Preview only show first 10 pages with watermark. For full document please download

2.5“ Sata Ii Ssd

   EMBED


Share

Transcript

  2.5“ SATA II SSD Orion1200 Enterprise SSD Series  Model:  UGB88PGCXXXXXX  The Unigen 2.5” Orion Series of Solid State Drives are designed specifically to address Enterprise storage and computing applications where demanding performance, reliability, and the total cost of ownership (TCO) are major factors.   Solution Datasheet UGB88PGCXXXXXX Solutions for a Real Time World     Revision History  Rev.  Date  By    Reason For Change  0.1  9/15/10  Engineering  Initial draft  0.2  9/20/10  Product Management  Minor edits and formatting  1.0  10/01/10  Product Management  Initial Release  2.0  3/01/11  Product Management  Added 60GB Density          2  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World     Unigen Orion 2.5” SATA Solid State Drive  Part Number  UGB88PGC60H0xx  UGB88PGC100Hxx  UGB88PGC120Hxx  UGB88PGC200Hxx  UGB88PGC240Hxx  Description  Unigen Orion 2.5” SATAII   60GB MLC  Unigen Orion 2.5” SATAII 100GB MLC  Unigen Orion 2.5” SATAII 120GB MLC  Unigen Orion 2.5” SATAII 200GB MLC  Unigen Orion 2.5” SATAII 240GB MLC  Status  Active  Active  Active  Active  Active  3  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World     Product Specifications           Available in 2.5” Form Factor  Capacity:  60GB, 100GB, 120GB,  200GB and 240GB  Uses NAND Multi‐Level Cell (MLC) components  AES 128‐bit encryption.  Bandwidth Performance Specifications   o Maximum Sequential Read:   Up to 285 MB/s  o Maximum Sequential Write:   Up to 275 MB/s  Read and Write IOPS specifications  o Random 4Kb Reads:  Up to 30,000 IOPS  o Random 4Kb Writes:  Up to 10,000 IOPS  Compatibility  o SATA Revision 2.6 compliant,  compatible with SATA 1.5 GB/s and  3 GB/s interface rates  o ATA/ATAPI‐7 Compliant  o ATA‐8 Compliant  o SSD Enhanced SMART ATA feature set  o Native Command Queuing (NCQ)  command  Power Management  o 5 V SATA Supply Rail  o Supports ATA Power Management and  Advanced Power Management  Specifications  o SATA Interface Power Management  o OS‐Aware Hot Plug/Removal             Power Specifications  o Active (typical): 1.5 W  o Idle (typical): 0.5 W  Temperature  o Operating: 0°C to 70°C  o Non‐Operating: ‐10°C to 85°C  Reliability   o Mean Time Between Failures (MTBF)  1,500,000 Hours  Shock  o Operating: 1,500G. Duration 0.5ms,  half sine wave  Vibration  o 20G. Peak, 10 ~ 20KHz with 3 axis  Weight:  o 0.22 Pounds  Altitude:  o 80,000 ft. Max  Acoustic Noise:  o 0 db  Humidity:  o 5% to 95% , non‐condensing  Data Reliability:  o 1 in 1017 bits, Read  Data Retention:  o 10 Years  Compliance  o FCC  o RoHS      4  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World   Ordering Information                 UG                    B88                  PGC                        XXXX                                 XX    Unigen  Type of Product  B88 = 2.5 inch SATA SSD  Assembly Code  PGC = 2.5 inch SATA, MLC    Density 60H0 =   60GB  100H = 100GB  120H = 120GB  200H = 200GB   240H = 240GB  PGC Firmware   F1= MLC SATA  Ver 1.0 (MP1)   F2= MLC SATA  Ver 2.0 (MP2)   F3= MLC SATA  Ver 3.0 (MP3)     F4= MLC SATA  Ver 4.0 (MP4)    5  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World   Table of Contents  Unigen Orion 2.5” SATA Solid State Drive .................................................................................................... 3 Product Specifications................................................................................................................................... 4 Ordering Information .................................................................................................................................... 5 Table of Contents .......................................................................................................................................... 6 1. Introduction .......................................................................................................................................... 8 1.1 Product Overview .................................................................................................................... 