Preview only show first 10 pages with watermark. For full document please download

2u-m1000 ~ 3u-m5000 Ups (smart Guard Series)

   EMBED


Share

Transcript

SMART GUARD LINE INTERACTIVE SINEWAVE UPS Designed with simple controls for easy operation, the Smart Guard UPS provides true sine-wave power regardless of the input power profile, making it ideal for electronic equipment that is sensitive to any power fluctuations. The Smart Guard family offers power protection in 1KVA-5KVA is excellent power protection for your Networks and Servers. Functions & Fetures: ‧Rack & Tower Transmutable ‧Line interactive design ‧Boost and buck AVR ‧Intelligent fan speed control ‧Pure sine wave output ‧Fully digitized microprocessor controlled ‧Smart RS-232 communication port ‧Lightning and surge protection ‧Normal、back up、fault status LED or LCD display ‧Short circuit and overload protection ‧50/60Hz frequency auto sensing ‧Tel/modem internet spike protection ‧Smart power management with software ‧Load/Battery power meter display ‧Energy saving (UPS sleep mode) ‧Cold start (DC power on) ‧SNMP capability (optional) ‧USB capability (optional) 3U Type 2U Type Feature: Compete with APC Smart Guard RT series Model Standard Mode 2U-M1000 2U-M1500 2U-M2000 3U-M3000 3U-M5000 Capacity VA / Watt 1KVA / 600W 1.5KVA / 900W 2KVA / 1200W 3KVA / 1800W 5KVA / 3000W Nominal Voltage 110Vac / 220Vac Acceptable Voltage Range Frequency 85Vac ~ 150Vac / 170Vac ~ 300Vac 50Hz ±10%/ 60Hz ±10% Auto Sensing 100Vac ± 2% / 200Vac ± 2% Boost Transfer Input Voltage Range Boost Return 105Vac ± 2% / 210Vac ± 2% Buck Transfer 120Vac ± 2% / 240Vac ± 2% Buck Return 115Vac ± 2% / 230.0Vac ± 2% Line Low Transfer 85Vac ± 2% / 170Vac ± 2% Line Low Return 90Vac ± 2% / 180Vac ± 2% Line High Transfer 145Vac ± 2% / 290Vac ± 2% 140Vac ± 2% / 280Vac ± 2% Line High Return Voltage Voltage Regulation Frequency Regulation Output 110Vac / 220Vac ----- LCD panel ± 15% Line Mode ± 5% RMS for entire battery voltage range Battery Mode Follow Ac Line Hz Line Mode 50Hz or 60Hz ±0.1Hz Battery Mode Pure Sine wave Waveform 0.6 Power Factor > 80% Effiecincy Overload Protection Transfer Time Battery Circuit Breaker Line Mode 110% ~ 150% for 30 sec. , >150% for 200ms Battery Mode 2-4 ms. Typical Battery Voltage 24Vdc 36Vdc 36Vdc 36Vdc Battery Type 7.2AH 7.2AH 9AH 7.2AH 9AH 2pcs 3pcs 3pcs 6pcs 8pcs Battery Quantity Backup Time Standard Mode 5-10 min ( at full load ) Recharge Standard Mode 4 hours ( to 90% of full capacity ) 48Vdc LCD UPS status, I/P&O/P Voltage Frequency, Load%,Battery Voltage & %, Temperature, Model LED Normal (Green), Back up (Yellow), Fault (Red) Display Audible Alarm Battery Mode Beeping every 4 seconds Low Battery Beeping every 1 second UPS Fault Beeping Continuously Overload Beeping twice per second Communication Port RS232 Operation Temperature Environment 0-40 degree C; 32-104 degree F Relative Humidity 0-95% non-dondensing Audible Noise Less than 45dBA (at 1M) Net Weigh (Kgs) Physical Standard Mode 16Kgs 17.5Kgs 24.5Kgs 37Kgs 50Kgs 405*440*88 405*440*88 620*440*132 465*440*132 ( 110V / 220V) (DxWxH)mm 405*440*88 Software * Specifications are subjected to change without prior notice. Support Windows 95/98/NT/2000/XP, Novell , and Linux