Preview only show first 10 pages with watermark. For full document please download

312786f Dump Valve And Third Purge Valve Kits

   EMBED


Share

Transcript

Instructions-Parts Dump Valve and Third Purge Valve Kits 312786F EN For use with ProMix® 2KS Electronic Proportioners. For professional use only. See page 2 for kit part numbers and maximum working pressure. Important Safety Instructions Read all warnings and instructions in this manual. For complete warnings and instructions see your proportioning system manual. Hazard symbols refer to specific procedure risks. Save all instructions. 15V821 Dump Valve Kit for Wall Panel 15V354 Third Flush Valve Kit for Wall Panel, shown on Fluid Mix Manifold TI12743a TI12954a Kits Kits 15V821 Dump Valve Kit For wall mount ProMix 2KS Electronic Proportioners 3000 psi (21 MPa, 210 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Working Pressure See pages 3 and 14 15V822 Robo Dump Valve Kit For robo mount ProMix 2KS Electronic Proportioners 300 psi (2.1 MPa, 21 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Working Pressure See pages 6 and 16 15V354 Third Flush Valve Kit For wall mount ProMix 2KS Electronic Proportioners 4000 psi (28 MPa, 280 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Working Pressure See pages 5 and 15 15V202 Robo Third Flush Valve Kit For robo mount ProMix 2KS Electronic Proportioners 300 psi (2.1 MPa, 21 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Working Pressure See pages 7 and 17 15X247 Auto Dump Valve Kit For wall mount ProMix 2KS Electronic Proportioners 3000 psi (21 MPa, 210 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Working Pressure See pages 8 and 18 2 312786F Installation Installation 15V821 Dump Valve Kit for Wall Panel NOTE: These instructions show this kit being installed on the A side. It may also be installed on the B side. 5. Install the dump valve assembly (includes 1, 2, 4, and 11) in a slot of the flange (F) at the back of the wall panel. Secure with the nut (8). 6. Install the elbow (6) in the open port of the dump valve adapter (2). Connect a 1/4 npsm(f) hose (12) between the elbow (6) and nipple (19). 1. Shut off the fluid supply to the dose valve (V) at the front of the wall panel. 2. Actuate the dose valve to relieve fluid pressure in the valve. 3. Relieve fluid pressure upstream and downstream of the dose valve. See your ProMix 2KS Operation Manual. 4. See FIG. 1. Remove the plug from the dose valve adapter. Install the street elbow (18) in this port. Install the nipple (19) in the elbow. 7. Shut off all power to the fluid panel. Open the fluid panel. See the Wall Panel detail in FIG. 2. Install the solenoid (9) at the correct position (Dump Valve A or Dump Valve B) on the solenoid manifold. Connect the solenoid wires to the fluid panel control board as shown in FIG. 3. Also see the System Electrical Schematic on page 13. 