Transcript
Genesis® Series Cable
2017 LOW-VOLTAGE CABLE CATALOG
Our Commitment to You At Honeywell Cable, we strive to be the most trusted, go-to brand for low-voltage cable across a wide range of applications. By providing quality wiring products and responsive, reliable world-class service, our mission is to work with you to enable your success every day. Our industry-leading processes ensure you easily receive exactly what you need, when you need it, where you need it.
Complete Product Line
Works With You
Quality &
World-Class
Reliability
Service
Innovative Solutions
Table of Contents Introduction to Honeywell Cable ................................................................................................................................................................... 4 Most Popular Cables.................................................................................................................................................................................... 5 Part Numbers, Packaging and Color Codes ..................................................................................................................................... 12 Conductor Color Code Charts................................................................................................................................................................ 13 Security Cables | Article 725/800 .............................................................................................................................................................. 15 Plenum........................................................................................................................................................................................................... 16 CSA Listed .................................................................................................................................................................................................... 19 Riser ................................................................................................................................................................................................................ 20 General Purpose ......................................................................................................................................................................................... 22 Access Control Cables .................................................................................................................................................................................... 25 Plenum........................................................................................................................................................................................................... 26 Riser ................................................................................................................................................................................................................ 27 Video Surveillance Cables ............................................................................................................................................................................. 29 Network & IP Cables | Article 800 .............................................................................................................................................................. 33 Cat 6A ............................................................................................................................................................................................................. 35 Cat 6 Plus ...................................................................................................................................................................................................... 36 Cat 6................................................................................................................................................................................................................ 37 Cat 5e ............................................................................................................................................................................................................. 38 Cat 3................................................................................................................................................................................................................ 40 Fire Alarm Cables | Article 760 .................................................................................................................................................................... 41 Plenum........................................................................................................................................................................................................... 42 Riser ................................................................................................................................................................................................................ 45 General Purpose ......................................................................................................................................................................................... 48 Metal Clad .................................................................................................................................................................................................... 50 Direct Burial ................................................................................................................................................................................................. 51 CSA Listed .................................................................................................................................................................................................... 52 New York City Local Law 5 ...................................................................................................................................................................... 53 HVAC & Thermostat Control Cables .......................................................................................................................................................... 55 Hybrid............................................................................................................................................................................................................. 57 General Purpose ......................................................................................................................................................................................... 58 Plenum........................................................................................................................................................................................................... 59 Mini-Split ...................................................................................................................................................................................................... 60 Intelligent Building System (IBS) Cables ................................................................................................................................................. 61 BACnet/EIA-485 ........................................................................................................................................................................................ 62 Echelon® LonWorks® ................................................................................................................................................................................. 63 Lutron®........................................................................................................................................................................................................... 64 Irrigation/Tracer & Lighting Cables .......................................................................................................................................................... 65 Underground Lighting ............................................................................................................................................................................. 66 Irrigation/Tracer......................................................................................................................................................................................... 67 Audio/Video Cables ......................................................................................................................................................................................... 69 Audacious® Premium Audio ................................................................................................................................................................... 71 Home Theater Sound ................................................................................................................................................................................ 73 Video ............................................................................................................................................................................................................... 74 Multimedia Cables | Article 725 .................................................................................................................................................................. 77 Technical Data, Tools & Resources............................................................................................................................................................. 79 Index ..................................................................................................................................................................................................................... 87
Select the best cable for that… Insist on quality and reliability you can trust. Insist on Honeywell Genesis® Series Cable. Genesis Series low-voltage cables are produced with innovative equipment and technology in our state-of-the-art facility in Pleasant Prairie, Wisconsin. We offer a complete portfolio of quality cable to meet your business needs.
Cable for That! Apps – Information On the Go Insisting on quality and reliability you can trust means insisting on Honeywell Cable. When it’s time to select the best cable for your application, download the Security or HVAC Cable for That! mobile app and get all the answers you’re looking for.
Just another way of giving you the tools you need to succeed, these mobile apps are available on both Apple® and Android® devices.
4 | www.honeywellcable.com
Genesis® Series Cable
Most Popular Cables
Security
Page
Fire Alarm
Page
22/2 Solid CM/CL2
1101
22
22/4 Solid FPL
4101
48
22/2 Stranded CM/CL2
1102
22
18/2 Solid FPL
4106
48
22/4 Solid CM/CL2
1103
22
18/4 Solid FPL
4107
48
22/4 Stranded CM/CL2
1104
22
16/2 Solid FPL
4111
48
18/2 Stranded CM/CL2
1118
22
16/4 Solid FPL
4112
48
18/4 Stranded CM/CL2
1119
22
14/2 Solid FPL
4113
48
22/2 Stranded CMP/CL2P
3102
16
18/2 Solid FPLR
4306
46
22/4 Stranded CMP/CL2P
3104
16
18/4 Solid FPLR
4307
46
18/2 Stranded CMP/CL2P
3114
16
18/2 Solid FPLP
4506
42
18/4 Stranded CMP/CL2P
3115
16
18/4 Solid FPLP
4507
42
16/2 Solid FPLP
4511
42
Page
16/4 Solid FPLP
4512
42
14/2 Solid FPLP
4513
42
Video Surveillance RG59 BC Braid CL2
5001
32
RG59 CCA Braid + 18/2 CL2
6508
32
RG59 BC Braid + 18/2 CL2
5013
32
RG BC Braid + 18/2 CL2P
5355
31
16/2 Stranded AUDACIOUS® CL3R
Page
16/4 Stranded AUDACIOUS® CL3R
5474
71
16/3 Stranded CL3
5250
73 73
Access Control PROFUSION™ Unjacketed Bundle CMR/CL2R (22/6 OAS + 22/2 + 22/4 + 18/4) PROFUSION™ Unjacketed Bundle CMP/CL2P (22/6 OAS + 22/2 + 22/4 + 18/4)
2195
3195
27
26
Audio/Video
Page 5473
16/4 Stranded CL3
5251
RG6 Quad-Shielded CATV
5007
75
RG6 Dual-Shielded CATV
5003
75
Networking/IP HVAC/Thermostat
Page
Page
Cat 5e CM
6330
39
Cat 5e CMR
5078
38 38
5 Conductor Hybrid CL2
6713
57
6 Conductor Hybrid CL2
6714
57
8 Conductor Hybrid CL2
6716
57
10 Conductor Hybrid CL2
6718
57
18/2 Solid CL2
4710
58
18/3 Solid CL2
4711
58
18/4 Solid CL2
4712
58
18/5 Solid CL2
4713
58
18/6 Solid CL2
4714
58
18/8 Solid CL2
4716
58
Genesis® Series Cable
71
Cat 5e CMP
5088
Cat 5e Direct Burial
5090
39
Cat 6 CMR
6360
37
Cat 6 CMP
6361
37
Cat 6 Plus CMR
5092
36
Cat 6 Plus CMP
5102
36
Cat 6A CMR
5193
35
Cat 6A CMP
5393
35
www.honeywellcable.com | 5
Innovation that never stops At Honeywell Cable, we know our customers demand innovation, and they deserve it. This is what drives us to always work to make our products and services better. Our goal is clear: provide the most reliable products, easiest installations and robust support.
Here are just some of the ways we’ve recently responded with new, innovative technology: Category Cable – Responding to greater bandwidth and security demands, we have rounded out our line of network category cable to meet current and future technological requirements: • Cat 6A – for maximum bandwidth capable of handling 10G and 7G-wireless demands. • Cat 5e/6 Plus Shielded Options – for increasingly larger and more sensitive data applications. • Cat 6 (Yellow) – for a wider range of applications. HVAC Cable – When it comes to installing and connecting to HVAC systems, our cable is specifically engineered to handle evolving technologies and deliver exactly what our customers need: • Hybrid Thermostat – lighter weight cable is first designed specifically for power requirements of the circuit. • Metal Clad Mini Split – sunlight-resistant and suitable for direct burial – install without conduit. • Mini-Split 50' Convenience Packs – job-sized coils that simplify pricing, ordering and inventory. Fire Cable – Designed for optimal safety and manufactured in a wide variety of gauge sizes, shielding configurations and jacketing materials, including plenum, riser and general purpose: • Striped Fire Wire – easy to identify different cables without marking or tracing in a bundle. • Metal Clad Fire Wire (coming soon) - Dual-listed MC and FPL for NPLFA or PLFA fire alarm circuits – no need for conduit. Audacious® Sound Cable – 12-gauge option for longer run that rounds out our line of high-quality audio cable – providing optimal conductivity, signal integrity and ease of installation. Access Control Cable – As building access and control systems become more intelligent, it’s vital that the cable connecting them keep pace with technology. Our cable does just that: • Profusion – cost-effective, revolutionary twisting scheme to hold pairs together without binding. • Overall Jacket (OAJ) – easy to strip, snag-resistant, with countdown markings – for faster, hassle-free installations. Packaging – Working with installers rather than against them, our innovative cable packaging addresses common installation challenges, saving time, money and on-the-job headaches: • REACT™ Packaging – delivers consistent tangle-free performance. • Speed Bag® Packaging – save space, time and money, stacking multiple wires in a single bucket. • SPEED BOX® Packaging – for smoother, faster installations, it comes in Pull Box or Reel-In-A-Box. For more information please call 1-800-222-0060 or visit www.honeywellcable.com
6 | www.honeywellcable.com
Genesis® Series Cable
Innovations in Packaging REACT™ Packaging This innovative cable packaging addresses common installation challenges, working with installers rather than against them. With no adjustments, dials or settings necessary, this is an ideal solution to the aggravating problem of tangled cable. The inertia brake design allows the cable to pull easily when you want it and stop when you don’t. With its reinforced side-wall and payout opening design, it offers superior crush resistance and stacking and handling performance. And with its 100% recyclable cardboard design, it is also extremely convenient to dispose of on a job site.
Speed Bag® Packaging Save space, time and money with Speed Bag, and get another innovative packaging solution that works with you to make installations more efficient and
Fewer tangles means:
hassle-free. Speed Bag provides:
• Less labor
• Less packaging for easier storage and transportation • A lighter weight design for reduced freight expenses • Faster and easier pulls – saving time and headaches on the job
• Less wasted cable • Fewer on-the-job headaches • A more productive crew
• Ability to stack multiple wire types in a single bucket – just pull the wire you need • A plastic overwrap that reduces waste and is moisture resistant
SPEED BOX® Packaging Engineered for smoother and faster installations, SPEED BOX is another packaging innovation that helps enable your success every day. All boxes of Honeywell Cable, except REACT packaging, feature SPEED BOX – with two options to deliver cable: • Pull Box • Reel-In-A-Box
Genesis® Series Cable
www.honeywellcable.com | 7 www.h honeyw neywellc ellca llca l able.c blle.c e.c .c com | 7
Works with You Here’s why Honeywell Cable is the right partner for you: We provide customers all over North and South America with industry-leading, high-quality cable, including security, fire, control, thermostat, home theater, multimedia, networking, coax cables, and structured wiring for homes and commercial buildings. Our trusted experience, combined with the quality and reliability of our products, allows customers to meet their existing and emerging connectivity challenges. We offer cables that fit every budget for virtually any installation, including security, HVAC, home automation and control, networking, fire and video applications, and more. And, our pioneering product development only scratches the surface – we know that a trustworthy partnership is a prerequisite to a mutually profitable business relationship. With this in mind, Honeywell Cable stands on the partnership principles of:
Commitment
Innovation
Support
We’re committed to you,
We deliver the newest
We provide support and training
our independent dealers,
innovations, technologies
to keep you ahead
integrators and end-users.
and products.
of the competition.
You are our business, and we are your partner who works with you.
Support from Honeywell Cable — 800-222-0060 Honeywell Cable’s outstanding sales/customer service and technical support is second to none in the low-voltage cable industry. We are equipped with an extensive network of services that include: toll-free technical support and customer service, online technical documents and cross reference. Toll-free Support: Through our toll-free support line, customers get immediate help with troubleshooting from Honeywell Cable’s product experts. Each call is treated with the utmost importance to ensure each customer gets the immediate response they need, when they need it. Customer Service: Honeywell Cable’s customer service and sales representatives stand ready to answer questions. Customers can rest assured that they will get the support they need through every stage of the process. Sales Support: To help customers optimize the many features of their cable and structured solutions, Honeywell Cable provides on-site training for customers.
8 | www.honeywellcable.com
Genesis® Series Cable
readySHIP – Maximize Opportunities to Impress Your Customers Provide certainty in an uncertain business environment by supporting your customers’ ability to forecast inventory and optimize cash flow. Honeywell Cable's readySHIP program will enhance your overall service level and improve your performance in the process. Each readySHIP product will ship right away, allowing you to win more often and keep your business on schedule. Over 100 current products will ship same day (for orders placed prior to 3:00 p.m., after 3:00 p.m. ships next day) – the list is available on our website or by calling customer service (800-222-0060).
Contractor PRO™ – Your Business Counts We’re making it as easy as we can to help you grow your business. As a member of Honeywell’s Contractor PRO program, you’ll earn rebate points on every Honeywell Cable product purchase you make. But that’s only the beginning. With Contractor PRO, you’ll enjoy a variety of ways to add more profit to your business. Member benefits include: • Exclusive technical support (877-880-3383) • Online referrals • FREE sales literature • Personal use product discounts • Regular communications, promotions and account updates For more information, including a complete and current listing of qualifying product part numbers, visit www.contractorpro.com and sign up today!
