Preview only show first 10 pages with watermark. For full document please download

3.74 Mb

   EMBED


Share

Transcript

instruction manual MA2012 / 2006 60 / 120W 100V line mixer amplifier version 1/05 Thank you for choosing another quality product from Amperes Electronics. MA2006 / 2012 features 6 mic / line inputs with selectable input level, 3 zone speaker output with ALL CALL as well as phantom power for input 1 and 2. It has the required features for most PA installation such as priority override for channel 1 and 2, which can be disabled or the muting level adjusted for a proper mix. We believe that this product shall be able to meet your demanding requirement with affordable pricing and uncompromised features and quality. Though it is rather simple in the installation works, a brief read through the manual is recommended and we are confident that you are getting a product of excellence. www.ampereselectronics.com Parts Identifications 6 7 SPEAKER OUTPUT amperes 1 MA 2012 2 3 ALL CALL AUDIO LEVEL PWR PROT. MIC INPUT CH1 CH2 CH3 CH4 CH5 CH6 BASS TREBLE 0 dB POWER MASTER I O MIN MAX MIN MAX MIN MAX 1 MIN MAX MIN MAX MIN MAX MIN MAX 2 9 8 + 10 - MAX MIN 11 MAX 5 4 3 12 13 WARNING ! 100V LINE SPEAKER OUTPUT DC POWER 24V / 10A PRESS TO RESET BREAKER MAINS : 230/240V AC 50 / 60 Hz MIN COM 4OHM COM SP 1 SP 2 SP 3 REMOTE 1 MODEL : MA2012 2 3 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. 24VDC 0.5A A PR - + CAUTION POWER OUTPUT 120W RMS RISK OF ELECTRICAL SHOCK DO NOT OPEN DC 10A CH5 CH3 CH5 CH6 LINE OUT CH4 CH2 CH3 MUTE CH1 CH2 PHANTOM POWER CH1 PHANTOM POWER AC 5A MIC LINE MIC LINE 14 CH6 CH4 MIC LINE MIC LINE 15 16 17 18 1. Front Mic Input Jack Channel 1 balanced microphone input. Once inserted, it shall bypass the rear input connection. 2. Input Level Controls Individual control knobs for input 1 to 6. 3. Tone Controls Bass and treble controls for mixed signals. 4. Master Control Master volume control for mixed signal ; speaker and line outputs. 5. Power Switch Mains switch for ac input. Switching off the switch shall not disconnect the DC supply to the unit if it is connected to back up battery. It is recommended that the DC back up is connected to the battery charger's EM output instead of directly to the batteries. This shall prevent idle drain of the battery bank. 6. Speaker Zone Selector 100V line ouput can be channeled into 3 output zones and each zone can be selected via these switches with ALL CALL. Alternatively, selected can also be done via remote paging microphone, ie. PM1060. 7. LED Indicators LED indicators for Power, Protect mode and 4 segment output level meter. 8. Circuit Breakers Resettable circuit breakers for ac and dc inputs of 5 and 10A respectively. amperes PAGE 2 amperes electronics 9. 24V DC Power Input Input to battery bank for back up supply with 10A rating at full load. 10. Low Impedance Output For connections to speaker output with 4 Ohm min. This shall bypass the speaker zone selector. Ensure that the load does not exceed to power rating. 11. 100V Line Speaker Terminals Allows connection of speakers with matching transformer to the unit under 3 zones. Total load shall not exceed the specified rating of the power amplifier. 12. Line Output Line level output for connection to external link. The output level is controlled by the Master volume controller. 13. Remote Paging Zone Selection External control of speaker zone selection via negative triggering method. Connection to Amperes PM1060 is recommended. 14. Mic / Line Level Switch Inputs to the unit can be either mic or line level. Select the required input type by using these switches and plug the input source to the appropriate jack. Stereo phone jack for balanced mic input whereas the RCA jack is for music source unbalanced line input. It is recommended that at any one time, only one type of input source is connected to the amplifier. 15. RCA Jack For unbalanced line input sources such as CD player, etc. 16. Mute Level Control Input channel 1 and 2 has priority over other channels, such that the presence of the signal shall mute other input sources. The level of mute or mixing is controlled by this switch, which can fully or partially mute or normal mix. 17. XLR inputs 2 XLR balanced inputs are available for microphones. 