Preview only show first 10 pages with watermark. For full document please download

2 Wire Villa Home Techguide

   EMBED


Share

Transcript

CHALLENGER P R O 2 WIRE - Video Intercom System Technical Guide CONTENT Section1 - Introduction 1 System Features - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 Home Applications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 Apartment Applications- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3 System Function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-5 Section2 - Units and Installations 6 Door Station - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 Parts and functions - - - Place Name Plate - - - - Adjusting Camera Angle Electronic Specifications Door Station Mounting - Terminal Descriptions - - DIP user code settings - Door lock connection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -6 -7 -7 -7 -8 -9 -9 - 10-11 Monitor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -12 Features - - - - - - - - - - - - - - - Electronic Specifications - - - - Terminal Descriptions - - - - - - Intercom function - - - - - - - - - Color Picture Memory - - - - - SD Card - - - - - - - - - - - - - - - User Code Setup - - - - - - - - - Monitor Extending Connection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12 - 12 - 13 - 13 - 14 - 14 - 15 - 16 Accessories - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -17 PRO-PS5 - Power Supply PRO-DPS - - - - - - - - - - - PRO-DBC - - - - - - - - - - - PRO-DBC -4 Unit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17 - 18 - 19 - 20 This technical document is published for information purposes by PROVISION SECURITY PRODUCTS. In a policy of ongoing improvement, PROVISION SECURITY PRODUCTS reserves the right to modify the contents of this document and the features of the products referred to herein at any time and without prior notice. Any such modifications shall be reflected in subsequent editions of this document Section3 - Cables and Connections 24 General Rules for Installation - - - - - - - - - - - - - - - - - - - - - -24 Connecting the Connectors Installation Height - - - - - - - Door Station Install Condition Table of Cables and Distance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 24 - 24 - 24 - 25 System Wirings and Connections - - - - - - - - - - - - - - - - - - -26 1. Basic one to one wiring and Cable Length 2. Multi monitors IN -OUT wiring mode - - - 3. Multi monitors Star wiring mode - - - - - - - 4. Multi Door Stations star wiring mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Section4 -System Setup What’s User Code - - - - - - - - - - - - - - What's Slave Address - - - - - - - - - - - Installation setup on monitor - - - - - - - Shortcut for touch screen calibration of 1 - - 26 - 27 - 28 - 29 36 ------------------monitor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 36 - 36 - 37 - 39 Section1 - Introduction System Features • The Provision Challenger Pro 2 wire system can be easily installed in simple domestic home installations or complex apartment installations with up to 4 entrances. The best feature about Challenger Pro is that all products in the range are compatible and configurable to suit almost any installation requirement • Provision Challenger Pro offers a variety of door stations to suit the fussiest of customers. Choose from the super slim wall/desktop mounted 3.5” PRO16 through to the 10” PRO21 all with colorful interface and touch screen operation. Where required Picture memory option is available with PRO27, PRO692, PRO10, and PRO25 monitors • Choose from a variety of door stations ranging from a basic 1 button model up to code keypad or card reader with all in one design styles. Adjustable camera and IP67 full stainless steel construction are standard features across the Provision Challenger Pro door station range. Home Applications Supports up to 16 monitors and 4 door stations. 2 lock are also supported at each entrance 1 Apartment Applications Supports up to 32 monitors and 4 door stations. 1 lock is also supported at each entrance System Function Internal monitor station 1 ۞ Full range line 3.5’’/4’’/5’’/7’’/10’’ digital TFT; ۞ Super slim design with surface mounting; ۞ Touch screen operation with friendly interface; ۞ Intercom by name list and selective intercom; ۞ Selective monitoring each door stations or CCTV cameras; ۞ Inner 128M flash picture memory and extended SD card recording (SD card not supplied); ۞ Digital Photo Frame function; ۞ Wall & Desktop installation; ۞ 12 melody options; ۞ Mute function Door station ۞ Metal housing (Aluminium/Zinc –Alloy/ Stainless steel options-all IP66 weather rated); ۞ High resolution adjustable camera (CCD, ARS camera); ۞ Two independent relays for two locks control; ۞ Code lock control & Proximity access control ۞ Name plate display; ۞ Camera adjustable; ۞ Night -view; Additional features: ۞ Calling from door station; ۞ Dual communication with external unit; ۞ Dual intercom communication between indoor units; ۞ Unlock during calling, conversation, monitoring; ۞ Two locks for separate control; ۞ Picture capture and continuous photo shooting, Home -away function of auto -recording; Digital Photo Frame function (limited to PRO27, PRO692, PRO10, and PRO25 monitors supporting SD card); ۞ Multi