Preview only show first 10 pages with watermark. For full document please download

2013 Es Sanitizer Technical Data

   EMBED


Share

Transcript

MALMET TECHNICAL SPECIFICATIONS Energy Saver Bed Pan / Flusher Sanitizer Product Range Issue 5 91-1000 ES910S Standard S Trap – 20amp 91-1005 ES910P Standard P Trap – 20 amp 91-1001 ES910S – D Standard Detergent S Trap – 20amp 91-1006 ES910P – D Standard Detergent P Trap – 20 amp 91-1020 ES930S Standard S Trap – 10 amp 91-1025 ES930P Standard P Trap – 10 amp 91-1021 ES930S – D Standard Detergent S Trap – 10 amp 91-1026 ES930P - D Standard Detergent P Trap – 10 amp Page 1 rd 23 August 2013 MALMET TECHNICAL SPECIFICATIONS Energy Saver Bed Pan / Flusher Sanitizer UNIT DIMENSIONS Cold Water Mains Inlet ¾” 595 Power Supply Lead 20 Amp Cold Water Tank 1305 1245 100 660 Control Panel Chamber 365 ‘S’ Trap Model Issue 5 Dimensions (mm) Height Width Depth ES910 1305 595 660 ES930 1305 595 660 Page 2 rd 23 August 2013 MALMET TECHNICAL SPECIFICATIONS Energy Saver Bed Pan / Flusher Sanitizer INSTALLATION AND SERVICE CONNECTION LAYOUT DETAILS Issue 5 Page 3 rd 23 August 2013 MALMET TECHNICAL SPECIFICATIONS Energy Saver Bed Pan / Flusher Sanitizer TECHNICAL SPECIFICATIONS POWER AND WATER CONSUMPTION DATA MODEL Avg Cycles per/Hr Avg Cycle min/sec Avg kWh per cycle CW Avg Lt per cycle 13.7 4.2 0.226 25 ES910S-D/ES910P-D 20A DETERGENT 11 5.30 0.300 36 ES930S/ES930P 10A STD 8.7 7.00 0.204 24.5 ES930S-D/ES930P-D 10A DETERGENT 7.7 7.50 0.236 35.05 ES 910S/ES910P 20A STD NOTE: Values may change due to operating and supply service conditions. Issue 5 Page 4 rd 23 August 2013 MALMET TECHNICAL SPECIFICATIONS Energy Saver Bed Pan / Flusher Sanitizer TECHNICAL SPECIFICATIONS Description Model ES910 ES930 240 / 50 / 1 240 / 50 / 1 Electrical Rating Voltage / Hz / Ph Amps 20 10 Temperature Environment operating conditions +10°C to +25°C Relative Humidity +30% to 70% Control PCB Microprocessor Controlled Access Vis Corn Port SK4-RS232 Microprocessor Controlled Access Vis Corn Port SK4-RS232 20 sec 20 sec Time Variable depends on water temp Time Variable depends on water temp 1 min and 5 sec 1 min and 5 sec 15 sec 15 sec 4 min 20 sec (approx) 7 min (approx) Initial Flush 10 sec 10 sec Detergent pump 9 sec 9 sec Rinse 3 sec 3 sec Pause 40 sec 40 sec Rinse 10 sec 10 sec Time Variable depends on water temp Time Variable depends on water temp Sanitation =>90c 1 min 5 sec 1 min 5 sec Cool Down Rinse 15 sec 15 sec 5 min 30 sec (approx) 7 min 50 sec (approx) 1 x Rotating 180° Nozzle 1 x Rotating 180° Nozzle 2 x Fixed 60° Nozzles 2 x Fixed 60° Nozzles 2 x Fixed 0° Urinal Nozzles 2 x Fixed 0° Urinal Nozzles 1 x Fixed 60° Nozzle 1 x Fixed 60° Nozzle Type Cycle and Times Standard unit Initial Flush Steam Heat Up Sanitization Cool Down Rinse Cycle Complete Cycle and Times Detergent unit Steam heat up Cycle Complete Spray System Main Wash Cool Down Steam Generator Capacity 2.3 Litres 1.11 Litres Material Stainless Steel 316 Stainless Steel 316 Temperature Control Sealed Stainless Steel Temperature Probe Sealed Stainless Steel Temperature Probe Water Inlet fill 240 V 50Hz Solenoid (Hot/Cold Water) 240 V 50Hz Solenoid (Hot/Cold