Preview only show first 10 pages with watermark. For full document please download

2016 Powerpoint Templates

   EMBED


Share

Transcript

© Copyright 2016 EMC Corporation. All rights reserved. 1 MAINFRAME: WHAT'S NEW IN MAINFRAME ENABLERS AND UNISPHERE FOR VMAX TONY NEGRO © Copyright 2016 EMC Corporation. All rights reserved. 2 TOPICS • VMAX3 support in MFE 8.0 – 4 byte device support – GNS, QoS and DCP Commands • General Pool Management Enhancements – Virtual (thin) Pools – Storage Groups and FAST Service Level Provisioning • Replication – SRDF, MultiCycle Mode and Host Component – TimeFinder SNAPVX • Unisphere for VMAX 8.2 © Copyright 2016 EMC Corporation. All rights reserved. 4 MAINFRAME ENABLERS 8.0 © Copyright 2016 EMC Corporation. All rights reserved. 5 4 BYTE DEVICE SUPPORT • VMAX3 is capable of supporting >64K TDEVs in the future – Up to 64K used 2 byte device numbers x’FFFF’ – >64K devices requires 4 Byte device numbers x’FFFFFFFF’ • MFE components and SYMAPI-MF now support for 4 byte device numbers as of MFE 8.0 • Displays and messages may use 6 characters in some products © Copyright 2016 EMC Corporation. All rights reserved. 6 GROUP NAME SERVICES SCALABILITY • GNS is used to define and share host-defined device group information (GNS groups) across hosts • GNS currently uses a ‘scratch area’ in VMAX cache to store GNS group information, which has the following limitations – Fixed size that cannot be easily expanded – Coarse serialization that leads to performance issues • GNS in VMAX3 uses Symmetrix File System • Improved Scalability to 100,000 groups (8K group size) – Improved performance • Note: SRDF/AR replacement pools (SARPOOLS) are no longer supported in V3. GNS support for these has been removed © Copyright 2016 EMC Corporation. All rights reserved. 7 PRIORITY QOS AND DCP REMOVAL • Priority QoS is removed beginning with 5977 HYPERMAX OS • The following commands have been removed from MFE – DISPSPC – DISPDEVP – SETSPC – SETDEVP • Dynamic cache partitioning commands have been removed from MFE – DISPCCFG – SETCACHE – DISPCDEV / DISPCDV – SETCPADD – DISPCDVG/ DISPCDV – – DISPCGRP SETCPDEL SETCPMOD – DISPCGEN – SETCPMRP – DISPCUSE – – SETCPMVD/SETCPMV © Copyright 2016 EMC Corporation. All rights reserved. 8 GENERAL POOL MANAGEMENT IN MFE • GPM (MFE 7.6) background – GPM in ResourcePak Base supports management of the following pool types • THIN (for TDEVs) • SNAP (for TF/Snap save device) • DSE (for SRDF/A DSE ‘spillover’ devices) – SCF provides capacity consumption monitoring for all three pool types – GPM does not provide any FAST VP controls © Copyright 2016 EMC Corporation. All rights reserved. 9 Disk Group VIRTUAL (THIN) PROVISIONING CONCEPT • • • Storage capacity is structured in data pools defined by RAID protection, drive technology, rotational speed Thin devices are logical volumes that are provisioned to hosts Workload is spread across all disks Host addressable device (CUUA) STORAGE RESOURCE POOL © Copyright 2016 EMC Corporation. All rights reserved. Thin Device (TDEV) Thin Device Bound to Pool (BIND) Thin Pool Data Devices (TDAT) 10 STORAGE RESOURCE POOL • A Storage Resource Pool (SRP) is a collection of data pools that make up a FAST Domain – A data pool can only be included in one SRP • SRPs are defined in the BIN file – Not configurable by the customer • The factory preconfigured array included one SRP that contains all the data pool in the array • Multiple SRPs can be configured at the site however.. – EMC recommends the use of a single SRP © Copyright 2016 EMC Corporation. All rights reserved. 