Preview only show first 10 pages with watermark. For full document please download

2017 Low-voltage Cable Catalog

   EMBED


Share

Transcript

Genesis® Series Cable 2017 LOW-VOLTAGE CABLE CATALOG Our Commitment to You At Honeywell Cable, we strive to be the most trusted, go-to brand for low-voltage cable across a wide range of applications. By providing quality wiring products and responsive, reliable world-class service, our mission is to work with you to enable your success every day. Our industry-leading processes ensure you easily receive exactly what you need, when you need it, where you need it. Complete Product Line Works With You Quality & World-Class Reliability Service Innovative Solutions Table of Contents Introduction to Honeywell Cable ................................................................................................................................................................... 4 Most Popular Cables.................................................................................................................................................................................... 5 Part Numbers, Packaging and Color Codes ..................................................................................................................................... 12 Conductor Color Code Charts................................................................................................................................................................ 13 Security Cables | Article 725/800 .............................................................................................................................................................. 15 Plenum........................................................................................................................................................................................................... 16 CSA Listed .................................................................................................................................................................................................... 19 Riser ................................................................................................................................................................................................................ 20 General Purpose ......................................................................................................................................................................................... 22 Access Control Cables .................................................................................................................................................................................... 25 Plenum........................................................................................................................................................................................................... 26 Riser ................................................................................................................................................................................................................ 27 Video Surveillance Cables ............................................................................................................................................................................. 29 Network & IP Cables | Article 800 .............................................................................................................................................................. 33 Cat 6A ............................................................................................................................................................................................................. 35 Cat 6 Plus ...................................................................................................................................................................................................... 36 Cat 6................................................................................................................................................................................................................ 37 Cat 5e ............................................................................................................................................................................................................. 38 Cat 3................................................................................................................................................................................................................ 40 Fire Alarm Cables | Article 760 .................................................................................................................................................................... 41 Plenum........................................................................................................................................................................................................... 42 Riser ................................................................................................................................................................................................................ 45 General Purpose ......................................................................................................................................................................................... 48 Metal Clad .................................................................................................................................................................................................... 50 Direct Burial ................................................................................................................................................................................................. 51 CSA Listed .................................................................................................................................................................................................... 52 New York City Local Law 5 ...................................................................................................................................................................... 53 HVAC & Thermostat Control Cables .......................................................................................................................................................... 55 Hybrid............................................................................................................................................................................................................. 57 General Purpose ......................................................................................................................................................................................... 58 Plenum........................................................................................................................................................................................................... 59 Mini-Split ...................................................................................................................................................................................................... 60 Intelligent Building System (IBS) Cables ................................................................................................................................................. 61 BACnet/EIA-485 ........................................................................................................................................................................................ 62 Echelon® LonWorks® ................................................................................................................................................................................. 63 Lutron®........................................................................................................................................................................................................... 64 Irrigation/Tracer & Lighting Cables .......................................................................................................................................................... 65 Underground Lighting ............................................................................................................................................................................. 66 Irrigation/Tracer......................................................................................................................................................................................... 67 Audio/Video Cables ......................................................................................................................................................................................... 69 Audacious® Premium Audio ................................................................................................................................................................... 71 Home Theater Sound ................................................................................................................................................................................ 73 Video ............................................................................................................................................................................................................... 74 Multimedia Cables | Article 725 .................................................................................................................................................................. 77 Technical Data, Tools & Resources............................................................................................................................................................. 79 Index ..................................................................................................................................................................................................................... 87 Select the best cable for that… Insist on quality and reliability you can trust. Insist on Honeywell Genesis® Series Cable. Genesis Series low-voltage cables are produced with innovative equipment and technology in our state-of-the-art facility in Pleasant Prairie, Wisconsin. We offer a complete portfolio of quality cable to meet your business needs. Cable for That! Apps – Information On the Go Insisting on quality and reliability you can trust means insisting on Honeywell Cable. When it’s time to select the best cable for your application, download the Security or HVAC Cable for That! mobile app and get all the answers you’re looking for. Just another way of giving you the tools you need to succeed, these mobile apps are available on both Apple® and Android® devices. 4 | www.honeywellcable.com Genesis® Series Cable Most Popular Cables Security Page Fire Alarm Page 22/2 Solid CM/CL2 1101 22 22/4 Solid FPL 4101 48 22/2 Stranded CM/CL2 1102 22 18/2 Solid FPL 4106 48 22/4 Solid CM/CL2 1103 22 18/4 Solid FPL 4107 48 22/4 Stranded CM/CL2 1104 22 16/2 Solid FPL 4111 48 18/2 Stranded CM/CL2 1118 22 16/4 Solid FPL 4112 48 18/4 Stranded CM/CL2 1119 22 14/2 Solid FPL 4113 48 22/2 Stranded CMP/CL2P 3102 16 18/2 Solid FPLR 4306 46 22/4 Stranded CMP/CL2P 3104 16 18/4 Solid FPLR 4307 46 18/2 Stranded CMP/CL2P 3114 16 18/2 Solid FPLP 4506 42 18/4 Stranded CMP/CL2P 3115 16 18/4 Solid FPLP 4507 42 16/2 Solid FPLP 4511 42 Page 16/4 Solid FPLP 4512 42 14/2 Solid FPLP 4513 42 Video Surveillance RG59 BC Braid CL2 5001 32 RG59 CCA Braid + 18/2 CL2 6508 32 RG59 BC Braid + 18/2 CL2 5013 32 RG BC Braid + 18/2 CL2P 5355 31 16/2 Stranded AUDACIOUS® CL3R Page 16/4 Stranded AUDACIOUS® CL3R 5474 71 16/3 Stranded CL3 5250 73 73 Access Control PROFUSION™ Unjacketed Bundle CMR/CL2R (22/6 OAS + 22/2 + 22/4 + 18/4) PROFUSION™ Unjacketed Bundle CMP/CL2P (22/6 OAS + 22/2 + 22/4 + 18/4) 2195 3195 27 26 Audio/Video Page 5473 16/4 Stranded CL3 5251 RG6 Quad-Shielded CATV 5007 75 RG6 Dual-Shielded CATV 5003 75 Networking/IP HVAC/Thermostat Page Page Cat 5e CM 6330 39 Cat 5e CMR 5078 38 38 5 Conductor Hybrid CL2 6713 57 6 Conductor Hybrid CL2 6714 57 8 Conductor Hybrid CL2 6716 57 10 Conductor Hybrid CL2 6718 57 18/2 Solid CL2 4710 58 18/3 Solid CL2 4711 58 18/4 Solid CL2 4712 58 18/5 Solid CL2 4713 58 18/6 Solid CL2 4714 58 18/8 Solid CL2 4716 58 Genesis® Series Cable 71 Cat 5e CMP 5088 Cat 5e Direct Burial 5090 39 Cat 6 CMR 6360 37 Cat 6 CMP 6361 37 Cat 6 Plus CMR 5092 36 Cat 6 Plus CMP 5102 36 Cat 6A CMR 5193 35 Cat 6A CMP 5393 35 www.honeywellcable.com | 5 Innovation that never stops At Honeywell Cable, we know our customers demand innovation, and they deserve it. This is what drives us to always work to make our products and services better. Our goal is clear: provide the most reliable products, easiest installations and robust support. Here are just some of the ways we’ve recently responded with new, innovative technology: Category Cable – Responding to greater bandwidth and security demands, we have rounded out our line of network category cable to meet current and future technological requirements: • Cat 6A – for maximum bandwidth capable of handling 10G and 7G-wireless demands. • Cat 5e/6 Plus Shielded Options – for increasingly larger and more sensitive data applications. • Cat 6 (Yellow) – for a wider range of applications. HVAC Cable – When it comes to installing and connecting to HVAC systems, our cable is specifically engineered to handle evolving technologies and deliver exactly what our customers need: • Hybrid Thermostat – lighter weight cable is first designed specifically for power requirements of the circuit. • Metal Clad Mini Split – sunlight-resistant and suitable for direct burial – install without conduit. • Mini-Split 50' Convenience Packs – job-sized coils that simplify pricing, ordering and inventory. Fire Cable – Designed for optimal safety and manufactured in a wide variety of gauge sizes, shielding configurations and jacketing materials, including plenum, riser and general purpose: • Striped Fire Wire – easy to identify different cables without marking or tracing in a bundle. • Metal Clad Fire Wire (coming soon) - Dual-listed MC and FPL for NPLFA or PLFA fire alarm circuits – no need for conduit. Audacious® Sound Cable – 12-gauge option for longer run that rounds out our line of high-quality audio cable – providing optimal conductivity, signal integrity and ease of installation. Access Control Cable – As building access and control systems become more intelligent, it’s vital that the cable connecting them keep pace with technology. Our cable does just that: • Profusion – cost-effective, revolutionary twisting scheme to hold pairs together without binding. • Overall Jacket (OAJ) – easy to strip, snag-resistant, with countdown markings – for faster, hassle-free installations. Packaging – Working with installers rather than against them, our innovative cable packaging addresses common installation challenges, saving time, money and on-the-job headaches: • REACT™ Packaging – delivers consistent tangle-free performance. • Speed Bag® Packaging – save space, time and money, stacking multiple wires in a single bucket. • SPEED BOX® Packaging – for smoother, faster installations, it comes in Pull Box or Reel-In-A-Box. For more information please call 1-800-222-0060 or visit www.honeywellcable.com 6 | www.honeywellcable.com Genesis® Series Cable Innovations in Packaging REACT™ Packaging This innovative cable packaging addresses common installation challenges, working with installers rather than against them. With no adjustments, dials or settings necessary, this is an ideal solution to the aggravating problem of tangled cable. The inertia brake design allows the cable to pull easily when you want it and stop when you don’t. With its reinforced side-wall and payout opening design, it offers superior crush resistance and stacking and handling performance. And with its 100% recyclable cardboard design, it is also extremely convenient to dispose of on a job site. Speed Bag® Packaging Save space, time and money with Speed Bag, and get another innovative packaging solution that works with you to make installations more efficient and Fewer tangles means: hassle-free. Speed Bag provides: • Less labor • Less packaging for easier storage and transportation • A lighter weight design for reduced freight expenses • Faster and easier pulls – saving time and headaches on the job • Less wasted cable • Fewer on-the-job headaches • A more productive crew • Ability to stack multiple wire types in a single bucket – just pull the wire you need • A plastic overwrap that reduces waste and is moisture resistant SPEED BOX® Packaging Engineered for smoother and faster installations, SPEED BOX is another packaging innovation that helps enable your success every day. All boxes of Honeywell Cable, except REACT packaging, feature SPEED BOX – with two options to deliver cable: • Pull Box • Reel-In-A-Box Genesis® Series Cable www.honeywellcable.com | 7 www.h honeyw neywellc ellca llca l able.c blle.c e.c .c com | 7 Works with You Here’s why Honeywell Cable is the right partner for you: We provide customers all over North and South America with industry-leading, high-quality cable, including security, fire, control, thermostat, home theater, multimedia, networking, coax cables, and structured wiring for homes and commercial buildings. Our trusted experience, combined with the quality and reliability of our products, allows customers to meet their existing and emerging connectivity challenges. We offer cables that fit every budget for virtually any installation, including security, HVAC, home automation and control, networking, fire and video applications, and more. And, our pioneering product development only scratches the surface – we know that a trustworthy partnership is a prerequisite to a mutually profitable business relationship. With this in mind, Honeywell Cable stands on the partnership principles of: Commitment Innovation Support We’re committed to you, We deliver the newest We provide support and training our independent dealers, innovations, technologies to keep you ahead integrators and end-users. and products. of the competition. You are our business, and we are your partner who works with you. Support from Honeywell Cable — 800-222-0060 Honeywell Cable’s outstanding sales/customer service and technical support is second to none in the low-voltage cable industry. We are equipped with an extensive network of services that include: toll-free technical support and customer service, online technical documents and cross reference. Toll-free Support: Through our toll-free support line, customers get immediate help with troubleshooting from Honeywell Cable’s product experts. Each call is treated with the utmost importance to ensure each customer gets the immediate response they need, when they need it. Customer Service: Honeywell Cable’s customer service and sales representatives stand ready to answer questions. Customers can rest assured that they will get the support they need through every stage of the process. Sales Support: To help customers optimize the many features of their cable and structured solutions, Honeywell Cable provides on-site training for customers. 8 | www.honeywellcable.com Genesis® Series Cable readySHIP – Maximize Opportunities to Impress Your Customers Provide certainty in an uncertain business environment by supporting your customers’ ability to forecast inventory and optimize cash flow. Honeywell Cable's readySHIP program will enhance your overall service level and improve your performance in the process. Each readySHIP product will ship right away, allowing you to win more often and keep your business on schedule. Over 100 current products will ship same day (for orders placed prior to 3:00 p.m., after 3:00 p.m. ships next day) – the list is available on our website or by calling customer service (800-222-0060). Contractor PRO™ – Your Business Counts We’re making it as easy as we can to help you grow your business. As a member of Honeywell’s Contractor PRO program, you’ll earn rebate points on every Honeywell Cable product purchase you make. But that’s only the beginning. With Contractor PRO, you’ll enjoy a variety of ways to add more profit to your business. Member benefits include: • Exclusive technical support (877-880-3383) • Online referrals • FREE sales literature • Personal use product discounts • Regular communications, promotions and account updates For more information, including a complete and current listing of qualifying product part numbers, visit www.contractorpro.com and sign up today! Wire Merchandising System – Making Life Easier for Contractors As an accessory, it’s important to call attention to cable in order to make it easy for contractors to find what they need right away by merchandising them effectively. These easy-to-install kits don’t require any tools. Simply reserve a small section of your gondola shelves to clear a complete vertical section 36" wide. Our merchandising kits are designed to work with you, and are available with most Honeywell Cable package types – Speed Bags®, Spools, Reels, Buckets, etc. Thermostat wire, control cable and mini-split cable should all be represented near the counter when contractors walk in. Genesis® Series Cable www.honeywellcable.com | 9 Customer Testimonials “I can always count on Honeywell Genesis® Series Cable to be competitively priced, have what I need in stock, make it easy to find the part I’m looking for and place an order. I refer to its user-friendly catalog and website all the time.” – Lee Thompson, Beacon Light Supply, Hartford, CT “Honeywell Genesis® Series Cable consistently delivers dependable products that our customers prefer. The sales, distribution and customer service aspects of the business cater specifically to distributors and consumers like none other. With superior innovation and response to the market, Honeywell Cable is always a premium choice for our business.” – John Schwartzel, Carrier Enterprise Southeast “Honeywell Cable’s reputation, quality and quick delivery times makes working with them a breeze – it helps me out tremendously. Not to mention, the Contractor PRO™ program makes it convenient for my customers and contractors to continue buying Honeywell products.” – Tommy Hudson, N.B. Handy, Lynchburg, VA “Honeywell Cable’s REACT™ packaging is a huge asset for installations. It pulls really easily, saving major time and frustration on the job.” – Jason, Security Solutions, NW, Bellingham, WA “We used to have a lot of issues with damaged cable and interference issues. Ever since switching to Honeywell Cable, however, our installs now go very smoothly and we continue to increase sales.” – Tony, AS Security, Hamilton, ON Canada “We like buying from Honeywell Cable for several reasons. The pricing is always very competitive, orders are consistently shipped and completed in a timely manner, and between our rep agency and our Honeywell rep, we couldn’t be happier with the service we get.” – Jeff “Tank” Harrington, Ed’s Supply Company, Inc., Nashville, TN 10 | www.honeywellcable.com Genesis® Series Cable Customer Service Our Commitment Never Stops To ensure you easily have exactly what you need, when and where you need it, Honeywell Cable’s Inside Sales team is here to help you with all your wire and cable questions and concerns. Support areas include: • Cross referencing competitor parts • Stock inquiries, including lead times and product availability • Technical product information and cable applications • Processing special requests for minimums, colors, details, labeling, etc. • Dealer, representative and distributor information • Fulfilling catalog and sample requests Our representatives are available between 7:30 a.m. and 5:00 p.m. Central Standard Time. No matter what your question, we welcome the opportunity to speak with you. Call us at: 800-222-0060. Honeywell Cable Website - www.honeywellcable.com Comprehensive Online Resource In our ongoing efforts to continually provide you with what you need to be successful every day, we have many useful tools that can be accessed through our website such as: • Downloadable product resources, including collateral, videos and complete specs • Company and industry news • Updates on new product innovations • Featured product spotlights • Product selection and competitor cross-reference guides • Distributor and dealer locator information Genesis® Series Cable www.honeywellcable.com | 11 Genesis® Series Cable Part Numbers, Packaging and Color Codes All Genesis® Series Cable products come with an eight digit part number: • The first four digits represent the product • The next two digits represent the packaging • The last two digits represent the color code COLORS Color Code For Example: Color This is a 500' Pull Box of Black 00 Clear RG6U 60% AL 01 White 5003 = RG6U 60% AL 02 Yellow 55 = 500' Pull Box 03 Orange 08 = Black 04 Red 05 Green PACKAGING Packaging Code Put up 01 250' Reel 03 4 x 250' Reel 05 250' SPEED BOX® Pull Box 09 250' Speed Bag® 10 1000' Reel 11 1000' SPEED BOX® Pull Box 18 1000' Speed Bag® 21 1000' SPEED BOX® Reel-In-A-Box 25 2500' Reel 39 5 x 50' Coil 06 Blue 07 Brown 08 Black 09 Gray 10 Purple 11 Pink 12 Natural 13 Beige 40 Violet 41 Fluorescent Pink 45 Neon Green 99 Unjacketed 1G White w/ Green Stripe 1A White w/ Orange Stripe White w/Red Stripe 43 100' Reel 1R 46 125' Speed Bag® 4B Red w/Blue stripe 48 4 x 500' Reel 4G Red w/Green Stripe 54 500' Reel (1 of 4-pack) 4K Red w/Black Stripe 55 500' SPEED BOX® Pull Box 4P Red w/Purple Stripe 58 500' Speed Bag® 4W Red w/White Stripe 61 500' SPEED BOX® Reel-In-A-Box 4Y Red w/Yellow Stripe 86 1000' REACT™ Packaging 6R Blue w/Red Stripe 87 500" REACT™ Packaging 6Y Blue w/Yellow Stripe * See Selection Guide on www.honeywellcable.com for complete list of product options. 