Preview only show first 10 pages with watermark. For full document please download

2-ols-cm-led-2

   EMBED


Share

Transcript

OLS-CM-LED 4-13/16 4-13/16 LED ARCHITECTURAL SURFACE LINEAR DIRECT SYSTEM 4 3-7/8 4” 2-1/2 2-3/8 2” AVAILABLE IN CUSTOM GEOMETRIC SHAPES: INCLUDING TEES, CROSSES, AND CORNERS OF VARYING ANGLES. MINIMUM ORDER REQUIRED, PLEASE CONSULT FACTORY FOR DETAILS. CORNER 90º CROSS 90º TEE 90º (OTHER ANGLES AVAILABLE) 26 OLS-CM 27 OLS-CM-LED REFLECTORS - Fabricated of 20 gauge aluminum. Post painted finish with 95% reflective premium paint. LED ARCHITECTURAL CEILING MOUNT DIRECT LINEAR SYSTEM ENDCAPS - Die cast aluminum endcap. FABRICATION - Rigid design made with extruded aluminum ensures longevity and endurance. FINISH - White aluminum electrostatic paint DIFFUSER - Smooth white frosted acrylic lens for glare free light and even distribution. Precision cut, snap in design. 4” lens 3.858” width 2” lens 2.361” width. PERFORMANCE - The light engines found in the OLS-D are rated at 85+ CRI and are available in multiple CCTs: 3000K, 3500K, 4000K and 5000K. Rated and tested to LM-79 and LM-80 standards. The LEDs are also binned to a 3-step MacAdam ellipse to achieve consistent color from fixture to fixture. ELECTRICAL - Powered by high-quality constant-current power LED drivers which are rated for 50 to 60Hz at 120-277V input, produce less than 20% THD, and have a power factor of .90 to 1.00. Male and Female 18-gauge 6 wire plug connectors are included with every fixture to allow for simple hassle-free continuous wiring. Each fixture must be installed male to female. APPLICATION: Ambient lighting for glare-free, smooth illumination ideal for institutional, commercial and retail application. DIMMING - The OLS-CM comes standard with 0-10V dimming on either 120 or 277V. Dimmable down to 1% of initial lumens. Also available in Lutron dimming options. Consult factory for dimmer compatibility. PRODUCT FEATURES: • Available in 100% downlight configuration • Standard length 2’, 4’ and 8’ • Aperture width include 2” and 4” • Rigid aluminum extrusion made out of T6063-T5 aluminum, die cast aluminum end caps • Emergency battery back-up comes pre-installed on the fixture and emergency push button is installed on the fixture for easy access and aesthetics. • Optical system offers high efficiency LED light that passes through a smooth acrylic lens for optimal distribution patterns, thus creating a glare-free and even distribution for your application • Life tested to 50,000 hours of operation to L70 • Tested to LM-79 and LM-80 standards • Full ability to tandem mount for continuous run application complete with easy quick connects • Also available in recessed and wall mount STANDARD LENGTHS - All luminaires are supplied in nominal lengths to ensure even illumination. Runs and configurations are available in app. 2’, 4’ and 8’ increments. CRM INSTALLATION - For continuous row mounting, the first fixture in the row will always be the power supplies feed. After plugging in the male and female harnesses, which are supplied with each fixture, they will easily slid together, then secured with two screws from opposite direction in the connecting brackets. This allows for fixtures to be continuously connected with only removing the lenses. There is no need to remove any other parts in the fixture to install the continuous run. EMERGENCY - 10W emergency power lasts for 90 minutes. Max. mounting height is 15-1/2’ OPTIONS - Fixtures can be shipped pre-installed with daylight harvesting controls, occupancy sensors, and/or power pack. Available manufacturer options include Leviton, Wattstopper, Hubble Automation, and others. QUALITY CONTROL - Every fixture is rigorously tested by our QC Department before shipping. WARRANTY - Limited 5 Year Warranty Ordering Information: Example: 4-OLS-CM-LED-2-500L-DIM10-MVOLT-30K-85-CRM Single Run OLS-CM-LED SHAPE S - Single Unit CR - Continuous Run REC - Rectangle CUS - Custom (Consult Factory) SERIES WIDTH DIMMING VOLTAGE OLS-CMLED-Oracle Ceiling Mount LED Linear 2 - 2” 4 - 4” DIM10 - DIM10-MVOLT LUTH - LUTH-MVOLT MVOLT 347* LUMENS 500L / foot 750L / foot 1000L / foot 2’, 4’ OR 8' Cont. Run SMART WHITE SW - Smart White SMART HUE SH - Smart Hue DRAW YOUR CUSTOM SHAPE HERE TOTAL RUN Rectanle * Consult factory for details CCT 30K - (3000K) 35K - (3500K) 40K - (4000K) 50K - (5000K) W L WIDTH 28 LENGTH CRI EMERGENCY 85 O-EMG-LED FINISH WH - White SI - Silver CUSTOM - Consult