11 GENERAL POOL MANAGEMENT ENHANCEMENTS • Support for THIN only (via new constructs) – THIN, DSE, and SAVE pool management controls and monitors remain for Enginuity 5876 • Support added for managing the following VMAX3 provisioning constructs – Storage Resource Pool (SRP) – Service Level (SL) – Storage Group (SYMSG) • Note: Concept of TDEV BIND is removed • SRP, TDATs, TDAT pools (data pools) and Disk Groups are preconfigured at factory – User defines TDEVs (Unisphere or EMC Services), configures them into Storage Groups, and associates Storage Group with Service Level via GPM (or Unisphere) © Copyright 2016 EMC Corporation. All rights reserved. 12 VMAX3 FAST ELEMENTS STORAGE GROUPS app SERVICE LEVEL app app app app DIAMOND STORAGE RESOURCE POOL app app app app app app OPTIMIZED app app app app app BRONZE STORAGE RESOURCE POOL 0 (DEFAULT) VIRTUAL POOLS PHYSICAL DISK GROUPS app POOL 1 RAID 5 (3+1) DISK GROUP 1 1200 GB EFD © Copyright 2016 EMC Corporation. All rights reserved. POOL 2 RAID 6 (6+2) DISK GROUP 2 1.2 TB 10K SAS 13 MFE 8.0 ADDED QUERY COMMANDS DISKGRP POOLS © Copyright 2016 EMC Corporation. All rights reserved. 14 MFE 8.0 ADDED QUERY COMMANDS SRP © Copyright 2016 EMC Corporation. All rights reserved. 15 QUERY SYMSG © Copyright 2016 EMC Corporation. All rights reserved. 16 SAMPLE SETUP AND QUERY The devices not in a SG will default to “Optimized” SL! © Copyright 2016 EMC Corporation. All rights reserved. 17 ENHANCED SRDF REMOTE REPLICATION • Overall SRDF Enhancements – – – – Lower response times Leverage Multiple cores and threads More Ports/Groups per RDF director 16Gb/s support - 4 port I/O Module • SRDF/A Resiliency Improvements – Multi Cycle Mode – Improved RPO predictability © Copyright 2016 EMC Corporation. All rights reserved. 18 NEW SRDF/A MULTI-CYCLE MODE (MCM) Primary VMAX N N-1 ... N-M Secondary VMAX WAN N-M N-M-1 R2 • Allows more than two Delta Sets on Primary Site • Cycle are More Granular with Incremental Updates • Cycle switch occurs at Min Cycle Time, regardless • RPO at target is now more Granular & Predictable © Copyright 2016 EMC Corporation. All rights reserved. 19 MULTI-CYCLE MODE Prior mode is now called ‘legacy’ mode MSC requires all VMAXs to be 5977 for MCM mode MCM mode requires 5977 at both sites SRDF HC SQ SRDFA display indicates Legacy(L) or MCM (M) mode • DSE changes • • • • – DSE eliminated at R2 side – DSE is enabled by default on R1 to an SRP – No read from R2 when DSE is active • Group Write Pacing, if enabled, will pace at DSE spillover rate © Copyright 2016 EMC Corporation. All rights reserved. 20 SRDF MULTI PORT SUPPORT • 5977 now supports multiple ports (up to 16) per SRDF emulation instance • SRDF HC commands modified to operate on all ports of a director or a specific port • Commands that now include ‘port’ specification – – – SC LINK SQ LINK SC RDFGROUP • New command – SQ VIEWRA – shows all connection information between two systems starting at 5876 © Copyright 2016 EMC Corporation. All rights reserved. 21 REMOVAL OF SRDF ADAPTIVE COPY WP MODE • 5977 no longer supports AD Copy Write Pending mode for SRDF R1 – 5977 R2 devices can be the secondary of a 5876 5977 ADC-WP pair • SRDF HC actions that request a 5977 R1 be put in ADC-WP result in the ADC-WP mode being converted to ADC-DISK mode – Example actions: ADCOPY_WP, SWAP(ADCOPY_WP), CREATEPAIR(ADCOPY_WP) – IF this is not desired user must terminate Adaptive Copy mode with a NADCOPY • New Message for invalid requests: EMCCY10I ADCOPY_WP option not valid for config - converting to ADCOPY_DISK © Copyright 2016 EMC Corporation. All rights reserved. 