languages choosing & SD card languages upgrading; PRO - System - Technical Guide 2 Section2 - Units and Installations Door Station Features • • • • • • • • • PRO591 Full zinc alloy panel. Pin -hole color CCD camera. Camera angle adjustable. Night -view LED. Backlight name plate. DIP switches for multi door station configuration. Direct connect to electronic lock of 12Vdc. Exit button. Plug -in connector to connect bus line. PRO592 Parts and functions Camera Lens Speaker 176 mm Night View LED Nameplate Call Button Microphone Rainy Cover 90 mm 4 23 mm Place Name Plate ON 1 2 Move the plastic cover away to open the transparent name label cover, insert a name paper, then put the plastic cover back to the panel. name label Adjusting Camera Angle Use a screwdriver to loosen the screw and then adjust the angle of the camera, then fix the screw. Electronic Specifications Power Supply : Power Consumption: Camera: Unlocking time: Talking Time: Lock Power supply: Working Temperature: Dimension: PRO - System - Technical Guide DC 24V (supplied by PROS4 -24V or PROS5-24V); Standby 50mA; Working status 200mA; Pinhole Sharp Color CCD; 420 TV Lines; 1 -9S, set by monitor; 90S; 12Vdc, 300mA(Internal Power); -100C~+450C; 176(H)×90(W)×24(D)mm 5 Door Station Mounting Mounting Without Rainy Cover 1 2 3 4 3 4 1 2 160-165cm Mounting With Rainy Cover 1 2 1 2 160-165cm 6 Terminal Descriptions 1 2 3 1 2 Doorstation Code DIP 1 2 ON ON Lock Control Jumper MIC adjustment SPK adjustment Main Connect Port • Lock Control Jumper: To select the lock type: see door lock connection section • Door station Code DIP: Total 4 door stations can be supported DIP SWITCHES IN OFF POSITION ON SINGLE DOOR SYSTEM • • • • • Main Connect Port: To connect the bus line and the electronic locks. BUS: Connect to the bus line, no polarity. PL: External lock power input, connect to the power positive(power +) S1+, S2+: Lock power(+) output, to connect 2 locks. S -: Lock power( -) output, connect to the power( -) input of locks(only when using the camera to power the locks, if using the external power supply for the locks, the S - will not be connected). DIP user code settings – ONLY APPLICABLE FOR MULTI DOOR STATION Total 2 bits on the DIP switches can be configured. The switches can be modified either before or after installation. Bit state ON Descriptions Default setting, ID = 0(00), set to the first Door Station. 1 2 ON ID = 1(10), set to the second Door Station. 1 2 ON ID = 2(01), set to the third Door Station. 1 2 ON ID = 3(11), set to the fourth Door Station. 1 2 PRO - System - Technical Guide 7 Door lock connection Door Lock Controlled with Internal Power Note: 1. Electronic lock of Power -on -to -unlock type should be used. 2. The door lock is limited to 12V, and holding current must be less than 250mA. 3. The door lock control is not timed from Exit Button(EB). 4. The Unlock Mode Parameter of Monitor must be set to 0 (by default). Connect one lock Connect two locks Connect one lock Connect two locks Jumper position in 1-2 BUS PL S1 + S2 + Jumper position in 1-2 BUS S- *EB PL S1+ S2+ S- 2nd * EB 2 nd LOCK LOCK *EB 1ST 1 ST LOCK Door Lock Controlled with Dry Contact Note: 1. The external power supply must be used according to the lock. 2. The jumper must be taken off before connecting. 3. Setup the Unlock Mode of Monitor for different lock types. • Power -on -to -unlock type:Unlock Mode=0 (by default) • Power -off -to -unlock type:Unlock Mode=1 8 Connect one lock Connect two locks Take off the Jumper BUS PL S1 + S2 + Take off the Jumper S- BUS PL S1 + S2 + S- POWER SUPPLY POWER SUPPLY LOCK LOCK Unlock parameter setting(set on monitor) Manual Monitor Memory Playback Monitor Album ? About 1.Touch menu page. Intercom H/W : S/W: Local addr: Unlock timing: Video standard: UI-CODE: MCM-VER.: Updated: Multimedia User Setup Close 09/30/2010 Thu.16:41 item on main --- a1.3 V17.11.418.00 ----------- 2.Touch the screen anywhere and hold for 2s. Installation settings: [0010]#:Remove all remote control [0011]#:Add remote control [8000]#:Set as master unit 0 [8001]#:Set as slaver unit 1 [8002]#:Set as slaver unit 2 [8003]#:Set as slaver unit 3 [8004]#:Set as guard unit [8005]#:Set as not guard unit [8006]#:Panel on as slaver unit called [8007]#:Panel off as slaver unit called [8008]#:Date format:MM/DD/YYYY [8009]#:Date format:DD/MM/YYYY [8010]#:Set lock mode to 0 [8011]#:Set lock mode to 1 [8021]~[8029] #Set the lock time of 1~9s Code Number:[----] 1 4 2 5 3 6 7 8 9 Installer setup Caliber TouchScreen 0 Multi language settings: --- Cancel 4.A digital keypad and setting instructions will be shown. Home 3.Touch Installer setup item Note: 1. Must connect PRO591/592 correctly before setting. 