Preview only show first 10 pages with watermark. For full document please download

3390 Gagemount Datasheet English

   EMBED


Share

Transcript

3390 Gagemount Accurate, Reliable Weighing for Heavy-Capacity Tanks Tank Weighing Gagemount weigh modules offer the rugged construction needed for use with heavy-capacity tank scales. Available in capacities of 200t – 300t, they are designed to handle extremely heavy loads. Load Cells Model 0782 analog load cells have a rocker-column design that automatically aligns load forces for accurate weighing. These hermetically sealed load cells are rated IP68 and can be used in all environments. Because there are no bolted connections, the load cells are easy to inspect or replace. 200t–300t 3390 Gagemount Weigh Module Gagemount weigh modules enable you to convert a heavy-capacity tank, silo, or hopper into a scale. They can be adapted to a wide range of applications, including tanks used for filling, mixing, batching, and inventory management. Regardless of the application, these easy-to-install weigh modules can deliver accurate and repeatable performance in heavy-duty weighing environments. • Hermetically sealed load cells • Stainless steel load cells (200t) • Nickel-plated carbon steel 200t–300t or electropo­ lished stainless steel 200t mounting hardware 3390 Weigh Module Specifications Weigh Module Model No. Rated Capacity (R.C.) Load Limit, safe 6) Restoring Force 5) Max. horizontal force Max. top plate travel Unit of Measure t (klb, nominal) %R.C. %A.L./mm (../in) 3) transverse longitudinal transverse longitudinal Load Cell Model No. Rated Capacity (R.C.) Rated Output Combined Error 1) 2) Unit of Measure Temperature Range ATEX Approval 4) t (klb, nominal) mV/V @R.C. %R.C. %R.C./°C (../°F) %A.L./°C (../°F) °C (°F) Rating Entity Parameters Rating Factory Mutual Approval 4) Excitation Voltage Terminal Resistance Material Protection Load Limit Number, USA Number, Canada Recommended Max. Excitation Output Spring Element Type IP Rating NEMA Rating Safe Ultimate Deflection @ R.C., nominal Weight, nominal Cable Length Diameter V AC/DC Ω %R.C. mm (in) kg (lb) m (ft) mm (in) 300 (661) 125 1.6 (40) 2.5 (63) 0 (0) ± mm (in) kN (klb) kg (lb) Min. Dead load Output Sensitivity 2) Compensated Operating Safe Storage 200 (441) kN (klb) Max. Uplift Force Weight (including load cell), nominal Material Finish Temperature Effect on Specification 3390 Gagemount 7) 6 (0.24) 7) 0 (0) 7) 55 (121) carbon steel / 304 stainless steel nickel plated / electropolished 125 (275) carbon steel nickel plated Specification 0782 200 (441) 300 (661) 2 ± 0.1% ≤ 0.05 ≤ 0.06 ≤ 0.002 (0.001) ≤ 0.002 (0.001) -10 ~ +40 (+14 ~ +104) -30 ~ +65 (-22 ~ + 150) -40 ~ +80 (-40 ~ + 176) II 2 GD EEx ib IIC T4-T6 IP68 T60°C II 3 GD EEx nL IIC T6 T60°C IP68 II 3 GD EEx nA II T6 T60°C IP68 Ui=20V, Ii=600mA, Pi=1.25W, Ci=9nF, Li=65µH IS II, 11,111/11 ABCDEFG I T4 NI/I,II,111/21 ABCDFG I T4 3013511 3028342C 5 ~ 15 20 1160 ± 15 1000 ± 3 stainless steel 4340 welded IP 68 NEMA 6/6P 125 300 0.32 (0.013) 3.42 (0.017) 12.5 (27.6) 21.7 (48) 20 (66) 30 (98) 5.8 (0.23) Error due to the combined effect of non-linearity and hysteresis Typical values only. The sum of errors due to Combined Error and Temperature Effect on Sensitivity comply with the requirements of OIML R60 and NIST HB44. 3) A.L. = Applied Load 4) See certificate for complete information. 5) % of Applied Load (A.L.) per mm (in) displacement of the top plate (transverse & longitudinal). 6) Maximum vertical downward force that can be applied to the top plate. 7) Horizontal restraint, down stop and anti-uplift protection must be provided externally for the 200t and 300t weigh modules. 1) 2) 2 METTLER TOLEDO ©01/2013 Data Sheet 3390 Weigh Modules H1 3390 Weigh Module Dimensions 200t–300t M12x1.75 (300t only) W2 W W1 H1 H 1) L1 L2 D(8x) L 1) Each weigh module is supplied with a shipping/installation plate to keep the top and bottom plates rigidly aligned during shipping and installation. Top Plate Travel Capacity 200t 441K lb 300t 661K lb D H H1 L L1 L2 W W1 W2 Longitudinal Transverse 24 355 40 220 17.5 185 180 22.5 135 ± 6 ±6 0.94 13.95 1.57 8.66 0.69 7.28 9.06 1.38 5.31 ± 0.24 ± 0.24 30 465 50 360 35 290 230 35 160 ± 6 ±6 1.18 18.31 1.97 14.17 1.38 11.42 9.06 1.38 6.30 ± 0.24 ± 0.24 METTLER TOLEDO Data Sheet 3390 Weigh Modules ©01/2013 3 3390 Weigh Module Ordering Information Description Weigh module (including load cell), model no. 3390 200t carbon steel Weigh module (including load cell), model no. 3390 300t carbon steel Weigh module (including load cell), model no. 3390 200t stainless steel Load cell, model no. 0782 200t (441klb) 20m (66ft) cable Load cell, model no. 0782 300t (661klb) 30m (98ft) cable Item No. 71210092 72197823 71210170 71210093 71210169 Bolded entries are stocked 3390 Cable Colors Colour Function Green + Excitation Black – Excitation White + Signal Red – Signal Yellow + Sense Blue – Sense Yellow (long) + Shield Full Connectivity METTLER TOLEDO supplies various data communication interfaces that enable our sensors and instruments to communicate with your PLC, MES, or ERP systems. Global Approvals Model 0782 load cells 100t used in 3390 Gagemount have global certifications for metrological performance and hazar­dous area applications. There is no need for options or additional charges. Weighing Electronics Our extensive service network is among the best in the world and ensures maximum availability and service life of your product. METTLER TOLEDO offers a complete family of electronics from simple weighing to application solutions for filling, stock control, batching, formulation, counting, and checkweighing. Quality certificate ISO 9001 Environment certificate ISO 14001 Subject to technical changes. © 01/2013 Mettler-Toledo AG Printed in Switzerland MTSI 44099866 MarCom Industrial www.mt.com Visit for more information