Preview only show first 10 pages with watermark. For full document please download

:**( 3 * (

   EMBED


Share

Transcript

:**( 3$&.$*('*$6(/(&75,& 352'8&763(&,),&$7,216 The Whirlpool Gold® brand WGGE45 packaged gas/electric unit uses the chlorine-free refrigerant R-410A and provides high-efficiency performance at reasonable operating costs. This unit is housed in a heavy-gauge, zinc-coated steel cabinet with a weather-resistant, powder-paint finish and allows for a ground-level or rooftop mount, horizontal or downflow application. 6WDQGDUG)HDWXUHV 6((5$)8(  721 6,1*/(3+$6( &22/,1*&$3$&,7<²%78+ +($7,1*&$3$&,7<²%78+ • Patented, heavy-duty stainless-steel heat exchanger for maximum efficiency • High-efficiency compressor with factory-installed sound blanket; two-stage compressor on 3-, 4-, and 5-ton models • EEM (energy-efficient) blower motor • Fully charged R-410A system • Copper tube, aluminum fin coils with TXV expansion device • Redundant two-stage gas valve; natural gas with easy conversion to propane • Power-assisted combustion • Direct-spark ignition system, including a microprocessorbased control for the entire ignition sequence • All blower operation and all safety circuits complete with self-diagnostics • Loss-of-charge protection and high-pressure switch • California Low NOx approved &DELQHW)HDWXUHV • Fully insulated heavy-gauge, zinc-coated steel cabinet with UV-resistant powder-paint finish • Compressor grommets for vibration isolation • All models fit in a standard-size pick-up truck • One roof curb fits all units • Convenient access panels • Bottom 2” high base rails for easier handling &RQWHQWV Nomenclature...................................................................... 2 Product Specifications ..................................................... 3 Evaporator Blower Specifications................................. 5 Expanded Cooling Data ................................................... 8 Dimensions.........................................................................32 Wiring Diagrams ..............................................................33 Accessories .........................................................................35 * To receive the Lifetime Compressor Limited Warranty, Lifetime Heat Exchanger Limited Warranty, and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. Full warranty details available at www.whirlpoolhvac.com. WGGE45.00 www.whirlpoolcomfort.com 1/12 352'8&763(&,),&$7,216 120(1&/$785( W 1 G 2 GE 3,4 4 5 5 6 37 7,8 A 9 090 10,11,12 Brand W Whirlpool M 13 Position M Multiposition H Horizontal Product Category G Gold 45 70 90 115 140 Unit Type GE Gas/Electric Refrigerant 4 R410A Heat Input 46 MBTU/h 69 MBTU/h 92 MBTU/h 115 MBTU/h 138 MBTU/h Electrical A 208-230/1/60 B 208-230/3/60 Efficiency 3 13 SEER 4 14 SEER 5 15 SEER Nominal Capacity 24 2 Tons 42 3½ Tons 30 2½ tons 49 4 Tons 37 3 Tons 60 5 Tons 3(5)250$1&(5$7,1*6 Model # WGGE4524A070M WGGE4530A090M WGGE4536A090M WGGE4537A090M WGGE4542A115M WGGE4548A115M WGGE4549A115M WGGE4560A140M Capacity (MBTU/h) SEER¹ 23,200 29,500 35,400 35,800 40,500 47,500 47,000 56,500 15 15 15 15 15 15 15 14 EER² 12 12.0 11 12.1 12.2 11 12 10.1 AHRI # 1184771 TBD 1184772 TBD TBD 1184773 TBD 1184774 ¹ Seasonal Energy Efficiency Ratio; Certified per AHRI 210/240 @ 80°F/ 67°F/ 95°F ² Energy Efficiency Ratio @ 80°F/ 67°F/ 95°F ,PSRUWDQW (QHUJ\6WDU 1RWLFH EnergyStar ratings are dependent upon conditions beyond equipment installation. Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet EnergyStar criteria. Ask your contractor for details or visit www.energystar.gov. 2 www.whirlpoolcomfort.com WGGE45.00 352'8&763(&,),&$7,216 63(&,),&$7,216 WGGE45 24A070M WGGE45 30A090M WGGE45 37A090M WGGE45 42A115M High-Stage Total ² ³ 23,200 29,500 35,800 40,500 Sensible ² ³ 18,500 22,500 26,300 30,300 12.0 12.0 12.1 12.2 --- --- --- --- 15.0 15.0 15.0 15.0 76 76 76 78 115,000 Cooling Capacity (BTU/h) EER ² ³ Low-Stage Total ² SEER Decibels Heating Capacity (BTU/h) High-Fire Input ² 69,000 92,000 92,000 High-Fire Output ² 55,000 72, 900 72,900 91,200 Low-Fire Input ¹ 51,500 69,000 69,000 86,000 Low-Fire Output ¹ 40,500 55,000 55,000 69,000 80.0 80.0 80.0 80.0 35 - 65 35-65 35-65 45-75 AFUE Temperature Rise Range No. of Burners 3.0 4 4 5 43 / 55 43 / 55 43 / 55 43 / 55 EEM (X-13) EEM (X-13) EEM (X-13) EEM (X-13) 10" x 8" 10" x 9" 10" x 9" 11 x 10 Indoor Nominal CFM 845 1,050 1,050 1,200 Motor Speed Tap (Cooling) T4 T3, T4 T3, T4 T3, T4 RPM / Amps (Cooling) 724 / 1.21 960 / 3.06 960 / 3.06 890 / 3.8 Horsepower / RPM Evaporator Coil ½ / 1,050 ½ / --- ½ / --- ¾ / --- Orifice Size (Gas / LP) Evaporator Motor Type Wheel (DxW) Face Area (ft²) 4.33 4.33 4.33 5.67 Rows Deep / Fin per Inch 2 / 14 3 / 14 4 / 14 4 / 14 Expansion Device TXV 0.065 TXV 0.072 Filter Size (ft²) 2.7 4.2 4.2 5.1 Drain Size (NPT) ¾" ¾" ¾" ¾" Refrigerant Charge -- R-410A (oz.) Condenser Fan 84 105 115 165 Horsepower - RPM 1/6 - 850 ¼ / 830 ¼ / 830 ¼ - 1,075 Fan Diameter / # of Fan Blades 22" / 3 22" / 3 22" / 3 22" / 3 Outdoor Nominal CFM Condenser Coil 2,400 2,700 2,700 3,500 Face Area (ft²) 12.3 12.3 12.3 15.3 Row Deep / Fins per Inch Electrical Data 1 / 22 2 / 16 2 / 16 2 / 16 Voltage/ Phase/ Frequency 208-230/ 1/ 60 208-230/1/60 208-230/1/60 208-230/1/60 13.5 / 58.3 14.1 / 73 16.7 / 79 17.9 / 112 4.1 1.85 1.85 2.87 1.1 / 1.7 1.5 / 3 1.5 / 3 1.4 / 2.9 Total Unit Amps 9.0 19.0 21.6 23.7 Min. Circuit Ampacity 22.1 21 24.2 26.6 Max. Overcurrent Protection 30 35 40 40 Entrance Size Power Supply 1¹⁄₈" 1¹⁄₈" 1¹⁄₈" 1¹⁄₈" Entrance Size Control Voltage Operating Weight (lbs) ⁷⁄₈" ⁷⁄₈" ⁷⁄₈" ⁷⁄₈" 417 453 458 538 480 560 Compressor RLA / LRA Indoor Blower FLA Oudoor Fan FLA / LRA Ship Weight (lbs) ¹ Single Stage ³ Outdoor Ambient Temperature @ 95°F WGGE45.00 439 475 ² Two Stage (or Single Stage 2-ton only) www.whirlpoolcomfort.com 3 352'8&763(&,),&$7,216 63(&,),&$7,216 &217 WGGE45 49A115M WGGE45 60A140M High-Stage Total ² ³ 47,000 56,500 Sensible ² ³ 34,000 44,000 Cooling Capacity (BTU/h) EER ² ³ 11.5 10.1 33,000 62,000 15.0 14.0 78 78 High-Fire Input ² 115,000 138,000 High-Fire Output ² 91,200 110,200 Low-Fire Input ¹ 86,000 103,500 Low-Fire Output ¹ 69,000 82,000 Low-Stage Total ² SEER Decibels Heating Capacity (BTU/h) AFUE 80.0 80.0 Temperature Rise Range 45-75 45 - 75 No. of Burners Orifice Size (Gas / LP) Evaporator Motor Type Wheel (DxW) 5 6.0 43 / 55 43 / 55 EEM (X-13) EEM (X-13) 11" x 10" 11" x 10" Indoor Nominal CFM 1,300 1,300 / 1,810 Motor Speed Tap (Cooling) T3, T4 T3, T4 778 / 1.98 1,030 / 5.7 1 / 1,050 RPM / Amps (Cooling) Horsepower / RPM Evaporator Coil 890 / 3.8 ¾ / --- Face Area (ft²) 5.67 5.67 Rows Deep / Fin per Inch 4 / 14 4 / 14 Expansion Device TXV TXV Filter Size (ft²) 5.1 6.3 Drain Size (NPT) ¾" ¾" Refrigerant Charge -- R-410A (oz.) Condenser Fan 170 180 ¹⁄₃ - 1,075 ¹⁄₃ - 1,075 Fan Diameter / # of Fan Blades 22" / 3 22" / 4 Outdoor Nominal CFM Condenser Coil 3,500 3,500 Horsepower - RPM Face Area (ft²) 15.3 15.3 Row Deep / Fins per Inch Electrical Data 2 / 16 2 / 16 Voltage/ Phase/ Frequency 208-230/1/60 208-230/1/60 21.2 / 96 25.8 / 118 Compressor RLA / LRA Indoor Blower FLA 2.87 7.6 1.4 / 2.9 2.4 / 5.2 Total Unit Amps 27.0 26.8 Min. Circuit Ampacity 30.8 42.1 Oudoor Fan FLA / LRA Max. Overcurrent Protection 50 60 Entrance Size Power Supply 1¹⁄₈" 1¹⁄₈" Entrance Size Control Voltage Operating Weight (lbs) ⁷⁄₈" ⁷⁄₈" 538 543 Ship Weight (lbs) 560 565 ¹ Single Stage ³ Outdoor Ambient Temperature @ 95°F 4 www.whirlpoolcomfort.com WGGE45.00 352'8&763(&,),&$7,216 (9$325$725%/2:(563(&,),&$7,216 WGGE4524A070M - Rise Range: 35° - 65° T1 - 1st Stage Heating T2 - 2nd Stage Heating T3 - Cooling Speed T4 - Cooling Speed T5 - Cooling Speed Unit Static CFM Watts Amps Rise CFM Watts Amps Rise CFM Watts Amps CFM Watts Amps CFM Watts Amps 0.1 742 84 0.75 52 907 134 1.18 57 857 116 1.04 907 134 1.18 1,040 185 1.33 0.2 677 89 0.82 57 857 140 1.24 61 816 126 1.16 857 140 1.24 988 198 1.40 0.3 631 97 0.90 62 814 149 1.32 64 760 131 1.18 814 149 1.32 949 208 1.42 0.4 575 101 0.92 X 761 154 1.33 X 721 140 1.25 761 154 1.33 903 213 1.49 0.5 526 111 1.01 X 727 165 1.41 X 670 145 1.31 727 165 1.41 871 222 1.55 0.6 - - - - 678 169 1.47 X 629 155 1.39 678 169 1.47 824 228 1.58 0.7 - - - - - - - - - - - - - - - - - 0.8 - - - - - - - - - - - - - - - - - WGGE4530A090M - Rise Range: 45° -75° T1 - 1st Stage Heating T2 - 2nd Stage Heating T3 - Cooling Speed T4 - Cooling Speed T5 - Cooling Speed Unit Static CFM Watts Amps Rise CFM Watts Amps Rise CFM Watts Amps CFM Watts Amps CFM Watts Amps 0.1 1,065 168 1.42 49 1,255 257 2.10 55 1,148 170 1.55 1,148 170 1.55 1,333 304 2.41 0.2 1,003 174 1.48 52 1,217 269 2.19 57 1,092 176 1.66 1,092 176 1.66 1,293 314 2.48 0.3 961 185 1.55 54 1,165 274 2.21 59 1,044 184 1.72 1,044 184 1.72 1,237 321 2.54 0.4 913 195 1.62 57 1,113 285 2.30 62 994 194 1.77 994 194 1.77 1,193 333 2.71 0.5 855 202 1.69 60 1,073 296 2.36 64 929 210 1.89 929 210 1.89 1,158 341 2.77 0.6 814 212 1.76 63 1,018 302 2.41 68 811 222 1.99 811 222 1.99 1,101 345 2.78 0.7 749 218 1.82 69 991 313 2.48 70 763 224 2.03 763 224 2.03 - - - 0.8 713 227 1.87 72 - - - - 715 236 2.07 715 236 2.07 - - - WGGE4537A090M - Rise Range: 45° -75° T1 - 1st Stage Heating T2 - 2nd Stage Heating T3 - Cooling Speed T4 - Cooling Speed T5 - Cooling Speed Unit Static CFM Watts Amps Rise CFM Watts Amps Rise CFM Watts Amps CFM Watts Amps CFM Watts Amps 0.1 1,065 168 1.42 49 1,255 257 2.10 55 1,148 170 1.55 1,148 170 1.55 1,418 360 2.92 0.2 1,003 174 1.48 52 1,217 269 2.19 57 1,092 176 1.66 1,092 176 1.66 1,375 371 3.00 0.3 961 185 1.55 54 1,165 274 2.21 59 1,044 184 1.72 1,044 184 1.72 1,316 376 3.05 0.4 913 195 1.62 57 1,113 285 2.30 62 994 194 1.77 994 194 1.77 1,279 387 3.13 0.5 855 202 1.69 60 1,073 296 2.36 64 929 210 1.89 929 210 1.89 1,245 392 3.19 0.6 814 212 1.76 63 1,018 302 2.41 68 811 222 1.99 811 222 1.99 1,193 400 3.22 0.7 749 218 1.82 69 991 313 2.48 70 763 224 2.03 763 224 2.03 - - - 0.8 713 227 1.87 72 - - - - 715 236 2.07 715 236 2.07 - - - WGGE45.00 www.whirlpoolcomfort.com 5 352'8&763(&,),&$7,216 (9$325$725%/2:(563(&,),&$7,216 &217 WGGE4542A115M - Rise Range: 45° -75° T1 - 1st Stage Heating Unit Static CFM 0.1 1,065 168 0.2 1,003 0.3 Watts Amps T2 - 2nd Stage Heating T3 - Cooling Speed T4 - Cooling Spped T5 - Cooling Spped Rise CFM Watts Amps Rise CFM Watts Amps CFM Watts Amps CFM Watts Amps 1.42 49 1,255 257 2.10 55 1,335 260 1.01 1,468 337 1.28 1,619 431 1.64 174 1.48 52 1,217 269 2.19 57 1,274 268 1.04 1,412 349 1.33 1,560 445 1.69 961 185 1.55 54 1,165 274 2.21 59 1,204 281 1.10 1,346 359 1.37 1,504 456 1.71 0.4 913 195 1.62 57 1,113 285 2.30 62 1,136 287 1.11 1,275 363 1.40 1,441 463 1.76 0.5 855 202 1.69 60 1,073 296 2.36 64 1,069 300 1.15 1,221 370 1.44 1,380 475 1.80 0.6 814 212 1.76 63 1,018 302 2.41 68 1,009 312 1.19 1,170 386 1.47 1,325 489 1.84 0.7 749 218 1.82 69 991 313 2.48 70 946 319 1.22 1,105 397 1.52 1,268 495 1.88 0.8 713 227 1.87 72 - - - - 886 331 1.27 1,042 406 1.54 1,198 502 1.90 WGGE4549A115M - Rise Range: 45° - 75° T1 - 1st Stage Heating T3 - 1st Stage Cooling T4 - 2nd Stage Cooling Rise CFM Watts Amps Rise CFM Watts Amps CFM Watts Amps CFM Watts Amps 1.52 56 1417 305 2.46 61 1,468 337 1.28 1,468 337 1.28 1,696 503 4.04 188 1.57 59 1374 318 2.56 63 1,412 349 1.33 1,412 349 1.33 1,650 517 4.15 199 1.67 62 1322 327 2.68 65 1,346 359 1.37 1,346 359 1.37 1,608 530 4.25 980 212 1.76 65 1273 338 2.72 68 1,275 363 1.40 1,275 363 1.40 1,566 543 4.39 0.5 914 220 1.79 70 1224 352 2.82 70 1,221 370 1.44 1,221 370 1.44 1,523 556 4.43 0.6 852 231 1.9 75 1176 365 2.88 73 1,170 386 1.47 1,170 386 1.47 1,480 569 4.55 0.7 806 242 1.97 X 1121 379 2.93 X 1,105 397 1.52 1,105 397 1.52 1,441 580 4.65 0.8 741 248 2.01 X 1068 391 2.98 X 1,042 406 1.54 1,042 406 1.54 - - - Unit Static CFM 0.1 1140 178 0.2 1090 0.3 1038 0.4 Watts Amps T2 - 2nd