Transcript
RAID Vault 2 2 Bay 2.5”/3.5” HDD RAID Enclosure
SUPERSPEED
USB 3.0
www.dyconn.com
Product OVErVIEW Product Description: The Dyconn RAID Vault 2 2.5”/ 3.5” HDD 2-bay RAID Enclosure is the perfect data management companion with its ability to read 2 HDDs at the same time. The Dyconn RAID Vault 2 provides superior heat dissipation due to its innovative contemporary design and interior cooling system. The unique tray design provides both easy HDD accessibility and limits vibration and shock to the drives while in use. It impressively supports RAID (Normal, RAID 0, RAID 1, COMBINE/BIG ) and provides the fast data transfer rate of USB 3.0 (up to 5Gbps). In addition, the Dyconn RAID Vault 2 has an intelligent sleep function, which is an economical and efficient data storage tool.
Product Features: • • • • • • • • • •
Support 2 Bay 2.5”/3.5” Sata HDDs SECC metal construction Vibration/Shock Proof Tray Design Capable of simultaneously reading 2 HDDs Supports HDD Mirror Functionality HDD with Intelligent Sleep Mode USB 3.0 interface supports 5Gbps RAID Support: Normal, RAID 0, RAID 1, BIG 1 (60mm) Silent Cooling Fan (for temperature control and heat dissipation) Supports USB 3.0, USB 2.0/1.1 (USB 3.0 is AKA USB 3.1(Genl)
Package Contents: • Dyconn RAID Vault 2 • USB 3.0 Cable • 110/220 AC to 12V DC Power adapter • Instruction Guide
Specifications: Support HDD: Compatible OS:
2.5”/ 3.5” Sata HDD Windows Vista 7, Windows 8, 10, Mac OS 10.4 or above Approval Safety: CE and FCC Approval Material: SECC metal construction Dimensions: 5.19” W x 4.5” H x 8.75” D (132 W x 114 H x 222 D mm) Weight: 3.8 lbs (1.7kg) Operation Temp.: 5˚C / 40˚C Storage Temp.: -20˚C / 70˚C
2
Product Diagram
1) To remove the HDD tray: press and hold the tray blue part with your thumb and index finger to pull the tray outward, install the HDD onto the tray, then place the tray back to the enclosure, please put the bottom of the tray parallel on HDD tray, so that it can be pushed and slide in to place. 2)HDD status LED :Blue Light - the hard disk working properly , Blinking RED light indicate RAID error or HDD error: Blinking RED light - the hard disk to read and write, or Blinking RED when RAID rebuild 3) Power Switch: to turn ON or OFF the device power. 4) RAID0/JBOD/RAID1 LED: indicate RAID mode, It’s Normal mode when the three led lights aren’t light 5) Reset: Press Reset button when changing the RAID mode setting 6) RAID: RAID mode jumper switch, please see Section # 4-2 below for more details 6) USB3.0 Port: to be connected to an USB3.0 port of a PC with the enclosed USB3.0 cable. 7) Power input: DC12V power input socket 8)FAN:Smart Fan, When one of the hard disk temperature reached 40℃ then the Fan run, If all off the hard disk temperature is lower than 38℃, the Fan will stop automatically.
3
INSTALLATION of hard drive Step 1: Install the 3.5” Hard disks Please remove the plug of power supply from the outlet before installing the hard disk, to avoid any electric shock or damage. 1. To remove the HDD tray: press and hold the tray blue part with your Thumb and index finger to pull the tray outward. 2. Place the HDD on the tray, remove the 2 side snaps (blue color plastic), then place the HDD onto the tray with the HDD screw holes onto the pillars on the bottom of the tray. 3. Lock the HDD on the tray by replacing the side snaps back to each side of tray. 4. Place the installed trays back to the enclosure, connect the power cord back, connect the USB 3.0 cable with the USB port of your computer, then turn ON the enclosure. The RAID VAULT 2 is ready for use..
