Preview only show first 10 pages with watermark. For full document please download

2010-6 Service Ls240hsv Higheffinverter System Mfl33984926 20120105132900

   EMBED


Share

Transcript

Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W243DGU1 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 1. Product Specifications Sales Model LS240HSV Models Unit kW Btu/h. kW Btu/h. W A A W/W Btu/h.W Cooling Capacity Heating Capacity Power Input Running Current Starting Current Cooling Cooling/Heating Cooling/Heating EER SEER HSPF Power Supply Power Factor Air Flow Rate Indoor,Max Outdoor,Max Moisture Removal Sound Level Indoor,H/M/L Outdoor,Max Refrigerant & Charge (at 7.5 m) Additional Refrigerant charge Compressor Fan(Indoor) Fan(Outdoor) Ø / V / Hz % m3/min(CFM) m3/min(CFM) l/h. dB(A)±3 dB(A)±3 g(oz) g/m(oz/ft) Type Model Motor Type Oil Type Oil Charge O.L.P. name Type Motor Output Type Motor Type Motor Output cc W W A No.*mm2 No.*mm2 mm(in) mm(in) mm(in) mm inch mm inch kg(lbs) kg(lbs) kg(lbs) kg(lbs) °C(℉) °C(℉) m(ft) m(ft) m(ft) Circuit Breaker* Power Supply Cable Power and Transmission Cable No.*mm2 Piping Connections Liquid Side Gas Side Drain Hose(O.D / I.D.) Indoor (W*H*D) Dimensions Outdoor (W*H*D) Net Weight Gross Weight Operation Range Piping Length (Min/Max) Chargeless Max. Elevation Difference Tool Code(Chassis) Functions Indoor Outdoor Indoor Outdoor Cooling(Outdoor) Heating(Outdoor) Indoor + Outdoor Temperature Control Allergy free filter Plasma Filter Prefilter(washable/anti-fungus) Auto Clean CHAOS Wind(Auto Wind) Steps, Fan/Cool/Heat Airflow Direction Control(up& Down) Airflow Direction Control(left & right) Remote Controller Type Setting Temperature Range Auto Operation (Micom Control) Auto Changeover (Micom Control) Self Diagnosis Timer Sleep Operation Soft Dry Operation Restart Delay(minute) Deice Control(Defrost) Hot Start Jet Cool Low Ambient Operation Special Function Note : O : Applie, X : Not applied, – : No relation • Filters are optional in some specific areas. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes Cooling Heating AS-W243DGU1 0.90 ~ 6.45 ~ 8.80 3,070~22,000~30,030 0.90 ~ 8.09 ~ 11.40 3,070~27,600~38,898 1760 7.9 / 10.7 7.9 / 10.7 3.66 12.5 18.9 10.2 1/208-230/60 96.9 25(883) 60(2,119) 2.8 46/43/39 54 R410A, 2,000(70.5) 35(0.38) Twin Rotary GJT240DAA Brushless DC Motor PVE(FVD68C) 900 Cross Flow Fan 76.1 Propeller BLDC 124 25 3*2.5 4*1.0 (Including Earth) 9.52(3/8) 15.88(5/8) 21.5 / 16.0(0.85 / 0.63) 1209*346*205 47-5/8*13-5/8*8-1/16 870*800*320 34-5/16*31-1/2*12-5/8 18(39.7) 60(132.3) 20(44.1) 64(141.1) -5~48(14~118.4) -10(-15)~24(14.0~75.2) - / 30(98.4) 15(49.2) SD + UE1+ Thermistor O O O O O 3/4/3 Auto Auto Wireless LCD(EZ-Remocon) 18°C ~ 30°C 16°C ~ 30°C O O 24h, On/Off O O 3 O O O O - • For Circuit Breaker Rating, please conform to local standards whenever necessary. -2- LGE Internal Use Only 2. Piping Diagrams Indoor Unit Outdoor Unit Liquid Side EEV 2-Way Valve Th2 Th1 Th4 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Th8 Th9 Th3 Th7 Gas Side 3-Way Valve Reversing Valve Accumulator Th5 Th6 Cooling Heating Compressor LOC. Description PCB Connector Th1 Thermistor for suction air temperature Th2 Thermistor for evaporator inlet temperature Th3 Thermistor for evaporator outlet temperature CN-TH2(Indoor) Th4 Thermistor for evaporator middle temperature CN-TH3(Indoor) Th5 Thermistor for discharge pipe temperature Th6 Thermistor for suction pipe temperature Th7 Thermistor for condensing temperature Th8 Thermistor for outdoor air temperature Th9 Thermistor for condensing middle temperature CN-TH1(Indoor) CN-TH3(OUTDOOR) CN-TH2(OUTDOOR) CN-TH4(OUTDOOR) ※ EEV : Electronic Expansion Valve Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -3- LGE Internal Use Only 3. Wiring Diagrams Indoor Unit RY-COMP(3) CN-U/D CN-12V CN-L/R CN-DISP3 CN-IN/N CN-HVB CN-DISP1 CN-TH1 CN-TH2 CN-TH3 CN-OPTION Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -4- LGE Internal Use Only Outdoor Unit Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -5- LGE Internal Use Only Exploded View Indoor Unit 135316 266001 135314 267110 152313 237900 733010 135511 131410 135500 342800 159830 152302 149304 354212 354210B 359011 135311 354210A 249951 35211B 346810 263230C 147582 146811B 135516 147582 145200A 266090 268711A Part for Plasma Model 352150 W6640 146811A 147581A Upper W0FZZ 147581B Lower 268711C 145200B 268711B W6640 263230B 567480A Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://biz.Lgservice.com,) Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -6- LGE Internal Use Only Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -7- 435301 437211 349480 437210 435512 447910 559010 346810 W4810 268711 152503 554160 552117 263230B 430410 549610 554031 137213A W6631A W0FZZ 552560 550140 552202 135500 W49810 552203B 552203A 55211G 661400 552200 561410 552116 435511A 649950 552115 435511B 137213B 552113 W6640 263230A 567480 352111B 435300 Outdoor Unit LGE Internal Use Only P/NO : MFL33984926 JUNE, 2010