Transcript
PRODUCT DATASHEET
LCF38-50J
3/8" CELLFLEX® Low-Loss Foam-Dielectric Coaxial Cable CELLFLEX® 3/8" low loss flexible cable FEATURES / BENEFITS Low Attenuation The low attenuation of CELLFLEX® coaxial cable results in highly efficient signal transferin your RF system. Complete Shielding The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes system interference. Low VSWR Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise. Outstanding Intermodulation Performance CELLFLEX®FRD[LDOFDEOH VVROLGLQQHUDQGRXWHUFRQGXFWRUVYLUWXDOO\HOLPLQDWHLQWHUPRGV Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory. High Power Rating Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels. Wide Range of Application Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects.
3/8" CELLFLEX® Low-Loss Foam Dielectric Coaxial Cable
Technical Features APPLICATIONS Applications
OEM jumpers, BTS inter-cabinet connections, GPS lines, Microwave IF cabling
STRUCTURE Cable Type Size Jacket Option Inner Conductor Dielectric Outer Conductor Jacket
mm (in) mm (in) mm (in) mm (in)
Foam-Dielectric, Corrugated 3/8" Black 3.1 (0.12) Copper-Clad Aluminum Wire 7.2 (0.28) Foam Polyethylene 9.5 (0.37) Corrugated Copper 11.2 (0.44) Polyethylene, PE
ELECTRICAL SPECIFICATIONS ȍ GHz % pF/m (pF/ft) µH/m (µH/ft) kW Volts Volt RMS ȍm ȍft) ȍm ȍft)
Impedance Maximum Frequency Velocity Capacitance Inductance Peak Power Rating RF Peak Voltage Jacket Spark Inner Conductor dc Resistance Outer Conductor dc Resistance Return Loss (VSWR) Performance Maximum Return Loss Phase Stabilized Temperature & Power
dB (VSWR)
50 +/- 1.5 13.5 88 76 (23.2) 0.19 (0.058) 15.4 1240 5000 3.8 (1.16) 2.9 (0.88) Standard Contact RFS for your VSWR performance specification for your required frequency band. Phase stabilized and phase matched cables and assemblies are available upon request. Standard
MECHANICAL SPECIFICATIONS Cable Weight Minimum Bending Radius, Single Bend Minimum Bending Radius, Repeated Bends Bending Moment Tensile Strength Recommended / Maximum Clamp Spacing
LCF38-50J
REV: E
kg/m (lb/ft) mm (in) mm (in) Nm (lb*ft) N (lb) m (ft)
0.12 (0.08) 50 (2) 95 (4) 1.9 (1.4) 530 (119) 0.5 / 1 (1.75 / 3.25)
REV DATE: 19.Feb.2013
All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering
www.rfsworld.com Page 1 of 2
PRODUCT DATASHEET
LCF38-50J
3/8" CELLFLEX® Low-Loss Foam-Dielectric Coaxial Cable ATTENUATION AND POWER RATING Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 900 925 960 1000 1250 1500 1700 1800 2000 2100 2200 2400 3000 3500 4000 5000 6000 7000 8000 9000 10000 12000 13500
Attenuation dB/100m dB/100ft 0.24 0.072 0.34 0.102 0.41 0.125 0.48 0.145 1.07 0.325 1.51 0.461 1.86 0.566 2.41 0.734 3.21 0.978 3.43 1.04 3.56 1.09 4.21 1.28 4.55 1.39 4.89 1.49 6.02 1.84 7.00 2.13 7.44 2.27 7.86 2.40 7.96 2.43 8.65 2.64 9.38 2.86 10.10 3.07 10.20 3.12 10.70 3.25 10.70 3.27 10.90 3.31 11.10 3.38 11.30 3.45 12.80 3.89 14.10 4.29 15.10 4.59 15.50 4.74 16.50 5.01 16.90 5.15 17.30 5.28 18.20 5.54 20.50 6.26 22.40 6.82 24.10 7.35 27.40 8.34 30.30 9.25 33.20 10.10 35.80 10.90 38.40 11.70 40.80 12.40 45.50 13.90 48.80 14.90
Power kW 15.40 15.40 15.40 15.20 6.79 4.79 3.90 3.01 2.26 2.12 2.04 1.72 1.59 1.48 1.20 1.04 0.975 0.923 0.911 0.838 0.773 0.72 0.709 0.679 0.677 0.667 0.654 0.64 0.568 0.515 0.481 0.467 0.441 0.429 0.418 0.399 0.353 0.324 0.301 0.265 0.239 0.219 0.202 0.189 0.178 0.159 0.149
TESTING AND ENVIRONMENTAL Fire Performance Installation Temperature Storage Temperature Operation Temperature
Halogene Free -40 to 60 (-40 to 140) °C(°F) -70 to 85 (-94 to 185) °C(°F) -50 to 85 (-58 to 185) °C(°F)
Attenuation at 20°C (68°F) cable temperature; tolerance +/- 5% max.; Mean power rating at 40°C (104°F) ambient temperature
External Document Links
Notes Phase stabilized versions available upon request.
LCF38-50J
REV: E
REV DATE: 19.Feb.2013
All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering
www.rfsworld.com Page 2 of 2