8 1.2 Block Diagram .......................................................................................................................... 8 1.3 Architecture ............................................................................................................................. 9 2. Certifications and Compliance .............................................................................................................. 9 3. Product Specifications ........................................................................................................................... 9 3.1. Capacity .................................................................................................................................. 9 3.2. Performance ......................................................................................................................... 10 4. Electrical Specifications ....................................................................................................................... 11 5. Environmental Specifications .............................................................................................................. 12 5.1.1. Temperature ....................................................................................................................... 12 5.1.2. Altitude ................................................................................................................................ 12 5.1.3. Shock and Vibration ............................................................................................................ 12 5.1.4. Acoustics ............................................................................................................................. 12 5.1.5. Emissions ............................................................................................................................. 13 5.2. Reliability .............................................................................................................................. 13 5.2.1. Mean Time Between Failures ............................................................................................. 13 5.2.2. Program Erase Cycles .......................................................................................................... 14 5.2.3. ECC ...................................................................................................................................... 14 5.3. Performance Optimization ................................................................................................... 14 5.3.1. TRIM .................................................................................................................................... 14 5.4. Compression and De‐Duplication ......................................................................................... 14 5.5. Encryption ............................................................................................................................. 14 6  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World   6. Mechanical Specifications ................................................................................................................... 15 7. Pin and Signal Descriptions ................................................................................................................. 17 7.1. Hot Plug Support ................................................................................................................... 17 7.2. Signal Description Table ........................................................................................................ 17 8. Glossary ............................................................................................................................................... 19 Appendix ..................................................................................................................................................... 20 A. ATA Support ............................................................................................................................. 20 A.1. The supported ATA Features are: ......................................................................................... 