Wire Merchandising System – Making Life Easier for Contractors As an accessory, it’s important to call attention to cable in order to make it easy for contractors to find what they need right away by merchandising them effectively. These easy-to-install kits don’t require any tools. Simply reserve a small section of your gondola shelves to clear a complete vertical section 36" wide. Our merchandising kits are designed to work with you, and are available with most Honeywell Cable package types – Speed Bags®, Spools, Reels, Buckets, etc. Thermostat wire, control cable and mini-split cable should all be represented near the counter when contractors walk in.
Genesis® Series Cable
www.honeywellcable.com | 9
Customer Testimonials “I can always count on Honeywell Genesis® Series Cable to be competitively priced, have what I need in stock, make it easy to find the part I’m looking for and place an order. I refer to its user-friendly catalog and website all the time.” – Lee Thompson, Beacon Light Supply, Hartford, CT
“Honeywell Genesis® Series Cable consistently delivers dependable products that our customers prefer. The sales, distribution and customer service aspects of the business cater specifically to distributors and consumers like none other. With superior innovation and response to the market, Honeywell Cable is always a premium choice for our business.” – John Schwartzel, Carrier Enterprise Southeast
“Honeywell Cable’s reputation, quality and quick delivery times makes working with them a breeze – it helps me out tremendously. Not to mention, the Contractor PRO™ program makes it convenient for my customers and contractors to continue buying Honeywell products.” – Tommy Hudson, N.B. Handy, Lynchburg, VA
“Honeywell Cable’s REACT™ packaging is a huge asset for installations. It pulls really easily, saving major time and frustration on the job.” – Jason, Security Solutions, NW, Bellingham, WA
“We used to have a lot of issues with damaged cable and interference issues. Ever since switching to Honeywell Cable, however, our installs now go very smoothly and we continue to increase sales.” – Tony, AS Security, Hamilton, ON Canada
“We like buying from Honeywell Cable for several reasons. The pricing is always very competitive, orders are consistently shipped and completed in a timely manner, and between our rep agency and our Honeywell rep, we couldn’t be happier with the service we get.” – Jeff “Tank” Harrington, Ed’s Supply Company, Inc., Nashville, TN
10 | www.honeywellcable.com
Genesis® Series Cable
Customer Service Our Commitment Never Stops To ensure you easily have exactly what you need, when and where you need it, Honeywell Cable’s Inside Sales team is here to help you with all your wire and cable questions and concerns. Support areas include: • Cross referencing competitor parts • Stock inquiries, including lead times and product availability • Technical product information and cable applications • Processing special requests for minimums, colors, details, labeling, etc. • Dealer, representative and distributor information • Fulfilling catalog and sample requests
Our representatives are available between 7:30 a.m. and 5:00 p.m. Central Standard Time. No matter what your question, we welcome the opportunity to speak with you. Call us at: 800-222-0060.
Honeywell Cable Website - www.honeywellcable.com Comprehensive Online Resource In our ongoing efforts to continually provide you with what you need to be successful every day, we have many useful tools that can be accessed through our website such as: • Downloadable product resources, including collateral, videos and complete specs • Company and industry news • Updates on new product innovations • Featured product spotlights • Product selection and competitor cross-reference guides • Distributor and dealer locator information
Genesis® Series Cable
www.honeywellcable.com | 11
Genesis® Series Cable Part Numbers, Packaging and Color Codes All Genesis® Series Cable products come with an eight digit part number: • The first four digits represent the product • The next two digits represent the packaging • The last two digits represent the color code
COLORS Color Code
For Example:
Color
This is a 500' Pull Box of Black
00
Clear
RG6U 60% AL
01
White
5003
= RG6U 60% AL
02
Yellow
55
= 500' Pull Box
03
Orange
08
= Black
04
Red
05
Green
PACKAGING Packaging Code
Put up
01
250' Reel
03
4 x 250' Reel
05
250' SPEED BOX® Pull Box
09
250' Speed Bag®
10
1000' Reel
11
1000' SPEED BOX® Pull Box
18
1000' Speed Bag®
21
1000' SPEED BOX® Reel-In-A-Box
25
2500' Reel
39
5 x 50' Coil
06
Blue
07
Brown
08
Black
09
Gray
10
Purple
11
Pink
12
Natural
13
Beige
40
Violet
41
Fluorescent Pink
45
Neon Green
99
Unjacketed
1G
White w/ Green Stripe
1A
White w/ Orange Stripe White w/Red Stripe
43
100' Reel
1R
46
125' Speed Bag®
4B
Red w/Blue stripe
48
4 x 500' Reel
4G
Red w/Green Stripe
54
500' Reel (1 of 4-pack)
4K
Red w/Black Stripe
55
500' SPEED BOX® Pull Box
4P
Red w/Purple Stripe
58
500' Speed Bag®
4W
Red w/White Stripe
61
500' SPEED BOX® Reel-In-A-Box
4Y
Red w/Yellow Stripe
86
1000' REACT™ Packaging
6R
Blue w/Red Stripe
87
500" REACT™ Packaging
6Y
Blue w/Yellow Stripe
* See Selection Guide on www.honeywellcable.com for complete list of product options.
12 | www.honeywellcable.com
Genesis® Series Cable
Conductor Color Code Charts
CHART 1
CHART 2
MULTI CONDUCTOR CABLES (UP TO 12)
MULTI PAIR CABLES
Conductor
Color
Pair #
1
BLACK
1
BLACK/RED
2
RED
2
BLACK/WHITE
3
WHITE
3
BLACK/GREEN
4
GREEN
4
BLACK/BLUE
5
BROWN
5
BLACK/YELLOW
6
BLUE
6
BLACK/BROWN
7
ORANGE
8
YELLOW
9
PURPLE
10
GRAY
11
PINK
12
Cond 1/Cond 2
TAN EXCEPTION: 1103 and 2103 SOL = BLACK, RED, YELLOW, GREEN
CHART 3 FIRE ALARM CABLES
CHART 4 VOICE AND DATA CABLES
CHART 5 THERMOSTAT WIRE
Conductor
Color
Pair
Color/Stripes
Conductor
1
BLACK
1
BLUE + WHITE/BLUE
1
RED
2
RED
2
ORANGE + WHITE/ORANGE
2
WHITE
3
GREEN
3
GREEN+ WHITE/GREEN
3
GREEN
4
YELLOW
4
BROWN + WHITE/BROWN
4
BLUE
5
BROWN
5
YELLOW
6
BLUE
6
BROWN
7
PURPLE
7
ORANGE
8
PINK
8
BLACK
9
TAN
9
PINK
10
ORANGE
10
GRAY
11
BLACK/WHITE
11
TAN
12
RED/WHITE
12
PURPLE
Genesis® Series Cable
Color
www.honeywellcable.com | 13
NOTES
14 | www.honeywellcable.com
1-800-222-0060
Genesis® Series Cable
SECURITY CABLES Low-voltage wiring you can trust
Ensuring you have the right cable for the right application, our multi-conductor cables are manufactured in a wide variety of gauge sizes, shielding configurations and ratings – including plenum, riser and general purpose – to meet a wide range of security demands. Get cable you can count on for critical applications like alarms, as well as reliable wiring for intercoms, speakers and other low-voltage circuits that are power limited. Features: • Countdown or sequential footage markings • Zone and room markings Article 725: Class 1, Class 2 and Class 3 remote-control, signaling and power limited circuits that are not an integral part of a device or appliance. The scope of this article may include systems such as burglar alarm, access control, sound, nurse call, intercom circuits, some computer network systems, some control circuits for lighting dimmer systems, and some low-voltage control circuits that originate from listed computer equipment. Article 800: Communications circuits, voice and data cables. The scope of this article covers: telephone, telegraph (except radio), voice and data. Class 2 and Class 3 Cables: Type CL2, CL2R, CL2P, CL3 CL3R, CL3P Communication Cables: Type CM, CMR, CMP
Genesis® Series Cable
www.honeywellcable.com | 15
Security Cables - Plenum Rated
Construction Conductors
Bare Copper
Insulation
Plenum PVC
Shielding
N/A
Jacket
Plenum PVC
Ratings/Listings Listings
CMP/CL2P/FT6
Voltage (max.)
300V
Temperature (max.)
75° C max
UNSHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000') at 20°C
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
2
Solid
Unshielded
18
17.6
0.104
7.8
3101
22
2
7 Strand
Unshielded
16.9
26.0
0.116
8.7
3102
22
3
7 Strand
Unshielded
16.9
26.0
0.120
11.6
3127
22
4
Solid
Unshielded
18
17.6
0.120
12.8
3103
22
4
7 Strand
Unshielded
16.9
26.0
0.133
14.4
3104
22
6
7 Strand
Unshielded
16.9
26.0
0.158
20.4
3106
22
8
7 Strand
Unshielded
16.9
26.0
0.171
25.9
3107
22
10
7 Strand
Unshielded
16.9
26.0
0.202
32.9
3108
22
12
7 Strand
Unshielded
16.9
26.0
0.208
38.0
3109
18
2
Solid
Unshielded
6.52
32.1
0.142
15.7
3134
18
2
19 Strand
Unshielded
6.66
32.2
0.148
16.0
3114
18
3
19 Strand
Unshielded
6.66
32.2
0.162
32.0
3126
18
4
19 Strand
Unshielded
6.66
32.2
0.172
28.3
3115
18
6
19 Strand
Unshielded
6.66
32.2
0.206
40.0
3116
18
8
19 Strand
Unshielded
6.66
32.2
0.224
54.4
3117
18
10
19 Strand
Unshielded
6.66
32.2
0.264
69.2
3118
18
12
19 Strand
Unshielded
6.66
32.2
0.275
81.5
3119
16
2
26 Strand
Unshielded
4.19
34.6
0.180
25.3
3121
16
3
26 Strand
Unshielded
4.19
34.6
0.190
35.1
3129
16
4
26 Strand
Unshielded
4.19
34.6
0.210
45.6
3122
14
2
19 Strand
Unshielded
2.62
36.0
0.208
35.4
3123
14
4
19 Strand
Unshielded
2.62
36.0
0.246
67.1
3124
12
2
65 Strand
Unshielded
1.65
36.0
0.252
54.1
3125
16 | www.honeywellcable.com
Genesis® Series Cable
Security Cables - Plenum Rated
Construction Conductors
Bare Copper
Insulation
Plenum PVC
Shielding
100% Aluminum Foil + Drain
Jacket
Plenum PVC
Ratings/Listings Listings
CMP/CL2P/FT6
Voltage (max.)
300V
Temperature (max.)
75° C max
SHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
2
Solid
Shielded
18
29.9
0.108
9.9
3201
22
2
7 Strand
Shielded
16.9
44.0
0.120
11.0
3202
22
3
7 Strand
Shielded
16.9
39.2
0.134
13.9
3227
22
4
Solid
Shielded
18
26.5
0.124
14.9
3203
22
4
7 Strand
Shielded
16.9
39.2
0.137
17.0
3204
22
6
7 Strand
Shielded
16.9
26.0
.0162
23.3
3206
22
8
7 Strand
Shielded
16.9
26.0
0.192
28.9
3207
22
10
7 Strand
Shielded
16.9
26.0
0.216
35.2
3208
22
12
7 Strand
Shielded
16.9
26.0
0.219
41.4
3209
18
2
19 Strand
Shielded
6.66
59.3
0.156
19.3
3214
18
3
19 Strand
Shielded
6.66
50.8
0.166
25.8
3226
18
4
19 Strand
Shielded
6.66
50.8
0.182
32.2
3215
18
5
19 Strand
Shielded
6.66
50.8
0.197
38.3
3276
18
6
19 Strand
Shielded
6.66
32.2
0.216
40.2
3216
18
8
19 Strand
Shielded
6.66
32.2
0.236
58.2
3217
18
10
19 Strand
Shielded
6.66
32.2
0.276
72.3
3218
16
2
26 Strand
Shielded
4.19
65.9
0.180
28.0
3221
16
4
26 Strand
Shielded
4.19
55.6
0.210
49.1
3222
14
2
19 Strand
Shielded
2.62
70.2
0.212
38.8
3223
14
4
19 Strand
Shielded
2.62
58.6
0.238
69.1
3224
Genesis® Series Cable
www.honeywellcable.com | 17
Security Cables - Plenum Rated
Construction Conductors
Bare Copper
Insulation
Plenum PVC
Jacket
Plenum PVC
Ratings/Listings Listings
CMP/CL2P/FT6
Voltage (max.)
300V
Temperature (max.)