12 | www.honeywellcable.com Genesis® Series Cable Conductor Color Code Charts CHART 1 CHART 2 MULTI CONDUCTOR CABLES (UP TO 12) MULTI PAIR CABLES Conductor Color Pair # 1 BLACK 1 BLACK/RED 2 RED 2 BLACK/WHITE 3 WHITE 3 BLACK/GREEN 4 GREEN 4 BLACK/BLUE 5 BROWN 5 BLACK/YELLOW 6 BLUE 6 BLACK/BROWN 7 ORANGE 8 YELLOW 9 PURPLE 10 GRAY 11 PINK 12 Cond 1/Cond 2 TAN EXCEPTION: 1103 and 2103 SOL = BLACK, RED, YELLOW, GREEN CHART 3 FIRE ALARM CABLES CHART 4 VOICE AND DATA CABLES CHART 5 THERMOSTAT WIRE Conductor Color Pair Color/Stripes Conductor 1 BLACK 1 BLUE + WHITE/BLUE 1 RED 2 RED 2 ORANGE + WHITE/ORANGE 2 WHITE 3 GREEN 3 GREEN+ WHITE/GREEN 3 GREEN 4 YELLOW 4 BROWN + WHITE/BROWN 4 BLUE 5 BROWN 5 YELLOW 6 BLUE 6 BROWN 7 PURPLE 7 ORANGE 8 PINK 8 BLACK 9 TAN 9 PINK 10 ORANGE 10 GRAY 11 BLACK/WHITE 11 TAN 12 RED/WHITE 12 PURPLE Genesis® Series Cable Color www.honeywellcable.com | 13 NOTES 14 | www.honeywellcable.com 1-800-222-0060 Genesis® Series Cable SECURITY CABLES Low-voltage wiring you can trust Ensuring you have the right cable for the right application, our multi-conductor cables are manufactured in a wide variety of gauge sizes, shielding configurations and ratings – including plenum, riser and general purpose – to meet a wide range of security demands. Get cable you can count on for critical applications like alarms, as well as reliable wiring for intercoms, speakers and other low-voltage circuits that are power limited. Features: • Countdown or sequential footage markings • Zone and room markings Article 725: Class 1, Class 2 and Class 3 remote-control, signaling and power limited circuits that are not an integral part of a device or appliance. The scope of this article may include systems such as burglar alarm, access control, sound, nurse call, intercom circuits, some computer network systems, some control circuits for lighting dimmer systems, and some low-voltage control circuits that originate from listed computer equipment. Article 800: Communications circuits, voice and data cables. The scope of this article covers: telephone, telegraph (except radio), voice and data. Class 2 and Class 3 Cables: Type CL2, CL2R, CL2P, CL3 CL3R, CL3P Communication Cables: Type CM, CMR, CMP Genesis® Series Cable www.honeywellcable.com | 15 Security Cables - Plenum Rated Construction Conductors Bare Copper Insulation Plenum PVC Shielding N/A Jacket Plenum PVC Ratings/Listings Listings CMP/CL2P/FT6 Voltage (max.) 300V Temperature (max.) 75° C max UNSHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') at 20°C Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 2 Solid Unshielded 18 17.6 0.104 7.8 3101 22 2 7 Strand Unshielded 16.9 26.0 0.116 8.7 3102 22 3 7 Strand Unshielded 16.9 26.0 0.120 11.6 3127 22 4 Solid Unshielded 18 17.6 0.120 12.8 3103 22 4 7 Strand Unshielded 16.9 26.0 0.133 14.4 3104 22 6 7 Strand Unshielded 16.9 26.0 0.158 20.4 3106 22 8 7 Strand Unshielded 16.9 26.0 0.171 25.9 3107 22 10 7 Strand Unshielded 16.9 26.0 0.202 32.9 3108 22 12 7 Strand Unshielded 16.9 26.0 0.208 38.0 3109 18 2 Solid Unshielded 6.52 32.1 0.142 15.7 3134 18 2 19 Strand Unshielded 6.66 32.2 0.148 16.0 3114 18 3 19 Strand Unshielded 6.66 32.2 0.162 32.0 3126 18 4 19 Strand Unshielded 6.66 32.2 0.172 28.3 3115 18 6 19 Strand Unshielded 6.66 32.2 0.206 40.0 3116 18 8 19 Strand Unshielded 6.66 32.2 0.224 54.4 3117 18 10 19 Strand Unshielded 6.66 32.2 0.264 69.2 3118 18 12 19 Strand Unshielded 6.66 32.2 0.275 81.5 3119 16 2 26 Strand Unshielded 4.19 34.6 0.180 25.3 3121 16 3 26 Strand Unshielded 4.19 34.6 0.190 35.1 3129 16 4 26 Strand Unshielded 4.19 34.6 0.210 45.6 3122 14 2 19 Strand Unshielded 2.62 36.0 0.208 35.4 3123 14 4 19 Strand Unshielded 2.62 36.0 0.246 67.1 3124 12 2 65 Strand Unshielded 1.65 36.0 0.252 54.1 3125 16 | www.honeywellcable.com Genesis® Series Cable Security Cables - Plenum Rated Construction Conductors Bare Copper Insulation Plenum PVC Shielding 100% Aluminum Foil + Drain Jacket Plenum PVC Ratings/Listings Listings CMP/CL2P/FT6 Voltage (max.) 300V Temperature (max.) 75° C max SHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 2 Solid Shielded 18 29.9 0.108 9.9 3201 22 2 7 Strand Shielded 16.9 44.0 0.120 11.0 3202 22 3 7 Strand Shielded 16.9 39.2 0.134 13.9 3227 22 4 Solid Shielded 18 26.5 0.124 14.9 3203 22 4 7 Strand Shielded 16.9 39.2 0.137 17.0 3204 22 6 7 Strand Shielded 16.9 26.0 .0162 23.3 3206 22 8 7 Strand Shielded 16.9 26.0 0.192 28.9 3207 22 10 7 Strand Shielded 16.9 26.0 0.216 35.2 3208 22 12 7 Strand Shielded 16.9 26.0 0.219 41.4 3209 18 2 19 Strand Shielded 6.66 59.3 0.156 19.3 3214 18 3 19 Strand Shielded 6.66 50.8 0.166 25.8 3226 18 4 19 Strand Shielded 6.66 50.8 0.182 32.2 3215 18 5 19 Strand Shielded 6.66 50.8 0.197 38.3 3276 18 6 19 Strand Shielded 6.66 32.2 0.216 40.2 3216 18 8 19 Strand Shielded 6.66 32.2 0.236 58.2 3217 18 10 19 Strand Shielded 6.66 32.2 0.276 72.3 3218 16 2 26 Strand Shielded 4.19 65.9 0.180 28.0 3221 16 4 26 Strand Shielded 4.19 55.6 0.210 49.1 3222 14 2 19 Strand Shielded 2.62 70.2 0.212 38.8 3223 14 4 19 Strand Shielded 2.62 58.6 0.238 69.1 3224 Genesis® Series Cable www.honeywellcable.com | 17 Security Cables - Plenum Rated Construction Conductors Bare Copper Insulation Plenum PVC Jacket Plenum PVC Ratings/Listings Listings CMP/CL2P/FT6 Voltage (max.) 300V Temperature (max.) 75° C max UNSHIELDED PAIRS AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 3 pairs 7 Strand Unshielded 16.9 26.0 0.196 22.6 3247 22 4 pairs 7 Strand Unshielded 16.9 26.0 0.219 28.8 3248 OVERALL SHIELDED PAIRS AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 2 pairs 7 Strand Shielded 16.9 32.9 0.182 18.8 3281 18 | www.honeywellcable.com Genesis® Series Cable Canada Only Security Cables - CSA Listed Construction Conductors Bare Copper Insulation Polypropylene Shielding N/A Jacket PVC Ratings/Listings Listings CM/CL2 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max UNSHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 4 Solid Unshielded 18 18.8 0.120 12.7 1133 18 2 19 Strand Unshielded 6.66 22.7 0.150 17.6 1170 Genesis® Series Cable www.honeywellcable.com | 19 Security Cables - Riser Rated Construction Conductors Bare Copper Insulation Polypropylene Shielding N/A Jacket PVC Ratings/Listings Listings CMR/CL2R/FT4 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max UNSHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 2 Solid Unshielded 18 18.8 0.106 8.0 2101 22 2 7 Strand Unshielded 16.9 18.5 0.116 9.2 2102 22 4 Solid Unshielded 18 18.8 0.120 12.3 2103 22 4 7 Strand Unshielded 16.9 18.5 0.135 13.4 2104 22 6 7 Strand Unshielded 16.9 18.5 0.158 18.5 2106 22 12 7 Strand Unshielded 16.9 18.5 0.208 35.5 2109 20 4 7 Strand Unshielded 10.5 20.5 0.157 20.9 2113 18 2 19 Strand Unshielded 6.66 22.7 0.150 16.0 2114 18 4 19 Strand Unshielded 6.66 22.7 0.174 28.1 2115 18 6 19 Strand Unshielded 6.66 22.7 0.208 40.0 2116 18 8 19 Strand Unshielded 6.66 22.7 0.228 53.0 2117 18 10 19 Strand Unshielded 6.66 22.7 0.268 66.6 2118 18 12 19 Strand Unshielded 6.66 22.7 0.276 78.8 2119 16 2 26 Strand Unshielded 4.19 23.2 0.176 23.9 2121 16 4 26 Strand Unshielded 4.19 23.2 0.205 42.5 2122 14 2 19 Strand Unshielded 2.62 23.9 0.210 35.1 2123 14 4 19 Strand Unshielded 2.62 23.9 0.246 66.1 2124 12 2 65 Strand Unshielded 1.65 24.9 0.264 52.7 2125 20 | www.honeywellcable.com Genesis® Series Cable Security Cables - Riser Rated Construction Conductors Bare Copper Insulation Polypropylene Shielding 100% Aluminum Foil + Drain Jacket PVC Ratings/Listings Listings CMR/CL2R/FT4 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max SHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 2 7 Strand Shielded 16.9 32.0 0.120 9.6 2202 22 4 Solid Shielded 18 28.7 0.127 13.9 2203 22 4 7 Strand Shielded 16.9 28.2 0.141 15.6 2204 22 6 7 Strand Shielded 16.9 18.5 0.162 21.6 2206 22 8 7 Strand Shielded 16.9 18.5 0.176 26.0 2207 22 10 7 Strand Shielded 16.9 18.5 0.204 31.2 2208 22 12 7 Strand Shielded 16.9 18.5 0.210 35.8 2209 18 2 19 Strand Shielded 6.66 42.9 0.154 18.7 2214 18 4 19 Strand Shielded 6.66 36.3 0.180 31.4 2215 18 6 19 Strand Shielded 6.66 22.7 0.214 41.9 2216 18 8 19 Strand Shielded 6.66 22.7 0.232 54.3 2217 18 10 19 Strand Shielded 6.66 22.7 0.268 68.3 2218 18 12 19 Strand Shielded 6.66 22.7 0.281 81.0 2219 16 2 26 Strand Shielded 4.19 44.3 0.180 26.4 2221 16 4 26 Strand Shielded 4.19 37.3 0.209 45.6 2222 14 2 19 Strand Shielded 2.62 46.4 0.216 38.0 2223 14 4 19 Strand Shielded 2.62 38.8 0.252 68.6 2224 Genesis® Series Cable www.honeywellcable.com | 21 Security Cables - General Purpose Rated Construction Conductors Bare Copper Insulation Polypropylene Shielding N/A Jacket PVC Ratings/Listings Listings CM/CL2 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max UNSHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 24 4 Solid Unshielded 28.6 17.2 0.108 9.2 1140 22 2 Solid Unshielded 18 18.8 0.104 7.2 1101 22 2 7 Strand Unshielded 16.9 18.5 0.114 8.8 1102 22 4 Solid Unshielded 18 18.8 0.120 12.4 1103 22 4 7 Strand Unshielded 16.9 18.5 0.137 14.0 1104 22 6 Solid Unshielded 18 18.8 0.140 17.4 1106 22 6 7 Strand Unshielded 16.9 18.5 0.158 19.4 1107 22 8 Solid Unshielded 18 18.8 0.152 22.2 1108 22 8 7 Strand Unshielded 16.9 18.5 0.172 24.1 1109 22 10 7 Strand Unshielded 16.9 18.5 0.200 27.6 1111 1112 22 12 Solid Unshielded 18 18.8 0.182 31.5 22 12 7 Strand Unshielded 16.9 18.5 0.204 34.0 1113 18 2 Solid Unshielded 6.52 22.8 0.136 14.6 1138 18 2 19 Strand Unshielded 6.66 22.7 0.148 14.7 1118 18 3 19 Strand Unshielded 6.66 22.7 0.159 21.3 1130 18 4 19 Strand Unshielded 6.66 22.7 0.172 26.9 1119 18 6 19 Strand Unshielded 6.66 22.7 0.206 39.2 1120 18 8 19 Strand Unshielded 6.66 23.2 0.232 54.0 1121 18 12 19 Strand Unshielded 6.66 22.7 0.277 78.9 1123 16 2 26 Strand Unshielded 4.19 23.2 0.172 23.6 1125 16 4 26 Strand Unshielded 4.19 23.2 0.202 41.7 1126 14 1 Solid Unshielded 2.57 Null 0.105 16.0 1131 14 2 19 Strand Unshielded 2.62 23.9 0.210 34.6 1127 12 2 65 Strand Unshielded 1.65 24.9 0.264 51.0 1129 22 | www.honeywellcable.com Genesis® Series Cable Security Cables - General Purpose Rated Construction Conductors Bare Copper Insulation Polypropylene Shielding 100% Aluminum Foil + Drain Jacket PVC Ratings/Listings Listings CM/CL2 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max SHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 2 7 Strand Shielded 16.9 32.0 0.120 9.7 1202 22 4 7 Strand Shielded 16.9 28.2 0.139 14.8 1204 22 6 7 Strand Shielded 16.9 18.5 0.166 21.0 1206 22 8 7 Strand Shielded 16.9 18.5 0.174 25.8 1207 22 10 7 Strand Shielded 16.9 18.5 0.204 31.6 1208 22 12 7 Strand Shielded 16.9 18.5 0.216 35.7 1209 20 2 7 Strand Shielded 10.5 36.9 0.138 14.8 1212 18 2 19 Strand Shielded 6.66 42.9 0.154 17.4 1214 18 3 19 Strand Shielded 6.66 36.3 0.161 24.4 1228 18 4 19 Strand Shielded 6.66 36.3 0.178 30.1 1215 18 6 19 Strand Shielded 6.66 22.7 0.210 42.4 1216 18 8 19 Strand Shielded 6.66 22.7 0.230 55.8 1217 18 10 19 Strand Shielded 6.66 22.7 0.270 69.6 1218 16 2 26 Strand Shielded 4.19 44.3 0.178 25.7 1221 16 3 26 Strand Shielded 4.19 37.3 0.186 35.2 1229 16 4 26 Strand Shielded 4.19 37.3 0.202 43.8 1222 14 2 19 Strand Shielded 2.62 46.4 0.214 39.1 1223 Genesis® Series Cable www.honeywellcable.com | 23 Security Cables - General Purpose Rated Construction Conductors Bare Copper Insulation Polypropylene Jacket PVC Ratings/Listings Listings CM/CL2 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max 1-PAIR SHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 2 pairs 7 Strand 1 Pair Shielded 16.9 32.0 0.185 16.7 1250 INDIVIDUALLY SHIELDED PAIRS AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 2 pairs 7 Strand Each Pair Shielded 16.9 32.0 0.165 16.7 1264 Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code UNJACKETED AWG 22 2 7 Strand Unshielded 16.9 24.1 0.150 9.0 1051 20 2 7 Strand Unshielded 10.5 27.4 0.170 14.2 1052 14 2 Solid Unshielded 2.57 27.4 0.228 34.0 1057 AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 2 7 Strand Unshielded 16.9 24.3 .074 x .164 7.5 1002 20 2 7 Strand Unshielded 10.5 23.7 .083 x .180 13.3 1003 18 2 19 Strand Unshielded 6.66 29.8 .090 x .190 15.1 1004 ZIP CORD 24 | www.honeywellcable.com Genesis® Series Cable ACCESS CONTROL CABLES Bundled technology for quicker installations Our highly engineered PROFUSION® access control cables use a revolutionary twisting scheme to hold pairs together without binding, preventing deterioration and making for easier installation – just tape the ends and pull. This represents the most cost-effective solution for bundled cable applications. • Countdown or sequential footage markings • Zone and room markings Overall Jacket Access Control Cable provides quick installations and smooth pulls. An overall jacket joins individual lock power, door contact, card reader, and request-to-exit cables into a single convenient cable. With an easier to strip overall jacket, snags are virtually eliminated, creating an overall hassle-free experience. Features: • Easy to strip overall jacket • Snag resistant • Countdown or sequential footage markings Genesis® Series Cable www.honeywellcable.com | 25 Access Control - Plenum Rated PROFUSION® Unjacketed • Reduces cold weather cracking and cable separation • Saves installation time • Components stay unified while pulling; separate easily at access point Overall Jacketed • Easy to strip overall jacket • Snag resistant • Countdown markings on jacket Ratings/Listings Listings CMP/CL2P FT6 Voltage (max.) 300V Temperature (max.) 75° C max PROFUSION UNJACKETED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) 18 4 19 Strand - 6.52 22.8 22 6 7 Strand Shielded 16.9 24.3 22 2 7 Strand - 16.9 24.3 22 4 7 Strand - 16.9 24.3 18 4 19 Strand Shielded 6.52 22.8 22 6 7 Strand Shielded 16.9 24.3 22 2 7 Strand Shielded 16.9 24.3 22 4 7 Strand Shielded 16.9 24.3 Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 0.395 77.2 3195 0.395 88.5 3295 Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 0.350 89.0 3196 0.400 100.8 3296 JACKETED AWG 18 4 19 Strand - 6.52 22.8 22 6 7 Strand Shielded 16.9 24.3 22 2 7 Strand - 16.9 24.3 22 4 7 Strand - 16.9 24.3 18 4 19 Strand Shielded 6.52 22.8 22 6 7 Strand Shielded 16.9 24.3 22 2 7 Strand Shielded 16.9 24.3 22 4 7 Strand Shielded 16.9 24.3 26 | www.honeywellcable.com Genesis® Series Cable Access Control - Riser Rated PROFUSION® Unjacketed • Reduces cold weather cracking and cable separation • Saves installation time • Components stay unified while pulling; separate easily at access point Overall Jacketed • Easy to strip overall jacket • Snag resistant • Countdown markings on jacket Ratings/Listings Listings CMR/CL2R FT4 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max PROFUSION UNJACKETED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) 18 4 19 Strand - 6.52 22.8 22 6 7 Strand Shielded 16.9 24.3 22 2 7 Strand - 16.9 24.3 22 4 7 Strand - 16.9 24.3 18 4 19 Strand Shielded 6.52 22.8 22 6 7 Strand Shielded 16.9 24.3 22 2 7 Strand Shielded 16.9 24.3 22 4 7 Strand Shielded 16.9 24.3 Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 0.410 69.5 2195 0.410 80.3 2295 Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 0.350 83.1 2196 0.390 96.2 2296 JACKETED AWG 18 4 19 Strand - 6.52 22.8 22 6 7 Strand Shielded 16.9 24.3 22 2 7 Strand - 16.9 24.3 22 4 7 Strand - 16.9 24.3 18 4 19 Strand Shielded 6.52 22.8 22 6 7 Strand Shielded 16.9 24.3 22 2 7 Strand Shielded 16.9 24.3 22 4 7 Strand Shielded 16.9 24.3 Genesis® Series Cable www.honeywellcable.com | 27 NOTES 28 | www.honeywellcable.com 1-800-222-0060 Genesis® Series Cable VIDEO SURVEILLANCE CABLES Optimal connectivity Honeywell’s Genesis® Series CCTV* Coaxial cables are engineered to deliver sharp, smooth video signals at an optimal value. Features: • Countdown or sequential footage markings • Room/Zone markings on legend • Color coded boxes • 100% guaranteed Genesis® Series Cable www.honeywellcable.com | 29 Conductor Material Bare Copper (BC): • Excellent signal strength for low-frequency applications such as CCTV* • Other materials such as copper clad steel and copper clad aluminum compromise signal integrity and video quality Shielding Braid Shield: • 95% Bare Copper standard or 95% Copper Clad Aluminum for shorter economical runs • Protects signal transmission from low-frequency interference, EMI* • Ideal for CCTV* or other low-frequency applications *CCTV: Closed Circuit Television *EMI: Electromagnetic Interference (from electric motors, ballasts, and nearby high-voltage currents) Power Conductors • Bare copper for low voltage drop • Other materials such as copper clad aluminum or copper clad steel can lead to excessive voltage drop, which leads to damage to devices and premature failure 30 | www.honeywellcable.com Genesis® Series Cable Video Surveillance Plenum Construction Coax Center Conductor Bare Copper Power Conductors Bare Copper Coax Shielding 95% Bare Copper Braid Jacket Plenum PVC Ratings/Listings Listings CMP/CL2P/FT6 Voltage (max.) 300V Temperature (max.) 75° C max Riser Construction Coax Center Conductor Bare Copper Shielding 95% Bare Copper Braid Jacket PVC Ratings/Listings Listings CMR/CL2R/FT4 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max PLENUM RATED Style Shield DC Resistance (Ohms/1000') Velocity of Propagaton (%) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') 18 RG6 95% BC 6.52 78% 16.5 0.226 47.0 5352 20 RG59 95% BC 11.1 78% 16.5 0.195 39.0 5351 20 RG59+18/2 95% BC 11.1 78% 16.5 .420 x .200 65.0 5355 Style Shield DC Resistance (Ohms/1000') Velocity of Propagaton (%) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 18 RG6 95% 6.52 78% 17.3 0.275 40.0 5302 20 RG59 95% 11.1 78% 17.3 0.242 32.0 5301 AWG Product Code RISER RATED AWG Genesis® Series Cable www.honeywellcable.com | 31 Video Surveillance General Purpose Construction Center Conductor Bare Copper Power Conductors Bare Copper Shielding 95% Braid Jacket PVC Ratings/Listings Listings CM/CL2 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max Water Resistant Construction Center Conductor Bare Copper Power Conductors Bare Copper Shielding 95% Braid Jacket PVC Ratings/Listings Listings Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max GENERAL PURPOSE RATED Style Shield DC Resistance (Ohms/1000') Velocity of Propagaton (%) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) 18 RG6 95% BC 6.52 78% 17.3 0.275 42.0 5002 20 RG59 95% BC 11.1 78% 17.3 0.242 36.0 5001 20 RG59 95% CCA 11.1 78% 17.3 0.242 30.0 6501 24 75 Ohm 95% BC 28.6 78% 17.3 0.145 15.0 5020 18 RG6+18/2 95% BC 6.52 78% 17.3 .450 x .275 66.0 5119 20 RG59+18/2 95% BC 11.1 78% 17.3 .420 x .245 60.0 5013 20 RG59+18/2 95% CCA 11.1 78% 17.3 .425 x .240 42.8 6508 Style Shield DC Resistance (Ohms/1000') Velocity of Propagaton (%) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 20 RG59 95% BC 11.1 78% 17.3 0.242 36.0 5103 20 RG59+18/2 95% BC 11.1 78% 17.3 .421 x .245 65.0 5104 AWG Average Weight (Pounds/1000') Product Code WATER RESISTANT RATED AWG 32 | www.honeywellcable.com Genesis® Series Cable NETWORK & IP CABLES Wired for success Honeywell Genesis® Series Cable satisfies a wide range of power demands with its well-rounded, versatile category cable portfolio – now including Cat 6A and Cat 5e/6 Plus shielded cables. With options for increasing signal speed, improving interruption-free connectivity and strengthening overall data security, there’s a category cable for virtually every application. Features: • Countdown or sequential footage markings • Room numbers on legend • 100% guaranteed Article 800: Communications circuits, voice and data cables. The scope of this article covers: telephone, telegraph (except radio), voice and data Communication Cable: Type CM, CMR, CMP Genesis® Series Cable www.honeywellcable.com | 33 Category Cable Quick-Selection Guide Type Cat 5e Cat 6 Cat 6 Plus Cat 6A Network Throughput 100 Mb (100m) 1 Gb (30m) 1 Gb (100m) 10 Gb (30m) 1 Gb (100m) 10 Gb (30m) 10 Gb (100m) 40 Gb (30m) Maximum PoE Power at PD Up to 12.95 W (802.3af/PoE) Up to 25.5 W (802.3at/PoE+) Up to 60 W (802.3bt/ PoE++)* 60 W and beyond* (802.3bt/PoE++)* Typical Applications • 802.11 a/b/g hot spot • Regular IP/network camera • IP phone • Access control/ badge reader • Intercom/paging/public address system • Wall clock/message board/ • SISO 802.11n hot spot • HD IP/network camera • Video phone • MIMO 802.11n hot spot • Outdoor PTZ camera with heater and blower • Thin client • Point of Sales • Video conferencing system • Nurse call system • 802.11ac hot spot • HDBT hub for audio/ video equipment Unshielded: 6360, 6361 Unshielded: 5092, 5102 Unshielded: 5193, 5393 lighting control Product Codes Unshielded: 6330, 5078, 5088, 5090 Shielded: 5192, 5392 Shielded: 5178, 5388 :OPLSKLK]LYZPVUVќLYZ greater noise and emission WYV[LJ[PVUMVYJVUÄKLU[PHS mission critical applications) :OPLSKLK]LYZPVUVќLYZ greater noise and emission WYV[LJ[PVUMVYJVUÄKLU[PHS mission critical applications) *P802.3bt IEEE draft standard 34 | www.honeywellcable.com Genesis® Series Cable Network & IP - Cat 6A Construction Riser Conductors Bare Copper Plenum Insulation PP or PE Spline Dielectric Between Pairs FEP Jacket PVC PVC Listings CMR/CL2R/FT4 Sunlight Resistant CMP/CL2P/FT6 Voltage (max.) 300V 300V Temperature (max.) 75° C max 75° C max Ratings/Listings CAT 6A - PLENUM RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 23 4 pairs UTP (Unshielded) 22.3 100 14.9 0.320 45.0 5393 CAT 6A - RISER RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 23 4 pairs UTP (Unshielded) 22.3 100 14.9 0.350 44.0 5193 Genesis® Series Cable www.honeywellcable.com | 35 Network & IP - Cat 6 Plus Construction Riser Conductors Bare Copper Plenum Insulation PP or PE Spline Dielectric Between Pairs FEP Jacket PVC PVC Ratings/Listings Listings CMR/CL2R/FT4 Sunlight Resistant CMP/CL2P/FT6 Voltage (max.) 300V 300V Temperature (max.) 75° C max 75° C max CAT 6 PLUS - PLENUM RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 23 4 pairs UTP (Unshielded) 22.3 100 14.9 0.240 28.2 5102 SHIELDED CAT 6 PLUS - PLENUM RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 23 4 pairs FTP (Shielded) 22.3 100 14.9 0.290 45.0 5392 CAT 6 PLUS - RISER RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 23 4 pairs UTP (Unshielded) 22.3 100 14.9 0.245 25.0 5092 SHIELDED CAT 6 PLUS - RISER RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 23 4 pairs FTP (Shielded) 22.3 100 14.9 0.280 35.0 5192 36 | www.honeywellcable.com Genesis® Series Cable Network & IP - Cat 6 Construction Riser Conductors Bare Copper Insulation PP or PE Spline None Jacket PVC Plenum FEP PVC Ratings/Listings Listings CMR/CL2R/FT4 Sunlight Resistant CMP/CL2P/FT6 Voltage (max.) 300V 300V Temperature (max.) 75° C max 75° C max CAT 6 - PLENUM RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 23 4 pairs UTP (Unshielded) 22.3 100 14.9 0.205 25.0 6361 CAT 6 - RISER RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 23 4 pairs UTP (Unshielded) 22.3 100 14.9 0.205 24.0 6360 Genesis® Series Cable www.honeywellcable.com | 37 Network & IP - Cat 5e Construction Riser Conductors Bare Copper Plenum Insulation PP or PE FEP Jacket PVC PVC Listings CMR/CL2R/FT4 Sunlight Resistant CMP/CL2P/FT6 Voltage (max.) 300V 300V Temperature (max.) 75° C max 75° C max Ratings/Listings CAT 5E - PLENUM RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 23 4 pairs UTP (Unshielded) 28.6 100 14.9 0.200 23.0 5088 SHIELDED CAT 5E - PLENUM RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 24 4 pairs FTP (Shielded) 28.6 100 14.9 0.240 33.0 5388 CAT 5E - RISER RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 24 4 pairs UTP (Unshielded) 28.6 100 14.9 0.210 20.0 5078 SHIELDED CAT 5E - RISER RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 24 4 pairs FTP (Shielded) 28.6 100 14.9 0.210 28.0 5178 38 | www.honeywellcable.com Genesis® Series Cable Network & IP - Cat 5e Construction Riser Conductors Bare Copper Plenum Insulation PP or PE PP Jacket PVC LLDPE Listings CM/CL2, Sunlight Resistant Direct Burial, Sunlight Resistant Voltage (max.) 300V 300V Temperature (max.) 75° C max 75° C max Ratings/Listings CAT 5E - GENERAL PURPOSE RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 24 4 pairs UTP (Unshielded) 28.6 100 14.9 0.200 19.0 6330 CAT 5E - DIRECT BURIAL RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 24 4 pairs UTP (Unshielded) 28.6 100 14.9 0.225 24.0 5090* *Pictured above Genesis® Series Cable www.honeywellcable.com | 39 Network & IP - Cat 3 Construction Riser Conductors Bare Copper Plenum Insulation PP PP Jacket PVC N/A Ratings/Listings Listings CMR/CL2R Sunlight Resistant Unlisted Voltage (max.) 300V 300V Temperature (max.) 75° C max 75° C max CAT 3 - RISER RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) 24 2 pairs UTP (Unshielded) 28.6 100 17.1 24 3 pairs UTP (Unshielded) 28.6 100 17.1 Average Weight (Pounds/1000') Product Code 0.150 9.9 5031 0.160 14.3 5032 CAT 3 - UNJACKETED CROSS-CONNECT AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 24 1 pair UTP (Unshielded) 28.6 88.3 17.23 0.064 2.9 1031 2 pairs UTP (Unshielded) 28.6 88.3 17.23 0.128 5.9 1032 24 40 | www.honeywellcable.com Genesis® Series Cable FIRE ALARM CABLES Connectivity you can rely on Designed for optimal safety, Honeywell Fire Alarm Cables are manufactured in a wide variety of gauge sizes, shielding configurations and ratings. We also manufacture fire alarm cables that meet the requirements of New York City Local Law 5 and New York State Toxicity requirements. Features: • Countdown or sequential footage markings • Innovative REACT™ packaging is available • Zone and room markings • UL or CSA listed Fire Cable Types: • General Purpose • Riser • Plenum • Direct Burial • NYC LL5 • CSA Listed FAS105 Article 760: The scope of this article covers the installation of wiring and equipment of fire alarm systems, including all circuits controlled and powered by the fire alarm system. These include fire detection and alarm notification, guard’s tour, sprinkler waterflow and sprinkler supervisory systems. Circuits controlled and powered by the fire alarm system include circuits for the control of building systems’ safety functions, elevator capture, elevator shutdown, door release, smoke doors and damper control, fire doors and damper control and fan shutdown. Applicable only where these circuits are powered by and controlled by the fire alarm system. Fire Power Limited Cable: Type FPL, FPLR, FPLP Genesis® Series Cable www.honeywellcable.com | 41 Fire Alarm - Plenum Rated Construction: Construction Conductors Bare Copper Insulation Plenum PVC Shielding N/A Jacket Plenum PVC Ratings/Listings Listings FPLP/CL2P/FT6 Voltage (max.) 300V Temperature (max.) 75° C max UNSHIELDED DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code Unshielded 18 17.6 0.143 18.0 4502 Unshielded 6.52 32.1 0.136 15.6 4506 19 Strand Unshielded 6.66 32.2 0.148 17.0 4524 4 Solid Unshielded 6.52 32.1 0.157 27.0 4507 18 4 19 Strand Unshielded 6.66 32.2 0.172 29.2 4525 18 6 Solid Unshielded 6.52 32.1 0.188 40.6 4508 16 2 Solid Unshielded 4.1 21.8 0.177 23.1 4511 16 4 Solid Unshielded 4.1 21.8 0.201 44.2 4512 14 2 Solid Unshielded 2.57 24.1 0.206 32.7 4513 14 2 19 Strand Unshielded 2.62 36.0 0.208 36.3 4522 14 4 Solid Unshielded 2.57 24.1 0.230 65.3 4514 12 2 Solid Unshielded 1.62 25.9 0.228 54.0 4515 12 2 65 Strand Unshielded 1.65 36.0 0.265 54.2 4521 AWG Number of Conductors Stranding Shield 22 6 Solid 18 2 Solid 18 2 18 42 | www.honeywellcable.com Genesis® Series Cable Fire Alarm - Plenum Rated Construction: Construction Conductors Bare Copper Insulation Plenum PVC Shielding 100% Aluminum Foil + Drain Jacket Plenum PVC Ratings/Listings Listings FPLP/CL2P/FT6 Voltage (max.) 300V Temperature (max.) 75° C max SHIELDED DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code AWG Number of Conductors 18 2 Solid Shielded 6.52 58.9 0.140 18.0 4602 18 2 19 Strand Shielded 6.66 37.3 0.156 19.8 4614 18 4 Solid Shielded 6.52 50.5 0.168 29.2 4603 18 6 Solid Shielded 6.52 32.1 0.192 43.2 4604 16 2 Solid Shielded 4.1 40.4 0.177 27.4 4606 16 4 Solid Shielded 4.1 34.5 0.206 46.1 4607 14 2 Solid Shielded 2.57 47.0 0.211 37.9 4608 14 2 19 Strand Shielded 2.62 70.2 0.213 42.5 4612 14 4 Solid Shielded 2.57 39.2 0.247 67.4 4609 12 2 Solid Shielded 1.62 52.5 0.245 62.1 4610 Genesis® Series Cable Stranding Shield www.honeywellcable.com | 43 Cable Striped Fire Wire: Simplifying Installations Innovation That Works with You Easily differentiate between circuits with Honeywell’s striped fire alarm cables. Expedite installations, and eliminate the hassle of marking and tracing cables in a bundle to identify the one you’re looking for. By assigning a different stripe color to each type of circuit on the job site, you will be able to maximize field productivity and minimize time wasted due to confusion. The stripes on these cables are extruded into the cables’ jackets so they won’t rub off like printed ink stripes. Like all Genesis® Series fire alarm cables, Honeywell’s striped fire alarm cables are UL listed and recommended for use in UL Certified Fire Alarm Systems. Honeywell Cable proudly manufactures striped fire alarm cables in Pleasant Prairie, WI, USA! Here’s a guide to the specific cable products and their stripe colors – all colors come in 1000' reels: DESCRIPTION 18/2 Solid Plenum (FPLP) 16/2 Solid Plenum (FPLP) 14/2 Solid Plenum (FPLP) 44 | www.honeywellcable.com JACKET COLOR PART NUMBER Red with Blue Stripe 4506104B Red with Black Stripe 4506104K Red with Purple Stripe 4506104P Red with White Stripe 4506104W Red with Yellow Stripe 4506104Y Red with Blue Stripe 4511104B Red with Black Stripe 4511104K Red with Purple Stripe 4511104P Red with White Stripe 4511104W Red with Yellow Stripe 4511104Y Red with