PAGE 1
Installation, Operation, and Maintenance Manual
Ultra Violet Add-on Kit for Filtration Systems Model 550017 Important Please read the entire manual before proceeding with the installation and startup. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure. Save manual for future reference. DO NOT TOUCH THE UV LAMP OR QUARTZ TUBE AT ANY TIME WITH BARE HANDS OR FINGERS. Fingerprints or skin oils on the lamp and tube assembly may reduce UV functionality. This system requires a GFCI electrical outlet at point of installation.
Table of Contents Important. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Package Contents: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How To Use the Quick Connect Fittings. . . . . . . . . . . . . . . . . . . . . . . Installation: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Please follow these guidelines:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ultra Violet Bulb Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 2 2 2 2 4
8716 West Ludlow Dr, Ste 1, Peoria, AZ 85381 Tel. (800) 752-5582 • Fax: (623) 866-5666 • www.premierh2o.com
Manual #299340
Rev 10/18/12
© 2012 Premier
PAGE 2
Package Contents:
Installation:
Examine the components carefully to make sure no damage has occurred. Care should be taken to ensure the parts are not dropped or mishandled; dropping will damage the components
The following steps describe installing the UV Kit onto a Reverse Osmosis System. For other systems please contact customer support at 1-800-752-5582. Step 1 - Turn off the incoming water to the reverse osmosis unit Step 2 - Lift the handle on the reverse osmosis faucet to drain the water from the system and storage tank. Note: If the tank is equipped with a ball valve, close valve to preserve tank water. Step 3 - Remove the protective plugs from the UV Module Ports making sure not to damage the quick-connect fittings
3 UV MODULE
1
Step 4 - If you have a Standard-Style System, you can mount the UV Module onto the Membrane Housing using the provided clips Step 5 - Locate the tube that connects the tank to the filters then cut the tube in the middle.
1
Step 6 - Connect the UV Module to the cut ends of the tube (direction of the UV Module is not important) 2
NOTE: If the tube connecting the tank to the filters is 3/8" diameter, use the supplied adapters and 1/4" tubes as shown in Figure 3
2
4 TRANSFORMER
Step 7 - Turn on the water supply and check for leaks. If you have any leaks, shut off water supply to system, repair and restart unit Step 8 - Connect plastic electrical connector from UV unit to the plastic electrical connector from AC adapter
Ultra Violet Add-on Kit Parts List ITEM #
PART#
1 2 3 4 -
164010 125037 170031 270093 270110 710450
DESCRIPTION
MOUNTING CLIP UNION ADAPTER - 1/4" QC X 3/8" QC UV MODULE TRANSFORMER REPLACEMENT BULB (NOT SHOWN) 3" LONG 1/4" BLUE TUBE (NOT SHOWN)
How To Use the Quick Connect Fittings To make a connection, the tube is simply pushed in by hand; the unique patented John Guest collet locking system then holds the tube firmly in place without deforming it or restricting flow.
Step 9 - Plug adapter into GFCI electrical outlet. You will see a pale blue light from the view port at the end of the UV housing body. The light indicates that the UV lamp is on and working
Please follow these guidelines: Do not unplug UV unit from power supply. Turning system off and on will shorten the life of the UV lamp. UV should be on continuously for maximum effectiveness. The system requires a warm-up period for proper operation. Wait 20 minutes after plugging in the system before using water. Water not drawn from unit for a period of time may have a taste or odor and will be warm. To avoid this, allow water to run through the system for one minute before using.
Cut the tube square and remove burrs and sharp edges. Ensure that the outside diameter is free from score marks.
Push the tube into the fitting and up to the tube stop
Pull on the tube to check that it is secure. Test the system before use
To disconnect, ensure that the system is depressurized, push the collet square against the fitting. With the collet held in this position the tube can be removed. 8716 West Ludlow Dr, Ste 1, Peoria, AZ 85381 Tel. (800) 752-5582 • Fax: (623) 866-5666 • www.premierh2o.com
Manual #299340
Rev 10/18/12
© 2012 Premier
PAGE 3
FAUCET
DRAIN SADDLE
3/8” BLACK TUBE DRAIN
3/8” BLUE TUBE
1/4” BLUE TUBE - PERMEATE
1/4” RED TUBE - BRINE
TANK SHUT-OFF VALVE
SHUT-OFF VALVE
1/4” BLUE TUBE
1/4” BLUE TUBE
TO KITCHEN SINK
UV MODULE
ADAPT-A-VALVE
MAIN WATER SUPPLY SHUT-OFF VALVE
STORAGE TANK
Figure 1: RO Pure + UV Module
INLINE POST-FILTER
1/4” BLUE TUBE
1/4” BLUE TUBE
SHUT-OFF VALVE
MEMBRANE UV MODULE
STORAGE TANK
TO KITCHEN SINK
ADAPT-A-VALVE
COLD-WATER SHUT-OFF VALVE SEDIMENT
CARBON
CARBON
Figure 2: Standard System System + UV Module
8716 West Ludlow Dr, Ste 1, Peoria, AZ 85381 Tel. (800) 752-5582 • Fax: (623) 866-5666 • www.premierh2o.com
Manual #299340
Rev 10/18/12
© 2012 Premier
PAGE 4
DRAIN LINE
BRINE LINE Faucet Tap
Tank
Drain
FAUCET LINE INLINE POST-FILTER (WP-5 ONLY)
3/8” TANK LINE
1/4” TUBING
1/4” TUBING
TO KITCHEN SINK MANIFOLD FEED WATER
UV MODULE
ADAPT-A-VALVE
COLD-WATER SHUT-OFF VALVE
STORAGE TANK
Figure 3: Manifold Style Unit + UV Module
Ultra Violet Bulb Replacement Watts recommends changing the UV-Lamp Every 12 months or 9000 hours Step 1 - Turn off the incoming water supply. Step 2 - Lift the handle on the reverse osmosis faucet to drain the water from the system and storage tank. Note: If the tank is equipped with a ball valve, close valve to preserve tank water. Step 3 - Unplug transformer from the power outlet and disconnect transformer wire harness from the UV lamp at the plastic connector.
UV BULB
Step 4 - Remove UV lamp from housing by pulling on the UV wire harness away from the UV housing. Use caution when removing lamp not to break glass. Discard of old lamp. Warning: Do not touch UV Lamp or Quartz Tube with bare fingers or hands. Fingerprints on the lamp or tube may reduce lamp effectiveness. Handle with clean cloth or gloves.
UV MODULE
Step 5 - Install new lamp by pushing it into the UV housing using the white end cap. Step 6 - Plug the transformer power cord connector into the UV module wire harness connector and plug the transformer into an electrical outlet. The white UV end cap will light up when in service (Plugged in).
Figure 4: UV Tube Assembly
Step 7 - Turn on the incoming water supply and check for leaks Step 8 - Snap UV housing body back into mounting clip. Reconnect the 1⁄4" blue tubing back on to the UV housing body