Transcript
24" (61 cm) and 27" (69 cm) Gas Washer/Dryer PRODUCT MODEL NUMBERS
WGT4027E Dimensions/Clearances - 24" (61 cm) Front View
Side View 35 7/8" (911 mm)
23 7/8" (606 mm)
70 3/4" (1797 mm)
20 1/2" (521 mm)
653/4" (1670 mm)
70 3/4" (1797 mm)
30 3/4" (781 mm)
1" (25 mm)
37" (940 mm)
26 7/8" (683 mm)
1" (25 mm)
Back View 23 7/8" (606 mm)
111/2" (292 mm) 70 3/4" (1797 mm) 14" (356 mm) 43 1/2" (1105 mm)
34 1/4" (870 mm)
27 1/2" 26" (699 mm) (660 mm)
1" (25 mm) W10761051A 05/2015
Dimensions/Clearances - 27" (69 cm) Front View
Side View
1 /4" 27.5 (692 mm)
58 7/8" (1495 mm)
26" (660 mm)
3 /4" 71.5 (822 mm)
653/4" (1670 mm)
713/4" (1822 mm)
321/8" (816 mm)
34" (864 mm)
1" (25 mm)
32" (813 mm)
Back View 271/4" (692 mm)
11" (279 mm)
713/4" (1822 mm) 14" (356 mm)
411/4" (1,048 mm) 351/4" (895 mm)
261/2" 25" (673 mm) (635 mm)
1" (25 mm)
2
1" (25 mm)
Clearances Side Clearances (recommended/minimum)
Front/Back/Top (recommended/minimum)
Recessed area or closet installation 12" (305 mm)
48 in.2 (310 cm2)
Front View
3" (76 mm)
Closet door
3" (76 mm) 24 in.2 (155 cm2) 1"/0" (25 mm/0 mm)
1"/0" (25 mm/0 mm)
1" (25 mm) (Closet)
5" (127 mm)
GAS SUPPLY REQUIREMENTS Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be ½" IPS. When acceptable to the gas supplier and local codes, 3⁄8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
ELECTRICAL REQUIREMENTS A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended. The “Vent System Chart” provides venting requirements that will help achieve best drying performance.
VENTING REQUIREMENTS Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust. Recommended Styles:
Louvered hood
Acceptable Style:
Box hood
Angled hood
Vent System Chart, 24" Models Number of 90° turns or elbows
Type of vent
Box/louvered hoods
Angled hoods
0
Rigid metal
43 ft. (13.1 m)
36 ft. (11.0 m)
1
Rigid metal
33 ft. (10.1 m)
26 ft. (7.9 m)
2
Rigid metal
23 ft. (7.0 m)
16 ft. (4.9 m)
Vent System Chart, 27" Models Number of 90° turns or elbows
Type of vent
Box/louvered hoods
Angled hoods
0
Rigid metal
37 ft. (11.3 m)
35 ft. (10.7 m)
1
Rigid metal
32 ft. (9.7 m)
27 ft. (8.2 m)
2
Rigid metal
23 ft. (7.0 m)
19 ft. (5.8 m)
NOTE: Side exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.
3
DRAIN SYSTEM Drain system can be installed using a floor drain, wall standpipe, floor standpipe, or laundry tub. Select method you need.
Floor standpipe drain system Minimum diameter for a standpipe drain: 2" (51 mm). Minimum carry-away capacity: 17 gal. (64 L) per minute. Top of standpipe must be at least 39" (990 mm) high; install no higher than 96" (2.4 m) from bottom of washer/dryer. If you must install higher than 96" (2.4 m), you will need a sump pump system.
Floor drain system Floor drain system requires a Siphon Break Kit (Part Number 285834), 2 Connector Kits (Part Number 285385), and an Extension Drain Hose (Part Number 285863) that may be purchased separately. See “Use and Care Guide” for ordering details. Minimum siphon break: 28" (710 mm) from bottom of washer/dryer. (Additional hoses may be needed.)
Laundry tub drain system Wall standpipe drain system See requirements for floor standpipe drain system.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Minimum capacity: 20 gal. (76 L). Top of laundry tub must be at least 39" (990 mm) above floor; install no higher than 96" (2.4 m) from bottom of washer/dryer. IMPORTANT: To avoid siphoning, no more than 4.5" (113 mm) of drain hose should be inside standpipe or below the top of wash tub. Secure drain hose with shipping strap.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.