Transcript
MYRICOM, INC. TEST REPORT FOR THE M3-E16 3-SLOT ENCLOSURE WITH M3-SW16-4L, M3-SPINE-8F & M3-M MONITOR LINECARDS EN55024, EN55022 CLASS A, EN61000-3-2, EN61000-3-3, FCC PART 15 SUBPART B CLASS A & CISPR 22 CLASS A COMPLIANCE
DATE OF ISSUE: JANUARY 25, 2001
PREPARED FOR:
PREPARED BY:
Myricom, Inc. 325 N. Santa Anita Avenue Arcadia, CA 91006
Helen Parrish CKC Laboratories, Inc. 5473 A Clouds Rest Mariposa, CA 95338
W.O. No: 75979
Date of test: January 11-12, 2001
Report No: CE01-017
DOCUMENTATION CONTROL:
APPROVED BY:
_____________________________ Tracy Phillips Documentation Control Supervisor CKC Laboratories, Inc.
_____________________________ Dennis Ward Director of Laboratories CKC Laboratories, Inc.
This report contains a total of 72 pages and may be reproduced in full only. Partial reproduction may only be done with the written consent of CKC Laboratories, Inc.
Page 1 of 72 Report No.: CE01-017
TABLE OF CONTENTS Administrative Information .............................................................................................4 Summary Of Results........................................................................................................6 Measurement Uncertainty................................................................................................6 Equipment Under Test (EUT) Description......................................................................6 Peripheral Devices...........................................................................................................7 Specifications and Requirements.....................................................................................8 Report Of Measurements.................................................................................................9 Table 1: Six Highest Radiated Emission Levels - EN55022...............................9 Table 2: Six Highest Conducted Emission Levels - EN55022............................10 Table 3: Six Highest Conducted Emission Levels - EN55022 (Telecom) ..........11 Table 4: Six Highest Conducted Emission Levels - CISPR 22...........................12 Table 5: Six Highest Radiated Emission Levels - FCC > 1GHz.........................13 Table 6: Harmonic Emission Levels ...................................................................14 Table 7: Voltage Fluctuations and Flicker Emission Levels...............................14 Table 8: ESD .......................................................................................................15 Table 9: Radiated Immunity................................................................................16 Table 10: EFTB (AC Power Cable) ....................................................................16 Table 11: EFTB (I/O Cables) ..............................................................................17 Table 12: Surge (AC Power Lines) .....................................................................17 Table 13: Conducted Immunity...........................................................................18 Table 14: Magnetic Immunity .............................................................................18 Table 15: Voltage Dips & Interrupts ...................................................................18 Table A: List Of Test Equipment ....................................................................................19 EUT Setup: Emissions.....................................................................................................20 Radiated Emissions .............................................................................................20 Conducted Emissions ..........................................................................................20 Harmonic Emissions............................................................................................21 Voltage Fluctuation and Flicker Emissions.........................................................21 Radiated Emissions Test (Electric Field) ............................................................22 Conducted Emissions Test ..................................................................................22 Harmonics Test....................................................................................................23 Voltage Fluctuation and Flicker Test ..................................................................23 Sample Calculations ............................................................................................23 Test Methods ...................................................................................................................23 EUT Setup: Immunity .....................................................................................................24 Electrostatic Discharge Test ................................................................................25 Radiated Immunity Test ......................................................................................25 Electrical Fast Transient Burst Test.....................................................................25 Surge Test ............................................................................................................26
Page 2 of 72 Report No.: CE01-017
Conducted Immunity Test ...................................................................................26 Voltage Dips & Interrupts Test ...........................................................................26 Determination of Pass Fail Criterion ...............................................................................27 Monitoring of Operating Parameters...............................................................................27 Appendix A: Information About The Equipment Under Test........................................28 I/O Ports...............................................................................................................29 Crystal Oscillators ...............................................................................................29 Printed Circuit Boards .........................................................................................29 Cable Information................................................................................................30 Equipment Test Setup Diagram...........................................................................31 Photograph Showing Radiated Emissions...........................................................32 Photograph Showing Radiated Emissions...........................................................33 Photograph Showing Conducted Emissions........................................................34 Photograph Showing Conducted Emissions........................................................35 Photograph Showing Conducted Emissions........................................................36 Photograph Showing Conducted Emissions........................................................37 Photograph Showing Flicker & Harmonic Emissions.........................................38 Photograph Showing Electrostatic Discharge .....................................................39 Photograph Showing Electrostatic Discharge Points ..........................................40 Photograph Showing Electrostatic Discharge Points ..........................................41 Photograph Showing Radiated Immunity............................................................42 Photograph Showing Electrical Fast Transient Burst..........................................43 Photograph Showing Surge Immunity ................................................................44 Photograph Showing Conducted Immunity ........................................................45 Photograph Showing Voltage Dips And Interrupts.............................................46 Appendix B: Measurement Data Sheets.........................................................................47
Page 3 of 72 Report No.: CE01-017
CKC Laboratories, Inc. has Certificates of Accreditation from the following agencies: DATech (Germany); A2LA (USA); FCC (USA); VCCI (Japan); BSMI (Taiwan); HOKLAS (Hong Kong). CKC Laboratories, Inc. has Letters of Acceptance through an MRA for the following agencies: ACA/NATA (Australia); SABS (South Africa); SWEDAC (Sweden); TUV Rheinland-Germany; TUV RheinlandKorea; TUV Rheinland-Russia; Radio Communications Agency (RA); NEMKO (Norway).
ADMINISTRATIVE INFORMATION
DATE OF TEST:
January 11-12, 2001
DATE OF RECEIPT:
January 11, 2001
PURPOSE OF TEST:
To demonstrate the compliance of the M3E16 3-Slot Enclosure with M3-SW16-4L, M3-SPINE-8F & M3-M Monitor Linecards with the requirements for EN55024, EN55022 Class A, EN61000-3-2, EN610003-3, FCC Part 15 Subpart B Class A & CISPR 22 Class A devices.
MANUFACTURER:
Myricom, Inc. 325 N. Santa Anita Avenue Arcadia, CA 91006
REPRESENTATIVE:
Alan Kulawik
TEST LOCATION:
CKC Laboratories, Inc. 110 Olinda Place Brea, CA 92621
TEST PERSONNEL:
Stuart Yamamoto Test Engineer
TEST METHOD:
EN55024 1998, EN55022 1998, EN610003-2 1995, EN61000-3-3 1995, ANSI C63.4 1992, CISPR 22 1985
Page 4 of 72 Report No.: CE01-017
EQUIPMENT UNDER TEST: M3-E16 3-Slot Enclosure Manuf: Myricom, Inc. Model: M3-E16 Serial: 64652
10BaseT Ethernet Monitor Linecard Manuf: Myricom, Inc. Model: M3-M Monitor Linecard Serial: 68340
8 Port Fiber Myrinet Card Manuf: Myricom, Inc. Model: M-3 SPINE-8F Serial: 64289
4 Port Myrinet LAN Card Manuf: Myricom, Inc. Model: M3-SW16-4L Serial: 64652
Page 5 of 72 Report No.: CE01-017
SUMMARY OF RESULTS For the European Union, the Myricom, Inc. M3-E16 3-Slot Enclosure with M3-SW16-4L, M3SPINE-8F & M3-M Monitor Linecards was tested in accordance with EN55024 1998, EN610003-2 1995, EN61000-3-3 1995 & EN55022 1998 for compliance. As received, the equipment under test was found to be fully compliant with the limits of EN55024, EN61000-3-2, EN610003-3 & EN55022 Class A. The results in this report apply only to the items tested, as identified herein. For Australia/New Zealand, the equipment under test was found to be fully compliant with AS/NZS 3548 Class A, using the EN55022 specifications and methods. For Japan, the equipment under test was found to be fully compliant with the VCCI Class A requirements, using the CISPR 22 specifications and methods. For the US and Canada, the equipment under test was found to be fully compliant with the FCC Part 15 Subpart B & ICES-003 Class A limits, using the FCC Part 15 Subpart B and CISPR 22 1985 specifications and ANSI C63.4 1992 methods.
MEASUREMENT UNCERTAINTY Associated with data in this report is a ± 4dB measurement uncertainty. EQUIPMENT UNDER TEST (EUT) DESCRIPTION Myricom Switch (4 Myrinet LAN ports & 8 Myrinet 2000 Fiber ports & M3-M monitor linecard with 2 ethernet ports).
