Preview only show first 10 pages with watermark. For full document please download

2 -wire Intercom System - Intelligent Home Online

   EMBED


Share

Transcript

2 -Wire Intercom System DT598 User Manual DT-ENG-598-V1 100S804 CONTENTS 1.Parts and Functions...................................................................... 1 2.Terminal Descriptions................................................................... 1 3.Mounting and Setting.................................................................... 2 3.1 Door station Mounting .......................................................... 2 3.2 Placing Name Label................................................................ 3 3.3 Adjusting Camera Angle......................................................... 3 3.4 Button Mode Setting............................................................... 4 4.System Wiring and Connections................................................... 4 4.1 Basic Connection.................................................................... 4 4.2 Electric Lock Connection........................................................ 5 4.2.1 Door Lock Controlled with Internal Power........................ 5 4.2.2 Door Lock Controlled with Dry Contact............................. 5 4.2.3 How to setup the unlock parameter in Monitor.................. 6 4.3 Multi Door stations Connection............................................... 7 4.4 Multi Monitors Connection...................................................... 8 4.4.1 Basic IN-OUT Wiring Mode............................................. 8 4.4.2 With DBC-4 Wiring Mode................................................. 9 5.DIP Setting.................................................................................... 10 5.1 DIP Switches Settings of Doorstation..................................... 10 5.2 DIP Switches Settings of Monitor........................................... 10 5.3 Notices.................................................................................... 12 6.Specifications................................................................................ 12 7.Cables Requirements................................................................... 13 1.Parts and Functions Microphone LED Indicator 178mm 178mm Camera Lens Speaker Call Button A Call Button B 16.5mm 59mm 128mm 2.Terminal Descriptions ON SET DIP 1 2 3 4 5 6 Doorstation Code DIP PA Button MIC adjustment SPK adjustment PB Button BUS JP-LK T/RT/R+ EB+ EBN.O. LK+(COM) LK-(GND) +12V -1- RS485 3 2 1 CN-LK Lock Control Jumper Main Connection Port • • • • • • • • • • • • • +12V: 12VDC power output. LK-(GND): power ground. LK+(COM): electronical load activation ralay contact common. electronical load activation ralay normally open contact(refer to DT technical guide for Lock connection detail informations). EB+: Exit button. EB-: Exit buton. JP-LK: For electronic lock safety type setting(refer to Door Station Lock Connections). T/R-: USB-RS485 communication terminal negative. T/R+: USB-RS485 communication terninal positive. SET: DIP switches for system configurations. PA: program button A(refer to program section). PB: program button B.(refer to program section). Bus(L1,L2): non-polarised bus line. NO.: 3.Mounting and Setting 3.1 Door station Mounting 1 2 4 3 -2- 3.2 Placing Name Label Use a screwdriver to open the transparent name label cover, insert a name paper, then put the plastic cover back to the panel. 3.3 Adjusting Camera Angle use one hand to press the unit and another hand with a screwdriver to loosen the screw and then adjust the angle of the camera ,then fix the screw. -3- 3.4 Button Mode Setting You can set either single button mode or double button mode on door station . •• Single Button Mode:that means the door station only has one button,it can only call the monitor with it's code among 00~15.please refer to 5.2. •• Double Button Mode:that means the door station has two buttons,A button can call the adress 00~15 of the monitor,and B button can call the adress 16~31 of the monitor.please refer to 5.2. How to set the button mode 1. Single Button Setting:set the DIP swiches of Bit 3 on door station to 'on' state (refer to 5.1),single button mode is perform immediatelly,at this mode,you can press A button or B button or both A and B button to call the monitors wihich code is within 0~15. 