Solar Power Solar Charge Controller Bonnie SCC-Basic • 12VDC or 24VDC available • Two-stage charging method • Lightweight design S o la r • Dual DC outputs: 12V/24V or 12V/6V • Microprocessor controlled guarantees high reliability • Compact size for standing and mounting flexibility • Supports solar powered devices and communication applications • Auto restart while AC is recovering • Off-mode charging • Overload protection and short circuit protection P o we r DC UPS / 12 V1 0A Bonnie DC UPS Selection Guide Solar Charge Controller Selection Guide MODEL CAPACITY INPUT Voltage Voltage Range Frequency Range OUTPUT MODEL INPUT Maximum PV Array Open Circuit Voltage Maximum PV Array Power Maxium Current OUTPUT Nominal Battery Voltage Connected Battery Type Maximum Charging Current Ripple Voltage Maximum Efficiency Standby Power Consumption Charging Method INDICATORS LED Display PHYSICAL Dimension, D x W x H (mm) Net Weight Connector Type of Mechanical Protection ENVIRONMENT Humidity Operating Temperature Storage Temperature Altitude COMPLIANCE Quality EMC Bonnie-30 30 W 230 VAC 160 VAC - 280 VAC 50 Hz Output Voltage Output Voltage Regulation 12 V 6V 24 V Transfer Time EFFICIENCY AC Mode Battery Mode BATTERY Battery Type Charging Voltage Charging Current Typical Recharge Time INDICATORS AC Mode Battery Mode Low Battery Fault PROTECTION Full Protection PHYSICAL Dimension, D x W x H (mm) (@ vertically stand) Net Weight (kgs) OPERATING ENVIRONMENT Humidity Temperature Dual output : 12 VDC / 6 VDC or 12 VDC / 24 VDC +15%, -12% ± 10% ± 5% 0 ms > 70% at nominal voltage (battery fully charged) > 90% 12 V 9 Ah x 1 13.7 V ± 0.25 V 3 A at nominal voltage without load; 0.7 A at nominal voltage with full load 4-6 hours recover to 90% capacity Green lighting Yellow lighting Yellow flashing Red lighting Short circuit and overload protection SCC-Basic-50 SCC-Basic-100 25 V 50 V 50 W 100 W 5A 12 V 24 V Sealed lead acid battery 5A <±1V 99.90% 0W Two stages: bulk and floating 1/floating 2 Green LED indicating charging status 27.5 x 38 x 63 50 g Input/Output terminal block IP 43 0 ~ 100% RH (No condensing) -20°C to 55°C -40°C to 75°C 0 ~ 3000 m ISO9001/ISO14001 EN61000-6-1, EN651000-6-3 * Product specifications are subject to change without further notice 228 x 82.5 x 207 3 0-90 % 0°C to 40°C * Product specifications are subject to change without further notice Advancing Power 20