Preview only show first 10 pages with watermark. For full document please download

270/480 Dfo- Please Read This Manual Carefully Before Operation

   EMBED


Share

Transcript

Operation Manual Forced Convection Oven DFO-270/480 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 [email protected] MRC.4.15 -1- Contents 1.Specification ………………… ……… 2.Panel & KeyDescription ………………… ……… 3.Operations Description 3.1 Temperature Setting 3.2 Timer Setting 4.Error Codes & Corrective Action 5.Maintenance & Cleaning ………………… ……… ………………… ……… ………………… ……… 6.Warranty Card ………………… ……… 1.Specificatons -2- 3 4 5 8 9 10 Model DFO-270 DFO-480 DFO-600 DFO-720 DFO-1008 DFO-2160 Specs Convection Forced Convection Temp range Ambient +5℃ Temp accuracy ±1℃ Temp Control PID Temp Display Volume (liter) to 210℃ Digital 270 480 600 Shelf 720 1008 2160 8000 15,000 4(adjustable) Power Watts 3000 4000 6000 Keep Warm 6000 Mineral Wool Door 1 2 Timer 99.99 Interior Chamber is SUS304 Stainless Steel Exterior is Power Coating Material Power Voltage 110V/60Hz 220V/60 50 Hz 220V/ 60 50Hz Inner Dimension (mm) W D H 600 500 900 800 600 1000 1000 600 1000 1200 600 1000 1400 600 1200 1800 1000 1200 Overall Dimension (mm) W D H 780 620 1520 980 750 1600 1250 750 1580 1450 750 1580 1650 750 1820 2000 1200 1980 -3- Approx Weight 130kg 180 2.The Description Of the key on displays 1. MAIN : POWER (ON/OFF) 2. TEMP : Temperature display (refer the operation of 3.1) 3. TIMER: the switch of time setting (ON/OFF) The Max. time setting: 99 hours-59mini or 99 mini-59 sec. (refer the operation of 3.2) -4- 3.Operating 3.1Temperature Setting Code PV SV C1 C2 Description Display the set temperature Set the required temperature the 1st output pilot lamp the 2nd output pilot lamp A1 Alarm 1 lamp A2 Alarm 2 lamp MA Manual output pilot lamp Set and the codes recurred -5- Set for rise /return back the code Set for drop Set for move First press the key Second press the and make it flashed or for changing the setting After completing the setting, press the Press the key and key again together at any time, will return to the original display (or will answer automatically after 30 seconds. : The key for the codes recurred/ setting key A.Recurring key: will display the next code when press one time. B:The setting key : it needs to press one time the setting key for completing the setting when any code is be changed. : Rising key/ returning key A: Rising key: when the code is flashing, press the key, the value will be up. B: Returning key: When press the key, it will display the previous code. : Dropping key A: In flashing of the code, to press the key, the value will be dropped. : Moving key A: If want to change any code, it needs to press this key first and make it flashed for changing the value. -6- 3.2 Time Setting To turn on the timer for setting, it will turn off the heating function when it is the setting time. (at this time, the temperature will drop) -7- 4.Trouble Shooting SITUATION CAUSE TROUBLESHOOTI NG 1. LED is off when power on . a. NO power input Power plug is loose a. Check power supply system b. Abnormal voltage inputFuse b. Plug in firmly or blowout Power cord replace the socket disconnection or bad connection Check power supply and stop using temporarily Check power voltage and reset Replace switch place power cord -8- 2.After a. Chamber(bath)inside actual temperature temperature is higher than setting,Heating setting temperature PT platinum temperature LED=(OUT1) breakdown dropping or is off LED=(OUT1) Thermometer output signal…nil a. Waiting for cooling Replace Ask for repair 3.Heating LED a. Heater disconnection a. Ask for repair is on but b. Bad heater circuit b. Ask for repair temperature can c. Bad control circuit c. Ask for repair not d. Reset riseLED=(OUT1), d. High temperature protection-setting, locking e. Water supply e. Water level of floating ball is too low(water bath) 4.Temperature a. Temperature is out of control a. Ask for repair keep rising and b. Heater circuit is out of control b. Ask for repair out of control c. P.I.D.value is not correct P.I.D. c.Re-calculating d. S.S.R. breakdown automatically d. Ask for repair 5.temperature a. Temperature is unstable -9- a. Suspend for 30 tolerance is b. large P.T.D.value is not set or not correct . c. minute b. Re-calculating AT Temperature setting is too close to room temperature d. circulating fan or motor cannot work automatically c. Add cooling system or dropping ambient e. PT platinum bad connection PT temperature f. Air circulation inside is blocked d. Ask for repair e. Ask for repair f. Improve articles placement 5.Maintenance&Cleaning 1.Wipe machine with wet cloth first then wipe with try cloth again after using every time, please clean it with neutral lotion if there is any dirt. - 10 - 2. Please plug out for not using machine for a long time. 1. Please don’t put over weight article on the shelf to extend its service life.. 2. To keep door glass clean and bright please clean it with appropriate cleanser regularly. 6. WARRANTY CARD Product Name Forced Convection Oven Model Number Serial Number Date of purchase Warranty period - 11 - Company Stamp (Invalid without company stamp)  Condition of warranty 1. One-year warranty from the date of purchase for manufacturing defect. 2. In case damage is under normal condition of use within warranty, we will repair at no charge. 3. In case any manufacturing defect is found, it will be replaced with a new one free of charge. 4. Damage caused by card lost, human negligence, misuse or due to natural disaster, we will repair at a reasonable charge. - 12 -