Features • Multiple microprocessor and double-conversion design • Wide input voltage range • High input power factor • Cold start (DC power on) • LCD display panel • Lightening, surges, and disturbance protections • Multi- interface card options DS1000D(L) DS3000D(L)
Specifications
Front Panel
Model Name Topology On-battery Output Waveform Maximum Capacity INPUT Nominal Input Voltage Nominal Input Frequency Input Voltage Range OUTPUT Nominal Output Voltage Output Voltage Regulation Transfer Time (Typical) Start on Battery Auto Restart Number of Outlets PROTECTION Data Line Surge Protection Surge Energy Rating Overload Protection Over Current Protection Discharge Protection BATTERY Configuration Backup time (Full / Half load) Recharging Time to 90%
DS1000D(L) DS3000D(L) True On-Line, Double Conversion, High Frequency Pure Sine Wave 1KVA / 700W 3KVA / 2100W 110Vac (Option: 100/120Vac) / 220Vac (Option: 230/240Vac) 50Hz / 60Hz ± 4Hz 80-150Vac (100 / 110 / 120Vac) or 160-300Vac (220 / 230 / 240Vac) 220Vac (230V or 240V settable) 110Vac (100V,115V or 120V settable) Rated Voltage ±2% (on battery) 0 ms Yes Yes 3 Battery backup (NEMA 15A) 6 Battery backup (NEMA 15A) 4 Battery backup (IEC 10A) 3 Battery backup (IEC 10A) + Terminal
1
DS1000D(L) A
Audible Alarms COMMUNICATION INTERFACE Communication Port ENVIRONMENTAL Operation Temperature Storage Temperature Relative Humidity Acoustic Noise PHYSICAL in Dimensions W×H×D (Physical / Packing) mm DS-D lbs DS-DL lbs Weight (Net / Gross) DS-D kg DS-DL Kg Battery Pack Dimensions in W×H×D (Physical / Packing) mm lbs Battery Pack Weight kg
A
B
B
E
E
F
F
G
G H
D
H
D
C
C
(100 / 110 / 120Vac)
(220 / 230 / 240Vac)
DS3000D(L)
BP3000S (12V7.2Ah × 8 / 2 sets)
G
ADVANCED WARNINGS / DIAGNOSTICS Front Panel
2
Rear Panel
96V (12V / 7AH × 8) 5 / 15 min 5 Hours
BP1000S (12V/ 7.2AH × 3 / 2 sets)
Extended Battery Pack (Optional)
UP Down Enter
1
3
3
RJ11 295 Joules UPS shuts down at 115% load after 5 mins, 135% load after 30 secs or 150% load after 200m sec Circuit Breaker Keylock 36V (12V / 7AH × 3) 5 / 18 min
2
G
B
A
LCD: UPS status, I/O Voltage & Frequency, Load %, Battery Voltage, Battery Capacity %, Temperature, Event LED: Normal (Green), Warning (Yellow), Fault (Red) Battery mode / UPS fault / Overload
B
A
E
E F
F
RS232 (Options for SNMP card, AS 400, Dry Contact, USB)
H
0 ~ 40°C / 32 ~ 104°F -15 ~ 50°C / 5 ~ 122°F 0-95% Non condensing
H
<45dBA
<50dBA
5.9×8.6×15.7 / 10.6×13.7×20.8 150×220×400 / 270×340×530 31.9 / 36.4 15.4 / 20.9 14.5 / 16.5 7 / 9.5 6.3×8.7×15.7 / 9.1×12.8×19.7 160×220×400 / 230×325×500 42.6 / 44.5 19.3 / 20.2
7.9×13.8×17.7 / 13.4×19.3×22.1 200×352×450 / 340×490×560 77.1 / 86 33.1 / 41.9 35 / 39 15 / 19 7.9×13.8×17.7 / 14×19.5×23.8 200×352×450 / 355×495×605 103.6 / 107.4 47 / 48.7
D
C
C
(100 / 110 / 120Vac) A B C D E
RS232 Multi Card Slot Input Fuse External Battery (for Long backup models)
I
(220 / 230 / 240Vac) F G H I
Remote Control (Optional) FAX / Modem Surge Protection Output Output Terminal
* Specifications are subject to change without notice.
OPTI-UPS USA: Tel: +1-909-869-5700 Fax: +1-909-869-5730
[email protected] www.opti-ups.com
OPTI-UPS Australia & New Zealand: Tel: +64-9-441-6470 Fax: +64-9-441-6490
[email protected] www.opti-ups.com
OPTI-UPS Europe: Tel: +31-40-401-50-00 Tel: +31-40-262-80-57 Fax: +31-40-254-60-06
[email protected] www.opti-ups.com
OPTI-UPS Germany: Tel : +49-7071-5495-148 Fax: +49-7071-5495-149
[email protected] www.opti-ups.com
OPTI-UPS Middle East: Tel: +9714-8819-838 Fax: +9714-8819-938
[email protected] www.opti-ups.com
OPTI-UPS Japan: Tel: +81-3-3629-5782 Fax: +81-3-5682-0652
[email protected] www.opti-ups.com
OPTI-UPS Asia: Tel: +886-2-2246-7272 Fax: +886-2-2246-7312
[email protected] www.opti-ups.com.tw
©2011 OPTI International Corporation. Names and trademarks herein are the property of their respective companies.
USA / Australia & New Zealand / Europe / Germany / Middle East / Japan / Asia