75° C max
UNSHIELDED PAIRS
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
3 pairs
7 Strand
Unshielded
16.9
26.0
0.196
22.6
3247
22
4 pairs
7 Strand
Unshielded
16.9
26.0
0.219
28.8
3248
OVERALL SHIELDED PAIRS
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
2 pairs
7 Strand
Shielded
16.9
32.9
0.182
18.8
3281
18 | www.honeywellcable.com
Genesis® Series Cable
Canada Only
Security Cables - CSA Listed
Construction Conductors
Bare Copper
Insulation
Polypropylene
Shielding
N/A
Jacket
PVC
Ratings/Listings Listings
CM/CL2 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
UNSHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
4
Solid
Unshielded
18
18.8
0.120
12.7
1133
18
2
19 Strand
Unshielded
6.66
22.7
0.150
17.6
1170
Genesis® Series Cable
www.honeywellcable.com | 19
Security Cables - Riser Rated
Construction Conductors
Bare Copper
Insulation
Polypropylene
Shielding
N/A
Jacket
PVC
Ratings/Listings Listings
CMR/CL2R/FT4 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
UNSHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
2
Solid
Unshielded
18
18.8
0.106
8.0
2101
22
2
7 Strand
Unshielded
16.9
18.5
0.116
9.2
2102
22
4
Solid
Unshielded
18
18.8
0.120
12.3
2103
22
4
7 Strand
Unshielded
16.9
18.5
0.135
13.4
2104
22
6
7 Strand
Unshielded
16.9
18.5
0.158
18.5
2106
22
12
7 Strand
Unshielded
16.9
18.5
0.208
35.5
2109
20
4
7 Strand
Unshielded
10.5
20.5
0.157
20.9
2113
18
2
19 Strand
Unshielded
6.66
22.7
0.150
16.0
2114
18
4
19 Strand
Unshielded
6.66
22.7
0.174
28.1
2115
18
6
19 Strand
Unshielded
6.66
22.7
0.208
40.0
2116
18
8
19 Strand
Unshielded
6.66
22.7
0.228
53.0
2117
18
10
19 Strand
Unshielded
6.66
22.7
0.268
66.6
2118
18
12
19 Strand
Unshielded
6.66
22.7
0.276
78.8
2119
16
2
26 Strand
Unshielded
4.19
23.2
0.176
23.9
2121
16
4
26 Strand
Unshielded
4.19
23.2
0.205
42.5
2122
14
2
19 Strand
Unshielded
2.62
23.9
0.210
35.1
2123
14
4
19 Strand
Unshielded
2.62
23.9
0.246
66.1
2124
12
2
65 Strand
Unshielded
1.65
24.9
0.264
52.7
2125
20 | www.honeywellcable.com
Genesis® Series Cable
Security Cables - Riser Rated
Construction Conductors
Bare Copper
Insulation
Polypropylene
Shielding
100% Aluminum Foil + Drain
Jacket
PVC
Ratings/Listings Listings
CMR/CL2R/FT4 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
SHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
2
7 Strand
Shielded
16.9
32.0
0.120
9.6
2202
22
4
Solid
Shielded
18
28.7
0.127
13.9
2203
22
4
7 Strand
Shielded
16.9
28.2
0.141
15.6
2204
22
6
7 Strand
Shielded
16.9
18.5
0.162
21.6
2206
22
8
7 Strand
Shielded
16.9
18.5
0.176
26.0
2207
22
10
7 Strand
Shielded
16.9
18.5
0.204
31.2
2208
22
12
7 Strand
Shielded
16.9
18.5
0.210
35.8
2209
18
2
19 Strand
Shielded
6.66
42.9
0.154
18.7
2214
18
4
19 Strand
Shielded
6.66
36.3
0.180
31.4
2215
18
6
19 Strand
Shielded
6.66
22.7
0.214
41.9
2216
18
8
19 Strand
Shielded
6.66
22.7
0.232
54.3
2217
18
10
19 Strand
Shielded
6.66
22.7
0.268
68.3
2218
18
12
19 Strand
Shielded
6.66
22.7
0.281
81.0
2219
16
2
26 Strand
Shielded
4.19
44.3
0.180
26.4
2221
16
4
26 Strand
Shielded
4.19
37.3
0.209
45.6
2222
14
2
19 Strand
Shielded
2.62
46.4
0.216
38.0
2223
14
4
19 Strand
Shielded
2.62
38.8
0.252
68.6
2224
Genesis® Series Cable
www.honeywellcable.com | 21
Security Cables - General Purpose Rated
Construction Conductors
Bare Copper
Insulation
Polypropylene
Shielding
N/A
Jacket
PVC
Ratings/Listings Listings
CM/CL2 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
UNSHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
24
4
Solid
Unshielded
28.6
17.2
0.108
9.2
1140
22
2
Solid
Unshielded
18
18.8
0.104
7.2
1101
22
2
7 Strand
Unshielded
16.9
18.5
0.114
8.8
1102
22
4
Solid
Unshielded
18
18.8
0.120
12.4
1103
22
4
7 Strand
Unshielded
16.9
18.5
0.137
14.0
1104
22
6
Solid
Unshielded
18
18.8
0.140
17.4
1106
22
6
7 Strand
Unshielded
16.9
18.5
0.158
19.4
1107
22
8
Solid
Unshielded
18
18.8
0.152
22.2
1108
22
8
7 Strand
Unshielded
16.9
18.5
0.172
24.1
1109
22
10
7 Strand
Unshielded
16.9
18.5
0.200
27.6
1111 1112
22
12
Solid
Unshielded
18
18.8
0.182
31.5
22
12
7 Strand
Unshielded
16.9
18.5
0.204
34.0
1113
18
2
Solid
Unshielded
6.52
22.8
0.136
14.6
1138
18
2
19 Strand
Unshielded
6.66
22.7
0.148
14.7
1118
18
3
19 Strand
Unshielded
6.66
22.7
0.159
21.3
1130
18
4
19 Strand
Unshielded
6.66
22.7
0.172
26.9
1119
18
6
19 Strand
Unshielded
6.66
22.7
0.206
39.2
1120
18
8
19 Strand
Unshielded
6.66
23.2
0.232
54.0
1121
18
12
19 Strand
Unshielded
6.66
22.7
0.277
78.9
1123
16
2
26 Strand
Unshielded
4.19
23.2
0.172
23.6
1125
16
4
26 Strand
Unshielded
4.19
23.2
0.202
41.7
1126
14
1
Solid
Unshielded
2.57
Null
0.105
16.0
1131
14
2
19 Strand
Unshielded
2.62
23.9
0.210
34.6
1127
12
2
65 Strand
Unshielded
1.65
24.9
0.264
51.0
1129
22 | www.honeywellcable.com
Genesis® Series Cable
Security Cables - General Purpose Rated
Construction Conductors
Bare Copper
Insulation
Polypropylene
Shielding
100% Aluminum Foil + Drain
Jacket
PVC
Ratings/Listings Listings
CM/CL2 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
SHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
2
7 Strand
Shielded
16.9
32.0
0.120
9.7
1202
22
4
7 Strand
Shielded
16.9
28.2
0.139
14.8
1204
22
6
7 Strand
Shielded
16.9
18.5
0.166
21.0
1206
22
8
7 Strand
Shielded
16.9
18.5
0.174
25.8
1207
22
10
7 Strand
Shielded
16.9
18.5
0.204
31.6
1208
22
12
7 Strand
Shielded
16.9
18.5
0.216
35.7
1209
20
2
7 Strand
Shielded
10.5
36.9
0.138
14.8
1212
18
2
19 Strand
Shielded
6.66
42.9
0.154
17.4
1214
18
3
19 Strand
Shielded
6.66
36.3
0.161
24.4
1228
18
4
19 Strand
Shielded
6.66
36.3
0.178
30.1
1215
18
6
19 Strand
Shielded
6.66
22.7
0.210
42.4
1216
18
8
19 Strand
Shielded
6.66
22.7
0.230
55.8
1217
18
10
19 Strand
Shielded
6.66
22.7
0.270
69.6
1218
16
2
26 Strand
Shielded
4.19
44.3
0.178
25.7
1221
16
3
26 Strand
Shielded
4.19
37.3
0.186
35.2
1229
16
4
26 Strand
Shielded
4.19
37.3
0.202
43.8
1222
14
2
19 Strand
Shielded
2.62
46.4
0.214
39.1
1223
Genesis® Series Cable
www.honeywellcable.com | 23
Security Cables - General Purpose Rated
Construction Conductors
Bare Copper
Insulation
Polypropylene
Jacket
PVC
Ratings/Listings Listings
CM/CL2 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
1-PAIR SHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
2 pairs
7 Strand
1 Pair Shielded
16.9
32.0
0.185
16.7
1250
INDIVIDUALLY SHIELDED PAIRS
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
2 pairs
7 Strand
Each Pair Shielded
16.9
32.0
0.165
16.7
1264
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
UNJACKETED
AWG
22
2
7 Strand
Unshielded
16.9
24.1
0.150
9.0
1051
20
2
7 Strand
Unshielded
10.5
27.4
0.170
14.2
1052
14
2
Solid
Unshielded
2.57
27.4
0.228
34.0
1057
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
2
7 Strand
Unshielded
16.9
24.3
.074 x .164
7.5
1002
20
2
7 Strand
Unshielded
10.5
23.7
.083 x .180
13.3
1003
18
2
19 Strand
Unshielded
6.66
29.8
.090 x .190
15.1
1004
ZIP CORD
24 | www.honeywellcable.com
Genesis® Series Cable
ACCESS CONTROL CABLES Bundled technology for quicker installations
Our highly engineered PROFUSION® access control cables use a revolutionary twisting scheme to hold pairs together without binding, preventing deterioration and making for easier installation – just tape the ends and pull. This represents the most cost-effective solution for bundled cable applications. • Countdown or sequential footage markings • Zone and room markings Overall Jacket Access Control Cable provides quick installations and smooth pulls. An overall jacket joins individual lock power, door contact, card reader, and request-to-exit cables into a single convenient cable. With an easier to strip overall jacket, snags are virtually eliminated, creating an overall hassle-free experience. Features: • Easy to strip overall jacket • Snag resistant • Countdown or sequential footage markings
Genesis® Series Cable
www.honeywellcable.com | 25
Access Control - Plenum Rated
PROFUSION® Unjacketed • Reduces cold weather cracking and cable separation • Saves installation time • Components stay unified while pulling; separate easily at access point Overall Jacketed • Easy to strip overall jacket • Snag resistant • Countdown markings on jacket
Ratings/Listings Listings
CMP/CL2P FT6
Voltage (max.)
300V
Temperature (max.)
75° C max
PROFUSION UNJACKETED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
18
4
19 Strand
-
6.52
22.8
22
6
7 Strand
Shielded
16.9
24.3
22
2
7 Strand
-
16.9
24.3
22
4
7 Strand
-
16.9
24.3
18
4
19 Strand
Shielded
6.52
22.8
22
6
7 Strand
Shielded
16.9
24.3
22
2
7 Strand
Shielded
16.9
24.3
22
4
7 Strand
Shielded
16.9
24.3
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
0.395
77.2
3195
0.395
88.5
3295
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
0.350
89.0
3196
0.400
100.8
3296
JACKETED
AWG
18
4
19 Strand
-
6.52
22.8
22
6
7 Strand
Shielded
16.9
24.3
22
2
7 Strand
-
16.9
24.3
22
4
7 Strand
-
16.9
24.3
18
4
19 Strand
Shielded
6.52
22.8
22
6
7 Strand
Shielded
16.9
24.3
22
2
7 Strand
Shielded
16.9
24.3
22
4
7 Strand
Shielded
16.9
24.3
26 | www.honeywellcable.com
Genesis® Series Cable
Access Control - Riser Rated
PROFUSION® Unjacketed • Reduces cold weather cracking and cable separation • Saves installation time • Components stay unified while pulling; separate easily at access point Overall Jacketed • Easy to strip overall jacket • Snag resistant • Countdown markings on jacket
Ratings/Listings Listings
CMR/CL2R FT4 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
PROFUSION UNJACKETED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
18
4
19 Strand
-
6.52
22.8
22
6
7 Strand
Shielded
16.9
24.3
22
2
7 Strand
-
16.9
24.3
22
4
7 Strand
-
16.9
24.3
18
4
19 Strand
Shielded
6.52
22.8
22
6
7 Strand
Shielded
16.9
24.3
22
2
7 Strand
Shielded
16.9
24.3
22
4
7 Strand
Shielded
16.9
24.3
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
0.410
69.5
2195
0.410
80.3
2295
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
0.350
83.1
2196
0.390
96.2
2296
JACKETED
AWG
18
4
19 Strand
-
6.52
22.8
22
6
7 Strand
Shielded
16.9
24.3
22
2
7 Strand
-
16.9
24.3
22
4
7 Strand
-
16.9
24.3
18
4
19 Strand
Shielded
6.52
22.8
22
6
7 Strand
Shielded
16.9
24.3
22
2
7 Strand
Shielded
16.9
24.3
22
4
7 Strand
Shielded
16.9
24.3
Genesis® Series Cable
www.honeywellcable.com | 27
NOTES
28 | www.honeywellcable.com
1-800-222-0060
Genesis® Series Cable
VIDEO SURVEILLANCE CABLES Optimal connectivity Honeywell’s Genesis® Series CCTV* Coaxial cables are engineered to deliver sharp, smooth video signals at an optimal value. Features: • Countdown or sequential footage markings • Room/Zone markings on legend • Color coded boxes • 100% guaranteed
Genesis® Series Cable
www.honeywellcable.com | 29
Conductor Material Bare Copper (BC): • Excellent signal strength for low-frequency applications such as CCTV* • Other materials such as copper clad steel and copper clad aluminum compromise signal integrity and video quality
Shielding Braid Shield: • 95% Bare Copper standard or 95% Copper Clad Aluminum for shorter economical runs • Protects signal transmission from low-frequency interference, EMI* • Ideal for CCTV* or other low-frequency applications *CCTV: Closed Circuit Television *EMI: Electromagnetic Interference (from electric motors, ballasts, and nearby high-voltage currents)
Power Conductors • Bare copper for low voltage drop • Other materials such as copper clad aluminum or copper clad steel can lead to excessive voltage drop, which leads to damage to devices and premature failure
30 | www.honeywellcable.com
Genesis® Series Cable
Video Surveillance Plenum Construction Coax Center Conductor
Bare Copper
Power Conductors
Bare Copper
Coax Shielding
95% Bare Copper Braid
Jacket
Plenum PVC
Ratings/Listings Listings
CMP/CL2P/FT6
Voltage (max.)
