2007 SELF-CONTAINED CASE ELECTRICAL AND REFRIGERATION REQUIREMENTS TABLE
MOBILE SELF-CONTAINED MERCHANDISERS
CASE MODEL MDCA-4' MDCA-6' MMCA-4' MMCA-6' MMCA-8' MMRA-2' MMRA-3' MMRA-4' MMRA-6' MPCA-8' OSIOA-4' deli OSIOPA-4' meat
OSIOA-P-4' OSIOZA-4' UPA-8' O2.5UMA-4'
(standard) (solid) (thermopane)
O3UMA-4'
56" Rear Sill 58" Rear Sill
OSIA-4' O2SIA-4'
SUCTION PRESSURE AIR 24 HR ENERGY @ CASE OUTLET REFRIGERANT TEMPERATURE (ºF) VELOCITY (1) USAGE (kWh) (PSIG) TYPE DISC. AIR RET. AIR (FPM) 16.6 52 R404A 25 36 295 52 R404A 25 36 295 17.2 49 R404A 24 35 140 49 R404A 24 35 140 49 R404A 24 35 140 15 R134A 29 39 180 15 R134A 29 39 180 15 R134A 29 39 180 15 R134A 29 39 180 19.9 R134A 30 42 163 14.1 12-14 R134A 26 34 182 13.6 20 R134A 34 36 200 18.0 16 R134A 32 36 200 32.0 12-14 R134A 26 34 182 25.0 12-14 R404A -24 -10 220 37.0 20 R134A 32 42 200 32.3 12-14 R134A 29 41 228 30.2 12-14 R134A 26 40 230 30.3 12-14 R134A 25 37 226 24.1 18-20 R134A 31 41 230 32.1 12-14 R134A 26 35 230 12-14 R134A 26 34 175 14.0 16 R134A 24 35 540
DEFROST SUPERHEAT SETPOINT Electric Timed Off @ BULB # DEF. Fail Safe Temp. Fail Safe Temp. o o (ºF) (Minutes) ( F) (Minutes) ( F) 6-8 4 35 47 ----6-8 4 35 47 ----6-8 3 35 47 ----6-8 3 35 47 ----6-8 3 35 47 ----6-8 4 30 47 ----6-8 4 30 47 ----6-8 4 30 47 ----6-8 4 30 47 ----6-8 3 40 49 60 47 6-8 4 40 47 ----6-8 2 40 47 ----6-8 2 40 47 ----6-8 2 40 47 ----3 -4 2 45 45 ----6-8 4 ----45 47 6-8 3 40 47 ----6-8 3 40 47 ----6-8 3 40 47 ----6-8 6 40 47 ----6-8 3 40 47 ----6-8 2 45 47 ----6-8 3 45 50 -----
PERMANENTLY CONNECTED SELF-CONTAINED MERCHANDISERS
CASE MODEL OPA-6' OPA-8' OPA-12' OWPA-8' O2.5UMA-8' ON5DMA-6' ON5DMA-8' O5DMA-4' O5DMA-6' O5DMA-8' ONN35UA-4' ONNA-47" ONUA-4' ONUA-6' ONIMA-8' ONIMA-12' ONIMBA-8' ONIMBA-12' OIMA-8' OIMA-12' OIMBA-6' OIMBA-12' OIPA-8' OIPA-12' (1)
SUCTION PRESSURE AIR 24 HR ENERGY @ CASE OUTLET REFRIGERANT TEMPERATURE (ºF) VELOCITY (1) USAGE (kWh) (PSIG) TYPE DISC. AIR RET. AIR (FPM) 19.9 R134A 30 45 210 19.9 R134A 30 45 210 19.9 R134A 30 45 210 19.9 R134A 30 45 210 40 R22 29 43 225 52 R404A 31 44 215 52 R404A 31 44 215 52 R404A 30 44 250 52 R404A 30 44 250 52 R404A 30 44 250 19.9 R134A 35 45 275 37.2 19.9 R134A 35 43 275 43.9 33 R22 28 39 310 59.3 33 R22 28 39 310 35 R22 25 34 180 35 R22 25 34 180 35 R22 25 34 180 35 R22 25 34 180 35 R22 26 31 140 35 R22 26 31 140 35 R22 26 31 140 35 R22 26 31 140 45 R22 34 48 140 45 R22 34 48 140
DEFROST SUPERHEAT SETPOINT Electric Timed Off @ BULB # DEF. Fail Safe Temp. Fail Safe Temp. o o (ºF) (Minutes) ( F) (Minutes) ( F) 6-8 2 40 47 60 47 6-8 2 40 47 60 47 6-8 2 40 47 60 47 6-8 2 40 47 60 47 6-8 3 40 47 45 45 6-8 4 ----42 47 6-8 4 ----42 47 6-8 4 ----42 47 6-8 4 ----42 47 6-8 4 ----42 47 6-8 3 40 47 ----6-8 6 ----40 47 6-8 4 ----40 45 6-8 4 ----40 45 6-8 3 35 47 ----6-8 3 35 47 ----6-8 3 35 47 ----6-8 3 35 47 ----6-8 3 40 47 ----6-8 3 40 47 ----6-8 3 40 47 ----6-8 3 40 47 ----6-8 3 ----44 38 6-8 3 ----44 38
Average discharge air velocity at peak of defrost.