Stage Heating T5 - Cooling Spped WGGE4560A140M - Rise Range: 45° - 75° 6 T1 - 1st Stage Heating T2 - 2nd Stage Heating T3 - 1st Stage Cooling T4 - 2nd Stage Cooling T5 - Cooling Spped Unit Static CFM Rise CFM Watts Amps Rise CFM Watts Amps CFM Watts Amps CFM Watts 0.1 1773 488 3.64 X 1773 488 3.64 58 1,379 246 1.95 1,919 700 4.81 2,115 783 5.54 0.2 1713 501 3.73 45 1713 501 3.73 61 1,322 258 2.03 1,862 714 4.94 2,078 787 5.57 0.3 1693 509 3.78 45 1693 509 3.78 61 1,268 266 2.10 1,810 720 5.01 2,009 802 5.67 0.4 1653 518 3.84 46 1653 518 3.84 63 1,187 280 2.19 1,755 734 5.07 1,953 813 5.87 0.5 1597 529 3.91 48 1597 529 3.91 65 1,133 287 2.23 1,705 743 5.09 1,933 805 5.77 0.6 1534 541 3.99 50 1534 541 3.99 68 1,068 294 2.29 1,647 748 5.16 - - - 0.7 1485 552 4.09 52 1485 552 4.09 70 1,026 307 2.38 - - - - - - 0.8 - - - - - - - - - - - - - - - - - Watts Amps www.whirlpoolcomfort.com Amps WGGE45.00 352'8&763(&,),&$7,216 (9$325$725%/2:(563(&,),&$7,216 &217 WGGE45.00 www.whirlpoolcomfort.com 7 8 www.whirlpoolcomfort.com 23.1 0.89 20 1.52 7.1 229 110 22.4 0.85 21 1.51 7.0 227 109 20.7 0.82 21 1.47 6.9 220 106 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 739 845 951 59 22.7 0.78 17 1.51 7.0 227 109 22.1 0.75 18 1.49 7.0 224 108 20.4 0.72 18 1.46 6.8 218 105 Airflow MBh S/T ΔT 951 kW Amps Hi PR Lo PR MBh S/T ΔT 845 kW Amps Hi PR Lo PR MBh S/T ΔT 739 kW Amps Hi PR Lo PR 23.8 0.80 18 1.55 7.2 246 117 23.1 0.76 19 1.54 7.2 244 116 21.3 0.73 19 1.50 7.0 237 113 63 23.6 0.65 15 1.54 7.2 244 116 22.9 0.62 16 1.53 7.1 241 115 21.1 0.60 16 1.49 7.0 234 112 25.8 0.60 15 1.60 7.4 260 128 25.0 0.57 16 1.59 7.4 257 127 23.1 0.55 16 1.55 7.2 250 123 67 25.8 0.45 11 1.59 7.4 257 127 25.1 0.43 12 1.57 7.3 255 126 23.1 0.42 12 1.54 7.1 247 122 27.7 0.39 10 1.65 7.6 271 136 26.8 0.37 11 1.64 7.6 269 135 24.8 0.36 11 1.60 7.4 260 131 71 22.6 0.92 20 1.64 7.6 257 117 21.9 0.88 21 1.62 7.5 254 115 20.2 0.85 21 1.58 7.3 247 112 59 22.2 0.81 17 1.62 7.5 254 115 21.6 0.77 18 1.61 7.4 252 114 19.9 0.75 18 1.57 7.3 244 111 23.3 0.83 19 1.67 7.7 276 124 22.6 0.79 19 1.66 7.7 274 123 20.8 0.76 20 1.62 7.5 265 119 63 23.0 0.68 15 1.66 7.7 274 123 22.3 0.65 16 1.64 7.6 271 122 20.6 0.62 16 1.60 7.4 263 118 25.2 0.62 15 1.72 7.9 292 135 24.4 0.60 16 1.71 7.9 289 134 22.6 0.57 16 1.67 7.7 280 130 67 25.2 0.47 11 1.71 7.9 289 134 24.5 0.45 12 1.70 7.8 286 133 22.6 0.43 12 1.66 7.6 277 129 75ºF 27.0 0.40 10 1.78 8.2 304 144 26.2 0.38 11 1.77 8.1 301 143 24.2 0.37 11 1.72 7.9 292 138 71 22.0 0.95 20 1.74 8.1 292 121 21.4 0.90 21 1.72 8.0 289 120 19.8 0.87 21 1.68 7.9 280 116 59 21.7 0.83 17 1.72 8.0 289 120 21.0 0.79 18 1.71 8.0 286 119 19.4 0.77 18 1.67 7.8 278 115 22.7 0.85 19 1.78 8.3 314 129 22.0 0.81 19 1.76 8.2 311 128 20.3 0.78 20 1.72 8.0 302 124 24.6 0.64 15 1.84 8.5 332 141 23.9 0.61 16 1.82 8.4 329 139 22.0 0.59 16 1.77 8.2 319 135 26.4 0.41 11 1.90 8.8 346 150 25.6 0.39 11 1.88 8.7 343 148 23.6 0.38 11 1.83 8.5 332 144 22.1 0.87 19 1.87 8.7 358 135 21.5 0.83 19 1.86 8.7 354 134 19.8 0.80 20 1.81 8.5 344 130 24.0 0.66 15 1.93 9.0 378 148 23.3 0.63 16 1.92 8.9 374 146 21.5 0.61 16 1.87 8.7 363 142 kW = Total system power 21.5 0.98 20 1.83 8.6 333 127 20.9 0.93 21 1.82 8.5 329 126 19.3 0.90 22 1.77 8.3 319 122 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 22.5 24.6 21.1 21.9 24.0 0.70 0.48 0.86 0.72 0.50 15 11 18 15 12 1.76 1.82 1.82 1.86 1.92 8.2 8.4 8.5 8.7 8.9 311 328 329 354 374 128 139 126 134 146 21.8 23.9 20.5 21.3 23.3 0.66 0.46 0.82 0.68 0.47 16 12 18 16 12 1.75 1.80 1.80 1.84 1.90 8.1 8.4 8.4 8.6 8.9 308 325 326 351 370 126 138 125 133 145 20.1 22.1 19.0 19.6 21.5 0.64 0.44 0.79 0.66 0.46 16 12 19 16 12 1.70 1.76 1.76 1.79 1.85 8.0 8.2 8.2 8.4 8.6 299 315 316 340 359 123 134 121 129 140 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions. High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 25.7 0.43 11 2.00 9.3 394 157 25.0 0.41 11 1.98 9.2 390 156 23.1 0.39 11 1.93 9.0 379 151 71 20.4 1.00 20 1.91 9.0 374 133 19.8 0.97 21 1.89 9.0 370 132 18.3 0.93 21 1.84 8.8 359 128 59 20.1 0.89 17 1.89 9.0 370 132 19.5 0.85 18 1.88 8.9 367 131 18.0 0.82 18 1.83 8.7 356 127 21.0 0.91 18 1.95 9.2 403 142 20.4 0.86 19 1.93 9.2 399 140 18.9 0.83 20 1.89 8.9 387 136 63 20.8 0.74 15 1.93 9.2 399 140 20.2 0.71 16 1.92 9.1 395 139 18.7 0.69 16 1.87 8.9 383 135 22.8 0.69 15 2.02 9.5 425 155 22.1 0.65 16 2.00 9.4 421 153 20.4 0.63 16 1.95 9.2 408 149 67 22.8 0.52 11 2.00 9.4 421 153 22.2 0.49 12 1.98 9.3 417 152 20.4 0.47 12 1.93 9.1 404 147 105ºF 18.9 1.00 18 1.98 9.5 413 138 18.4 0.98 19 1.96 9.4 409 137 17.0 0.94 20 1.91 9.2 397 132 59 18.6 0.90 16 1.96 9.4 409 137 18.1 0.86 17 1.94 9.4 405 135 16.7 0.83 17 1.89 9.1 393 131 19.5 0.91 17 2.02 9.7 445 147 18.9 0.87 18 2.00 9.6 441 145 17.5 0.84 18 1.95 9.4 427 141 63 19.3 0.75 14 2.00 9.6 440 145 18.7 0.72 15 1.99 9.6 436 144 17.3 0.69 15 1.94 9.3 423 139 21.1 0.69 14 2.09 10.0 470 160 20.5 0.66 15 2.07 9.9 465 159 18.9 0.64 15 2.02 9.7 451 154 67 21.1 0.52 11 2.07 9.9 465 159 20.5 0.50 11 2.05 9.8 460 157 18.9 0.48 11 2.00 9.6 447 152 22.6 0.45 10 2.16 10.3 490 171 22.0 0.42 10 2.14 10.2 485 169 20.3 0.41 10 2.09 10.0 471 164 71 - Amps = outdoor unit amps (comp.+fan) 24.4 0.44 10 2.08 9.8 443 165 23.7 0.42 11 2.07 9.7 439 163 21.9 0.41 11 2.01 9.5 426 158 71 - 115ºF 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($ 0 WGGE45.00 WGGE45.00 www.whirlpoolcomfort.com 23.9 1.00 23 1.54 7.2 233 113 23.2 0.98 25 1.53 7.1 231 111 21.5 0.94 25 1.49 7.0 224 108 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 739 845 951 59 23.5 1.00 23 1.53 7.1 231 111 22.8 0.93 23 1.52 7.1 229 110 21.1 0.90 24 1.48 6.9 222 107 Airflow MBh S/T ΔT 951 kW Amps Hi PR Lo PR MBh S/T ΔT 845 kW Amps Hi PR Lo PR MBh S/T ΔT 739 kW Amps Hi PR Lo PR 24.4 0.99 23 1.58 7.3 251 120 23.7 0.94 24 1.56 7.3 249 119 21.9 0.91 25 1.53 7.1 241 115 63 24.0 0.92 21 1.56 7.3 249 119 23.3 0.87 22 1.55 7.2 246 117 21.5 0.84 23 1.51 7.1 239 114 25.6 0.89 22 1.63 7.5 265 131 24.8 0.85 23 1.61 7.5 263 129 22.9 0.82 23 1.57 7.3 255 126 67 25.7 0.75 19 1.61 7.5 263 129 24.9 0.71 19 1.60 7.4 260 128 23.0 0.69 20 1.56 7.3 252 124 27.3 0.72 19 1.68 7.8 277 139 26.5 0.69 20 1.66 7.7 274 138 24.4 0.67 20 1.62 7.5 266 134 71 27.5 0.56 15 1.66 7.7 274 138 26.7 0.53 15 1.65 7.7 271 136 24.6 0.51 16 1.61 7.5 263 132 23.4 1.00 23 1.66 7.7 262 119 22.7 1.00 25 1.65 7.6 259 118 21.0 0.98 25 1.61 7.4 252 114 59 23.0 1.00 22 1.65 7.6 259 118 22.3 0.97 23 1.64 7.6 257 117 20.6 0.93 24 1.60 7.4 249 113 23.8 1.00 23 1.70 7.8 282 126 23.1 0.98 25 1.68 7.8 279 125 21.4 0.94 25 1.64 7.6 271 121 63 23.5 0.95 22 1.68 7.8 279 125 22.8 0.91 22 1.67 7.7 276 124 21.0 0.87 23 1.63 7.5 268 120 25.0 0.92 22 1.75 8.0 298 138 24.2 0.88 23 1.74 8.0 295 137 22.4 0.85 24 1.70 7.8 286 133 67 25.1 0.77 19 1.74 8.0 295 137 24.4 0.74 20 1.73 7.9 292 135 22.5 0.71 20 1.68 7.7 283 131 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 26.6 0.75 19 1.81 8.3 310 147 25.9 0.72 20 1.80 8.2 307 146 23.9 0.69 20 1.75 8.0 298 141 71 26.8 0.58 15 1.80 8.2 307 146 26.0 0.55 16 1.78 8.2 304 144 24.0 0.53 16 1.74 8.0 295 140 22.8 1.00 22 1.77 8.2 298 124 22.2 1.00 24 1.75 8.2 295 122 20.5 1.00 25 1.71 8.0 286 119 59 22.4 1.00 22 1.75 8.2 295 122 21.8 0.99 23 1.74 8.1 292 121 20.1 0.95 24 1.70 7.9 283 118 23.3 1.00 23 1.81 8.4 321 131 22.6 1.00 25 1.79 8.3 317 130 20.9 0.97 25 1.75 8.1 308 126 24.4 0.95 22 1.87 8.6 339 144 23.7 0.90 23 1.85 8.6 335 142 21.8 0.87 24 1.80 8.4 325 138 22.3 1.00 22 1.86 8.7 339 130 21.6 1.00 24 1.85 8.6 336 129 20.0 1.00 25 1.80 8.4 326 125 22.7 1.00 22 1.90 8.9 365 138 22.0 1.00 24 1.89 8.8 362 137 20.3 1.00 25 1.84 8.6 351 133 23.8 0.98 22 1.97 9.1 386 151 23.1 0.93 23 1.95 9.1 382 149 21.3 0.90 24 1.90 8.9 370 145 25.4 0.79 19 2.03 9.4 402 161 24.6 0.76 20 2.01 9.4 398 159 22.7 0.73 21 1.96 9.1 386 154 71 25.5 0.61 15 2.01 9.4 398 159 24.8 0.58 16 2.00 9.3 394 157 22.9 0.56 16 1.95 9.1 382 153 Shaded area reflects AHRI conditions 26.0 0.77 19 1.93 8.9 353 153 25.2 0.73 20 1.91 8.8 350 151 23.3 0.71 20 1.86 8.6 339 147 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 22.9 24.5 26.2 21.9 22.4 23.9 1.00 0.79 0.59 1.00 1.00 0.82 22 19 15 21 22 19 1.79 1.85 1.91 1.85 1.89 1.95 8.3 8.6 8.8 8.6 8.8 9.1 317 335 350 336 362 382 130 142 151 129 137 149 22.3 23.8 25.4 21.3 21.7 23.2 0.93 0.76 0.56 1.00 0.96 0.78 20 22 20 16 23 23 1.78 1.84 1.90 1.83 1.87 1.93 9.0 8.3 8.5 8.8 8.6 8.8 314 332 346 333 358 378 129 141 150 127 135 148 20.5 21.9 23.5 19.6 20.0 21.4 0.90 0.73 0.54 0.99 0.92 0.75 23 20 16 24 23 20 1.73 1.79 1.85 1.78 1.82 1.88 8.1 8.3 8.6 8.4 8.5 8.8 305 322 336 323 347 367 125 136 145 123 131 143 21.2 1.00 20 1.94 9.2 382 136 20.5 1.00 22 1.92 9.1 378 135 19.0 1.00 24 1.88 8.9 367 131 59 20.8 1.00 20 1.92 9.1 378 135 20.2 1.00 22 1.91 9.0 374 133 18.6 1.02 24 1.86 8.8 363 129 21.6 1.00 21 1.98 9.4 411 145 20.9 1.00 23 1.97 9.3 407 143 19.3 1.00 24 1.92 9.1 395 139 63 21.2 1.00 21 1.97 9.3 407 143 20.6 0.99 22 1.95 9.2 403 142 19.0 0.96 23 1.90 9.0 391 138 22.6 1.00 22 2.05 9.7 434 158 21.9 0.97 23 2.03 9.6 430 156 20.2 0.93 23 1.98 9.3 417 152 67 22.7 0.85 19 2.03 9.6 430 156 22.0 0.81 19 2.02 9.5 425 155 20.3 0.78 20 1.96 9.3 412 150 105ºF 19.6 1.00 19 2.01 9.7 422 141 19.0 1.00 21 1.99 9.6 418 139 17.6 1.00 22 1.94 9.3 405 135 59 19.3 1.00 19 1.99 9.6 418 139 18.7 1.00 20 1.98 9.5 413 138 17.3 1.03 22 1.93 9.3 401 134 20.0 1.00 19 2.05 9.9 454 150 19.4 1.00 21 2.04 9.8 449 148 17.9 1.00 22 1.99 9.5 436 144 63 19.7 1.00 19 2.04 9.8 449 148 19.1 1.00 21 2.02 9.7 445 147 17.6 0.97 21 1.97 9.5 432 142 20.9 1.00 20 2.12 10.2 479 163 20.3 0.98 22 2.11 10.1 475 162 18.7 0.94 22 2.05 9.8 460 157 67 21.0 0.86 17 2.11 10.1 475 162 20.4 0.82 18 2.09 10.0 470 160 18.8 0.79 18 2.03 9.7 456 155 22.3 0.83 18 2.20 10.5 500 174 21.7 0.79 19 2.18 10.4 495 172 20.0 0.76 19 2.12 10.2 480 167 71 22.5 0.64 14 2.18 10.4 495 172 21.8 0.61 14 2.16 10.3 490 171 20.1 0.59 15 2.10 10.1 475 165 Amps = outdoor unit amps (comp.+fan) kW = Total system power 24.1 0.82 19 2.12 10.0 452 168 23.4 0.79 20 2.10 9.9 448 167 21.6 0.76 20 2.05 9.7 435 162 71 24.3 0.63 15 2.10 9.9 448 167 23.6 0.61 16 2.08 9.8 444 165 21.7 0.58 16 2.03 9.6 430 160 115ºF 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($ 0 &217 9 10 www.whirlpoolcomfort.com 29.4 0.87 21 1.86 9.0 228 106 28.5 0.83 22 1.85 9.0 226 105 26.3 0.80 22 1.80 8.8 219 102 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 875 1000 1125 59 28.9 0.76 18 1.85 9.0 226 105 28.1 0.73 19 1.83 8.9 223 104 25.9 0.70 19 1.79 8.7 217 101 Airflow MBh S/T ΔT 1125 kW Amps Hi PR Lo PR MBh S/T ΔT 1000 kW Amps Hi PR Lo PR MBh S/T ΔT 875 kW Amps Hi PR Lo PR 30.3 0.78 19 1.90 9.2 245 113 29.4 0.74 20 1.89 9.1 243 112 27.1 0.71 20 1.84 9.0 236 109 63 30.0 0.64 16 1.89 9.1 243 112 29.1 0.61 16 1.87 9.1 240 111 26.8 0.59 17 1.83 8.9 233 108 32.8 0.59 16 1.96 9.4 259 124 31.8 0.56 16 1.95 9.4 257 122 29.4 0.54 17 1.90 9.2 249 119 67 32.8 0.44 12 1.94 9.4 256 122 31.9 0.42 12 1.93 9.3 254 121 29.4 0.41 13 1.88 9.1 246 118 35.2 0.38 11 2.02 9.7 270 132 34.1 0.36 11 2.01 9.6 268 130 31.5 0.35 12 1.96 9.4 260 126 71 28.7 0.90 21 2.00 9.6 256 112 27.9 0.86 22 1.99 9.5 253 111 25.7 0.83 22 1.94 9.3 246 108 59 28.2 0.79 18 1.99 9.5 253 111 27.4 0.76 19 1.97 9.5 251 110 25.3 0.73 19 1.92 9.3 243 107 29.6 0.81 19 2.05 9.8 275 120 28.7 0.77 20 2.03 9.7 273 118 26.5 0.74 21 1.98 9.5 264 115 63 29.3 0.66 16 2.03 9.7 273 118 28.4 0.63 16 2.01 9.6 270 117 26.2 0.61 17 1.97 9.4 262 114 32.0 0.61 16 2.11 10.0 291 131 31.1 0.58 17 2.10 10.0 288 129 28.7 0.56 17 2.04 9.8 279 125 67 32.1 0.46 12 2.09 10.0 288 129 31.1 0.44 13 2.08 9.9 285 128 28.7 0.42 13 2.03 9.7 276 124 75ºF IDB: Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 28.0 0.92 21 2.13 10.3 291 117 27.2 0.88 22 2.11 10.2 288 116 25.1 0.85 22 2.06 10.0 279 112 59 27.6 0.81 18 2.11 10.2 288 116 26.8 0.78 19 2.09 10.1 285 115 24.7 