Water) 20mm Outlet to Trap 20mm Outlet to Trap Screw In Screw In 4.5kw 2.2kw Overflow Protection Steam Generator Element Type Rating Over temperature protection Thermal cut-out switch 3 pole set point 115°C Manual reset Cold Water Supply Inlet Inlet Valve Cold water supply 240 Volt Solenoid G3/4 male 240 Volt Solenoid G3/4 male 5-25 deg C @ 100-400kpa 5-25 deg C @ 100-400kpa Cold Water Tank (Backflow Air break AS2845) Issue 5 Page 5 rd 23 August 2013 MALMET TECHNICAL SPECIFICATIONS Energy Saver Bed Pan / Flusher Sanitizer Capacity 19.5 Litres Material Overflow Protection 19.5 Litres 6mm PE 6mm PE 40mm Outlet via integrated S trap 40mm Outlet via integrated S trap Water Pump Type Horizontal multistage Horizontal multistage Capacity 116.7L/Min - 7 m³/hr at 23m Head 116.7L/Min - 7 m³/hr at 23m Head Rating 0.75kW 240 Volts 50Hz 4.2 Amps 0.75kW 240 Volts 50Hz 4.2 Amps Detergent Pump (in Detergent Units only) Type Self Priming Measuring Roller Cam Self Priming Measuring Roller Cam 30ml / Cycle 30ml / Cycle 240 Volt / 3.5A / 50HZ 240 Volt / 3.5A / 50HZ Capacity Rating Wash Chamber Material 304/4 Stainless Steel Seal Capacity 304/4 Stainless Steel Silicone Gasket Silicone Gasket 2 x Urinal Bottles + Bed Pan + Lid OR 2 x Urinal Bottles + Bed Pan + Lid OR 2 x Urinal Bottles + Commode Bowl + Lid OR 2 x Urinal Bottles + Commode Bowl + Lid OR 2 x Urinal Bottles + Standard Small Slipper Pan + Lid 2 x Urinal Bottles + Standard Small Slipper Pan +Lid S or P Trap S or P Trap Soil Line Connection Type Material 6mm PE 6mm PE 100mm I.D 100mm I.D Flange & Gaskets with Stainless Steel Bolts Flange & Gaskets with Stainless Steel Bolts Size Fitted to Chamber by Frame Material Fasteners – Frame/Body Feet Stainless Steel Stainless Steel 3/16” Rivets Stainless Steel 3/16” Rivets Stainless Steel 100mm Stainless Steel Adjustable with Screw Down Holes 100mm Stainless Steel Adjustable with Screw Down Holes N/A N/A Vent No vent Required Noise Level Door Open / Close 57dBA Average at 1m 57dBA Average at 1m Cold Water Flush 75dBA Average at 1m 75dBA Average at 1m Cold Water Fill 58dBA Averaged at 1m 58dBA Averaged at 1m Sanitization 40dBA Averaged at 1m 40dBA Averaged at 1m Final Rinse 56dBA Average at 1m 56dBA Average at 1m 110kg 110kg Unit Weight Shipping Transport and Storage Fragile Environment transport conditions Detergent: Malmet specific (5Lt) Issue 5 Keep away from rain Temperature +10°C to +40°C Do not stack Relative Humidity +30% to 75% Detergent concentrate Caustic Alkaline (ARTGC Class 1) Page 6 rd 23 August 2013 MALMET TECHNICAL SPECIFICATIONS Energy Saver Bed Pan / Flusher Sanitizer WIRING DIAGRAM – STD 20 AMP Issue 5 Page 7 rd 23 August 2013 MALMET TECHNICAL SPECIFICATIONS Energy Saver Bed Pan / Flusher Sanitizer WIRING DIAGRAM – 20 AMP DETERGENT Issue 5 Page 8 rd 23 August 2013 MALMET TECHNICAL SPECIFICATIONS Energy Saver Bed Pan / Flusher Sanitizer WIRING DIAGRAM – STD 10 AMP Issue 5 Page 9 rd 23 August 2013 MALMET TECHNICAL SPECIFICATIONS Energy Saver Bed Pan / Flusher Sanitizer WIRING DIAGRAM – 10 AMP DETERGENT Issue 5 Page 10 rd 23 August 2013 MALMET TECHNICAL SPECIFICATIONS Energy Saver Bed Pan / Flusher Sanitizer Issue 5 Page 11 rd 23 August 2013