Page 6 of 72 Report No.: CE01-017
PERIPHERAL DEVICES The EUT was tested with the following peripheral(s): Hub Manuf: Model: Serial:
Netgear FS108 F518E06050651
Monitor Manuf: Miracle Model: MO935 Serial: 90052394
Keyboard Manuf: HP Model: 5129 Serial: F02605917
Mouse Manuf: Model: Serial:
Computer Manuf: HP Model: Pavilion 6735 Serial: KR03109769
Myrinet 2000 Fiber Optic PCI Card Manuf: Myricom, Inc. Model: M3F-PCI64B-8 Serial: 63007
HP MS-34 LZN01904868
Page 7 of 72 Report No.: CE01-017
SPECIFICATIONS AND REQUIREMENTS The following summarizes the specifications and requirements for EN55024, EN55022 Class A, EN61000-3-2, EN61000-3-3, FCC Part 15 Subpart B Class A & CISPR 22 Class A emission and immunity tests performed on the M3-E16 3-Slot Enclosure with M3-SW16-4L, M3-SPINE-8F & M3-M Monitor Linecards. If the actual test levels are higher or different than required, these levels are listed in the appropriate tables. Test
Specification
Requirement
Radiated Emissions
EN55022, FCC Part 15 Subpart B
Class A
Conducted Emissions
EN55022, CISPR 22
Class A
Electrostatic Discharge
EN61000-4-2 EN55024
+4 kV contact +8kV air
Harmonic Emissions
EN61000-3-2
See standard
Voltage Fluctuations and Flicker Emissions
EN61000-3-3
See standard
Radiated Immunity
EN61000-4-3 EN55024
3 V/m
Electrical Fast Transient Burst
EN61000-4-4 EN55024
1kV (AC), .5kV (I/O)
Surge
EN61000-4-5 EN55024
2kV common mode 1kV differential mode
Conducted Immunity
EN61000-4-6 EN55024
3V rms
Magnetic Immunity
EN61000-4-8 EN55024
1 A/m (not applicable)
Voltage Dips & Interrupts
EN61000-4-11 EN55024
>95%, 30% & >95%
Page 8 of 72 Report No.: CE01-017
REPORT OF MEASUREMENTS
The following tables report the six highest worst case levels recorded during the tests performed on the M3-E16 3-Slot Enclosure with M3-SW16-4L, M3-SPINE-8F & M3-M Monitor Linecards. All readings taken are peak readings unless otherwise noted by a “Q” or “A”. The data sheets from which the radiated and conducted tables were compiled are contained in Appendix B.
Table 1: Six Highest Radiated Emission Levels - EN55022
FREQUENCY MHz
METER READING dBµV
CORRECTED READING dBµV/m
SPEC LIMIT dBµV/m
MARGIN dB
NOTES
159.979
40.6
17.8
-28.6
2.4
32.2
40.0
-7.8
V
499.990
48.5
16.9
-28.0
4.4
41.8
47.0
-5.2
H
749.996
40.4
21.5
-28.1
5.2
39.0
47.0
-8.0
H
875.012
40.4
23.0
-27.4
5.7
41.7
47.0
-5.3
V
879.565
38.8
23.1
-27.4
5.7
40.2
47.0
-6.8
H
999.998
36.9
24.3
-28.2
6.3
39.3
47.0
-7.7
V
Test Method: Spec Limit : Test Distance:
CORRECTION FACTORS Ant Amp Cable Dist dB dB dB dB
BS EN55022 1998 EN55022 Class A 10 Meters
NOTES:
H = Horizontal Polarization V = Vertical Polarization Q = Quasi Peak Reading A = Average Reading
COMMENTS: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. PowerOne power supply, MPU150-S259. Voltage to EUT is 235 VAC, 50 Hz, Temperature: 18.5°C, Humidity: 56%.
Page 9 of 72 Report No.: CE01-017
Table 2: Six Highest Conducted Emission Levels - EN55022
FREQUENCY MHz
METER READING dBµV
0.154144
49.0
0.191856
CORRECTED READING dBµV
SPEC LIMIT dBµV
MARGIN dB
NOTES
0.0
49.0
66.0
-17.0
B
55.2
0.0
55.2
66.0
-10.8
B
0.215478
47.8
0.0
47.8
66.0
-18.2
B
0.249874
44.1
0.0
44.1
66.0
-21.9
W
0.641928
43.2
0.0
43.2
60.0
-16.8
W
0.825838
33.8
0.0
33.8
60.0
-26.2
W
Test Method: Spec Limit :
CORRECTION FACTORS Lisn dB dB dB dB
BS EN55022 1998 EN55022 Class A
NOTES:
Q = Quasi Peak Reading A = Average Reading B = Black Lead W = White Lead
COMMENTS: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. PowerOne power supply, MPU150-S259. Voltage to EUT is 235 VAC, 50 Hz, Temperature: 18.5°C, Humidity: 56%.
Page 10 of 72 Report No.: CE01-017
Table 3: Six Highest Conducted Emission Levels - EN55022 (Telecom)
FREQUENCY MHz
METER READING dBµV
0.641928
38.2
5.784664
CORRECTED READING dBµV
SPEC LIMIT dBµV
MARGIN dB
NOTES
9.5
47.7
74.0
-26.3
N
34.7
9.5
44.2
74.0
-29.8
N
6.189132
33.1
9.5
42.6
74.0
-31.4
N
8.102312
34.8
9.5
44.3
74.0
-29.7
N
10.307520
33.4
9.5
42.9
74.0
-31.1
N
12.512720
33.7
9.5
43.2
74.0
-30.8
N
Test Method: Spec Limit :
CORRECTION FACTORS Lisn dB dB dB dB
BS EN55022 1998 EN55022 Class A
NOTES:
N = None
COMMENTS: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. PowerOne power supply, MPU150-S259. Voltage to EUT is 235 VAC, 50 Hz, Temperature: 18.5°C, Humidity: 56%.
Page 11 of 72 Report No.: CE01-017
Table 4: Six Highest Conducted Emission Levels - CISPR 22
FREQUENCY MHz
METER READING dBµV
0.191856
56.6
0.254018
CORRECTED READING dBµV
SPEC LIMIT dBµV
MARGIN dB
NOTES
0.0
56.6
66.0
-9.4
B
44.2
0.0
44.2
66.0
-21.8
W
0.638811
43.9
0.0
43.9
60.0
-16.1
W
0.832072
34.1
0.0
34.1
60.0
-25.9
B
9.910581
33.2
0.0
33.2
60.0
-26.8
W
22.083310
33.2
0.0
33.2
60.0
-26.8
W
Test Method: Spec Limit :
CORRECTION FACTORS Lisn dB dB dB dB
ANSI C63.4 1992 CISPR 22 Class A
NOTES:
Q = Quasi Peak Reading A = Average Reading B = Black Lead W = White Lead
COMMENTS: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. PowerOne power supply, MPU150-S259. Voltage to EUT is 110 VAC, 60 Hz, Temperature: 18.5°C, Humidity: 56%.
Page 12 of 72 Report No.: CE01-017
Table 5: Six Highest Radiated Emission Levels - FCC > 1GHz
FREQUENCY MHz
METER READING dBµV
CORRECTED READING dBµV/m
SPEC LIMIT dBµV/m
MARGIN dB
NOTES
1749.960
54.3
24.9
-40.5
4.7
43.4
49.5
-6.1
H
2000.027
53.0
26.2
-40.5
4.9
43.6
49.5
-5.9
V
2124.990
51.5
26.9
-39.8
5.1
43.7
49.5
-5.8
V
2249.989
50.0
27.5
-39.1
5.2
43.6
49.5
-5.9
V
2499.973
47.9
28.7
-37.8
5.7
44.5
49.5
-5.0
H
5000.015
45.7
32.9
-41.1
6.8
44.3
49.5
-5.2
H
Test Method: Spec Limit : Test Distance:
CORRECTION FACTORS Ant Amp Cable Dist dB dB dB dB
ANSI C63.4 1992 FCC Class A 10 Meters
NOTES:
H = Horizontal Polarization V = Vertical Polarization Q = Quasi Peak Reading A = Average Reading
COMMENTS: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. Frequency range scanned and maximized, 1-6.25 GHz. Power-One power supply, MPU150S259. Voltage to EUT is 110 VAC, 60 Hz, Temperature: 18.5°C, Humidity: 56%.
Page 13 of 72 Report No.: CE01-017
Table 6: EN61000-3-2 Tested By: Stuart Yamamoto Harmonic Emissions √
Pass / Fail Pass
Notes: See Appendix B for test data sheets.
Table 7: EN61000-3-3 Tested By: Stuart Yamamoto Voltage Fluctuations and Flicker Emissions √
Pass / Fail Pass
Notes: See Appendix B for test data sheets.
Page 14 of 72 Report No.: CE01-017
EN55024 1998 Table 8: EN61000-4-2 ESD Tested By: S. YAMAMOTO Location Discharge Contact + 4 kV Air + 8 kV pass / fail pass / fail Point 1* Pass N/A Point 2* Pass N/A Point 3* Pass N/A Point 4* Pass N/A Point 5* Pass N/A Point 6* Pass N/A *Point 1: Front side of EUT including connectors. *Point 2: Back side of EUT including connector. *Point 3: Left side of EUT. *Point 4: Right side of EUT. *Point 5: Top side of EUT. *Point 6: All four sides of HCP. Relative Humidity:
54%
Performance Criterion B B B B B B
Temperature:
18°C
Atmospheric Pressure:
101kPa
Notes:
This data sheet is for the M3-16 with M3-M, Spine-8F, and M3-SW16-4L. No degradations occurred on points 2, 3, 4 and 5. Point 1: occasionally errors occurred upon ESD however EUT recovered without operator intervention. N/A-not applicable. The test is not applicable due to all sides of the EUT being metal and direct contact discharges were applied.