2. The parameter will be saved in PRO591/592 automatically ,so you need only set on one moni tor. PRO - System - Technical Guide 9 Monitor Features Screen Indicator Microphone Manual Monitor Memory Playback Monitor Intercom Album User Setup ? About Multimedia Close 09/30/2010 Thu.16:41 UNLOCK Button TALK/MON Button MENU Button Mounting Hook Speaker BT 1 BT 2 EH GN D VD DIP S L1 Connection Port ON L2 1 2 3 4 5 6 Mounting Hook SD card slot • Touch screen operation. • Picture memory optional. • Using DIP for Monitor ID setting. • Using plug -in connector. • On screen name list for intercom. • No additional power supply needed(supplied by system). • Additional door bell call button • External ringer connection *NB- red /black wire = ringer White/green wire = doorbell Black/ yellow wire = TV out Electronic Specifications Power supply: Power Consumption: Monitor Screen: Display Resolution: Dimension: 10 24Vdc(supplied by PRODPS) Standby 15mA; Working status 400mA 7 Inch color TFT -LCD 800*3(RGB)*480 pixels 125(H)×225(W)×23(D)mm Terminal Descriptions Monitor Connection Board BT1 BT2 EH GND VD • SW+: Door bell call button. • SW-: Door bell call button. • • • EXT-RING: External ringer output(12Vdc 100mA) DIPS L1 ON L2 1 2 3 45 6 . GND: Ground. VIDEO: Video signal output. • • S1: DIP switches for system configurations BUS: non polarity bus line . Intercom function There are three kinds of intercom function available in the Challenger PRO system. 1. Guard Unit Call A Monitor can be assigned to be the guard unit Monitor, by setting on the OSD screen of the Monitor. When the user's Monitor is in standby, press call button or intercom button, the intercom page will show up on the screen, then select and confirm 'Call Guard Unit' item, and the Monitor will call the guard unit Monitor, when the guard unit Monitor answers the call, conversation with the guard person is started. Please refer to section 4 ->system setup ->installation setup ->how to set the monitor as a guard unit. 2. Inner Call For multi monitor installs Intercommunication between monitors can be achieved via:  Press MENU  INTERCOM ICON OR INNER CALL (BY NAME LIST) When using name list function, select address and press ‘DIAL NUMBER ICON’ When the Monitor is in standby, press call button or intercom button, the intercom page will show up on the screen, than select and confirm 'Inner Call' item, and other Monitors will ring at the same time. When any Monitor answers the call, other Monitors will stop ringing and go back to standby state. 3. Intercom Call (Namelist) The name list intercom is for room to room calling. The user in one room can call other rooms by selecting the name on the screen. In this way, it's no need to remember the user code of the other users. PRO - System - Technical Guide 11 Color Picture Memory The monitors have been equipped with a built -in memory (about 120 MB) together with a SD card reader. An SD card up to 16 GB (Maximum) is supported . User can both record the pictures manually and set the Monitor to automatically record pictures. • • • • • Manually record: when the Monitor is in monitoring or talking state (the screen is turned on), press the capture icon on the touch screen, the captured pictures will be saved in a folder named by date and will be saved into the built -in flash memory of the Monitor. Automatically record: pictures will be saved after 3 seconds when the visitor pressed the call button on the Door Station. The captured pictures in the built -in memory can be copied to the SD card, and you should use T -views memo software tool to convert the pictures to JPG format that can be seen on the computer. (select the pictures(press Ctrl+A to select all) ->>click the right key of the mouse ->>choose transfer selected to JPG item ->>save the pic tures on computer) When the built -in memory is full,the oldest picture will be deleted to make room for new record . The built -in memory can be formatted by the Monitor. SD Card Built -in SD card reader, maximum 16 GB supported. • • • • • • Photo frame function, each photo playing will last 5 seconds, More pictures in the SD card, longer time for trig gering the function, 800 pictures is supported in inner memory. With 2G SD card more than 30000 pictures can be supported. Must use T -views album software tool to transform the JPG format photos taken by digital camera to TVS format photos that can be viewed on Monitor. Photos can be played both manually and automatically, use your fingers to slide right or left on screen to play last/next photo. The SD card cannot be formatted on monitor directly ,you should format the SD card on a computer. Avoid plugging in/out the SD card when the monitor is under operation. Playing will be interrupted by the calling from outdoor station. 12 PROGRAMMING How to enter the installation setting page Installation settings: Manual Monitor Monitor Memory Album Playback ? About Intercom User Setup Multimedia Close 09/30/2010 Thu.16:41 1.Touch item on main menu page. H/W : S/W: Local addr: Unlock timing: Video standard: UI-CODE: MCM-VER.: Updated: -- a1.3 ------------- 2.Touch the screen any where and hold for 2s. PRO - System - Technical Guide [0010]#:Remove all remote control [0011]#:Add remote control Installer setup Caliber TouchScreen [8000]#:Set as master unit 0 [8001]#:Set as slaver unit 1 [8002]#:Set as slaver unit 2 [8003]#:Set as slaver unit 3 [8004]#:Set as guard unit [8005]#:Set as not guard unit [8006]#:Panel on as slaver unit called [8007]#:Panel off as slaver unit called [8008]#:Date format:MM/DD/YYYY [8009]#:Date format:DD/MM/YYYY [8010]#:Set lock mode to 0 [8011]#:Set lock mode to 1 [8021]~[8029] #Set the lock time of 1~9s Home 3.Touch Installer setup item Multi language settings: --- Code Number:[----] 1 2 3 4 5 6 7 8 9 0 Cancel 4.A digital keypad and in structions will be showed. 