300V
Temperature (max.)
75° C max
Riser Construction Coax Center Conductor
Bare Copper
Shielding
95% Bare Copper Braid
Jacket
PVC
Ratings/Listings Listings
CMR/CL2R/FT4 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
PLENUM RATED
Style
Shield
DC Resistance (Ohms/1000')
Velocity of Propagaton (%)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
18
RG6
95% BC
6.52
78%
16.5
0.226
47.0
5352
20
RG59
95% BC
11.1
78%
16.5
0.195
39.0
5351
20
RG59+18/2
95% BC
11.1
78%
16.5
.420 x .200
65.0
5355
Style
Shield
DC Resistance (Ohms/1000')
Velocity of Propagaton (%)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
18
RG6
95%
6.52
78%
17.3
0.275
40.0
5302
20
RG59
95%
11.1
78%
17.3
0.242
32.0
5301
AWG
Product Code
RISER RATED
AWG
Genesis® Series Cable
www.honeywellcable.com | 31
Video Surveillance
General Purpose Construction Center Conductor
Bare Copper
Power Conductors
Bare Copper
Shielding
95% Braid
Jacket
PVC
Ratings/Listings Listings
CM/CL2 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
Water Resistant Construction Center Conductor
Bare Copper
Power Conductors
Bare Copper
Shielding
95% Braid
Jacket
PVC
Ratings/Listings Listings
Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
GENERAL PURPOSE RATED
Style
Shield
DC Resistance (Ohms/1000')
Velocity of Propagaton (%)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
18
RG6
95% BC
6.52
78%
17.3
0.275
42.0
5002
20
RG59
95% BC
11.1
78%
17.3
0.242
36.0
5001
20
RG59
95% CCA
11.1
78%
17.3
0.242
30.0
6501
24
75 Ohm
95% BC
28.6
78%
17.3
0.145
15.0
5020
18
RG6+18/2
95% BC
6.52
78%
17.3
.450 x .275
66.0
5119
20
RG59+18/2
95% BC
11.1
78%
17.3
.420 x .245
60.0
5013
20
RG59+18/2
95% CCA
11.1
78%
17.3
.425 x .240
42.8
6508
Style
Shield
DC Resistance (Ohms/1000')
Velocity of Propagaton (%)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
20
RG59
95% BC
11.1
78%
17.3
0.242
36.0
5103
20
RG59+18/2
95% BC
11.1
78%
17.3
.421 x .245
65.0
5104
AWG
Average Weight (Pounds/1000')
Product Code
WATER RESISTANT RATED
AWG
32 | www.honeywellcable.com
Genesis® Series Cable
NETWORK & IP CABLES Wired for success
Honeywell Genesis® Series Cable satisfies a wide range of power demands with its well-rounded, versatile category cable portfolio – now including Cat 6A and Cat 5e/6 Plus shielded cables. With options for increasing signal speed, improving interruption-free connectivity and strengthening overall data security, there’s a category cable for virtually every application. Features: • Countdown or sequential footage markings • Room numbers on legend • 100% guaranteed Article 800: Communications circuits, voice and data cables. The scope of this article covers: telephone, telegraph (except radio), voice and data Communication Cable: Type CM, CMR, CMP
Genesis® Series Cable
www.honeywellcable.com | 33
Category Cable Quick-Selection Guide
Type
Cat 5e
Cat 6
Cat 6 Plus
Cat 6A
Network Throughput
100 Mb (100m) 1 Gb (30m)
1 Gb (100m) 10 Gb (30m)
1 Gb (100m) 10 Gb (30m)
10 Gb (100m) 40 Gb (30m)
Maximum PoE Power at PD
Up to 12.95 W (802.3af/PoE)
Up to 25.5 W (802.3at/PoE+)
Up to 60 W (802.3bt/ PoE++)*
60 W and beyond* (802.3bt/PoE++)*
Typical Applications
• 802.11 a/b/g hot spot • Regular IP/network camera • IP phone • Access control/ badge reader • Intercom/paging/public address system • Wall clock/message board/
• SISO 802.11n hot spot • HD IP/network camera • Video phone
• MIMO 802.11n hot spot • Outdoor PTZ camera with heater and blower • Thin client • Point of Sales • Video conferencing system • Nurse call system
• 802.11ac hot spot • HDBT hub for audio/ video equipment
Unshielded: 6360, 6361
Unshielded: 5092, 5102
Unshielded: 5193, 5393
lighting control
Product Codes
Unshielded: 6330, 5078, 5088, 5090
Shielded: 5192, 5392 Shielded: 5178, 5388 :OPLSKLK]LYZPVUVќLYZ greater noise and emission WYV[LJ[PVUMVYJVUÄKLU[PHS mission critical applications)
:OPLSKLK]LYZPVUVќLYZ greater noise and emission WYV[LJ[PVUMVYJVUÄKLU[PHS mission critical applications)
*P802.3bt IEEE draft standard
34 | www.honeywellcable.com
Genesis® Series Cable
Network & IP - Cat 6A
Construction
Riser
Conductors
Bare Copper
Plenum
Insulation
PP or PE
Spline
Dielectric Between Pairs
FEP
Jacket
PVC
PVC
Listings
CMR/CL2R/FT4 Sunlight Resistant
CMP/CL2P/FT6
Voltage (max.)
300V
300V
Temperature (max.)
75° C max
75° C max
Ratings/Listings
CAT 6A - PLENUM RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
23
4 pairs
UTP (Unshielded)
22.3
100
14.9
0.320
45.0
5393
CAT 6A - RISER RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
23
4 pairs
UTP (Unshielded)
22.3
100
14.9
0.350
44.0
5193
Genesis® Series Cable
www.honeywellcable.com | 35
Network & IP - Cat 6 Plus
Construction
Riser
Conductors
Bare Copper
Plenum
Insulation
PP or PE
Spline
Dielectric Between Pairs
FEP
Jacket
PVC
PVC
Ratings/Listings Listings
CMR/CL2R/FT4 Sunlight Resistant
CMP/CL2P/FT6
Voltage (max.)
300V
300V
Temperature (max.)
75° C max
75° C max
CAT 6 PLUS - PLENUM RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
23
4 pairs
UTP (Unshielded)
22.3
100
14.9
0.240
28.2
5102
SHIELDED CAT 6 PLUS - PLENUM RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
23
4 pairs
FTP (Shielded)
22.3
100
14.9
0.290
45.0
5392
CAT 6 PLUS - RISER RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
23
4 pairs
UTP (Unshielded)
22.3
100
14.9
0.245
25.0
5092
SHIELDED CAT 6 PLUS - RISER RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
23
4 pairs
FTP (Shielded)
22.3
100
14.9
0.280
35.0
5192
36 | www.honeywellcable.com
Genesis® Series Cable
Network & IP - Cat 6
Construction
Riser
Conductors
Bare Copper
Insulation
PP or PE
Spline
None
Jacket
PVC
Plenum
FEP
PVC
Ratings/Listings Listings
CMR/CL2R/FT4 Sunlight Resistant
CMP/CL2P/FT6
Voltage (max.)
300V
300V
Temperature (max.)
75° C max
75° C max
CAT 6 - PLENUM RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
23
4 pairs
UTP (Unshielded)
22.3
100
14.9
0.205
25.0
6361
CAT 6 - RISER RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
23
4 pairs
UTP (Unshielded)
22.3
100
14.9
0.205
24.0
6360
Genesis® Series Cable
www.honeywellcable.com | 37
Network & IP - Cat 5e
Construction
Riser
Conductors
Bare Copper
Plenum
Insulation
PP or PE
FEP
Jacket
PVC
PVC
Listings
CMR/CL2R/FT4 Sunlight Resistant
CMP/CL2P/FT6
Voltage (max.)
300V
300V
Temperature (max.)
75° C max
75° C max
Ratings/Listings
CAT 5E - PLENUM RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
23
4 pairs
UTP (Unshielded)
28.6
100
14.9
0.200
23.0
5088
SHIELDED CAT 5E - PLENUM RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
24
4 pairs
FTP (Shielded)
28.6
100
14.9
0.240
33.0
5388
CAT 5E - RISER RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
24
4 pairs
UTP (Unshielded)
28.6
100
14.9
0.210
20.0
5078
SHIELDED CAT 5E - RISER RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
24
4 pairs
FTP (Shielded)
28.6
100
14.9
0.210
28.0
5178
38 | www.honeywellcable.com
Genesis® Series Cable
Network & IP - Cat 5e
Construction
Riser
Conductors
Bare Copper
Plenum
Insulation
PP or PE
PP
Jacket
PVC
LLDPE
Listings
CM/CL2, Sunlight Resistant
Direct Burial, Sunlight Resistant
Voltage (max.)
300V
300V
Temperature (max.)
75° C max
75° C max
Ratings/Listings
CAT 5E - GENERAL PURPOSE RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
24
4 pairs
UTP (Unshielded)
28.6
100
14.9
0.200
19.0
6330
CAT 5E - DIRECT BURIAL RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
24
4 pairs
UTP (Unshielded)
28.6
100
14.9
0.225
24.0
5090*
*Pictured above
Genesis® Series Cable
www.honeywellcable.com | 39
Network & IP - Cat 3
Construction
Riser
Conductors
Bare Copper
Plenum
Insulation
PP
PP
Jacket
PVC
N/A
Ratings/Listings Listings
CMR/CL2R Sunlight Resistant
Unlisted
Voltage (max.)
300V
300V
Temperature (max.)
75° C max
75° C max
CAT 3 - RISER RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
24
2 pairs
UTP (Unshielded)
28.6
100
17.1
24
3 pairs
UTP (Unshielded)
28.6
100
17.1
Average Weight (Pounds/1000')
Product Code
0.150
9.9
5031
0.160
14.3
5032
CAT 3 - UNJACKETED CROSS-CONNECT
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
24
1 pair
UTP (Unshielded)
28.6
88.3
17.23
0.064
2.9
1031
2 pairs
UTP (Unshielded)
28.6
88.3
17.23
0.128
5.9
1032
24
40 | www.honeywellcable.com
Genesis® Series Cable
FIRE ALARM CABLES Connectivity you can rely on Designed for optimal safety, Honeywell Fire Alarm Cables are manufactured in a wide variety of gauge sizes, shielding configurations and ratings. We also manufacture fire alarm cables that meet the requirements of New York City Local Law 5 and New York State Toxicity requirements. Features: • Countdown or sequential footage markings • Innovative REACT™ packaging is available • Zone and room markings • UL or CSA listed Fire Cable Types: • General Purpose • Riser • Plenum • Direct Burial • NYC LL5 • CSA Listed FAS105 Article 760: The scope of this article covers the installation of wiring and equipment of fire alarm systems, including all circuits controlled and powered by the fire alarm system. These include fire detection and alarm notification, guard’s tour, sprinkler waterflow and sprinkler supervisory systems. Circuits controlled and powered by the fire alarm system include circuits for the control of building systems’ safety functions, elevator capture, elevator shutdown, door release, smoke doors and damper control, fire doors and damper control and fan shutdown. Applicable only where these circuits are powered by and controlled by the fire alarm system. Fire Power Limited Cable: Type FPL, FPLR, FPLP
Genesis® Series Cable
www.honeywellcable.com | 41
Fire Alarm - Plenum Rated Construction: Construction Conductors
Bare Copper
Insulation
Plenum PVC
Shielding
N/A
Jacket
Plenum PVC
Ratings/Listings Listings
FPLP/CL2P/FT6
Voltage (max.)
300V
Temperature (max.)
75° C max
UNSHIELDED DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
Unshielded
18
17.6
0.143
18.0
4502
Unshielded
6.52
32.1
0.136
15.6
4506
19 Strand
Unshielded
6.66
32.2
0.148
17.0
4524
4
Solid
Unshielded
6.52
32.1
0.157
27.0
4507
18
4
19 Strand
Unshielded
6.66
32.2
0.172
29.2
4525
18
6
Solid
Unshielded
6.52
32.1
0.188
40.6
4508
16
2
Solid
Unshielded
4.1
21.8
0.177
23.1
4511
16
4
Solid
Unshielded
4.1
21.8
0.201
44.2
4512
14
2
Solid
Unshielded
2.57
24.1
0.206
32.7
4513
14
2
19 Strand
Unshielded
2.62
36.0
0.208
36.3
4522
14
4
Solid
Unshielded
2.57
24.1
0.230
65.3
4514
12
2
Solid
Unshielded
1.62
25.9
0.228
54.0
4515
12
2
65 Strand
Unshielded
1.65
36.0
0.265
54.2
4521
AWG
Number of Conductors
Stranding
Shield
22
6
Solid
18
2
Solid
18
2
18
42 | www.honeywellcable.com
Genesis® Series Cable
Fire Alarm - Plenum Rated Construction: Construction Conductors
Bare Copper
Insulation
Plenum PVC
Shielding
100% Aluminum Foil + Drain
Jacket
Plenum PVC
Ratings/Listings Listings
FPLP/CL2P/FT6
Voltage (max.)
300V
Temperature (max.)
