1Bay SAS/SATA II Backplane BKP-SAS3-1-AR Instruction Guide Document Number: BPD-000007-A P/N: TW-000-51712-NR Instructions Manual Descriptions: The BACKPLANE is design for 1Bay SAS 3.0G HDD Backplane, Backward compatible to SATA I/II. Build-in Power LED, HDD Access LED and HDD Fail LED. Specifications: Host Interface SAS/SATA II HDD Interface SAS/SATA Hot-swap Yes, allows user to on line replace HDD Display Power LED-Blue (When HDD is present) Access LED-Blue (Drive by HDD or controller) HDD Fail LED-Red (Drive by controller) Cooling NA Environment Monitor NA Alarm System NA Connectors SATA 7pin x 2 SATA 7+7+15 pin x 1 (for HDD) Standard 4P Power connector x 1 for +5V and +12V from power supply Pin header 2 x 4 for Enable WD. HDD Access LED Dimension 91.7 (L) x 23.5 (W) x 2.4 (H)mm Material FR4 4 Layer Document Number: BPD-000007-A P/N: TW-000-51712-NR 1 Host Connector Side HDD Slot Side D2: Power LED Turn on when HDD has been installed D3: HDD Access and HDD Fail LED ( Blue/Red dual color ) Blue LED flashing when HDD is Accessing Red LED turn on when HDD Fail Input pin (JP1 pin2) is Low level J2: SAS HDD Port A and/or SATA HDD Port J3: SAS HDD Port B JP1[1,3,5]: External LED for bi-color LED Pin 1 – Fail LED(-)_Red LED Pin 3 – LED(+) Pin 5 – Access LED(-)_Blue LED JP1[2]: HDD fail input (Active Low) JP1[4]: GND JP1[6]: HDD Access LED input (Active Low) JP1[7,8][9,10]: HDD Type select 7,8 – Close SATA HDD 9,10 – Close SAS HDD If set to wrong HDD type the HDD Access LED will Active in reverse status Document Number: BPD-000007-A P/N: TW-000-51712-NR 2