Preview only show first 10 pages with watermark. For full document please download

2016 Powerpoint Templates

   EMBED


Share

Transcript

© Copyright 2016 EMC Corporation. All rights reserved. 1 VIPR SUITE WHAT’S NEW IN VIPR CONTROLLER AND VIPR SRM PUNEET LAL, DAN NORTON, AND GUEST CUSTOMER JAMES CODER © Copyright 2016 EMC Corporation. All rights reserved. 2 VIPR CONTROLLER 3.0 PUNEET LAL © Copyright 2016 EMC Corporation. All rights reserved. 3 MANAGING STORAGE LIFECYCLE CHALLENGES  Cost of managing heterogeneous storage  Lead times associated with storage allocation  Storage outages due to human errors  Storage integration with automation tools & cloud stacks  Storage Capacity and performance metrics across data center © Copyright 2016 EMC Corporation. All rights reserved. 4 CHOICE WITHOUT COMPROMISE ONE EXTENSIBLE SOFTWARE PLATFORM TO UNITE ALL STORAGE SELF-SERVICE PORTAL Automate Storage Best Practice Reduces manual tasks up to 89% & 73% of cost OPEN REST APIs SERVICES 100% Open & Extensible SAN & STORAGE OPERATIONS HIGH AVAILIBILTY DISASTER RECOVERY MIGRATION PROTECTION Support EMC & Non-EMC Platforms POLICY BASED STORAGE BEST PRACTICES More than 50 storage platforms supported SOUTHBOUND SDK VCE XTREMIO IBM XIV VMAX IBM SVC VNX Hitachi G1000 VBLOCK HP 3PAR © Copyright 2016 EMC Corporation. All rights reserved. Both Northbound and Southbound VPLEX ISILON DATA DOMAIN SCALEIO NETAPP Dell Storage Center Solidfire IBM DS8000 Plugs into ANY Cloud Stacks e.g., VMware, Microsoft, OpenStack 5 MANAGING APPLICATION STORAGE Storage Considerations DB1 Log1 DB2 Log 2 • • • • • • • Provision and place the applications on the right class of storage Manage federated application and dependencies between applications Manage Application snaps/clones for data protection and repurposing Setup storage replication & storage constructs for HA and DR Perform migration to load balance or for tech refresh Mount application devices for hosts Keep track of application and there devices for addition and deletion Primary Site ViPR-C Application Construct DB1 Log1 DB2 Log 2 • Provides flexibility to layout applications without the need to have deep understanding of underlying storage array/technology • Manage application and federated application data • Group associated storage array LUNs or FS • Take snapshots of whole/subset of application data • Export all application data to host(s) DR Site © Copyright 2016 EMC Corporation. All rights reserved. 6 MIGRATION WORKFLOWS Need for Migration • Tech refresh – move data to a new array • Rebalance storage usage in the datacenter • Applications missing their SLA ViPR-C Mobility Groups • Group volumes to be migrated together in Mobility Groups • Group volumes by array, hosts/clusters, or volumes • Initiate migration via API or ViPR-C Catalog © Copyright 2016 EMC Corporation. All rights reserved. 7 VIPR CONTROLLER SOUTHBOUND SDK • Southbound SDK for partners and storage vendors to add support for their storage platform OPEN REST APIs SERVICES SAN & STORAGE OPERATIONS HIGH AVAILIBILTY DISASTER RECOVERY MIGRATION PROTECTION POLICY BASED STORAGE BEST PRACTICES SOUTHBOUND SDK • Implemented generic model to define and to process capabilities of storage arrays • SDK made available via the CoprHD project © Copyright 2016 EMC Corporation. All rights reserved. 8 DR OF VIPR CONTROLLER APPLICATION • Eliminate ViPR Controller single point of failure • Self-contained and platform agnostic data replication • Maintain up to 2 standby sites – ViPR-C internal database(s) are always synced/consistent across data centers • ViPR northbound API client autoredirected to active/standby based on DR status • Inter-site network latency < 150ms © Copyright 2016 EMC Corporation. All rights reserved. 