369-604a-eng

   EMBED


Share

Transcript

product specifications 369-604a 06.22.12 Low-Voltage Enclosure Low-voltage enclosures may be surface-mounted in an electrical closet or equipment room. Both the number of enclosures and the types of components within them are customized to fit the size, lighting plan, and design of a home. Low-voltage enclosures can be distributed throughout the home near the rooms they are controlling, to provide maximum flexibility during installation of the low-voltage wiring. Low-voltage enclosures cannot house remote power modules (RPMs). 14-inch Low-Voltage Enclosure The 14-inch low-voltage enclosure provides a compact housing for mounting one processor or one system interface and up to two wire landing boards (QS-WLB). The enclosure accepts one 120 V~ (HQ-LV14-120) or 220-240 V~ (L-LV14-230) feed to power the panel, which is self-contained in an enclosed area, thus allowing access to only the low-voltage connections when the enclosure cover is removed. Low-Voltage Enclosure Model Number HQ-LV14-120 120 V~ Low-Voltage Enclosure L-LV14-230 220-240 V~ Low-Voltage Enclosure Low-Voltage Enclosure Cover www.lutron.com 1 | Lutron® product specifications 369-604a 06.22.12 Low-Voltage Enclosure Specifications Model Numbers HQ-LV14-120, L-LV14-230 Power 120 V~ 50/60 Hz 2 A, (HQ-LV14-120) 220-240 V~ 50 / 60 Hz 1 A (L-LV14-230) Regulatory Approvals UL, CSA CE, S C-tick (L-LV14-230) Environment Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C) Ambient operating humidity: 0-90% humidity, non-condensing. Indoor use only. Mounting Enclosure may be surface-mounted. Mount the enclosure so that line-voltage wiring will be at least 6 ft (1.8 m) from audio or electronic equipment and wiring. Mount Enclosure using the following method (mounting hardware is not pro­vid­ed): Surface Mount – Use keyholes with bolts sufficient for 100 lb (45 kg) load, 1/4 in (M6) bolts rec­om­mend­ed. NOTICE: This equipment is air-cooled. Mount in a location where there is at least 12 in (305 mm) of clearance in front of the enclosure. NOTICE: Power supply will hum slightly and internal relays will click while in use. Mount in a location where such noise is acceptable. Dimensions Enclosure: 13.3 in (337 mm) x 9.2 in (235 mm) x 3.16 in (80 mm) Cover: 21.5 in (546 mm) x 15.386 in (391 mm) Construction Enclosure: 16-gauge powder coated sheet metal. Cover: 16-gauge powder coated metal cover. Cover is attached using four phillips-head screws. Capacity Enclosure can accommodate one processor or system interface device and two wire landing boards (QS-WLB). Line-Voltage Connections Use copper wire only, supply conductors rated at 167 ºF (75 °C). Use supplied wire connections to connect to corresponding power supply harnesses. Warranty http://www.lutron.com/technicaldocumentlibrary/homeworks_warranty.pdf 2 | Lutron® Technical Support: U.S.A. 800.523.9466 Europe +44.(0)20.7680.4481 product specifications 369-604a 06.22.12 Low-Voltage Enclosure Mounting Front View Side View Ceiling Dedicated feed* Emergency feed** Line voltage only See Feed Requirements below NEUTRAL V+ COM 500-10561 Rev. B V+ COM MUX MUX MUX D HOT 5 4 3 2 1 D MUX 5 4 3 2 1 L1 L2 Alternate IEC PELV/NECR Class 2 entry points Wall GROUND Do not use these knockouts Do not use these knockouts 24 V 2 A L1 1 2 L2 24 V 500 mA P 10/100 COM PWR 10/100 3 4 5 Alternate IEC PELV/NECR Class 2 entry points V+ COM 500-10561 Rev. B MUX MUX V+ MUX D NEUTRAL COM L1 L2 HOT 5 4 3 2 1 D 5 4 3 2 1 MUX Note: Follow NECR guidelines for minimum conduit bend radius. GROUND 24 V 2 A L1 1 2 L2 24 V 500 mA P 10/100 COM PWR 10/100 3 4 5 IEC PELV/NECR Class 2 wiring only for control links and Ethernet connection Note: An outlet must be installed within 6 ft (1.8 m) of the panel. Outlet should not be on the same circuit as the panel. Required for system start-up. Feed Requirements *Lutron recommends using a dedicated circuit for lighting control devices. **Emergency feed is recommended so that the system status can be monitored during an emergency event. If this is not required, normal power can be used. www.lutron.com 3 | Lutron® product specifications 369-604a 06.22.12 Low-Voltage Enclosure Configuration Terminal Shield Processor or Interface (HQP6-2-120 shown) Power Supply (QSPS-DH-1-60 shown) QS Wire Landing Board QS-WLB (up to 2) 4 | Lutron® Technical Support: U.S.A. 800.523.9466 Europe +44.(0)20.7680.4481