Blue Stripe 4513104B Red with Black Stripe 4513104K Red with Purple Stripe 4513104P Red with White Stripe 4513104W Red with Yellow Stripe 4513104Y Genesis® Series Cable Fire Alarm - Riser Rated Construction Conductors Bare Copper Insulation Polypropylene Ratings/Listings Listings FPLR/CL2R/FT4 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max ZIP CORD AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 18 2 Solid Unshielded 6.52 29.9 .088 x .196 16.4 4422 16 2 Solid Unshielded 4.1 35.4 .094 x .200 23.3 4423 14 2 Solid Unshielded 2.57 39.5 .108 x .222 33.9 4424 Genesis® Series Cable www.honeywellcable.com | 45 Fire Alarm - Riser Rated Construction: Construction Conductors Bare Copper Insulation Polypropylene Shielding N/A Jacket PVC Ratings/Listings Listings FPLR/CL2R/FT4 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max UNSHIELDED DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code Unshielded 18 18.8 0.123 12.5 4301 Unshielded 6.52 22.8 0.138 14.7 4306 Solid Unshielded 6.52 22.8 0.159 26.1 4307 6 Solid Unshielded 6.52 22.8 0.190 40.0 4308 18 10 Solid Unshielded 6.52 22.8 0.244 63.2 4310 16 2 Solid Unshielded 4.1 22.3 0.165 22.5 4311 16 4 Solid Unshielded 4.1 22.3 0.201 40.2 4312 14 2 Solid Unshielded 2.57 24.1 0.192 32.1 4313 14 4 Solid Unshielded 2.57 24.1 0.225 60.7 4314 12 2 Solid Unshielded 1.62 25.9 0.226 49.8 4315 12 2 65 Strand Unshielded 1.65 24.9 0.264 53.8 4320 Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code AWG Number of Conductors Stranding Shield 22 4 Solid 18 2 Solid 18 4 18 UNSHIELDED MID-CAPACITANCE AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') 18 2 Solid Unshielded 6.52 20.5 0.144 15.4 4431 16 2 Solid Unshielded 4.1 20.6 0.170 23.4 4432 46 | www.honeywellcable.com Genesis® Series Cable Fire Alarm - Riser Rated Construction: Construction Conductors Bare Copper Insulation Polypropylene Shielding 100% Aluminum Foil + Drain Jacket PVC Ratings/Listings Listings FPLR/CL2R/FT4 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max SHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 18 2 Solid Shielded 6.52 42.9 0.142 17.2 4402 18 4 Solid Shielded 6.52 36.4 0.163 27.8 4403 18 6 Solid Shielded 6.52 22.8 0.194 41.5 4404 18 8 Solid Shielded 6.52 22.8 0.210 51.8 4405 16 2 Solid Shielded 4.1 41.7 0.168 24.7 4406 16 4 Solid Shielded 4.1 35.5 0.195 41.8 4407 14 2 Solid Shielded 2.57 46.9 0.205 35.6 4408 14 4 Solid Shielded 2.57 39.2 0.230 64.1 4409 12 2 Solid Shielded 1.62 52.5 0.231 56.8 4410 Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code SHIELDED MID-CAPACITANCE AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') 18 2 Solid Shielded 6.52 36.8 0.148 18.5 4441 16 2 Solid Shielded 4.1 33.5 0.187 24.4 4442 Genesis® Series Cable www.honeywellcable.com | 47 Fire Alarm - General Purpose Rated Construction: Construction Conductors Bare Copper Insulation Polypropylene Shielding N/A Jacket PVC Ratings/Listings Listings FPL/CL2 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max UNSHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 22 4 Solid Unshielded 18 18.8 0.120 11.3 4101 22 6 Solid Unshielded 18 18.8 0.140 16.9 4102 18 2 Solid Unshielded 6.52 22.8 0.136 14.6 4106 18 4 Solid Unshielded 6.52 22.8 0.165 28.6 4107 18 6 Solid Unshielded 6.52 22.8 0.188 37.1 4108 18 8 Solid Unshielded 6.52 22.8 0.210 48.2 4109 18 10 Solid Unshielded 6.52 22.8 0.246 62.3 4110 16 2 Solid Unshielded 4.1 22.3 0.172 21.2 4111 16 4 Solid Unshielded 4.1 22.3 0.201 40.5 4112 14 2 Solid Unshielded 2.57 24.1 0.192 31.8 4113 14 4 Solid Unshielded 2.57 24.1 0.225 59.2 4114 12 2 Solid Unshielded 1.62 25.9 0.226 51.5 4115 48 | www.honeywellcable.com Genesis® Series Cable Fire Alarm - General Purpose Rated Construction: Construction Conductors Bare Copper Insulation Polypropylene Shielding 100% Aluminum Foil + Drain Jacket PVC Ratings/Listings Listings FPL/Cl2 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max SHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 18 2 Solid Shielded 6.52 42.9 0.140 16.8 4202 18 4 Solid Shielded 6.52 36.4 0.161 28.2 4203 18 6 Solid Shielded 6.52 22.8 0.192 39.4 4204 18 8 Solid Shielded 6.52 22.8 0.214 49.9 4205 16 2 Solid Shielded 4.1 41.7 0.177 25.2 4206 14 2 Solid Shielded 2.57 46.9 0.195 34.4 4208 Genesis® Series Cable www.honeywellcable.com | 49 Fire Alarm - Metal Clad Construction: Construction Conductors Bare Copper Insulation THHN Shielding N/A Jacket PVC Cladding Aluminum Marking Helical red tape Ratings/Listings Listings Type MC, FPL Voltage (max.) 600V (Type MC), 300V (FPL) Temperature (max.) 90°C Dry / 75°C Wet UNSHIELDED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Outer Diameter (inches) Average Weight (Pounds/1000’) Product Code 18 2 + Ground Solid Unshielded 6.52 0.393 66.0 4290 18 4 + Ground Solid Unshielded 6.52 0.439 84.4 4291 16 2 + Ground Solid Unshielded 4.1 0.416 75.6 4292 16 4 + Ground Solid Unshielded 4.1 0.464 108.0 4293 14 2 + Ground Solid Unshielded 2.57 0.444 93.6 4294 14 4 + Ground Solid Unshielded 2.57 0.504 134.8 4295 12 2 + Ground Solid Unshielded 1.62 0.483 121.6 4296 50 | www.honeywellcable.com Genesis® Series Cable Fire Alarm - Direct Burial Rated Construction: Construction Conductors Bare Copper Insulation Semi-Rigid PVC Shielding N/A Jacket PVC Ratings/Listings Listings FPL/CL2 Direct Burial Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max UNSHIELDED DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') AWG Number of Conductors Stranding 18 2 19 Strand Unshielded 6.66 14.2 0.260 36.8 4156 18 4 19 Strand Unshielded 6.66 14.2 0.295 59.0 4157 18 6 19 Strand Unshielded 6.66 14.2 0.345 75.8 4158 18 8 19 Strand Unshielded 6.66 14.2 0.375 94.3 4159 16 2 26 Strand Unshielded 4.19 15.7 0.282 45.4 4151 16 4 26 Strand Unshielded 4.19 15.7 0.323 70.0 4152 14 2 19 Strand Unshielded 2.62 17.1 0.310 59.0 4153 14 4 19 Strand Unshielded 2.62 17.1 0.355 103.1 4154 Genesis® Series Cable Shield Part # www.honeywellcable.com | 51 Fire Alarm - CSA Listed Canada Only Construction: Construction Conductors Bare Copper Insulation PVC Shielding N/A Jacket PVC Ratings/Listings Listings Type FAS 105, FT4 Voltage (max.) 300V Temperature (max.) 75° C max UNSHIELDED DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code Unshielded 18 24.7 0.182 21.4 4026 Unshielded 6.52 28.1 0.207 25.7 4020 Solid Unshielded 6.52 28.1 0.218 33.2 4021 4 Solid Unshielded 6.52 28.1 0.235 42.0 4022 18 5 Solid Unshielded 6.52 28.1 0.256 50.0 4023 18 6 Solid Unshielded 6.52 28.1 0.281 59.2 4024 16 2 Solid Unshielded 4.1 31.0 0.227 33.6 4015 16 3 Solid Unshielded 4.1 31.0 0.240 44.2 4016 16 4 Solid Unshielded 4.1 31.0 0.260 55.4 4017 16 5 Solid Unshielded 4.1 31.0 0.288 68.0 4018 14 2 Solid Unshielded 2.57 34.1 0.253 45.2 4011 14 4 Solid Unshielded 2.57 34.1 0.295 78.6 4012 12 2 Solid Unshielded 1.62 37.4 0.291 64.8 4006 AWG Number of Conductors Stranding Shield 22 4 Solid 18 2 Solid 18 3 18 52 | www.honeywellcable.com Genesis® Series Cable Fire Alarm - New York City Local Law 5 Construction: Construction Conductors Bare Copper Insulation Fluoropolymer Jacket Fluoropolymer Ratings/Listings Listings FPLP/ NYC Certified Voltage (max.) 300V Temperature (max.) 150° C max UNSHIELDED Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') 18 4 Solid Unshielded 6.52 49.0 0.282 46.2 5501 16 2 Solid Unshielded 4.1 54.3 0.214 33.0 5502 16 4 Solid Unshielded 4.1 54.3 0.280 58.0 5503 14 2 Solid Unshielded 2.57 59.7 0.244 45.1 5504 14 4 Solid Unshielded 2.57 59.7 0.290 79.4 5506 12 2 Solid Unshielded 1.62 65.3 0.272 63.7 5505 AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 18 2 Solid Shielded 6.52 80.1 0.202 28.0 5550 16 2 Solid Shielded 4.1 91.7 0.218 35.1 5552 16 4 Solid Shielded 4.1 81.6 0.250 59.2 5553 14 2 Solid Shielded 2.57 104.4 0.248 47.3 5554 14 4 Solid Shielded 2.57 91.5 0.290 81.6 5555 Average Weight (Pounds/1000') Product Code SHIELDED Genesis® Series Cable www.honeywellcable.com | 53 NOTES 54 | www.honeywellcable.com 1-800-222-0060 Genesis® Series Cable HVAC & THERMOSTAT CONTROL CABLES Proven precision HVAC & Thermostat Cables: As the world’s leading thermostat manufacturer, no one knows home comfort systems better than Honeywell. Homeowners seeking a dependable HVAC system will only think about the wiring if it fails. Ensure that it doesn’t by selecting cable from a manufacturer that has the most enhanced and efficient cabling available. The flawless connection of Honeywell’s thermostat and mini split cables throughout the home provide the reliable comfort that homeowners value and you can count on. The new Hybrid thermostat and mini split options, including metal clad, are specifically engineered to tackle the evolving demands and functionality of thermostats and AC units. Plus, they now come in 50' convenience packs for easier handling. Features: • Full range of thermostat (for both older and newer, more energy-efficient models) and commercial control cables • Polypropylene insulation is an exceptional dielectric material, and strips easily and cleanly, saving time • Available for General Purpose (CL2) or Plenum (CL2P) applications • Packaging options: spools, Speed Bags® • 100% guaranteed Genesis® Series Cable www.honeywellcable.com | 55 Thermostat Cables Honeywell Thermostat Cables Work with You Speed Bag® Packaging Durable Rip Cords Room and Zone Markings Save time and hassle by choosing Strip jackets more easily without Easily label and identify rooms and ready-to-dispense, compact, and fully damaging conductors. zones using the convenient markings recyclable packaging. Hybrid Thermostat Cable: A Perfect Fit When it comes to installing a cable specifically engineered to handle the evolving demands and functionality of thermostats, Hybrid Thermostat Wire delivers exactly what you need: on the cable jacket. Hybrid Cables Come in a wide range of conductor constructions and packaging options. • First cable designed specifically for the power requirements of the circuit – all devices will be properly powered and controls will function as intended • Ideal for both new (energy-efficient) and existing HVAC equipment • Available in 5-, 6-, 8- and 10conductor constructions • Haul around less weight and win more project bids with Hybrid Cable • Comes in a variety of reel and Speed Bag packaging configurations 56 | www.honeywellcable.com Genesis® Series Cable Thermostat - Hybrid Construction: Construction Conductors Bare Copper Insulation Polypropylene Jacket PVC Ratings/Listings Listings CL2, Sunlight Resistant Voltage (max.) 150V Temperature (max.) 75° C max HYBRID THERMOSTAT - GENERAL PURPOSE RATED Description Genesis® Series Cable Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 5 Solid Conductors (1x18AWG + 4x20AWG) 0.140 22.3 6713 6 Solid Conductors (1x18AWG + 5x20AWG) 0.168 25.5 6714 8 Solid Conductors (1x18AWG + 7x20AWG) 0.180 32.5 6716 10 Solid Conductors (2x18AWG + 8x20AWG) 0.216 41.5 6718 www.honeywellcable.com | 57 Thermostat - General Purpose Construction: Construction Conductors Bare Copper Insulation Polypropylene Jacket PVC Ratings/Listings Listings CL2, Sunlight Resistant Voltage (max.) 150V Temperature (max.) 75° C max THERMOSTAT - GENERAL PURPOSE RATED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 20 2 Solid Unshielded 11.1 20.6 0.118 10.4 4701 20 3 Solid Unshielded 11.1 20.6 0.124 13.3 4702 20 4 Solid Unshielded 11.1 20.6 0.136 16.7 4703 20 5 Solid Unshielded 11.1 20.6 0.148 20.8 4704 20 6 Solid Unshielded 11.1 20.6 0.161 24.0 4705 20 7 Solid Unshielded 11.1 20.6 0.161 26.7 4706 20 8 Solid Unshielded 11.1 20.6 0.174 30.8 4707 18 2 Solid Unshielded 6.52 22.8 0.136 14.1 4710 18 3 Solid Unshielded 6.52 22.8 0.144 20.1 4711 18 4 Solid Unshielded 6.52 22.8 0.157 26.5 4712 18 5 Solid Unshielded 6.52 22.8 0.172 31.6 4713 18 6 Solid Unshielded 6.52 22.8 0.188 37.7 4714 18 7 Solid Unshielded 6.52 22.8 0.188 42.3 4715 18 8 Solid Unshielded 6.52 22.8 0.204 48.7 4716 18 9 Solid Unshielded 6.52 22.8 0.220 54.0 4717 18 10 Solid Unshielded 6.52 22.8 0.240 60.3 4718 18 12 Solid Unshielded 6.52 22.8 0.248 65.4 4719 58 | www.honeywellcable.com Genesis® Series Cable Thermostat - Plenum Construction: Construction Conductors Bare Copper Insulation Plenum PVC Jacket Plenum PVC Ratings/Listings Listings CL2P/FT6 Voltage (max.) 150V Temperature (max.) 75° C max THERMOSTAT - PLENUM RATED AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 18 2 Solid Unshielded 6.52 22.8 0.136 15.2 4760 18 3 Solid Unshielded 6.52 22.8 0.144 25.1 4761 18 4 Solid Unshielded 6.52 22.8 0.157 27.4 4762 18 5 Solid Unshielded 6.52 22.8 0.172 32.9 4763 18 6 Solid Unshielded 6.52 22.8 0.188 39.1 4764 18 8 Solid Unshielded 6.52 22.8 0.204 50.5 4766 18 10 Solid Unshielded 6.52 22.8 0.240 62.9 4768 Genesis® Series Cable www.honeywellcable.com | 59 Mini-Split Metal Clad Mini-Split Cables For systems where indoor unit is powered from the condenser. Mini-Split Tray Cables For systems where indoor unit is powered from the condenser. Low-Voltage Mini-Split Cables For systems where the interconnection cable is only for communication. JACKETED METAL CLAD - TYPE MC AWG Number of Conductors Stranding Shield Voltage Rating (max.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 14 4 7 Strand Unshielded 600V 0.574 153.0 1075 AWG Number of Conductors Stranding Shield Voltage Rating (max.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 16 4 19 Strand Unshielded 600V 0.350 75.0 1068 14 4 19 Strand Unshielded 600V 0.390 100.0 1070 14 7 19 Strand Unshielded 600V 0.460 155.5 1073 AWG Number of Conductors Stranding Shield Voltage Rating (max.