9 VIPR CONTROLLER SUPPORTED ENVIRONMENTS CLOUD STACK SUPPORT VMWARE MICROSOFT OPENSTACK PROGRAMING REST API SELF-SERVICE UI MULTI-TENTANCY TENANT & PROJECT QUOTAS SERVCE CATALOG ROLE BASED ACCESS CONTROL ORDER APPROVAL PROCESS ORDER EXECUTION WINDOW ACCESS CONTROL LIST HOSTS VMWARE ESX WINDOWS LINUX AIX OTHERS PLATFORMS - NATIVE ISILON SCALEIO VCE VBLOCK SYSTEMS VMAX, VMAX3 VNX, VNXe XTREMIO DATA DOMAIN FILER HITACHI DATA SYSTEMS NETAPP – FILE IBM XIV PLATFORMS – VIA OPENSTACK NETAPP – BLOCK IBM SVC, DS8000 DELL EQUAL LOGIC HP 3PAR, LEFTHAND ORACLE SUN ZFS SOLIDFIRE DATA PROTECTION TECHNOLOGIES RECOVERPOINT VPLEX SRDF SWITCHES CISCO BROCADE © Copyright 2016 EMC Corporation. All rights reserved. 10 VIPR SRM 4.0 DAN NORTON © Copyright 2016 EMC Corporation. All rights reserved. 11 NEXT GENERATION NAVIGATION Simplify and standardize navigation. Provide high level summary dashboards with actionable content. © Copyright 2016 EMC Corporation. All rights reserved. 13 WHY NEXT GEN NAVIGATION? We started by simplifying the tree view © Copyright 2016 EMC Corporation. All rights reserved. Dramatically reduces navigation from 13+ levels to just 3 clicks 14 EASILY MOVE FROM SUMMARIES TO DETAILS Click the chart title to see supporting details for the graph Everywhere a CI name shows up, it’s a hyperlink to that device’s CI Dialog © Copyright 2016 EMC Corporation. All rights reserved. Everything you need to know about a device is available in this dialog. You only have to go to the Report Library to see reports across many devices. 15 NEW TABBED REPORT UIS Converted CI Categories to Tabs, leaving more space for topology maps and simplifying page navigation Same top level tabs for every CI © Copyright 2016 EMC Corporation. All rights reserved. 16 SOLUTIONPACK NORMALIZATION Now every SP has the same use-case oriented categories! Previously, each SolutionPack had a unique menu structure… © Copyright 2016 EMC Corporation. All rights reserved. 17 GROUP FILTERING © Copyright 2016 EMC Corporation. All rights reserved. Filters for Device Grouping, Location, Customer, and Business Unit 19 Critical Alerts Dashboard Click to get details of the alerts © Copyright 2016 EMC Corporation. All rights reserved. 20 Amazon S3 support Detailed consumption and billing information for data stored on Amazon’s cloud service © Copyright 2016 EMC Corporation. All rights reserved. 21 RECOVERPOINT SUPPORT VMAX Supported Platforms: VMAX, VNX, XtremIO LUN (Gold, 10GB) RecoverPoint Appliance Application Cluster VNX LUN (Silver, 10GB) © Copyright 2016 EMC Corporation. All rights reserved. Chargeback: Primary = 10 GB Gold Total = 10 GB Gold, 10 GB Silver 22 RECOVERPOINT SUPPORT VNX LUN Remote VNX Mirror View LUN (Gold, 10GB) (Gold, 10GB) RecoverPoint Appliance Application Cluster VNX LUN (Silver, 10GB) Chargeback: Primary = 10 GB Gold Total = 20 GB Gold, 10 GB Silver  © Copyright 2016 EMC Corporation. All rights reserved. 23 Local Host Agent (Linux/Unix) Deploy Physical Host SP Agentless Collection Script onto servers Schedule via CRON tab, then dump script output to a file on: • the host • a proxy server • Collector SRM picks up the file and inserts the data  © Copyright 2016 EMC Corporation. All rights reserved. 24 HOST CONTAINERS Host is created and appears in Explore. Details such as Host appears in topology memory, CPU will be blank. Provide Hostname, IP,reports and view and chargeback Port WWNs in a .csv file © Copyright 2016 EMC Corporation. All rights reserved. 