Failure Criteria:
No degradation of performance or loss of function below a performance level specified by the manufacturer.
Page 15 of 72 Report No.: CE01-017
EN55024 1998 Table 9: EN61000-4-3 Radiated Immunity Tested By: S. YAMAMOTO Frequency Range Front Back V/H V/H
Left Side V/H
80-1000 MHz at 3 V/m Pass Pass Pass w/80% AM at 1 kHz Temperature: 18°C Relative Humidity: 44%
Right Side V/H
Performance Criterion Met
Pass
A
Atmospheric Pressure:
101kPa
Notes: Failure Criteria:
No degradation of performance or loss of function below a performance level specified by the manufacturer.
Table 10: EN61000-4-4 Electrical Fast Transient Burst (AC Power Cable) Tested By: S. YAMAMOTO - 1 kV EFTB insertion point + 1 kV pass fail pass fail Line to Ground Pass Pass
Performance Criterion Met B
Neutral to Ground
Pass
Pass
B
Protective Earth to Ground
Pass
Pass
B
Line/Neutral/Protective Earth to Ground. Pass Temperature: 18°C Relative Humidity: 54%
Pass B Atmospheric Pressure: 101kPa
Notes: Failure Criteria:
No degradation of performance or loss of function below a performance level specified by the manufacturer.
Page 16 of 72 Report No.: CE01-017
EN55024 1998 Table 11: EN61000-4-4 Electrical Fast Transient Burst (I/O cables ) Tested By: S. YAMAMOTO Cable tested + .5 kV - .5 kV Performance pass / fail pass / fail Criterion Met RJ45 Ethernet Cable Pass Pass B LAN Pass Pass B Temperature: 18°C Relative Humidity: 54% Atmospheric Pressure: 101kPa Notes: Failure Criteria:
No degradation of performance or loss of function below a performance level specified by the manufacturer.
Table 12: EN61000-4-5 Surge (AC Power Lines) Tested By: S. YAMAMOTO Voltage Insertion 0 degrees 90 degrees 180 degrees 270 degrees Performance level points input input input input Criterion kV +voltage- +voltage+voltage+voltagepass / fail pass / fail pass / fail pass / fail line 1 pass pass pass pass B neutral line 2 pass pass pass pass B ground neutral 2 pass pass pass pass B ground Temperature: 18°C Relative Humidity: 54% Atmospheric Pressure: 101kPa Notes: Failure Criteria:
No degradation of performance or loss of function below a performance level specified by the manufacturer.
Page 17 of 72 Report No.: CE01-017
EN55024 1998 Table 13: EN61000-4-6 Conducted Immunity Tested By: S. YAMAMOTO Cable Tested Amplitude Frequency Range AC Power Line 3 Vrms .15-80MHz RJ45 Ethernet 3 Vrms .15-80MHz DB LAN 3 Vrms .15-80MHz Temperature: 18°C Relative Humidity:
Pass/fail
Performance Level
Pass A Pass A Pass A 54% Atmospheric Pressure:
101kPa
Notes:
Modulated with a 1kHz sine wave at 80%.
Failure Criteria:
No degradation of performance or loss of function below a performance level specified by the manufacturer.
Table 14: EN61000-4-8 Magnetic Immunity Tested By: N/A Device under test Amplitude X-Axis Y-Axis Enclosure 1 A/m N/A N/A Temperature: N/A Relative Humidity:
Z-Axis Performance Level N/A N/A N/A Atmospheric Pressure: N/A
Notes:
N/A: Not applicable. This test is not applicable to this type of equipment.
Failure Criteria:
N/A
Table 15: EN61000-4-11 Voltage Dips & Interrupts Tested By: S. YAMAMOTO Device Under Test Interrupts Time
Pass/fail
Performance Notes Level AC Input Power 100% 0.5 period (10ms) Pass B 5 interrupts AC Input Power 30% 25 periods (500ms) Pass C 5 interrupts AC Input Power 100% 250 periods (5sec) Pass C 1 drop out Temperature: 18°C Relative Humidity: 54% Atmospheric Pressure: 101kPa Notes: Failure Criteria:
100% for 10ms:
Failure Criteria:
30% for 500ms & 100% for 5000ms:
No degradation of performance or loss of function below a performance level specified by the manufacturer. Temporary loss can occur, provided that the function can be restored by the operation of the controls.
Page 18 of 72 Report No.: CE01-017
TABLE A LIST OF TEST EQUIPMENT Brea VCCI Acceptance No. R-301 & C-314 Industry Canada File No. IC 3172 Emissions Equipment Bicon Antenna Log Periodic Antenna Pre-amp Antenna cable Pre-amp to SA cable Horn Antenna Microwave Pre-amp ¼” Heliax Coaxial Cable ¼” Heliax Coaxial Cable Spectrum Analyzer QP Adapter LISN Spectrum Analyzer TLISN Power Analyzer Immunity Equipment ESD Simulator Amplifier Antenna Directional Coupler Spectrum Analyzer Signal Generator EFT Generator Capacitive Coupling Clamp Surge Generator Amplifier Coupling Decoupling Network Injection Probe Programmable Power Source
Manufacturer A.H. System A.H. System HP NA NA Emco HP Andrew Andrew HP. HP Emco HP FCC Voltech
Model SAS-200/540 SAS-200/516 8447D RG214 RG58 3115 83017A FSJ-50A-4 FSJ-50A-4 8566B 85650A 3816/2NM 8566B FCC-TLISN-T4 PM3000A
Serial Number 220 331 1937A02548 Cable#15 Cable#10 9603-4683 3123A00282 Cable#7 (6 ft) Cable#14 (60ft) 2532A02509 3303A01884 9809-1090 2532A02509 15550 1730
Cal Date 092000 092000 030700 122000 091800 020700 030100 071800 071800 092600 092600 030800 092600 080800 092500
Cal Due 092001 092001 030701 122001 091801 020701 030101 071801 071801 092601 092601 030801 092601 080801 092501
Manufacturer Keytek AR Emco Werlatone HP Marconi Velonex Velonex
Model # MZ-15ec 50W1000A 3143 C2630 8568A 2022D V3300 V3334
Serial Number 9503235 14335 9608-1265 3806 2049A1287 119158/054 16692 16701
Cal Date 080200 030700 090900 030700 101200 050800 030900 020100
Cal Due 080201 030701 090901 030701 101201 050801 030901 020101
Keytek AR Fisher
EMCPro 100W100 FCC-801-M3-25
9901255 14328 57
020800 030700 050900
020801 030701 050901
Fisher Pacific PS
F-120-1 345AMX / UPC32
62 250 / 245
030700 070700
030701 070701
Page 19 of 72 Report No.: CE01-017
EUT SETUP: Emissions The equipment under test (EUT) and the peripheral(s) listed were set up in a manner that represented their normal use, as shown in the photographs in Appendix A. Any special conditions required for the EUT to operate normally are identified in the comments that accompany Tables 1 and 5 for radiated emissions and Tables 2, 3 and 4 for conducted emissions. Additionally, a complete description of all ports and I/O cables is included on the information sheets contained in Appendix A. Radiated Emissions During radiated emissions testing, the EUT was mounted on a nonconductive, rotating table 80 cm above the conductive grid. The nonconductive table dimensions were 1 meter by 1.5 meters. This configuration is typical for radiated emissions testing of table top devices. Conducted Emissions During conducted emissions testing, the EUT was located on a wooden table measuring approximately 80 cm high, 1 meter deep, and 1.5 meters in length. One wall of the room where the EUT is located has a minimum 2 meter by 2 meter conductive plane. The EUT was mounted on the wooden table 40 cm away from the conductive plane, and 80 cm from any other conductive surface. The vertical metal plane used for conducted emissions was grounded to the earth. Power to the EUT was provided through a LISN. The LISN was grounded to the ground plane. All other objects were kept a minimum of 80 cm away from the EUT during the conducted test. Conducted emissions tests required the use of the LISNs listed in Table A. The power cord and I/O cables were routed consistent with the typical application by varying the configuration of the test sample. Interface cables were connected to the available I/O ports of the test unit. The effect of varying the position of the cables was investigated to find the configuration that produced maximum emissions. This configuration was precisely noted in the test report. I/O cables were of the type and length specified in the individual requirements. The length of cable that produced maximum emissions was selected. For detail on the disposition of the cables during the test, refer to the "Cable Information Sheet" and the photographs contained in Appendix A.