8. Connect the tubing (7) between the solenoid manifold and the tube fitting (T) on the dump valve (1). See System Pneumatic Schematic, page 10. At Front of Wall Panel A SIDE At Back of Wall Panel B SIDE 1 12 V 12 T 18 19 TI12744a 6 F 8 2 TI12743a FIG. 1: 15V821 Kit Installation 312786F 3 Installation Wall Panel RoboMix Panel Dump Valve B Dump Valve A 3rd Flush Valve TI12655a Dump Valve B Dump Valve A GFB2 3rd Flush Valve GFB1 TI13116a FIG. 2: Solenoid Manifolds J15-1 J15-2 J15-5 J15-6 J8-1 J8-2 J8-3 J8-4 J8-5 J8-6 3rd Purge Valve Dump Valve A Dump Valve B Auto Dump Valve A (GFB1) Auto Dump Valve B (GFB2) Wire Color J15-1 J15-5 J8-5 J8-3 J8-1 Red J15-2 J15-6 J8-6 J8-4 J8-2 Black FIG. 3: 255765 Fluid Panel Control Board, Detail View of Solenoid Connections 4 312786F Installation 15V354 Third Flush Valve Kit for Wall Panel 7. Connect the tubing (13, 14) between the solenoid manifold and the tube fittings (T) on the flush valve (2). See System Pneumatic Schematic, page 10. 1. Shut off the air and fluid supply to the ProMix 2KS. 2. Relieve pressure. See your ProMix 2KS Operation Manual. 3. See FIG. 4. Remove the air flush valve (AFV) from the fluid mix manifold (FM) and set it aside. 6 1 8 FM TI12956a FIG. 5: Install Double Valve Mounting Block AFV 1 TI12955a FIG. 4: Disconnect Air Flush Valve AFV 7 4. See FIG. 5. Install the o-ring (6), double valve mounting block (1), and screws (8). 2 5. See FIG. 6. Install the air flush valve (AFV) on the double valve block (1). Assemble the third flush valve kit parts (2, 3, 4, 6, 9, 10, 11) as shown on page 15. Install on the mounting block using the screws (7). See FIG. 6. TI12957a FIG. 6: Install Third Flush Valve 6. Shut off all power to the fluid panel. Open the fluid panel. See the Wall Panel detail in FIG. 2. Install the solenoid (12) and two tube connectors (15) at the correct position (3rd Flush Valve) on the solenoid manifold. Connect the solenoid wires to the fluid panel control board as shown in FIG. 3. 312786F 5 Installation 15V822 Dump Valve Kit for RoboMix NOTE: These instructions show this kit being installed on the B side. It may also be installed on the A side. 1. See FIG. 7. Shut off the fluid supply to the dose valve (V) in the RoboMix. 2. Actuate the dose valve to relieve fluid pressure in the valve. 3. Relieve fluid pressure upstream and downstream of the dose valve. See your ProMix 2KS Operation Manual. 4. Remove the plug from the dose valve adapter. Apply thread sealant and install the elbow (8) in this port. 5. Install the valve adapter (3) in the RoboMix. Secure with four screws (11). Apply thread sealant and install the nipple (9) through the back of the RoboMix and into the adapter. Install the swivel (6) in the opposite side of the adapter. 6. Install the seat (2), o-ring (10), and dump valve (1) in the adapter (3). 7. Connect the hose (5) between the swivel (6) and elbow (8). 8. Shut off all power to the fluid panel. Open the fluid panel. See the RoboMix Panel detail in FIG. 2. Install the solenoid (4) at the correct position (Dump Valve A or Dump Valve B) on the solenoid manifold. Connect the solenoid wires to the fluid panel control board as shown in FIG. 3. Also see the System Electrical Schematic on page 13. 9. Connect the tubing (13) between the solenoid manifold and the tube fitting (T) on the dump valve (1). See System Pneumatic Schematic, page 10. 6 312786F Installation 1 T 10 2 3 6 TI12655a Dump Valve B 5 V Dump Valve A 8 4 11 9 TI13047a TI13045a FIG. 7: 15V822 Kit Installation 15V202 Third Flush Valve Kit for RoboMix 7. Install the o-ring (2), seat (1), o-ring (6), and third flush valve (5) in the adapter (3). 1. Shut off the air and fluid supply to the ProMix 2KS. 2. Relieve pressure. See your ProMix 2KS Operation Manual. 