FRNC, 1550 m long, zero-halogen, 62.5 µm fiber, non-metallic rodent protection, A end terminated with 3 SC duplex connectors and E end terminated with 3 MT-RJ connectos with pins Order No.: LCALMH-C0653-1550
Pre-assembled Cables
Fiber count 4
Pre-assembled MPC with tight buffers, A-VB(BN)H 1X24G50/125 2.7B400 + 0.8F1200, TB3 FRNC, 70 m long, zero-halogen, 50 µm fiber, non-metallic rodent protection, both ends terminated with 24 ST connectors
28
C o r n i n g C a b l e
S y s t e m s
Pre-assembled Multifiber Cables Multifiber Indoor Cables (MIC) Order Number Scheme
Order Examples
Cable type
Multifiber indoor cable J-VH...TB3 FRNC
MIC J-VH
LCALIG -
-
(Tight-buffers of 900 µm diameter)
up to 24 fibers Single-mode 9/125 µm
A
Multimode 50/125 µm
B
Length in m
Multimode 62.5/125 µm
C
upon request
Fiber count 2
0 2
4
0 4
6
0 6
8
0 8
12
1
2
16
1
6
24
2
4
A end Connector Connector type*
Order No.: LCALIG-C0421-0040
E end Connector 0 = none
1 = ST
1 = ST
2 = SC
2 = SC
3 = SC duplex 4 = MT-RJ (no pin) 5 = MT-RJ (pins)
Pre-assembled MIC J-VH 4G62.5/125 3.1B200 + 0.8F600, TB3 FRNC, 40 m long, zero-halogen, 62.5 µm fiber, A end terminated with 4 SC connectors and E end terminated with 4 ST connectors
3 = SC duplex 4 = MT-RJ (no pin) 5 = MT-RJ (pins)
* When generating the order number the higher number of connector type is followed by the lower on
The assembled multifiber cables are supplied as standard with a leg length of 0.75 m and a pulling grip at each end. If there are more than 4 fibers, the ends are stepped in 4 cm increments (2 fibers each).
Pre-assembled MIC J-VH 24E9/ 125 0.38F3.5 + 0.25H18, TB3 FRNC, 1010 m long, zero-halogen, 9 µm fiber, E end terminated with 12 SC duplex connectors and A end terminated with 12 MT-RJ connectors with pins Order No.: LCALIG-A2453-1010
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
29 2 0 0 1
Pre-assembled Multifiber Cables Breakout Cables Order Number Scheme
Order Examples
Cable type
Breakout cable T-VHH...
Breakout
(basic elements of 2.9 mm diameter) LCALIF -
-
up to 24 fibers Single-mode 9/125 µm
A
Multimode 50/125 µm
B
Length in m
Multimode 62.5/125 µm
C
upon request
Fiber count 2
0 2
4
0 4
6
0 6
8
0 8
12
1
Pre-assembled breakout cable T-VHH 6G50/125 2.7B400 + 0.8F1200 TB3 FRNC, 50 m long, zero-halogen, orange, 50 µm fiber, both ends terminated with 3 SC duplex connectors Order No.: LCALIF-B0633-0050
2
A end Connector
E end Connector 0 = none
Connector type* 1 = ST
1 = ST
2 = SC
2 = SC
3 = SC duplex 4 = MT-RJ (no pin) 5 = MT-RJ (pins)
3 = SC duplex 4 = MT-RJ (no pin) 5 = MT-RJ (pins)
* When generating the order number the higher number of connector type is followed by the lower on
The assembled multifiber cables are supplied as standard with a leg length of 0.75 m and a pulling grip at each end. If there are more than 4 fibers, the ends are stepped in 4 cm increments (2 fibers each).
Pre-assembled breakout cable T-VHH 2E9/125 0.38F3.5 + 0.25H18 TB3 FRNC, 90 m long, zero-halogen, yellow, 9 µm fiber, both ends terminated with 2 ST connectors Order No.: LCALIF-A0211-0090
Pre-assembled Cables
T-VHH
30
C o r n i n g C a b l e
S y s t e m s
Cable Pigtails and Patch Cords Simplex Cords Order Number Scheme
Ordering Examples Simplex cords
Simplex cords Cable pigtails and
1 2 3 4 5 6
patch cords
LCALI2-
8
9
10
11
12
14
15
16
17
-
Single-mode 9/125 µm
A
Multimode 50/125 µm
B
Multimode 62.5/125 µm
C
Length in dm (last 3 digits) A... 005 to 990 dm B... 1000 to 1990 dm
J-VH 1G50/125 2.7B400 + 0.8F1200 TB3 FRNC, 3 m long, zero-halogen, orange, 50 µm fiber, outside end: 1 x SC connector, inside end: 1 x ST connector.
C... 2000 to 2990 dm Basic element:
D... 3000 to 3990 dm
Simplex 2.9 mm Tight buffer type
1)
TB
2)
TB3
1
up to 3 m in 0.5 m steps;
3
more than 3 m up to 10 m in 1.0 m steps; other length upon request
A end Connector
2)
TB TB3
E end Connector 0 = none
Connector type*
1)
Order No.: LCALI2-B1321-A030
1
1 = ST
1 = ST
2 = SC
2 = SC
Tight buffer up to 1.5 m strippable Tight buffer up to 150 mm strippable
For cable pigtails tight buffer type TB are recommended. For patch cords tight buffer type TB3 are recommended. * When generating the order number the higher number of connector type is followed by the lower on
Cable pigtails and patch cords with PVC tight buffers (TB2) and PVC sheath are available upon request. Further fiber and connector types are available upon request.