Page 20 of 72 Report No.: CE01-017
Harmonic Emissions During harmonics testing, the EUT was placed on a nonconductive, table 80 cm above the conductive grid. The nonconductive table dimensions were 1 meter by 1.5 meters. This configuration is typical for harmonic emissions testing of table top devices. Voltage Fluctuation and Flicker Emissions During voltage fluctuation and flicker testing, the EUT was placed on a nonconductive, table .80 cm above the conductive grid. The nonconductive table dimensions were 1 meter by 1.5 meters. This configuration is typical for voltage fluctuation and flicker emissions testing of table top devices.
Page 21 of 72 Report No.: CE01-017
Radiated Emissions Test (Electric Field) During the preliminary radiated scan, the EUT was powered up and operating in its defined test mode with the I/O and power cords facing the antenna. The frequency range of 30 MHz - 88 MHz was then scanned with the biconical antenna located about 1.5 meter above the ground plane in the vertical configuration. During this scan, the turntable was rotated and all peaks which were at or near the limit were recorded. The frequency range of 100 - 300 MHz was scanned in the same manner, with the biconical antenna, and the peaks recorded. Lastly, a scan of the FM band from 88 - 110 MHz was made, using a reduced resolution bandwidth and a reduced frequency span. The biconical antenna was changed to the horizontal polarity and the above steps were repeated. After changing to the log periodic antenna in the horizontal configuration, the frequency range of 300 - 1000 MHz was scanned. The log periodic antenna was changed to the vertical polarity and the frequency range of 300 - 1000 MHz was again scanned. For frequencies exceeding 1000 MHz, the horn antenna was used. Care was taken to ensure that no frequencies were missed within the FM and TV bands. An analysis was performed to determine if the signals that were at or near the limit were caused by an ambient transmission. If unable to determine by analysis, the equipment was powered down to make the final determination if the EUT was the source of the emission. A thorough scan of all frequencies was made manually using a small frequency span, rotating the turntable as needed. The test engineer maximized the readings with respect to the table rotation, antenna height, and configuration of the peripheral(s) and cables. Maximizing of the cables and peripheral locations was achieved by monitoring the spectrum analyzer on a closed circuit television monitor while the EUT components and cables were being moved and rearranged on the EUT table for maximum emissions. Photographs showing the final worst case configuration of the EUT are contained in Appendix A. Conducted Emissions Test For the conducted emissions, the LISNs used were 50 µH-/+50 ohms. Above 150 kHz, a 0.15 µF series capacitor is added in-line prior to connecting the analyzer to restore the proper impedance for the range. A 30 to 50 second sweep time was used for automated measurements in the frequency bands of 150 kHz - 500 kHz, and 500 kHz to 30 MHz. All readings within 20 dB of the limit were recorded, and those within 6 dB of the limit were examined with additional measurements using a slower sweep time.
Page 22 of 72 Report No.: CE01-017
Harmonic Emissions Test Harmonics emissions data was taken with the Voltech Measuring Device. The harmonics of the M3-E16 3-Slot Enclosure with M3-SW16-4L, M3-SPINE-8F & M3-M Monitor Linecards power supply conductors were tested in accordance with EN61000-3-2 and measurements were found not to exceed the values calculated from EN61000-3-2 emission limits. Voltage Fluctuation and Flicker Test Voltage fluctuation and flicker emissions data was taken with the Voltech Measuring Device. The voltage fluctuation and flicker of the M3-E16 3-Slot Enclosure with M3-SW16-4L, M3SPINE-8F & M3-M Monitor Linecards power supply conductors were tested in accordance with EN61000-3-3. The data was then compared to the EN61000-3-3 emission limits to determine compliance.
Sample Calculations The basic spectrum analyzer reading was converted using correction factors as shown in the six highest emissions readings in Tables 1 through 5. For radiated emissions in dBµV/m, the spectrum analyzer reading in dBµV was corrected by using the following formula: Meter reading (dBµV) + Antenna Factor (dB) + Cable Loss (dB) - Distance Correction (dB) - Pre-amplifier Gain (dB) = Corrected Reading (dBµV/m) This reading was then compared to the applicable specification limit to determine compliance. Test Methods The radiated and conducted emissions data of the M3-E16 3-Slot Enclosure with M3-SW16-4L, M3-SPINE-8F & M3-M Monitor Linecards was taken with the HP Spectrum Analyzer. Incorporating the applicable correction factors for distance, antenna, cable loss and amplifier gain, the data was reduced as shown in the "Sample Calculations". The corrected data was then compared to the EN55022 Class A, FCC Part 15 Subpart B Class A and CISPR 22 Class A emission limits to determine compliance. Preliminary and final measurements were taken in order to ensure that all emissions from the EUT were found and maximized. Page 23 of 72 Report No.: CE01-017
EUT SETUP: Immunity The equipment under test (EUT) and the peripheral(s) listed in the EUT description and peripheral devices tables were set up in a manner that represented their normal use, as shown in the setup photographs in Appendix A. Any special conditions required for the EUT to operate normally are identified in the comments that accompany the appropriate table for Electrostatic Discharge, Radiated Immunity, Electrical Fast Transient Burst (EFTB) on the Power Cord, Electrical Fast Transient Burst on the I/O Cables, Surge on the Power Cord, Conducted Immunity, and for the Voltage Dips & Interrupts. Additionally, a complete description of all ports and I/O cables is included on the information sheets contained in Appendix A. During radiated immunity, voltage dips & interrupts, surge, and EFTB testing, the EUT was mounted on a nonconductive table 80 cm above the conductive grid. The nonconductive table dimensions were 1 meter by 1.5 meters. This configuration is typical for radiated immunity testing of table top devices. During conducted immunity testing, the EUT was placed on a nonconductive table, located 10 cm above the ground reference plane. During Electrostatic Discharge testing, the EUT was located on a wooden table measuring approximately 80 cm high, 1 meter deep, and 1.5 meters in length. A horizontal coupling plane, 1.6 meters by 0.8 meters, was placed on top of the table. The EUT was then placed on an .5mm thick insulating material. A 0.1 meter separation from the coupling plane was obtained. The horizontal coupling plane was electrically bonded through two 470 kΩ series resistors to the earth reference plane on the floor, which is attached to the ground on the electrical outlet service. The vertical coupling plane, when used, is electrically bonded in the same manner as the horizontal coupling plane. The ESD generator (ESD gun) was grounded to the metal ground reference plane on the floor. The ESD generator power supply was located on the ground reference plane. The power cord and I/O cables were routed consistent with the typical application by varying the configuration of the test sample. Interface cables were connected to the available I/O ports of the test unit. The effect of varying the position of the cables was investigated to find the configuration that produced maximum susceptibility. This configuration was precisely noted in the test report. I/O cables were of the type and length specified in the individual requirements. The length of cable which produced maximum susceptibility was selected. For detail on the disposition of the cables during the test, refer to the "Cable Information Sheet" and the photographs contained in Appendix A.
Page 24 of 72 Report No.: CE01-017
Electrostatic Discharge Test During this test the ESD generator was positioned at least 0.1 meter from the EUT and in contact with the metal coupling plane. At least 200 single shot discharges, 100 each at negative and positive, were applied to the horizontal coupling plane in at least four test points, one of the test points being the center front edge of the horizontal coupling plane. Each test point received a minimum of 50 direct contact discharges. These test were performed at a maximum repetition rate of one discharge per second. A minimum of 10 single discharges were applied to the selected test points. The M3-E16 3-Slot Enclosure with M3-SW16-4L, M3-SPINE-8F & M3-M Monitor Linecards was tested in accordance with EN55024 and EN61000-4-2 and meets Performance Criterion B.
Radiated Immunity Test A field strength of 3V/m was established from 80MHz to 1000MHz. This frequency range was modulated with a 1kHz sine wave at 80%. The signal generators provided the modulated frequency at a 1% step size to the RF amplifiers. The RF amplifiers provided the necessary power to the antenna to establish the field levels. The antenna was positioned 1 meter from all four faces of the EUT. A biconilog antenna was used to cover the range of 80 to 1000 MHz in both polarizations. The M3-E16 3-Slot Enclosure with M3-SW16-4L, M3-SPINE-8F & M3-M Monitor Linecards was tested in accordance with EN55024 and EN61000-4-3 and meets Performance Criterion A at a field strength of 3V/m.
Electrical Fast Transient Burst Test Test voltages of up to 1kV in (+) and (-) polarities were applied to the AC power cords and up to 0.5kV was applied to the I/O cables. The test voltages were at a 5kHz pulse repetition frequency and were applied for 60 seconds between ground and each power supply terminal and between ground and protective earth. The coupling clamp was used to apply 0.5kV to the I/O cables. The M3-E16 3-Slot Enclosure with M3-SW16-4L, M3-SPINE-8F & M3-M Monitor Linecards was tested in accordance with EN55024 and EN61000-4-4 and meets Performance Criterion B.