COLOR factory OTHER OPTIONS INMS - Internal Motion Sensor FBF - Internal Fast Blow Fuse SBF - Internal Slow Blow Fuse RIS - Radio Interference Sensor WW - Wall Wash USA - Made in America Compliance ASI-DJ-CLIP - Drywall toggle A - Standard B - Cnt. End Feed C - Cnt. Middle D - Cnt. End Non-Feed A For continuous row mounting, the first fixture in the row will always be the power supplies feed. After plugging in the male and female harnesses, which are supplied with each fixture, they will easily slid together, then secured with two screws from opposite direction in the connecting brackets. This allows for fixtures to be continuously connected with only removing the lenses. There is no need to remove any other parts in the fixture to install the continuous run. B C D Cont. end feed fixtures come with electrical cord attached and wired EFFICACY: 105 LM/W 4-OLS-CM-LED-2-1000-DIM10-MVOLT WATTAGE: 37.8 W Candle Power Distribution (Candelas) 1556 1167 778 Connect male and female connectors from fixture to fixture LUMENS: 3988 TOTAL LUMINAIRE EFFICACY: 105 Zonal Lumens Summary Zone Lumens %Lamp %Fixt 1170.9 29.40 29.40 0-300 0-400 1878.99 47.10 47.10 0-600 3186.75 79.90 79.90 0-900 3987.55 100.00 100.00 0-1800 3987.55 100.00 100.00 Candela Tabulation Luminance Data (cd/sq.m) Angle In Average Degrees 00 450 550 650 750 850 Average 450 Average 900 11064 10700 10296 10153 9844 9403 9285 9004 8579 8627 8353 7964 8264 8343 7882 389 90° RC RW Spacing Criteria 0-180 : 1.24 90-270 : 1.20 Diagonal : 1.30 40° 30° 0° 10° 20° ROOM CAVITY RATIO 60° 50° 80% 70% 50% 30% 10% 70% 70% 50% 30% 10% 536 357 50% 30% 50% 30% 10% 50% 30% 10% LUMENS: 1854 Zonal Lumens Summary Zone Lumens %Lamp %Fixt 542.17 29.30 29.20 0-300 0-400 872.15 47.10 47.00 0-600 1480.91 79.90 79.90 0-900 1853.68 100.00 100.00 0-1800 1853.68 100.00 100.00 Candela Tabulation Luminance Data (cd/sq.m) Angle In Average Degrees 00 450 550 650 750 850 Average 450 Average 900 5073 4922 4769 4706 4528 4357 4302 4140 3981 3904 3793 3658 3884 3893 3750 Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF 80° 40° 30° 0° 10° 20° RC RW Spacing Criteria 0-180 : 1.22 90-270 : 1.20 Diagonal : 1.32 ROOM CAVITY RATIO 60° 0% 0% TOTAL LUMINAIRE EFFICACY: 104 90° 50° 10% 50% 30% 10% RW - Wall Reflectance 179 70° 90 1555.135 1551.990 1486.350 1321.270 1124.120 893.630 662.050 445.060 253.010 84.320 11.120 EFFICACY: 104 LM/W 4-OLS-CM-LED-2-500-DIM10-MVOLT WATTAGE: 17.9 W 715 45 1555.135 1549.800 1505.170 1344.650 1150.610 928.700 693.060 467.070 265.360 89.250 12.800 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 1 109 104 100 96 106 102 98 94 98 94 91 94 91 89 90 88 86 84 2 99 91 84 79 97 89 83 78 86 80 76 82 78 74 79 76 72 70 3 91 80 72 66 88 79 71 65 76 69 64 73 67 63 70 66 62 60 4 83 71 63 56 81 70 62 56 67 60 55 65 59 54 63 58 53 51 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44 6 71 58 49 42 69 57 48 42 55 47 42 53 47 41 52 46 41 39 7 66 52 44 38 64 52 43 37 50 43 37 49 42 37 47 41 37 35 8 61 48 39 34 60 47 39 34 46 39 33 45 38 33 43 37 33 31 9 57 44 36 30 56 43 36 30 42 35 30 41 35 30 40 34 30 28 10 54 41 33 28 53 40 33 28 39 32 27 38 32 27 37 31 27 25 RC - Ceiling Cavity Reflectance Candle Power Distribution (Candelas) 0 1555.135 1547.750 1500.540 1378.230 1189.960 960.310 714.790 481.680 274.080 88.410 10.670 Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF 80° 70° 0 5 15 25 35 45 55 65 75 85 90 80% 70% 50% 30% 10% 70% 70% 50% 30% 10% 0 5 15 25 35 45 55 65 75 85 90 0 714.916 710.590 680.380 622.540 540.400 440.290 331.310 223.190 124.030 41.550 3.760 45 714.916 711.400 679.590 618.250 530.850 427.240 318.780 214.750 120.500 41.650 5.930 50% 30% 50% 30% 10% 50% 30% 10% 90 714.916 712.090 679.180 612.750 520.060 413.920 306.780 206.530 116.220 40.120 5.820 10% 50% 30% 10% 0% 0% 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 1 109 104 100 96 106 102 98 94 98 94 91 94 91 89 90 88 86 84 2 99 91 84 79 97 89 83 78 86 80 76 82 78 74 79 76 72 70 3 91 80 72 66 88 79 71 65 76 69 64 73 67 63 70 66 62 60 4 83 71 63 56 81 70 62 55 67 60 55 65 59 54 63 58 53 51 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44 6 71 58 49 42 69 57 48 42 55 47 42 53 46 41 52 46 41 39 7 66 52 44 38 64 52 43 37 50 43 37 49 42 37 47 41 37 35 8 61 48 39 34 60 47 39 33 46 38 33 45 38 33 43 37 33 31 9 57 44 36 30 56 43 36 30 42 35 30 41 35 30 40 34 30 28 10 54 41 33 28 52 40 33 27 39 32 27 38 32 27 37 31 27 25 RC - Ceiling Cavity Reflectance RW - Wall Reflectance 29