J-VH 1G62.5/125 3.2B200 + 0.8F600 TB3 FRNC 5 m long, zero-halogen, orange, 62.5 µm fiber, both ends terminated with ST connector. Order No.: LCALI2-C1311-A050
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
31 2 0 0 1
Cable Pigtails and Patch Cords Duplex Cords Order Examples
Order Number Scheme
Duplex cords
Duplex cords Cable pigtails and
1 2 3 4 5 6
patch cords
LCALI2-
8
9
10
11
12
14
15
16
17
-
Single-mode 9/125 µm
A
Multimode 50/125 µm
B
Multimode 62.5/125 µm
C
Length in dm (last 3 digits) A... 005 to 990 dm B... 1000 to 1990 dm C... 2000 to 2990 dm D... 3000 to 3990 dm
Basic element: Duplex (Zipcord) 2.9 mm 1)
TB
2)
Order No.: LCALI2-B2321-A015
2
TB3
1
up to 3 m in 0.5 m steps;
3
more than 3 up to 10 m in 1.0 m steps; other length upon request
A end Connector 1 = ST
1 = ST
2 = SC
2 = SC
3 = SC duplex
2)
TB TB3
Connector 0 = none
Connector type*
1)
E end
J-VH 2 x 1G62.5/125 3.2B200 + 0.8F600 TB3 FRNC 20 m long, zero-halogen, orange, 62.5 µm fiber, E end: 2 x ST connectors, A end: SC duplex connector.
3 = SC duplex
Tight buffer up to 1.5 m strippable Tight buffer up to 150 mm strippable
For cable pigtails tight buffer type TB are recommended. For patch cords tight buffer type TB3 are recommended. * When generating the order number the higher number of connector type is followed by the lower on
Cable pigtails and patch cords with PVC tight buffers (TB2) PVC and sheath are available upon request. Further fiber and connector types are available upon request. Standard duplex patch cords are reversed in polarity (transmitter to receiver).
Order No.: LCALI2-C2331-A200
Pre-assembled Cables
Tight buffer type
J-VH 2 x 1G50/125 2.7B400 + 0.8F1200 TB3 FRNC, 1.5 m long, zero-halogen, orange, 50 µm fiber, A end: 2 x SC connectors, E end: 2 x ST connectors.
32
C o r n i n g C a b l e
S y s t e m s
Cable Pigtails and Patch Cords with MT-RJ Connectors Order Number Scheme Cable pigtails and
1 2 3 4 5 6
patch cords
LCALI2-
8
9
10
11
12
14
15
16
17
-
Single-mode 9/125 µm
A
Multimode 50/125 µm
B
Multimode 62.5/125 µm
C
Length in dm (last 3 digits) A... 005 to 990 dm B... 1000 to 1990 dm C... 2000 to 2990 dm
Basic element:
D... 3000 to 3990 dm
Duplex (Zipcord)
5
for hybrid version
up to 3 m in 0.5 m steps;
Duplex (2 fiber MIC)
Terminated MT-RJ plugs Permanently installed cables are normally provided with pins at both ends. Patch cords do not have pins because the active components always contain pins.
7
On the stated standard MT-RJ patch cords connectorized at both ends the polarity is reversed (transmitter to receiver).
more than 3 up to 10 m
for MT-RJ both ends
in 1.0 m steps; other length upon request
Tight buffer type
1)
TB3
3
A end Connector Connector type*
Order Examples E end Connector 0 = none
1 = ST
1 = ST
2 = SC
2 = SC
3 = SC duplex 4 = MT-RJ (no pin) 5 = MT-RJ (pins)
3 = SC duplex 4 = MT-RJ (no pin)
J-VH 2 x 1G50/125 2.7B400 + 0.8F1200 TB3 FRNC, 5 m long, zero-halogen, orange, 50 µm fiber, E end: 2 x SC connectors, A end: MT-RJ connector without pins.
5 = MT-RJ (pins)
Order No.: LCALI2-B5342-A050 1)
TB3
Tight buffer insulation FRNC up to 150 mm strippable
* When generating the order number the higher number of connector type is followed by the lower on
J-VH 2G62.5/125 3.2B200 + 0.8F600 TB3 FRNC 220 m long, zero-halogen, orange, 62.5 µm fiber, both side terminated with MT-RJ connector with pins Order No.: LCALI2-C7355-C200
Cable pigtails and patch cords with PVC tight buffers (TB2) and PVC sheath are available upon request. Further fiber and connector types are available upon request.
F u t u r e L i n k
M o d u l a r - S y s t e m
C a t a l o g I s s u e
33 2 0 0 1
Pigtails Order Examples
Order Number Scheme
Pigtail 1 2 3 4 5 6
8
9
10
11
LCALI2-
Pigtails
12
14
15
16
17
-
Single-mode 9/125 µm
A
Multimode 50/125 µm
B
A ... 005 to 990 dm
Length in dm (last 3 digits)
Multimode 62.5/125 µm
C
B ... 1000 to 1990 dm
V-E9/125 0.38F3.5 + 0.25H18 TB, 2 m long; zero-halogen; single-mode fiber, A end: SC connector Order No.: LCALI2-A3120-A020
up to 3 m in 0.5 m steps;
Tight Buffer type: 3
Pigtail buffer 900 µm (for
other length upon request
ST & SC connectors only)
V-G62.5/125 3.2B200 + 0.8F600 TB, 50 cm long; zero-halogen; 62.5 µm fiber, A end: MT-RJ connector with pins.
6
Pigtail buffer 700 µm (for MT-RJ connectors only) Tight buffer type
1)
1
TB
Order No.: LCALI2-C6150-A005
1 = ST 2 = SC 3 = SC duplex 4 = MT-RJ (no pin) 5 = MT-RJ (pins) TB
Connector 0 = none
Connector type
1)
E end
Tight buffer up to 1.5 m strippable
Further fiber and connector types are available on request.