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 18 4 19 Strand Shielded 300V 0.178 30.1 1215 16 2 26 Strand Shielded 300V 0.178 25.7 1221 18 2 19 Strand Unshielded 300V 0.148 14.7 1118 18 3 19 Strand Shielded 300V 0.161 24.4 1228 TRAY CABLE - TYPE TC LOW VOLTAGE 60 | www.honeywellcable.com Genesis® Series Cable INTELLIGENT BUILDING SYSTEM (IBS) CABLES Equipped for the most sophisticated applications As energy and security systems become increasingly intelligent, quality cable becomes an even more important factor. Communication cables used to network controlled circuits must be able to support high-speed data transfer for long distances. Because of this, it’s important to select the right cables that have low capacitance and correctly matched characteristic impedances. Produced in our state-of-the-art facility, Honeywell Cable also offers specialized IBS control cables that meet the requirements for Lutron® systems, BACnet and Echelon® LonWorks. Fire HVAC Detection Control & Alarm Genesis® Series Cable Intrusion Digital Detection Video Security Building & Access Automation Control Control www.honeywellcable.com | 61 IBS - BACnet/EIA-485 Construction Conductors Bare Copper Insulation FEP Shielding 100% Aluminum Foil + Drain Jacket Plenum PVC Ratings/Listings Listings CMP/CL2P/FT6 Voltage (max.) 300V Temperature (max.) 75° C max BACNET/EIA-485 - PLENUM RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 24 1 pair Shielded 26.7 115 12.5 0.164 21.3 3319 24 1.5 pairs Shielded 26.7 115 12.5 0.185 15.2 3323 22 1 pair* Shielded 16.9 100 14.5 0.183 19.6 3251 22 1 pair Shielded 16.9 115 12.5 0.166 15.5 3320 22 1.5 pairs Shielded 16.9 115 12.5 0.173 19.3 3324 22 2 pairs Shielded 16.9 115 12.5 0.192 24.3 3328 18 1 pair Shielded 6.66 115 12.5 0.256 29.9 3322 * Tinned-copper conductors 62 | www.honeywellcable.com Genesis® Series Cable IBS - Echelon® LonWorks® Construction: Construction Conductors Bare Copper Insulation FEP Shielding 100% Aluminum Foil + Drain Jacket Plenum PVC Ratings/Listings Listings CMP/CL2P/FT6 Voltage (max.) 300V Temperature (max.) 75° C max ECHELON LONWORKS - PLENUM RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 3252 22 1 pair Unshielded 16.9 100 15.3 0.120 10.0 22 2 pairs Unshielded 16.9 100 15.3 0.196 18.5 3253 22 1 pair Shielded 16.9 100 14.5 0.192 18.5 3254 22 2 pairs Shielded 16.9 125 11.7 0.265 29.2 3255 MISCELLANEOUS - PLENUM RATED AWG Number of Pairs Type DC Resistance (Ohms/1000') Impedance (Ohms) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 18 1 Shielded 6.66 58.1 26.21 0.190 24.6 4652 Genesis® Series Cable www.honeywellcable.com | 63 IBS - Lutron® Construction Conductors Bare Copper Insulation Polypropylene Shielding 100% Aluminum Foil + Drain Jacket PVC Ratings/Listings Listings CM/CL2 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max LUTRON - GENERAL PURPOSE Style Construction Shield Jacket Color Product Code Keypad Data/ GRAFIKEye® 3000 22/1pr Low Cap Data 18/2 Power Al/Mylar TC Drain Blue/Yellow Stripe 1244 GRAFIK Eye 4000/6000 22/1pr Low Cap Data 12/2 Power 18/1 Ground Al/Mylar TC Drain Blue 1260 Sivoia® Shades 18/4 BC 16/2 BC 18/1 BC Al/Mylar TC Drain None None Blue/Red Stripe 1287 64 | www.honeywellcable.com Genesis® Series Cable IRRIGATION/TRACER & LIGHTING CABLES Better protection, better performance Single Conductor Sprinkler and Tracer Wire: (UL Listed Sprinkler and Tracer Wire 600V) Designed for underground applications where harsh conditions may be encountered, tracer wire is ideal for buried applications as a way of easily identifying pipes and cables with a specific color code. Typically, tracer wire is color coded as follows: • Yellow - Gas Pipes • Blue - Water Pipes • Orange - Fiber Optic Cables • Green - Sewage Lines Another primary use for this cable is to connect the remote control valves of an irrigation system in a golf course sprinkler system. Landscape Lighting Cable: (UL Listed Underground Low Energy Circuit Cable 150V) Approved for direct burial and sunlight resistant, these cables are perfect for low-voltage direct burial lighting applications. Genesis® Series Cable www.honeywellcable.com | 65 Underground Lighting Construction Conductors Bare Copper Insulation/Jacket PVC Ratings/Listings Listings ULECC, Sunlight Resistant, Direct Burial Voltage (max.) 150V Temperature (max.) 75° C max DIRECT BURIAL RATED AWG Number of Conductors Stranding Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 14 2 41 Strand .165 x .365 44.1 1021 12 2 65 Strand .190 x .390 68.3 1019 10 2 104 Strand .214 x .422 99.0 1018 8 2 168 Strand .287 x .595 162.3 1017 66 | www.honeywellcable.com Genesis® Series Cable Irrigation/Tracer Construction Conductors Bare Copper Insulation Polyethylene Ratings/Listings Listings UL Tracer, Sunlight Resistant, Direct Burial Voltage (max.) 600V Temperature (max.) 75° C max DIRECT BURIAL RATED AWG Number of Conductors Stranding Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 18 1 Solid 0.133 10.0 1301 14 1 Solid 0.157 18.7 1303 12 1 Solid 0.174 27.4 1304 Genesis® Series Cable www.honeywellcable.com | 67 NOTES 68 | www.honeywellcable.com 1-800-222-0060 Genesis® Series Cable AUDIO/VIDEO CABLES Better cables, bolder sound Our wide range of application-specific cable options assure the best performance in high-end home theater installations, incorporating HDTV and digital video, audio, stereo, professional audio systems and home theater systems. AUDACIOUS® Premium Audio Cable Oxygen Free Copper High Strand Count: • WaveFLEX jacket (easy strip) • Oxygen-free copper (pure transmission) • High strand count (flexibility and more surface area) • Legend markings (channel, rooms and zones) • Countdown footage markings Home Theater Sound: • Twisted Bare Copper Conductors • Polypropylene Insulation • Countdown Footage Markings Direct Burial Audio Cable: • Oxygen-free copper (pure transmission) • High strand count (flexibility and more surface area) • Burial Applications CATV Video Cables: • Quad-shield or dual-shield construction Genesis® Series Cable www.honeywellcable.com | 69 Honeywell’s line of Audacious Sound Cable® continues to make noise – rounding out with a new 12-gauge option for longer runs. Get more sound with Audacious®, Honeywell’s best and highest quality line of audio cable. Using an oxygen-free copper conductor for optimal conductivity and a high strand count for maximum Hear the Difference purity, Audacious offers enhanced signal integrity and minimal distortion. Housed in our patent-pending WaveFlex™ ridged jacketing, cable is now easier than ever to strip, making for quicker installation and termination. Able to withstand the rigors of challenging applications, it delivers robust performance, time and time again. See for yourself – it’s like music to your ears. Insist on quality and innovation you can trust. Insist on Honeywell Audacious Sound Cable. For more information visit www.honeywellcable.com, or © 2016 Honeywell International. All rights reserved. 70 | www.honeywellcable.com contact your local ADI Representative. Genesis® Series Cable Audio/Video - Audacious® Premium Audio Construction Conductors Oxygen Free Bare Copper Insulation PVC Shielding N/A Jacket WaveFLEX® PVC Ratings/Listings Listings CMR/CL3R/FT4 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max AUDACIOUS PREMIUM AUDIO AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 16 2 65 Strand Unshielded 4.19 39.8 0.250 36.4 5473 16 4 65 Strand Unshielded 4.19 39.8 0.294 57.4 5474 14 2 105 Strand Unshielded 2.62 44.9 0.306 49.3 5475 14 4 105 Strand Unshielded 2.62 44.9 0.347 84.1 5476 12 2 105 Strand Unshielded 1.65 49.3 0.340 34.0 5477 Genesis® Series Cable www.honeywellcable.com | 71 Audio/Video - Audacious® Premium Audio Construction Conductors Oxygen Free Bare Copper Insulation Semi-Rigid PVC Shielding N/A Jacket PVC Ratings/Listings Listings CM/CL3 Direct Burial Sunlight Sun Res Resistant Voltage (max.) 300V Temperature (max.) 75° C max AUDACIOUS PREMIUM DIRECT BURIAL AUDIO AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 16 2 26 Strand Unshielded 4.19 35.2 0.274 45.3 5283 16 4 26 Strand Unshielded 4.19 35.2 0.350 76.3 5284 14 2 41 Strand Unshielded 2.62 40.0 0.320 61.1 5285 14 4 41 Strand Unshielded 2.62 40.0 0.365 104.5 5286 72 | www.honeywellcable.com Genesis® Series Cable Audio/Video - Home Theater Sound Construction Conductors Bare Copper Insulation Polypropylene Shielding N/A Jacket PVC Ratings/Listings Listings CM/CL3 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max HOME THEATER SOUND AWG Number of Conductors Stranding Shield DC Resistance (Ohms/1000') Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code 16 2 26 Strand Unshielded 4.19 22.5 0.180 22.7 5250 16 4 26 Strand Unshielded 4.19 22.5 0.210 42.7 5251 14 2 41 Strand Unshielded 2.62 24.6 0.224 35.6 5252 14 4 41 Strand Unshielded 2.62 24.6 0.260 65.7 5253 12 2 65 Strand Unshielded 1.65 26.4 0.264 52.7 5254 12 4 65 Strand Unshielded 1.65 26.4 0.312 100.0 5255 Genesis® Series Cable www.honeywellcable.com | 73 Audio/Video - Video Plenum Construction Coax Center Conductor Copper Clad Steel or Bare Copper Jacket Plenum PVC Ratings/Listings Listings CATVP/CL2P Voltage (max.) 300V Temperature (max.) 75° C max Riser Construction Coax Center Conductor Copper Clad Steel or Bare Copper Jacket PVC Ratings/Listings Listings CATVR/CMR/CL2R/FT4 Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max CATV COAX - PLENUM RATED DC Resistance (Ohms/1000') Velocity of Propagaton (%) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code AWG Style Shield 18 CCS RG6 Quad 60/40% 6.52 78% 16.5 0.264 41.0 5356 18 CCS RG6 Dual 60% 6.52 78% 16.5 0.236 36.0 5353 DC Resistance (Ohms/1000') Velocity of Propagaton (%) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code CATV COAX - RISER RATED AWG Style Shield 18 CCS RG6 Quad 60/40% 6.52 78% 16.5 0.298 30.0 5307 18 CCS RG6 Dual 60% 6.52 78% 16.5 0.275 30.0 5303 18 BC RG6 Dual 60% 6.52 78% 15.5 0.275 30.0 5304 74 | www.honeywellcable.com Genesis® Series Cable Audio/Video - Video General Purpose Construction Coax Center Conductor Copper Clad Steel or Bare Copper Jacket PVC Ratings/Listings Listings CATV/CL2P Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max Water Resistant Construction Coax Center Conductor Copper Clad Steel or Bare Copper Jacket Polyethylene Ratings/Listings Listings Sunlight Resistant Voltage (max.) 300V Temperature (max.) 75° C max CATV COAX - GENERAL PURPOSE RATED Shield DC Resistance (Ohms/1000') Velocity of Propagaton (%) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code RG11 Dual 60% 2.57 78% 16.5 0.400 62.0 5018 RG6 Quad 60/40% 6.52 78% 16.5 0.295 33.0 5007 2 x RG6 Quad 60/40% 6.52 78% 16.5 .298 x .605 70.0 5008 AWG Style 14 CCS 18 CCS 18 CCS 18 BC RG6 Quad 60/40% 6.52 78% 16.5 0.298 35.0 5027 18 CCS RG6 Dual 60% 6.52 78% 16.5 0.275 29.0 5003 20 CCS RG59 Dual 40% 11.1 78% 17.3 0.244 25.0 5006 DC Resistance (Ohms/1000') Velocity of Propagaton (%) Nominal Capacitance (pF/ft.) Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code CATV COAX - WATER RESISTANT RATED AWG Style Shield 18 CCS RG6 Quad 60/40% 6.52 78% 16.5 0.298 32.0 5106 18 CCS RG6 Dual 60% 6.52 78% 16.5 0.275 32.0 5105 Genesis® Series Cable www.honeywellcable.com | 75 NOTES 76 | www.honeywellcable.com 1-800-222-0060 Genesis® Series Cable MULTIMEDIA CABLES Multipurpose, saving time and money Honeywell Cable offers multimedia cables to support voice, video and data in a single cable. Multimedia cables are composite constructions designed to minimize the number of cable pulls, reduce installation cost and shorten the time required for the pre-wiring of residential systems. Features: • Multiple constructions available • Cables are performance tested after bundling to assure quality • Reduces labor time and installation cost • UL/ETL listed and verified • 100% guaranteed • Zone and room markings available on jacketed multimedia cables Article 725: Class 1, Class 2 and Class 3 remote-control, signaling and power limited circuits that are not an integral part of a device or appliance. The scope of this article may include systems such as burglar alarm, access control, sound, nurse call, intercom circuits, some computer network systems, some control circuits for lighting dimmer systems, and some low-voltage control circuits that originate from listed computer equipment. General Purpose Cable: Type CM, CL3 Genesis® Series Cable www.honeywellcable.com | 77 Multimedia Honeywell Multimedia Cable Specifications: • General Purpose Rated • CM/CL3, Sunlight Resistant Listed • Rated to 75° C max • Cat cables sweep tested to 350 MHz (Cat 5e guaranteed up to 100MHz and Cat 6 Plus guaranteed up to 250MHz), exceeding the TIA/EIA-568-C.2 standard, guaranteeing the non-degraded capability of network throughput 100Mbps (Cat 5e) /1Gbps (Cat 6 Plus) at 100m – ideal for all residential multimedia, voice, video, and data applications • Coax component: braided and foiled shielding layer, sweep tested to 3GHz, ideal for HDTV, DBS, CATV, SVHS, CCTV and cable modem applications JACKETED MULTIMEDIA Description Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code (2) RG6 CCS Quad-Shield Coax + (2) 24/4 pair Cat 5e 0.670 115.2 5050 (2) RG6 CCS Quad-Shield Coax + (2) 23/4 pair Cat 6 Plus 0.650 154.0 5065 Description Nominal Outer Diameter (inches) Average Weight (Pounds/1000') Product Code RG6 CCS Quad-Shield Coax + 24/4 pair Cat 5e .298 x .523 40.8 5066 RG6 CCS Dual-Shield 60% Coax + 24/4 pair Cat 5e .275 x .520 39.9 5067 DUAL ZIP 78 | www.honeywellcable.com Genesis® Series Cable TECHNICAL DATA, TOOLS & RESOURCES The NEC is a highly regarded handbook resource and considered the most comprehensive document on electrical safety. The NEC was developed by a large cross-section of representatives from the electrical industry (electricians, engineers, code enforcers, researchers, testers, insurers, etc.) The NEC explains current code requirements and discusses pertinent code changes. Specific technical language is contained in the handbook with complete information on: • Code Requirements and Application • Code Intent • Code Restrictions • Code Interpretations In addition, historical trends are examined, and tables and illustrations are provided. The NEC is divided into sections containing articles on specific electrical subject areas. Community codes for installations are usually based on information