75° C max
SHIELDED DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
AWG
Number of Conductors
18
2
Solid
Shielded
6.52
58.9
0.140
18.0
4602
18
2
19 Strand
Shielded
6.66
37.3
0.156
19.8
4614
18
4
Solid
Shielded
6.52
50.5
0.168
29.2
4603
18
6
Solid
Shielded
6.52
32.1
0.192
43.2
4604
16
2
Solid
Shielded
4.1
40.4
0.177
27.4
4606
16
4
Solid
Shielded
4.1
34.5
0.206
46.1
4607
14
2
Solid
Shielded
2.57
47.0
0.211
37.9
4608
14
2
19 Strand
Shielded
2.62
70.2
0.213
42.5
4612
14
4
Solid
Shielded
2.57
39.2
0.247
67.4
4609
12
2
Solid
Shielded
1.62
52.5
0.245
62.1
4610
Genesis® Series Cable
Stranding
Shield
www.honeywellcable.com | 43
Cable
Striped Fire Wire: Simplifying Installations Innovation That Works with You
Easily differentiate between circuits with Honeywell’s striped fire alarm cables. Expedite installations, and eliminate the hassle of marking and tracing cables in a bundle to identify the one you’re looking for. By assigning a different stripe color to each type of circuit on the job site, you will be able to maximize field productivity and minimize time wasted due to confusion. The stripes on these cables are extruded into the cables’ jackets so they won’t rub off like printed ink stripes. Like all Genesis® Series fire alarm cables, Honeywell’s striped fire alarm cables are UL listed and recommended for use in UL Certified Fire Alarm Systems. Honeywell Cable proudly manufactures striped fire alarm cables in Pleasant Prairie, WI, USA!
Here’s a guide to the specific cable products and their stripe colors – all colors come in 1000' reels: DESCRIPTION
18/2 Solid Plenum (FPLP)
16/2 Solid Plenum (FPLP)
14/2 Solid Plenum (FPLP)
44 | www.honeywellcable.com
JACKET COLOR
PART NUMBER
Red with Blue Stripe
4506104B
Red with Black Stripe
4506104K
Red with Purple Stripe
4506104P
Red with White Stripe
4506104W
Red with Yellow Stripe
4506104Y
Red with Blue Stripe
4511104B
Red with Black Stripe
4511104K
Red with Purple Stripe
4511104P
Red with White Stripe
4511104W
Red with Yellow Stripe
4511104Y
Red with Blue Stripe
4513104B
Red with Black Stripe
4513104K
Red with Purple Stripe
4513104P
Red with White Stripe
4513104W
Red with Yellow Stripe
4513104Y Genesis® Series Cable
Fire Alarm - Riser Rated
Construction Conductors
Bare Copper
Insulation
Polypropylene
Ratings/Listings Listings
FPLR/CL2R/FT4 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
ZIP CORD
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
18
2
Solid
Unshielded
6.52
29.9
.088 x .196
16.4
4422
16
2
Solid
Unshielded
4.1
35.4
.094 x .200
23.3
4423
14
2
Solid
Unshielded
2.57
39.5
.108 x .222
33.9
4424
Genesis® Series Cable
www.honeywellcable.com | 45
Fire Alarm - Riser Rated Construction: Construction Conductors
Bare Copper
Insulation
Polypropylene
Shielding
N/A
Jacket
PVC
Ratings/Listings Listings
FPLR/CL2R/FT4 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
UNSHIELDED DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
Unshielded
18
18.8
0.123
12.5
4301
Unshielded
6.52
22.8
0.138
14.7
4306
Solid
Unshielded
6.52
22.8
0.159
26.1
4307
6
Solid
Unshielded
6.52
22.8
0.190
40.0
4308
18
10
Solid
Unshielded
6.52
22.8
0.244
63.2
4310
16
2
Solid
Unshielded
4.1
22.3
0.165
22.5
4311
16
4
Solid
Unshielded
4.1
22.3
0.201
40.2
4312
14
2
Solid
Unshielded
2.57
24.1
0.192
32.1
4313
14
4
Solid
Unshielded
2.57
24.1
0.225
60.7
4314
12
2
Solid
Unshielded
1.62
25.9
0.226
49.8
4315
12
2
65 Strand
Unshielded
1.65
24.9
0.264
53.8
4320
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
AWG
Number of Conductors
Stranding
Shield
22
4
Solid
18
2
Solid
18
4
18
UNSHIELDED MID-CAPACITANCE
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
18
2
Solid
Unshielded
6.52
20.5
0.144
15.4
4431
16
2
Solid
Unshielded
4.1
20.6
0.170
23.4
4432
46 | www.honeywellcable.com
Genesis® Series Cable
Fire Alarm - Riser Rated Construction: Construction Conductors
Bare Copper
Insulation
Polypropylene
Shielding
100% Aluminum Foil + Drain
Jacket
PVC
Ratings/Listings Listings
FPLR/CL2R/FT4 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
SHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
18
2
Solid
Shielded
6.52
42.9
0.142
17.2
4402
18
4
Solid
Shielded
6.52
36.4
0.163
27.8
4403
18
6
Solid
Shielded
6.52
22.8
0.194
41.5
4404
18
8
Solid
Shielded
6.52
22.8
0.210
51.8
4405
16
2
Solid
Shielded
4.1
41.7
0.168
24.7
4406
16
4
Solid
Shielded
4.1
35.5
0.195
41.8
4407
14
2
Solid
Shielded
2.57
46.9
0.205
35.6
4408
14
4
Solid
Shielded
2.57
39.2
0.230
64.1
4409
12
2
Solid
Shielded
1.62
52.5
0.231
56.8
4410
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
SHIELDED MID-CAPACITANCE
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
18
2
Solid
Shielded
6.52
36.8
0.148
18.5
4441
16
2
Solid
Shielded
4.1
33.5
0.187
24.4
4442
Genesis® Series Cable
www.honeywellcable.com | 47
Fire Alarm - General Purpose Rated Construction: Construction Conductors
Bare Copper
Insulation
Polypropylene
Shielding
N/A
Jacket
PVC
Ratings/Listings Listings
FPL/CL2 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
UNSHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
22
4
Solid
Unshielded
18
18.8
0.120
11.3
4101
22
6
Solid
Unshielded
18
18.8
0.140
16.9
4102
18
2
Solid
Unshielded
6.52
22.8
0.136
14.6
4106
18
4
Solid
Unshielded
6.52
22.8
0.165
28.6
4107
18
6
Solid
Unshielded
6.52
22.8
0.188
37.1
4108
18
8
Solid
Unshielded
6.52
22.8
0.210
48.2
4109
18
10
Solid
Unshielded
6.52
22.8
0.246
62.3
4110
16
2
Solid
Unshielded
4.1
22.3
0.172
21.2
4111
16
4
Solid
Unshielded
4.1
22.3
0.201
40.5
4112
14
2
Solid
Unshielded
2.57
24.1
0.192
31.8
4113
14
4
Solid
Unshielded
2.57
24.1
0.225
59.2
4114
12
2
Solid
Unshielded
1.62
25.9
0.226
51.5
4115
48 | www.honeywellcable.com
Genesis® Series Cable
Fire Alarm - General Purpose Rated Construction: Construction Conductors
Bare Copper
Insulation
Polypropylene
Shielding
100% Aluminum Foil + Drain
Jacket
PVC
Ratings/Listings Listings
FPL/Cl2 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
SHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
18
2
Solid
Shielded
6.52
42.9
0.140
16.8
4202
18
4
Solid
Shielded
6.52
36.4
0.161
28.2
4203
18
6
Solid
Shielded
6.52
22.8
0.192
39.4
4204
18
8
Solid
Shielded
6.52
22.8
0.214
49.9
4205
16
2
Solid
Shielded
4.1
41.7
0.177
25.2
4206
14
2
Solid
Shielded
2.57
46.9
0.195
34.4
4208
Genesis® Series Cable
www.honeywellcable.com | 49
Fire Alarm - Metal Clad Construction: Construction Conductors
Bare Copper
Insulation
THHN
Shielding
N/A
Jacket
PVC
Cladding
Aluminum
Marking
Helical red tape
Ratings/Listings Listings
Type MC, FPL
Voltage (max.)
600V (Type MC), 300V (FPL)
Temperature (max.)
90°C Dry / 75°C Wet
UNSHIELDED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000’)
Product Code
18
2 + Ground
Solid
Unshielded
6.52
0.393
66.0
4290
18
4 + Ground
Solid
Unshielded
6.52
0.439
84.4
4291
16
2 + Ground
Solid
Unshielded
4.1
0.416
75.6
4292
16
4 + Ground
Solid
Unshielded
4.1
0.464
108.0
4293
14
2 + Ground
Solid
Unshielded
2.57
0.444
93.6
4294
14
4 + Ground
Solid
Unshielded
2.57
0.504
134.8
4295
12
2 + Ground
Solid
Unshielded
1.62
0.483
121.6
4296
50 | www.honeywellcable.com
Genesis® Series Cable
Fire Alarm - Direct Burial Rated Construction: Construction Conductors
Bare Copper
Insulation
Semi-Rigid PVC
Shielding
N/A
Jacket
PVC
Ratings/Listings Listings
FPL/CL2 Direct Burial Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
UNSHIELDED DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
AWG
Number of Conductors
Stranding
18
2
19 Strand
Unshielded
6.66
14.2
0.260
36.8
4156
18
4
19 Strand
Unshielded
6.66
14.2
0.295
59.0
4157
18
6
19 Strand
Unshielded
6.66
14.2
0.345
75.8
4158
18
8
19 Strand
Unshielded
6.66
14.2
0.375
94.3
4159
16
2
26 Strand
Unshielded
4.19
15.7
0.282
45.4
4151
16
4
26 Strand
Unshielded
4.19
15.7
0.323
70.0
4152
14
2
19 Strand
Unshielded
2.62
17.1
0.310
59.0
4153
14
4
19 Strand
Unshielded
2.62
17.1
0.355
103.1
4154
Genesis® Series Cable
Shield
Part #
www.honeywellcable.com | 51
Fire Alarm - CSA Listed
Canada Only
Construction: Construction Conductors
Bare Copper
Insulation
PVC
Shielding
N/A
Jacket
PVC
Ratings/Listings Listings
Type FAS 105, FT4
Voltage (max.)
300V
Temperature (max.)
75° C max
UNSHIELDED DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
Unshielded
18
24.7
0.182
21.4
4026
Unshielded
6.52
28.1
0.207
25.7
4020
Solid
Unshielded
6.52
28.1
0.218
33.2
4021
4
Solid
Unshielded
6.52
28.1
0.235
42.0
4022
18
5
Solid
Unshielded
6.52
28.1
0.256
50.0
4023
18
6
Solid
Unshielded
6.52
28.1
0.281
59.2
4024
16
2
Solid
Unshielded
4.1
31.0
0.227
33.6
4015
16
3
Solid
Unshielded
4.1
31.0
0.240
44.2
4016
16
4
Solid
Unshielded
4.1
31.0
0.260
55.4
4017
16
5
Solid
Unshielded
4.1
31.0
0.288
68.0
4018
14
2
Solid
Unshielded
2.57
34.1
0.253
45.2
4011
14
4
Solid
Unshielded
2.57
34.1
0.295
78.6
4012
12
2
Solid
Unshielded
1.62
37.4
0.291
64.8
4006
AWG
Number of Conductors
Stranding
Shield
22
4
Solid
18
2
Solid
18
3
18
52 | www.honeywellcable.com
Genesis® Series Cable
Fire Alarm - New York City Local Law 5 Construction: Construction Conductors
Bare Copper
Insulation
Fluoropolymer
Jacket
Fluoropolymer
Ratings/Listings Listings
FPLP/ NYC Certified
Voltage (max.)
300V
Temperature (max.)
150° C max
UNSHIELDED Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
18
4
Solid
Unshielded
6.52
49.0
0.282
46.2
5501
16
2
Solid
Unshielded
4.1
54.3
0.214
33.0
5502
16
4
Solid
Unshielded
4.1
54.3
0.280
58.0
5503
14
2
Solid
Unshielded
2.57
59.7
0.244
45.1
5504
14
4
Solid
Unshielded
2.57
59.7
0.290
79.4
5506
12
2
Solid
Unshielded
1.62
65.3
0.272
63.7
5505
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
18
2
Solid
Shielded
6.52
80.1
0.202
28.0
5550
16
2
Solid
Shielded
4.1
91.7
0.218
35.1
5552
16
4
Solid
Shielded
4.1
81.6
0.250
59.2
5553
14
2
Solid
Shielded
2.57
104.4
0.248
47.3
5554
14
4
Solid
Shielded
2.57
91.5
0.290
81.6
5555
Average Weight (Pounds/1000')
Product Code
SHIELDED
Genesis® Series Cable
www.honeywellcable.com | 53
NOTES
54 | www.honeywellcable.com
1-800-222-0060
Genesis® Series Cable
HVAC & THERMOSTAT CONTROL CABLES Proven precision
HVAC & Thermostat Cables: As the world’s leading thermostat manufacturer, no one knows home comfort systems better than Honeywell. Homeowners seeking a dependable HVAC system will only think about the wiring if it fails. Ensure that it doesn’t by selecting cable from a manufacturer that has the most enhanced and efficient cabling available. The flawless connection of Honeywell’s thermostat and mini split cables throughout the home provide the reliable comfort that homeowners value and you can count on. The new Hybrid thermostat and mini split options, including metal clad, are specifically engineered to tackle the evolving demands and functionality of thermostats and AC units. Plus, they now come in 50' convenience packs for easier handling. Features: • Full range of thermostat (for both older and newer, more energy-efficient models) and commercial control cables • Polypropylene insulation is an exceptional dielectric material, and strips easily and cleanly, saving time • Available for General Purpose (CL2) or Plenum (CL2P) applications • Packaging options: spools, Speed Bags® • 100% guaranteed
Genesis® Series Cable
www.honeywellcable.com | 55
Thermostat Cables Honeywell Thermostat Cables Work with You
Speed Bag® Packaging
Durable Rip Cords
Room and Zone Markings
Save time and hassle by choosing
Strip jackets more easily without
Easily label and identify rooms and
ready-to-dispense, compact, and fully
damaging conductors.
zones using the convenient markings
recyclable packaging.