13 How to set the slave monitor address Maximum 4 monitors can be connected in one apartment, one master monitor together with 3 slave monitors, so you should set the address correctly.(note :must have one monitor to be set as master monitor) The code of 8000 # is used to set the master monitor. The code of 8001 # is used to set the first slave monitor . The code of 8002# is used to set the second slave monitor . The code of 8003# is used to set the third slave monitor . Entry of ALL digits is required, for example 8008 is entered as 8 0 0 8 # Note :touch # to save the settings (MARKED AS ENTER IN DIAGRAM) and * button to cancel the input, touch (MARKED AS BACK SPACE IN DIAGRAM) How to set date and time format The system offers two methods of date and time 8009# is used to set the date format as date/month/year. 8008# is used to set the date format as month/date/year. 8012# is used to set the time format as 12 hour system 8013# is used to set the time format as 24 hour system How to set the monitor panel on 8006# is used to set the slave monitor as simultaneous display . This is required to be entered into EACH SLAVE monitor for simultaneous answer. In default mode, when receiving a call, the master and slave monitors will ring at the same time, and just the master monitor can display the image while the slave monitors cannot. The settings can be changed, you can set the master monitor and all the slave monitors to panel on at the same time when receiving a call, just input the code number of 8006 on each slave monitor. Press call button on door station 14 When receiving calling, all monitors can display the image at the same time How to set the unlock parameter UNLOCK MODE:: 8010# is used to set the unlock mode to 0 (POWER TO UNLOCK FAIL SECURE) 8011# is used to set the unlock mode to 1 (POWER TO LOCK FAIL SAFE) UNLOCK TIME: 8021# 1 SECOND ACTIVATION 2 SECOND ACTIVATION 8022# 3 SECOND ACTIVATION 8023# 4 SECOND ACTIVATION 8024# 5 SECOND ACTIVATION 8025# 6 SECOND ACTIVATION 8026# 7 SECOND ACTIVATION 8027# 8 SECOND ACTIVATION 8028# 9 SECOND ACTIVATION 8029# The unlock time can be set from 1 to 9 seconds. The code number from 8021 to 8029 are used to set the unlock time to 1~ 9 seconds as indicated above. How to set the menu language (for SD model only) The monitor can support multi languages and it is so simple and fast, just input the corresponding language code on monitor. The language code number are as follows: 8101: English 8102: French 8103: Spanish 8104: Italian 8105: German 8106: Dutch 8107: Portuguese 8108: S-Chinese 8109: T-Chinese 8110: Greek 8111: Turkish 8112: Polish PRO - System - Technical Guide 8113: Russian 8114: Slovakia 8115: Hungray 8116: Czech 8117:Hebrew 8118:Danish 8119:Romanian 8120:Slovenia 8121:Croatian 15 Shortcut for touch screen calibration of monitor OK! 1 1 2 2 2 2 3 1 3 3 3 4 4 4 4 In standby mode,touch the unlock button and hold for 2s. 16 1 “+” icon will be shown on screen,then touch “+” icon until the icon move to next location. The same as last operation. The same as last operation. When the screen display “ok”, that means the screen calibration is finished. THIS IS ONLY REQUIRED FOR MULTI DOOR STATION SYSTEMS ONLY User Code Setup – Room stations There are 6 bit switches in total. The DIP switches are used to configure the User Code for each Monitor. Bit -6 is used to set video impedance, it should be set to ON if the Monitor is in the end of the line(bus), otherwise set to OFF. ON(1) OFF(0) = = Bit state Setting Bit state The monitor is The monitor is ON not at the end of ON 1 2 3 4 5 6 1 2 3 4 5 6 the bus. -1 to Bit -5 are used to User Code setting. The value is from 0 to 31, which have 32 different codes . Bit state ON User Code Code=0 1 2 3 4 5 6 ON Code=2 Code=4 Code=5 Code=7 Code=8 1 2 3 4 5 6 ON Code=9 1 2 3 4 5 6 ON ON ON 1 2 3 4 5 6 1 2 3 4 5 6 ON ON 1 2 3 4 5 6 Code=6 1 2 3 4 5 6 ON ON Code=10 1 2 3 4 5 6 PRO - System - Technical Guide ON ON 1 2 3 4 5 6 Code=14 ON 1 2 3 4 5 6 Code=15 ON 1 2 3 4 5 6 Code=16 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 1 2 3 4 5 6 ON ON 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 User Code ON ON ON the bus. 1 2 3 4 5 6 Code=13 1 2 3 4 5 6 1 2 3 4 5 6 ON ON Bit state at the end of 1 2 3 4 5 6 Code=12 1 2 3 4 5 6 1 2 3 4 5 6 ON ON 1 2 3 4 5 6 Code=3 1 2 3 4 5 6 ON Code=11 1 2 3 4 5 6 1 2 3 4 5 6 ON ON User Code 1 2 3 4 5 6 Code=1 1 2 3 4 5 6 ON Bit state Setting ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 17 DIP user code settings for door station – Total 2 bits on the DIP switches can be configured. The switches can be modified either before or after installation. Bit state Descriptions Default setting, ID = 0(00), set to the first Door Station. ON 1 2 ID = 1(10), set to the second Door Station. ON 1 2 ID = 2(01), set to the third Door Station. ON 1 2 ID = 3(11), set to the fourth Door Station. ON 1 2 Monitor Extending Connection Manual Monitor Memory Playback Monitor Intercom Album User Setup ? About Multimedia Close 09/30/2010 Thu.16:41 BT1 BT2 EH GND VD DIPS L1 ON L2 1 2 3 4 5 6 B T1 B T2 EH GN D VD D IP S L1 ON L2 1 2 3 4 5 6 1. Door Bell Call Button Additional doorbell call button can be connected to the Mon itor, so that the visitors can ring the doorbell again in front of the user's apartment. When the call button is pressed, the Monitor will output ring tones but the screen will keep off, and the external ringer will ring at the same time (if a external ringer is installed). 