or requirements in the NEC. For convenience, Honeywell’s Genesis® Series Cable catalog has identified pertinent NEC articles and scope of article for each cable group as well as provided useful information to help with ordering appropriate cable. Genesis® Series Cable www.honeywellcable.com | 79 Cable Substitution Hierarchy (Based on National Electric Code) Article 820 Article 800 Article 760 Article 725 Plenum CATVP CMP CL3P CL2P CL3R CL2R CL3 CL2 CL3X CL2X FPLP Riser CATVR CMR FPLR General Purpose CATV CM FPL Dwellings CATVX CMX Article 820: Community Antenna Television and Radio Distribution Systems Article 800: Communication Circuits Article 760: Fire Alarm Systems Article 725: Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits 80 | www.honeywellcable.com Genesis® Series Cable ANSI/TIA/EIA-568C.2: Commercial Building Telecommunications Cabling Standard The following tables list attenuation and near-end crosstalk (NEXT) specifications from ANSI/TIA/EIA-568C.2 for Category 3, Category 5 and 6 unshielded twisted pair (UTP) cables. TABLE 1: HORIZONTAL UTP CABLE ATTENUATION DB/100 m (DB/1000 ft.) Frequency (MHz) Category 3 (dB) Category 5e (dB) Category 6 (dB) 0.772 2.2 n/s n/s Category 6A (dB) n/s 1.00 2.6 2.0 2.0 2.1 4.00 5.6 4.1 3.8 3.8 8.00 8.5 5.8 5.3 5.3 10.00 9.7 6.5 6.0 5.9 16.00 13.1 8.2 7.6 7.5 20.00 - 9.3 8.5 8.4 25.00 - 10.4 9.5 9.4 31.25 - 11.7 10.7 10.5 62.50 - 17.0 15.4 15.0 100.00 - 22.0 19.8 19.1 200.00 - - 29.0 27.6 250.00 - - 32.8 31.1 300.00 - - - 34.3 400.00 - - - 40.1 500.00 - - - 45.3 Category 6A (dB) TABLE 2: HORIZONTAL UTP CABLE ATTENUATION DB/100 m (DB/1000 ft.) Frequency (MHz) Category 3 (dB) Category 5e (dB) Category 6 (dB) 0.772 43.0 n/s n/s n/s 1.00 41.3 65.3 74.3 74.3 4.00 32.3 56.3 65.3 65.3 8.00 27.8 51.8 60.8 60.8 10.00 26.3 50.3 59.3 59.3 16.00 23.2 47.2 56.2 56.2 20.00 - 45.8 54.8 54.8 25.00 - 44.3 53.3 53.3 31.25 - 42.9 51.9 51.9 62.50 - 38.4 47.4 47.4 100.00 - 35.3 44.3 44.3 200.00 - - 39.8 39.8 250.00 - - 38.3 38.3 300.00 - - - 37.1 400.00 - - - 35.3 500.00 - - - 33.8 Genesis® Series Cable www.honeywellcable.com | 81 Voltage Drop and Recommended Footage Chart Approximate Voltage Drop at 68° F 14 26AWG 24AWG 22AWG Voltage Drop/Amps 12 10 20AWG 8 6 18AWG 16AWG 4 2 300 0 0 50 100 150 200 350 250 Feet Note: The chart above shows the approximate values for the AC resistive component of the circuit impedance. Example: What is the voltage drop for an 18 AWG 2/C carrying 3 amps over a distance of 100 feet? Voltage-drop = voltage-drop/amp x amp = 1.2 x 3 = 3.6 Volts Recommended Footage/AWG Audio Cable MAXIMUM CABLE LENGTH (FT.) Acceptable Loss (%) 4 Ohm Speaker 8 Ohm Speaker 10% 20% 50% 10% 20% 50% 12 AWG 250 500 50 500 1000 2500 14 AWG 150 300 750 300 600 1500 16 AWG 95 190 475 190 380 950 82 | www.honeywellcable.com Genesis® Series Cable General Information CCTV TRANSMISSION DISTANCES Style Typical Run Length RG6/U Up to 1500 ft. RG59/U BC Braid Up to 750 ft. RG59/U CCA Braid Up to 600 ft. 75 Ohm Mini Coax Up to 375 ft. PULLING TENSIONS Under the stress of approximately 15,000 pounds per square inch, annealed copper will begin to permanently stretch. The table below lists the absolute maximum recommended pulling tensions for conductor sizes. For multiple conductor cable, multiply the appropriate value by the total number of conductors. These pulling tensions must be equally distributed among the conductors. THESE LIMITS MUST NEVER BE EXCEEDED EVEN MOMENTARILY. DO NOT JERK THE CABLE. The electronic characteristics of a cable may change due to excessive tension and crushing. PULLING TENSIONS Recommended Pulling Tension (75% of Max.) (lbs.) Gauge (AWG) Max. Pulling Tension (lbs.) 24 4 3.0 22 7 5.25 Genesis® Series Cable 20 12 9.0 18 19 14.25 16 30 22.5 14 48 36.0 12 77 57.75 www.honeywellcable.com | 83 Conduit Capacity Chart Conduit Trade Size (in.) 0.5 0.75 1 1.25 1.5 2 2.5 3 3.5 4 I.D. (IN.) 0.622 0.824 1.049 1.38 1.61 2.067 2.731 3.356 3.834 4.334 Cable O.D. (in.) Cable Area (in.)* 0.100 0.008 15 27 44 76 104 171 298 450 588 751 0.125 0.012 10 17 28 49 66 109 191 288 376 481 Numbers Listed Below are Based on 40% Fill Rate for Three or More Cables 0.150 0.018 7 12 20 34 46 76 133 200 261 334 0.175 0.024 5 9 14 25 34 56 97 147 192 245 0.200 0.031 4 7 11 19 26 43 75 113 147 188 0.225 0.040 3 5 9 15 20 34 59 89 116 148 120 0.250 0.049 2 4 7 12 17 27 48 72 94 0.275 0.059 2 4 6 10 14 23 39 60 78 99 0.300 0.071 2 3 5 8 12 19 33 50 65 83 0.325 0.083 1 3 4 7 10 16 28 43 56 71 0.350 0.096 1 2 4 6 8 14 24 37 48 61 0.375 0.110 1 2 3 5 7 12 21 32 42 53 0.400 0.126 1 2 3 5 6 11 19 28 37 47 0.425 0.142 1 2 2 4 6 9 17 25 33 42 0.450 0.159 1 1 2 4 5 8 15 22 29 37 0.475 0.177 1 1 2 3 5 8 13 20 26 33 0.500 0.196 1 1 2 3 4 7 12 18 24 30 0.525 0.216 1 1 2 3 4 6 11 16 21 27 0.550 0.237 1 1 1 3 3 6 10 15 19 25 0.575 0.260 0 1 1 2 3 5 9 14 18 23 0.600 0.283 0 1 1 2 3 5 8 13 16 21 0.625 0.307 0 1 1 2 3 4 8 12 15 19 0.650 0.332 0 1 1 2 2 4 7 11 14 18 0.675 0.358 0 1 1 2 2 4 7 10 13 16 0.700 0.385 0 1 1 2 2 3 6 9 12 15 0.725 0.413 0 1 1 1 2 3 6 9 11 14 0.750 0.442 0 0 1 1 2 3 5 8 10 13 0.775 0.471 0 0 1 1 2 3 5 7 10 13 0.800 0.502 0 0 1 1 2 3 5 7 9 12 0.825 0.534 0 0 1 1 2 3 4 7 9 11 0.850 0.567 0 0 1 1 1 2 4 6 8 10 10 0.875 0.601 0 0 1 1 1 2 4 6 8 0.900 0.636 0 0 1 1 1 2 4 6 7 9 0.925 0.672 0 0 1 1 1 2 3 5 7 9 0.950 0.708 0 0 0 1 1 2 3 5 7 8 0.975 0.746 0 0 0 1 1 2 3 5 6 8 1.000 0.785 0 0 0 1 1 2 3 5 6 8 1.025 0.825 0 0 0 1 1 2 3 4 6 7 1.050 0.865 0 0 0 1 1 2 3 4 5 7 1.075 0.907 0 0 0 1 1 1 3 4 5 7 * Use as a guide when attempting to estimate conduit fill. Consult the NEC for specific information regarding conduit fill. 84 | www.honeywellcable.com Genesis® Series Cable Glossary of Abbreviations AI Aluminum BC Bare Copper CATV Community Antenna Television CCA Copper Covered Aluminum/Copper Clad Aluminum CCS Copper Covered Steel/Copper Clad Steel CCTV Closed Circuit Television EMI Eletromagnetic Interference FEP Fluorinated Ethylene Propylene HDTV High Definition Television LLDPE Linear Low-Density Polyethylene LSPVC Low-Smoke Polyvinyl Chloride MATV Master Antenna Television OFBC Oxygen-Free Bare Copper PE Polyethylene PP Polypropylene PVC Polyvinyl Chloride RFI Radio Frequency Interference SRPVC Semi-Rigid Polyvinyl Chloride TC Tinned Copper TPE Thermoplastic Elastomer UTP Unshielded Twisted Pair Genesis® Series Cable www.honeywellcable.com | 85 NOTES 86 | www.honeywellcable.com 1-800-222-0060 Genesis® Series Cable INDEX Index by Honeywell Genesis® Cable Part Number 1002.............................................24 1003.............................................24 1004.............................................24 1017.............................................66 1018.............................................66 1019.............................................66 1021.............................................66 1031.............................................40 1032.............................................40 1051.............................................24 1052.............................................24 1057.............................................24 1068.............................................60 1070.............................................60 1073.............................................60 1075.............................................60 1101.............................................22 1102.............................................22 1103.............................................22 1104.............................................22 1106.............................................22 1107.............................................22 1108.............................................22 1109.............................................22 1111.............................................22 1112.............................................22 1113.............................................22 1118.....................................22, 60 1119.............................................22 1120.............................................22 1121.............................................22 1123.............................................22 1125.............................................22 1126.............................................22 1127.............................................22 1129.............................................22 1130.............................................22 1131.............................................22 1133.............................................19 1138.............................................22 1140.............................................22 1170.............................................19 1202.............................................23 1204.............................................23 1206.............................................23 1207.............................................23 1208.............................................23 1209.............................................23 1212.............................................23 1214.............................................23 1215.....................................23, 60 1216.............................................23 1217.............................................23 1218.............................................23 1221.....................................23, 60 1222.............................................23 Genesis® Series Cable 1223.............................................23 1228.....................................23, 60 1229.............................................23 1244.............................................64 1250.............................................24 1260.............................................64 1264.............................................24 1287.............................................64 1301.............................................67 1303.............................................67 1304.............................................67 2101.............................................20 2102.............................................20 2103.............................................20 2104.............................................20 2106.............................................20 2109.............................................20 2113.............................................20 2114.............................................20 2115.............................................20 2116.............................................20 2117.............................................20 2118.............................................20 2119.............................................20 2121.............................................20 2122.............................................20 2123.............................................20 2124.............................................20 2125.............................................20 2195.............................................27 2196.............................................27 2202.............................................21 2203.............................................21 2204.............................................21 2206.............................................21 2207.............................................21 2208.............................................21 2209.............................................21 2214.............................................21 2215.............................................21 2216.............................................21 2217.............................................21 2218.............................................21 2219.............................................21 2221.............................................21 2222.............................................21 2223.............................................21 2224.............................................21 2295.............................................27 2296.............................................27 3101.............................................16 3102.............................................16 3103.............................................16 3104.............................................16 3106.............................................16 3107.............................................16 3108.............................................16 3109.............................................16 3114.............................................16 3115.............................................16 3116.............................................16 3117.............................................16 3118.............................................16 3119.............................................16 3121.............................................16 3122.............................................16 3123.............................................16 3124.............................................16 3125.............................................16 3126.............................................16 3127.............................................16 3129.............................................16 3134.............................................16 3195.............................................26 3196.............................................26 3201.............................................17 3202.............................................17 3203.............................................17 3204.............................................17 3206.............................................17 3207.............................................17 3208.............................................17 3209.............................................17 3214.............................................17 3215.............................................17 3216.............................................17 3217.............................................17 3218.............................................17 