0.75 19 2.04 9.9 277 111 28.9 0.83 19 2.18 10.5 313 124 28.0 0.79 20 2.16 10.4 310 123 25.9 0.76 21 2.11 10.2 301 119 31.2 0.63 16 2.25 10.7 331 136 30.3 0.60 17 2.23 10.7 327 134 28.0 0.58 17 2.17 10.4 318 130 33.5 0.40 11 2.32 11.1 345 145 32.6 0.38 11 2.30 11.0 341 143 30.0 0.37 12 2.24 10.7 331 139 27.3 0.95 21 2.24 10.8 331 123 26.6 0.91 22 2.22 10.7 328 122 24.5 0.88 23 2.17 10.5 318 118 Shaded area reflects ACCA (TVA) conditions 34.3 0.39 11 2.18 10.3 303 139 33.3 0.37 11 2.16 10.3 300 138 30.8 0.36 12 2.11 10.0 291 134 71 28.2 0.85 20 2.29 11.0 357 131 27.3 0.81 20 2.27 11.0 353 129 25.2 0.78 21 2.21 10.7 343 125 32.7 0.42 11 2.44 11.7 393 152 31.8 0.40 12 2.42 11.6 389 150 29.3 0.38 12 2.36 11.3 377 146 71 26.0 0.99 21 2.33 11.4 373 129 25.2 0.94 22 2.31 11.3 369 127 23.3 0.91 22 2.26 11.0 358 124 59 25.5 0.87 18 2.31 11.3 369 127 24.8 0.83 19 2.30 11.2 365 126 22.9 0.80 19 2.24 11.0 354 122 26.7 0.89 19 2.39 11.6 401 137 26.0 0.84 20 2.37 11.5 397 136 24.0 0.81 21 2.31 11.3 385 132 63 26.5 0.73 16 2.37 11.5 397 136 25.7 0.69 16 2.35 11.4 393 134 23.7 0.67 17 2.29 11.2 381 130 29.0 0.67 16 2.46 11.9 424 149 28.1 0.64 17 2.44 11.8 419 148 25.9 0.62 17 2.38 11.6 407 144 67 29.0 0.50 12 2.44 11.8 419 148 28.2 0.48 12 2.42 11.8 415 147 26.0 0.46 13 2.36 11.5 403 142 105ºF 31.1 0.43 11 2.55 12.3 442 159 30.2 0.41 11 2.53 12.2 438 158 27.8 0.40 12 2.46 11.9 424 153 71 24.1 1.00 20 2.41 11.9 412 133 23.4 0.95 20 2.39 11.8 408 132 21.6 0.92 21 2.34 11.6 396 128 59 23.7 0.88 17 2.39 11.8 408 132 23.0 0.84 18 2.37 11.8 404 130 21.2 0.81 18 2.32 11.5 392 127 24.8 0.89 18 2.47 12.2 443 142 24.1 0.85 19 2.45 12.1 439 140 22.2 0.82 19 2.39 11.8 426 136 63 24.5 0.73 15 2.45 12.1 439 140 23.8 0.70 15 2.43 12.0 434 139 22.0 0.67 16 2.37 11.7 421 135 26.8 0.68 15 2.55 12.5 468 155 26.0 0.64 15 2.53 12.4 463 153 24.0 0.62 16 2.47 12.1 450 148 67 26.9 0.51 11 2.53 12.4 463 153 26.1 0.48 12 2.51 12.3 459 152 24.1 0.47 12 2.44 12.0 445 147 115ºF 28.8 0.43 10 2.64 12.9 488 165 27.9 0.41 11 2.61 12.8 483 163 25.8 0.40 11 2.55 12.5 469 158 71 - Design Subcooling, 7° F @ liquid access fitting connection AHRI 95 test conditions; Superheat 5° F @ compressor suction access fitting connection. 30.5 0.65 16 2.36 11.3 377 143 29.6 0.62 17 2.34 11.2 373 141 27.3 0.59 17 2.29 11.0 362 137 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 28.6 31.3 26.9 27.9 30.5 0.68 0.47 0.84 0.70 0.49 16 12 18 16 12 2.16 2.23 2.22 2.27 2.34 10.4 10.7 10.7 11.0 11.2 310 327 328 353 373 123 134 122 129 141 27.7 30.4 26.1 27.1 29.6 0.65 0.45 0.80 0.67 0.46 17 13 19 17 13 2.14 2.21 2.20 2.25 2.32 10.3 10.6 10.7 10.9 11.2 307 324 325 350 369 122 133 120 128 140 25.6 28.0 24.1 25.0 27.4 0.62 0.43 0.77 0.64 0.45 17 13 20 17 13 2.09 2.15 2.15 2.20 2.27 10.1 10.3 10.4 10.6 10.9 298 314 315 339 358 118 129 117 124 136 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($0 WGGE45.00 WGGE45.00 www.whirlpoolcomfort.com 30.4 1.00 25 1.89 9.2 233 109 29.6 0.95 26 1.88 9.1 230 108 27.3 0.92 26 1.83 8.9 223 104 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 875 1000 1125 59 29.9 0.95 23 1.88 9.1 230 108 29.0 0.91 24 1.86 9.0 228 106 26.8 0.88 25 1.82 8.9 221 103 Airflow MBh S/T ΔT 1125 kW Amps Hi PR Lo PR MBh S/T ΔT 1000 kW Amps Hi PR Lo PR MBh S/T ΔT 875 kW Amps Hi PR Lo PR 31.0 0.96 24 1.93 9.3 250 116 30.1 0.92 25 1.92 9.3 248 114 27.8 0.89 26 1.87 9.1 240 111 63 30.6 0.89 22 1.92 9.3 248 114 29.7 0.85 23 1.90 9.2 245 113 27.4 0.82 24 1.86 9.0 238 110 32.5 0.87 23 1.99 9.6 264 126 31.6 0.83 24 1.98 9.5 262 125 29.1 0.80 24 1.93 9.3 254 121 67 32.7 0.73 19 1.98 9.5 262 125 31.7 0.69 20 1.96 9.4 259 124 29.3 0.67 21 1.91 9.2 251 120 34.7 0.71 20 2.06 9.9 276 134 33.7 0.67 21 2.04 9.8 273 133 31.1 0.65 21 1.99 9.6 265 129 71 34.9 0.54 16 2.04 9.8 273 133 33.9 0.52 16 2.02 9.7 270 132 31.3 0.50 16 1.97 9.5 262 128 29.7 1.00 24 2.04 9.7 261 115 28.9 0.99 26 2.02 9.7 258 114 26.6 0.95 27 1.97 9.5 251 110 59 29.2 1.00 24 2.02 9.7 258 114 28.4 0.94 25 2.00 9.6 256 113 26.2 0.91 25 1.96 9.4 248 109 30.3 1.00 25 2.08 9.9 281 122 29.4 0.95 26 2.06 9.9 278 121 27.2 0.92 26 2.01 9.6 270 117 63 29.9 0.93 23 2.06 9.9 278 121 29.0 0.88 24 2.05 9.8 275 120 26.8 0.85 24 2.00 9.6 267 116 31.7 0.90 23 2.15 10.2 297 133 30.8 0.86 24 2.13 10.1 294 132 28.4 0.83 25 2.08 9.9 285 128 67 31.9 0.75 20 2.13 10.1 294 132 31.0 0.72 20 2.11 10.0 291 131 28.6 0.69 21 2.06 9.8 282 127 75ºF IDB: Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 29.0 1.00 24 2.16 10.4 297 119 28.2 1.00 26 2.15 10.3 294 118 26.0 0.98 27 2.09 10.1 285 115 59 28.5 1.00 23 2.15 10.3 294 118 27.7 0.97 25 2.13 10.3 291 117 25.6 0.93 25 2.08 10.0 282 113 29.6 1.00 24 2.21 10.6 319 127 28.7 0.98 26 2.19 10.5 316 126 26.5 0.94 26 2.14 10.3 307 122 31.0 0.92 23 2.28 10.9 337 139 30.1 0.88 24 2.26 10.8 334 137 27.8 0.85 25 2.21 10.6 324 133 33.1 0.75 20 2.36 11.2 352 148 32.1 0.72 21 2.34 11.1 348 146 29.6 0.69 21 2.28 10.9 338 142 Shaded area reflects AHRI conditions 33.9 0.73 20 2.22 10.5 309 142 32.9 0.70 21 2.20 10.4 306 141 30.3 0.67 21 2.14 10.2 297 136 71 34.1 0.56 16 2.20 10.4 306 141 33.1 0.54 16 2.18 10.3 303 139 30.6 0.52 17 2.13 10.1 294 135 28.3 1.00 23 2.28 11.0 338 125 27.5 1.00 25 2.26 10.9 335 124 25.4 1.00 27 2.20 10.7 325 120 28.9 1.00 24 2.33 11.2 364 133 28.0 1.00 26 2.31 11.1 360 132 25.9 0.97 26 2.25 10.9 349 128 32.3 0.77 20 2.48 11.9 401 155 31.3 0.74 21 2.46 11.8 397 153 28.9 0.71 22 2.40 11.5 385 149 71 32.5 0.60 16 2.46 11.8 397 153 31.5 0.57 16 2.44 11.7 393 152 29.1 0.55 17 2.38 11.4 381 147 26.9 1.00 22 2.37 11.6 380 131 26.1 1.00 24 2.35 11.5 377 130 24.1 1.00 25 2.29 11.2 365 126 59 26.4 1.00 22 2.35 11.5 377 130 25.7 1.00 24 2.33 11.4 373 129 23.7 1.00 25 2.28 11.1 362 125 27.4 1.00 22 2.43 11.8 409 140 26.6 1.00 24 2.41 11.7 405 138 24.6 1.00 26 2.35 11.4 393 134 63 27.0 1.00 22 2.41 11.7 405 138 26.2 0.97 23 2.39 11.6 401 137 24.2 0.94 24 2.33 11.3 389 133 28.7 0.99 23 2.51 12.1 432 153 27.9 0.95 24 2.48 12.0 428 151 25.7 0.91 25 2.42 11.7 415 146 67 28.9 0.83 20 2.48 12.0 428 151 28.0 0.79 20 2.46 11.9 424 149 25.9 0.76 21 2.40 11.7 411 145 105ºF 30.6 0.80 20 2.59 12.5 451 162 29.7 0.77 21 2.57 12.4 446 161 27.5 0.74 21 2.50 12.1 433 156 71 30.9 0.62 16 2.57 12.4 446 161 30.0 0.59 16 2.55 12.3 442 159 27.7 0.57 17 2.48 12.0 429 154 24.9 1.00 20 2.46 12.1 420 136 24.2 1.00 22 2.44 12.0 416 134 22.3 1.00 23 2.37 11.8 404 130 59 24.5 1.00 20 2.44 12.0 416 134 23.8 1.00 22 2.42 11.9 412 133 21.9 1.01 23 2.35 11.7 400 129 25.4 1.00 21 2.51 12.4 452 144 24.7 1.00 23 2.49 12.3 448 143 22.8 1.00 24 2.43 12.0 434 139 63 25.0 1.00 20 2.49 12.3 448 143 24.3 0.98 22 2.47 12.2 443 142 22.4 0.94 22 2.41 11.9 430 137 26.6 1.00 22 2.59 12.7 478 158 25.8 0.95 23 2.57 12.6 473 156 23.8 0.92 23 2.51 12.3 459 151 67 26.7 0.84 18 2.57 12.6 473 156 26.0 0.80 19 2.55 12.5 468 155 24.0 0.77 19 2.49 12.2 454 150 115ºF 28.4 0.81 19 2.68 13.1 498 168 27.6 0.77 20 2.66 13.0 493 166 25.4 0.75 20 2.59 12.7 478 161 71 28.6 0.62 15 2.66 13.0 493 166 27.8 0.60 15 2.64 12.9 488 165 25.6 0.57 15 2.57 12.6 474 160 Design Subcooling, 7 °F @ liquid access fitting connection AHRI 95 test conditions; Superheat 5°F @ compressor suction access fitting connection. 30.2 0.95 24 2.40 11.5 384 146 29.4 0.91 25 2.38 11.4 380 144 27.1 0.88 25 2.32 11.2 369 140 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 29.2 31.1 33.3 27.8 28.4 30.4 0.95 0.77 0.58 1.00 1.00 0.80 23 20 16 23 23 20 2.19 2.26 2.34 2.26 2.31 2.38 10.5 10.8 11.1 10.9 11.1 11.4 316 334 348 335 360 380 126 137 146 124 132 144 28.3 30.2 32.3 27.0 27.6 29.5 0.91 0.74 0.55 1.00 0.94 0.76 21 24 21 16 25 24 2.18 2.25 2.32 2.24 2.29 2.36 10.5 10.7 11.1 10.8 11.0 11.3 313 331 345 331 357 377 124 136 145 123 131 143 26.1 27.9 29.8 24.9 25.5 27.2 0.87 0.71 0.53 0.96 0.90 0.73 24 21 17 25 24 21 2.12 2.19 2.26 2.18 2.23 2.31 10.2 10.5 10.8 10.6 10.8 11.1 304 321 335 322 346 365 121 132 140 119 127 138 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($0 &217 11 12 www.whirlpoolcomfort.com 35.0 0.80 23 2.31 11.0 238 106 34.6 0.79 24 2.30 11.0 237 105 32.0 0.76 26 2.24 10.8 230 102 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 875 1055 1125 59 34.4 0.71 20 2.29 11.0 235 104 34.1 0.69 21 2.28 10.9 235 104 31.4 0.67 22 2.23 10.7 228 101 Airflow MBh S/T ΔT 1125 kW Amps Hi PR Lo PR MBh S/T ΔT 1055 kW Amps Hi PR Lo PR MBh S/T ΔT 875 kW Amps Hi PR Lo PR 36.0 0.72 21 2.36 11.3 256 112 35.7 0.71 22 2.35 11.2 255 112 32.9 0.68 24 2.29 11.0 247 109 63 35.7 0.59 17 2.34 11.2 253 111 35.3 0.58 18 2.33 11.2 253 111 32.6 0.56 19 2.27 10.9 245 107 39.0 0.54 17 2.43 11.6 270 123 38.6 0.53 18 2.43 11.5 269 122 35.6 0.51 19 2.37 11.3 261 119 67 39.1 0.41 13 2.41 11.5 267 121 38.7 0.40 14 2.41 11.5 267 121 35.7 0.39 15 2.35 11.2 259 117 41.8 0.35 12 2.51 11.9 282 131 41.4 0.34 12 2.51 11.9 281 130 38.2 0.33 13 2.44 11.6 273 126 71 34.2 0.83 23 2.49 11.8 267 111 33.8 0.82 24 2.48 11.8 266 111 31.2 0.79 26 2.42 11.5 258 108 59 33.6 0.73 20 2.47 11.7 264 110 33.3 0.72 21 2.46 11.7 263 110 30.7 0.69 22 2.40 11.4 255 107 35.2 0.75 21 2.54 12.0 287 119 34.8 0.73 22 2.54 12.0 286 118 32.2 0.71 24 2.47 11.7 278 115 63 34.8 0.61 17 2.52 11.9 284 117 34.5 0.60 18 2.51 11.9 283 117 31.8 0.58 19 2.45 11.6 275 114 38.1 0.56 18 2.63 12.4 303 129 37.7 0.55 18 2.62 12.3 302 129 34.8 0.53 20 2.55 12.0 293 125 67 38.2 0.42 13 2.60 12.3 300 128 37.8 0.42 14 2.60 12.2 299 128 34.9 0.40 15 2.53 11.9 290 124 75ºF IDB: Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 33.4 0.85 23 2.65 12.6 303 116 33.0 0.84 24 2.64 12.6 303 116 30.5 0.81 26 2.57 12.3 293 112 59 32.8 0.75 20 2.63 12.5 300 115 32.5 0.74 21 2.62 12.5 299 114 30.0 0.71 22 2.55 12.2 290 111 34.3 0.76 21 2.71 12.9 327 123 34.0 0.75 22 2.70 12.9 326 123 31.4 0.72 24 2.63 12.6 316 119 37.2 0.58 18 2.80 13.3 345 135 36.8 0.57 18 2.79 13.2 344 134 34.0 0.55 20 2.72 12.9 333 130 39.9 0.37 12 2.89 13.7 360 143 39.5 0.37 13 2.88 13.7 359 143 36.5 0.35 13 2.81 13.3 348 139 32.5 0.88 23 2.79 13.4 346 122 32.2 0.87 24 2.78 13.3 345 121 29.7 0.83 26 2.71 13.0 334 118 Shaded area reflects ACCA (TVA) conditions 40.9 0.36 12 2.71 12.7 316 138 40.5 0.36 13 2.71 12.7 315 137 37.3 0.34 13 2.64 12.4 306 133 71 33.5 0.79 22 2.85 13.7 372 129 33.2 0.77 22 2.85 13.6 371 129 30.6 0.75 24 2.77 13.3 360 125 38.9 0.38 12 3.05 14.5 410 151 38.5 0.38 13 3.04 14.5 408 150 35.6 0.36 14 2.96 14.1 396 146 71 30.9 0.92 23 2.91 14.1 389 128 30.6 0.90 24 2.90 14.1 388 127 28.3 0.87 26 2.83 13.7 376 123 59 30.4 0.81 20 2.88 14.0 385 126 30.1 0.79 21 2.88 14.0 384 126 27.8 0.76 22 2.80 13.6 372 122 31.8 0.82 21 2.98 14.4 418 136 31.5 0.80 22 2.97 14.4 417 135 29.1 0.77 24 2.89 14.0 405 131 63 31.5 0.67 17 2.95 14.3 414 134 31.2 0.66 18 2.94 14.3 413 134 28.8 0.64 19 2.87 13.9 401 130 34.5 0.62 17 3.08 14.8 442 148 34.1 0.61 18 3.07 14.8 440 148 31.5 0.59 19 2.99 14.4 427 143 67 34.5 0.47 13 3.05 14.7 437 147 34.2 0.46 14 3.04 14.7 436 146 31.5 0.44 15 2.96 14.3 423 142 105ºF 37.0 0.40 12 3.18 15.3 461 158 36.6 0.39 12 3.17 15.3 459 157 33.8 0.38 13 3.09 14.9 446 153 71 28.6 0.92 22 3.01 14.8 430 132 28.4 0.91 22 3.01 14.8 428 132 26.2 0.87 24 2.93 14.4 415 128 59 28.2 0.81 19 2.99 14.7 425 131 27.9 0.80 19 2.98 14.7 424 130 25.7 0.77 21 2.90 14.3 411 126 29.5 0.83 20 3.08 15.2 462 140 29.2 0.81 21 3.07 15.1 461 140 26.9 0.78 22 3.00 14.8 447 136 63 29.2 0.68 16 3.06 15.0 458 139 28.9 0.67 17 3.05 15.0 456 139 26.7 0.64 18 2.97 14.6 443 134 31.9 0.63 16 3.19 15.6 488 153 31.6 0.61 17 3.18 15.6 487 153 29.2 0.59 18 3.10 15.2 472 148 67 32.0 0.47 12 3.16 15.5 483 152 31.7 0.46 13 3.15 15.4 482 151 29.2 0.44 14 3.07 15.1 467 147 115ºF 34.3 0.40 11 3.30 16.1 509 163 33.9 0.39 12 3.29 16.1 508 163 31.3 0.38 13 3.20 15.7 492 158 71 - Design Subcooling, 10° F @ liquid access fitting connection AHRI 95 test conditions; Superheat 6° F @ compressor suction access fitting connection. 