3. See FIG. 8. Remove the plug (A) from the air flush valve (AFV). Install an o-ring (6) in this port. 4. Install the third flush valve adapter (3) in the RoboMix. Ensure that the o-ring (6) remains in place to seal between the adapter and the air flush valve adapter. 5. Secure the adapter (3) to the air flush valve adapter with four screws (10) inserted through the side wall of the RoboMix. Torque to 70 in-lb (8 N•m). 6. Apply thread sealant and install the check valve (4) through the back of the RoboMix and into the third flush valve adapter (3). 312786F 8. See FIG. 8. Shut off all power to the fluid panel. Open the fluid panel. Install the solenoid (8) in the third flush valve position on the solenoid manifold. Install the tube connector (9). Connect the solenoid wires to the fluid panel control board as shown in FIG. 3. Also see the System Electrical Schematic on page 13. 9. Connect the tubing (13) between the solenoid manifold and the tube fitting (T) on the third flush valve (5). See System Pneumatic Schematic, page 10. 10. Connect the third flush fluid supply line to the check valve (4). 7 Installation 9 5 T 6 1 3 6 TI12655a 2 8 4 10 TI13046a TI13047a FIG. 8: 15V202 Kit Installation 15X247 Auto Dump Valve Kit 6. Connect a 1/4 npsm(f) dump hose (not supplied) to the 1/4 npsm(m) threaded stud at the bottom of the adapter (2). When the gun closes, the dump valve opens and fluid is dumped through the stud. 1. Close the component A and component B shutoff valves on the fluid manifold. 2. Trigger the gun to relieve fluid pressure downstream of the fluid manifold. 3. See FIG. 9. Install the small o-ring (3), seat retainer (6), large o-ring (7), and dump valve (1) in the valve adapter (2). Install the breather vent (17). 4. Install the valve adapter (2) in the mixed material line, downstream of the static mixer and as close to the gun as possible. NOTE: Connect the static mixer to one 1/4 npt port of the valve adapter. 5. Install the nipple (8) in the other port of the adapter (2). Connect the gun line to this nipple. 8 7. Shut off all power to the fluid panel. Open the fluid panel. See the Wall Panel detail in FIG. 9. Install the solenoid (5) at the correct position (GFB1 or GFB2) on the solenoid manifold. Connect the solenoid wires to J8 on the fluid panel control board as shown in FIG. 3. Also see the System Electrical Schematic on page 13. 8. Install the tube connector (9) in the solenoid manifold. Connect the tubing (4) between the connector and the tube fitting (T) on the dump valve (1). See System Pneumatic Schematic, page 10. 312786F Installation 17 1 T 7 6 3 8 GFB1 GFB2 2 J8 (see FIG. 3 for details) 9 5 TI14283a 4 TI13116a Wall Panel FIG. 9: 15X247 Kit Installation 312786F 9 Schematic Diagrams Schematic Diagrams System Pneumatic Schematic COLOR CHANGE CONTROL A B E BE OS CL 2 TU / 53 N E OP DOSE A VALVE 12 VDC 4-WAY SOLENOID A B E BE OS CL 2 TU 5/3 N E OP A B E BE OS CL 2 TU 5/3 N E OP DOSE B VALVE 12 VDC 05 AIR INPUT 4-WAY SOLENOID CONTROL AIR 3/8 AIR FILTER MANUAL DRAIN 5 MICRON WALL MOUNT ONLY PURGE A VALVE COLOR 1 COLOR 2 COLOR 3 COLOR 4 COLOR 5 COLOR 6 COLOR 7 COLOR 8 COLOR SOLVENT COLOR 9 COLOR 10 COLOR 11 COLOR 12 CATALYST 1 CATALYST 2 CATALYST 3 CATALYST 4 CATALYST SOLVENT 12 VDC 