Preview only show first 10 pages with watermark. For full document please download

250 0328

   EMBED


Share

Transcript

BOSS DB Series IC502 IC504 C516 C517 HALLS 60/120 SW502 C501 TB504 FAULT IL502 SO501 TACH IN C4 C501 R501 IC507 IC501 +BUS C507 C501 C508 C50 TH501 BUS LIMIT SW501 C512 AC1 REV FWD MAXSPD ACCEL DECEL MIN SPD IR COMP FWD REV TQLIM OS 1.75 [44] 1 GA 1 L2 BR501 T501 * FUSE Emergency Stop Switch BOSS SERIES DRIVE 0.73 [18] 115 or 230 VAC BOSS DB SERIES REGEN DUMP CIRCUIT or 100 - 320 VDC FUSE NOTE: 3.64 [92] TB502 L501 L1 MODE TP1 AC2 BOSSDB www.minarikdrives.com MINARIK DRIVES South Beloit, IL 61080 -- u.S.A. -VDC C513 C511 C510 C518 C509 +VDC -BUS PWR ON IL501 IL501 -BUS +BUS BOSSDB C501 C4 QC503 QC502 www.minarikdrives.com MINARIK DRIVES South Beloit, IL 61080 -- u.S.A. C515 2.45 [62] Connect POS (+) to L1 and COM (-) to L2 when using a DC power source. 1.60 [40] 1.28 [33] * NOTE: Do not add fuse to L2 unless input voltage is 230 VAC. BOSSDB Series Regen Dump Circuit Connections 3.80 [97] 4.30 [109] Regen Dump Circuit Connections DC Power Source Connections The regen dump circuit is recommended for all BOSS Series drives. Regenerative loads may cause the bus voltage to increase. The regen dump circuit prevents the voltage across the bus capacitors from exceeding their voltage rating. If you use a DC power source with the regen dump circuit, you must connect the power source to the BOSS drive L1 and L2 terminals as shown in the figure above. 1. Connect the +BUS terminal on the regen dump circuit to the +VDC terminal on the BOSS drive motherboard. 2. Connect the -BUS terminal on the regen dump circuit to the -VDC terminal on the BOSS drive motherboard. BOSSDB Series Regen Dump Circuit Dimensions All dimensions in Inches [Millimeters] 1. Connect the positive (+) lead from the DC power source to the L1 terminal on the BOSS drive motherboard. 2. Connect the negative (or COM) lead from the DC power source to the L2 terminal on the BOSS drive motherboard. Copyright 2006 by Minarik Drives - All rights reserved. No part of this manual may be reproduced or transmitted in any form without written permission from Minarik Drives. The information and technical data in this manual are subject to change without notice. Minarik Corporation and its Divisions make no warranty of any kind with respect to this material, including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. Minarik Corporation and its Divisions assume no responsibility for any errors that may appear in this manual and make no commitment to update or to keep current the information in this manual. MINARIK DRIVES www.minarikdrives.com Phone: (800) MINARIK (646-2745); Fax: (800) 394-6334 Document Number 250-0328, Revision 2; Printed in the U.S.A. – June 2006