18. Phantom Power Switch 12V DC phantom power is available for input channel 1 and 2, which is suitable for connection to condenser microphones. For normal mic inputs, it is recommended that the phantom power feature is turned off. PAGE 3 Application Example PAGING MIC (MIC IN) TUNER MA2012 MIXER AMP SPEAKER OUTPUT amperes 1 MA 2012 2 3 ALL CALL AUDIO LEVEL PWR PROT. 0 dB CD PLAYER CD PLAYER MIC INPUT CH1 CH2 CH3 CH4 CH5 CH6 BASS TREBLE POWER MASTER I O MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX CASSETTE HANDHELD MIC (MIC IN) AUX IN (MIC / LINE) ZONE 1 ZONE 3 ZONE 2 TO SPEAKER OUTPUT Note : 1. Paging microphone can be with or without zone selection. 2. Speaker output connected to speakers with matching transformer (100V line out ) or without transformer of 4 Ohm. Total output shall not exceed the specified rating. 3. Connection of input, select the appropriate input level. Rear Connections VOLUME CONTROLLER SPEAKERS WITH MATCHING TRANSFORMER ZONE 1 TO 3 balanced out speaker cable LOW BATT CHARGING / BATT VOLTAGE VOLT POWER CHARGING CURRENT AMPS amperes I O BACK UP BATT. E/M OUTPUT FROM BATTERY CHARGER REMOTE PAGING MIC (ZONE SELECTION OPTIONAL) 6 core cable AC MAINS CHARGING BATT VLTG BC 730 LINE OUT TO EXTERNAL LINK (NEXT AMPLIFIER) audio : 2c scr + - WARNING ! 100V LINE SPEAKER OUTPUT DC POWER 24V / 10A PRESS TO RESET BREAKER MAINS : 230/240V AC 50 / 60 Hz COM 4OHM COM SP 1 SP 2 SP 3 REMOTE 1 MODEL : MA2012 2 3 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. 24VDC 0.5A A PR - + CAUTION POWER OUTPUT 120W RMS RISK OF ELECTRICAL SHOCK DO NOT OPEN DC 10A CH5 CH3 CH6 CH4 CH5 CH6 LINE OUT CH4 CH2 CH3 MUTE CH1 CH2 PHANTOM POWER CH1 PHANTOM POWER AC 5A MIC LINE MIC LINE CD PLAYER CD PLAYER / CASSETTE DECK/ TUNER/ ETC MIC LINE MIC LINE mic cable line in - unbal. DYNAMIC / CONDENSER MIC FOR CH.1 OR 2 DYNAMIC MIC WITH PHONE JACK amperes PAGE 4 amperes electronics Connecting Paging Microphone External paging desk with or without zone selection can be connected to the unit, preferable with microphone level output. Connection can be done via the front panel 1/4" stereo phone jack or rear panel XLR jack. It is recommended that paging desk with zone selection (Amperes PM1060) be connected via the rear panel jack. The diagram below illustrates the connection of Amperes PM1060 paging desk with zone selection : AMPERES PM1060 PAGING DESK phone jack Connection : PM1060 Pin 1 Pin 2 Pin 3 Pin 13 Pin 14 Pin 15 Chassis 8C multi core flexible cable D15 connector WARNING ! REMOTE 1 2 3 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. 24VDC 0.5A + A PR CAUTION MA2012 Remote 1 Remote 2 Remote 3 Remote A Remote PR + ve - ve REAR OF MA2012 RISK OF ELECTRICAL SHOCK DO NOT OPEN CH2 LINE OUT MIC LINE CH1 MUTE CH3 CH2 PHANTOM POWER MIC CH1 PHANTOM POWER LINE set mute level accordingly 2 core screen XLR jack Input to channel 1 Switch off phantom power Connecting BGM Sources Use the right connector for the appropriate BGM source. At any one time, only one jack shall be connected to the inputs of the same channel to avoid interference. Also, please switch to the right input level position for the correspondence input source. 100V LINE SPEAKER OUTPUT COM CH5 SP 1 SP 2 SP 3 LINE OUT CH3 CH4 MIC LINE CH6 CH4 CH3 MIC LINE MIC Switch to the appropriate input level attenuator. ie. LINE for BGM source. Very often BGM source shall have stereo outputs whereas the mixer amp has only mono input. Therefore, use either output of the BGM source to connect to the input. To obtain better result of music STEREO PHONE JACK Balanced input source (Line / Mic level) RCA JACK PAGE 5 Phantom Power PHANTOM POWER SWITCH Switch on when condenser microphone is used. In normal usage, it is recommended that it is switched off Two channels - 1 and 2 are provided with switchable phantom power of 12V. REMOTE 1 2 3 24VDC 0.5A A PR - + CH2 MUTE CH1 CH1 PHANTOM POWER CH2 PHANTOM POWER LINE CH 1 and CH 2 are provided with phantom power Block Diagram LED LEVEL INDICATORS Inputs Ch 1,2 Phone/XLR LEVEL CTRL Inputs Ch 3 to 6 (Phone/RCA) MIXER CIRCUIT 12V Phantom Power 100V line speaker outputs zone 1 to 3 TONE CONTROL AMPLIFIER CIRCUIT FRONT ZONE SELECTOR CONNECTORS POWER SUPPLY CIRCUIT MAINS SW AC input 4 Ohm min output STEP UP TRANS FUSE 24V DC 12V DC 24V DC batt input Remote Zone Selection Inputs FAN CONTROL CIRCUIT THERMISTOR HEAT REGULATED FAN NOTE : Fan only available in MA2012 The above drawing