Preview only show first 10 pages with watermark. For full document please download

2u Sas Jbod Enclosure Configuration Guide

   EMBED


Share

Transcript

2U SAS JBOD Enclosure Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your storage system. July 24, 2015 Revision 4.0 NEC Corporation CONFIGURATION GUIDE – 2U SAS JBOD Enclosure Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 4 Front and Rear Views ........................................................................................................................... 4 Dimensions (mm) .................................................................................................................................. 8 2U 2.5-inch SAS JBOD Enclosure N8192-101F ............................................................................. 8 2U 3.5-inch SAS JBOD Enclosure N8192-102F ............................................................................. 9 2U 2.5-inch SAS JBOD Enclosure N8192-103F ........................................................................... 10 2U 3.5-inch SAS JBOD Enclosure N8192-104F ........................................................................... 11 UNIT CONFIGURATION ................................................................................................ 12 1 External Drive Configuration ...................................................................................................... 12 1.1 2U 2.5-inch SAS JBOD Enclosure (1) ................................................................................. 12 1.2 2U 2.5-inch SAS JBOD Enclosure (2) ................................................................................. 13 1.3 2U 2.5-inch SAS JBOD Enclosure (3) ................................................................................. 14 1.4 2U 3.5-inch SAS JBOD Enclosure (1) ................................................................................. 15 1.5 2U 3.5-inch SAS JBOD Enclosure (2) ................................................................................. 16 1.6 2U 3.5-inch SAS JBOD Enclosure (3) ................................................................................. 17 COPYRIGHT NOTICE AND LIABILITY DISCLAIMER ................................................. 18 REVISION HISTORY ..................................................................................................... 19 NEC Corporation Revision 4.0 – July 24, 2015 2 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure Technical Specification Key Features    Compact direct attached storage Twenty four 2.5-inch or twelve 3.5-inch drive bays in 2U enclosure Superior reliability with hot plug redundant power supplies and redundant fans Specification (1/2) Model 2U SAS JBOD Enclosure Part Number Storage N8192-101F N8192-102F Maximum Capacity 28.8 TB SAS 48 TB NL SAS Hot Plug Supported Drive Bays 24 12 Interfaces One SFF-8088 mini-SAS Connector Redundant Power Supply Standard, hot plug Power Supply Two hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Maximum Power Consumption 300 Watt Dimensions (W x D x H ) 482.0 x 552.9 x 87.8 mm / 19.0 x 21.8 x 3.5 in (2U) Weight (Maximum) 29 kg, 63.93 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 35° C / 50° to 95° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% 310 Watt (2/2) Model 2U SAS JBOD Enclosure Part Number Storage N8192-103F N8192-104F Maximum Capacity 43.2 TB SAS 72 TB NL SAS Hot Plug Supported Drive Bays 24 12 Interfaces One mini-SAS HD Connector Redundant Power Supply Standard, hot plug Power Supply Two hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Maximum Power Consumption 330 Watt Dimensions (W x D x H ) 482.6 x 548.5 x 87.4 mm / 19.0 x 21.6 x 3.4 in (2U) Weight (Maximum) 28 kg, 61.73 lbs. Temperature, Relative Humidity (non-condensing) Operating: 5° to 40° C / 41° to 104° F, 10 to 80% Non-Operating: -10° to 60° C / 14° to 140° F, 5 to 80% NEC Corporation Revision 4.0 – July 24, 2015 270 Watt 3 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure External Views Front and Rear Views Front View for N8192-101F and N8192-102F 2U 2.5-inch SAS JBOD Enclosure (N8192-101F) E F A B C D G 2U 3.5-inch SAS JBOD Enclosure (N8192-102F) E F A B C D