36.3 0.60 18 2.95 14.0 393 141 35.9 0.59 18 2.94 14.0 392 141 33.1 0.56 20 2.87 13.7 380 137 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 34.0 37.2 32.0 33.2 36.3 0.63 0.44 0.78 0.65 0.45 17 13 20 18 13 2.68 2.77 2.77 2.83 2.92 12.8 13.2 13.3 13.5 13.9 323 341 342 368 389 122 133 120 128 140 33.7 36.9 31.7 32.8 36.0 0.62 0.43 0.76 0.64 0.44 18 14 21 18 14 2.68 2.77 2.76 2.82 2.92 12.8 13.1 13.2 13.5 13.9 322 340 341 367 388 122 133 120 128 140 31.1 34.0 29.2 30.3 33.2 0.59 0.41 0.73 0.61 0.42 19 15 23 20 15 2.61 2.70 2.69 2.75 2.84 12.5 12.8 12.9 13.2 13.6 313 330 331 356 376 118 129 117 124 135 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($0 WGGE45.00 WGGE45.00 www.whirlpoolcomfort.com 36.2 0.93 27 2.34 11.2 243 108 35.9 0.91 28 2.34 11.2 242 107 33.1 0.87 30 2.28 10.9 235 104 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 875 1055 1125 59 35.6 0.88 26 2.32 11.1 240 107 35.3 0.87 27 2.32 11.1 239 106 32.5 0.83 29 2.26 10.9 232 103 Airflow MBh S/T ΔT 1125 kW Amps Hi PR Lo PR MBh S/T ΔT 1055 kW Amps Hi PR Lo PR MBh S/T ΔT 875 kW Amps Hi PR Lo PR 36.9 0.89 27 2.39 11.4 261 115 36.6 0.88 28 2.39 11.4 260 114 33.7 0.84 30 2.33 11.1 252 111 63 36.4 0.83 25 2.37 11.3 258 113 36.0 0.81 25 2.37 11.3 258 113 33.2 0.78 27 2.31 11.1 250 110 38.7 0.81 25 2.47 11.7 276 125 38.3 0.79 26 2.47 11.7 275 125 35.3 0.76 28 2.40 11.5 267 121 67 38.9 0.67 21 2.45 11.7 273 124 38.5 0.66 22 2.45 11.6 272 123 35.5 0.64 24 2.39 11.4 264 120 41.3 0.65 22 2.55 12.1 288 133 40.9 0.64 23 2.55 12.1 287 133 37.7 0.62 24 2.48 11.8 278 129 71 41.6 0.50 17 2.53 12.0 285 132 41.1 0.49 18 2.53 12.0 284 131 38.0 0.48 19 2.46 11.7 275 127 35.4 0.96 28 2.53 12.0 272 114 35.0 0.94 29 2.52 11.9 271 113 32.3 0.91 31 2.46 11.7 263 110 59 34.8 0.91 26 2.51 11.9 269 113 34.4 0.90 27 2.50 11.8 269 112 31.8 0.86 29 2.44 11.6 261 109 36.1 0.93 27 2.58 12.2 293 121 35.7 0.91 28 2.58 12.2 292 121 33.0 0.87 30 2.51 11.9 283 117 63 35.5 0.86 25 2.56 12.1 290 120 35.2 0.84 26 2.56 12.1 289 119 32.5 0.81 28 2.49 11.8 280 116 37.8 0.83 26 2.67 12.5 309 132 37.4 0.82 27 2.66 12.5 308 132 34.5 0.79 29 2.60 12.2 299 128 67 38.0 0.70 22 2.65 12.4 306 131 37.6 0.68 22 2.64 12.4 305 130 34.7 0.66 24 2.57 12.1 296 126 75ºF IDB: Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 40.3 0.68 22 2.76 12.9 323 141 39.9 0.66 23 2.75 12.9 322 140 36.8 0.64 25 2.68 12.6 312 136 71 40.6 0.52 17 2.74 12.8 319 139 40.2 0.51 18 2.73 12.8 318 139 37.1 0.49 19 2.66 12.5 309 135 35.2 0.95 27 2.75 13.1 333 126 34.9 0.93 28 2.75 13.1 332 125 32.2 0.90 30 2.68 12.8 322 122 36.9 0.86 26 2.84 13.5 352 137 36.5 0.84 27 2.84 13.4 351 137 33.7 0.81 29 2.77 13.1 340 133 39.3 0.69 22 2.94 13.9 367 146 39.0 0.68 23 2.93 13.9 366 146 36.0 0.66 25 2.86 13.5 355 141 33.7 1.00 28 2.84 13.6 353 124 33.4 1.00 29 2.83 13.6 352 124 30.8 0.96 31 2.76 13.2 341 120 Shaded area reflects AHRI conditions 34.5 0.98 28 2.69 12.8 310 118 34.2 0.96 29 2.69 12.8 309 118 31.6 0.93 31 2.62 12.5 299 114 59 33.9 0.94 26 2.67 12.7 306 117 33.6 0.92 27 2.66 12.7 306 117 31.0 0.89 29 2.60 12.4 296 113 34.4 0.98 27 2.90 13.9 379 132 34.0 0.96 28 2.89 13.8 378 132 31.4 0.93 31 2.82 13.5 367 128 38.4 0.72 22 3.10 14.7 418 154 38.0 0.70 23 3.09 14.7 417 153 35.1 0.68 25 3.01 14.3 404 149 71 38.7 0.55 17 3.08 14.6 414 152 38.3 0.54 18 3.07 14.6 413 152 35.3 0.52 19 2.99 14.2 400 147 32.0 1.00 26 2.96 14.3 397 130 31.7 1.00 28 2.95 14.3 395 130 29.3 1.00 31 2.88 14.0 384 126 59 31.5 1.00 26 2.93 14.2 393 129 31.2 0.99 27 2.93 14.2 392 128 28.8 0.95 29 2.85 13.8 380 125 32.6 1.00 27 3.03 14.6 427 138 32.3 1.00 28 3.02 14.6 426 138 29.8 0.96 30 2.94 14.3 413 134 63 32.2 0.94 25 3.00 14.5 423 137 31.8 0.92 26 2.99 14.5 421 137 29.4 0.89 28 2.92 14.1 409 133 34.2 0.92 26 3.13 15.1 451 151 33.8 0.90 27 3.12 15.0 449 151 31.2 0.87 28 3.04 14.7 436 146 67 34.4 0.77 22 3.10 15.0 446 150 34.0 0.75 22 3.10 14.9 445 149 31.4 0.73 24 3.02 14.6 432 145 105ºF 36.5 0.74 22 3.24 15.6 470 161 36.1 0.73 23 3.23 15.5 469 160 33.3 0.70 25 3.15 15.2 455 156 71 36.7 0.57 17 3.21 15.4 465 159 36.4 0.56 18 3.20 15.4 464 159 33.6 0.54 19 3.12 15.0 450 154 29.7 1.00 24 3.07 15.1 438 135 29.4 1.00 26 3.06 15.0 437 134 27.1 1.00 28 2.98 14.7 424 130 59 29.1 1.00 24 3.04 15.0 434 133 28.9 0.99 25 3.03 14.9 433 133 26.6 0.96 27 2.95 14.6 420 129 30.2 1.00 25 3.14 15.4 472 143 29.9 1.00 26 3.13 15.4 470 143 27.6 0.97 28 3.05 15.0 456 138 63 29.8 0.95 23 3.11 15.3 467 142 29.5 0.93 24 3.10 15.2 466 141 27.2 0.90 26 3.02 14.9 452 137 31.7 0.92 24 3.24 15.9 498 156 31.3 0.91 25 3.23 15.8 497 156 28.9 0.87 27 3.15 15.4 482 151 67 31.8 0.77 20 3.22 15.7 493 155 31.5 0.76 21 3.21 15.7 492 154 29.1 0.73 22 3.12 15.3 477 150 115ºF 33.8 0.75 21 3.36 16.4 519 166 33.4 0.74 21 3.35 16.4 518 166 30.9 0.71 23 3.26 15.9 502 161 71 34.0 0.58 16 3.33 16.3 514 165 33.7 0.57 17 3.32 16.2 513 164 31.1 0.55 18 3.23 15.8 497 159 Design Subcooling, 10° F @ liquid access fitting connection AHRI 95 test conditions; Superheat 6° F @ compressor suction access fitting connection. 36.0 0.88 26 3.00 14.3 401 144 35.6 0.87 27 2.99 14.2 399 144 32.9 0.84 29 2.91 13.9 387 139 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 34.7 37.1 39.6 33.1 33.8 36.2 0.88 0.72 0.53 0.97 0.91 0.74 25 22 17 26 25 22 2.73 2.82 2.92 2.81 2.88 2.97 13.0 13.4 13.8 13.5 13.8 14.2 330 348 363 349 376 397 125 136 145 123 131 143 34.3 36.7 39.2 32.8 33.5 35.8 0.86 0.70 0.52 0.95 0.89 0.72 23 26 22 18 27 26 2.72 2.81 2.91 2.81 2.87 2.97 13.0 13.3 13.8 13.4 13.7 14.1 329 347 362 348 375 396 124 136 144 123 130 142 31.7 33.9 36.2 30.3 30.9 33.0 0.83 0.68 0.51 0.92 0.86 0.70 28 24 19 29 28 24 2.65 2.74 2.83 2.73 2.80 2.89 12.7 13.0 13.4 13.1 13.4 13.8 319 337 351 338 363 384 120 131 140 119 126 138 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($0 &217 13 14 www.whirlpoolcomfort.com 40.4 0.85 23 2.60 11.4 228 113 39.2 0.81 24 2.58 11.3 226 112 36.2 0.78 25 2.52 11.1 219 108 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 1050 1200 1350 59 39.7 0.75 20 2.58 11.3 226 112 38.5 0.71 21 2.56 11.2 224 111 35.6 0.69 21 2.50 11.0 217 107 Airflow MBh S/T ΔT 1350 kW Amps Hi PR Lo PR MBh S/T ΔT 1200 kW Amps Hi PR Lo PR MBh S/T ΔT 1050 kW Amps Hi PR Lo PR 41.6 0.76 21 2.65 11.7 245 120 40.3 0.72 22 2.63 11.6 243 119 37.2 0.70 23 2.57 11.3 236 115 63 41.1 0.62 17 2.63 11.6 243 119 39.9 0.59 18 2.61 11.5 241 118 36.9 0.57 18 2.55 11.2 233 114 45.0 0.57 18 2.73 12.0 259 131 43.7 0.55 18 2.71 11.9 257 130 40.3 0.53 19 2.65 11.6 249 126 67 45.1 0.43 13 2.71 11.9 257 130 43.8 0.41 14 2.69 11.8 254 129 40.4 0.40 14 2.63 11.5 246 125 48.3 0.37 12 2.82 12.4 270 140 46.9 0.35 13 2.80 12.3 268 138 43.3 0.34 13 2.73 12.0 260 134 71 39.4 0.88 24 2.79 12.2 256 119 38.3 0.84 25 2.77 12.1 253 118 35.3 0.81 25 2.71 11.8 246 115 59 38.8 0.77 20 2.77 12.1 253 118 37.6 0.74 21 2.75 12.0 251 117 34.7 0.71 22 2.68 11.8 243 113 40.6 0.79 22 2.85 12.5 275 127 39.4 0.75 23 2.83 12.4 273 126 36.4 0.72 23 2.76 12.1 265 122 63 40.2 0.65 18 2.83 12.4 273 126 39.0 0.62 18 2.81 12.3 270 124 36.0 0.59 19 2.74 12.0 262 121 43.9 0.59 18 2.94 12.9 291 139 42.7 0.57 19 2.92 12.8 288 137 39.4 0.55 19 2.85 12.5 279 133 67 44.0 0.45 13 2.92 12.8 288 137 42.7 0.43 14 2.90 12.7 285 136 39.4 0.41 14 2.83 12.4 276 132 75ºF IDB: Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 38.5 0.90 24 2.97 13.2 291 124 37.4 0.86 25 2.94 13.1 288 123 34.5 0.83 25 2.87 12.8 280 119 59 37.8 0.79 20 2.94 13.1 288 123 36.7 0.76 21 2.92 13.0 285 122 33.9 0.73 22 2.85 12.7 277 118 39.6 0.81 22 3.03 13.5 313 132 38.5 0.77 23 3.01 13.4 310 131 35.5 0.74 23 2.93 13.0 301 127 42.9 0.61 18 3.13 13.9 331 144 41.6 0.58 19 3.10 13.8 327 143 38.4 0.56 19 3.03 13.4 318 138 46.0 0.39 12 3.23 14.4 345 153 44.7 0.37 13 3.20 14.2 342 152 41.2 0.36 13 3.12 13.9 331 147 37.5 0.93 24 3.12 14.0 332 130 36.5 0.89 25 3.09 13.9 328 129 33.6 0.85 25 3.02 13.5 318 125 Shaded area reflects ACCA (TVA) conditions 47.2 0.38 12 3.04 13.3 303 148 45.8 0.36 13 3.01 13.2 300 146 42.3 0.35 13 2.94 12.9 291 142 71 38.7 0.83 22 3.19 14.3 357 139 37.5 0.79 23 3.16 14.2 353 137 34.6 0.76 23 3.08 13.8 343 133 44.9 0.40 12 3.40 15.3 393 161 43.6 0.39 13 3.37 15.1 389 160 40.2 0.37 13 3.29 14.8 377 155 71 35.7 0.96 23 3.25 14.8 373 137 34.6 0.92 24 3.22 14.7 369 135 32.0 0.89 25 3.14 14.3 358 131 59 35.1 0.85 20 3.22 14.7 369 135 34.1 0.81 21 3.20 14.6 366 134 31.4 0.78 21 3.12 14.2 355 130 36.7 0.86 22 3.32 15.2 401 145 35.7 0.82 22 3.29 15.0 397 144 32.9 0.79 23 3.21 14.6 385 140 63 36.4 0.71 18 3.29 15.0 397 144 35.3 0.68 18 3.27 14.9 393 142 32.6 0.65 19 3.19 14.5 382 138 39.7 0.65 18 3.43 15.6 424 159 38.6 0.62 18 3.40 15.5 420 157 35.6 0.60 19 3.32 15.1 407 152 67 39.8 0.49 13 3.40 15.5 420 157 38.7 0.47 14 3.37 15.4 415 155 35.7 0.45 14 3.29 15.0 403 151 105ºF 42.7 0.42 12 3.54 16.2 442 169 41.4 0.40 13 3.51 16.0 438 167 38.2 0.39 13 3.43 15.6 425 162 71 33.0 0.97 22 3.36 15.6 412 141 32.1 0.93 23 3.33 15.5 408 140 29.6 0.89 23 3.25 15.1 396 136 59 32.5 0.86 19 3.33 15.5 408 140 31.5 0.82 20 3.31 15.4 404 138 29.1 0.79 20 3.22 15.0 392 134 34.0 0.87 20 3.44 16.0 443 150 33.0 0.83 21 3.41 15.9 439 149 30.5 0.80 21 3.32 15.4 426 144 63 33.7 0.71 16 3.41 15.8 439 149 32.7 0.68 17 3.38 15.7 435 147 30.2 0.66 17 3.29 15.3 422 143 36.8 0.66 17 3.55 16.5 468 164 35.7 0.63 17 3.52 16.3 464 162 33.0 0.61 17 3.43 15.9 450 158 67 36.9 0.50 12 3.52 16.3 464 162 35.8 0.47 13 3.49 16.2 459 161 33.1 0.46 13 3.40 15.8 445 156 115ºF 39.5 0.42 11 3.67 17.1 488 175 38.4 0.40 12 3.64 16.9 484 173 35.4 0.39 12 3.55 16.5 469 168 71 - Design Subcooling, 10° F @ liquid access fitting connection AHRI 95 test conditions; Superheat 6° F @ compressor suction access fitting connection. 41.8 0.63 18 3.29 14.8 377 151 40.6 0.60 19 3.26 14.6 373 150 37.5 0.58 19 3.18 14.3 362 145 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 39.2 43.0 36.9 38.3 41.9 0.66 0.46 0.82 0.68 0.47 18 13 21 18 14 3.01 3.10 3.09 3.16 3.26 13.4 13.8 13.9 14.2 14.6 310 327 328 353 373 131 143 129 137 150 38.1 41.7 35.8 37.1 40.7 0.63 0.44 0.78 0.65 0.45 18 14 21 19 14 2.98 3.08 3.07 3.14 3.24 13.3 13.7 13.8 14.1 14.5 307 324 325 350 369 129 141 128 136 148 35.1 38.5 33.1 34.3 37.6 0.61 0.42 0.75 0.63 0.44 19 14 22 19 14 2.91 3.00 2.99 3.06 3.16 12.9 13.3 13.4 13.7 14.1 298 314 315 339 358 125 137 124 132 144 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($0 WGGE45.00 WGGE45.00 www.whirlpoolcomfort.com 41.8 0.97 28 2.64 11.6 233 115 40.6 0.93 29 2.62 11.5 230 114 37.5 0.90 29 2.56 11.2 223 111 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 1050 1200 1350 59 41.1 0.93 26 2.62 11.5 230 114 39.9 0.89 27 2.60 11.4 228 113 36.8 0.85 28 2.54 11.1 221 110 Airflow MBh S/T ΔT 1350 kW Amps Hi PR Lo PR MBh S/T ΔT 1200 kW Amps Hi PR Lo PR MBh S/T ΔT 1050 kW Amps Hi PR Lo PR 42.6 0.94 27 2.69 11.9 250 123 41.4 0.90 28 2.67 11.8 248 121 38.2 0.86 29 2.61 11.5 240 118 63 42.0 0.87 25 2.67 11.8 248 121 40.8 0.83 26 2.65 11.7 245 120 37.6 0.80 26 2.59 11.4 238 117 44.6 0.85 26 2.78 12.2 264 134 43.3 0.81 27 2.76 12.1 262 133 40.0 0.78 27 2.69 11.8 254 129 67 44.8 0.71 22 2.76 12.1 262 133 43.5 0.68 23 2.73 12.0 259 131 40.2 0.65 23 2.67 11.7 251 127 47.6 0.69 22 2.87 12.6 276 143 46.2 0.66 23 2.84 12.5 273 141 42.7 0.63 24 2.77 12.2 265 137 71 47.9 0.53 17 2.84 12.5 273 141 46.5 0.51 18 2.82 12.4 270 140 43.0 0.49 18 2.75 12.1 262 136 40.8 1.00 28 2.84 12.4 261 122 39.6 0.96 29 2.82 12.3 259 121 36.6 0.93 30 2.75 12.0 251 117 59 40.1 0.96 26 2.82 12.3 259 121 39.0 0.92 27 2.79 12.2 256 119 36.0 0.89 28 2.73 11.9 248 116 41.6 0.97 28 2.90 12.7 281 130 40.4 0.93 29 2.88 12.6 278 128 37.3 0.90 29 2.81 12.3 270 124 63 41.0 0.90 25 2.88 12.6 278 128 39.8 0.86 26 2.85 12.5 275 127 36.7 0.83 27 2.78 12.2 267 123 43.6 0.88 26 2.99 13.1 297 141 42.3 0.84 27 2.97 13.0 294 140 39.1 0.81 28 2.89 12.7 285 136 67 43.8 0.74 22 2.97 13.0 294 140 42.5 0.70 23 2.94 12.9 291 139 39.3 0.68 23 2.87 12.6 282 134 75ºF