23A-12V TECHNICAL SPECIFICATION DRAFTED BY: CHECKED BY: APPROVED BY:
CLIENT ADMITED SIGN:
SHENZHEN XELLEX BATTERY & POWER SUPPLY TECH. CO., LTD
HONGKONG XELLEX BATTERY CO., LTD
6/F, Jiayu Bldg, Dong’er Xiang 15#, Gongyuan Road, 22 Industry Zone, Bao’an District, Shenzhen, PRC.
Flat A, 12/F., Wing Sing Commercial Centre, 12-16 Wing Lok Street, Hong Kong
TEL:0086-755-27664401 27664402 27664403 FAX: 0086-755-27806777 27664407 Website: www.xellex-battery.com Email:
[email protected]
TEL: 00852-28507117 FAX: 00852-25819986 Website: xellex.en.alibaba.com Email:
[email protected]
The Technical Specifications hereinafter is only applicable to the Hg & Cd Free Alkaline Zinc Manganese Dioxide 23A-12V type battery, which was provided by Xellex Battery Co., Ltd. All the practical technical data, which were used to describe Battery Performance involved in the Specifications are obtained from the relevant experiments to the products of Xellex. Rights reserved to take relevant rectifications or modifications to the structure and performance of the products without prior notice. Page
1
of
5
Spec. NO.:XL-23A-12V
Edition:Rev.00
Date:2005-08-28
1.Scope The Specifications is solely applicable to the “Xellex” Hg & Cd Free Alkaline Zinc Manganese Dioxide Battery---23A-12V. 1.1Designations Xellex :23A-12V
IEC :
JIS :
ANSI :
Other:23A , V23GA
1.2 Reference Document IEC 60086-1(2000)
--- Primary Batteries - General
IEC 60086-2(2000)
--- Primary Batteries – Specification Sheets
2. Chemical System Alkaline Electrolyte--- Zinc-Manganese Dioxide Battery (0%Hg and 0%Cd added)
3. Dimensions Diameter: 10.1±0.2 mm
Height: 28.0±0.5 mm
4.Nominal Voltage:12 Volts 5.Average Weight:8.2 g 6. Nominal Capacity 41mAh (20KΩ continuous discharge,Temp.:20±2℃,CDV
:7.2 Volts)
7. Electrical Performance (Conditions:100Ω±0.5% load resistance, Measuring time 0.3 Seconds, Temperature at 20±2℃, Tested within 30 Days after delivery)
New Battery After 12 Mths Shelf Time at room Temp
Off-load
On-load
Voltage(V)
Voltage(V)
≥12.2
≥7.0
≥12.0
≥6.8
Acceptance Standard
MIL-STD105E,Class II,Double Sampling,AQL=0.4
*The Hair Spring Ampere Meter with ±0.5% Accuracy (0.5 Level) shall be used.
8.Service Output (Conditions:Test Temp.20±2℃ ,Relative Humidity: 45%-75% Test within 30 Days after delivery)
Page
2
of
5
Spec. NO.:XL-23A-12V
Edition:Rev.00
Date:2005-08-28 Average Minimum Discharge
Discharge Condition
Time
Test Standards
Cut-off Discharge
Daily Discharge
Discharge
Load
Time
Voltage
After 12 Mths New Battery
room Temp.
(V) IEC Standard
20KΩ
24 Hours
7.2
Shelf Time at
≥87Hours
≥80Hours
Acceptance Criteria:9 batteries shall be tested for each discharging standard, the Average Discharging Time should be equal to or above the Average Minimum Discharging Time required. Moreover, the total amount of the batteries whose Average Discharging Time is less than 80% of the time required shall not exceed 1, Thus, the ADT of the batteries can be recognized accorded with the requirements
9.Electrolyte Leakage Proof Characteristics
Item
Condition
Period
Characteristic
Acceptance
s
Standard
There shall be no 20KΩ Over-discharge Characteristics
continuous
deformation
discharge at Temp.: 20 ± 2 ℃ Relative
exceeding the 48 Hours
specified
Humidity : 65 ±
dimensions,
15%RH
nor leakage recognized by human eye
10.Safety Characteristics
Page
3
of
5
N=30,Ac=0,Re=1
Spec. NO.:XL-23A-12V
Item
Edition:Rev.00
Condition
Period
Date:2005-08-28
Characteristics
Acceptance Standard
Temp: 20±2℃ Short Circuit Characteristics
Relative Humidity: 60±15%
There shall be
Directly connect the Positive
24 Hours
& Negative Terminals with a
no
explosion
N=9,Ac=0,Re=1
of battery
wire
11.Marking
The following markings will be printed, stamped or impressed on the body of
the battery: (1)Designation :23A-12V (2)Manufacturer’s name, abbreviation or brand:XELLEX (3)Nominal Voltage :12V (4)Polarity :“+”, “-” (5)Warning: Battery may explode or leak if recharged or disposed of in fire. (6)Expiry Date(Guarantee Period):The Date which shows on the labels of the finished product is used to indicate the Quality Assurance Period before it is used.
12.Caution for Use (1)Since the battery is not manufactured for recharging, there are risks of electrolyte leakage or causing damage to the device if the battery is charged. (2)The battery shall be installed with its “+” and “-”in the right position. (3)Short-connecting, heating, disposing of into fire and disassembling the battery are prohibited.
13.Shelf Life: 12 months after delivery under proper storage conditions.
14.Discharging Curves ⑴20KΩ,24 Hours/Day, E.P.V: 6.0V Continuous Discharging Curves(Figure 1)
15.Battery Dimensions & Structure(Figure 2)
Page
4
of
5
Spec. NO.:XL-23A-12V
Edition:Rev.00
Date:2005-08-28
Figure 1:
(v) 13.0 12.0 11.0 10.0 9.00 8.00 7.00 6.00 5.00
0
16
32
48
Figure 2:
Page
5
of 5
64
80 96 HOURS OF SERVICE