G Legend A. ID LED E. Hard Drive Activity LED B. Service LED F. Hard Drive Fault LED C. Power LED G. Drive Bays D. Standby LED NEC Corporation Revision 4.0 – July 24, 2015 4 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure Rear View for N8192-101F and N8192-102F A B C D E F G H I J K L M Legend A. Power Switch H. Controller Ready LED B. AC Inlet I. Controller Fault LED C. AC Power Good LED J. ID LED D. Power Fault LED K. SAS Link LED E. Service Action LED L. SAS Fault LED F. DC Power Good LED M. SFF-8088 mini-SAS Connector G. Standby Power Good LED NEC Corporation Revision 4.0 – July 24, 2015 5 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure Front View for N8192-103F and N8192-104F 2U 2.5-inch SAS JBOD Enclosure (N8192-103F) E D A B C 2U 3.5-inch SAS JBOD Enclosure (N8192-104F) D E A B C Legend A. ID LED(Not used) D Hard Drive Activity LED B. Service LED E Hard Drive Fault LED C. Power LED NEC Corporation Revision 4.0 – July 24, 2015 6 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure Rear View for N8192-103F and N8192-104F I J K A B M L C D E F G H N Legend A. Power Switch B. H. Debug port(Not used) mini-SAS HD Connector(Not used) I. RDY LED C. mini-SAS HD Connector(Not used) J. AC IN LED D. mini-SAS HD Connector K. ALM LED E. Controller Ready LED L. AC Inlet F. Controller Fault LED M. SAS Link LED ID LED(Not used) N SAS Fault LED G. NEC Corporation Revision 4.0 – July 24, 2015 7 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure Dimensions (mm) 2U 2.5-inch SAS JBOD Enclosure N8192-101F NEC Corporation Revision 4.0 – July 24, 2015 8 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure 2U 3.5-inch SAS JBOD Enclosure N8192-102F NEC Corporation Revision 4.0 – July 24, 2015 9 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure 2U 2.5-inch SAS JBOD Enclosure N8192-103F NEC Corporation Revision 4.0 – July 24, 2015 10 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure 2U 3.5-inch SAS JBOD Enclosure N8192-104F NEC Corporation Revision 4.0 – July 24, 2015 11 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure Unit Configuration 1 External Drive Configuration 1.1 2U 2.5-inch SAS JBOD Enclosure (1) Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID0/1/5/6) LSI MegaRAID SAS 9285-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 6Gb/s RAID Controller (1GB, RAID0/1/5/6) LSI MegaRAID SAS 9286CV-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 3.0 x8, SAS 6Gb/s, SATA 6Gb/s, flash cache protection modules included RAID Battery Backup Unit for LSI MegaRAID SAS 9285-8e External SATA Cable 2 m, 1 x SFF-8088 to 1 x SFF-8088 2U 2.5-inch SAS JBOD Enclosure 24 x 2.5-inch Hot-plug hard drive bays Front Bezel For N8192-101F/102F 300GB HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm 450GB HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm 600GB HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB HDD 1 x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB HDD 1 x 1.2 TB, SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm N8103-160 RAID BBU Recommended Cable 1 to 2 Required Enclosure 1 to 2 Required Bezel Drive 24 slots available N8103-161 N8103-162 K410-191(02) N8192-101F N8192-302F N8192-501 N8192-502 N8192-503 N8192-504 N8192-508 NOTE:         Storage controllers must be compatible with the server connected. The drive enclosures connected to one storage controller must be identical. One drive enclosure can be connected to one port of storage controller. Eight and more disk drives must be installed. All hard drives within a RAID array should be of the same capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. Any of RAID arrays cannot be used as a boot device. NEC Corporation Revision 4.0 – July 24, 2015 12 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure 1.2 2U 2.5-inch SAS JBOD Enclosure (2) Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID0/1/5/6) LSI MegaRAID SAS 9380-8e RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s, Flash cache protection modules included External SATA Cable 2 m, 1 x SFF-8088 to 1 x SFF-8644 2U 2.5-inch SAS JBOD Enclosure 24 x 2.5-inch Hot-plug hard drive bays Front Bezel For N8192-101F/102F 300GB HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm 450GB HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm 600GB HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB HDD 1 x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB HDD 1 x 1.2 TB, SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm N8103-179 Cable 1 to 2 Required Enclosure 1 to 2 Required Bezel Drive 24 slots available K410-322(02) N8192-101F N8192-302F N8192-501 N8192-502 N8192-503 N8192-504 N8192-508 NOTE:         Storage controllers must be compatible with the server connected. The drive enclosures connected to one storage controller must be identical. One drive enclosure can be connected to one port of storage controller. Eight and more disk drives must be installed. All hard drives within a RAID array should be of the same capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. Any of RAID arrays cannot be used as a boot device. NEC Corporation Revision 4.0 – July 24, 2015 13 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure 1.3 2U 2.5-inch SAS JBOD Enclosure (3) Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID0/1/5/6) LSI MegaRAID SAS 9380-8e RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s, Flash cache protection modules included External SATA Cable 2 m, SFF-8644 to SFF-8644 2U 2.5-inch SAS JBOD Enclosure 24 x 2.5-inch Hot-plug hard drive bays Front Bezel For N8192-103F/104F 600GB 10K Hot Plug 2.5-inch SAS HDD For N8192-103F, 2.5-inch SAS 10K HDD, 12Gb/s, 512B sector 1.2TB 10K Hot Plug 2.5-inch SAS HDD For N8192-103F, 2.5-inch SAS 10K HDD, 12Gb/s, 512B sector 1.8TB 10K Hot Plug 2.5-inch SAS HDD For N8192-103F, 2.5-inch SAS 10K HDD, 12Gb/s, 4KB sector N8103-179 Cable 1 to 2 Required Enclosure 1 to 2 Required Bezel Drive 24 slots available SAS HDD (512B) SAS HDD (4KB) K410-333(02) N8192-103F N8192-303F N8192-514 N8192-516 N8192-513 NOTE:          Storage controllers must be compatible with the server connected. One drive enclosure can be connected to one port of storage controller. The drive enclosures connected to one storage controller must be identical. At least eight drives must be installed. All hard drives within a RAID array should be of the same capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. Any of RAID arrays cannot be used as a boot device. When you select 4KB sector HDD, confirm whether your applications support hard drives with 4 KB sector size. For more information, visit the NEC website at: http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf  The 4KB sector drives are make-to-order products. Please consult your sales representative in regard to production lead time. NEC Corporation Revision 4.0 – July 24, 2015 14 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure 1.4 2U 3.5-inch SAS JBOD Enclosure (1) Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID0/1/5/6) LSI MegaRAID SAS 9285-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 6Gb/s RAID Controller (1GB, RAID0/1/5/6) LSI MegaRAID SAS 9286CV-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 3.0 x8, SAS 6Gb/s, SATA 6Gb/s, flash cache protection modules included RAID Battery Backup Unit for N8103-160 LSI MegaRAID SAS 9285-8e N8103-160 External SATA Cable 2 m, 1 x SFF-8088 to 1 x SFF-8088 2U 3.5-inch SAS JBOD Enclosure 12 x 3.5-inch Hot-plug hard drive bays Front Bezel For N8192-101F/102F 1TB 7.2K Hot Plug 3.5-inch NL SAS HDD 1 x 1 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch NL SAS HDD 1 x 2 TB NL SAS HDD,32.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch NL SAS HDD 1 x 3 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch NL SAS HDD 1 x 4 TB, NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm K410-191(02) RAID BBU Recommended for N8103-160 Cable 1 to 2 Required Enclosure 1 to 2 Required Bezel Drive 12 slots available N8103-161 N8103-162 N8192-102F N8192-302F N8192-505 N8192-506 N8192-507 N8192-509 NOTE:         Storage controllers must be compatible with the server connected. The drive enclosures connected to one storage controller must be identical. One drive enclosure can be connected to one port of storage controller. Four or more disk drives must be installed. All hard drives within a RAID array should be of the same capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. Any of RAID arrays cannot be used as a boot device. NEC Corporation Revision 4.0 – July 24, 2015 15 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure 1.5 2U 3.5-inch SAS JBOD Enclosure (2) Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID0/1/5/6) LSI MegaRAID SAS 9380-8e RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s, Flash cache protection modules included External SATA Cable 2 m, 1 x SFF-8088 to 1 x SFF-8644 2U 3.5-inch SAS JBOD Enclosure 12 x 3.5-inch Hot-plug hard drive bays Front Bezel For N8192-101F/102F 1TB 7.2K Hot Plug 3.5-inch NL SAS HDD 1 x 1 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch NL SAS HDD 1 x 2 TB NL SAS HDD,32.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch NL SAS HDD 1 x 3 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch NL SAS HDD 1 x 4 TB, NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-179 Cable 1 to 2 Required Enclosure 1 to 2 Required Bezel Drive 12 slots available K410-322(02) N8192-102F N8192-302F N8192-505 N8192-506 N8192-507 N8192-509 NOTE:         Storage controllers must be compatible with the server connected. The drive enclosures connected to one storage controller must be identical. One drive enclosure can be connected to one port of storage controller. Four or more disk drives must be installed. All hard drives within a RAID array should be of the same capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. Any of RAID arrays cannot be used as a boot device. NEC Corporation Revision 4.0 – July 24, 2015 16 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure 1.6 2U 3.5-inch SAS JBOD Enclosure (3) Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID0/1/5/6) LSI MegaRAID SAS 9380-8e RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s, Flash cache protection modules included External SATA Cable 2 m, SFF-8644 to SFF-8644 2U 3.5-inch SAS JBOD Enclosure 12 x 3.5-inch Hot-plug hard drive bays Front Bezel For N8192-103F/104F 2TB 7.2K Hot Plug 3.5-inch NL SAS HDD For N8192-104F, 3.5-inch NL-SAS 7.2K HDD, 6Gb/s, 512B sector 4TB 7.2K Hot Plug 3.5-inch NL SAS HDD For N8192-104F, 3.5-inch NL-SAS 7.2K HDD, 6Gb/s, 512B sector 6TB 7.2K Hot Plug 3.5-inch NL SAS HDD For N8192-104F, 3.5-inch NL-SAS 7.2K HDD, 6Gb/s, 4KB sector N8103-179 Cable 1 to 2 Required Enclosure 1 to 2 Required Bezel Drive 12 slots available SAS HDD (512B) SAS HDD (4KB) K410-333(02) N8192-104F N8192-303F N8192-520 N8192-522 N8192-519 NOTE:          Storage controllers must be compatible with the server connected. The drive enclosures connected to one storage controller must be identical. One drive enclosure can be connected to one port of storage controller. At least four drives must be installed. All hard drives within a RAID array should be of the same capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. Any of RAID arrays cannot be used as a boot device. When you select 4KB sector HDD, confirm whether your applications support hard drives with 4 KB sector size. For more information, visit the NEC website at: http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf  The 4KB sector drives are make-to-order products. Please consult your sales representative in regard to production lead time. NEC Corporation Revision 4.0 – July 24, 2015 17 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. NEC Corporation Revision 4.0 – July 24, 2015 18 CONFIGURATION GUIDE – 2U SAS JBOD Enclosure Revision History Revision Date Description 4.0 July 24, 2015 New products added: 2U 2.5-inch SAS JBOD Enclosure N8192-103F 600GB 10K Hot Plug 2.5-inch SAS HDD N8192-514 1.2TB 10K Hot Plug 2.5-inch SAS HDD N8192-516 1.8TB 10K Hot Plug 2.5-inch SAS HDD N8192-513 2U 3.5-inch SAS JBOD Enclosure N8192-104F 2TB 7.2K Hot Plug 3.5-inch NL SAS HDD N8192-520 4TB 7.2K Hot Plug 3.5-inch NL SAS HDD N8192-522 6TB 7.2K Hot Plug 3.5-inch NL SAS HDD N8192-519 Front Bezel N8192-303F External SATA Cable K410-333(02) 3.0 February 13, 2015 Other: Corrected the type of SAS cable to connect with N8103-179 RAID Controller and JBOD 2.0 January 30, 2015 New products added: RAID Controller (2GB, RAID0/1/5/6) / N8103-179 1.0 December 26, 2013 Initial release NEC Corporation Revision 4.0 – July 24, 2015 19