IDB: Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 46.5 0.71 23 3.09 13.5 309 151 45.1 0.68 24 3.06 13.4 306 149 41.7 0.66 24 2.99 13.1 297 145 71 46.8 0.55 18 3.06 13.4 306 149 45.5 0.52 18 3.04 13.3 303 148 42.0 0.51 19 2.96 13.0 294 143 40.6 1.00 28 3.08 13.7 320 135 39.4 0.95 29 3.06 13.6 316 133 36.4 0.92 29 2.98 13.3 307 129 42.5 0.90 26 3.18 14.1 337 147 41.3 0.86 27 3.15 14.0 334 146 38.1 0.83 28 3.08 13.6 324 141 45.4 0.73 23 3.28 14.6 352 157 44.1 0.70 24 3.26 14.5 348 155 40.7 0.67 24 3.18 14.1 338 150 38.9 1.00 26 3.17 14.2 338 133 37.7 1.00 29 3.15 14.1 335 132 34.8 0.98 30 3.07 13.8 325 128 Shaded area reflects AHRI conditions 39.9 1.00 27 3.02 13.4 297 127 38.7 0.99 29 2.99 13.3 294 125 35.7 0.95 30 2.92 13.0 285 122 59 39.2 1.00 27 2.99 13.3 294 125 38.0 0.94 27 2.97 13.2 291 124 35.1 0.91 28 2.90 12.9 282 120 39.6 1.00 27 3.24 14.6 364 141 38.5 0.98 29 3.21 14.4 360 140 35.5 0.95 29 3.13 14.1 350 136 44.3 0.76 23 3.46 15.5 401 164 43.0 0.72 24 3.43 15.4 397 163 39.7 0.69 24 3.34 15.0 385 158 71 44.6 0.58 18 3.43 15.4 397 163 43.3 0.55 18 3.40 15.3 393 161 40.0 0.53 19 3.31 14.9 381 156 36.9 1.00 25 3.30 15.1 380 139 35.9 1.00 27 3.28 15.0 377 138 33.1 1.00 29 3.20 14.6 365 134 59 36.3 1.00 25 3.28 15.0 377 138 35.2 1.00 27 3.25 14.8 373 137 32.5 0.97 28 3.17 14.5 362 132 37.6 1.00 26 3.38 15.4 409 148 36.6 1.00 28 3.35 15.3 405 147 33.7 0.98 29 3.27 14.9 393 142 63 37.1 1.00 25 3.35 15.3 405 147 36.0 0.95 26 3.32 15.2 401 145 33.2 0.91 27 3.24 14.8 389 141 39.4 0.97 26 3.49 15.9 432 162 38.3 0.92 27 3.46 15.8 428 160 35.3 0.89 27 3.37 15.4 415 155 67 39.6 0.81 22 3.46 15.8 428 160 38.5 0.77 23 3.43 15.6 424 159 35.5 0.74 23 3.34 15.2 411 154 105ºF 42.1 0.78 22 3.60 16.5 451 172 40.8 0.75 23 3.57 16.3 446 171 37.7 0.72 24 3.48 15.9 433 165 71 42.4 0.60 17 3.57 16.3 446 171 41.1 0.58 18 3.54 16.2 442 169 38.0 0.56 18 3.45 15.8 429 164 34.2 1.00 23 3.42 15.9 420 144 33.2 1.00 25 3.39 15.8 416 143 30.7 1.00 27 3.31 15.4 404 138 59 33.6 1.00 23 3.39 15.8 416 143 32.6 1.00 25 3.36 15.6 412 141 30.1 0.98 26 3.28 15.2 400 137 34.9 1.00 24 3.49 16.3 452 153 33.9 1.00 26 3.46 16.1 448 152 31.3 0.99 27 3.38 15.7 434 147 63 34.4 1.00 23 3.46 16.1 448 152 33.4 0.95 24 3.44 16.0 443 150 30.8 0.92 25 3.35 15.6 430 146 36.5 0.97 24 3.61 16.8 478 167 35.5 0.93 25 3.58 16.6 473 166 32.7 0.90 26 3.49 16.2 459 161 67 36.7 0.81 20 3.58 16.6 473 166 35.6 0.78 21 3.55 16.5 468 164 32.9 0.75 22 3.46 16.1 454 159 115ºF 39.0 0.79 21 3.73 17.4 498 178 37.8 0.75 22 3.70 17.2 493 176 34.9 0.73 22 3.61 16.8 479 171 71 39.2 0.61 16 3.70 17.2 493 176 38.1 0.58 17 3.67 17.1 488 175 35.2 0.56 17 3.58 16.6 474 169 Design Subcooling, 10° F @ liquid access fitting connection AHRI 95 test conditions; Superheat 6° F @ compressor suction access fitting connection. 41.5 0.93 26 3.35 15.0 384 154 40.3 0.89 27 3.32 14.9 381 153 37.2 0.86 28 3.24 14.5 369 148 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 40.0 42.8 45.7 38.2 39.0 41.7 0.93 0.75 0.56 1.00 0.96 0.78 25 22 18 26 25 22 3.06 3.15 3.26 3.15 3.21 3.32 13.6 14.0 14.5 14.1 14.4 14.9 316 334 348 335 360 381 133 146 155 132 140 153 38.9 41.5 44.4 37.1 37.9 40.5 0.88 0.72 0.54 0.97 0.91 0.74 23 26 23 18 28 26 3.03 3.13 3.23 3.12 3.19 3.29 13.5 13.9 14.4 14.0 14.3 14.8 313 331 345 332 357 377 132 144 153 130 139 151 35.9 38.3 41.0 34.2 35.0 37.4 0.85 0.69 0.52 0.94 0.88 0.72 27 23 19 28 27 23 2.96 3.05 3.15 3.04 3.11 3.21 13.1 13.5 14.0 13.7 14.0 14.4 304 321 335 322 346 365 128 140 149 126 134 147 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($0 &217 15 16 www.whirlpoolcomfort.com 45.9 0.85 32 2.11 8.7 214 114 45.5 0.84 33 2.11 8.7 213 114 43.2 0.80 34 2.07 8.5 209 111 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 925 1050 1135 59 45.2 0.75 27 2.09 8.6 212 113 44.7 0.73 29 2.09 8.6 211 113 42.5 0.70 30 2.06 8.5 207 110 Airflow MBh S/T ΔT 1135 kW Amps Hi PR Lo PR MBh S/T ΔT 1050 kW Amps Hi PR Lo PR MBh S/T ΔT 925 kW Amps Hi PR Lo PR 47.3 0.76 29 2.15 8.8 230 121 46.8 0.75 31 2.15 8.8 229 121 44.5 0.72 32 2.12 8.7 225 119 63 46.8 0.63 24 2.14 8.8 228 120 46.3 0.61 25 2.13 8.8 227 120 44.0 0.59 26 2.10 8.6 223 117 51.2 0.58 24 2.22 9.1 243 132 50.7 0.57 25 2.21 9.1 242 132 48.1 0.54 26 2.18 8.9 237 129 67 51.3 0.43 18 2.20 9.0 241 131 50.8 0.43 19 2.20 9.0 240 131 48.2 0.41 20 2.16 8.9 235 128 54.9 0.37 17 2.29 9.4 253 141 54.4 0.36 17 2.28 9.4 253 141 51.7 0.35 18 2.25 9.2 248 138 71 44.9 0.88 32 2.27 9.3 240 120 44.4 0.87 34 2.26 9.2 239 120 42.2 0.83 35 2.23 9.1 234 118 59 44.1 0.78 28 2.25 9.2 238 119 43.7 0.76 29 2.24 9.2 237 119 41.5 0.73 30 2.21 9.0 232 116 46.2 0.79 30 2.31 9.5 258 128 45.7 0.77 31 2.31 9.4 257 128 43.4 0.74 32 2.27 9.3 252 125 63 45.7 0.65 24 2.30 9.4 256 127 45.3 0.64 25 2.29 9.4 255 126 43.0 0.61 26 2.25 9.2 250 124 50.0 0.60 24 2.39 9.7 273 140 49.5 0.59 25 2.38 9.7 272 139 47.0 0.56 26 2.34 9.6 266 137 67 50.1 0.45 18 2.37 9.7 270 138 49.6 0.44 19 2.36 9.6 269 138 47.1 0.42 20 2.32 9.5 264 135 75ºF IDB: Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 43.8 0.91 32 2.41 10.0 273 125 43.4 0.89 34 2.40 9.9 272 125 41.2 0.85 35 2.36 9.8 267 122 59 43.1 0.80 28 2.39 9.9 270 124 42.6 0.78 29 2.38 9.9 269 124 40.5 0.75 30 2.34 9.7 264 121 45.1 0.81 30 2.46 10.2 294 133 44.6 0.79 31 2.45 10.1 293 133 42.4 0.76 32 2.41 10.0 287 130 48.8 0.61 24 2.53 10.5 310 145 48.3 0.60 25 2.53 10.4 309 145 45.9 0.58 26 2.49 10.3 303 142 52.4 0.39 17 2.62 10.8 323 155 51.9 0.39 18 2.61 10.8 322 154 49.3 0.37 18 2.57 10.6 316 151 42.7 0.93 32 2.53 10.6 311 131 42.3 0.92 34 2.52 10.5 310 131 40.2 0.88 35 2.48 10.4 304 128 Shaded area reflects ACCA (TVA) conditions 53.7 0.38 17 2.46 10.0 284 149 53.1 0.38 18 2.46 10.0 284 149 50.5 0.36 18 2.42 9.9 278 146 71 44.0 0.84 30 2.58 10.8 334 140 43.6 0.82 31 2.58 10.8 333 139 41.4 0.79 32 2.53 10.6 327 137 51.1 0.41 17 2.75 11.5 368 163 50.6 0.40 18 2.74 11.5 367 162 48.1 0.38 18 2.70 11.3 360 159 71 40.6 0.97 32 2.63 11.2 350 138 40.2 0.95 33 2.63 11.1 349 137 38.2 0.91 35 2.58 10.9 342 135 59 39.9 0.85 28 2.61 11.1 346 136 39.5 0.84 29 2.60 11.0 345 136 37.5 0.80 30 2.56 10.9 338 133 41.8 0.87 29 2.69 11.4 376 147 41.4 0.85 31 2.68 11.4 375 146 39.3 0.81 32 2.64 11.2 368 143 63 41.4 0.71 24 2.67 11.3 372 145 41.0 0.70 25 2.66 11.3 371 145 38.9 0.67 26 2.62 11.1 364 142 45.2 0.66 24 2.78 11.7 397 160 44.8 0.64 25 2.77 11.7 396 160 42.5 0.62 26 2.72 11.5 388 156 67 45.3 0.49 18 2.75 11.6 393 158 44.9 0.48 19 2.75 11.6 392 158 42.6 0.46 20 2.70 11.4 384 155 105ºF 48.5 0.42 17 2.87 12.1 414 170 48.1 0.41 17 2.86 12.1 413 170 45.7 0.40 18 2.81 11.9 405 167 71 37.6 0.98 30 2.72 11.7 386 143 37.2 0.96 31 2.71 11.7 385 142 35.4 0.92 32 2.67 11.5 377 139 59 37.0 0.86 26 2.70 11.6 382 141 36.6 0.84 27 2.69 11.6 381 141 34.8 0.81 28 2.65 11.4 374 138 38.7 0.87 27 2.78 12.0 416 152 38.3 0.86 29 2.77 12.0 415 151 36.4 0.82 30 2.73 11.8 406 148 63 38.3 0.72 22 2.76 11.9 412 150 37.9 0.70 23 2.75 11.9 410 150 36.0 0.67 24 2.71 11.7 402 147 41.9 0.66 22 2.87 12.4 439 166 41.5 0.65 24 2.86 12.3 438 165 39.4 0.62 24 2.82 12.1 429 162 67 42.0 0.50 17 2.85 12.3 435 164 41.6 0.49 18 2.84 12.2 433 163 39.5 0.47 18 2.79 12.0 425 160 115ºF 45.0 0.43 16 2.97 12.8 458 176 44.5 0.42 16 2.96 12.8 457 176 42.3 0.40 17 2.91 12.5 447 172 71 - Design Subcooling, 12° F @ liquid access fitting connection AHRI 95 test conditions; Superheat 12° F @ compressor suction access fitting connection. 47.6 0.63 24 2.66 11.1 353 153 47.1 0.62 26 2.66 11.1 352 152 44.8 0.59 26 2.61 10.9 345 149 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 44.6 48.9 42.0 43.5 47.7 0.67 0.46 0.82 0.69 0.48 24 18 28 24 18 2.44 2.51 2.51 2.56 2.64 10.1 10.4 10.5 10.7 11.0 291 307 308 331 350 132 144 130 138 151 44.2 48.4 41.6 43.1 47.2 0.65 0.45 0.81 0.67 0.47 25 19 29 25 19 2.43 2.51 2.50 2.55 2.64 10.1 10.4 10.4 10.7 11.0 290 306 307 330 349 131 143 130 138 151 42.0 46.0 39.5 41.0 44.9 0.62 0.43 0.77 0.64 0.45 26 20 30 26 20 2.39 2.47 2.46 2.51 2.59 9.9 10.2 10.3 10.5 10.8 284 300 301 324 342 129 141 127 135 148 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($0³6,1*/(67$*( WGGE45.00 WGGE45.00 www.whirlpoolcomfort.com 47.6 0.98 38 2.14 8.8 218 116 47.1 0.96 40 2.14 8.8 218 116 44.7 0.92 41 2.11 8.6 213 114 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 925 1050 1135 59 46.7 0.93 35 2.13 8.7 216 115 46.3 0.92 37 2.12 8.7 215 115 44.0 0.88 38 2.09 8.6 211 113 Airflow MBh S/T ΔT 1135 kW Amps Hi PR Lo PR MBh S/T ΔT 1050 kW Amps Hi PR Lo PR MBh S/T ΔT 925 kW Amps Hi PR Lo PR 48.5 0.95 37 2.19 9.0 235 124 48.0 0.93 39 2.18 9.0 234 123 45.6 0.89 40 2.15 8.8 229 121 63 47.8 0.88 34 2.17 8.9 232 123 47.3 0.86 36 2.17 8.9 232 122 44.9 0.82 37 2.13 8.8 227 120 50.8 0.85 35 2.25 9.2 248 135 50.3 0.84 37 2.25 9.2 247 135 47.8 0.80 38 2.21 9.1 242 132 67 51.0 0.71 29 2.24 9.2 245 134 50.5 0.70 31 2.23 9.1 245 133 48.0 0.67 32 2.20 9.0 240 131 54.2 0.69 30 2.32 9.5 259 144 53.6 0.68 32 2.32 9.5 258 143 51.0 0.65 33 2.28 9.4 253 141 71 54.6 0.53 24 2.31 9.5 256 142 54.0 0.52 25 2.30 9.4 255 142 51.3 0.50 26 2.26 9.3 250 139 46.5 1.00 38 2.30 9.4 245 123 46.0 1.00 40 2.30 9.4 244 123 43.7 0.95 41 2.26 9.2 239 120 59 45.7 0.97 36 2.29 9.3 242 122 45.2 0.95 38 2.28 9.3 242 121 42.9 0.91 39 2.24 9.2 237 119 47.4 0.98 38 2.35 9.6 263 131 46.9 0.96 39 2.35 9.6 263 130 44.5 0.92 41 2.31 9.4 257 128 63 46.7 0.91 34 2.33 9.5 261 129 46.2 0.89 36 2.33 9.5 260 129 43.9 0.85 37 2.29 9.4 255 126 49.6 0.88 36 2.42 9.9 278 143 49.1 0.87 37 2.42 9.9 277 142 46.6 0.83 38 2.38 9.7 272 139 67 49.8 0.74 30 2.41 9.8 275 141 49.4 0.72 31 2.40 9.8 275 141 46.9 0.69 32 2.36 9.6 269 138 75ºF IDB: Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 45.3 1.00 37 2.44 10.1 278 128 44.9 1.00 39 2.44 10.1 278 127 42.7 0.98 41 2.40 9.9 272 125 59 44.6 1.00 36 2.42 10.0 276 126 44.1 0.97 38 2.42 10.0 275 126 41.9 0.93 39 2.38 9.9 269 124 46.2 1.00 37 2.50 10.3 300 136 45.8 0.98 39 2.49 10.3 299 135 43.5 0.94 41 2.45 10.1 293 133 48.4 0.91 36 2.58 10.6 316 148 47.9 0.89 37 2.57 10.6 315 148 45.5 0.85 39 2.53 10.4 309 145 51.6 0.74 31 2.66 11.0 330 158 51.1 0.72 32 2.65 11.0 329 157 48.6 0.69 33 2.61 10.8 322 154 Shaded area reflects AHRI conditions 52.9 0.72 31 2.50 10.2 290 152 52.4 0.70 32 2.50 10.2 289 152 49.8 0.67 33 2.46 10.0 283 149 71 53.3 0.55 24 2.48 10.1 287 150 52.8 0.54 25 2.48 10.1 286 150 50.1 0.52 26 2.44 9.9 281 147 44.2 1.00 36 2.57 10.7 317 134 43.8 1.00 38 2.56 10.7 316 134 41.6 1.00 41 2.52 10.5 310 131 45.1 1.00 37 2.62 11.0 341 143 44.7 1.00 39 2.62 10.9 340 142 42.4 0.97 41 2.58 10.8 333 139 50.4 0.76 31 2.80 11.7 376 166 49.9 0.74 33 2.79 11.6 375 165 47.4 0.71 34 2.74 11.4 367 162 71 50.7 0.58 24 2.77 11.6 372 164 50.2 0.57 25 2.77 11.5 371 164 47.7 0.55 26 2.72 11.4 364 161 42.0 1.00 34 2.67 11.3 357 141 41.6 1.00 36 2.67 11.3 356 140 39.5 1.00 39 2.62 11.1 349 137 59 41.3 1.00 33 2.65 11.3 353 139 40.9 1.00 36 2.65 11.2 352 139 38.9 1.00 39 2.60 11.0 345 136 42.8 1.00 35 2.73 11.6 384 150 42.4 1.00 37 2.73 11.6 383 149 40.3 1.00 40 2.68 11.4 375 146 63 42.2 1.00 34 2.71 11.5 380 148 41.8 0.98 36 2.70 11.5 379 148 39.7 0.94 37 2.66 11.3 371 145 44.9 0.97 35 2.82 11.9 405 163 44.4 0.95 37 2.81 11.9 404 163 42.2 0.91 38 2.77 11.7 396 160 67 45.1 0.81 30 2.80 11.8 401 162 44.7 0.80 31 2.79 11.8 400 161 42.4 0.76 32 2.75 11.6 392 158 105ºF 47.9 0.79 31 2.91 12.3 423 174 47.4 0.77 32 2.91 12.3 422 173 45.0 0.74 33 2.86 12.1 413 170 71 48.2 0.61 24 2.89 12.2 419 172 47.7 0.60 25 2.88 12.2 417 172 45.3 0.57 26 2.84 12.0 409 168 38.9 1.00 32 2.77 11.9 394 145 38.5 1.00 34 2.76 11.9 393 145 36.6 1.00 36 2.71 11.7 385 142 59 38.3 1.00 31 2.74 11.8 390 144 37.9 1.00 33 2.74 11.8 389 144 36.0 1.01 36 2.69 11.6 381 141 39.7 1.00 32 2.83 12.2 424 155 39.3 1.00 34 2.82 12.2 423 154 37.3 1.00 37 2.77 12.0 414 151 63 39.1 1.00 32 2.80 12.1 420 153 38.7 0.99 33 2.80 12.1 419 153 36.8 0.94 35 2.75 11.9 410 150 41.6 0.98 33 2.92 12.6 448 169 41.2 0.96 35 2.91 12.5 447 168 39.1 0.92 36 2.86 12.3 438 165 67 41.8 0.82 28 2.90 12.5 443 167 41.4 0.80 29 2.89 12.4 442 167 39.3 0.77 30 2.84 12.2 433 163 115ºF 44.3 0.79 29 3.02 13.0 467 180 43.9 0.78 30 3.01 13.0 466 179 41.7 0.75 31 2.96 12.8 456 176 71 44.7 0.61 22 2.99 12.9 463 178 44.2 0.60 23 2.98 12.9 461 178 42.0 0.57 24 2.93 12.7 452 174 Design Subcooling, 12° F @ liquid access fitting connection AHRI 95 test conditions; Superheat 12° F @ compressor suction access fitting connection. 