Low-Voltage Enclosure Low-voltage enclosures may be surface-mounted in an electrical closet or equipment room. Both the number of enclosures and the types of components within them are customized to fit the size, lighting plan, and design of a home. Low-voltage enclosures can be distributed throughout the home near the rooms they are controlling, to provide maximum flexibility during installation of the low-voltage wiring. Low-voltage enclosures cannot house remote power modules (RPMs). 14-inch Low-Voltage Enclosure The 14-inch low-voltage enclosure provides a compact housing for mounting one processor or one system interface and up to two wire landing boards (QS-WLB). The enclosure accepts one 120 V~ (HQ-LV14-120) or 220-240 V~ (L-LV14-230) feed to power the panel, which is self-contained in an enclosed area, thus allowing access to only the low-voltage connections when the enclosure cover is removed.
Low-Voltage Enclosure
Model Number HQ-LV14-120
120 V~ Low-Voltage Enclosure
L-LV14-230
220-240 V~ Low-Voltage Enclosure
Low-Voltage Enclosure Cover
www.lutron.com
1 | Lutron®
product specifications
369-604a
06.22.12
Low-Voltage Enclosure Specifications Model Numbers
HQ-LV14-120, L-LV14-230
Power
120 V~ 50/60 Hz 2 A, (HQ-LV14-120) 220-240 V~ 50 / 60 Hz 1 A (L-LV14-230)
Regulatory Approvals
UL, CSA CE, S C-tick (L-LV14-230)
Environment
Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C) Ambient operating humidity: 0-90% humidity, non-condensing. Indoor use only.
Mounting
Enclosure may be surface-mounted. Mount the enclosure so that line-voltage wiring will be at least 6 ft (1.8 m) from audio or electronic equipment and wiring. Mount Enclosure using the following method (mounting hardware is not provided): Surface Mount – Use keyholes with bolts sufficient for 100 lb (45 kg) load, 1/4 in (M6) bolts recommended. NOTICE: This equipment is air-cooled. Mount in a location where there is at least 12 in (305 mm) of clearance in front of the enclosure. NOTICE: Power supply will hum slightly and internal relays will click while in use. Mount in a location where such noise is acceptable.
Dimensions
Enclosure: 13.3 in (337 mm) x 9.2 in (235 mm) x 3.16 in (80 mm) Cover: 21.5 in (546 mm) x 15.386 in (391 mm)
Construction
Enclosure: 16-gauge powder coated sheet metal. Cover: 16-gauge powder coated metal cover. Cover is attached using four phillips-head screws.
Capacity
Enclosure can accommodate one processor or system interface device and two wire landing boards (QS-WLB).
Line-Voltage Connections
Use copper wire only, supply conductors rated at 167 ºF (75 °C). Use supplied wire connections to connect to corresponding power supply harnesses.
Warranty
http://www.lutron.com/technicaldocumentlibrary/homeworks_warranty.pdf
2 | Lutron®
Technical Support: U.S.A. 800.523.9466 Europe +44.(0)20.7680.4481
product specifications
369-604a
06.22.12
Low-Voltage Enclosure Mounting Front View
Side View Ceiling
Dedicated feed* Emergency feed** Line voltage only See Feed Requirements below
NEUTRAL
V+
COM
500-10561 Rev. B
V+
COM
MUX
MUX
MUX
D
HOT
5 4 3 2 1 D
MUX
5 4 3 2 1
L1
L2
Alternate IEC PELV/NECR Class 2 entry points
Wall
GROUND
Do not use these knockouts
Do not use these knockouts
24 V 2 A L1
1 2
L2
24 V 500 mA P
10/100
COM
PWR
10/100
3 4 5
Alternate IEC PELV/NECR Class 2 entry points
V+
COM
500-10561 Rev. B
MUX
MUX
V+
MUX
D
NEUTRAL
COM
L1
L2
HOT
5 4 3 2 1 D
5 4 3 2 1 MUX
Note: Follow NECR guidelines for minimum conduit bend radius.
GROUND
24 V 2 A L1
1 2
L2
24 V 500 mA P
10/100
COM
PWR
10/100
3 4 5
IEC PELV/NECR Class 2 wiring only for control links and Ethernet connection Note: An outlet must be installed within 6 ft (1.8 m) of the panel. Outlet should not be on the same circuit as the panel. Required for system start-up.
Feed Requirements *Lutron recommends using a dedicated circuit for lighting control devices. **Emergency feed is recommended so that the system status can be monitored during an emergency event. If this is not required, normal power can be used.
www.lutron.com
3 | Lutron®
product specifications
369-604a
06.22.12
Low-Voltage Enclosure Configuration Terminal Shield Processor or Interface (HQP6-2-120 shown)
Power Supply (QSPS-DH-1-60 shown) QS Wire Landing Board QS-WLB (up to 2)
4 | Lutron®