20 A.2. Identify Device Parameters .................................................................................................. 21 B. SMART ..................................................................................................................................... 24 B.1. SMART Subcommand Sets .................................................................................................... 24 B.2.  SMART Read Data ................................................................................................................. 24 C. Contact Information ................................................................................................................ 27     7  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World     1. Introduction  The Unigen Orion Series of Solid State Drives is designed specifically to address the demanding  performance and reliability requirements of Enterprise‐Class storage and computing  applications.  1.1 Product Overview  Built with a SandForce 1222 controller, the Unigen Orion Series SSD is ideal for energy‐efficient  computing, reducing access times, and provides a durable alternative to conventional hard disc  drives with superior shock resistance.  The proprietary space manager architecture in the  controller maximizes read/write data rate performance to and from the host and flash memory,  eliminating firmware delays during sector read and write operations.  The SandForce flash  processor, combined with tailored firmware, provides complete ATA disk emulation, which  ensures complete compatibility with a wide range of operating systems.  Designed for ultimate  reliability, Unigen Orion Series SSD’s have an excellent 1.5 million hour mean time before failure  (MTBF) ensuring reliability over long term usage and come backed by a 3‐year warranty and  dedicated technical and engineering support for OEM clients.  1.2 Block Diagram    8  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World   1.3 Architecture    The Unigen Orion Series SSD’s are designed to fully utilize the SATA II 3.0 Gbps bus and the 16  byte wide lanes of NAND Flash.    2. Certifications and Compliance  Certification/Compliance  Description  FCC Class A devices are those that are for use in a commercial,  Industrial or business environment.  FCC Compliant A  RoHS Compliant  Restriction of Hazardous Substance Directive    3. Product Specifications  3.1. Capacity  Raw Capacity    64GB  128GB  128GB  256GB  256GB  Usable Capacity    60GB 100GB 120GB 200GB 240GB Total User Addressable Sectors in LBA Mode  117,231,408  195,371,568  234,441,648  390,721,968  468,862,128    Notes:     Partitioned and formatted capacity in Microsoft Windows  1 GB = 1,000,000,000 bytes  1 Sector = 512 Byte.  9  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World     3.2. Performance  Maximum Read, Write, and Sustained Write Bandwidth (MB/s)  Metric  Max Read  Max Write  Sustained Write  60GB MLC  285MB/s  275MB/s  270MB/s  100GB MLC  285MB/s  275MB/s  270MB/s  120GB MLC  285MB/s  275MB/s  270MB/s  200GB MLC  285MB/s  275MB/s  270MB/s  240GB MLC  285MB/s  275MB/s  270MB/s  200GB MLC  30,000  10,000  240GB MLC  30,000  10,000      Maximum 4K Random IO/second (IOPS) Metric  4Kb Random Read  4Kb Random  Write    60GB MLC  30,000  10,000  100GB MLC  30,000  10,000  120GB MLC  30,000  10,000  10  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World   4. Electrical Specifications  The SSD interface complies with the following standards:         • SATA Rev. 2.6 specification (SATA I / II )  4.1. Supply Voltage  Description  Operating Voltage for 5 V (+/‐ 8%)      Min  4.60  Max  5.40  Unit  V    4.2. Absolute Maximum Ratings  Parameters  Symbol  Input Voltage  Current  Min  Vcc l    ‐0.3 Max       6.5       1  Unit  V A NOTE:  Stress above those listed under Absolute Maximum Ratings may cause permanent  damage to the device. This is a stress rating only and functional operation of the device at these or  any conditions above those indicated in the operational sections of this specification is not implied.   Exposure to absolute maximum rating conditions for extended periods may affect device reliability.    