47.2 0.94 36 2.71 11.3 360 156 46.8 0.92 38 2.70 11.3 359 155 44.4 0.88 39 2.66 11.1 352 152 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 45.5 48.7 52.0 43.5 44.4 47.5 0.93 0.76 0.57 1.00 0.96 0.78 34 30 24 35 35 30 2.48 2.55 2.64 2.55 2.60 2.69 10.3 10.6 10.9 10.6 10.9 11.2 297 313 327 314 338 357 135 147 156 133 141 154 45.1 48.2 51.5 43.1 44.0 47.0 0.91 0.74 0.56 1.00 0.94 0.77 32 36 31 25 38 36 2.47 2.55 2.63 2.54 2.60 2.68 10.2 10.5 10.9 10.6 10.8 11.2 296 312 326 313 337 356 134 146 156 132 141 154 42.8 45.8 48.9 40.9 41.8 44.7 0.87 0.71 0.53 0.96 0.90 0.73 37 32 26 39 37 33 2.43 2.51 2.59 2.50 2.55 2.64 10.1 10.4 10.7 10.4 10.7 11.0 290 306 319 307 330 349 131 143 153 130 138 151 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($0³6,1*/(67$*( &217 17 18 www.whirlpoolcomfort.com 46.8 0.82 24 3.14 13.0 232 109 45.5 0.79 25 3.11 12.9 230 108 42.0 0.76 26 3.04 12.5 223 105 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 1125 1300 1475 59 46.1 0.72 21 3.11 12.9 230 108 44.7 0.69 22 3.09 12.8 227 107 41.3 0.67 22 3.01 12.4 221 104 Airflow MBh S/T ΔT 1475 kW Amps Hi PR Lo PR MBh S/T ΔT 1300 kW Amps Hi PR Lo PR MBh S/T ΔT 1125 kW Amps Hi PR Lo PR 48.2 0.74 22 3.20 13.2 250 116 46.8 0.70 23 3.18 13.1 247 115 43.2 0.68 24 3.10 12.8 240 111 63 47.7 0.60 18 3.18 13.1 247 115 46.3 0.58 19 3.15 13.0 245 114 42.8 0.56 19 3.08 12.7 237 110 52.2 0.56 18 3.30 13.6 264 127 50.7 0.53 19 3.28 13.5 261 125 46.8 0.51 20 3.20 13.2 253 122 67 52.3 0.42 14 3.28 13.5 261 125 50.8 0.40 14 3.25 13.4 258 124 46.9 0.39 15 3.17 13.1 251 120 56.0 0.36 13 3.41 14.1 275 135 54.4 0.34 13 3.38 14.0 272 134 50.2 0.33 14 3.30 13.6 264 130 71 45.7 0.85 24 3.38 13.9 260 115 44.4 0.81 26 3.35 13.8 258 114 41.0 0.78 26 3.27 13.4 250 111 59 45.0 0.75 21 3.35 13.8 258 114 43.7 0.72 22 3.32 13.7 255 113 40.3 0.69 23 3.24 13.3 247 109 47.1 0.76 22 3.45 14.2 280 123 45.7 0.73 24 3.42 14.1 277 121 42.2 0.70 24 3.34 13.7 269 118 63 46.6 0.63 18 3.42 14.1 277 121 45.3 0.60 19 3.39 14.0 275 120 41.8 0.58 20 3.31 13.6 266 116 51.0 0.58 18 3.56 14.6 296 134 49.5 0.55 19 3.53 14.5 293 132 45.7 0.53 20 3.45 14.1 284 128 67 51.1 0.43 14 3.53 14.5 293 132 49.6 0.41 15 3.50 14.4 290 131 45.8 0.40 15 3.42 14.0 281 127 75ºF IDB: Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 44.7 0.87 24 3.59 15.0 296 120 43.4 0.83 26 3.56 14.8 293 119 40.0 0.80 26 3.47 14.5 284 115 59 43.9 0.77 21 3.56 14.8 293 118 42.6 0.73 22 3.53 14.7 290 117 39.4 0.71 23 3.45 14.4 281 114 46.0 0.78 22 3.67 15.3 319 127 44.6 0.75 24 3.64 15.2 315 126 41.2 0.72 24 3.55 14.8 306 122 49.8 0.59 18 3.79 15.8 336 139 48.3 0.56 19 3.76 15.6 333 138 44.6 0.54 20 3.66 15.2 323 134 53.4 0.38 13 3.92 16.3 351 148 51.9 0.36 13 3.88 16.2 347 147 47.9 0.35 14 3.79 15.8 337 142 43.6 0.90 25 3.78 15.9 337 126 42.3 0.86 26 3.75 15.8 334 124 39.0 0.83 26 3.66 15.4 324 121 Shaded area reflects ACCA (TVA) conditions 54.7 0.37 13 3.68 15.1 308 142 53.1 0.35 13 3.65 15.0 305 141 49.0 0.34 14 3.56 14.6 296 137 71 44.9 0.81 23 3.86 16.2 363 134 43.6 0.77 24 3.83 16.1 359 132 40.2 0.74 24 3.74 15.7 348 128 52.1 0.39 13 4.12 17.3 400 156 50.6 0.38 13 4.09 17.2 396 154 46.7 0.36 14 3.99 16.7 384 149 71 41.4 0.94 24 3.94 16.8 379 132 40.2 0.89 25 3.91 16.7 376 130 37.1 0.86 26 3.81 16.3 364 127 59 40.7 0.82 21 3.91 16.7 375 130 39.5 0.79 22 3.87 16.5 372 129 36.5 0.76 23 3.78 16.1 361 125 42.6 0.84 22 4.03 17.2 408 140 41.4 0.80 23 3.99 17.1 404 139 38.2 0.77 24 3.89 16.6 392 135 63 42.2 0.69 18 3.99 17.1 404 139 41.0 0.66 19 3.96 16.9 400 137 37.8 0.63 20 3.86 16.5 388 133 46.1 0.63 18 4.16 17.7 431 153 44.8 0.61 19 4.13 17.6 427 152 41.3 0.58 20 4.02 17.1 414 147 67 46.2 0.48 14 4.13 17.6 427 151 44.9 0.45 14 4.09 17.4 422 150 41.4 0.44 15 3.99 17.0 410 145 105ºF 49.5 0.41 13 4.30 18.4 450 163 48.1 0.39 13 4.27 18.2 445 161 44.4 0.38 14 4.16 17.7 432 157 71 38.3 0.95 23 4.08 17.7 419 136 37.2 0.90 24 4.04 17.6 415 135 34.4 0.87 24 3.94 17.1 402 131 59 37.7 0.83 20 4.04 17.6 415 135 36.6 0.79 21 4.01 17.4 411 134 33.8 0.76 21 3.91 17.0 398 130 39.5 0.85 21 4.17 18.1 451 145 38.3 0.81 22 4.13 18.0 447 144 35.4 0.78 22 4.03 17.5 433 139 63 39.1 0.69 17 4.13 18.0 446 144 37.9 0.66 18 4.10 17.8 442 142 35.0 0.64 18 4.00 17.4 429 138 42.7 0.64 17 4.31 18.7 476 158 41.5 0.61 18 4.27 18.5 471 157 38.3 0.59 18 4.16 18.1 457 152 67 42.8 0.48 13 4.27 18.5 471 157 41.6 0.46 13 4.24 18.4 467 155 38.4 0.44 14 4.13 17.9 453 150 115ºF 45.9 0.41 12 4.46 19.4 497 169 44.5 0.39 12 4.42 19.2 492 167 41.1 0.38 13 4.30 18.7 477 162 71 - Design Subcooling, 12° F @ liquid access fitting connection AHRI 95 test conditions; Superheat 12° F @ compressor suction access fitting connection. 48.6 0.61 19 3.99 16.7 383 146 47.1 0.58 19 3.96 16.6 379 145 43.5 0.56 20 3.86 16.2 368 140 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 45.5 49.9 42.8 44.4 48.7 0.64 0.45 0.79 0.66 0.46 18 14 21 18 14 3.64 3.76 3.75 3.83 3.96 15.2 15.6 15.8 16.1 16.6 315 333 334 359 379 126 138 124 132 145 44.2 48.4 41.6 43.1 47.2 0.61 0.42 0.76 0.63 0.44 19 15 22 19 15 3.61 3.73 3.72 3.80 3.92 15.0 15.5 15.6 16.0 16.5 312 330 330 356 375 125 136 123 131 143 40.8 44.7 38.4 39.8 43.6 0.59 0.41 0.73 0.61 0.42 20 15 23 20 15 3.52 3.63 3.62 3.70 3.83 14.7 15.1 15.2 15.6 16.0 303 320 321 345 364 121 132 120 127 139 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($0³7:267$*( WGGE45.00 WGGE45.00 www.whirlpoolcomfort.com 48.5 0.95 29 3.19 13.2 237 111 47.1 0.90 30 3.16 13.1 234 110 43.5 0.87 31 3.09 12.7 227 107 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 1125 1300 1475 59 47.7 0.90 27 3.16 13.1 234 110 46.3 0.86 28 3.14 13.0 232 109 42.7 0.83 29 3.06 12.6 225 106 Airflow MBh S/T ΔT 1475 kW Amps Hi PR Lo PR MBh S/T ΔT 1300 kW Amps Hi PR Lo PR MBh S/T ΔT 1125 kW Amps Hi PR Lo PR 49.4 0.91 28 3.25 13.4 255 118 48.0 0.87 30 3.23 13.3 252 117 44.3 0.84 30 3.15 13.0 245 114 63 48.7 0.85 26 3.23 13.3 252 117 47.3 0.81 27 3.20 13.2 250 116 43.6 0.78 28 3.13 12.9 242 113 51.8 0.82 27 3.36 13.8 269 129 50.3 0.79 28 3.33 13.7 266 128 46.4 0.76 29 3.25 13.4 258 124 67 52.0 0.69 22 3.33 13.7 266 128 50.5 0.66 23 3.30 13.6 264 127 46.6 0.63 24 3.22 13.3 256 123 55.2 0.67 23 3.47 14.3 280 138 53.6 0.64 24 3.44 14.2 278 136 49.5 0.61 25 3.35 13.8 269 132 71 55.6 0.52 18 3.44 14.2 278 136 54.0 0.49 19 3.41 14.1 275 135 49.9 0.47 19 3.33 13.7 267 131 47.4 0.98 29 3.43 14.1 266 118 46.0 0.94 30 3.41 14.0 263 116 42.5 0.90 31 3.32 13.7 255 113 59 46.6 0.94 27 3.41 14.0 263 116 45.2 0.89 29 3.38 13.9 260 115 41.7 0.86 29 3.30 13.6 252 112 48.3 0.95 28 3.51 14.4 286 125 46.9 0.90 30 3.48 14.3 283 124 43.3 0.87 31 3.39 14.0 274 120 63 47.6 0.88 26 3.48 14.3 283 124 46.2 0.84 27 3.45 14.2 280 123 42.6 0.81 28 3.37 13.8 272 119 50.6 0.85 27 3.62 14.9 302 136 49.1 0.81 28 3.59 14.7 299 135 45.3 0.79 29 3.50 14.4 290 131 67 50.8 0.71 23 3.59 14.7 299 135 49.4 0.68 24 3.56 14.6 296 134 45.6 0.66 24 3.47 14.2 287 130 75ºF IDB: Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 46.2 1.00 29 3.65 15.2 302 122 44.9 0.96 30 3.62 15.1 299 121 41.4 0.93 31 3.53 14.7 290 117 59 45.5 0.96 27 3.62 15.1 299 121 44.1 0.92 29 3.59 15.0 296 120 40.7 0.88 29 3.50 14.6 287 116 47.1 0.97 29 3.73 15.6 325 130 45.8 0.93 30 3.70 15.4 322 129 42.2 0.89 31 3.61 15.0 312 125 49.4 0.88 27 3.85 16.0 343 142 47.9 0.84 28 3.82 15.9 340 140 44.2 0.81 29 3.73 15.5 330 136 52.7 0.71 23 3.98 16.6 358 151 51.1 0.68 25 3.95 16.4 354 150 47.2 0.65 25 3.85 16.0 344 145 Shaded area reflects AHRI conditions 54.0 0.69 23 3.74 15.4 315 145 52.4 0.66 24 3.71 15.2 312 144 48.4 0.64 25 3.62 14.8 302 140 71 54.3 0.53 18 3.71 15.2 312 144 52.8 0.51 19 3.68 15.1 309 142 48.7 0.49 20 3.59 14.7 299 138 45.1 1.00 28 3.84 16.2 344 128 43.8 0.99 31 3.81 16.0 341 127 40.4 0.95 32 3.72 15.6 330 123 46.0 1.00 29 3.93 16.5 370 136 44.7 0.96 30 3.90 16.4 366 135 41.2 0.92 31 3.80 16.0 355 131 51.4 0.73 23 4.20 17.6 408 159 49.9 0.70 25 4.16 17.5 404 157 46.0 0.67 25 4.05 17.0 392 152 71 51.8 0.57 18 4.16 17.5 404 157 50.2 0.54 19 4.13 17.3 400 156 46.4 0.52 20 4.02 16.9 388 151 42.9 1.00 27 4.01 17.1 387 134 41.6 1.00 29 3.97 17.0 383 133 38.4 0.99 31 3.87 16.5 372 129 59 42.1 1.00 26 3.97 17.0 383 133 40.9 0.98 28 3.94 16.8 379 132 37.8 0.95 29 3.84 16.4 368 128 43.7 1.00 27 4.10 17.5 416 143 42.4 0.99 30 4.06 17.4 412 142 39.2 0.96 31 3.96 16.9 400 137 63 43.0 0.96 26 4.06 17.4 412 142 41.8 0.92 27 4.03 17.2 408 140 38.6 0.89 28 3.93 16.8 396 136 45.8 0.94 27 4.23 18.0 440 156 44.4 0.90 28 4.20 17.9 435 155 41.0 0.86 29 4.09 17.4 422 150 67 46.0 0.78 22 4.20 17.9 435 155 44.7 0.75 24 4.16 17.7 431 153 41.2 0.72 24 4.06 17.3 418 148 105ºF 48.8 0.76 23 4.38 18.7 459 166 47.4 0.73 24 4.34 18.5 454 165 43.7 0.70 25 4.23 18.0 440 160 71 49.2 0.59 18 4.34 18.5 454 165 47.7 0.56 19 4.30 18.4 450 163 44.1 0.54 19 4.19 17.9 436 158 39.7 1.00 25 4.15 18.0 428 139 38.5 1.00 27 4.11 17.9 423 138 35.6 1.00 29 4.01 17.4 411 134 59 39.0 1.00 24 4.11 17.9 423 138 37.9 0.99 26 4.08 17.7 419 136 35.0 0.95 27 3.98 17.3 407 132 40.5 1.00 25 4.24 18.5 460 148 39.3 1.00 28 4.21 18.3 456 146 36.3 0.96 29 4.10 17.8 442 142 63 39.9 1.00 25 4.21 18.3 456 146 38.7 0.93 25 4.17 18.1 451 145 35.7 0.89 26 4.06 17.7 437 141 42.4 0.95 25 4.38 19.0 486 162 41.2 0.90 26 4.35 18.9 481 160 38.0 0.87 27 4.23 18.4 467 155 67 42.6 0.79 21 4.35 18.9 481 160 41.4 0.75 22 4.31 18.7 476 158 38.2 0.73 23 4.20 18.2 462 154 115ºF 45.2 0.77 22 4.53 19.7 507 172 43.9 0.73 23 4.49 19.5 502 170 40.5 0.71 23 4.38 19.0 487 165 71 45.5 0.59 17 4.49 19.5 502 170 44.2 0.56 18 4.46 19.4 497 169 40.8 0.54 18 4.34 18.9 482 164 Design Subcooling, 12° F @ liquid access fitting connection AHRI 95 test conditions; Superheat 12° F @ compressor suction access fitting connection. 48.2 0.90 27 4.06 17.0 391 149 46.8 0.86 29 4.02 16.9 387 148 43.2 0.83 29 3.92 16.5 375 143 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 46.4 49.6 53.0 44.3 45.3 48.4 0.90 0.73 0.55 1.00 0.93 0.76 26 23 18 28 26 23 3.70 3.82 3.95 3.81 3.90 4.02 15.4 15.9 16.4 16.0 16.4 16.9 322 340 354 341 366 387 129 140 150 127 135 148 45.1 48.2 51.5 43.1 44.0 47.0 0.86 0.70 0.52 0.94 0.89 0.72 24 27 24 19 29 28 3.67 3.79 3.92 3.78 3.86 3.99 15.3 15.8 16.3 15.9 16.3 16.7 319 336 351 337 363 383 127 139 148 126 134 146 41.6 44.5 47.5 39.7 40.6 43.4 0.83 0.67 0.50 0.91 0.85 0.70 28 24 20 30 28 25 3.58 3.70 3.82 3.69 3.77 3.89 14.9 15.4 15.9 15.5 15.8 16.3 309 326 340 327 352 372 124 135 144 122 130 142 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($0³7:267$*( &217 19 20 www.whirlpoolcomfort.com 40.9 0.88 23 2.90 13.7 233 112 39.7 0.84 24 2.88 13.6 231 111 36.6 0.81 24 2.81 13.3 224 108 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 1138 1300 1463 59 40.2 0.77 20 2.88 13.6 231 111 39.0 0.74 20 2.86 13.5 228 110 36.0 0.71 21 2.79 13.2 222 106 Airflow MBh S/T ΔT 1463 kW Amps Hi PR Lo PR MBh S/T ΔT 1300 kW Amps Hi PR Lo PR MBh S/T ΔT 1138 kW Amps Hi PR Lo PR 42.1 0.79 21 2.96 14.0 251 119 40.8 0.75 22 2.94 13.9 248 118 37.7 0.72 22 2.87 13.6 241 114 63 41.6 0.65 17 2.94 13.9 248 118 40.4 0.62 18 2.92 13.8 246 117 37.3 0.59 18 2.85 13.5 238 113 45.5 0.60 17 3.05 14.3 265 130 44.2 0.57 18 3.03 14.2 262 129 40.8 0.55 18 2.96 13.9 254 125 67 45.6 0.45 13 3.03 14.2 262 129 44.3 0.43 13 3.00 14.1 260 127 40.9 0.41 14 2.93 13.8 252 124 48.9 0.38 12 3.15 14.7 276 138 47.4 0.37 12 3.12 14.6 274 137 43.8 0.35 12 3.05 14.3 265 133 71 39.9 0.91 23 3.12 14.6 262 118 38.7 0.87 24 3.09 14.5 259 117 35.8 0.84 24 3.02 14.2 251 114 59 39.2 0.80 20 3.09 14.5 259 117 38.1 0.76 21 3.07 14.4 256 116 35.2 0.74 21 3.00 14.1 249 112 41.1 0.81 21 3.18 14.8 281 126 39.9 0.78 22 3.16 14.7 279 125 36.8 0.75 22 3.08 14.4 270 121 63 40.7 0.67 17 3.16 14.7 279 125 39.5 0.64 18 3.13 14.6 276 123 36.4 0.62 18 3.06 14.3 268 120 44.5 0.62 17 3.28 15.2 297 137 43.2 0.59 18 3.25 15.1 294 136 39.9 0.57 18 3.18 14.8 285 132 67 44.6 0.46 13 3.25 15.1 294 136 43.3 0.44 14 3.23 15.0 291 135 39.9 0.43 14 3.15 14.7 283 131 75ºF 71 47.7 0.40 12 3.38 15.7 310 146 46.3 0.38 12 3.36 15.6 307 145 42.8 0.36 13 3.28 15.2 298 141 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 39.0 0.93 23 3.31 15.6 297 123 37.8 0.89 24 3.28 15.4 294 122 34.9 0.86 24 3.20 15.1 286 118 59 38.3 0.82 20 3.28 15.4 294 122 37.2 0.78 21 3.25 15.3 292 120 34.3 0.76 21 3.18 15.0 283 117 40.1 0.84 21 3.38 15.9 320 131 38.9 0.80 22 3.35 15.7 317 129 35.9 0.77 22 3.27 15.4 307 126 46.6 0.41 12 3.59 16.8 353 152 45.2 0.39 12 3.57 16.6 349 151 41.8 0.37 13 3.48 16.3 339 146 38.0 0.96 23 3.47 16.4 339 129 36.9 0.92 24 3.45 16.3 335 128 34.1 0.89 24 3.36 15.9 325 124 39.1 0.86 21 3.55 16.7 365 137 38.0 0.82 22 3.52 16.6 361 136 35.1 0.79 22 3.43 16.2 350 132 42.4 0.65 17 3.66 17.2 385 150 41.1 0.62 18 3.63 17.1 381 149 38.0 0.60 18 3.54 16.7 370 144 45.5 0.42 12 3.78 17.7 402 160 44.1 0.40 13 3.75 17.6 398 158 40.7 0.39 13 3.66 17.2 386 153 71 - Shaded area reflects ACCA (TVA) conditions. 