Step 1: Install the 2.5” Hard disks 1. Remove the side snap on each side of tray 2. Fix the 2.5” HDD on the tray with 4 screws (enclosed in the package)
4
INSTALLATION of hard drive The setting of RAID mode Hard disk combined mode can be set by setting the MODE jumper switches on the rear panel of the enclosure. RAID SWICH SETTING LIST
Item S/W 1 S/W 2 RAID MODE Description 1
OFF
OFF
3
ON
OFF
2
4
OFF ON
Normal
Normal , works as 2 individual HDD’s
RAID0
RAID0, works as 1 single HDD
ON
JBOD
ON
RAID1
JBOD, works a 1 single HDD
RAID1, works as 1 single HDD
RAID mode change procedure Before using this product, please back up your original data in the hard drives, as the data in the hard drives might be lost during the RAID mode setting. Please refer to the above RAID SWITCH SWETTING LIST to do the mode setting; and follow the below procedures to set the jumper switches: Setting new mode, pls. follow the mode list as below, press the Rest button for 8sec after turn on the power,
WARNINGS:
Please backup the data in your hard disk before setting any RAID at the beginning, as the RAID mode setting procedure will initialize the hard drive(s) into the virtual disk volumes and completely remove the original data from the hard drive(s) first. 5
The Disk Configuration at each Switch Setting
Initialization in Mac OS X Run 【Disk Utility】to initialize and format hard disk ※ Note:if you have to use the WINDOWS OS, do not format hard disk in MAC OS, please use FAT32 format hard disk. 6
Initialization and format the hard disk Initialization in Windows7/windows vista/Windows 2000 / XP/ Vista CAUTION! Partitioning and formatting a disk drive will delete the original data in the HDD. We assume NO responsibility for your lost data.
To format the new RAID VAULT 2 HDD, follow the below command path: “start” menu” ---“control Panel”---“Management tools”---“computer management” ---“storage” ---“Disk management” to format the new RAID VAULT 2 disk step by step. Or go to the desktop “my computer”, connect the new RAID VAULT 2 to the computer, a new hard disk code will appear, move the cursor to the new hard disk code and select to format the new hard drive(s). You may select “quick format” in order to save the time to format hard disk
7
TROUBLESHOOTING Connecting to PC
After boot your computer, follow below steps to connect RAID VAULT 2 with your computer: 1. Start your computer and wait until the computer is booted 2. Use the enclosed power adapter to connect RAID VAULT 2 to the power outlet, connect USB cable, and turn RAID VAULT 2 ON. 3. The HDD1~HDD2 hard disk power LED lamps will be ON indicating the status of the installed hard disk(s).
Disconnecting RAID VAULT 2 from the PC
Before disconnecting RAID VAULT 2 from the PC, please follow the below steps to disconnect the USB cable at RAID VAULT 2
Troubleshooting 1. The RAID VAULT 2 device is not recognized when connect to a computer. Or the device does not work well. • Check the status and connection of the power switch and supply outlet. • Check whether the connection of the USB 3.0 cable is firmly connected. • Check the jumper of each hard disk which is set correctly. • Check if each HDD is well installed in the enclosure. • Please check the OS limitation of filing system and partition capacity vs. what you are using. • Windows 2000/XP can not perform “disk management” program You must be logged on as an administrator in order to initialize hard disk at the system of WINDOWS 2000/XP 2. USB transfer speed is slow. • If your computer might not be with an USB3.0 interface, you may add a PCI to USB3.0 card into your computer.If your computer interface is USB2.0, then the product transfer speed is USB2.0 speed. • If RAID VAULT 2 is connected to the computer via a USB HUB, please verify whether the USB hub is USB3.0 version, if it is USB2.0, the then the transfer speed can only be at USB2.0 speed. • Your computer is connected with more than 1 USB device may slower down the USB transfer speed,. please remove the other USB devices that are not in use. • Make sure use the attached USB 3.0 CABLE. 8
