Preview only show first 10 pages with watermark. For full document please download

201601041127080

   EMBED


Share

Transcript

JetNet 5012G Firmware Release Note JAN-2013 Korenix JetNet Industrial Managed Switch 5012G Software Release Notes Before Upgrade Before you use the Switch firmware, please ensure that you know the product number and use the correct firmware version. By reading the file, you can know the new feature and changes, the fixed bugs and the restrictions. You can find the latest firmware in the Korenix web site, http://www.korenix.com or get the help from Korenix Customer Support, [email protected] . About This Software Version The version number and the release date. Firmware ( Armboot) Release Date Model V1.4a (Armboot v1.0.0.4) JAN-2, 2013 JetNet 5012G Official Release V1.4 (Armboot v1.0.0.4) Dec. 12, 2012 JetNet 5012G V1.3a (Armboot v1.0.0.3) Dec. 05, 2011 JetNet 5012G V1.3 (Armboot v1.0.0.3) Nov. 03, 2011 JetNet 5012G V1.2b (Armboot v1.0.0.3) Jul. 06, 2011 JetNet 5012G V1.2 (Armboot v1.0.0.3) Mar. 17, 2011 JetNet 5012G V1.1b (Armboot v1.0.0.3) Dec 6, 2010 JetNet 5012G V1.1 (Armboot v1.0.0.3) May 6, 2010 JetNet 5012G CAUTION: You can only update the correct firmware to the JetNet switches. Ensure the product model number before you start updating. If the version of Boot Loader is not match the firmware, then upgrade firmware first before Boot Loader, ensure the power state is stable during the upgrade. You can upgrade firmware and boot loader through JetView commander. Important! Upgrade firmware shall follow the following sequence:  First, upgrade new version firmware by JetView utility  Secondary, upgrade new version Boot loader by JetView if Switch boot loader is old version. After Boot loader upgrade finished, it will auto restart system to enable the new functions. New Changes and Improvement: The following changes apply to the version v1.4a: ■ Add new features into Modbus TCP protocol  write single register function  write multiple register function  add clear RMON register  add media type register 1 JetNet 5012G Firmware Release Note JAN-2013 The following changes apply to the version v 1.4: ■ Clone history  JetNet5012G-v1.4_beta1 clones from JetNet4518-v1.4  JetNet5012G-v1.4 clones from JetNet5012G-v1.4_beta1 ■ Apply new boot loader v1.0.0.4 for supporting WINBOND W9825G6JH-6 ■ New Features:  Support IP v6  Web save function  Supports Port bAsed DHCP Server function with predefined IP address for Client request.  DHCP Server function with Option 82, and support relay agent DHCP Relay Agent can assign Circuit-IDand Remote-ID MAC address IP address Arbitrary strings  Changing SSH key and SSL certs  Enable/disable telnet and http service The following changes apply to the version v 1.3a: ■ ■ Clone history  JetNet5012G-v1.3a_beta1 clones from JetNet5012G-v1.3  JetNet5012G-v1.3a_beta2 clones from JetNet5012G-v1.3a_beta1  JetNet5012G-v1.3a_beta3 clones from JetNet5012G-v1.3a_beta2  JetNet5012G-v1.3a clones from JetNet5012G-v1.3a_beta3 add new feature of qos policy map according customer request  only providing class-default and set ip dscp, just like cisco  new CLI ■ fix the bug that gi11 and gi12 of JetNet5012g can't link up with sfp ■ fix the bug that shutdown command in config file is ineffective on fiber port The following changes apply to the version v 1.3: ■ Clone history  JetNet5012G-v1.3_beta1 clones from JetNet5012G-v1.2.10  JetNet5012G-v1.3 clones from JetNet5012G-v1.3_beta1 ■ Web supports Chinese simplified language ■ Add modbus tcp slave ■ Apply the new time setting format for daylight saving time ■ SFP 2 JetNet 5012G Firmware Release Note  Add sfp eject/scan function  Add sfp enable/disable ddm function  Add new sfp warning event JAN-2013 The following changes apply to the version v 1.2b: ■ Clone history  JetNet5012G-v1.2b_beta1 clones from JetNet5012G-v1.2  JetNet5012G-v1.2b_beta2 clones from JetNet5012G-v1.2b_beta1  JetNet5012G-v1.2b clones from JetNet5012G-v1.2b_beta2 ■ Replace fiber link first function by sfp plug first ■ Fix bug  JetNet6710G bug #375  JetNet5428G bug #468  JetNet5628G bug #798 The following changes apply