43.4 0.63 17 3.48 16.3 338 143 42.2 0.60 18 3.45 16.2 335 141 38.9 0.58 18 3.37 15.8 325 137 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 39.7 43.5 37.4 38.7 42.4 0.69 0.48 0.85 0.71 0.49 17 13 20 17 13 3.35 3.45 3.44 3.52 3.63 15.7 16.2 16.3 16.6 17.1 317 335 335 361 381 129 141 128 136 148 38.5 42.2 36.3 37.6 41.2 0.65 0.45 0.81 0.68 0.47 18 14 21 18 14 3.32 3.43 3.42 3.49 3.60 15.6 16.0 16.2 16.5 16.9 314 331 332 357 377 128 140 127 135 147 35.6 39.0 33.5 34.7 38.0 0.63 0.44 0.78 0.65 0.45 18 14 21 18 14 3.24 3.34 3.34 3.41 3.51 15.3 15.7 15.8 16.1 16.5 304 321 322 347 366 124 136 123 131 143 36.1 1.00 23 3.62 17.3 381 135 35.1 0.95 24 3.59 17.1 377 134 32.4 0.92 24 3.50 16.7 366 130 59 35.5 0.88 20 3.59 17.1 377 134 34.5 0.84 20 3.56 17.0 374 133 31.8 0.81 21 3.47 16.6 362 129 37.2 0.90 21 3.69 17.6 410 144 36.1 0.85 22 3.66 17.5 406 143 33.3 0.82 22 3.57 17.1 394 138 63 36.8 0.74 17 3.66 17.5 406 143 35.7 0.70 18 3.63 17.3 402 141 33.0 0.68 18 3.55 17.0 390 137 43.2 0.44 12 3.94 18.7 452 167 41.9 0.42 12 3.91 18.5 447 166 38.7 0.40 13 3.81 18.1 434 161 71 33.4 1.00 21 3.74 18.1 421 140 32.5 0.96 22 3.71 18.0 417 139 30.0 0.93 22 3.62 17.6 404 134 59 32.9 0.89 18 3.71 18.0 417 139 31.9 0.85 19 3.68 17.8 413 137 29.5 0.82 19 3.59 17.4 400 133 34.4 0.90 20 3.82 18.5 453 149 33.4 0.86 20 3.79 18.3 449 147 30.9 0.83 21 3.70 17.9 435 143 63 34.1 0.74 16 3.79 18.3 449 147 33.1 0.71 17 3.76 18.2 444 146 30.5 0.68 17 3.67 17.8 431 142 37.3 0.68 16 3.94 19.0 479 163 36.2 0.65 17 3.91 18.8 474 161 33.4 0.63 17 3.81 18.4 460 156 67 37.3 0.51 12 3.91 18.8 474 161 36.3 0.49 13 3.88 18.7 469 159 33.5 0.47 13 3.78 18.3 455 155 115ºF 40.0 0.44 11 4.07 19.6 499 173 38.8 0.42 12 4.04 19.4 494 171 35.8 0.40 12 3.94 19.0 479 166 71 - Amps = outdoor unit amps (comp.+fan) kW = Total system power 40.2 0.68 17 3.81 18.1 433 157 39.1 0.65 18 3.78 18.0 429 156 36.1 0.62 18 3.69 17.5 416 151 67 40.3 0.51 13 3.78 18.0 429 156 39.1 0.49 13 3.75 17.8 424 154 36.1 0.47 14 3.66 17.4 412 149 105ºF 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($ 0³6,1*/(67$*( WGGE45.00 WGGE45.00 www.whirlpoolcomfort.com 42.3 1.00 27 2.95 13.9 238 114 41.1 0.96 28 2.92 13.8 235 113 37.9 0.93 28 2.86 13.5 228 110 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 1138 1300 1463 59 41.6 0.96 25 2.92 13.8 235 113 40.4 0.92 26 2.90 13.7 233 112 37.3 0.89 27 2.84 13.4 226 109 Airflow MBh S/T ΔT 1463 kW Amps Hi PR Lo PR MBh S/T ΔT 1300 kW Amps Hi PR Lo PR MBh S/T ΔT 1138 kW Amps Hi PR Lo PR 43.1 0.98 26 3.01 14.2 256 122 41.9 0.93 28 2.98 14.1 253 120 38.6 0.90 28 2.91 13.8 246 117 63 42.5 0.90 24 2.98 14.1 253 120 41.3 0.86 25 2.96 14.0 251 119 38.1 0.83 26 2.89 13.7 243 116 45.2 0.88 25 3.10 14.5 270 133 43.9 0.84 26 3.07 14.4 268 131 40.5 0.81 26 3.00 14.1 260 127 67 45.4 0.74 21 3.07 14.4 268 131 44.1 0.70 22 3.05 14.3 265 130 40.7 0.68 22 2.98 14.0 257 126 48.2 0.71 22 3.19 14.9 282 141 46.8 0.68 23 3.17 14.8 279 140 43.2 0.66 23 3.10 14.5 271 136 71 48.5 0.55 17 3.17 14.8 279 140 47.1 0.52 17 3.15 14.7 276 139 43.5 0.51 18 3.07 14.4 268 134 41.3 1.00 26 3.17 14.8 267 121 40.1 1.00 28 3.14 14.7 264 119 37.0 0.96 29 3.07 14.4 256 116 59 40.6 1.00 26 3.14 14.7 264 119 39.4 0.95 27 3.12 14.6 262 118 36.4 0.92 27 3.04 14.3 254 115 42.1 1.00 26 3.23 15.1 287 128 40.9 0.96 28 3.21 14.9 284 127 37.7 0.93 28 3.13 14.6 276 123 63 41.5 0.94 24 3.21 14.9 284 127 40.3 0.89 25 3.18 14.8 281 126 37.2 0.86 26 3.11 14.5 273 122 44.1 0.91 25 3.33 15.4 303 140 42.8 0.87 26 3.31 15.3 300 139 39.5 0.84 27 3.23 15.0 291 135 67 44.3 0.76 21 3.31 15.3 300 139 43.1 0.73 22 3.28 15.2 297 137 39.7 0.70 23 3.20 14.9 288 133 75ºF 47.1 0.74 22 3.44 15.9 316 149 45.7 0.71 23 3.41 15.8 313 148 42.2 0.68 23 3.33 15.4 304 143 71 47.4 0.57 17 3.41 15.8 313 148 46.0 0.54 18 3.38 15.7 310 146 42.5 0.52 18 3.30 15.3 301 142 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 40.3 1.00 25 3.36 15.8 303 125 39.2 1.00 28 3.33 15.7 300 124 36.2 0.99 29 3.25 15.3 291 120 59 39.6 1.00 25 3.33 15.7 300 124 38.5 0.98 27 3.31 15.6 297 123 35.5 0.94 27 3.23 15.2 289 119 41.1 1.00 26 3.43 16.1 327 133 39.9 0.99 28 3.40 16.0 323 132 36.9 0.95 28 3.32 15.6 314 128 43.1 0.94 25 3.54 16.5 345 146 41.8 0.89 26 3.51 16.4 341 144 38.6 0.86 27 3.43 16.0 331 140 39.4 1.00 25 3.53 16.7 346 132 38.2 1.00 27 3.50 16.5 342 130 35.3 1.00 29 3.42 16.2 332 127 40.1 1.00 25 3.61 17.0 372 140 39.0 1.00 28 3.58 16.9 368 139 36.0 0.98 29 3.49 16.5 357 135 42.0 0.97 26 3.72 17.5 393 153 40.8 0.92 27 3.69 17.3 389 152 37.7 0.89 27 3.60 16.9 377 147 44.8 0.78 22 3.84 18.0 410 163 43.5 0.75 23 3.81 17.9 406 161 40.2 0.72 23 3.72 17.4 393 157 71 45.1 0.60 17 3.81 17.9 406 161 43.8 0.58 18 3.78 17.7 402 160 40.5 0.55 18 3.69 17.3 390 155 Shaded area reflects AHRI conditions 45.9 0.76 22 3.65 17.0 360 155 44.6 0.72 23 3.62 16.9 356 154 41.2 0.70 23 3.54 16.5 345 149 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 40.5 43.3 46.3 38.7 39.5 42.2 0.96 0.78 0.58 1.00 1.00 0.81 24 21 17 24 25 21 3.40 3.51 3.62 3.50 3.58 3.69 16.0 16.4 16.9 16.5 16.9 17.3 323 341 356 342 368 389 132 144 154 130 139 152 39.3 42.0 44.9 37.6 38.4 41.0 0.92 0.75 0.56 1.00 0.95 0.77 22 25 22 18 27 26 3.38 3.48 3.59 3.47 3.55 3.66 15.9 16.3 16.8 16.4 16.7 17.2 320 338 353 339 365 385 131 143 152 129 137 150 36.3 38.8 41.5 34.7 35.4 37.8 0.88 0.72 0.54 0.97 0.91 0.74 26 23 18 27 26 23 3.30 3.40 3.51 3.39 3.46 3.57 15.5 15.9 16.4 16.0 16.4 16.8 311 328 342 329 354 373 127 139 148 125 133 146 37.4 1.00 24 3.67 17.5 389 138 36.3 1.00 26 3.65 17.4 385 137 33.5 1.00 27 3.56 17.0 373 133 59 36.7 1.00 23 3.65 17.4 385 137 35.7 1.00 25 3.62 17.3 381 135 32.9 1.01 27 3.53 16.9 370 131 38.1 1.00 24 3.75 17.9 418 147 37.0 1.00 26 3.72 17.7 414 145 34.2 1.00 28 3.63 17.3 402 141 63 37.6 1.00 24 3.72 17.7 414 145 36.5 0.98 25 3.69 17.6 410 144 33.6 0.95 26 3.60 17.2 398 140 42.6 0.81 22 4.00 19.0 461 171 41.3 0.78 23 3.97 18.8 456 169 38.2 0.75 23 3.87 18.4 443 164 71 42.9 0.63 17 3.97 18.8 456 169 41.6 0.60 18 3.94 18.7 452 167 38.4 0.58 18 3.84 18.2 438 162 34.6 1.00 22 3.80 18.4 430 143 33.6 1.00 24 3.77 18.2 425 141 31.0 1.00 25 3.68 17.8 413 137 59 34.0 1.00 21 3.77 18.2 425 141 33.0 1.00 23 3.74 18.1 421 140 30.5 1.02 25 3.65 17.7 408 136 35.3 1.00 22 3.88 18.8 462 152 34.3 1.00 24 3.85 18.6 458 150 31.6 1.00 26 3.76 18.2 444 146 63 34.8 1.00 22 3.85 18.6 458 150 33.8 0.99 24 3.82 18.5 453 149 31.2 0.95 24 3.73 18.1 440 144 37.0 1.00 23 4.01 19.3 488 166 35.9 0.96 24 3.98 19.1 483 164 33.1 0.93 25 3.88 18.7 469 159 67 37.2 0.84 20 3.98 19.1 483 164 36.1 0.81 21 3.94 19.0 479 163 33.3 0.78 21 3.85 18.6 464 158 115ºF 39.4 0.82 20 4.14 19.9 509 177 38.3 0.78 21 4.11 19.8 504 175 35.4 0.75 22 4.01 19.3 489 170 71 39.7 0.63 16 4.11 19.8 504 175 38.6 0.60 16 4.07 19.6 499 173 35.6 0.58 17 3.97 19.1 484 168 Amps = outdoor unit amps (comp.+fan) kW = Total system power 39.9 1.00 25 3.88 18.4 442 160 38.8 0.96 26 3.84 18.2 437 159 35.8 0.92 27 3.75 17.8 424 154 67 40.1 0.84 21 3.84 18.2 437 159 39.0 0.80 22 3.81 18.1 433 157 36.0 0.77 22 3.72 17.7 420 152 105ºF 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($ 0³6,1*/(67$*( &217 21 22 www.whirlpoolcomfort.com 56.3 0.88 22 4.45 21.6 259 108 54.7 0.84 23 4.41 21.5 257 107 50.5 0.81 24 4.32 21.0 249 104 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 1584 1810 2036 59 55.4 0.77 19 4.41 21.5 256 107 53.8 0.74 20 4.38 21.3 254 106 49.6 0.71 20 4.28 20.9 246 103 Airflow MBh S/T ΔT 2036 kW Amps Hi PR Lo PR MBh S/T ΔT 1810 kW Amps Hi PR Lo PR MBh S/T ΔT 1584 kW Amps Hi PR Lo PR 58.0 0.79 21 4.54 22.0 279 115 56.3 0.75 21 4.50 21.8 276 114 51.9 0.72 22 4.40 21.4 268 111 63 57.4 0.65 17 4.50 21.8 276 114 55.7 0.62 17 4.47 21.7 273 113 51.4 0.59 18 4.37 21.3 265 109 62.7 0.60 17 4.67 22.5 294 126 60.9 0.57 18 4.64 22.4 292 124 56.2 0.55 18 4.53 21.9 283 121 67 62.9 0.45 13 4.64 22.4 291 124 61.0 0.43 13 4.60 22.2 289 123 56.3 0.41 13 4.50 21.8 280 120 67.3 0.38 12 4.81 23.1 307 134 65.4 0.37 12 4.78 23.0 304 133 60.3 0.35 12 4.67 22.5 295 129 71 55.0 0.91 23 4.77 22.9 291 114 53.4 0.87 24 4.73 22.7 288 113 49.3 0.84 24 4.63 22.3 279 110 59 54.1 0.80 20 4.73 22.7 288 113 52.5 0.76 20 4.70 22.6 285 112 48.5 0.74 21 4.59 22.1 276 109 56.6 0.81 21 4.87 23.3 313 122 55.0 0.78 22 4.83 23.1 310 120 50.7 0.75 22 4.72 22.7 300 117 63 56.1 0.67 17 4.83 23.1 310 120 54.4 0.64 18 4.79 23.0 307 119 50.2 0.62 18 4.68 22.5 297 116 61.3 0.62 17 5.02 23.9 330 133 59.5 0.59 18 4.98 23.7 327 131 54.9 0.57 18 4.86 23.2 317 128 67 61.4 0.46 13 4.98 23.7 327 131 59.6 0.44 13 4.94 23.5 324 130 55.0 0.43 14 4.82 23.1 314 126 75ºF 71 65.8 0.40 12 5.17 24.5 345 141 63.9 0.38 12 5.13 24.4 341 140 58.9 0.36 12 5.01 23.9 331 136 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 53.7 0.93 23 5.06 24.4 331 119 52.1 0.89 24 5.02 24.2 327 118 48.1 0.86 24 4.90 23.7 318 114 59 52.8 0.82 20 5.02 24.2 327 118 51.3 0.78 20 4.98 24.0 324 116 47.3 0.76 21 4.86 23.5 314 113 55.3 0.84 21 5.16 24.8 356 126 53.7 0.80 22 5.12 24.6 352 125 49.5 0.77 22 5.00 24.1 342 121 64.2 0.41 12 5.49 26.2 392 147 62.3 0.39 12 5.45 26.0 388 146 57.5 0.37 12 5.32 25.4 376 141 52.4 0.96 23 5.31 25.6 377 125 50.9 0.92 24 5.27 25.5 373 124 46.9 0.89 24 5.14 24.9 362 120 53.9 0.86 21 5.42 26.1 405 133 52.4 0.82 22 5.38 25.9 401 131 48.3 0.79 22 5.25 25.4 389 128 58.4 0.65 17 5.59 26.8 428 145 56.7 0.62 18 5.55 26.6 424 144 52.3 0.60 18 5.41 26.0 411 139 62.6 0.42 12 5.77 27.6 446 154 60.8 0.40 12 5.72 27.4 442 153 56.1 0.39 13 5.59 26.8 429 148 71 - Shaded area reflects ACCA (TVA) conditions. 