3221.............................................17 3222.............................................17 3223.............................................17 3224.............................................17 3226.............................................17 3227.............................................17 3247.............................................18 3248.............................................18 3251.............................................62 3252.............................................63 3253.............................................63 3254.............................................63 3255.............................................63 3276.............................................17 3281.............................................18 3295.............................................26 3296.............................................26 3319.............................................62 3320.............................................62 3322.............................................62 3323.............................................62 3324.............................................62 3328.............................................62 4006.............................................52 1002-4320 4011.............................................52 4012.............................................52 4015.............................................52 4016.............................................52 4017.............................................52 4018.............................................52 4020.............................................52 4021.............................................52 4022.............................................52 4023.............................................52 4024.............................................52 4026.............................................52 4101.............................................48 4102.............................................48 4106.............................................48 4107.............................................48 4108.............................................48 4109.............................................48 4110.............................................48 4111.............................................48 4112.............................................48 4113.............................................48 4114.............................................48 4115.............................................48 4151.............................................51 4152.............................................51 4153.............................................51 4154.............................................51 4156.............................................51 4157.............................................51 4158.............................................51 4159.............................................51 4202.............................................49 4203.............................................49 4204.............................................49 4205.............................................49 4206.............................................49 4208.............................................49 4290.............................................50 4291.............................................50 4292.............................................50 4293.............................................50 4294.............................................50 4295.............................................50 4296.............................................50 4301.............................................46 4306.............................................46 4307.............................................46 4308.............................................46 4310.............................................46 4311.............................................46 4312.............................................46 4313.............................................46 4314.............................................46 4315.............................................46 4320.............................................46 www.honeywellcable.com | 87 INDEX Index by Honeywell Genesis® Cable Part Number 4402.............................................47 4403.............................................47 4404.............................................47 4405.............................................47 4406.............................................47 4407.............................................47 4408.............................................47 4409.............................................47 4410.............................................47 4422.............................................45 4423.............................................45 4424.............................................45 4431.............................................46 4432.............................................46 4441.............................................47 4442.............................................47 4502.............................................42 4506.............................................42 4507.............................................42 4508.............................................42 4511.............................................42 4512.............................................42 4513.............................................42 4514.............................................42 4515.............................................42 4521.............................................42 4522.............................................42 4524.............................................42 4525.............................................42 4602.............................................43 4603.............................................43 4604.............................................43 4606.............................................43 4607.............................................43 4608.............................................43 4609.............................................43 4610.............................................43 4612.............................................43 4614.............................................43 4652.............................................63 4701.............................................58 4702.............................................58 4703.............................................58 4704.............................................58 4705.............................................58 4706.............................................58 4707.............................................58 4710.............................................58 4711.............................................58 4712.............................................58 4713.............................................58 4714.............................................58 4715.............................................58 4716.............................................58 4717.............................................58 4718.............................................58 88 | www.honeywellcable.com 4719.............................................58 4760.............................................59 4761.............................................59 4762.............................................59 4763.............................................59 4764.............................................59 4766.............................................59 4768.............................................59 5001.............................................32 5002.............................................32 5003.............................................75 5006.............................................75 5007.............................................75 5008.............................................75 5013.............................................32 5018.............................................75 5020.............................................32 5027.............................................75 5031.............................................40 5032.............................................40 5050.............................................78 5065.............................................78 5066.............................................78 5067.............................................78 5078.............................................38 5088.............................................38 5090.............................................39 5092.............................................36 5102.............................................36 5103.............................................32 5104.............................................32 5105.............................................75 5106.............................................75 5119.............................................32 5178.............................................38 5192.............................................36 5193.............................................35 5250.............................................73 5251.............................................73 5252.............................................73 5253.............................................73 5254.............................................73 5255.............................................73 5283.............................................72 5284.............................................72 5285.............................................72 5286.............................................72 5301.............................................31 5302.............................................31 5303.............................................74 5304.............................................74 5307.............................................74 5351.............................................31 5352.............................................31 5353.............................................74 5355.............................................31 5356.............................................74 5388.............................................38 5392.............................................36 5393.............................................35 5473.............................................71 5474.............................................71 5475.............................................71 5476.............................................71 5477.............................................71 5501.............................................53 5502.............................................53 5503.............................................53 5504.............................................53 5505.............................................53 5506.............................................53 5550.............................................53 5552.............................................53 5553.............................................53 5554.............................................53 5555.............................................53 6330.............................................39 6360.............................................37 6361.............................................37 6501.............................................32 6508.............................................32 6713.............................................57 6714.............................................57 6716.............................................57 6718.............................................57 4402-6718 Genesis® Series Cable Responsive, reliable, world-class service that works with you. Backed by a Fortune 100 company that sets the standard across numerous industries, our robust support system is second to none. It has enabled us at Honeywell Cable to build our entire organization around creating the best, hassle-free experience for our customers. It drives everything we do, including our: Thousands of locations across the Toll-free, LIVE customer Free freight with orders of security, low-voltage, electrical and service and sales support at: $1,500 or more. By stocking up for HVAC distribution channels where our 800-222-0060. Get immediate, upcoming jobs, we help you save Honeywell Genesis® Series cable is responsive assistance when you time and money over the long haul. readily available for quick delivery or need it! pick up. ReadySHIP – over 100 current Cable for That! app – Provides an Robust, industry-leading warranties products that ship same day (for easy-to-use and accessible guide – Backing up our commitment to orders placed prior to 3:00 p.m., after that helps you choose the right quality, we have gone to great lengths to 3:00 p.m. ships next day) – list cable for your application – go to our offer standard or extended agreements available on our website or by calling website and use your mobile device to on our entire range of customer service. download the app that’s right for you. innovative products. Please visit www.honeywellcable.com for more information, including a detailed cable catalog. Cable engineered by the equipment manufacturer. At Honeywell Cable, we strive to be the most trusted, go-to brand for low-voltage cable across a wide range of applications. By providing quality wiring products and responsive, reliable world-class service, our mission is to enable your success every day. Security, fire, network, HVAC, audio/video, control … whatever your application, “We’ve got a Cable for That!” Visit www.honeywellcable.com to see our full product listing of low-voltage wire and cable, including: • Security • Fire • IP – Network • Thermostat • Sound • And much more! For more information: www.honeywellcable.com For mobile devices: m.honeywellcable.com Honeywell Cable 7701 95th Street Pleasant Prairie, WI 53158 800.222.0060 www.honeywell.com L/CBLPRD16CT/D 12/16 © 2016 Honeywell International Inc.