to the version v 1.2: ■ Clone history  JetNet5012G-v1.2_beta1 clones from JetNet5012G-v1.1.38  JetNet5012G-v1.2_beta2 clones from JetNet5012G-v1.2_beta1  JetNet5012G-v1.2 clones from JetNet5012G-v1.2_beta2 ■ Add MSTP function ■ Add Private VLAN and QinQ function ■ Fix bug# 377, 443, 464, 465. The following changes apply to the version v 1.1b: ■ ■ Clone history  JetNet5012G-v1.1b_beta1 clones from JetNet5012G-v1.1  JetNet5012G-v1.1b clones from JetNet5012G-v1.1b_beta1 Fix bug#271, 275, 298. The following changes apply to the version v 1.1: ■ Clone from JetNet5012G-v1.0.19 ■ Fix bug#212 #261 #263 #264 #266. Fixes for Known Faults The following fixes apply to version 1.4a:  Fix DHCP Client issue that system will show wrong information sometimes. ( #573)  Fix CLI issue that perform “show interface: when Gi9,10 link up and the system reply both of Gigabit port work at half duplex mode. (#576)  Fix Private VLAN issue.(#577)  Fix Static IP configure issue that after DHCP client get IP successful, and then reconfigure IP by static IP 3 JetNet 5012G Firmware Release Note JAN-2013 address, then the system fault occurred. ( #581)  Fix DHCP server function issue. (JetNet5728G-24P #1131)  Fix IP IGMP Snooping function that reload to default does not working.(JetNet5728G-24P #1137)  Fix WEB PVLAN interface display shortage issue. (JetNet5728G-24P #1139)  Fix LLDP issue that 1st time will show wrong IP address, and after manual configured it becomes normal. (JetNet5710G #570)  Fix VLAN’s description saving issue. (JetNet5010G bug #1450) The following fixes apply to version v1.4  Fix warm /cold start syslog with wrong time stamp when enable NTP function(#290)  Fix PortMirrorMIB read issue ( #510)  The P-VLAN is suggest to apply SVL function.(#514)  Fix SNMPcontinuous polling leads SNMP agent send wrong information issue (#515)  Fix MnitorDiag Mib pulling caused systems response slow and fail issue (#516)  Fix ACL rule up 256 caused system crashed issue. (#524)  Fix DHCP On/off issue. (#546)  Fix remote syslog show additional information issue.( #556)  Fix password change issue.( #557)  Fix load default-ssl issue (#560)  Fix nameserver setting issue.( #562)  Fix QoS priority configure issue ( #564)  Fix slow system boot issue when system setting non-existed DNS and save reboot. ( #569)  Fix SNMP Walk search and couldn’t show OID issue. (#571)  Fix SNMPv3 polling fail issue when NTP sync enabled. (#1439)  Fix enable SNMPv3 will cause SNMP get server error when Switch system perform reset. (#1440)  Fix community issue. (#1442)  Fix Daylight Saving configure issue. ( #1448) The following fixes apply to version v 1.2  OID(1.3.6.1.4.1.24062.2.2.8.3.4.1) - stormControlTable cannot be modified. (bug#85)  OID(1.3.6.1.4.1.24062.2.2.8.3.5.1.1) - The table and CLI are not sync if we use mib to create a trunk group. (bug#86)  OID(1.0.8802.1.1.2.1.1.1~7) - LLDP mib cannot to be modified. (bug#97) Known Restrictions or Limitation  LACP Leader port removed, but the GVRP Packet will not forward from new leader port.(#79)  Static trunk with GVRP with wrong VLAN information. (#248)  MSR and LACP enabled together in some condition will issue occurred. (#249)  JetView cannot Backup/Restore and upgrade Switch’s firmware by Windows-7 platform. (#270) 4 JetNet 5012G Firmware Release Note JAN-2013  IP IGMP parameters auto disappear once perform backup configuration and reload the backup file.(#410)  In Some time, port 11,12 need reconfigure 2 times to 1000Mbps (#434)  MSTP enable, the ping command can’t reach device through port-1, unless remove VLAN-1 from Instance -1. (#487)  MSTP, RDH Enabled, PC can’t receive query from port-1, unless disable RDH function.(#488)  QoSPriorityMode & Port MirrorSourceTable MIBS have read issue. (#510)  在HCP request packet without requester’s IP address(#511)  Enable ModBus TCP with patch register read, the address range set to 125 ~50, scan rate set to 100ms, and telnet login, execute “show running-configure” command will cause software hang-up. (#519)  Enable IPv6, and creates many sessions by http, https and telnet, then it will show memory allocate information.(#550) 5