59.8 0.63 17 5.32 25.4 376 138 58.1 0.60 18 5.28 25.3 372 137 53.6 0.58 18 5.16 24.7 361 133 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 54.7 59.9 51.5 53.4 58.5 0.69 0.48 0.85 0.71 0.49 17 13 20 17 13 5.12 5.28 5.27 5.38 5.55 24.6 25.3 25.4 25.9 26.6 352 372 373 401 424 125 137 124 131 144 53.1 58.2 50.0 51.8 56.8 0.65 0.45 0.81 0.68 0.47 18 13 21 18 14 5.08 5.24 5.23 5.34 5.50 24.5 25.1 25.3 25.7 26.4 349 368 369 397 419 124 135 122 130 142 49.0 53.7 46.2 47.8 52.4 0.63 0.44 0.78 0.65 0.45 18 14 21 18 14 4.96 5.11 5.10 5.21 5.37 24.0 24.6 24.7 25.2 25.8 338 357 358 385 407 120 131 119 126 138 49.8 1.00 22 5.52 26.9 424 131 48.3 0.95 23 5.48 26.7 419 130 44.6 0.92 24 5.35 26.1 407 126 59 48.9 0.88 19 5.48 26.7 419 130 47.5 0.84 20 5.44 26.5 415 128 43.8 0.81 21 5.31 25.9 403 124 51.2 0.90 21 5.64 27.4 456 139 49.7 0.85 22 5.60 27.2 451 138 45.9 0.82 22 5.46 26.6 438 134 63 50.7 0.74 17 5.60 27.2 451 138 49.2 0.70 18 5.55 27.0 447 136 45.4 0.68 18 5.42 26.4 433 132 59.5 0.44 12 6.01 29.0 502 162 57.8 0.42 12 5.96 28.8 497 160 53.3 0.40 12 5.81 28.2 482 155 71 46.1 1.00 21 5.71 28.2 468 135 44.7 0.96 22 5.66 28.0 463 134 41.3 0.93 22 5.53 27.3 450 130 59 45.3 0.89 18 5.66 28.0 463 134 44.0 0.85 19 5.62 27.8 459 133 40.6 0.82 19 5.48 27.1 445 129 47.5 0.90 19 5.83 28.7 504 144 46.1 0.86 20 5.78 28.5 499 143 42.5 0.83 20 5.64 27.9 484 138 63 47.0 0.74 16 5.78 28.5 499 143 45.6 0.71 16 5.74 28.3 494 141 42.1 0.68 17 5.60 27.7 479 137 51.4 0.68 16 6.02 29.5 532 157 49.9 0.65 17 5.97 29.3 527 156 46.0 0.63 17 5.82 28.6 511 151 67 51.5 0.51 12 5.97 29.3 527 156 50.0 0.49 12 5.92 29.1 521 154 46.1 0.47 13 5.78 28.4 506 149 115ºF 55.1 0.44 11 6.21 30.4 555 167 53.5 0.42 11 6.16 30.2 549 166 49.4 0.40 12 6.01 29.5 533 161 71 - Amps = outdoor unit amps (comp.+fan) kW = Total system power 55.5 0.68 17 5.82 28.2 481 152 53.8 0.65 18 5.77 28.0 477 150 49.7 0.62 18 5.63 27.3 462 146 67 55.6 0.51 13 5.77 27.9 477 150 53.9 0.49 13 5.73 27.7 472 149 49.8 0.47 14 5.59 27.1 458 144 105ºF 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($ 0³7:267$*( WGGE45.00 WGGE45.00 www.whirlpoolcomfort.com 58.3 1.00 26 4.52 21.9 264 110 56.6 0.96 28 4.48 21.7 262 109 52.2 0.93 28 4.38 21.3 254 106 MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR MBh S/T ΔT kW Amps Hi PR Lo PR 1584 1810 2036 59 57.3 0.96 25 4.48 21.7 262 109 55.6 0.92 26 4.45 21.6 259 108 51.4 0.89 26 4.35 21.2 251 105 Airflow MBh S/T ΔT 2036 kW Amps Hi PR Lo PR MBh S/T ΔT 1810 kW Amps Hi PR Lo PR MBh S/T ΔT 1584 kW Amps Hi PR Lo PR 59.4 0.98 26 4.61 22.3 284 117 57.7 0.93 27 4.57 22.1 282 116 53.3 0.90 28 4.47 21.7 273 113 63 58.6 0.90 24 4.57 22.1 282 116 56.9 0.86 25 4.54 22.0 279 115 52.5 0.83 25 4.43 21.5 270 112 62.2 0.88 25 4.74 22.8 300 128 60.4 0.84 26 4.71 22.7 297 127 55.8 0.81 26 4.60 22.2 288 123 67 62.6 0.74 21 4.71 22.7 297 127 60.7 0.70 22 4.67 22.5 294 126 56.1 0.68 22 4.57 22.1 286 122 66.4 0.71 21 4.89 23.4 313 137 64.5 0.68 22 4.85 23.3 310 135 59.5 0.66 23 4.74 22.8 301 131 71 66.9 0.55 17 4.85 23.3 310 135 64.9 0.52 17 4.82 23.1 307 134 59.9 0.51 18 4.70 22.7 298 130 56.9 1.00 26 4.85 23.2 297 117 55.3 1.00 28 4.81 23.0 294 116 51.0 0.96 29 4.70 22.6 285 112 59 56.0 1.00 25 4.81 23.0 294 116 54.3 0.95 26 4.77 22.9 291 114 50.2 0.92 27 4.66 22.4 282 111 58.1 1.00 26 4.94 23.6 319 124 56.4 0.96 28 4.91 23.5 316 123 52.0 0.93 28 4.79 23.0 307 119 63 57.2 0.94 24 4.91 23.5 316 123 55.5 0.89 25 4.87 23.3 313 122 51.3 0.86 26 4.76 22.8 304 118 60.8 0.91 25 5.10 24.2 337 135 59.0 0.87 26 5.06 24.0 334 134 54.5 0.84 27 4.94 23.5 324 130 67 61.1 0.76 21 5.06 24.0 334 134 59.3 0.73 22 5.02 23.9 330 133 54.8 0.70 22 4.90 23.4 321 129 75ºF 64.9 0.74 22 5.26 24.9 352 144 63.0 0.71 23 5.22 24.7 348 143 58.1 0.68 23 5.09 24.2 338 139 71 65.3 0.57 17 5.22 24.7 348 143 63.4 0.54 18 5.17 24.5 345 141 58.5 0.52 18 5.05 24.0 334 137 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 55.6 1.00 25 5.14 24.7 337 121 54.0 1.00 27 5.10 24.5 334 120 49.8 0.99 29 4.98 24.0 324 116 59 54.6 1.00 25 5.10 24.5 334 120 53.0 0.98 26 5.06 24.4 331 119 49.0 0.94 27 4.94 23.9 321 115 56.7 1.00 26 5.24 25.2 363 129 55.0 0.99 28 5.20 25.0 359 128 50.8 0.95 28 5.08 24.5 349 124 59.4 0.94 25 5.41 25.8 383 141 57.6 0.89 26 5.37 25.6 380 139 53.2 0.86 27 5.24 25.1 368 135 54.2 1.00 24 5.39 26.0 384 127 52.7 1.00 27 5.35 25.8 380 126 48.6 1.00 28 5.22 25.3 369 122 55.3 1.00 25 5.51 26.5 413 135 53.7 1.00 27 5.46 26.3 409 134 49.5 0.98 28 5.33 25.7 397 130 57.9 0.97 25 5.68 27.2 437 148 56.2 0.92 26 5.64 27.0 432 146 51.9 0.89 27 5.50 26.4 419 142 61.8 0.78 22 5.87 28.0 455 158 60.0 0.75 23 5.82 27.8 451 156 55.4 0.72 23 5.68 27.2 437 151 71 62.2 0.60 17 5.82 27.8 451 156 60.4 0.58 18 5.77 27.6 446 154 55.7 0.55 18 5.63 27.0 433 150 Shaded area reflects AHRI conditions 63.3 0.76 22 5.58 26.6 400 150 61.5 0.72 23 5.54 26.4 396 148 56.7 0.70 23 5.40 25.8 384 144 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 55.8 59.6 63.8 53.3 54.5 58.2 0.96 0.78 0.58 1.00 1.00 0.81 24 21 17 24 25 21 5.20 5.37 5.54 5.35 5.46 5.64 25.0 25.6 26.4 25.8 26.3 27.0 359 380 396 380 409 432 128 139 148 126 134 146 54.2 57.9 61.9 51.8 52.9 56.5 0.92 0.75 0.56 1.00 0.95 0.77 22 25 22 18 26 25 5.16 5.32 5.49 5.31 5.42 5.59 24.8 25.4 26.2 25.6 26.1 26.8 356 376 392 377 405 428 126 138 147 125 133 145 50.0 53.5 57.1 47.8 48.8 52.1 0.88 0.72 0.54 0.97 0.91 0.74 26 22 18 27 26 22 5.04 5.20 5.36 5.18 5.29 5.46 24.3 24.9 25.6 25.1 25.6 26.2 345 365 380 365 393 415 123 134 143 121 129 141 51.5 1.00 23 5.61 27.3 432 133 50.0 1.00 25 5.57 27.1 428 132 46.2 1.00 27 5.43 26.5 415 128 59 50.6 1.00 23 5.57 27.1 428 132 49.2 1.00 25 5.52 26.9 424 131 45.4 1.01 27 5.39 26.3 411 127 52.5 1.00 24 5.73 27.8 465 142 51.0 1.00 26 5.69 27.6 461 141 47.1 1.00 27 5.55 27.0 447 136 63 51.7 1.00 23 5.69 27.6 461 141 50.2 0.98 25 5.64 27.4 456 139 46.4 0.95 25 5.51 26.8 442 135 58.7 0.81 22 6.11 29.4 512 165 57.0 0.78 22 6.06 29.2 507 163 52.6 0.75 23 5.91 28.6 492 159 71 59.1 0.63 17 6.06 29.2 507 163 57.4 0.60 17 6.01 29.0 502 162 53.0 0.58 18 5.86 28.4 487 157 47.7 1.00 22 5.80 28.6 478 138 46.3 1.00 24 5.75 28.4 473 137 42.8 1.00 25 5.62 27.7 459 133 59 46.9 1.00 21 5.75 28.4 473 137 45.5 1.00 23 5.71 28.2 468 135 42.0 1.02 25 5.57 27.5 454 131 48.7 1.00 22 5.93 29.2 514 147 47.2 1.00 24 5.88 28.9 509 145 43.6 1.00 25 5.74 28.3 494 141 63 47.9 1.00 22 5.88 28.9 509 145 46.5 0.99 23 5.83 28.7 504 144 43.0 0.95 24 5.69 28.1 489 140 51.0 1.00 23 6.12 29.9 543 160 49.5 0.96 24 6.07 29.7 537 159 45.7 0.93 25 5.92 29.0 521 154 67 51.2 0.84 20 6.07 29.7 537 159 49.7 0.81 20 6.02 29.5 532 157 45.9 0.78 21 5.87 28.8 516 152 115ºF 54.4 0.82 20 6.32 30.9 566 171 52.8 0.78 21 6.27 30.6 560 169 48.7 0.75 21 6.11 29.9 544 164 71 54.7 0.63 16 6.27 30.6 560 169 53.2 0.60 16 6.21 30.4 555 167 49.1 0.58 17 6.06 29.7 538 162 Amps = outdoor unit amps (comp.+fan) kW = Total system power 55.0 1.00 25 5.92 28.6 491 155 53.4 0.96 26 5.87 28.4 486 153 49.3 0.92 26 5.73 27.7 472 149 67 55.3 0.84 21 5.87 28.4 486 153 53.7 0.80 22 5.82 28.2 482 152 49.5 0.77 22 5.68 27.5 467 147 105ºF 352'8&763(&,),&$7,216 (;3$1'('&22/,1*'$7$³:**($ 0³7:267$*( &217 23 352'8&763(&,),&$7,216 ',0(16,216     (.7'':*#756  #   $   57%6+10.+37+&24'5574'21465 $'*+0&%1/24'5514#%%'552#0' $ *'#6':%*#0)'#%%'552#0'  5722.;)#5'064#0%' %10&'05#6'&4#+0%100'%6+10 026('/#.'  '8#214#614%10641.2#0'.#%%'552#0'    &+/'05+10 5/#.. /'&+7/ .#4)' +0%*'5 #    $     219'49+4''064#0%' %10641.9+4''064#0%' *11&(.7'':*#756  $.19'4#%%'552#0' %1/$756+10#+4+0.'65     Model Chassis Size A B C WGGE4524A*** Medium 32” 16” 9½” WGGE4537A*** Medium 32” 16” 9½” WGGE4542A*** Large 40” 18” 14” WGGE4560A*** Large 40” 18” 14” 24  www.whirlpoolcomfort.com WGGE45.00 352'8&763(&,),&$7,216 :,5,1*',$*5$06 YL/BK YL LPS BK SEE NOTE 6 S R C RD RD PU T1 BL COMP SOL T2 GND PU YL L1 HPS CC L2 PU BK POWER SUPPLY 208-230/1/60 SEE NOTE 3 BR BK CM PU 1 C BK 3 240 2 208 TR PU GR BK YL 24V GR BL YL/BK BL 6 2 5 1 4 BL PU PU PU RD RD BL C L G N EM 3 BL/PK BL/PK YL/BK BL/PK YL PU WH PU BR PU YL PS LS RS OR OR OR FS YL RD PU YL PU BL 4 24VAC COM BR M H C GV OR WH PU 180 150 120 90 NONE 5 MIN 10 MIN BLOWE R STAGE OFF DE LAY DELAY 2 4 1 YL YL YL BL BL 1 LO HEAT OR W. R. GAS VALVE 3 5 SEE NOTE 7 2 HI HEAT YL OR 6 5 LO COOL 3 HI COOL YL BK T1 YL OR BK L2 LOW HIGH L1 LOW HI ODF PARK INDUCER FS YL PU RD BL IGN ALS BR BK BK PU PU 1 4 7 2 5 8 3 6 9 BR PU YL F ECON R C W1 W2 G Y1 Y2 BR BL VM BL BK RD PU RD YL BL F PU BR BR PU H BK C RCCF RD YL Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING HIGH VOLTAGE! Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. WGGE45.00 www.whirlpoolcomfort.com 25 352'8&763(&,),&$7,216 :,5,1*',$*5$06 &217 SUPPLY VOLTAGE 208-230/1/60 CC L1 T1 C COMP INTEGRATED IGNITION CONTROL L1 LO H RCCF C S L2 HI L1 VM L2 EM L2 L1 SEE NOTE 2 R 3 W1 6 W2 MVL Y1 M MVH HI MVC 5 P2 C LPS 3 SEE NOTE 7 SEE NOTE 8 6 1 ECON 5 2 2 ECON 5 WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW 3. USE COPPER CONDUCTORS ONLY. 4. FOR 208V OPERATION, REMOVE BLUE LEAD FROM INDUCER LOW TERMINAL. MOVE BLACK LEAD FROM PARK TERMINAL ONTO INDUCER LOW TERMINAL. PLACE BLUE LEAD ON PARK TERMINAL. 5. USE NEC CLASS 2 WIRE FOR THERMOSTAT FIELD WIRING. 6. COMPRESSOR 2ND STAGE SOLENOID NOT PRESENT ON ALL MODELS. 7. OPTIONAL REFRIGERANT SWITCHES 8. FOR ECONOMIZER, REMOVE PLUG FROM ECONOMIZER HARNESS. CONNECT PLUG FROM ECONOMIZER TO HARNESS. HPS 5 FIELD WIRING HIGH VOLTAGE LOW VOLTAGE 1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY). 2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. COM 1 LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE NOTES GV 4 INTERGRATED IGNITION CONTROL FACTORY WIRING AUXILLARY LIMIT SWITCH ALS COMP COMPRESSOR CONDENSER MOTOR CM CONTACTOR CC ECON ECONOMIZER EM EVAPORATOR MOTOR F FUSE FLAME SENSOR FS GND EQUIPMENT GROUND GAS VALVE GV IIC INTEGRATED IGNITION CONTROL IGNITOR IGN LS LIMIT SWITCH PS PRESSURE SWITCH RCCF RUN CAPACITOR FOR COMPRESSOR/FAN RS ROLLOUT SWITCH SOL SOLENOID (2ND STAGE COOL) TR TRANSFORMER VM VENT MOTOR PSW 7 C RS PS PSW 9 Y2 LS HLI 8 TO MICRO ALS HLO 1 L2 TR F TH 2 COMPONENT LEGEND L2 L2 F CM LO P1 CC SOL ECON G CC T2 R HI L2 INTEGRATED IGNITION CONTROL L1 TO MICRO OFF ECON 4 LO HEAT HI HEAT LO COOL HI COOL DIAGNOSTIC LED - RED ON 3 T2 T3 T1 EM C T4 STATUS NORMAL OPERATION NO POWER OR INTERNAL CONTROL FAULT CHECK CHECK INPUT POWER CHECK FUSE(S) REPLACE CONTROL GAS FLOW GAS PRESSURE GAS VALVE FLAME SENSOR 1 FLASH IGNITION FAILURE 2 FLASHES PRESSURE SWITCH OPEN CHECK PRESSURE SWITCH CHECK TUBING CHECK VENT MOTOR 3 FLASHES PRESSURE SWITCH CLOSED WITHOUT INDUCER ON CHECK PRESSURE SWITCH CHECK WIRING FOR SHORTS 4 FLASHES OPEN LIMIT SWITCH CHECK MAIN LIMIT SWITCH CHECK AUXILIARY LIMIT SW. CHECK ROLLOUT LIMIT SW. 5 FLASHES FALSE FLAME DETECTED 6 FLASHES COMPR. SHORT CYCLE DELAY CHECK GAS VALVE CHECK FOR SHORTS IN FLAME SENSOR WIRING 3 MIN COMP. SHORT CYCLE DELAY DIAGNOSTIC LED - RED 7 FLASHES STATUS LIMIT OPEN 5 TIMES IN SAME CALL FOR HEAT 8 FLASHES IDT/ODT OPEN 9 FLASHES PSW/LOC OPEN DIAGNOSTIC LED - AMBER OFF ON 1 FLASH 2 FLASHES STATUS NO FLAME PRESENT NORMAL FLAME PRESENT LOW FLAME SIGNAL FALSE FLAME DETECTED CHECK CHECK MAIN LIMIT SWITCH CHECK AUXILIARY LIMIT SW. CHECK JUMPER BETWEEN 1 AND 4 ON 6-CIRCUIT CONNECTOR CHECK OPTIONAL REFRIGERANT SWITCHES CHECK REFRIGERANT SWITCHES FOR LOSS OF CHARGE OR HIGH HEAD PRESSURE CHECK GAS FLOW GAS PRESSURE GAS VALVE FLAME SENSOR CHECK GAS VALVE CHECK FOR SHORTS IN FLAME SENSOR WIRING 0140G00533 REV A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 26 www.whirlpoolcomfort.com WGGE45.00 352'8&763(&,),&$7,216 $&&(6625,(6 Description Concentric Converter Part Numbers Small Chassis CDK1-2 Horizontal Duct Cover --- Medium Chassis Large Chassis CDK1-2 CDK3 20464501PDGK 20464502PDGK Downflow Economizer PGED101 PGED102 PGED103 Horizontal Economizer PGEH101 PGEH102 PGEH103 Filter Rack PGFR101 PGFR102 PGFR103 Downflow Manual Damper PGMDD101 PGMDD102 PGMDD103 Downflow Motorized Damper PGMDMD101 PGMDMD102 PGMDMD103 Horizontal Manual Damper PGMDH101 PGMDH102 PGMDH103 Horizontal Motorized Damper PGMDMH101 PGMDMH102 PGMDMH103 Roof Curb PGC101 PGC102 PGC103 Downflow Square-to-Round SQRPG101 SQRPG102 SQRPG103 Horizontal Square-to-Round SQRPGH101 SQRPGH102 SQRPGH103 The above accessories are offered by McDaniel Metals • Main: (281) 987-8400 • Fax: (281) 987-9494 LPT-00A WGGE45.00 L.P. Conversion Kit www.whirlpoolcomfort.com 27 352'8&763(&,),&$7,216 127(6 Whirlpool® is a trademark of Whirlpool Corporation and used under license to Tradewinds Distributing Co. LLC. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. © 2009 • Tradewinds Distributing Co. LLC. • Jacksonville, FL • Printed in the USA. 28 www.whirlpoolcomfort.com WGGE45.00