4.3. Electrical Characteristics  Parameters  Supply Voltage  Operating Current  Idle Current  TX Differential Output Voltage  TX AC Common Mode Voltage  RX Differential Input Voltage  RX AC Common Mode Voltage  Symbol  Vcc Iact Iidl VdiffTx Vcm.acTx VdiffRx Vcm.acTx Min     4.6 Typical      5   290mA   100mA    500 Max     5.4     50     400    150  Unit  Test  V  mA  mA  mVppd  mVp‐p  mVppd  mVp‐p      11  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World   5. Environmental Specifications  5.1.1. Temperature    Ambient  Temperature  Mode  Operating  Non‐Operating  Min  0  ‐10  Max  +70  +85  Unit  o C  o C    5.1.2. Altitude  The drive is not sensitive to changes in altitude because it has no moving parts.  Drive tested up to 80,000 feet.  5.1.3. Shock and Vibration  Operating:  Vibration:    1,500G. Duration 0.5ms, half sine wave  20G. Peak, 10 ~ 20 KHz with 3 axis  5.1.4. Acoustics  The drive has no moving or noise‐emitting parts.  Therefore, it produces no audible sound (0 dB) in all modes of operation.  12  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World     5.1.5. Emissions  The Unigen Orion Series SSD’s are compliant to the FCC regulations.  Standards  FCC § 15.107  FCC § 15.109    Description  Conducted Emissions  Radiated Emissions  Results  Compliant  Compliant  5.2. Reliability  Parameter  MTBF  Program Erase Cycles (P/E)  ECC  Value  1,500,000 Hours  5,000 Cycles  Up to twelve 9 bit symbols per 512 bytes of data    5.2.1. Mean Time between Failures  The Mean Time between Failures (MTBF) is calculated based on a Part Stress Analysis. It  assumes nominal voltage, with all other parameters within specified range.  This  specification is based on the MTBF rating of the SandForce 1222 controller  13  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World   5.2.2.Program Erase Cycles  Specifies the maximum number of cycles the NAND flash chips can be programmed and  erased before losing their ability to hold a charge.  5.2.3.ECC  Error‐Correcting Code defines the number of correctable symbols for a given size of data.    5.3. Performance Optimization  Parameter  TRIM  Value  Non Deterministic TRIM support    5.3.1.TRIM  ATA8 Command that provides for the operating system to inform the drive when sectors  no longer contain valid data   Note: TRIM support requires operating system support.  5.4. Compression and De‐Duplication  Drives use both Compression and De‐Duplication to improve performance and reduce  wear on flash chips.  5.5. Encryption  Orion drives use AES 128‐bit encryption on all data.  User key is not enabled by default,  but data is encrypted at all times for Self Encrypting Device (SED).  14  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World     6. Mechanical Specifications  Parameter  Length  Width  Height  Value  99.9 mm  69.6 mm  9.3 mm    Notes:   All dimensions are in millimeters  15  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World                           Figure 5‐1b   2.5 inch SATA SSD mechanical drawing  16  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World     7. Pin and Signal Descriptions  This section identifies the pin locations and signal descriptions of the Unigen High Performance  SSD’s. The Host is connected to the SSD with a standard 22‐pin SATA connector.    Pin Locations            7.1. Hot Plug Support  Hot Plug insertion and removal are supported in the presence of a proper connector and  appropriate operating system (OS) support as described in the SATA 2.6 specification. This  product supports Asynchronous Signal Recovery and will issue an unsolicited COMINIT when  first mated with a powered connector to guarantee reliable detection by a host system without  hardware device detection.    7.2. Signal Description Table    No.  