3. In Windows 98 SE and Mac OS cannot recognize HDD which already formatted in Windows 2000 / XP. Please refer to the following to confirm if you are using a supported file format OS
Filing System NTFS
FAT32
HFS
Windows 98 SE
X
O
X
Windows ME
X
O
X
Windows 2000 Pro
O
Windows XP
O
Mac OS
X
O∆
O∆ O‡
X X O
∆
WINDOWS system can only format FAT32 file system to 32GB, if you need to format the hard disk over 32GB,please use other vendor programs, such as “Norton Partition Magic”. ‡ MAC OS can not format FAT32 file format, please format hard drive in the WINDOWS OS
3. The description of hard disk capacity calculated As the hard disk supplier’s operation system is different, it will have a different method of calculation capacity. So showed capacity is less than the hard drive marked capacity. This calculates capacity indication of a hard disk at 1GB =1000MB, but a calculation on the OS is calculated at 1GB =1024MB. For example: Three 400GB combined into one hard disk, the disk space is 1.2TB, after the operation system formatting, the differences as below: HardDisk OS
1.2TB 1.09TB
1,200GB 1,117GB
9
1,200,000MB 1,144,409MB
dyconn limited warranty DYCONN warrants only to the original purchaser of this product from a Dyconn authorized reseller or distributor that this product will be free from defects in material and workmanship under normal use and service for (1) one-year after date of purchase. Purchaser must present acceptable proof of original ownership (such as original receipt, warranty card registration, on-line registration, or other documentation Dyconn deems acceptable) for the product. DYCONN, at its option, shall repair or replace the defective unit covered by this warranty. In order to keep this limited warranty in effect, the product must have been handled and used as prescribed in the instructions accompanying this warranty. This limited warranty does not cover any damage due to accident, misuse, abuse or negligence. This limited warranty is non-transferable and does not apply to any purchaser who bought the product from a reseller or distributor not authorized by Dyconn, including but not limited to purchases from internet auction sites. This warranty does not affect any other legal rights you may have by operation of law. Contact DYCONN at 1-(855) 839-2666 for warranty service procedures. DISCLAIMER OF WARRANTY EXCEPT FOR THE LIMITED WARRANTY PROVIDED HEREIN, TO THE EXTENT PERMITTED BY LAW, DYCONN DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ALL WARRANTIES OF MERCHANTIABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. TO THE EXTENT THAT ANY IMPLIED WARRANTIES MAY NONETHELESS EXIST BY OPERATION OF LAW, ANY SUCH WARRANTIES ARE LIMITED TO THE DURATION OF THIS WARRANTY. SOME STATES/PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LON GAN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. LIMITATION OF LIABILITY REPAIR OR REPLACEMENT OF THIS PRODUCT, AS PROVIDED HEREIN, IS YOUR EXCLUSIVE REMEDY. DYCONN SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOST REVENUES, LOST PROFITS, LOSS OF USE OF ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOST REVENUES, LOST PROFITS, LOSS OF USE OF SOFTWARE LOSS OR RECOVERY OF DATA, RENTAL OF REPLACEMENT EQUIPMENT, DOWNTIME, DAMAGE TO PROPERTY, AND THIRD-PARTY CLAIMS, ARISING OUT OF ANY THEORY OF RECOVERY, INCLUDING WARRANTY, CONTRACT, STATUTORY OR TORT. NOTWITHSTANDING THE TERM OF ANY LIMITED WARRANTY OR ANY WARRANTY IMPLIED BY LAW, OR IN THE EVENT THAT ANY LIMITED WARRANTY FAILS OF ITS ESSENTIAL PURPOSE, IN NO EVENT WILL DYCONN’S ENTIRE LIABILITY EXCEED THE PURCHASE PRICE OF THIS PRODUCT. SOME STATES/PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE AND PROVINCE TO PROVINCE.
Technical Support For technical support, call 1-(855) 839-2666. . You may also reach Dyconn technical support at
[email protected]
10