Page 25 of 72 Report No.: CE01-017
Surge Test Test voltages of up to 2kV common mode and 1kV differential mode in (+) and (-) polarities were applied to the EUT power cords. Characteristics of the test voltage were 1.2µs rise time and 50µs pulse width. These surges were synchronized to the 0, 90, 180 and 270 degree phase angles of the power frequency. The M3-E16 3-Slot Enclosure with M3-SW16-4L, M3-SPINE8F & M3-M Monitor Linecards was tested in accordance with EN55024 and EN61000-4-5 and meets Performance Criterion B.
Conducted Immunity Test A 3 Vrms level was established from 150kHz to 80MHz. This frequency range was modulated with 1 kHz sine wave at 80%. The signal generators provided the modulated frequency at a 1% step size to the RF amplifiers. The RF amplifiers provided the necessary power to the CDN and injection probe to establish the 3 volt level. The injection probe was positioned 0.3 meters from the rear of the EUT. The M3-E16 3-Slot Enclosure with M3-SW16-4L, M3-SPINE-8F & M3-M Monitor Linecards was tested in accordance with EN55024 and EN61000-4-6 and meets Performance Criterion A at 3 Vrms.
Voltage Dips and Interrupts Test Power to the EUT was supplied by a programmable power supply. This power supply produced the following voltage dips and interrupts for EN55024: a 100% reduction in voltage for 0.5 period (10ms), a 30% reduction in voltage for 25 periods (500ms), and a 100% reduction in voltage for 250 periods (5 seconds). The M3-E16 3-Slot Enclosure with M3-SW16-4L, M3SPINE-8F & M3-M Monitor Linecards was tested in accordance EN55024 and EN61000-4-11 and meets performance Criteria B for a 100% reduction for 0.5 period, Criteria C for a 30% reduction for 25 periods and Criteria C for a 100% reduction in voltage for 250 periods.
Page 26 of 72 Report No.: CE01-017
DETERMINATION OF PASS FAIL CRITERION During all immunity tests, the item (M3-E16 3-Slot Enclosure with M3-SW16-4L, M3-SPINE8F & M3-M Monitor Linecards) did not deviate or change greater than the permissible variation as indicated in the test report and by consultation with Myricom, Inc.
MONITORING OF OPERATING PARAMETERS The device was monitored during the tests by means of a visual check whereby the essential parameters were displayed.
Page 27 of 72 Report No.: CE01-017
APPENDIX A INFORMATION ABOUT THE EQUIPMENT UNDER TEST
Page 28 of 72 Report No.: CE01-017
INFORMATION ABOUT THE EQUIPMENT UNDER TEST Test Software/Firmware: Fast_test9r.dat CRT was displaying: Status Power Supply Manufacturer: Power-One Power Supply Part Number: MPU150-S259 AC Line Filter Manufacturer: Corcom AC Line Filter Part Number: 3ED8 The AC power cord is removable and is NOT shielded Line voltage used during testing: 110VAC 60Hz/235VAC 50Hz
I/O PORTS Type Myrinet LAN Myrinet 2000 FIBER Ethernet 10Base-T
Function Monitor with ethernet 8 Myrinet Fiber ports 4 Myrinet LAN ports
# 4 8 2
CRYSTAL OSCILLATORS Type Freq In MHz 16, 20, 125
PRINTED CIRCUIT BOARDS Model & Rev Clocks, MHz M3-M monitor 4, 8, 16, 20, 48 linecard M3-SPINE-8F 4, 8, 16, 40, 62.5, 125, 1250 M3-SW16-4L 4, 8, 16, 40, 80, 62.5
Layers 8
Location All Layers
8 8
All Layers All Layers
Page 29 of 72 Report No.: CE01-017
CABLE INFORMATION Cable #: Cable Type: Construction: Connected To End (1): Connector At End (1): Shield Grounded At (1): Part Number: Notes: Cable #: Cable Type: Construction: Connected To End (1): Connector At End (1): Shield Grounded At (1): Part Number: Notes: Cable #:
1
Cable(s) of this type:
Myrinet LAN Shield Type: Twisted Pair Length In Meters: EUT Connected To End (2): DB-37 Connector At End (2): YES Shield Grounded At (2): M2F-CB-35 Number of Conductors: Used for loopback on EUT 2
Cable(s) of this type:
Fiber Optic
Shield Type: Length In Meters: EUT Connected To End (2): LC Connector At End (2): Shield Grounded At (2): M3F-CB-1M Number of Conductors: Used for loopback on EUT 3
Braid and foil 10 EUT DB-37 YES 37
N/A 1 EUT LC
Cable(s) of this type:
Cable Type: Fiber Construction: Fiber Optic Connected To End (1): EUT Connector At End (1): Shield Grounded At (1): Part Number: Notes: Cable #:
Shield Type: Length In Meters: 8 Connected To End (2): M3F-PCI64B-8 PCI card in a PC LC Connector At End (2): LC M3F-CB-8M Shield Grounded At (2): Number of Conductors: Used to connect EUT to a remote PC 4
Cable(s) of this type:
Cable Type: Twisted Pair CAT5 Construction: Unshielded Connected To End (1): EUT Connector At End (1): Shield Grounded At (1): Part Number: Notes:
Shield Type: None Length In Meters: 10 Connected To End (2): M3F-PCI64B-8 PCI card in a PC RJ45 Connector At End (2): RJ45 Shield Grounded At (2): Number of Conductors: 8 Used to connect EUT's M3-M linecard to a 10Mbit ethernet hub Page 30 of 72 Report No.: CE01-017
EQUIPMENT TEST SETUP DIAGRAM
Page 31 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING RADIATED EMISSIONS
Radiated Emissions - Front View
Page 32 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING RADIATED EMISSIONS
Radiated Emissions - Back View
Page 33 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING CONDUCTED EMISSIONS
Conducted Emissions - Front View
Page 34 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING CONDUCTED EMISSIONS
Conducted Emissions - Back View
Page 35 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING CONDUCTED EMISSIONS
Conducted Emissions - Front View (Telecom)
Page 36 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING CONDUCTED EMISSIONS
Conducted Emissions - Back View (Telecom)
Page 37 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING FLICKER & HARMONIC EMISSIONS
Flicker & Harmonic Emissions
Page 38 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING ELECTROSTATIC DISCHARGE
Electrostatic Discharge
Page 39 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING ELECTROSTATIC DISCHARGE POINTS
Electrostatic Discharge Points
Page 40 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING ELECTROSTATIC DISCHARGE POINTS
Electrostatic Discharge Points
Page 41 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING RADIATED IMMUNITY
Radiated Immunity - Front View
Page 42 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING ELECTRICAL FAST TRANSIENT BURST
Electrical Fast Transient Burst - Power Lines
Page 43 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING SURGE IMMUNITY
Surge Immunity
Page 44 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING CONDUCTED IMMUNITY
Conducted Immunity
Page 45 of 72 Report No.: CE01-017
PHOTOGRAPH SHOWING VOLTAGE DIPS AND INTERRUPTS
Voltage Dips and Interrupts
Page 46 of 72 Report No.: CE01-017
APPENDIX B MEASUREMENT DATA SHEETS
Page 47 of 72 Report No.: CE01-017
Test Location:
CKC LABORATORIES INC • 110 N. OLINDA PL. • BREA, CA 92823 • 714-993-6112
Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N:
Myricom, Inc. EN55022 A RADIATED 75979 Maximized Emissions Chassis Myricom See List Below See List Below
Date: Time: Sequence#: Tested By:
Equipment Under Test (* = EUT): Function Manufacturer Chassis* Myricom 10BaseT Ethernet Myricom, Inc. monitoring card 8 port fiber Myrinet card Myricom, Inc. 4 port Myrinet LAN card Myricom, Inc. Support Devices: Function Hub Monitor Keyboard Mouse Computer Myrinet 2000 Fiber Optic PCI card
Model # M3-16 M3-M
01/11/2001 11:26:06 1 Stuart Yamamoto
S/N 64652
Spine-8F M3-SW16-4L
Manufacturer Netgear Miracle HP HP HP Myricom, Inc.