Requirements comply with CRMA conditions. Due to Our Commitment to Continuous Improvement All Specifications are Subject to Change Without Notice. NR7060
Page-1 of 2 June-2007
2007 SELF-CONTAINED CASE ELECTRICAL AND REFRIGERATION REQUIREMENTS TABLE
MOBILE SELF-CONTAINED CASE MODEL MDCA-4' MDCA-6' MMCA-4' MMCA-6' MMCA-8' MMRA-2' MMRA-3' MMRA-4' MMRA-6' MPCA-8' OSIOA-4' OSIOPA-4' OSIOA-P-4' OSIOZA-4' UPA-8' O2.5UMA-4' O3UMA-4' 56" Rear Sill 58" Rear Sill
OSIA-4' O2SIA-4'
Volts 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120
Phase 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Hz 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
Plug Style NEMA L5-20 or NEMA 5-20 NEMA L5-20 or NEMA 5-20 NEMA L5-20 or NEMA 5-20 NEMA L5-20 or NEMA 5-20 NEMA L5-20 or NEMA 5-20 NEMA 5-20 NEMA 5-20 NEMA 5-20 NEMA 5-20 NEMA L5-20 or NEMA 5-20 NEMA L5-20 or NEMA 5-20 NEMA L5-20 or NEMA 5-20 NEMA L5-30 NEMA L5-30 NEMA L5-30 NEMA L5-20 or NEMA 5-20 NEMA L5-20 or NEMA 5-20 NEMA L5-20 or NEMA 5-20 NEMA L5-20 or NEMA 5-20 NEMA L5-20 or NEMA 5-20
Cord Length 10 ft 10 ft 10 ft 10 ft 10 ft 6 ft 6 ft 6 ft 6 ft 10 ft 10 ft 10 ft 10 ft 10 ft 10 ft 10 ft 10 ft 10 ft 10 ft 10 ft
PERMANENTLY CONNECTED SELF-CONTAINED CASE MODEL OPA-6' OPA-8' OPA-12' OWPA-8' O2.5UMA-8' ON5DMA-6' ON5DMA-8' O5DMA-4' O5DMA-6' O5DMA-8' ONN35UA-4' ONNA-47" ONUA-4' ONUA-6' ONIMA-8' ONIMA-12' ONIMBA-8' ONIMBA-12' OIMA-8' OIMA-12' OIMBA-6' OIMBA-12' OIPA-8' OIPA-12'
Volts 120 120 120 120 208 208 208 208 208 208 120 120 208 208 208 208 208 208 208 208 208 208 208 208
Phase 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Hz 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
Wire 2-wire + ground 2-wire + ground 2-wire + ground 2-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 2-wire + ground 2-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground 3-wire + ground
Minimum Circuit Ampacity 10.748 14.648 16.848 22.490 13.560 25.412 25.534 22.096 23.034 23.934 23.630 23.630 16.220 22.000 19.325 23.343 17.999 26.619 23.655 28.435 17.407 26.619 8.973 29.119
Requirements comply with CRMA conditions. Due to Our Commitment to Continuous Improvement All Specifications are Subject to Change Without Notice. NR7060
Maximum Overcurrent Protection 20 30 35 40 30 45 45 30 40 45 45 45 30 40 35 40 35 45 40 45 30 45 45 40
Page-2 of 2 June-2007