4-WAY SOLENOID A B E BE OS CL 2 TU 5/3 N E OP PURGE B VALVE E BE OS CL 2 TU / 53 N E OP PURGE C VALVE (OPTIONAL) E DUMP A VALVE (OPTIONAL) E DUMP B VALVE (OPTIONAL) 12 VDC 4-WAY SOLENOID A B AIR EXHAUST MUFFLER PURGE AIR 1/4 TUBE 12 VDC 4-WAY SOLENOID TO MANIFOLD MANIFOLD FLUSH AIR TO FLUID INLET 1/4 TUBE AIR EXHAUST MUFFLER COLOR VALVE STACKS 12 VDC 3-WAY SOLENOID A UB 2T 5/3 N E OP A UB 2T 5/3 N E OP AIR INPUT 12 VDC 3-WAY SOLENOID MAC 36 SERIES SOLENOID VALVES 12 VDC 3-WAY SOLENOID COLOR 13 COLOR 14 COLOR 15 COLOR 16 COLOR 17 COLOR 18 COLOR 19 COLOR 20 COLOR 21 COLOR 22 COLOR 23 COLOR 24 COLOR 25 COLOR 26 COLOR 27 COLOR 28 COLOR 29 COLOR 30 E GFB 1 VALVE (OPTIONAL) E GFB 2 VALVE (OPTIONAL) A UB 2T 5/3 N E P O A UB 2T 5/3 N E P O 12 VDC 3-WAY SOLENOID MANIFOLD 10 312786F Schematic Diagrams Tubing Schematic B3 13 B1 13 GFB1-P A2 GFB2-P A6 B7 B5 DB AT A4 DA A8 TI13857a B1 B3 B5 B7 GFB1-C TI13858a GFB2-C GFB1-A GFB2-A TI13862a A2 A4 A6 A8 DA DB GFB1-P GFB1-A ATOM-1 GFB1 GFB2 GFB1-C GFB1-S GFB2-P GFB2-A GFB2-C GFB2-S TI13863a 312786F GFB1-S GFB2-S ATOM-1 TI13861a ATOM-2 ATOM-2 TI13860a 11 Schematic Diagrams Table 1: Tubing Chart Color Description Starting Point Ending Point Tube OD in. (mm) Tube Ref. No. Green Dose A On A2 A2 5/32 (4) 336 Green Dose B On A4 A4 5/32 (4) 336 Green Purge A On A6 A6 5/32 (4) 336 Green Purge B On A8 A8 5/32 (4) 336 Green Dump A DA DA 5/32 (4) Green Dump B DB DB 5/32 (4) Included in optional Dump Valve Kit 15V821 Red Dose A Off B1 B1 5/32 (4) 337 Red Dose B Off B3 B3 5/32 (4) 337 Red Purge A Off B5 B5 5/32 (4) 337 Red Purge B Off B7 B7 5/32 (4) 337 Natural Solenoid Air Supply 13 13 1/4 (6) 334 Natural Gun Flush Box 1 Pressure GFB1-A Switch Signal GFB1-A 5/32 (4) Natural Gun Flush Box 2 Pressure GFB2-A Switch Air GFB2-A 5/32 (4) Natural Gun Flush Box 1 Trigger Air GFB1-C GFB1-C 5/32 (4) Natural Gun Flush Box 2 Trigger Air GFB2-C GFB2-C 5/32 (4) Natural Gun Flush Box 1 Supply Air GFB1-P GFB1-P 5/32 (4) Natural Gun Flush Box 2 Supply Air GFB2-P GFB2-P 5/32 (4) Natural Gun Flush Box 1 Safety Interlock GFB1-S GFB1-S 5/32 (4) Natural Gun Flush Box 2 Safety Interlock GFB2-S GFB2-S 5/32 (4) Natural Gun 1 Atomizing Air ATOM-1 ATOM-1 1/4 (6) Natural Gun 2 Atomizing Air ATOM-2 ATOM-2 1/4 (6) User supplied. Connects air flow switch to gun air shutoff valve. Natural Purge Air Supply Use as a separate line AT connected directly to the main shop air line. Do not connect to the unit’s main air supply or to the air manifold (335). 1/4 (6) 338 12 Included in optional Gun Flush Box Kit 15V826 312786F Schematic Diagrams System Electrical Schematic Hazardous Area HAZARDOUS AREA FLUID PANEL CONTROL BOX 3X CABLE FLUID PANEL CONTROL BOARD J3 J12 J10 J13 1 +12VDC I/S 2 COM 3 SHIELD J5 1 2 3 4 5 6 PWR (RED) COM (BLACK) SIG (WHITE) SHIELD/GRN PWR (RED) COM (BLACK) SIG (WHITE) SHIELD/GRN PWR (RED) COM (BLACK) SIG (WHITE) SHIELD/GRN 1 2 3 4 5 6 FLOW METER A I.S. METERS FLOW METER B FLOW METER SOLVENT J2 J1 UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED 1 2 3 4 5 6 1 FLOW 2 CONTROL 3 BOARD 4 5 V/P ANALOG OUT (WHT) PRESS. (GRN) +12 V (RED) GND (BLK) CHASSIS (BARE) GROUND TERMINAL (10')/ (40') 1 2 SIG (RED) COM (BLK) TECNO V/P + PRESSURE (GRN) COM (RED) EX+ (WHT) - PRESSURE (BLK) SHIELD (BARE) FLUID PRESS. SENS. J4 1 2 3 4 5 1 2 3 4 5 6 MH2 