Preview only show first 10 pages with watermark. For full document please download

1w Dc-dc Converter P1c-series - Hy-line

   EMBED


Share

Transcript

1W DC-DC Converter P1C-Series ● ● ● ● ● ● ● 7 Pin SIL Low ripple and noise Isolation 6 kVDC 60 sec. 100% tested Rated for 250Vrms MTBF > 2.3 Mhours Operating temperature range -40...85°C Efficiency up to 82 % Model selection guide Typ P1C053R3S P1C0505S P1C0509S P1C0512S P1C0515S P1C123R3S P1C1205S P1C1209S P1C1212S P1C1215S P1C243R3S P1C2405S P1C2409S P1C2412S P1C2415S P1C0505D P1C0509D P1C0512D P1C0515D P1C1205D P1C1209D P1C1212D P1C1215D P1C2405D P1C2409D P1C2412D P1C2415D 1. 2. 3. 4. 5. 6. Input nominal voltage [VDC] 4.5..5.5 4.5..5.5 4.5..5.5 4.5..5.5 4.5..5.5 10.8..13.2 10.8..13.2 10.8..13.2 10.8..13.2 10.8..13.2 21.6..26.4 21.6..26.4 21.6..26.4 21.6..26.4 21.6..26.4 4.5..5.5 4.5..5.5 4.5..5.5 4.5..5.5 10.8..13.2 10.8..13.2 10.8..13.2 10.8..13.2 21.6..26.4 21.6..26.4 21.6..26.4 21.6..26.4 Output voltage Output current [VDC] 3.3 5.0 9.0 12.0 15.0 3.3 5.0 9.0 12.0 15.0 3.3 5.0 9.0 12.0 15.0 ±5.0 ±9.0 ±12.0 ±15.0 ±5.0 ±9.0 ±12.0 ±15.0 ±5.0 ±9.0 ±12.0 ±15.0 Efficiency typ. [mA] 303 200 111 84 67 303 200 111 84 67 303 200 111 84 67 ±100 ±56 ±42 ±34 ±100 ±56 ±42 ±34 ±100 ±56 ±42 ±34 [%] 69 70 70 70 70 71 74 74 74 74 75 77 80 80 80 70 70 72 70 73 74 75 75 78 80 81 81 Capacitve load [µF] 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 2 x 100 2 x 100 2 x 100 2 x 100 2 x 100 2 x 100 2 x 100 2 x 100 2 x 100 2 x 100 2 x 100 2 x 100 Ripple and Noise measured with 20MHz bandwidth Tested by minimal Vin and constant resistive load. Measured Input reflected ripple current with a simulated source inductance of 12µH. Exceeding the absolute ratings of the unit could cause damage. It is not allowed for continuous operating. Operation under no-load conditions will not damage these devices, however they may not meet all listed specifications. For reduce converter’s ripple and noise, it is recommended to add a 4.7..100μF(2 x 4.7..68μF for dual output) capacitor on output. For EMI performance improvement, it is recommended to add a 12μH inductor and a 10..100μF capacitor in input end. Page 1 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W DC-DC Converter P1C-Series Specifications Input Voltage range Filter I/O-Isolation: DC-Isolation voltage tested for 60 sec. Resistance Capacitance Output Voltage accuracy Voltage balance (dual outputs) Ripple and noise (at 20 MHz BW) Short circuit protection Line voltage regulation @ 1% Vin change Voltage stability at load change 20...100% EMC EME ESD RS ± 10% Capacitors 6 kV 9 10 Ω, max. 10 pF, typ. ± 3%, max. ± 1% 75 mVp-p, max. Momentary ± 1.2% ± 10% ± 20% @ 3.3V output EN 55022 Class B FCC47 CFR part 15 A IEC 61000-4-2 / B IEC 61000-4-3 / A General Safety standard Switching frequency Environmental Operating temperature (ambient) Case temperature Storage temperature Derating Humidity Cooling Physical Dimensions Weight Case material Capacitive Load: Single Output Dual Output Pin soldering temperature 1.5mm distance from body IEC 60950-2001 20…50 kHz -40 °C to +85 °C 100 °C, max. -40 °C to +125 °C None required Up to 95% rel. humidity, non-condensing Free-air convection SIL 19.5x9.8x12.5 mm 4.2 g non-conductive black plastic (UL94V-0 rated) 220 µF, max. 100 µF, max. 260°C for 10sec Dimensions Pin connections Pin 1 2 5 6 7 Single +V Input -V Input -V Output Omitted +V Output Dual +V Input -V Input -V Output Common +V Output Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 08.10 f Page 2 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]