illustrates general functional block diagram in the construction of the unit and may not represent the final actual circuit. It is not recommended that the above diagram to be used for servicing any faulty unit. Contact our service centre for any repair works. amperes PAGE 6 amperes electronics Connection of Jacks MIC/BALANCED INPUT XLR 2 1 MIXER BALANCED OUTPUT XLR 1 1 - GROUND / SCREEN 2 - HOT ( +VE ) 3 - COLD ( - ) 3 FOR UNBALANCED, CONNECT PIN 1 AND 3 TOGETHER 2 3 FOR UNBALANCED, SPARE PIN 3 TIP : +VE / HOT SIGNAL PHONE JACK RING : -VE / COLD SLEEVE : GROUND / SCREEN Summary of Features 2 mic and 4 mic / line selectable input channels, with front mic in jack 3 zone speaker outputs with ALL CALL Switchable phantom power for mic input 1 and 2 70 V line and 4 Ohm outputs Individual input level control with master out Tone controls for bass and treble Priority for mic input 1 with adjustable muting level AC/DC operation for fixed installation and mobility Technical Specifications Operating voltage Amplifier rating Power consumption Input channels Phantom power Sensitivity / impedance Freq. response (+/-3dB) S/N ratio (1 kHz) Tone controls Indicators Output Output select 230 / 240V ac : 50/60 Hz MA2012 (120W) : MA2006 (60W rms) MA2012 (2.2A) : MA2006 (1.2A) at 240V full load 2 mic, 4 mic/line selectable 12V DC, switchable Mic - 2.45 mV / 2 K Ohm balanced Line - 245 mV / 30 K Ohm balanced RCA line - 495 mV unbalanced 60 ~ 18 kHz >75 dB Bass ( 100Hz ) : Treble ( 10 kHz ) +/-12 dB Power ; Protect ; Output level - 4 segment 3 zones 100V line ; 4 Ohm Front switch and remote triggering Protections Cooling system Thermal, Circuit breaker MA2012 (fan forced) : MA2060 (convection) Dimensions Weight 424 (W) x 44 (H) x 300 (D) mm MA2012 (12.5 kg) : MA2060 (9.4 kg) PAGE 7 WARRANTY CONDITIONS Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes Electronics Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn Bhd at 70 Jalan Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor, Malaysia. It may also be sent to its master distributor in the country the product is purchased. This warranty is not valid if repairs are performed by unauthorized personnel or service centres. This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as well as removal and installation of the product from the main system are for the account of the purchaser. This warranty shall not extend to the replacement of the unit. This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using the product with power supply voltage other than shown on the product, or any other power supply source / adaptor not recommended by the manufacturer. This warranty does not cover damages caused by fire, earthquakes, floods. lightning and every cause not directly related to the unit. This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use of the unit; moreover the warranty does not cover any damages which may be caused to people and things when using the product. This warranty certificate is valid only for the described product, and is not valid if modifications are made on this certificate or on the identification label applied on the product. This warranty covers all the material and manufacturing defects and is valid for a period of 12 months from the date of purchase or for a longer period in countries where this is stated by a national law. In this case, the extension is valid only in the country where the product is purchased. Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if the design changes or improvements are made. DISCLAIMER Information contained in this manual is subject to change without prior notice and does not represent a commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any loss or damages whatsoever arising from the use of information or any error contained in this manual. It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS SDN BHD or its authorized service agents. AMPERES series must only be used for the purpose they were intended by the manufacturer and in conjunction with this operating manual. AMPERES ELECTRONICS SDN BHD or its distributors cannot accept any liability whatsoever for any loss or damages caused by service, maintenance or repair by unauthorized personnel, or by use other than that intended by the manufacturer. amperes PAGE 8 By : AMPERES ELECTRONICS www.ampereselectronics.com Made In Malaysia