22 MISCELLANEOUS SRDF HC CHANGES FOR VMAX3/5977 • SRDF HC supports SRDF connection between 5876 and 5977 (N-X) – Only Dynamic SRDF groups are supported in V3 • SRDF now supports HW compression on both FC and GigE SRDF • DSE is enabled by default and space is configured for it in the SRP • DSE space information in VMAX3 is now displayed via SRDF HC command #SQ SRDFA_DSE – DSE space is now in the SRP in VMAX, not a separate pool – Use of the Pool Management Utility no longer required to obtain information about DSE © Copyright 2016 EMC Corporation. All rights reserved. 23 SRDF HC SC VOL COMMAND PERFORMANCE IMPROVEMENTS • Problem: SRDF HC SC VOL operations on multiple ranges run excessively long • MFE 8.0 (and 7.6) have been enhanced to perform better on large ranges with 5875 and above • Applies to the following SC VOL operations – – – – – – – VALIDATE INVALIDATE REFRESH RFR-RSUM PREFRESH CREATEPAIR (KEEPR2, NOCOPY, DIFFERENTIAL) RESUMEPAIR(DIFF) © Copyright 2016 EMC Corporation. All rights reserved. 24 EASILY MANAGE MANY DATA COPIES NEW TIMEFINDER SNAPVX REDUCED IMPACT INCREASED AGILITY • Target-less Snapshots Production Volume Snapshot Snapshot Linked Target © Copyright 2016 EMC Corporation. All rights reserved. Snapshot • EASE OF USE • Up to 256 Snapshots per source • User-defined name/version number • Up to 1024 Linked Targets (snaps and/or clones) per source • Automatic expiration if desired Single architecture supporting: • • • TF/Mirror (via Clone Emulation) TF/Clone TF/SNAP (via VP SNAP for MF only) 25 UNISPHERE FOR VMAX INTRODUCING THE MAINFRAME DASHBOARD © Copyright 2016 EMC Corporation. All rights reserved. 26 TOPICS • Mainframe Dashboard • Splits View, CU Images View • Provisioning of SG with CKD Volumes • CKD Volume Creation support (Model Types) • Storage Group Dashboard – SRP CKD support – Storage Group Demand Report © Copyright 2016 EMC Corporation. All rights reserved. 27 MAINFRAME DASHBOARD • Launch from the Host tab • Shows CKD Storage Group Service Level Compliance • Common Tasks • Provision for mainframe • Create CKD volumes • Summary Views • Splits • CU images • CKD Volumes © Copyright 2016 EMC Corporation. All rights reserved. 28 MAINFRAME DASHBOARD SG Compliance Drilldown for details © Copyright 2016 EMC Corporation. All rights reserved. 29 SPLITS LIST VIEW © Copyright 2016 EMC Corporation. All rights reserved. 30 CONTROL UNIT IMAGES LIST © Copyright 2016 EMC Corporation. All rights reserved. 31 PROVISIONING WIZARD FOR MAINFRAME Emulation CKD 3390, 3380 Model Type -> Cly Size © Copyright 2016 EMC Corporation. All rights reserved. 32 PROVISION WIZARD FOR MAINFRAME Select CU Image © Copyright 2016 EMC Corporation. All rights reserved. 33 CREATE FAST-MANAGED CKD SG • • • • CKD Volumes List View Select CKD Volume range Create FAST managed CKD Storage Group Filtered SRP & SL for CKD Create SG © Copyright 2016 EMC Corporation. All rights reserved. 34 CKD VOLUME CREATE • Volume creation – Emulation option - CKD 3380 & CKD 3390 – Model Types support © Copyright 2016 EMC Corporation. All rights reserved. 35 z/OS MAP AND PAV DEFINITIONS • • • Select CKD Volume range Select z/OS Map Map selected CKD volumes to CU Image © Copyright 2016 EMC Corporation. All rights reserved. 36 UNISPHERE UPDATE – HEATMAP © Copyright 2016 EMC Corporation. All rights reserved. 