18 Door bell call button SW+ SWEXT-RING GND VIDEO 2. External Ringer External ringer can be connected to the Monitor. The ringer will ring whenever the Door Station call button or the door bell call button is pressed, and it will stop ringing when the Monitor rejected or answered the call. External Ringer = = - + 12Vdc 300mA 3. TV -out function Connect television to the Monitor, when the Door Station calls, the user switch the channel to the AV channel, and the visitor's video will show up on the screen of the television. The core of the video cable must connect to the VD terminal, and the shielded layer connect to the GND. Television video cable PRO - System - Technical Guide SW+ SWEXT-RING GND VIDEO SW+ SWEXT-RING GND VIDEO 19 Accessories 352 PS5 - Power Supply The PRO-PS5 power supply unit is designed for PRO system to supply up to 32 Monitors and total 4 Door Stations at the same time. • • • • • • Universal AC input/full range. Multi protection: short circuit, overload, over voltage Cooling by free air convection DIN rail mounting. Support up to 32 Monitors Support up to 4 Door Stations. Dimension and Terminal 152.5 • • L (AC) N (AC) 65 • : Earth Ground. 97 V- L(AC): AC input. N(AC): AC input. VV+ V+ VADJ LED 24 • • V-: DC power output.(21.5~26.5 adjustable) • • VADJ: Output voltage adjustment. V+: DC power output.(21.5~26.5 adjustable) 78 159 150 22 117 LED: Working state indicator. 38 18 9 9 6.5 Unit: mm Electronic Specifications Input Voltage: Input Frequency: Rated Output Voltage: 50~60 Hz 24Vdc Rated Output Current: 4.5A Working Temperature: -200C~+600C Dimension: 20 100~120VAC(2.5A), 200~240VAC(1.5A) 159(H)×97(W)×37(D)mm DIN Installation PROS5 352DPS DIN nail 85~260AC PRODPS DPS: This unit is a power separator for the PROS5 or PROS4 power supply, it transfers the power from the power supply to the suitable power for the non -polarity bus. Note that the PRODPS must work together with the PROS5 or PROS4 power supply. PRODPS Connect to Door Station Connect to Power Supply(PROS5-24V) Connect to Monitor Technical Specifications(PRODPS) Power input: Power output: Power Consumption: Working temperature: Dimension: PRO - System - Technical Guide 24Vdc (supplied by PROS5) 18Vdc 0.25W in standby, 0.5 W in working -10ºC ~ +40ºC 89(H)×70(W)×45(D)mm 21 PRODBC PRODBC: This unit is a 2 wire branch controller unit used to transfer all data between the Monitor and the Bus Line. Every Monitor(except the last one at the end of the line) needs one DBC to connect to the Non -polarity Bus Line. No extra power supply needed, and one LED indicator to show the working state. PRODBC Bus In/Out Bus Out(to Monitor) Technical Specifications(PRODBC) Power Consumption: Working temperature: Dimension: -10ºC +40ºC 89(H)×70(W)×45(D)mm 45 mm PRODBC Dimensions 22 0.25W in standby, 0.5 W in working Direct Wall Mounting DIN Rail Mounting Use the screws to fasten the unit on the wall directly. Install on the DIN Rail. 85mm PRODBC 4S Unit PRODBC-4 Distributor is a 2 wire branch controller with 4 outputs distributor for the Challenger Pro system, to approach the star topology connection in the apartment system. See Section 3 Cables and Connection for detail connection information. set to 120 for the last DBC-4 on the building, the others must be set to HI. HI PRODBC4S Video Match 120 In-use Power Trunk Bus Bus Out PRO - System - Technical Guide Bus In D C B A Connect to Monitors 23 Technical Specifications(PRODBC4S) Power Supply : 0 0 -10 C~+40 C; Wiring: 88(H)×140(W)×32(D)mm PRODBC4S Dimensions 24 DC24V Temperature: 2 wires (non -polarity); Dimension: 140mm 13mm upward 62mm 88mm 70mm 84mm 32mm D C B A 36mm Trunk Bus HI 120 A/B/C/D port: Connect to Monitors/Door Station Trunk Bus: Bus input/output. Direct Wall Mounting PRO - System - Technical Guide DIN Rail Mounting 25 Section3 - Cables and Connections General Rules for Installation Connecting the Connectors Before screw the wire to the plug -in connector, it's important to process the wire in the correct way. See the following steps to connect the wire. 1. Strip the wire 2. Twist and bend it ~12mm 7~8mm 3. Put only the insulation-free part in the terminal Installation Height The recommended installation height of both Door Sta tion and Monitor is from 160~165 cm. 1 2 3 4 160~165 cm Door Station Install Condition The Door Station cannot be installed in a place that hard/large light sources can cover the lens of the camera(for example, the street light or Sun light), otherwise the video image will have lower contrast. If there is no way to avoid this condition, the alternative is to install the Door Station in a higher position and then adjust the camera angle towards down to keep the lens away from the light source. 