J7/J11 1 4 5 2 3 COLOR BOARD 1 (COLORS 1 THRU 12, CATALYST 1 THRU 4) 6' STD. (3'-100' OPTIONS) J11 3 2 5 4 1 GRD (BLK) +12VDC (RED) SHIELD (BARE) CAN H (WHT) CAN L (BLU) CLR 7 50' STD. J7 3 2 5 4 1 3 2 5 4 1 GRD (BLK) +12VDC (RED) SHIELD (BARE) CAN H (WHT) CAN L (BLU) CLR 6 BOOTH CONTROL BOARD CLR 5 CLR 4 CLR 3 CLR 2 MANIFOLD J15 J14 J9 312786F FO OUT (BLU) J4 FO IN (BLK) J6 J1 6 5 4 3 2 1 6 5 4 3 2 1 BLACK RED BLACK RED BLACK RED BLACK RED BLACK RED BLACK RED 1 2 3 4 5 6 7 8 9 10 SIG COM SIG COM SIG COM SIG COM SIG COM CLR 1 DUMP B GFB #1 GFB #2 DUMP A MANIFOLD NOT USED SOL CLR +12VDC COM +12VDC COM +12VDC COM 1 2 3 4 5 6 +12VDC COM +12VDC COM +12VDC COM 1 2 3 4 5 6 +12VDC COM +12VDC COM +12VDC COM 1 2 3 4 5 6 PURGE A NOT USED NOT USED DOSE B J10 6 5 4 3 2 1 COM +12VDC COM +12VDC COM +12VDC CLR 12 6 5 4 3 2 1 COM +12VDC COM +12VDC COM +12VDC CAT 2 CLR 10 CLR 11 CAT 4 CAT 3 CAT 1 SOL CAT 6' STD. 1 4 5 2 3 COLOR BOARD 2 (COLORS 13 THRU 30) MANIFOLD CLR 21 CLR 20 CLR 19 CLR 18 CLR 17 CLR 16 CLR 15 AIR FLOW SWITCH 1 J14 J16 CLR 9 J7/J11 DOSE A CLR 14 CLR 13 AIR FLOW SWITCH 2 J15 J9 COM +12VDC COM +12VDC COM +12VDC J7/J11 PURGE C PURGE B J8 6 5 4 3 2 1 1 4 5 2 3 12 VDC 3-WAY SOLENOID BLACK RED BLACK RED BLACK RED BLACK RED BLACK RED BLACK RED 12 VDC 4-WAY SOLENOID J8 6 5 4 3 2 1 6 5 4 3 2 1 MANIFOLD MANIFOLD CLR 8 MANIFOLD +12VDC COM +12VDC COM +12VDC COM 1 2 3 4 5 6 J8 +12VDC COM +12VDC COM +12VDC COM 1 2 3 4 5 6 J15 +12VDC COM +12VDC COM +12VDC COM 1 2 3 4 5 6 J14 J9 J16 J10 6 5 4 3 2 1 COM +12VDC COM +12VDC COM +12VDC CLR 22 6 5 4 3 2 1 COM +12VDC COM +12VDC COM +12VDC CLR 25 6 5 4 3 2 1 COM +12VDC COM +12VDC COM +12VDC CLR 28 CLR 23 CLR 24 CLR 26 CLR 27 CLR 29 CLR 30 SOLVENT FLOW SWITCH GFB 1 PRESSURE SWITCH GFB 2 PRESSURE SWITCH 13 Parts Parts 15V821 Dump Valve Kit for Wall Panel 17* 18 1* 19 *14 *11 *4 *2 15 A B 12 6 13 8 7 TI12742a Ref. No. 1* Part No. Description Qty 15X303 VALVE, dispense; includes items 1 14 and 17; see manual 312782 2* 15T717 ADAPTER, dump valve 1 4*† 111457 O-RING; ptfe 1 6 114342 ELBOW; 1/4 npt (mbe) 1 7 n/a TUBE; nylon; 5/32 in. (4 mm) OD; 1 2 ft (0.61 m) 8* n/a NUT, hex; 9/16-18 1 9 121324 VALVE, solenoid, dump valve 1 11*† n/a SEAT, dump valve; sst 1 9 TI13116a Ref. No. 12 13 Part No. Description Qty 206966 HOSE; 1-1/2 ft (0.46 m) 1 111328 CONNECTOR; 10-32 x 5/32 in. (4 1 mm) OD tube 14*† n/a O-RING; ptfe 1 15 101970 PLUG 1 17* 15V818 VENT, breather 1 18 166866 ELBOW, street; 1/4 npt (m x f) 1 19 C20482 NIPPLE; 1/4 npt 1 * Parts included in 16A079 Dump Valve Replacement Kit (purchase separately). † Order Kit 16A560 to replace a single seat. The kit includes a seat (11) and o-rings (4 and 14). NOTE: The standard valve seat (11) is SST. To install a carbide seat, order Kit 24U054. The kit includes a single carbide seat and o-rings 4 and 14. Parts labeled n/a are not available separately. 