Model # FS108 MO935 5129 MS-34 Pavilion 6735 M3F-PCI64B-8
S/N F518E06050651 90052394 F02605917 LZN01904868 KR03109769 63007
Test Conditions / Notes: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. Power-One power supply, MPU150-S259. Voltage to EUT is 235 VAC, 50 Hz, Temperature: 18.5°C, Humidity: 56%. Measurement Data: #
Reading listed by margin. Bicon Log_3 Cable
1
Freq MHz 499.990M
Rdng dBµV 48.5
dB +0.0
dB +16.9
dB +4.4
2
875.012M
40.4
+0.0
+23.0
+5.7
3
874.991M
39.3
+0.0
+23.0
+5.7
4
879.565M
38.8
+0.0
+23.1
+5.7
5
999.998M
36.9
+0.0
+24.3
+6.3
Test Distance: 10 Meters Pream Dist Corr Spec dB Table dBµV/m dBµV/m -28.0 +0.0 41.8 47.0 50 -27.4 +0.0 41.7 47.0 340 -27.4 +0.0 40.6 47.0 344 -27.4 +0.0 40.2 47.0 156 -28.2 +0.0 39.3 47.0 90
Margin dB -5.2 -5.3 -6.4 -6.8 -7.7
Polar Ant Horiz 204 Vert 214 Horiz 100 Horiz 100 Vert 100
Page 48 of 72 Report No.: CE01-017
6
159.979M
40.6
+17.8
+0.0
+2.4
-28.6
7
749.996M
40.4
+0.0
+21.5
+5.2
-28.1
8
999.998M
36.0
+0.0
+24.3
+6.3
-28.2
9
500.012M
45.0
+0.0
+16.9
+4.4
-28.0
10
199.991M
41.1
+16.2
+0.0
+2.4
-28.6
11
143.997M
40.2
+17.0
+0.0
+2.3
-28.6
12
996.506M
34.7
+0.0
+24.3
+6.3
-28.2
13
144.018M
38.9
+17.0
+0.0
+2.3
-28.6
14
79.977M
49.7
+7.0
+0.0
+1.5
-28.6
15
200.018M
39.1
+16.2
+0.0
+2.4
-28.6
16
160.008M
36.1
+17.8
+0.0
+2.4
-28.6
17
480.009M
41.8
+0.0
+16.6
+4.2
-28.1
18
192.019M
37.2
+16.5
+0.0
+2.4
-28.6
19
199.998M
37.4
+16.2
+0.0
+2.4
-28.6
20
480.017M
41.7
+0.0
+16.6
+4.2
-28.1
21
192.002M
36.8
+16.5
+0.0
+2.4
-28.6
22
200.439M
36.4
+16.2
+0.0
+2.4
-28.6
23
827.797M
32.6
+0.0
+22.1
+5.5
24
832.195M
31.8
+0.0
+22.2
25
719.993M
32.5
+0.0
26
95.997M
39.7
27
399.988M
28
400.007M
+0.0 49 +0.0 41 +0.0 35 +0.0 24 +0.0 361 +0.0 361 +0.0 86 +0.0 320 +0.0 119 +0.0 30 +0.0 34 +0.0 65 +0.0 263 +0.0 46 +0.0
32.2
40.0
-7.8
39.0
47.0
-8.0
38.4
47.0
-8.6
38.3
47.0
-8.7
31.1
40.0
-8.9
30.9
40.0
-9.1
37.1
47.0
-9.9
29.6
40.0
-10.4
29.6
40.0
-10.4
29.1
40.0
-10.9
27.7
40.0
-12.3
34.5
47.0
-12.5
27.5
40.0
-12.5
27.4
40.0
-12.6
34.4
47.0
-12.6
27.1
40.0
-12.9
26.4
40.0
-13.6
-27.5
+0.0 167 +0.0 26 +0.0
32.7
47.0
-14.3
+5.5
-27.4
+0.0
32.1
47.0
-14.9
+22.4
+5.1
-28.0
32.0
47.0
-15.0
+10.9
+0.0
+1.7
-28.4
+0.0 175 +0.0
23.9
40.0
-16.1
40.0
+0.0
+15.2
+3.7
-28.1
30.8
47.0
-16.2
39.8
+0.0
+15.2
+3.7
-28.1
+0.0 225 +0.0 1
30.6
47.0
-16.4
Vert 100 Horiz 100 Horiz 204 Vert 237 Vert 100 Vert 100 Vert 100 Vert 353 Vert 100 Vert 100 Vert 327 Vert 196 Vert 100 Vert 158 Horiz 310 Vert 201 Vert 100 Horiz 100 Horiz 100 Vert 100 Vert 100 Horiz 258 Vert 100
Page 49 of 72 Report No.: CE01-017
Test Location:
CKC LABORATORIES INC • 110 N. OLINDA PL. • BREA, CA 92823 • 714-993-6112
Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N:
Myricom, Inc. EN55022 A COND AVG 75979 Conducted Emissions Chassis Myricom See List Below See List Below
Date: Time: Sequence#: Tested By:
Equipment Under Test (* = EUT): Function Manufacturer Chassis* Myricom 10BaseT Ethernet Myricom, Inc. monitoring card 8 port fiber Myrinet card Myricom, Inc. 4 port Myrinet LAN card Myricom, Inc. Support Devices: Function Hub Monitor Keyboard Mouse Computer Myrinet 2000 Fiber Optic PCI card
01/11/2001 17:27:55 2 Stuart Yamamoto
Model # M3-16 M3-M
S/N 64652
Spine-8F M3-SW16-4L
Manufacturer Netgear Miracle HP HP HP Myricom, Inc.
Model # FS108 MO935 5129 MS-34 Pavilion 6735 M3F-PCI64B-8
S/N F518E06050651 90052394 F02605917 LZN01904868 KR03109769 63007
Test Conditions / Notes: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. Power-One power supply, MPU150-S259. Voltage to EUT is 235 VAC, 50 Hz, Temperature: 18.5°C, Humidity: 56%. Measurement Data: #
Reading listed by margin.
Test Lead: Black
1
Freq MHz 191.856k
Rdng dBµV 55.2
2
638.811k
43.1
+0.0
43.1
3
160.775k
49.1
+0.0
4
154.144k
49.0
5
215.478k
47.8
dB
dB
dB
dB
Dist Corr Spec Table dBµV/m dBµV/m +0.0 55.2 66.0
Margin dB -10.8
Polar Ant Black
60.0
-16.9
Black
49.1
66.0
-16.9
Black
+0.0
49.0
66.0
-17.0
Black
+0.0
47.8
66.0
-18.2
Black
Page 50 of 72 Report No.: CE01-017
6
227.081k
47.4
+0.0
47.4
66.0
-18.6
Black
7
150.829k
47.2
+0.0
47.2
66.0
-18.8
Black
8
156.631k
46.9
+0.0
46.9
66.0
-19.1
Black
9
219.622k
46.7
+0.0
46.7
66.0
-19.3
Black
10
164.919k
46.6
+0.0
46.6
66.0
-19.4
Black
11
224.595k
46.0
+0.0
46.0
66.0
-20.0
Black
12
203.874k
45.9
+0.0
45.9
66.0
-20.1
Black
13
166.991k
45.9
+0.0
45.9
66.0
-20.1
Black
14
210.919k
45.1
+0.0
45.1
66.0
-20.9
Black
15
248.631k
43.3
+0.0
43.3
66.0
-22.7
Black
16
245.315k
43.3
+0.0
43.3
66.0
-22.7
Black
17
172.378k
42.9
+0.0
42.9
66.0
-23.1
Black
18
174.036k
42.0
+0.0
42.0
66.0
-24.0
Black
19
233.712k
41.9
+0.0
41.9
66.0
-24.1
Black
20
239.514k
40.5
+0.0
40.5
66.0
-25.5
Black
Page 51 of 72 Report No.: CE01-017
Page 52 of 72 Report No.: CE01-017
Test Location:
CKC LABORATORIES INC • 110 N. OLINDA PL. • BREA, CA 92823 • 714-993-6112
Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N:
Myricom, Inc. EN55022 A COND AVG 75979 Conducted Emissions Chassis Myricom See List Below See List Below
Date: Time: Sequence#: Tested By:
Equipment Under Test (* = EUT): Function Manufacturer Chassis* Myricom 10BaseT Ethernet Myricom, Inc. monitoring card 8 port fiber Myrinet card Myricom, Inc. 4 port Myrinet LAN card Myricom, Inc. Support Devices: Function Hub Monitor Keyboard Mouse Computer Myrinet 2000 Fiber Optic PCI card
01/11/2001 17:32:21 3 Stuart Yamamoto
Model # M3-16 M3-M
S/N 64652
Spine-8F M3-SW16-4L
Manufacturer Netgear Miracle HP HP HP Myricom, Inc.
Model # FS108 MO935 5129 MS-34 Pavilion 6735 M3F-PCI64B-8
S/N F518E06050651 90052394 F02605917 LZN01904868 KR03109769 63007
Test Conditions / Notes: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. Power-One power supply, MPU150-S259. Voltage to EUT is 235 VAC, 50 Hz, Temperature: 18.5°C, Humidity: 56%. Measurement Data: #
Reading listed by margin.