Hybrid Thermostat Cable: A Perfect Fit When it comes to installing a cable specifically engineered to handle the evolving demands and functionality of thermostats, Hybrid Thermostat Wire delivers exactly what you need:
on the cable jacket.
Hybrid Cables Come in a wide range of conductor constructions and packaging options.
• First cable designed specifically for the power requirements of the circuit – all devices will be properly powered and controls will function as intended • Ideal for both new (energy-efficient) and existing HVAC equipment • Available in 5-, 6-, 8- and 10conductor constructions • Haul around less weight and win more project bids with Hybrid Cable • Comes in a variety of reel and Speed Bag packaging configurations
56 | www.honeywellcable.com
Genesis® Series Cable
Thermostat - Hybrid Construction: Construction Conductors
Bare Copper
Insulation
Polypropylene
Jacket
PVC
Ratings/Listings Listings
CL2, Sunlight Resistant
Voltage (max.)
150V
Temperature (max.)
75° C max
HYBRID THERMOSTAT - GENERAL PURPOSE RATED
Description
Genesis® Series Cable
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
5 Solid Conductors (1x18AWG + 4x20AWG)
0.140
22.3
6713
6 Solid Conductors (1x18AWG + 5x20AWG)
0.168
25.5
6714
8 Solid Conductors (1x18AWG + 7x20AWG)
0.180
32.5
6716
10 Solid Conductors (2x18AWG + 8x20AWG)
0.216
41.5
6718
www.honeywellcable.com | 57
Thermostat - General Purpose Construction: Construction Conductors
Bare Copper
Insulation
Polypropylene
Jacket
PVC
Ratings/Listings Listings
CL2, Sunlight Resistant
Voltage (max.)
150V
Temperature (max.)
75° C max
THERMOSTAT - GENERAL PURPOSE RATED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
20
2
Solid
Unshielded
11.1
20.6
0.118
10.4
4701
20
3
Solid
Unshielded
11.1
20.6
0.124
13.3
4702
20
4
Solid
Unshielded
11.1
20.6
0.136
16.7
4703
20
5
Solid
Unshielded
11.1
20.6
0.148
20.8
4704
20
6
Solid
Unshielded
11.1
20.6
0.161
24.0
4705
20
7
Solid
Unshielded
11.1
20.6
0.161
26.7
4706
20
8
Solid
Unshielded
11.1
20.6
0.174
30.8
4707
18
2
Solid
Unshielded
6.52
22.8
0.136
14.1
4710
18
3
Solid
Unshielded
6.52
22.8
0.144
20.1
4711
18
4
Solid
Unshielded
6.52
22.8
0.157
26.5
4712
18
5
Solid
Unshielded
6.52
22.8
0.172
31.6
4713
18
6
Solid
Unshielded
6.52
22.8
0.188
37.7
4714
18
7
Solid
Unshielded
6.52
22.8
0.188
42.3
4715
18
8
Solid
Unshielded
6.52
22.8
0.204
48.7
4716
18
9
Solid
Unshielded
6.52
22.8
0.220
54.0
4717
18
10
Solid
Unshielded
6.52
22.8
0.240
60.3
4718
18
12
Solid
Unshielded
6.52
22.8
0.248
65.4
4719
58 | www.honeywellcable.com
Genesis® Series Cable
Thermostat - Plenum Construction: Construction Conductors
Bare Copper
Insulation
Plenum PVC
Jacket
Plenum PVC
Ratings/Listings Listings
CL2P/FT6
Voltage (max.)
150V
Temperature (max.)
75° C max
THERMOSTAT - PLENUM RATED
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
18
2
Solid
Unshielded
6.52
22.8
0.136
15.2
4760
18
3
Solid
Unshielded
6.52
22.8
0.144
25.1
4761
18
4
Solid
Unshielded
6.52
22.8
0.157
27.4
4762
18
5
Solid
Unshielded
6.52
22.8
0.172
32.9
4763
18
6
Solid
Unshielded
6.52
22.8
0.188
39.1
4764
18
8
Solid
Unshielded
6.52
22.8
0.204
50.5
4766
18
10
Solid
Unshielded
6.52
22.8
0.240
62.9
4768
Genesis® Series Cable
www.honeywellcable.com | 59
Mini-Split
Metal Clad Mini-Split Cables For systems where indoor unit is powered from the condenser.
Mini-Split Tray Cables For systems where indoor unit is powered from the condenser.
Low-Voltage Mini-Split Cables For systems where the interconnection cable is only for communication.
JACKETED METAL CLAD - TYPE MC
AWG
Number of Conductors
Stranding
Shield
Voltage Rating (max.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
14
4
7 Strand
Unshielded
600V
0.574
153.0
1075
AWG
Number of Conductors
Stranding
Shield
Voltage Rating (max.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
16
4
19 Strand
Unshielded
600V
0.350
75.0
1068
14
4
19 Strand
Unshielded
600V
0.390
100.0
1070
14
7
19 Strand
Unshielded
600V
0.460
155.5
1073
AWG
Number of Conductors
Stranding
Shield
Voltage Rating (max.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
18
4
19 Strand
Shielded
300V
0.178
30.1
1215
16
2
26 Strand
Shielded
300V
0.178
25.7
1221
18
2
19 Strand
Unshielded
300V
0.148
14.7
1118
18
3
19 Strand
Shielded
300V
0.161
24.4
1228
TRAY CABLE - TYPE TC
LOW VOLTAGE
60 | www.honeywellcable.com
Genesis® Series Cable
INTELLIGENT BUILDING SYSTEM (IBS) CABLES Equipped for the most sophisticated applications
As energy and security systems become increasingly intelligent, quality cable becomes an even more important factor. Communication cables used to network controlled circuits must be able to support high-speed data transfer for long distances. Because of this, it’s important to select the right cables that have low capacitance and correctly matched characteristic impedances. Produced in our state-of-the-art facility, Honeywell Cable also offers specialized IBS control cables that meet the requirements for Lutron® systems, BACnet and Echelon® LonWorks.
Fire
HVAC
Detection
Control
& Alarm
Genesis® Series Cable
Intrusion
Digital
Detection
Video
Security
Building
& Access
Automation
Control
Control
www.honeywellcable.com | 61
IBS - BACnet/EIA-485
Construction Conductors
Bare Copper
Insulation
FEP
Shielding
100% Aluminum Foil + Drain
Jacket
Plenum PVC
Ratings/Listings Listings
CMP/CL2P/FT6
Voltage (max.)
300V
Temperature (max.)
75° C max
BACNET/EIA-485 - PLENUM RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
24
1 pair
Shielded
26.7
115
12.5
0.164
21.3
3319
24
1.5 pairs
Shielded
26.7
115
12.5
0.185
15.2
3323
22
1 pair*
Shielded
16.9
100
14.5
0.183
19.6
3251
22
1 pair
Shielded
16.9
115
12.5
0.166
15.5
3320
22
1.5 pairs
Shielded
16.9
115
12.5
0.173
19.3
3324
22
2 pairs
Shielded
16.9
115
12.5
0.192
24.3
3328
18
1 pair
Shielded
6.66
115
12.5
0.256
29.9
3322
* Tinned-copper conductors
62 | www.honeywellcable.com
Genesis® Series Cable
IBS - Echelon® LonWorks® Construction: Construction Conductors
Bare Copper
Insulation
FEP
Shielding
100% Aluminum Foil + Drain
Jacket
Plenum PVC
Ratings/Listings Listings
CMP/CL2P/FT6
Voltage (max.)
300V
Temperature (max.)
75° C max
ECHELON LONWORKS - PLENUM RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code 3252
22
1 pair
Unshielded
16.9
100
15.3
0.120
10.0
22
2 pairs
Unshielded
16.9
100
15.3
0.196
18.5
3253
22
1 pair
Shielded
16.9
100
14.5
0.192
18.5
3254
22
2 pairs
Shielded
16.9
125
11.7
0.265
29.2
3255
MISCELLANEOUS - PLENUM RATED
AWG
Number of Pairs
Type
DC Resistance (Ohms/1000')
Impedance (Ohms)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
18
1
Shielded
6.66
58.1
26.21
0.190
24.6
4652
Genesis® Series Cable
www.honeywellcable.com | 63
IBS - Lutron®
Construction Conductors
Bare Copper
Insulation
Polypropylene
Shielding
100% Aluminum Foil + Drain
Jacket
PVC
Ratings/Listings Listings
CM/CL2 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
LUTRON - GENERAL PURPOSE
Style
Construction
Shield
Jacket Color
Product Code
Keypad Data/ GRAFIKEye® 3000
22/1pr Low Cap Data 18/2 Power
Al/Mylar TC Drain
Blue/Yellow Stripe
1244
GRAFIK Eye 4000/6000
22/1pr Low Cap Data 12/2 Power 18/1 Ground
Al/Mylar TC Drain
Blue
1260
Sivoia® Shades
18/4 BC 16/2 BC 18/1 BC
Al/Mylar TC Drain None None
Blue/Red Stripe
1287
64 | www.honeywellcable.com
Genesis® Series Cable
IRRIGATION/TRACER & LIGHTING CABLES Better protection, better performance
Single Conductor Sprinkler and Tracer Wire: (UL Listed Sprinkler and Tracer Wire 600V) Designed for underground applications where harsh conditions may be encountered, tracer wire is ideal for buried applications as a way of easily identifying pipes and cables with a specific color code. Typically, tracer wire is color coded as follows: • Yellow - Gas Pipes • Blue - Water Pipes • Orange - Fiber Optic Cables • Green - Sewage Lines Another primary use for this cable is to connect the remote control valves of an irrigation system in a golf course sprinkler system. Landscape Lighting Cable: (UL Listed Underground Low Energy Circuit Cable 150V) Approved for direct burial and sunlight resistant, these cables are perfect for low-voltage direct burial lighting applications.
Genesis® Series Cable
www.honeywellcable.com | 65
Underground Lighting
Construction Conductors
Bare Copper
Insulation/Jacket
PVC
Ratings/Listings Listings
ULECC, Sunlight Resistant, Direct Burial
Voltage (max.)
150V
Temperature (max.)
75° C max
DIRECT BURIAL RATED
AWG
Number of Conductors
Stranding
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
14
2
41 Strand
.165 x .365
44.1
1021
12
2
65 Strand
.190 x .390
68.3
1019
10
2
104 Strand
.214 x .422
99.0
1018
8
2
168 Strand
.287 x .595
162.3
1017
66 | www.honeywellcable.com
Genesis® Series Cable
Irrigation/Tracer
Construction Conductors
Bare Copper
Insulation
Polyethylene
Ratings/Listings Listings
UL Tracer, Sunlight Resistant, Direct Burial
Voltage (max.)
600V
Temperature (max.)
75° C max
DIRECT BURIAL RATED
AWG
Number of Conductors
Stranding
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
18
1
Solid
0.133
10.0
1301
14
1
Solid
0.157
18.7
1303
12
1
Solid
0.174
27.4
1304
Genesis® Series Cable
www.honeywellcable.com | 67
NOTES
68 | www.honeywellcable.com
1-800-222-0060
Genesis® Series Cable
AUDIO/VIDEO CABLES Better cables, bolder sound
Our wide range of application-specific cable options assure the best performance in high-end home theater installations, incorporating HDTV and digital video, audio, stereo, professional audio systems and home theater systems. AUDACIOUS® Premium Audio Cable Oxygen Free Copper High Strand Count: • WaveFLEX jacket (easy strip) • Oxygen-free copper (pure transmission) • High strand count (flexibility and more surface area) • Legend markings (channel, rooms and zones) • Countdown footage markings Home Theater Sound: • Twisted Bare Copper Conductors • Polypropylene Insulation • Countdown Footage Markings Direct Burial Audio Cable: • Oxygen-free copper (pure transmission) • High strand count (flexibility and more surface area) • Burial Applications CATV Video Cables: • Quad-shield or dual-shield construction
Genesis® Series Cable
www.honeywellcable.com | 69
Honeywell’s line of Audacious Sound Cable® continues to make noise – rounding out with a new 12-gauge option for longer runs. Get more sound with Audacious®, Honeywell’s best and highest quality line of audio cable. Using an oxygen-free copper conductor for optimal conductivity and a high strand count for maximum
Hear the Difference
purity, Audacious offers enhanced signal integrity and minimal distortion. Housed in our patent-pending WaveFlex™ ridged jacketing, cable is now easier than ever to strip, making for quicker installation and termination. Able to withstand the rigors of challenging applications, it delivers robust performance, time and time again. See for yourself – it’s like music to your ears. Insist on quality and innovation you can trust. Insist on Honeywell Audacious Sound Cable.
For more information visit www.honeywellcable.com, or © 2016 Honeywell International. All rights reserved.
70 | www.honeywellcable.com
contact your local ADI Representative.