26 Table of Cables and Distance The maximum distance of the wiring is limited in the Challenger Pro system. Using different cables may also effect the maxi - mum distance the system can reach. The farest monitor 1 2 3 4 1 DBC 1 2 2 3 3 4 4 B C When Monitor quantity < 20 DPS Cable Usage A B C Twisted cable 2x0.75 mm2 60 60 30 Twisted cable 2x1 mm2 80 80 40 PS5 A When Monitor quantity > 20 Cable Usage A B C Twisted cable 2x1 mm2 70 30 20 Twisted cable 2x1.5 mm2 70 50 30  The wire for the Non -polarity bus MUST non -shielded! And using the twisted wire is recommended, if using the Non -twisted wire, the total distance will be half. PRO - System - Technical Guide 27 System Wirings and Connections ON 1 2 1. Basic one to one wiring and Cable Length 1 2 3 4 PRODPS PROS4 L1 L2 PL S1+ S2+ S- - + NP NP AC~ NP:Non-polarized A B Cable A(m) B(m) ≤2 PRO27 B(m) ≤16 PRO27 CAT5 Cable (Combined) 40 80 ---- Pair Cable (Parallel) 2X0.75 mm2 30 50 ---- Twisted Cable 2X0.75 mm2 60 100 40 Twisted Cable 2X1.0 mm2 80 120 60 Here is a table for description of the two power supplies Item Input AC 100 -240V Output DC 24V 1A PROPS4-24V AC 100 -120V 2.5A & DC 24V 4.5A Voltage ad AC 200 -240V 1.5A ,AC justable: 21 to 27V, default PROS5-24V input voltage can be is 24V selected by switch. 28 Application Just can power the system with one door station and one monitor(PRO16 can be connected two). Can use it in all situation 2. Multi monitors IN -OUT wiring mode ON 1 2 3 4 5 6 1 2 3 4 Code=15, DIP-6=on ON 1 2 3 4 5 6 1 2 3 Code=14, DIP-6=off 4 ON 1 2 3 4 5 6 1 2 3 4 Code=0, DIP-6=off PS5 DPS 85~260AC ID=00 ON 1 2 PRO - System - Technical Guide 29 3. Multi monitors Star wiring mode ON ON HI 1 2 3 4 5 6 1 1 2 3 4 5 6 1 2 2 3 4 Code=14, DIP-6=on = OUT IN Code=15, DIP-6=on 3 4 A B C D DBC-4 ON ON 1 2 3 4 5 6 1 2 3 4 5 6 1 1 2 2 3 3 Code=12, DIP-6=on 4 Code=13, DIP-6=on 4 ON ON 1 2 3 4 5 6 = 1 1 2 3 4 5 6 2 1 2 3 3 4 4 Code=3, DIP-6=on OUT IN Code=2, DIP-6=on A B C D 1 2 3 4 5 6 1 2 1 2 3 4 5 6 3 4 Code=1, DIP-6=on 1 2 3 Code=0, DIP-6=on 4 DPS PS5 85~260AC ID=00 ON 1 2 30 DBC-4 ON ON Section4 -System Setup • Pick -up waiting time: this is the duration from when a call is made from a Door Station to when the called monitor is picked up; the system will cut off the call after this period of time.(the default setting is 30 seconds) • Maximum talking time: this is the duration time that the indoor user can talk to the out door visitor. After this period the conversation will be cut off automatically by the system to free the line.(the default setting is 90 seconds) • Maximum intercom time: this is the duration time that the indoor user can talk to the other indoor user when having an intercom conversation. After this period the conversation will be cut off automatically by the system to free the line.(the default setting is 30 seconds) • Maximum monitoring time: this is the duration time that the indoor user can monitor (surveillance) via the Door Station, when press the Monitor button on the Monitor.(the default setting is 30 seconds) • Busy time: this indicates the period when a door unit can not place calls because a previous call or conversation is in progress.(maximum busy time = pick -up waiting time + maximum talking time) What’s User Code In 2 -wire CHALLENGER PRO system, each Monitor installed in system must be programmed with a calling address or calling number, which is User Code. For Monitor, User Code is defined by 1~5 bits DIP switches on the connection board, according the User Code rules. For example, if you want to program the Monitor’s User Code to be “03”, the Monitor’s 1~5 bit DIP switches should be set as: ON, ON, OFF, OFF, OFF(please refer to User Code table at section2 -Monitor). For Door Station, the Call Button on panel is assigned to a specified User Code, and press this button will call re lated Monitor. For example ,for PRO592, press the below call button , system will launch a call to the Monitor which programmed with “00~15” User Code. Press the above call button system will launch a call to the monitor which pro grammed with "16~32" user code. What's Slave Address 2 –wire CHALLENGER-PRO system is capable of connecting up to 4 Monitors in one apartment, which means they will have the same U•ser Code, and will be called simultaneously. In this condition, the Monitors should be programmed as below: All the Monitors of same apartment must be programmed with the same User Code on the DIP switches. • There is only one master Monitor in the one apartment, and the Slave Address of the master Monitor is set to 0. Each Slave Monitor should be set from 1~3. • By default, Monitor’s Slave Address is preset to 0(master Monitor). • By default ,when Door Station calls, only the master Monitor will turn on the screen, the slave Monitor will only ring. PRO - System - Technical Guide 31 Master Monitor Slave Monitor 1 Slave Monitor 2 Slave Monitor 3 Slave Address 0 Slave Address 1 Slave Address 2 Slave Address 3 Please note, when called by Door Station, all Monitors will ring, however, only the Monitor which Sub User Code was programmed to 0 will turn on the screen by default. Programming Slave User Code is by means of Monitor Menu, for more detailed operation, please refer to the followings as below: Installation setup on monitor How to set the monitor as a Guard Monitor A Monitor can be assigned as Guard Unit Monitor; when the Guard Unit Monitor answers the call, conversation with the guard person is started.. The code number of 8004 is used to set the monitor as a guard unit monitor and 8005 is used to cancel this function. 