25 ENCRYPTION/COMPRESSION • Can encrypt or compress data between any two components – Most useful for remote collectors • LZ4 compression of about 95% • TLS 1.2 encryption – Other protocols are supported • Configuration UI (LBA/LBC) – Works on 3.7 but no UI © Copyright 2016 EMC Corporation. All rights reserved. 26 REST API • Released with 4.0 • GETs only (read-only) • Properties, metrics, filters, time series, events – No topology • Uses Tomcat authentication /properties/values?filter=device%3D%27VNX1%27&fields=device,part,name { values: [ {"device": "VNX1", "part":"Processor1", "name"="CurrentUtilization"}, {"device": "VNX1", "part":"LUN1", "name"="TotalCapacity"}, ... © Copyright 2016 EMC Corporation. All rights reserved. 27 BOSTON SCIENTIFIC JAMES CODER © Copyright 2016 EMC Corporation. All rights reserved. 28 Storage Resource Manager as used by Boston Scientific James Coder Technology Architect Global Storage Team Information Technology 29 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Boston Scientific At a glance • 1 of the world’s largest medical device companies • $7.4 billion revenue - $22.7B Market Cap • Sales in more than 40 countries • $0.9 billion (12%) invested annually in R&D • 15,000+ patents • ~24,000 employees • 11 manufacturing facilities worldwide 30 o 3 Ireland (4,000+ employees) o 5 US o 1 Puerto Rica o 2 Costa Rica Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally 1. Adjusted net income excludes acquisition, litigation, divestiture, restructuring, and other charges. For reconciliations of our non-GAAP financial measures, please refer to the Investor Relations section of our website at www.bostonscientific.com Six Core Businesses Interventional Cardiology $2.3 bn Neuromodulation $0.4 bn Endoscopy $1.2 bn Cardiac Rhythm Management $2.1 bn Peripheral Intervention $0.8 bn Urology and Women’s Health $0.5 bn 31 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally SRM at Boston Scientific • • • • Started with ECC in 2006 timeframe Started install of 3.x SRM in 1Q2014 Completed upgrade to 3.7.1 in 1Q2016 SRM Monitoring following hardware – Hardware VMAX 2/3 VNX 1, 2, e Xtrem10 Isilons Data Domain Switches Servers 32 Count 10 22 9 12 18 160 16 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Initial Deployment of SRM at Boston Scientific Needham Galway 33 Maple Grove Tokyo Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally SRM Deployment at Boston Scientific Primary backend Secondary backend (2) Collectors (11) Report Server 34 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally SRM at Boston Scientific Storage and Fabric Capacity Planning • 160 Switches / Access Gateways globally • 8,000 + gbics/sfp • Provides quick status via Operations Panel • Removes the dreaded life by spreadsheets for upgrades • Shows storage code levels • Great for tacking down EMC Security Advisories • Planning upgrades 35 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Storage Capacity Planning 36 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Fabric Capacity Planning & Auditing 37 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Storage Frame Auditing Array Serial Number Model Firmware MAPXIOCL1 MAPXIOCL2 mapxiocl3 NATXIOCL2 GALXIOCL1 mapxiocl4 NATXIOCL1 stpxiocl1 TDCXIOCL1 APM00141278938 APM00141819489 FNM00152600395 APM00141337162 CKM00152402913 FNM00154600194 APM00141338514 CKM00142601272 CKM00151201822 2X10TB 2X20TB 1X20TB 2X20TB 1X20TB 1X40TB 2X10TB 1X20TB 1X20TB 4.0.1-41_hotfix_1 4.0.1-41_hotfix_1 4.0.1-41_hotfix_1 4.0.1-41_hotfix_1 4.0.2-80 4.0.2-80 