37 UNISPHERE UPDATE zHPF INFO © Copyright 2016 EMC Corporation. All rights reserved. 38 UNISPHERE UPDATE – zHPF WRITES VS TOTAL © Copyright 2016 EMC Corporation. All rights reserved. 39 UNISPHERE UPDATE – PORTS © Copyright 2016 EMC Corporation. All rights reserved. 40 TOPICS COVERED • VMAX3 Overview Support in MFE • General Pool Management Enhancements – Virtual (thin) Pools – Storage Groups and FAST Service Level Provisioning • Replication – SRDF, MultiCycle Mode and Host Component – TimeFinder SNAPVX • Unisphere for VMAX 8.2 Mainframe-related enhancements © Copyright 2016 EMC Corporation. All rights reserved. 41 GET HANDS-ON @VLABS! TWO GREAT OPTIONS 1 CLASSIC SELF-PACED VLABS • • VMAX: Introduction to the VMAX3 Family VMAX: Performance Analyzer for the VMAX3 Family (also available as a Guided vLab – sign up req’d) 2 • • • • • © Copyright 2016 EMC Corporation. All rights reserved. MONDAY TUESDAY WEDNESDAY THURSDAY 9am 7am 7am 7am - 9pm 5:30pm 5:00pm 12pm (last seating @11am) VMAX SHORTS @The VMAX Hub A Shot of White Lightning – VMAX All Flash Introduction to Unisphere 360 Data Protection on the VMAX3 (SRDF/Metro & SnapVX) VVols Provisioning on VMAX3 Mainframe Provisioning on VMAX3 42 WANT TO WIN A BB8 DROID? FOLLOW & WIN! • Follow @EMCStorage or @EMCProtectData while at EMC World • 2 Winners will be chosen daily from Monday May 2 to Thursday May 5 • All winners will be notified through Twitter Direct Message ABBREVIATED RULES FOLLOW ME AND WIN EMC WORLD 2016 TWITTER SWEEPSTAKES ABBREVIATED RULES: NO PURCHASE NECESSARY. NOT OPEN TO THE GENERAL PUBLIC. Only open to individuals: [a] 21-years or older; [b] attending EMC World 2016 in Las Vegas, NV during May 2-5, 2016; [c] not residing in an Excluded Territory defined below; and, [d] with a personal Twitter account. ■ To enter, follow @EMCStorage or @EMCProtectData Twitter handle 8:00:00 am thru 5:30:00 pm on May 2-4, and 8:00:00 am thru 2:30:00 pm on May 5. All times are Pacific Time. New followers only may participate. Entries valid for each day’s drawing held after entry is received. One entry per person. ■ Two (2) winners randomly selected daily from all entries will each receive one (1) Sphero BB8 App Enabled Droid (ARV $149.95). Total ARV of all prizes is $1,199.60. ■ You can only win one prize. Odds of winning depend upon number of entries received prior to each drawing. You have not yet won. ■ IF YOUR COMPANY POLICIES OR APPLICABLE LAW PROHIBIT YOU FROM ACCEPTING THE PRIZE, YOU ARE INELIGIBLE. Employees, officials, or internally contracted vendors of any government, government-affiliated company or organization, and employees of EMC Corp. and its affiliates are ineligible. ■ VOID IN PUERTO RICO, AND OTHER USA TERRITORIES (EXCLUDING D.C.), QUEBEC, ARGENTINA, CHILE, PERU, AND WHERE PROHIBITED (collectively, “Excluded Territory”). ■ Actual prize may vary from prize as pictured. Prizes intended for USA market; may not be supported outside USA. ■ Other rules, exceptions, and limitations apply. Subject to Official Rules posted at http://thecoreblog.emc.com/followandwinsweepstakes/. See www.emc.com for Privacy Policy. ■ If you do not agree with the Official Rules, do not submit an entry. ■ Sweepstakes not associated with Twitter Inc. or prize manufacturer. ■ Sponsored by EMC Corp, 176 South St., Hopkinton, MA 01748, U.S.A. © Copyright 2016 EMC Corporation. All rights reserved. 43 © Copyright 2016 EMC Corporation. All rights reserved. 44 © Copyright 2016 EMC Corporation. All rights reserved. 45