Plug Connector pin definition S1  GND  S2  A+  S3  A‐  S4  GND  S5  B‐  S6  B+  nd 2 mate Differential signal A from PHY  Signal  nd 2 mate Differential signal B from PHY  17  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World S7  GND    nd 2 mate Key and spacing separate signal and power segments  Power  P1  V33  3.3V power (Unused) P2  V33  3.3V power (Unused) P3  V33  3.3V power, pre‐charge, 2 mate (Unused) P4  GND  1 mate P5  GND  2 mate P6  GND  2 mate P7  V5  5V power, pre‐charge, 2 mate P8  V5  5V power P9  V5  5V power P10  GND  2 mate P11  DAS/DSS  Device Activity Signal  P12  GND  1 mate P13  V12  12V power, pre‐charge, 2 mate (Unused) P14  V12  12V power (Unused) P15  V12  12V power (Unused) nd st nd nd nd nd st nd   18  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World     8. Glossary  Term  ATA  ATAPI  DMA  ECC  EXT  GB  GC  HDD  Hot Plug  IOPS  LBA  MB  MTBF  NCQ  NOP  OS  Port  P/E  SAS  SATA  SFF  SMART  SSD  TRIM    Definition  Advanced Technology Attachment  Advanced Technology Attachment Packet Interface  Direct Memory Access  Error‐Correcting Code  Extended  Giga‐byte defined as 1x109 bytes  Garbage Collection, can be real time or idle time (background)  Hard Disk Drive  A term used to describe the removal or insertion of a SATA hard drive when the  system is powered on.  Input output operations per second  Logical Block Address  Mega‐byte defined as 1x106 bytes  Mean time between failures  Native Command Queuing. The ability of the SATA hard drive to queue and re‐order  commands to maximize execution efficiency.  No Operation  Operating System  The point at which a SATA drive physically connects to the SATA controller.  Program / Erase cycles, defines NAND lifecycle  Serial Attached SCSI  Serial ATA  Small Form Factor  Self‐Monitoring, Analysis and Reporting Technology: an open standard for developing  hard drives and software systems that automatically monitors a hard drive’s health  and reports potential problems.  Solid State Drive  ATA8 Command informing the drive when sectors no longer contain valid data   19  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World   Appendix  A. ATA Support  A.1. The Unigen Orion family of drives complies with all ATA‐8 commands as well as many optional  ones.  The supported ATA Features are:  Feature  ATA‐8 Reference  4.2  4.4  4.8  4.10  4.11  4.15  4.18  4.19  4.20  4.21  4.22  General  48‐bit address   Device configuration overlay (DCO)   General purpose logging (GPL)   Hot protected area (HPA)   Native command queuing (NCQ)   Power management   Power‐up in standby (PUIS)   Security   S.M.A.R.T.   Software setting preservation  (SSP)     Command Name  CHECK POWER MODE   DEVICE CONFIGURATION  FREEZE LOCK   DEVICE CONFIGURATION  IDENTIFY   DEVICE CONFIGURATION  RESTORE   DEVICE CONFIGURATION SET   DOWNLOAD MICROCODE   EXECUTE DEVICE  DIAGNOSTIC   FLUSH CACHE   FLUSH CACHE EXT   IDENTIFY DEVICE   IDLE   Command Code (Hex)  E5h or 98h   B1h/C1h   Command Name  SET FEATURES, SETF  SET MAX ADDRESS   Command Code (Hex)  EFh  F9h  B1h/C2h   SET MAX FREEZE LOCK   F9h/04h   B1h/C0h   SET MAX LOCK   F9h/02h   B1h/C3h   92h   90h   SET MAX SET PASSWORD   SET MAX UNLOCK   SET MAX ADDRESS EXT   F9h/01h   F9h/03h   37h   E7h   EAh   ECh   E3h or 97h   C6h   E6h or 99h   ‐   B0h/D9h   IDLE IMMEDIATE   E1h or 95h   INITIALIZE DEVICE  PARAMETERS   NOP   READ BUFFER   91h   READ DMA   C8h   SET MULTIPLE MODE   SLEEP   SMART   SMART DISABLE  OPERATIONS   SMART ENABLE/DISABLE  AUTO OFF‐LINE  SMART ENABLE/DISABLE  AUTOSAVE  SMART ENABLE OPERATIONS  SMART EXECUTE OFF‐LINE  IMMIDIATE   SMART READ DATA   00h/00h   E4h   B0h/‐DBh  B0h‐D2  B0h/D8h   B0h/D4h   B0h/D0h   20  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World READ DMA EXT   READ FPDMA QUEUED   READ LOG EXT   READ LOG DMA EXT  25h   60h   2Fh   47h  READ MULTIPLE   READ MULTIPLE EXT   READ NATIVE MAX ADDRESS   READ NATIVE MAX ADDRESS  EXT   READ SECTOR(S)   READ SECTOR(S) EXT   READ VERIFY SECTOR(S)   READ VERIFY SECTOR(S) EXT   SECURITY DISABLE  PASSWORD   SECURITY ERASE PREPARE   SECURITY ERASE UNIT   SECURITY FREEZE LOCK   SECURITY SET PASSWORD   SECURITY UNLOCK   SEEK           B0h/D5h   B0h‐D1h  B0h/DAh   B0h/D3h   C4h   29h   F8h   27h   SMART READ LOG   SMART READ THRESHOLD  SMART RETURN STATUS   SMART SAVE ATTRIBUTE  VALUES   SMART WRITE LOG   STANDBY   STANDBY IMMEDIATE   WRITE BUFFER   20h   24h   40h   42h   F6h   WRITE DMA   WRITE DMA EXT   WRITE DMA FUA EXT  WRITE DMA (w/o retry)  WRITE FPDMA QUEUED   CAh   35h   3Dh  CBh  61h   F3h   F4h   F5h   F1h   F2h   70h‐7Fh        WRITE LOG EXT   WRITE LOG DMA EXT  WRITE MULTIPLE   WRITE MULTIPLE EXT   WRITE MULTIPLE FUA EXT  WRITE SECTOR(S)   WRITE SECTOR(S) EXT   WRITE SECTOR(S) (w/o retry)  WRITE UNCORRECTABLE EXT  3Fh   