Test Lead: White
1
Freq MHz 191.856k
Rdng dBµV 55.1
2
641.928k
43.2
+0.0
43.2
3
162.432k
48.2
+0.0
4
154.144k
48.2
5
221.279k
48.1
dB
dB
dB
dB
Dist Corr Spec Table dBµV/m dBµV/m +0.0 55.1 66.0
Margin dB -10.9
Polar Ant White
60.0
-16.8
White
48.2
66.0
-17.8
White
+0.0
48.2
66.0
-17.8
White
+0.0
48.1
66.0
-17.9
White
Page 53 of 72 Report No.: CE01-017
6
159.117k
47.5
+0.0
47.5
66.0
-18.5
White
7
156.631k
47.5
+0.0
47.5
66.0
-18.5
White
8
160.775k
47.3
+0.0
47.3
66.0
-18.7
White
9
217.550k
47.0
+0.0
47.0
66.0
-19.0
White
10
215.478k
46.8
+0.0
46.8
66.0
-19.2
White
11
228.739k
45.4
+0.0
45.4
66.0
-20.6
White
12
249.874k
44.1
+0.0
44.1
66.0
-21.9
White
13
209.676k
42.9
+0.0
42.9
66.0
-23.1
White
14
172.378k
42.8
+0.0
42.8
66.0
-23.2
White
15
168.649k
42.8
+0.0
42.8
66.0
-23.2
White
16
255.261k
42.7
+0.0
42.7
66.0
-23.3
White
17
174.036k
42.3
+0.0
42.3
66.0
-23.7
White
18
234.541k
41.8
+0.0
41.8
66.0
-24.2
White
19
236.198k
40.2
+0.0
40.2
66.0
-25.8
White
20
825.838k
33.8
+0.0
33.8
60.0
-26.2
White
Page 54 of 72 Report No.: CE01-017
Page 55 of 72 Report No.: CE01-017
Test Location:
CKC LABORATORIES INC • 110 N. OLINDA PL. • BREA, CA 92823 • 714-993-6112
Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N:
Myricom, Inc. EN55022A [AVG] (Telecom) 75979 Conducted Emissions Chassis Myricom See List Below See List Below
Date: Time: Sequence#: Tested By:
Equipment Under Test (* = EUT): Function Manufacturer Chassis* Myricom 10BaseT Ethernet Myricom, Inc. monitoring card 8 port fiber Myrinet card Myricom, Inc. 4 port Myrinet LAN card Myricom, Inc. Support Devices: Function Hub Monitor Keyboard Mouse Computer Myrinet 2000 Fiber Optic PCI card
01/11/2001 17:41:12 4 Stuart Yamamoto
Model # M3-16 M3-M
S/N 64652
Spine-8F M3-SW16-4L
Manufacturer Netgear Miracle HP HP HP Myricom, Inc.
Model # FS108 MO935 5129 MS-34 Pavilion 6735 M3F-PCI64B-8
S/N F518E06050651 90052394 F02605917 LZN01904868 KR03109769 63007
Test Conditions / Notes: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. Power-One power supply, MPU150-S259. Voltage to EUT is 235 VAC, 50 Hz, Temperature: 18.5°C, Humidity: 56%. Measurement Data: #
Reading listed by margin. TLISN
1
Freq MHz 641.928k
Rdng dBµV 38.2
dB +9.5
2
8.102M
34.8
3
5.785M
4 5
Test Lead: None Dist Table +0.0
Corr dBµV 47.7
Spec dBµV 74.0
Margin dB -26.3
Polar Ant None
+9.5
+0.0
44.3
74.0
-29.7
None
34.7
+9.5
+0.0
44.2
74.0
-29.8
None
12.513M
33.7
+9.5
+0.0
43.2
74.0
-30.8
None
10.308M
33.4
+9.5
+0.0
42.9
74.0
-31.1
None
dB
dB
dB
Page 56 of 72 Report No.: CE01-017
6
6.189M
33.1
+9.5
+0.0
42.6
74.0
-31.4
None
7
14.762M
32.2
+9.5
+0.0
41.7
74.0
-32.3
None
8
832.072k
31.9
+9.5
+0.0
41.4
74.0
-32.6
None
9
6.676M
31.7
+9.5
+0.0
41.2
74.0
-32.8
None
10
1.898M
31.7
+9.5
+0.0
41.2
74.0
-32.8
None
11
9.866M
31.1
+9.5
+0.0
40.6
74.0
-33.4
None
12
7.479M
31.1
+9.5
+0.0
40.6
74.0
-33.4
None
13
5.861M
31.1
+9.5
+0.0
40.6
74.0
-33.4
None
14
9.073M
31.0
+9.5
+0.0
40.5
74.0
-33.5
None
15
7.303M
31.0
+9.5
+0.0
40.5
74.0
-33.5
None
16
13.615M
30.8
+9.5
+0.0
40.3
74.0
-33.7
None
17
7.584M
30.8
+9.5
+0.0
40.3
74.0
-33.7
None
18
24.708M
30.7
+9.5
+0.0
40.2
74.0
-33.8
None
19
1.081M
30.7
+9.5
+0.0
40.2
74.0
-33.8
None
20
1.191M
30.6
+9.5
+0.0
40.1
74.0
-33.9
None
Page 57 of 72 Report No.: CE01-017
Page 58 of 72 Report No.: CE01-017
Test Location:
CKC LABORATORIES INC • 110 N. OLINDA PL. • BREA, CA 92823 • 714-993-6112
Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N:
Myricom, Inc. CISPR22 A COND AVE 75979 Conducted Emissions Chassis Myricom See List Below See List Below
Date: Time: Sequence#: Tested By:
Equipment Under Test (* = EUT): Function Manufacturer Chassis* Myricom 10BaseT Ethernet Myricom, Inc. monitoring card 8 port fiber Myrinet card Myricom, Inc. 4 port Myrinet LAN card Myricom, Inc. Support Devices: Function Hub Monitor Keyboard Mouse Computer Myrinet 2000 Fiber Optic PCI card
01/11/2001 17:13:12 5 Stuart Yamamoto
Model # M3-16 M3-M
S/N 64652
Spine-8F M3-SW16-4L
Manufacturer Netgear Miracle HP HP HP Myricom, Inc.
Model # FS108 MO935 5129 MS-34 Pavilion 6735 M3F-PCI64B-8
S/N F518E06050651 90052394 F02605917 LZN01904868 KR03109769 63007
Test Conditions / Notes: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. Power-One power supply, MPU150-S259. Voltage to EUT is 110 VAC, 60 Hz, Temperature: 18.5°C, Humidity: 56%. Measurement Data: #
Reading listed by margin.
Test Lead: Black
1
Freq MHz 191.856k
Rdng dBµV 56.6
2
203.874k
51.0
+0.0
51.0
3
156.631k
50.3
+0.0
4
150.829k
49.8
5
208.847k
49.2
dB
dB
dB
dB
Dist Corr Spec Table dBµV/m dBµV/m +0.0 56.6 66.0
Margin dB -9.4
Polar Ant Black
66.0
-15.0
Black
50.3
66.0
-15.7
Black
+0.0
49.8
66.0
-16.2
Black
+0.0
49.2
66.0
-16.8
Black
Page 59 of 72 Report No.: CE01-017
6
221.279k
49.0
+0.0
49.0
66.0
-17.0
Black
7
213.820k
49.0
+0.0
49.0
66.0
-17.0
Black
8
210.505k
48.9
+0.0
48.9
66.0
-17.1
Black
9
218.793k
48.7
+0.0
48.7
66.0
-17.3
Black
10
163.261k
48.6
+0.0
48.6
66.0
-17.4
Black
11
171.550k
47.4
+0.0
47.4
66.0
-18.6
Black
12
173.207k
47.3
+0.0
47.3
66.0
-18.7
Black
13
179.838k
47.1
+0.0
47.1
66.0
-18.9
Black
14
176.523k
46.3
+0.0
46.3
66.0
-19.7
Black
15
638.811k
39.0
+0.0
39.0
60.0
-21.0
Black
16
232.883k
44.6
+0.0
44.6
66.0
-21.4
Black
17
255.261k
43.8
+0.0
43.8
66.0
-22.2
Black
18
241.171k
42.0
+0.0
42.0
66.0
-24.0
Black
19
246.973k
41.7
+0.0
41.7
66.0
-24.3
Black
20
832.072k
34.1
+0.0
34.1
60.0
-25.9
Black
Page 60 of 72 Report No.: CE01-017
Page 61 of 72 Report No.: CE01-017
Test Location:
CKC LABORATORIES INC • 110 N. OLINDA PL. • BREA, CA 92823 • 714-993-6112
Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N:
Myricom, Inc. CISPR22 A COND AVE 75979 Conducted Emissions Chassis Myricom See List Below See List Below
Date: Time: Sequence#: Tested By:
Equipment Under Test (* = EUT): Function Manufacturer Chassis* Myricom 10BaseT Ethernet Myricom, Inc. monitoring card 8 port fiber Myrinet card Myricom, Inc. 4 port Myrinet LAN card Myricom, Inc. Support Devices: Function Hub Monitor Keyboard Mouse Computer Myrinet 2000 Fiber Optic PCI card
01/11/2001 17:15:27 6 Stuart Yamamoto
Model # M3-16 M3-M
S/N 64652
Spine-8F M3-SW16-4L
Manufacturer Netgear Miracle HP HP HP Myricom, Inc.