32 CHALLENGER PRO User Code Programming Table page1/2 User code Bit state Room Name Label Remark ON 00 1 2 3 4 5 6 ON 01 1 2 3 4 5 6 ON 02 1 2 3 4 5 6 ON 03 1 2 3 4 5 6 ON 04 1 2 3 4 5 6 ON 05 1 2 3 4 5 6 ON 06 1 2 3 4 5 6 ON 07 1 2 3 4 5 6 ON 08 1 2 3 4 5 6 ON 09 1 2 3 4 5 6 ON 10 1 2 3 4 5 6 ON 11 1 2 3 4 5 6 ON 12 1 2 3 4 5 6 ON 13 1 2 3 4 5 6 ON 14 1 2 3 4 5 6 ON 15 1 2 3 4 5 6 PRO - System - Technical Guide 33 CHALLENGER PRO User Code Programming Table page1/2 User code Bit state ON 16 1 2 3 4 5 6 ON 17 1 2 3 4 5 6 ON 18 1 2 3 4 5 6 ON 19 1 2 3 4 5 6 ON 20 1 2 3 4 5 6 ON 21 1 2 3 4 5 6 ON 22 1 2 3 4 5 6 ON 23 1 2 3 4 5 6 ON 24 1 2 3 4 5 6 ON 25 1 2 3 4 5 6 ON 26 1 2 3 4 5 6 ON 27 1 2 3 4 5 6 ON 28 1 2 3 4 5 6 ON 29 1 2 3 4 5 6 ON 30 1 2 3 4 5 6 ON 31 1 2 3 4 5 6 34 Room Name Label Remark Provision Security Products Pty Ltd www.provisioncctv.com.au PRO System Technical Guide_V1.0 PRO - System - Technical Guide 35 3 4. Basic Door Release Operation 1. Press CALL button on outdoor station, the Monitor rings, at the same time, the screen displays the visitors' image. DS-1 00:23 2. Press TALK/MON Button on monitor or touch icon on screen, you can communicate hands free with the visitor for 90 seconds.After finishing communication,press TALK/MON button again or touch icon to end the communication. If nobody answers the phone, the screen will be turned off automatically after 30 seconds. 3. During talking state, Press UNLOCK Button or touch corresponding door for the visitor. or icon to open the 4. When the monitor is in standby mode, press TALK/MON Button(or touch Monitor ... item on main menu page), The screen can display the view of outside. If multi door stations are installed, touch icon to get into the camera switch mode(or direct touch Manual Monitor item on main menu page). You can touch camera 1/2/3/4 to monitor the door station or CCTV camera you want.See the following diagrams.(Press TALK/MON button again touch icon to end monitoring.) DS-1 00:23 Monitor Select Camera 1 ... Camera 2 ... Camera 3 ... Camera 4 ... Monitor Time Set ... Exit Home 5. Intercom Function Intercom Touch Intercom item on main menu page,there are three items:Intercom Call...,Inner Call ...,Direct Call Guard Unit... Intercom Call ... Inner Call ... Direct Call Guard Unit ... Exit Home 4 1. Intercom Call: User in one apartment can call other apartments in the system. the namelist will be created automatically by the system. Touch a name you want on the screen, then touch icon to dial.(Note:1. touch icon again to redial. 2.The DIP switches code of each monitor must set different.) Intercom Call [ 00 ] [ 01 ] [ 02 ] [ 03 ] [ 04 ] [ 05 ] Jim. Zhang Calo. Liu Jacko. Zhang Philips. Chen Hebe. Zhang Tony. Li Exit Calling Next Page 2. Inner Call: If multi slave monitors are installed in the same apartment, select Inner Call, all the other Monitors will ring at the same time, whichever Monitor answers the call, conversation is started.and the other monitors will stop ringing at the same time.(note:the DIP switches setting of all monitors must be same. ) 3. Direct Dial Guard unit: A Monitor can be assigned as Guard Unit Monitor; when the Guard Unit Monitor answers the call, conversation with the guard person is started.. 6. Basic Setup Instructions Ring Tone Settings Touch User Setup item on main menu page to enter setup page.Touch Door Station Call Tone, Inercom Call Tone or DoorBell Tone item, There are 12 pieces ring tones can be selected.touch a ring tone you want, then touch icon to save and exit.(touch icon to cancel the setting and return last page, touch icon to get into main menu page) Door Station Call Tone :set the ring tone calling from outdoor station. Intercom Tone :set the ring tone calling from other apartments. DoorBell tone :set the ring tone calling from door bell. User Setup (1) Door Station Call Tone ... Intercom Call Tone ... DoorBell Tone ... Clock ... Next Page Exit Home Door Station Call Tone Selected: 1 Carmen 2 Ding Dong 3 Rain 4 For Alice Cancel 06 5 Sonatine 9 Do Re Me 6 Edelweiss 10 Happy Birthday 7 Going Home 11 Jingle Bells 8 Congratulation 12 Telephone Ring Home Save&Exit 5 Ring Volume and Night Ring Volume Setting You can set a ring volume for day time and night time individually, 6:00 AM~18:00 PM is the day time and 18:00 PM~6:00 AM is the night time by default,if you don't want to be disturbed at night,you can set the night ring volume to 0. Touch User Setup item on main menu page to enter setup page,then touch Next Page item to enter User Setup 2 page, select Ring Volume Setting or Night Ring Volume item. then touch ▲ / ▼ icon to increase / decrease the value; After finish, touch icon to save and exit.(touch icon to cancel the setting and return last page, touch icon to get into main menu page) User Setup (2) Ring Volume ... Night Ring Volume ... TPC Configure ... Restore to default ... Last Page Exit Home Ring Volume Current : Cancel 05 Home Save&Exit 7. Date and Time Setting Touch User Setup item on main menu page to enter setup page, touch Clock... item. a digital keypad will be showed on screen, input date and time by touching the digital keypad,use * key to select the setting item. After finish, touch icon to save and exit.(touch icon to cancel the setting and return last page.) Clock 2010 - 12 - 28 1 2 4 5 7 8 0 * Cancel 15 : 00 3 6 9 # Save&Exit 8. Monitor Time settig Touch Manual Monitor item on main menu page to get into camera switch mode, select Monitor Time Set... item. touch ▲ / ▼ icon to increase / decrease the value; After finish, touch icon to save and exit.