57h  C5h   39h   CEh  30h   34h   31h  45h  B0h/D6h   E2h  E0h  E8h   A.2. Identify Device Parameters  Word  0  1  2  3  4 – 5  6  7 – 8  9  10‐19  20  21  22  23 ‐ 26  27‐ 46  47  48  49  50  Contents  0C5Ah  3FFFh  C837h  0010h  0  003Fh  0  0000h  XXXX  0000h  4000h  3000h  XXXX  XXXX  8010h  0000h  2F00h  4000h  Description  General information  Number of logical cylinders  Specific configuration  Number of logical heads  Retired  Number of logical sectors per logical track  Reserved  Retired  Serial number(20 ASCII characters)  Retired  Buffer Memory Size  Obsolete  Firmware revision (8 ASCII characters)  Model number  Number of sectors on multiple commands  Reserved  Capabilities  Capabilities  21  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World 51 ‐ 52  53  54  55  56  57  58  59  60  61  62  63  64  65  66  67  68  69 ‐ 74  75  0200h  0007h  3FFFh  0010h  003Fh  FC10h  00FBh  0110h  XXXXh  XXXXh  0000h  0007h  0003h  0078h  0078h  0078h  0078h  0  001Fh    PIO Mode support  Reserved  Number of current logical cylinders  Number of current logical heads  Number of current logical sectors per track  Obsolete  Obsolete  Multiple sector setting  Total number of user addressable sectors (LBA mode only)  Total number of user addressable sectors (LBA mode only)  Obsolete  Multi‐word DMA transfer  Flow control PIO transfer modes supported  Minimum Multiword DMA transfer cycle time per word  Manufacturer’s recommended Multiword DMA transfer cycle time per word  Minimum PIO transfer cycle time without flow control  Minimum PIO transfer cycle time with IORDY flow control  Reserved  Queue Depth    Identify Device Parameters (continued)  Word  76  77  78  79  80  81  82  83  84  85  86  87  88  89  90  91  92  93  Contents  0706h  0000h  004Ch  0048h  00E0h  0000h  346Bh  7D21h  4022h  3469h  3C01h  4022h  407Fh  0000h  0000h  0000h  0000h  0000h  Description  Serial ATA capability   Reserved   Serial ATA features supported   Serial ATA features enabled   Major Version Number   Minor Version Number   Command sets supported   Command sets supported   Command set/feature supported extension   Command set/feature enabled   Command set/feature enabled   Command set/feature default   Ultra DMA transfer   Time required for security erase unit completion   Time required for Enhanced security erase completion   Current advanced power management value   Master Password Revision Code   COMRESET result   22  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World 94  95  96 ‐ 99  100 ‐ 103  104‐105  106  107  108 ‐ 111  112 ‐ 116  117 ‐ 118  119 ‐ 126  127  128  129 ‐ 159  160‐254  255    0000h  0000h  0  XXXX  0  0000h  0000h  XXXX  0  0  0  0000h  XXXXh  0  0  XXXXh    Automatic acoustic management value   Stream minimum request size   Reserved   Maximum user LBA for 48bit address feature set   Reserved   Physical sector size / logical sector size   Reserved   Unique ID   Reserved   Words per logical sector   Reserved   Removable media status notification feature set supported   Security status   Undefined   Reserved   Integrity word   23  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World   B. SMART  B.1. SMART Subcommand Sets  In order to select a subcommand the host must write the subcommand code to the device's  Features Register before issuing the SMART Function Set command. The subcommands are  listed below.  Command  SMART READ ATTRIBUTES  SMART READ THRESHOLD  SMART ENABLE/DISABLE ATTRIBUTE AUTOSAVE  SMART SAVE ATTRIBUTE VALUES   SMART EXECUTE OFF‐LINE IMMIDIATE   SMART READ LOG   SMART WRITE LOG   SMART WRITE ATTRIBUTE THRESHOLD  SMART ENABLE OPERATIONS   SMART DISABLE OPERATIONS   SMART RETURN STATUS     B.2. SMART Read Data (Subcommand D0h)  Command Code (Hex)  D0h  D1h  D2h  D3h  D4h  D5h  D6h  D7h  D8h  D9h  DAh  This subcommand returns the device's Attribute Values to the host. The Attribute Values consist  of 512bytes.  