Model # FS108 MO935 5129 MS-34 Pavilion 6735 M3F-PCI64B-8
S/N F518E06050651 90052394 F02605917 LZN01904868 KR03109769 63007
Test Conditions / Notes: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. Power-One power supply, MPU150-S259. Voltage to EUT is 110 VAC, 60 Hz, Temperature: 18.5°C, Humidity: 56%. Measurement Data: #
Reading listed by margin.
Test Lead: White
1
Freq MHz 191.441k
Rdng dBµV 56.2
2
159.117k
50.6
+0.0
50.6
3
204.288k
50.4
+0.0
4
162.432k
50.2
5
160.775k
50.2
dB
dB
dB
dB
Dist Corr Spec Table dBµV/m dBµV/m +0.0 56.2 66.0
Margin dB -9.8
Polar Ant White
66.0
-15.4
White
50.4
66.0
-15.6
White
+0.0
50.2
66.0
-15.8
White
+0.0
50.2
66.0
-15.8
White
Page 62 of 72 Report No.: CE01-017
6
208.018k
50.1
+0.0
50.1
66.0
-15.9
White
7
638.811k
43.9
+0.0
43.9
60.0
-16.1
White
8
151.658k
49.5
+0.0
49.5
66.0
-16.5
White
9
221.279k
49.3
+0.0
49.3
66.0
-16.7
White
10
216.306k
48.3
+0.0
48.3
66.0
-17.7
White
11
173.207k
47.6
+0.0
47.6
66.0
-18.4
White
12
179.009k
47.4
+0.0
47.4
66.0
-18.6
White
13
169.063k
47.4
+0.0
47.4
66.0
-18.6
White
14
232.054k
45.1
+0.0
45.1
66.0
-20.9
White
15
237.027k
44.9
+0.0
44.9
66.0
-21.1
White
16
254.018k
44.2
+0.0
44.2
66.0
-21.8
White
17
243.243k
42.4
+0.0
42.4
66.0
-23.6
White
18
832.072k
33.9
+0.0
33.9
60.0
-26.1
White
19
22.083M
33.2
+0.0
33.2
60.0
-26.8
White
20
9.911M
33.2
+0.0
33.2
60.0
-26.8
White
Page 63 of 72 Report No.: CE01-017
Page 64 of 72 Report No.: CE01-017
Test Location:
CKC LABORATORIES INC • 110 N. OLINDA PL. • BREA, CA 92823 • 714-993-6112
Customer: Specification: Work Order #: Test Type: Equipment: Manufacturer: Model: S/N:
Myricom, Inc. FCC A RADIATED 75979 Maximized Emissions Chassis Myricom See List Below See List Below
Date: Time: Sequence#: Tested By:
Equipment Under Test (* = EUT): Function Manufacturer Chassis* Myricom 10BaseT Ethernet Myricom, Inc. monitoring card 8 port fiber Myrinet card Myricom, Inc. 4 port Myrinet LAN card Myricom, Inc. Support Devices: Function Hub Monitor Keyboard Mouse Computer Myrinet 2000 Fiber Optic PCI card
Model # M3-16 M3-M
01/11/2001 12:56:10 1 Stuart Yamamoto
S/N 64652
Spine-8F M3-SW16-4L
Manufacturer Netgear Miracle HP HP HP Myricom, Inc.
Model # FS108 MO935 5129 MS-34 Pavilion 6735 M3F-PCI64B-8
S/N F518E06050651 90052394 F02605917 LZN01904868 KR03109769 63007
Test Conditions / Notes: The EUT is placed stand alone on the wooden table. All Myrinet 2000 ports filled. Both ethernet ports (RJ45 UTP green for St. Patrick’s Day) connected to remotely located hub which is connected to the computer. Four LAN ports and eight fiber communication ports all connected in loop back. The source data is created from the remotely located computer and sent to the EUT and the data is received from the switch to the M3F-PCI64-8 PCI card. Frequency range scanned and maximized, 1-6.25 GHz. Power-One power supply, MPU150-S259. Voltage to EUT is 110 VAC, 60 Hz, Temperature: 18.5°C, Humidity: 56%. Measurement Data: #
Reading listed by margin. Cable Cable 83017
Freq Rdng MHz dBµV 1 2499.973M 47.9
dB +5.0
dB +0.7
dB -37.8
2 5000.015M
45.7
+7.4
-0.6
-41.1
3 2124.990M
51.5
+4.5
+0.6
-39.8
4 2249.989M
50.0
+4.6
+0.6
-39.1
5 2000.027M
53.0
+4.3
+0.6
-40.5
Test Distance: 10 Meters Horn Dist Corr Spec dB Table dBµV/m dBµV/m +28.7 +0.0 44.5 49.5 326 +32.9 +0.0 44.3 49.5 14 +26.9 +0.0 43.7 49.5 358 +27.5 +0.0 43.6 49.5 13 +26.2 +0.0 43.6 49.5 1
Margin dB -5.0 -5.2 -5.8 -5.9 -5.9
Polar Ant Horiz 100 Horiz 141 Vert 122 Vert 100 Vert 125
Page 65 of 72 Report No.: CE01-017
6 1749.960M
54.3
+4.1
+0.6
-40.5
+24.9
7 1749.998M
54.3
+4.1
+0.6
-40.5
+24.9
8 1500.078M
56.2
+3.7
+0.4
-40.5
+23.5
9 5000.019M
44.4
+7.4
-0.6
-41.1
+32.9
10 1249.865M
57.8
+3.4
+0.4
-41.3
+22.6
11 1875.005M
52.9
+4.2
+0.5
-40.5
+25.6
12 1375.022M
56.6
+3.6
+0.4
-40.9
+23.0
13 1125.001M
58.5
+3.2
+0.4
-41.7
+22.0
14 1312.439M
56.4
+3.5
+0.4
-41.1
+22.8
15 1624.984M
52.8
+3.9
+0.5
-40.5
+24.3
16 1999.993M
50.3
+4.3
+0.6
-40.5
+26.2
17 2500.064M Ave ^ 2500.016M
43.6
+5.0
+0.7
-37.8
+28.7
51.6
+5.0
+0.7
-37.8
+28.7
19 1000.046M
57.1
+3.2
+0.4
-42.2
+21.4
20 3625.058M Ave ^ 3625.016M
37.8
+6.0
+0.6
-39.0
+32.6
47.5
+6.0
+0.6
-39.0
+32.6
22 1124.969M
54.0
+3.2
+0.4
-41.7
+22.0
23 1003.427M
54.3
+3.2
+0.4
-42.2
+21.4
24 2999.985M Ave ^ 3000.004M
37.2
+5.5
+0.7
-38.4
+31.4
45.8
+5.5
+0.7
-38.4
+31.4
26 2999.974M Ave ^ 2999.995M
37.1
+5.5
+0.7
-38.4
+31.4
47.1
+5.5
+0.7
-38.4
+31.4
28 1000.024M
52.6
+3.2
+0.4
-42.2
+21.4
+0.0 322 +0.0 1 +0.0 15 +0.0 14 +0.0 50 +0.0 358 +0.0 117 +0.0 75 +0.0 44 +0.0 358 +0.0 21 +0.0 -1 +0.0 -1 +0.0 90 +0.0 346 +0.0 346 +0.0 50 +0.0 81 +0.0 13 +0.0 13 +0.0 345 +0.0 345 +0.0 303
43.4
49.5
-6.1
43.4
49.5
-6.1
43.3
49.5
-6.2
43.0
49.5
-6.5
42.9
49.5
-6.6
42.7
49.5
-6.8
42.7
49.5
-6.8
42.4
49.5
-7.1
42.0
49.5
-7.5
41.0
49.5
-8.5
40.9
49.5
-8.6
40.2
49.5
-9.3
48.2
49.5
-1.3
39.9
49.5
-9.6
38.0
49.5
-11.5
47.7
49.5
-1.8
37.9
49.5
-11.6
37.1
49.5
-12.4
36.4
49.5
-13.1
45.0
49.5
-4.5
36.3
49.5
-13.2
46.3
49.5
-3.2
35.4
49.5
-14.1
Horiz 116 Vert 100 Vert 234 Vert 100 Vert 103 Vert 137 Vert 123 Vert 100 Vert 100 Vert 100 Horiz 226 Vert 117 Vert 117 Vert 141 Horiz 127 Horiz 127 Horiz 100 Vert 116 Vert 148 Vert 148 Horiz 162 Horiz 162 Horiz 100
Page 66 of 72 Report No.: CE01-017
Page 67 of 72 Report No.: CE01-017
Page 68 of 72 Report No.: CE01-017
Page 69 of 72 Report No.: CE01-017
Page 70 of 72 Report No.: CE01-017
Page 71 of 72 Report No.: CE01-017
Page 72 of 72 Report No.: CE01-017