Genesis® Series Cable
Audio/Video - Audacious® Premium Audio
Construction Conductors
Oxygen Free Bare Copper
Insulation
PVC
Shielding
N/A
Jacket
WaveFLEX® PVC
Ratings/Listings Listings
CMR/CL3R/FT4 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
AUDACIOUS PREMIUM AUDIO
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
16
2
65 Strand
Unshielded
4.19
39.8
0.250
36.4
5473
16
4
65 Strand
Unshielded
4.19
39.8
0.294
57.4
5474
14
2
105 Strand
Unshielded
2.62
44.9
0.306
49.3
5475
14
4
105 Strand
Unshielded
2.62
44.9
0.347
84.1
5476
12
2
105 Strand
Unshielded
1.65
49.3
0.340
34.0
5477
Genesis® Series Cable
www.honeywellcable.com | 71
Audio/Video - Audacious® Premium Audio
Construction Conductors
Oxygen Free Bare Copper
Insulation
Semi-Rigid PVC
Shielding
N/A
Jacket
PVC
Ratings/Listings Listings
CM/CL3 Direct Burial Sunlight Sun Res Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
AUDACIOUS PREMIUM DIRECT BURIAL AUDIO
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
16
2
26 Strand
Unshielded
4.19
35.2
0.274
45.3
5283
16
4
26 Strand
Unshielded
4.19
35.2
0.350
76.3
5284
14
2
41 Strand
Unshielded
2.62
40.0
0.320
61.1
5285
14
4
41 Strand
Unshielded
2.62
40.0
0.365
104.5
5286
72 | www.honeywellcable.com
Genesis® Series Cable
Audio/Video - Home Theater Sound
Construction Conductors
Bare Copper
Insulation
Polypropylene
Shielding
N/A
Jacket
PVC
Ratings/Listings Listings
CM/CL3 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
HOME THEATER SOUND
AWG
Number of Conductors
Stranding
Shield
DC Resistance (Ohms/1000')
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
16
2
26 Strand
Unshielded
4.19
22.5
0.180
22.7
5250
16
4
26 Strand
Unshielded
4.19
22.5
0.210
42.7
5251
14
2
41 Strand
Unshielded
2.62
24.6
0.224
35.6
5252
14
4
41 Strand
Unshielded
2.62
24.6
0.260
65.7
5253
12
2
65 Strand
Unshielded
1.65
26.4
0.264
52.7
5254
12
4
65 Strand
Unshielded
1.65
26.4
0.312
100.0
5255
Genesis® Series Cable
www.honeywellcable.com | 73
Audio/Video - Video Plenum Construction Coax Center Conductor
Copper Clad Steel or Bare Copper
Jacket
Plenum PVC
Ratings/Listings Listings
CATVP/CL2P
Voltage (max.)
300V
Temperature (max.)
75° C max
Riser Construction Coax Center Conductor
Copper Clad Steel or Bare Copper
Jacket
PVC
Ratings/Listings Listings
CATVR/CMR/CL2R/FT4 Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
CATV COAX - PLENUM RATED DC Resistance (Ohms/1000')
Velocity of Propagaton (%)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
AWG
Style
Shield
18 CCS
RG6
Quad 60/40%
6.52
78%
16.5
0.264
41.0
5356
18 CCS
RG6
Dual 60%
6.52
78%
16.5
0.236
36.0
5353
DC Resistance (Ohms/1000')
Velocity of Propagaton (%)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
CATV COAX - RISER RATED
AWG
Style
Shield
18 CCS
RG6
Quad 60/40%
6.52
78%
16.5
0.298
30.0
5307
18 CCS
RG6
Dual 60%
6.52
78%
16.5
0.275
30.0
5303
18 BC
RG6
Dual 60%
6.52
78%
15.5
0.275
30.0
5304
74 | www.honeywellcable.com
Genesis® Series Cable
Audio/Video - Video General Purpose Construction Coax Center Conductor
Copper Clad Steel or Bare Copper
Jacket
PVC
Ratings/Listings Listings
CATV/CL2P Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
Water Resistant Construction Coax Center Conductor
Copper Clad Steel or Bare Copper
Jacket
Polyethylene
Ratings/Listings Listings
Sunlight Resistant
Voltage (max.)
300V
Temperature (max.)
75° C max
CATV COAX - GENERAL PURPOSE RATED
Shield
DC Resistance (Ohms/1000')
Velocity of Propagaton (%)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
RG11
Dual 60%
2.57
78%
16.5
0.400
62.0
5018
RG6
Quad 60/40%
6.52
78%
16.5
0.295
33.0
5007
2 x RG6
Quad 60/40%
6.52
78%
16.5
.298 x .605
70.0
5008
AWG
Style
14 CCS 18 CCS 18 CCS 18 BC
RG6
Quad 60/40%
6.52
78%
16.5
0.298
35.0
5027
18 CCS
RG6
Dual 60%
6.52
78%
16.5
0.275
29.0
5003
20 CCS
RG59
Dual 40%
11.1
78%
17.3
0.244
25.0
5006
DC Resistance (Ohms/1000')
Velocity of Propagaton (%)
Nominal Capacitance (pF/ft.)
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
CATV COAX - WATER RESISTANT RATED
AWG
Style
Shield
18 CCS
RG6
Quad 60/40%
6.52
78%
16.5
0.298
32.0
5106
18 CCS
RG6
Dual 60%
6.52
78%
16.5
0.275
32.0
5105
Genesis® Series Cable
www.honeywellcable.com | 75
NOTES
76 | www.honeywellcable.com
1-800-222-0060
Genesis® Series Cable
MULTIMEDIA CABLES Multipurpose, saving time and money
Honeywell Cable offers multimedia cables to support voice, video and data in a single cable. Multimedia cables are composite constructions designed to minimize the number of cable pulls, reduce installation cost and shorten the time required for the pre-wiring of residential systems. Features: • Multiple constructions available • Cables are performance tested after bundling to assure quality • Reduces labor time and installation cost • UL/ETL listed and verified • 100% guaranteed • Zone and room markings available on jacketed multimedia cables Article 725: Class 1, Class 2 and Class 3 remote-control, signaling and power limited circuits that are not an integral part of a device or appliance. The scope of this article may include systems such as burglar alarm, access control, sound, nurse call, intercom circuits, some computer network systems, some control circuits for lighting dimmer systems, and some low-voltage control circuits that originate from listed computer equipment. General Purpose Cable: Type CM, CL3
Genesis® Series Cable
www.honeywellcable.com | 77
Multimedia Honeywell Multimedia Cable Specifications: • General Purpose Rated • CM/CL3, Sunlight Resistant Listed • Rated to 75° C max • Cat cables sweep tested to 350 MHz (Cat 5e guaranteed up to 100MHz and Cat 6 Plus guaranteed up to 250MHz), exceeding the TIA/EIA-568-C.2 standard, guaranteeing the non-degraded capability of network throughput 100Mbps (Cat 5e) /1Gbps (Cat 6 Plus) at 100m – ideal for all residential multimedia, voice, video, and data applications • Coax component: braided and foiled shielding layer, sweep tested to 3GHz, ideal for HDTV, DBS, CATV, SVHS, CCTV and cable modem applications
JACKETED MULTIMEDIA
Description
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
(2) RG6 CCS Quad-Shield Coax + (2) 24/4 pair Cat 5e
0.670
115.2
5050
(2) RG6 CCS Quad-Shield Coax + (2) 23/4 pair Cat 6 Plus
0.650
154.0
5065
Description
Nominal Outer Diameter (inches)
Average Weight (Pounds/1000')
Product Code
RG6 CCS Quad-Shield Coax + 24/4 pair Cat 5e
.298 x .523
40.8
5066
RG6 CCS Dual-Shield 60% Coax + 24/4 pair Cat 5e
.275 x .520
39.9
5067
DUAL ZIP
78 | www.honeywellcable.com
Genesis® Series Cable
TECHNICAL DATA, TOOLS & RESOURCES The NEC is a highly regarded handbook resource and considered the most comprehensive document on electrical safety. The NEC was developed by a large cross-section of representatives from the electrical industry (electricians, engineers, code enforcers, researchers, testers, insurers, etc.) The NEC explains current code requirements and discusses pertinent code changes. Specific technical language is contained in the handbook with complete information on: • Code Requirements and Application • Code Intent • Code Restrictions • Code Interpretations In addition, historical trends are examined, and tables and illustrations are provided. The NEC is divided into sections containing articles on specific electrical subject areas. Community codes for installations are usually based on information or requirements in the NEC. For convenience, Honeywell’s Genesis® Series Cable catalog has identified pertinent NEC articles and scope of article for each cable group as well as provided useful information to help with ordering appropriate cable.
Genesis® Series Cable
www.honeywellcable.com | 79
Cable Substitution Hierarchy (Based on National Electric Code)
Article 820
Article 800
Article 760
Article 725
Plenum
CATVP
CMP
CL3P
CL2P
CL3R
CL2R
CL3
CL2
CL3X
CL2X
FPLP
Riser
CATVR
CMR FPLR
General Purpose
CATV
CM FPL
Dwellings
CATVX
CMX
Article 820: Community Antenna Television and Radio Distribution Systems Article 800: Communication Circuits Article 760: Fire Alarm Systems Article 725: Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits
80 | www.honeywellcable.com
Genesis® Series Cable
ANSI/TIA/EIA-568C.2: Commercial Building Telecommunications Cabling Standard
The following tables list attenuation and near-end crosstalk (NEXT) specifications from ANSI/TIA/EIA-568C.2 for Category 3, Category 5 and 6 unshielded twisted pair (UTP) cables. TABLE 1: HORIZONTAL UTP CABLE ATTENUATION DB/100 m (DB/1000 ft.) Frequency (MHz)
Category 3 (dB)
Category 5e (dB)
Category 6 (dB)
0.772
2.2
n/s
n/s
Category 6A (dB) n/s
1.00
2.6
2.0
2.0
2.1
4.00
5.6
4.1
3.8
3.8
8.00
8.5
5.8
5.3
5.3
10.00
9.7
6.5
6.0
5.9
16.00
13.1
8.2
7.6
7.5
20.00
-
9.3
8.5
8.4
25.00
-
10.4
9.5
9.4
31.25
-
11.7
10.7
10.5
62.50
-
17.0
15.4
15.0
100.00
-
22.0
19.8
19.1
200.00
-
-
29.0
27.6
250.00
-
-
32.8
31.1
300.00
-
-
-
34.3
400.00
-
-
-
40.1
500.00
-
-
-
45.3
Category 6A (dB)
TABLE 2: HORIZONTAL UTP CABLE ATTENUATION DB/100 m (DB/1000 ft.) Frequency (MHz)
Category 3 (dB)
Category 5e (dB)
Category 6 (dB)
0.772
43.0
n/s
n/s
n/s
1.00
41.3
65.3
74.3
74.3
4.00
32.3
56.3
65.3
65.3
8.00
27.8
51.8
60.8
60.8
10.00
26.3
50.3
59.3
59.3
16.00
23.2
47.2
56.2
56.2
20.00
-
45.8
54.8
54.8
25.00
-
44.3
53.3
53.3
31.25
-
42.9
51.9
51.9
62.50
-
38.4
47.4
47.4
100.00
-
35.3
44.3
44.3
200.00
-
-
39.8
39.8
250.00
-
-
38.3
38.3
300.00
-
-
-
37.1
400.00
-
-
-
35.3
500.00
-
-
-
33.8
Genesis® Series Cable
www.honeywellcable.com | 81
Voltage Drop and Recommended Footage Chart
Approximate Voltage Drop at 68° F 14
26AWG
24AWG 22AWG
Voltage Drop/Amps
12 10
20AWG
8 6
18AWG 16AWG
4 2 300
0 0
50
100
150
200
350
250
Feet
Note: The chart above shows the approximate values for the AC resistive component of the circuit impedance. Example: What is the voltage drop for an 18 AWG 2/C carrying 3 amps over a distance of 100 feet? Voltage-drop
= voltage-drop/amp x amp = 1.2 x 3 = 3.6 Volts
Recommended Footage/AWG Audio Cable MAXIMUM CABLE LENGTH (FT.) Acceptable Loss (%)
4 Ohm Speaker
8 Ohm Speaker
10%
20%
50%
10%
20%
50%
12 AWG
250
500
50
500
1000
2500
14 AWG
150
300
750
300
600
1500
16 AWG
95
190
475
190
380
950
82 | www.honeywellcable.com
Genesis® Series Cable
General Information
CCTV TRANSMISSION DISTANCES Style
Typical Run Length
RG6/U
Up to 1500 ft.
RG59/U BC Braid
Up to 750 ft.
RG59/U CCA Braid
Up to 600 ft.
75 Ohm Mini Coax
Up to 375 ft.
PULLING TENSIONS Under the stress of approximately 15,000 pounds per square inch, annealed copper will begin to permanently stretch. The table below lists the absolute maximum recommended pulling tensions for conductor sizes. For multiple conductor cable, multiply the appropriate value by the total number of conductors. These pulling tensions must be equally distributed among the conductors. THESE LIMITS MUST NEVER BE EXCEEDED EVEN MOMENTARILY. DO NOT JERK THE CABLE. The electronic characteristics of a cable may change due to excessive tension and crushing.
PULLING TENSIONS Recommended Pulling Tension (75% of Max.) (lbs.)
Gauge (AWG)
Max. Pulling Tension (lbs.)
24
4
3.0
22
7
5.25
Genesis® Series Cable
20
12
9.0
18
19
14.25
16
30
22.5
14
48
36.0
12
77
57.75
www.honeywellcable.com | 83
Conduit Capacity Chart
Conduit Trade Size (in.)
0.5
0.75
1
1.25
1.5
2
2.5
3
3.5
4
I.D. (IN.)
0.622
0.824
1.049
1.38
1.61
2.067
2.731
3.356
3.834
4.334
Cable O.D. (in.)