Device Attribute Data Structure  Byte  0:1  2:361  362  363  364:365  366  367  368‐369  370  371  372  373  374‐510  511  Description  Data structure revision number (Vendor Specific)   1st ‐ 30th Individual attribute data (Vendor Specific)   Off‐line data collection status   Self‐test execution status   Total time in seconds to complete off‐line data collection activity   Vendor Specific   Off‐line data collection capability   SMART capability   Error logging capability   7‐1 Reserved   0 1=Device error logging supported   Self‐test failure check point (Vendor Specific)   Short self‐test routine recommended polling time(in minutes)   Extended self‐test routine recommended polling time(in minutes)   Reserved   Data structure checksum   24  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World     Individual Attribute Data Structure  Byte  0  1:2  3  4  5:10  11  Description  Attribute ID Number   Status Flag   Nominal Value  Worst value since SSD was deployed  Raw data  Reserved     Attribute ID Numbers  ID  1  Attribute Name  Raw Read Error Rate   5  Retired Block Count  9  Power On Hours  (POH)  Device Power Cycle  Count  Program Fail Block  Count  Erase Fail Block Count  Unexpected Power  Loss Count  Wear Range Delta  12  171  172  174  177  181  Program Fail Count  182  Erase Fail Count  Description  Raw error rate related to ECC errors. Correctable and uncorrectable  RAISE errors are included in the error event count. (UECC + URAISE)   Tracks the total number of retired blocks. Data is calculated as 100‐ (100*RBC/MRB), where RBC is the retired block count and MRB is the  minimum required blocks. Also an indicator of remaining life.  Count of hours in power‐on state. The raw value of this attribute shows  total count of hours in power‐on state.   This attribute indicates the count of full hard disk power on/off cycles.  Counts the number of flash program failures.  Counts the number of flash erase failures.  Counts the number of unexpected power loss events since the drive was  deployed.  Returns the percent difference in wear between the most‐worn block  and least‐worn block  4 bytes used to show the number of program failures there have been.  (Identical to attribute 171.)  4 bytes used to show the number of block erase failures since the drive  was deployed. (Identical to attribute 172.)  25  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World     Attribute ID Numbers (continued)  ID  Attribute Name  187  Reported  Uncorrectable Errors  194  Temperature  195  On the fly ECC  Uncorrectable Error  Count  196  Reallocation Event  Count  231  SSD Life Left  233  Reserved  234  Reserved  241  Lifetime Writes from  Host  242  Lifetime Reads from  Host  Description  This attribute tracks the number of uncorrectable RAISE (URAISE) errors  reported back to the host for all data access commands.  Temperature assuming an on‐board sensor connected via ISTW interface  to the SF‐1500.  This attribute tracks the number of uncorrectable errors (UECC).  This attribute tracks the number of blocks that fail programming which  are reallocated as a result.   A measure of the estimated life left, based on a combination of PE cycles  and available reserve blocks. 100 is a new drive, 10=replace as it has  sufficient reserved blocks but the PE cycles have been used,  0=insufficient reserved blocks, drive is read only to allow recovery of  data on the drive.      Indicates the total amount of data written from hosts since the drive  was deployed. This is stored in 4 bytes. The number stored represents  the number of bytes written by the host to the drive, in 64GB  increments.  Indicates the total amount of data read to hosts since the drive was  deployed. This is stored in 4 bytes. The number stored represents the  number of bytes read by the host to the drive, in 64GB increments.    26  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.  UGB88PGCXXXXXX Solutions for a Real Time World   C. Contact Information  Corporate Headquarters  Unigen Corporation  45388 Warm Springs Blvd.  Fremont, CA 94539‐6102    (510) 688‐2088  (800) 826‐0808  (510) 661‐2770  [email protected]  www.unigen.com  (800) 826‐0808  Telephone:  Fax:  Email:  Web:  Customer Comment:    27  Re‐Tek‐1725  Released October 2010   http://www.unigen.com  COPYRIGHT UNIGEN CORPORATION, 2010  CONFIDENTIAL       Unigen Corporation reserves the right to change products or specifications without notice.  45388 Warm Springs Blvd.  Fremont, CA.  94539  Telephone: (510) 668‐2088  Fax: (510) 661‐2788  2010 Unigen Corporation. All rights reserved.