14 312786F Parts 15V354 Third Flush Valve Kit for Wall Panel 6 8 ‡11 3 7 5 1 2 ‡4 TI12953a ‡6 10 9 12 Ref. No. 1 2 3 4‡ 5 6‡ 7 8 9 10 Part No. Description Qty 15U673 BLOCK, double valve mount 1 15X303 VALVE, dispense; includes item 4; 1 see manual 312782 15T600 ADAPTER, valve 1 n/a O-RING; ptfe 2 101970 PLUG, pipe; 1/4 npt 3 109450 O-RING; ptfe 5 n/a SCREW, cap, socket-hd; 5/16-24 x 2 3/4 in. (19 mm) 109031 SCREW, cap, socket-hd; 5/16-24 x 2 1 in. (25 mm) 166866 ELBOW, street; 1/4 npt (m x f) 1 501867 VALVE, check 1 312786F Ref. No. 11‡ 12 13 14 15 15 TI12652a Part No. n/a 121374 n/a Description Qty SEAT, valve 1 VALVE, solenoid, 4-way 1 TUBE; nylon; 5/32 in. (4 mm) OD; 3 1 ft (0.9 m); green n/a TUBE; nylon; 5/32 in. (4 mm) OD; 3 1 ft (0.9 m); red 114263 CONNECTOR; 1/8 npt(m) x 5/32 in. 2 (4 mm) OD tube ‡ Parts included in Valve Seat Kit 24A861 (purchase separately). Parts labeled n/a are not available separately. 15 Parts 15V822 Dump Valve Kit for RoboMix 1 TI12655a 10 2 Dump Valve B 3 Dump Valve A 6 5 4 8 11 TI13047a 9 TI13045a Ref. No. 1 2 3 4 5 6 8 9 10 16 Part No. Description Qty 15X304 VALVE, dispense; includes item 10; 1 see manual 312782 15V888 RETAINER, seat, RoboMix 1 15U713 VALVE, adapter; RoboMix 1 121795 VALVE, solenoid, 4-way 1 15U720 HOSE; 1/4 npt (mbe); 15-1/2 in. 1 (394 mm); ptfe 114339 UNION, swivel; 1/4 npt 1 114446 ELBOW; 1/4 npt(m) x 1/4 npsm(f) 1 166421 NIPPLE; 1/4 npt 1 n/a O-RING; ptfe 1 Ref. No. 11 12 13 14 15 16 Part No. Description Qty C19979 SCREW, cap, socket-hd; 10-24 x 4 3/8 in. (10 mm) 111328 CONNECTOR; 10-32 x 5/32 in. (4 1 mm) OD tube n/a TUBE; nylon; 5/32 in. (4 mm) OD; 3 1 ft (0.9 m); green 114342 ELBOW; 1/4 npt (mbe) 1 104644 PLUG, screw 1 104640 GASKET; buna-N 1 Parts labeled n/a are not available separately. 312786F Parts 15V202 Third Flush Valve Kit for RoboMix 9 5 6 1 3 2 TI12655a 8 4 10 TI13046a Ref. No. 1 2 3 4 5 6 8 9 10 13 TI13047a Part No. 15V888 109450 15U715 501867 15X304 Description Qty RETAINER, seat, RoboMix 1 O-RING; ptfe 1 VALVE, adapter; RoboMix 1 VALVE, check 1 VALVE, dispense; includes item 6; 1 see manual 312782 n/a O-RING; ptfe 2 121795 VALVE, solenoid, 4-way 1 111328 CONNECTOR; 10-32 x 5/32 in. (4 1 mm) OD tube 110420 SCREW, cap, socket-hd; 10-24 x 4 1-1/2 in. (38 mm) n/a TUBE; nylon; 5/32 in. (4 mm) OD; 2 1 ft (0.61 m); green Parts labeled n/a are not available separately. 312786F 17 Parts 15X247 Auto Dump Valve Kit 17 1 7 6 3 8 GFB1 GFB2 2 9 5 TI14283a Ref. No. 1 2 3† 4 5 6† 7† 8 9 17 4 TI13116a Part No. Description Qty 15X303 VALVE, dispense; includes items 7 and 17; see man- 1 ual 312782 15T717 ADAPTER, dump valve 1 111457 O-RING; ptfe 1 n/a TUBE; nylon; 5/32 in. (4 mm) OD; 5 ft (1.52 m) 1 121324 VALVE, solenoid, dump valve 1 n/a SEAT, dump valve; sst 1 n/a O-RING; ptfe 1 C20482 NIPPLE; 1/4 npt 1 111328 CONNECTOR; 10-32 x 5/32 in. (4 mm) OD tube 1 15V818 VENT, breather 1 † Order Kit 16A560 to replace a single seat. The kit includes a seat (6) and o-rings (3 and 7). NOTE: The standard valve seat (6) is SST. To install a carbide seat, order Kit 24U054. The kit includes a single carbide seat and o-rings 3 and 7. Parts labeled n/a are not available separately. 18 312786F Notes Notes 312786F 19 Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées. Graco Information For the latest information about Graco products, visit www.graco.com. For patent information, see www.graco.com/patents. TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505 All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English. MM 312786 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS, MN 55440-1441 • USA Copyright 2008, Graco Inc. All Graco manufacturing locations are registered to ISO 9001. www.graco.com Revision F, February 2014