Preview only show first 10 pages with watermark. For full document please download

24skt Din Sh1b

   EMBED


Share

Transcript

Relays & Sockets RH Series Sockets (for Blade Terminal Models) Standard DIN Rail Mount 1 Finger-safe DIN Rail Mount 1 Through Panel Mount PCB Mount RH1B SH1B-05 SH1B-O5C SH1B-51 SH1B-62 RH2B SH2B-05 SH2B-05C SH2B-51 SH2B-62 RH3B SH3B-05 SH3B-05C SH3B-51 SH3B-62 RH4B SH4B-05 SH4B-05C SH4B-51 SH4B-62 Switches & Pilot Lights Relays 1. DIN Rail mount socket comes with two horseshoe clips. Do not use unless you plan to insert pullover wire spring. Replacement horseshoe clip part number is Y778-011. Appearance Description Pullover Wire Spring For DIN Mount Socket RH1B SY2S-02F1 2 RH2B SY4S-02F1 2 RH3B SH3B-05F1 2 RH4B SH4B-02F1 2 RH1B, RH2B, RH3B, RH4B SFA-202 3 For Through Panel & PCB Mount Socket Min Order Qty SY4S-51F1 2. Must use horseshoe clip when mounting in DIN mount socket. Replacement horseshoe clip part number is Y778-011. 3. Two required per relay. 10 Relays & Sockets Leaf Spring (side latch) Relay Display Lights Hold Down Springs & Clips SFA-302 3 20 Leaf Spring (top latch) RH1B, RH2B, RH3B, RH4B SFA-101 3 SFA-301 3 AC Coil Ratings Rated Current (mA) ±15% at 20°C Voltage (V) AC 50Hz SPDT DPDT 3PDT Coil Resistance (Ω) ±10% at 20°C AC 60Hz 4PDT SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT Operation Characteristics (against rated values at 20ºC) 4PDT 240 330 387 150 200 280 330 330 9.4 6.4 5.4 86 121 165 196 75 100 140 165 165 39.3 25.3 21.2 24 42 60.5 81 98 37 50 70 83 83 153 103 84.5 110 9.6 — 18.1 21.6 8.4 — 15.5 18.2 18.2 — 2,200 1,800 110-120 — 9.410.8 — — — 8.0-9.2 — — — — — — 120 8.6 — 16.4 19.5 7.5 — 14.2 16.5 16.5 — 10,800 7,360 9.1 9.1 — 10,800 7,360 — 18,820 — — 8.3 — 12,100 9,120 220 4.7 — 8.8 10.7 4.1 — 7.7 220-240 — 4.7-5.4 — — — 4.0-4.6 — 240 4.9 — 8.2 9.8 4.3 — 7.1 8.3 Dropout Voltage 110% 80% maximum 30% minimum Terminal Blocks 170 Pickup Voltage Timers 6 12 Max. Continuous Applied Voltage DC Coil Ratings Voltage (V) Coil Resistance (Ω) ±10% at 20°C Rated Current (mA) ±15% at 20°C SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT Operation Characteristics (against rated values at 20ºC) 4PDT 128 150 240 250 47 40 25 24 64 75 120 125 188 160 100 96 24 32 36.9 60 62 750 650 400 388 48 18 18.5 30 31 2,660 2,600 1,600 1,550 100-110 — 8.2-9.0 — — — 12,250 — — 110 8 — 12.8 15 13,800 — 8,600 7,340 USA: 800-262-IDEC Pickup Voltage Dropout Voltage Circuit Breakers 6 12 Max. Continuous Applied Voltage Standard coil voltages are in BOLD. 110% 80% maximum Canada: 888-317-IDEC 10% minimum 727 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series Dimensions con’t (mm) Switches & Pilot Lights RH1V2-U/RH1V2-UD RH2V2-U/RH2V2-UL/RH2V2-UD 8-ø2.4 holes 4.7 0.5 3-ø2.4 holes 7.25 0.5 14 12 14 35.6 max. 4.4 7.8 10 RH3V2-U/RH3V2-UL/RH3V2-D 21 4.6 14.2 RH4V2-U/RH4V2-UL/RH4V2-UD 10 10 14-ø2.4 holes 2 4.7 10 13.15 4 7 8 10 11 12 14 0.5 4.6 7.8 3 6 9 13 7.25 31 2 5 7.25 14 13 27.5 1 0.5 11 27.5 8 10 7.8 4 6 9 0.5 35.6 max. 2 5 13.15 2 0.5 1 Display Lights 30 11-ø2.4 holes 4.7 4.6 8 9 2 35.6 max. 4 5 13 27.5 1 5 14 12.5 0.5 9 6.6 27.5 5 13 13.15 1 0.5 7.15 2 4.7 2 1.5 2-ø2 holes 0.5 41 35.6 max. 4.6 Relays & Sockets Standard DIN Rail Mount Sockets SH1B-05 SH2B-05 31.5 22 DIN Rail (BNDN) 18 M3.5 Terminal Screw Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 47 (Top View) ø3.2 min. ø3.6 min. 7.9 max. 5.9 max. SH3B-05 14 13 12 14.5 9 30 25 (Top View) 7.9 max. ø3.6 min. 5 4 2 1 5.5 min. 14 12 M3.5 Terminal Screw 18 Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 5.5 min. 9 46 7.9 max. 50 7 3 6 5 2 1 11 10 14 12 (Top View) ø3.6 min. 8 4 46 4.4 max. 13 10 DIN Rail (BNDN) 47 6 67 47 8 36 4.4 max. 25 8 Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 14.5 31.5 42 DIN Rail (BNDN) Terminal Blocks 67 26 4.2 18 4.2 M3.5 Terminal Screw 2.5 8 2.5 5.5 min. SH4B-05 31.5 32 40 5 1 (For terminals 13 and 14) (For terminals 1, 5, and 9) 36 8 4 26 4.4 max. 13 25 20 Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 9 4 max. 14.5 DIN Rail (BNDN) 18 Timers 2.5 67 4.4 max. 14 2.5 67 4.2 1 4.8 min. 5.5 min. 16 M3.5 Terminal Screw 5 16 M3 Terminal Screw 31.5 8 47 8 4.2 17 14.5 25 13 9 (Top View) 7.9 max. ø3.6 min. Circuit Breakers USA: 800-262-IDEC Canada: 888-317-IDEC 733 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series Finger-safe DIN Rail Mount Sockets SH1B-05C SH2B-05C 36 22 17 36 M3.5 Terminal Screw 7 DIN Rail (BNDN) Terminal Arrangement ø5 1 Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 48 69 4.2 DIN Rail (BNDN) ø5 5 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 25 8 5 4 1 14 13 12 9 49 25 4.2 M3.5 Terminal Screw 7 69 Switches & Pilot Lights Dimensions con’t (mm) 26 16 M3 Terminal Screw 14 13 18.7 20 (Top View) 29.5 (Top View) 29.5 SH3B-05C 7 M3.5 Terminal Screw 36 25 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 6 5 4 2 1 DIN Rail (BNDN) 49 69 14 12 9 7 3 6 5 2 1 11 10 14 12 Ring terminals cannot be used. 18.7 46 1.7 29.5 40 8 4 46 13 10 (Top View) Ring terminals cannot be used. 18.7 36 Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) ø5 4.2 4.2 8 25 7 Terminal Arrangement 36 1.7 36 42 DIN Rail (BNDN) 49 32 SH4B-05C ø5 13 9 (Top View) 29.5 50 Through Panel Mount Socket SH2B-51 25.6 +0.2 0 11 18.7 3 27 N: No. of sockets mounted 0.3 0.3 (Bottom View) 5.4 min.∗ Timers 3 +0.5 0 1 4 5 8 9 12 13 14 13 14 18 [27 (N–1) + 21.4] Terminal Arrangement (Bottom View) 11 18.7 5.4 min.∗ 1 5 9 25.4 31 Panel Thickness: 1 to 2 +0.2 0 [18 (N–1) + Terminal Arrangement 31 Panel Thickness: 1 to 2 12.4] +0.5 0 25.6 SH1B-51 25.4 Relays & Sockets Ring terminals cannot be used. 18.7 26 30 69 Display Lights 1.7 16 1.7 9 Ring terminals cannot be used. N: No. of sockets mounted ∗ 10.4 min. when using hold-down springs 3.5 3.5 ∗ 10.4 min. when using hold-down springs 2.4 21.2 12.2 SH4B-51 11 18.7 31 25.4 1 2 3 4 5 6 7 8 9 10 11 12 45 N: No. of sockets mounted 3 11 18.7 +0.2 0 +0.2 0 [45 (N–1) + 39.4] +0.5 0 Terminal Arrangement 13 14 (Bottom View) 0.3 0.3 3 25.6 1 2 4 5 6 8 9 10 12 13 36 Panel Thickness: 1 to 2 25.6 [36 (N–1) + Terminal Arrangement 5.4 min.∗ 25.4 31 Terminal Blocks Panel Thickness: 1 to 2 30.4] +0.5 0 14 (Bottom View) 5.4 min.∗ SH3B-51 N: No. of sockets mounted ∗ 10.4 min. when using hold-down springs 3.5 3.5 39.2 Circuit Breakers 30.2 ∗ 10.4 min. when using hold-down springs 734 www.idec.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series Dimensions con’t (mm) Switches & Pilot Lights PCB Mount Sockets SH2B-62 15 (Bottom View) 15 (Tolerance p0.1) 5.65 10 2 8-ø2.4 holes (Tolerance ±0.1) ∗ 34 min. when using hold-down springs Display Lights 6.85 1 2 3 4 5 6 7 8 9 10 11 12 45 3 (Bottom View) 31 min.∗ 6.6 15 11-ø2.4 holes 2 (Tolerance ±0.1) ∗ 36 min. when using hold-down springs 14-ø2.4 holes (Tolerance ±0.1) Relays & Sockets ∗ 36 min. when using hold-down springs 10 10 10 14 11 39.2 45 min. 31.3 12.5 25.4 14 (Bottom View) Terminal Arrangement 13 31 min.∗ 2 31 4.7 10 10 11 15 21.3 0.3 0.3 13 3 36 7.35 12.5 6.65 25.4 31 1 2 4 5 6 8 9 10 12 4.7 6.65 SH4B-62 36 min. Terminal Arrangement 6.6 SH3B-62 30.2 25.4 2-ø2 holes 15.5 14 11 36 min. when using hold-down springs 12.2 3 21.5 min. 2.85 6.6 31 min. 2 1.5 21.2 0.3 (Bottom View) 11 1 4 5 8 9 12 13 5.95 3 Terminal Arrangement 18 min. 4.4 11.85 0.3 13 14 18 6.8 29 1 5 9 4.7 3-ø2.4 holes 4.7 6.95 31 25.4 Terminal Arrangement 29 min.∗ 12.5 SH1B-62 Timers Terminal Blocks Circuit Breakers USA: 800-262-IDEC Canada: 888-317-IDEC 735 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Steven Engineering Technical Question? Ready to Order?