(touch icon to cancel the setting and return last page, touch icon to get into main menu page) Monitor Time Select Current : Cancel Home 01min Save&Exit 6 9. Restore to Default Touch User Setup item on main menu page to enter setup page,then touch Next Page item to enter User Setup 2 page, touch Restore to default item ,a message will be asked to confirm the restore operation. If touch icon ,All settings will be restored to default, if you don't want to restore, touch icon to cancel the operation.(Note that the restore to default operation will not change the time setting and the datas.) User Setup (2) Restore to Default Ring Volume ... Night Ring Volume ... TPC Configure ... Restore to default ... Last Page Restore all to default? Exit Are you sure to Cancel Home OK 10. Monitor Parameter Setting How to enter the installation setting page Main Menu Monitor ... Manual Monitor Intercom User Setup Close i About 1.Touch item on main menu page. H/W : S/W: Local addr: Unlock timing: Unlock2 select: Video standard: Language: DT14-CT a1.3 V17.11.418.00 ------- Exit 2.Touch the screen anywhere and hold for 2s. Input Code Number:[- - - -] 1 4 7 Exit * 2 5 8 0 3 6 9 # Home 3.A digital keypad will be showed. How to set the monitor as a Guard Monitor A Monitor can be assigned as Guard Unit Monitor; when the Guard Unit Monitor answers the call, conversation with the guard person is started.. The code number of 8004 is used to set the monitor as a guard unit monitor and 8005 is used to cancel this function. 7 How to set the slave monitor address Maximum 4 monitors can be connected in one apartment,one master monitor together with 3 slave monitors, so you should set the address correctly.(note:must have one monitor to be set as master monitor) The code of 8000 is used to set the master monitor. The code of 8001 is used to set the first slave monitor . The code of 8002 is used to set the second slave monitor . The code of 8003 is used to set the third slave monitor . Note:touch * button to cancel the input,touch # to save the settings. .How to set date and time format The system offers two methods of date and time. The code number of 8008 is used to set the date format as month/date/year The code number of 8009 is used to set the date format as date/month/year The code number of 8012 is used to set the time format as 12 hour system The code number of 8013 is used to set the time format as 24 hour system How to set the monitor panel on In default mode,when receive a calling,the master and slave monitors will ring at the same time,and just the master monitor can display the image while the slave monitors can not.But the settings can be changed,you can set the master monitor and all the slave monitors to panel on at the same time when receiving a call, just input the code number of 8006 on each slave monitor.    1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4     8 How to set the unlock parameter Unlock mode: There are two unlock modes: 1.power-on- to-unlock type:unlock mode=0(by default) 2.power-off-to-unlock:unlock mode=1. The code number of 8010 is used to set the unlock mode to 0 The code number of 8011 is used to set the unlock mode to 1 Unlock time: The unlock time can be changed by yourself at any time.it can be set from 1 to 9 seconds. The code number from 8021 to 8029 are used to set the unlock time to 1~ 9 seconds. How to set the menu language The monitor can support multi languages and it is so simple and fast, just input the corresponding language code on monitor.The language code number are as follows: 8101: English 8102: French 8103: Spanish 8104: Italian 8105: German 8106: Dutch 8107: Portuguese 8108: S-Chinese 8109: T-Chinese 8110: Greek 8111: Turkish 8112: Polish 8113: Russian 8114: Slovakia 8115: Hungray 8116: Czech Note:the monitor can only support 4 types of languages.English,French,Spanish and German are default.But you can customize any 4 languages by yourself.The language which is unavailable will be set to English in default. 9 11. Screen and Volume Adjustment During monitoring or talking, touch icon,the ADJUST MENU will be displayed. Touch and select the adjustment item you want; touch / icon to decrease / increase the value. 1. The first item is Scene mode selection: Total 4 screen modes can be selected in sequence: Normal, User, Soft and Bright. Whenever you modify Brightness or colour, Scene item will be set to User mode automatically. Scene Bright Color Ratio Talk Volume Exit Normal 6 6 16:9 2 Dec Inc 2. The Brightness and Colour item is for the image quality setting, adjust the value to get the best image you like. 3. The Ratio item is for screen display adjustment,you can set to 16:9 or 4:3. 4. The Talk Volume item is for talking volume adjustment. 5. Note that all the modifications will be performed immediately after the operation. Touch icon to exit the adjust page. 12. Specification ●● Power supply for indoor monitor: DC 24V ●● Power consumption: Standby15mA; Working 400mA ●● Monitor screen: 7 Inch digital color LCD ●● Display Resolutions: 800*3(R, G, B) x 480 pixels ●● Video signal: 1Vp-p, 75Ω, CCIR standard ●● Wiring: 2 wires, non-polarity ●● Dimension: 125(H)×225(W)×23(D)mm