4.0.2-80 4.0.2-80 4.0.2-80 Array Serial Number Model Enginuity / Microcode VMAX20K 000192606027 VMAX40K 000195700967 VMAX40K 000195700968 VMAX40K 000195701061 VMAX40K 000195701037 VMAX-1 000292602193 VMAX100K 000296800187 VMAX20K 000192606054 Boston Scientific Confidential -- For Internal Use Only. 38 VMAX40K 000195702003 VMAX20K 5876.268.174 date:02.19.2015 patch_date:02.19.2015 VMAX40K 5876.268.174 date:02.19.2015 patch_date:02.19.2015 VMAX40K 5876.268.174 date:02.19.2015 patch_date:02.19.2015 VMAX40K 5876.268.174 date:02.19.2015 patch_date:02.19.2015 VMAX40K 5876.268.174 date:02.19.2015 patch_date:02.19.2015 VMAX-1 5876.268.174 date:02.19.2015 patch_date:02.19.2015 VMAX100K 5977.596.583 date: 06022015 patch_date: 06022015 VMAX20K 5876.268.174 date:02.19.2015 patch_date:02.19.2015 Do Not Copy, Display or Distribute Externally VMAX40K 5876.288.195 date:02.11.2016 patch_date:02.11.2016 SRM Operations Management • Identify issues quickly • Pin-points issue to switch level • Identify hot spots on storage frames • Ability to create custom notifications when needed 39 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally SRM Operations Management 40 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Fabric Overall Health 41 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally VMAX hot spots 42 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Events / Alerts / Notification - Customized • Isilon SyncIQ notifications – – – – – 43 Current Isilon software has no notification Modified Isilon Software Process Alert Traps on Event name and “fullmsg” text Sends Email to support groups for notification Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Deployed Thresholds – XtremIO Metric EMC Best Practice Total Front End IOPS Total Bandwidth Array Response Time (ms) Normal Array Response Time (ms) Minor Array Response Time (ms) Major Array Response Time (ms) Critical 150K IOPS *+ 500 MB/s *+ ~1-2 ms 150K IOPS *+ 1 GB/s *+ =< 2 ms Minor(2-5ms) Major(5-10 ms) Critical > (10ms) Pool Capacity Util % - Green <95% =< 85% ** Pool Capacity Util % - Yellow Pool Capacity Util % - Red 95% - 97% >97% = > 86 - 96% ** = > 97% ** * - per Xbrick + 50/50 read/write mix 4k block ** User configurable 44 SRM Metrics deployed today Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Benefits Benefits • Manpower savings – Estimated 1500 man-hours / year saved – Monthly Metric reporting – Semi Annual firmware and code upgrades – Ad-hoc reports for capacity planning for management • Good standard reports – Easy to customize • Licencing verification • Maintenance inventory simplification • SRM Upgrade simplification in 3.7 – Literally download package and distribute – Each release better than the last • 4.0 Development team is listening to our inputs 45 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Lessons Learned & Next Steps for BSC Lessons Learned • Don’t dive in too early, not all products are mature • Understand the benefits and work involved clearly – common sense • Get grip early on the scale of the people and hardware required to support. Next Steps • Adding hosts (ESXi) • Testing next generation of SRM • Interfacing with BMC’s Global Monitoring tool • Install Chargeback solution pack 46 Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Special Thanks • Special mention to EMC Team – – – – – 47 Leann Erlien Dylan Thornton Steven Raske Glenn Davis Yassir Laraki Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally ? © Copyright 2016 EMC Corporation. All rights reserved. 48 Thank You © Copyright 2016 EMC Corporation. All rights reserved. 49