Cable Area (in.)*
0.100
0.008
15
27
44
76
104
171
298
450
588
751
0.125
0.012
10
17
28
49
66
109
191
288
376
481
Numbers Listed Below are Based on 40% Fill Rate for Three or More Cables
0.150
0.018
7
12
20
34
46
76
133
200
261
334
0.175
0.024
5
9
14
25
34
56
97
147
192
245
0.200
0.031
4
7
11
19
26
43
75
113
147
188
0.225
0.040
3
5
9
15
20
34
59
89
116
148 120
0.250
0.049
2
4
7
12
17
27
48
72
94
0.275
0.059
2
4
6
10
14
23
39
60
78
99
0.300
0.071
2
3
5
8
12
19
33
50
65
83
0.325
0.083
1
3
4
7
10
16
28
43
56
71
0.350
0.096
1
2
4
6
8
14
24
37
48
61
0.375
0.110
1
2
3
5
7
12
21
32
42
53
0.400
0.126
1
2
3
5
6
11
19
28
37
47
0.425
0.142
1
2
2
4
6
9
17
25
33
42
0.450
0.159
1
1
2
4
5
8
15
22
29
37
0.475
0.177
1
1
2
3
5
8
13
20
26
33
0.500
0.196
1
1
2
3
4
7
12
18
24
30
0.525
0.216
1
1
2
3
4
6
11
16
21
27
0.550
0.237
1
1
1
3
3
6
10
15
19
25
0.575
0.260
0
1
1
2
3
5
9
14
18
23
0.600
0.283
0
1
1
2
3
5
8
13
16
21
0.625
0.307
0
1
1
2
3
4
8
12
15
19
0.650
0.332
0
1
1
2
2
4
7
11
14
18
0.675
0.358
0
1
1
2
2
4
7
10
13
16
0.700
0.385
0
1
1
2
2
3
6
9
12
15
0.725
0.413
0
1
1
1
2
3
6
9
11
14
0.750
0.442
0
0
1
1
2
3
5
8
10
13
0.775
0.471
0
0
1
1
2
3
5
7
10
13
0.800
0.502
0
0
1
1
2
3
5
7
9
12
0.825
0.534
0
0
1
1
2
3
4
7
9
11
0.850
0.567
0
0
1
1
1
2
4
6
8
10 10
0.875
0.601
0
0
1
1
1
2
4
6
8
0.900
0.636
0
0
1
1
1
2
4
6
7
9
0.925
0.672
0
0
1
1
1
2
3
5
7
9
0.950
0.708
0
0
0
1
1
2
3
5
7
8
0.975
0.746
0
0
0
1
1
2
3
5
6
8
1.000
0.785
0
0
0
1
1
2
3
5
6
8
1.025
0.825
0
0
0
1
1
2
3
4
6
7
1.050
0.865
0
0
0
1
1
2
3
4
5
7
1.075
0.907
0
0
0
1
1
1
3
4
5
7
* Use as a guide when attempting to estimate conduit fill. Consult the NEC for specific information regarding conduit fill.
84 | www.honeywellcable.com
Genesis® Series Cable
Glossary of Abbreviations
AI
Aluminum
BC
Bare Copper
CATV
Community Antenna Television
CCA
Copper Covered Aluminum/Copper Clad Aluminum
CCS
Copper Covered Steel/Copper Clad Steel
CCTV
Closed Circuit Television
EMI
Eletromagnetic Interference
FEP
Fluorinated Ethylene Propylene
HDTV
High Definition Television
LLDPE
Linear Low-Density Polyethylene
LSPVC
Low-Smoke Polyvinyl Chloride
MATV
Master Antenna Television
OFBC
Oxygen-Free Bare Copper
PE
Polyethylene
PP
Polypropylene
PVC
Polyvinyl Chloride
RFI
Radio Frequency Interference
SRPVC
Semi-Rigid Polyvinyl Chloride
TC
Tinned Copper
TPE
Thermoplastic Elastomer
UTP
Unshielded Twisted Pair
Genesis® Series Cable
www.honeywellcable.com | 85
NOTES
86 | www.honeywellcable.com
1-800-222-0060
Genesis® Series Cable
INDEX
Index by Honeywell Genesis® Cable Part Number 1002.............................................24 1003.............................................24 1004.............................................24 1017.............................................66 1018.............................................66 1019.............................................66 1021.............................................66 1031.............................................40 1032.............................................40 1051.............................................24 1052.............................................24 1057.............................................24 1068.............................................60 1070.............................................60 1073.............................................60 1075.............................................60 1101.............................................22 1102.............................................22 1103.............................................22 1104.............................................22 1106.............................................22 1107.............................................22 1108.............................................22 1109.............................................22 1111.............................................22 1112.............................................22 1113.............................................22 1118.....................................22, 60 1119.............................................22 1120.............................................22 1121.............................................22 1123.............................................22 1125.............................................22 1126.............................................22 1127.............................................22 1129.............................................22 1130.............................................22 1131.............................................22 1133.............................................19 1138.............................................22 1140.............................................22 1170.............................................19 1202.............................................23 1204.............................................23 1206.............................................23 1207.............................................23 1208.............................................23 1209.............................................23 1212.............................................23 1214.............................................23 1215.....................................23, 60 1216.............................................23 1217.............................................23 1218.............................................23 1221.....................................23, 60 1222.............................................23 Genesis® Series Cable
1223.............................................23 1228.....................................23, 60 1229.............................................23 1244.............................................64 1250.............................................24 1260.............................................64 1264.............................................24 1287.............................................64 1301.............................................67 1303.............................................67 1304.............................................67 2101.............................................20 2102.............................................20 2103.............................................20 2104.............................................20 2106.............................................20 2109.............................................20 2113.............................................20 2114.............................................20 2115.............................................20 2116.............................................20 2117.............................................20 2118.............................................20 2119.............................................20 2121.............................................20 2122.............................................20 2123.............................................20 2124.............................................20 2125.............................................20 2195.............................................27 2196.............................................27 2202.............................................21 2203.............................................21 2204.............................................21 2206.............................................21 2207.............................................21 2208.............................................21 2209.............................................21 2214.............................................21 2215.............................................21 2216.............................................21 2217.............................................21 2218.............................................21 2219.............................................21 2221.............................................21 2222.............................................21 2223.............................................21 2224.............................................21 2295.............................................27 2296.............................................27 3101.............................................16 3102.............................................16 3103.............................................16 3104.............................................16 3106.............................................16 3107.............................................16
3108.............................................16 3109.............................................16 3114.............................................16 3115.............................................16 3116.............................................16 3117.............................................16 3118.............................................16 3119.............................................16 3121.............................................16 3122.............................................16 3123.............................................16 3124.............................................16 3125.............................................16 3126.............................................16 3127.............................................16 3129.............................................16 3134.............................................16 3195.............................................26 3196.............................................26 3201.............................................17 3202.............................................17 3203.............................................17 3204.............................................17 3206.............................................17 3207.............................................17 3208.............................................17 3209.............................................17 3214.............................................17 3215.............................................17 3216.............................................17 3217.............................................17 3218.............................................17 3221.............................................17 3222.............................................17 3223.............................................17 3224.............................................17 3226.............................................17 3227.............................................17 3247.............................................18 3248.............................................18 3251.............................................62 3252.............................................63 3253.............................................63 3254.............................................63 3255.............................................63 3276.............................................17 3281.............................................18 3295.............................................26 3296.............................................26 3319.............................................62 3320.............................................62 3322.............................................62 3323.............................................62 3324.............................................62 3328.............................................62 4006.............................................52
1002-4320
4011.............................................52 4012.............................................52 4015.............................................52 4016.............................................52 4017.............................................52 4018.............................................52 4020.............................................52 4021.............................................52 4022.............................................52 4023.............................................52 4024.............................................52 4026.............................................52 4101.............................................48 4102.............................................48 4106.............................................48 4107.............................................48 4108.............................................48 4109.............................................48 4110.............................................48 4111.............................................48 4112.............................................48 4113.............................................48 4114.............................................48 4115.............................................48 4151.............................................51 4152.............................................51 4153.............................................51 4154.............................................51 4156.............................................51 4157.............................................51 4158.............................................51 4159.............................................51 4202.............................................49 4203.............................................49 4204.............................................49 4205.............................................49 4206.............................................49 4208.............................................49 4290.............................................50 4291.............................................50 4292.............................................50 4293.............................................50 4294.............................................50 4295.............................................50 4296.............................................50 4301.............................................46 4306.............................................46 4307.............................................46 4308.............................................46 4310.............................................46 4311.............................................46 4312.............................................46 4313.............................................46 4314.............................................46 4315.............................................46 4320.............................................46 www.honeywellcable.com | 87
INDEX
Index by Honeywell Genesis® Cable Part Number 4402.............................................47 4403.............................................47 4404.............................................47 4405.............................................47 4406.............................................47 4407.............................................47 4408.............................................47 4409.............................................47 4410.............................................47 4422.............................................45 4423.............................................45 4424.............................................45 4431.............................................46 4432.............................................46 4441.............................................47 4442.............................................47 4502.............................................42 4506.............................................42 4507.............................................42 4508.............................................42 4511.............................................42 4512.............................................42 4513.............................................42 4514.............................................42 4515.............................................42 4521.............................................42 4522.............................................42 4524.............................................42 4525.............................................42 4602.............................................43 4603.............................................43 4604.............................................43 4606.............................................43 4607.............................................43 4608.............................................43 4609.............................................43 4610.............................................43 4612.............................................43 4614.............................................43 4652.............................................63 4701.............................................58 4702.............................................58 4703.............................................58 4704.............................................58 4705.............................................58 4706.............................................58 4707.............................................58 4710.............................................58 4711.............................................58 4712.............................................58 4713.............................................58 4714.............................................58 4715.............................................58 4716.............................................58 4717.............................................58 4718.............................................58 88 | www.honeywellcable.com
4719.............................................58 4760.............................................59 4761.............................................59 4762.............................................59 4763.............................................59 4764.............................................59 4766.............................................59 4768.............................................59 5001.............................................32 5002.............................................32 5003.............................................75 5006.............................................75 5007.............................................75 5008.............................................75 5013.............................................32 5018.............................................75 5020.............................................32 5027.............................................75 5031.............................................40 5032.............................................40 5050.............................................78 5065.............................................78 5066.............................................78 5067.............................................78 5078.............................................38 5088.............................................38 5090.............................................39 5092.............................................36 5102.............................................36 5103.............................................32 5104.............................................32 5105.............................................75 5106.............................................75 5119.............................................32 5178.............................................38 5192.............................................36 5193.............................................35 5250.............................................73 5251.............................................73 5252.............................................73 5253.............................................73 5254.............................................73 5255.............................................73 5283.............................................72 5284.............................................72 5285.............................................72 5286.............................................72 5301.............................................31 5302.............................................31 5303.............................................74 5304.............................................74 5307.............................................74 5351.............................................31 5352.............................................31 5353.............................................74 5355.............................................31
5356.............................................74 5388.............................................38 5392.............................................36 5393.............................................35 5473.............................................71 5474.............................................71 5475.............................................71 5476.............................................71 5477.............................................71 5501.............................................53 5502.............................................53 5503.............................................53 5504.............................................53 5505.............................................53 5506.............................................53 5550.............................................53 5552.............................................53 5553.............................................53 5554.............................................53 5555.............................................53 6330.............................................39 6360.............................................37 6361.............................................37 6501.............................................32 6508.............................................32 6713.............................................57 6714.............................................57 6716.............................................57 6718.............................................57
4402-6718
Genesis® Series Cable
Responsive, reliable, world-class service that works with you. Backed by a Fortune 100 company that sets the standard across numerous industries, our robust support system is second to none. It has enabled us at Honeywell Cable to build our entire organization around creating the best, hassle-free experience for our customers. It drives everything we do, including our:
Thousands of locations across the
Toll-free, LIVE customer
Free freight with orders of
security, low-voltage, electrical and
service and sales support at:
$1,500 or more. By stocking up for
HVAC distribution channels where our
800-222-0060. Get immediate,
upcoming jobs, we help you save
Honeywell Genesis® Series cable is
responsive assistance when you
time and money over the long haul.
readily available for quick delivery or
need it!
pick up.
ReadySHIP – over 100 current
Cable for That! app – Provides an
Robust, industry-leading warranties
products that ship same day (for
easy-to-use and accessible guide
– Backing up our commitment to
orders placed prior to 3:00 p.m., after
that helps you choose the right
quality, we have gone to great lengths to
3:00 p.m. ships next day) – list
cable for your application – go to our
offer standard or extended agreements
available on our website or by calling
website and use your mobile device to
on our entire range of
customer service.
download the app that’s right for you.
innovative products.
Please visit www.honeywellcable.com for more information, including a detailed cable catalog.
Cable engineered by the equipment manufacturer.
At Honeywell Cable, we strive to be the most trusted, go-to brand for low-voltage cable across a wide range of applications. By providing quality wiring products and responsive, reliable world-class service, our mission is to enable your success every day. Security, fire, network, HVAC, audio/video, control … whatever your application, “We’ve got a Cable for That!” Visit www.honeywellcable.com to see our full product listing of low-voltage wire and cable, including: • Security • Fire • IP – Network • Thermostat • Sound • And much more!
For more information: www.honeywellcable.com For mobile devices: m.honeywellcable.com Honeywell Cable 7701 95th Street Pleasant Prairie, WI 53158 800.222.0060 www.honeywell.com
L/CBLPRD16CT/D 12/16 © 2016 Honeywell International Inc.