Transcript
BOSS DB Series IC502
IC504 C516
C517 HALLS 60/120
SW502
C501
TB504
FAULT IL502
SO501 TACH IN
C4
C501 R501
IC507
IC501
+BUS
C507
C501
C508
C50
TH501 BUS LIMIT
SW501
C512
AC1
REV FWD MAXSPD ACCEL
DECEL
MIN SPD
IR COMP
FWD REV TQLIM
OS
1.75 [44] 1
GA
1
L2
BR501
T501
* FUSE
Emergency Stop Switch
BOSS SERIES DRIVE
0.73 [18]
115 or 230 VAC
BOSS DB SERIES REGEN DUMP CIRCUIT
or 100 - 320 VDC FUSE
NOTE:
3.64 [92]
TB502
L501
L1
MODE
TP1
AC2
BOSSDB
www.minarikdrives.com MINARIK DRIVES South Beloit, IL 61080 -- u.S.A.
-VDC
C513
C511
C510 C518 C509
+VDC
-BUS
PWR ON IL501
IL501
-BUS
+BUS
BOSSDB
C501
C4
QC503 QC502
www.minarikdrives.com MINARIK DRIVES South Beloit, IL 61080 -- u.S.A.
C515
2.45 [62]
Connect POS (+) to L1 and COM (-) to L2 when using a DC power source.
1.60 [40]
1.28 [33]
* NOTE: Do not add fuse to L2 unless input voltage is 230 VAC.
BOSSDB Series Regen Dump Circuit Connections
3.80 [97] 4.30 [109]
Regen Dump Circuit Connections
DC Power Source Connections
The regen dump circuit is recommended for all BOSS Series drives. Regenerative loads may cause the bus voltage to increase. The regen dump circuit prevents the voltage across the bus capacitors from exceeding their voltage rating.
If you use a DC power source with the regen dump circuit, you must connect the power source to the BOSS drive L1 and L2 terminals as shown in the figure above.
1. Connect the +BUS terminal on the regen dump circuit to the +VDC terminal on the BOSS drive motherboard. 2. Connect the -BUS terminal on the regen dump circuit to the -VDC terminal on the BOSS drive motherboard.
BOSSDB Series Regen Dump Circuit Dimensions All dimensions in Inches [Millimeters]
1. Connect the positive (+) lead from the DC power source to the L1 terminal on the BOSS drive motherboard. 2. Connect the negative (or COM) lead from the DC power source to the L2 terminal on the BOSS drive motherboard.
Copyright 2006 by Minarik Drives - All rights reserved. No part of this manual may be reproduced or transmitted in any form without written permission from Minarik Drives. The information and technical data in this manual are subject to change without notice. Minarik Corporation and its Divisions make no warranty of any kind with respect to this material, including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. Minarik Corporation and its Divisions assume no responsibility for any errors that may appear in this manual and make no commitment to update or to keep current the information in this manual.
MINARIK DRIVES www.minarikdrives.com Phone: (800) MINARIK (646-2745); Fax: (800) 394-6334 Document Number 250-0328, Revision 2; Printed in the U.S.A. – June 2006