2. Double Button Setting:.set the DIP swiches of Bit 3 on door station to 'off' state (refer to 5.1),double button mode is perform immediatelly,at this mode,you can press A button to call the monitor which code is within 0~15.Or press B button to call the monitors with its' code 16~31.Please note that activating A and B button at the same time is invalid. Note:single button mode (DIP3=on)is default in restore setting. 4.System Wiring and Connections 4.1 Basic Connection monitor DPS PS4 + - AC~ -4- 4.2 Electric Lock Connection 4.2.1 Door Lock Controlled with Internal Power Note: 1. Electronic lock of Power-on-to-unlock type should be used. 2. The door lock is limited to 12V, and holding current must be less than 250mA. 3. The door lock control is not timed from Exit Button(EB). L1 L2 JP-LK T/R - BUS Connect to DPS T/R+ Jumper position in 1-2 +12V LK - (GND) LK+(COM) N.O. EB EB+ 4. The Unlock Mode Parameter of Monitor must be set to 0 (by default). 1 2 3 RS-485 LOCK EB 4.2.2 Door Lock Controlled with Dry Contact Note: 1. The external power supply must be used according to the lock. 2. The inside relay contact is restricted to AC or DC 24V/3A. 3. The jumper must be taken off before connecting. 4. Setup the Unlock Mode of Monitor for different lock types. L1 L2 RS-485 POWER SUPPLY LOCK -5- JP-LK T/R - BUS Connect to DPS T/R+ Take off the Jumper +12V LK - (GND) LK+(COM) N.O. EB EB+ •• Power-on-to-unlock type:Unlock Mode=0 (by default) •• Power-off-to-unlock type:Unlock Mode=1 1 2 3 4.2.3 How to setup the unlock parameter in Monitor Outdoor Tone -- 01 monitor Intercom Tone -- 05 intercom Monitor Time -- 1min Password: 0 Advanced Set... setup Auto Record exit -- *** OFF Exit 1.Press MENU button twice 2.Select Advanced Set...item to enter the MAIN MENU and press MENU button to page,then press setup item. enter,a password will be asked. 3.The default password is 2008. press / button to change the value,Press / button to select the location,after finishing,press MENU button to enter next step. Unlock Time 1 Unlock Mode 0 Exit 6.Use / to select the item, use / to change the value of the item.select Exit Hardware ver 0302 Slave Addr Set -- 0 Software ver 0168 Guard Unit Set -- 0 Voltage 22.4V Date/Time Set... Manufacture 00.0T Other Settings... Restore to default Information... Exit Exit 5.Press UNLOCK button 4.Select Information...item and hold for 2s. and press MENU button to enter next page. item,press MENU button to save the settings automatically. Note: 1.must connect DT598 correctly before setting. 2.the parameter will be saved in DT598 automatically, so you need only set on one monitor. -6- 4.3 Multi Door stations Connection monitors DPS DBC4 BUS PS5 A B C D 85~260VAC 3# Camera 4# Camera L1 L2 2# Camera 1# Camera ID=10 ID=01 ID=11 ID=00 ON ON ON ON 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 L1 L2 L1 L2 -7- L1 L2 4.4 Multi Monitors Connection 4.4.1 Basic IN-OUT Wiring Mode ON monitor 1 2 3 4 5 6 Code=31, DIP-6=on ON monitor 1 2 3 4 5 6 Code=30, DIP-6=off ON monitor 1 2 3 4 5 6 Code=0, DIP-6=off PS5 DPS 85~260AC ID=00 ON 1 2 3 4 5 6 Note: 1. Monitors response user code from 0 to 15 for single button mode. 2. Monitors response user code from 0 to 31 for double button mode. -8- 4.4.2 With DBC-4 Wiring Mode ON ON 1 2 3 4 5 6 monitor 1 2 3 4 5 6 monitor HI OUT IN Code=30, DIP-6=on Code=31, DIP-6=on A B C D DBC-4 ON ON 1 2 3 4 5 6 1 2 3 4 5 6 monitor Code=29, DIP-6=on ON ON 1 2 3 4 5 6 monitor Code=28, DIP-6=on monitor 1 2 3 4 5 6 HI monitor OUT IN Code=2, DIP-6=on Code=3, DIP-6=on A B C D 1 2 3 