Preview only show first 10 pages with watermark. For full document please download

19cali Patch Panel, 24 X Rj445, Cable Organizer, System Cat 5e

   EMBED


Share

Transcript

www.bkte.pl System cat. 5e, class D - 100 MHz, shielded Product information 19" Patch Panel, 24 x RJ445, cable organizer Patch panels serve as terminals for wire cables laid vertically or horizontally and function as a connecting point for active equipment working within a network. All elements feature high quality transmission and mechanical parameters. 19 Inch (482,6±0,3) C5e 3 2 1 5 4 6 9 8 7 10 12 11 14 13 15 17 16 21 20 19 18 22 6,5±0,2 31,8±0,2 44,0±0,2 464,8±0,3 24 23 11,5±0,2 440,0±0,2 7 6 4 5 1 2 3 109,0±0,2 9 7 10 8 8 7 11 7 12 8 8 7 8 7 13 7 8 7 14 8 15 7 8 7 16 8 8 7 8 7 17 7 8 7 18 8 8 7 19 7 20 8 8 7 8 7 21 7 8 7 22 8 8 7 23 7 8 7 24 8 8 8 7 8 7 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Features Mechanical parameters Ÿ Patch panels designed in 19” standard with a height of 1U, Ÿ Integrated cabling shelf for securing cables using cable ties, Ÿ 24 shielded RJ45 ports, Ÿ Slot connection IDC LSA for cables with AWG 22 - AWG 26, Ÿ Color-coded terminals according to T568A and T568B schemes, Ÿ Earthing cord. Ÿ Housing: galvanized steel tin plated (SECC) 1.2mm thick, powder Conformity to respective requirements in norms Ÿ PN-EN-50173-1:2007 Ÿ EN 50173-1:2007 Ÿ EN 50173-1:2007/A1 Ÿ TIA/EIA-568-B.2 Ÿ ISO/IEC 11801 2002 Ÿ ISO/IEC 11801 2002/Amd 1:2008/Cor 1:2008 Ÿ ISO/IEC 61156-5 (2009-02) Ed.2.0. painted in black, Ÿ RJ45 terminal housing: Poli tereftalato butylene (PBT) UL94V-0, Ÿ RJ45 terminal shield: Bronze nickel plated, Ÿ RJ45 jack finish and contact material: - Phosphor bronze, - 1.2 µm gold plated on 1.2 µm - 1.5 µm nickel layer. Ÿ IDC housing: PC+5%GF, UL 94V-2, Ÿ Durability: - Jack: 750 cycles plug-jack mating and unmating test, insertion cycles at 20 cycles/minute max. contact resistance test per 100 cycles, - IDC: max. 200 punching times. Ÿ Insertion force: RJ45 < 9 N, Ÿ Retention strength: RJ45 > 75 N, Ÿ Operation temperature: -40°C to 80°C. Index: 11301111.2 This Specification is the property of BKT Elektronik and is protected by copyright law. Every effort is made to ensure that accuracy of this information. However, BKT Elektronik cannot warrant that the specification is error-free, nor can it accept responsibilities for errors. The information contained in this specification is subject to change without notice and does not represent a commitment on final product. 1/1 Contact BKT Elektronik Export Department 69 Łochowska Str. 86-005 Białe Błota tel. +48 52 36 36 371, -772, -780 fax. +48 52 36 36 370 e-mail: [email protected]