4 5 6 Code=1, DIP-6=on monitor 1 2 3 4 5 6 monitor Code=0, DIP-6=on PS5 DPS 85~260AC Note: ID=00 1. Monitors response user code from 0 to 15 for single button mode. 1 2 3 4 5 6 ON 2. Monitors response user code from 0 to 31 for double button mode. -9- DBC-4 ON ON 5.DIP Setting ON(1) ON ON 1 2 3 4 5 6 = OFF(0) ON = 5.1 DIP Switches Settings of Doorstation Total 6 bits in the DIP switches can be configured. The switches can be modified either before or after installation, but restart the power supply is needed whenever the switches have been modified. • Bit-1 and Bit-2 is for door station ID settings, when mutil door stations are installed in the system, these two bit must be set correctly, the first door station set to 00, the second one set to 01, the third one set to 10, the fourth one set to 11. If only one door station is installed, set to 00. • Bit-3: Single button mode or double line button mode for door station selection. set 'on' state to be single button mode,set 'off' state to be double line button mode. • Bit-4:reserved and unused. • Bit-5: Unlocking time quick selection, by default it is set to 0, for 1 second unlocking time; set to 1 for 5 seconds. • Bit-6: reserved and unused. 5.2 DIP Switches Settings of Monitor There are 6 bit switches in total. The DIP switches are used to configure the User Code for each Monitor. Bit-6 is line terminal switch, which have to be set to ON if the Monitor is in the end of the line(bus), otherwise set to OFF. Bit state ON 1 2 3 4 5 6 Setting The monitor is not at the end of the bus. -10- Bit state ON 1 2 3 4 5 6 Setting The monitor is at the end of the bus. Bit-1 to Bit-5 are used to User Code setting. The value is from 0 to 31, which have 32 different codes . Bit state User Code Code=0 ON 1 2 3 4 5 6 Code=2 Code=3 Code=4 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 Code=9 Code=19 ON Code=10 1 2 3 4 5 6 Code=25 ON Code=26 ON Code=27 ON Code=28 ON Code=29 ON Code=30 1 2 3 4 5 6 Code=20 ON ON 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 ON Code=18 ON Code=24 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 ON Code=17 ON ON 1 2 3 4 5 6 1 2 3 4 5 6 Code=8 ON Code=16 ON Code=23 1 2 3 4 5 6 1 2 3 4 5 6 Code=7 ON Code=15 ON ON 1 2 3 4 5 6 1 2 3 4 5 6 Code=6 ON Code=14 ON Code=22 1 2 3 4 5 6 1 2 3 4 5 6 Code=5 ON Code=13 ON ON User Code 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 ON Code=12 ON Bit state 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 ON Code=11 ON 1 2 3 4 5 6 1 2 3 4 5 6 ON User Code 1 2 3 4 5 6 Code=1 ON Bit state ON Code=31 1 2 3 4 5 6 Code=21 ON 1 2 3 4 5 6 Note: 1. If the button mode is set to single button mode for door station,monitors response user code from 0 to 15. A B 2. If the button mode is set to double button for door station,monitors response button A must set the user code from 0 to 15.and button B set the user code from 16 to 31. -11- 5.3 Notices Name Discription Usage PS5-24V Power supply,85~260Vac input,24Vdc/3A Connect with multi doorstations or output,10 DIN modules multi monitors(up to 2 or above) PS4-24V Power supply,85~260Vac input,24Vdc/1A Connect with one doorstation and one output,for basic kit only,4 DIN modules monitor. 6.Specifications Lock Power supply: 12Vdc, 300mA(Internal Power) Power Consumtion: 1W in standby, 12W in working NO, COM dry contact: Max. 48V dc 1.5A Unlocking time: 1 to 9 seconds, set by Monitor Working temperature: -10ºC ~ 45ºC -12- 7.Cables Requirements The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach. The farest monitor monitor with two or four monitors monitor monitor DBC/DBC-4 B C When Monitor quantity < 20 DPS Cable Usage A B Twisted cable 2x0.75 mm2 60 60 30 Twisted cable 2x1 mm2 80 80 40 A When Monitor quantity > 20 Cable Usage A PS5 C B C Twisted cable 2x1 mm2 70 30 20 Twisted cable 2x1.5 mm2 70 50 30 Note:If the monitor has been specified the distance,refer to the parameter. -13- The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.