38tkw Air Conditioning Unit Wiring Diagrams

   EMBED


Share

Transcript

38TKW Air Conditioning Unit Wiring Diagrams CONNECTION DIAGRAM (NOTE #9) *CH RED or BLK BLK *DSV RED or BLK BLK COMP BLU S C H BLK L1 208/230 1Ø POWER SUPPLY BLK 11 23 L2 21 23 CONT EQUIP GND R C YEL F BLU CAP *DSV L1 +t YEL YEL BRN *ST CONT 1 2 *SC 5 (NOTE #8) *SR BRN OFM BLK EQUIP GND 5 2 H *SR CONT OFM C F VIO BLK *LPS YEL BLK T2 YEL *HPS *LPS *DTS C R LOGIC T1 *LLS EXTERNAL POWER SUPPLY 24 V G Y IFR R R R INDOOR THERMOSTAT (NOTE #6) INDOOR THERMOSTAT INDOOR BLOWER MOTOR WARNING Service valve gauge port may not be equipped with Schrader valve (valve core). To prevent personal injury, make sure valve stem is back-seated (counterclockwise) before removing cap. Wear safety glasses and gloves when handling refrigerant. CAUTION 1. Compressor damage may occur if system is over charged. 2. This unit is factory charged with R-22 in accordance with the amount shown on the rating plate. The charge is adequate for most systems using matched coils and tubing not over 15 feet long. The best performance will be achieved when the unit operates with a suction gas superheat at the compressor inlet of 5 °F at normal rating conditions of the air conditioning and refrigeration institute (ARI). This chart may be used to approximate the charge if ARI rating conditions cannot be obtained. ARI rating conditions are equivalent to DOE test "A" conditions. See product data literature for required indoor air flow rates and for use of line lengths over 15 Ft. 3. Carefully relieve refrigerant pressure within this unit before final disposal. -LEGENDFACTORY POWER WIRING *CH CRANKCASE HEATER OFM OUTDOOR FAN MOTOR FIELD POWER WIRING COMP COMPRESSOR *SC START CAPACITOR FACTORY CONTROL WIRING *CTD COMPRESSOR TIME DELAY FIELD CONTROL WIRING *DSV DISCH. SOLENOID VALVE COMPONENT CONNECTION *DTS DISCHARGE TEMP. SWITCH FIELD SPLICE *HPS HIGH PRESSURE SWITCH JUNCTION IFR INDOOR FAN RELAY CONT CONTACTOR *LLS LIQ. LINE SOLENOID VALVE CAP CAPACITOR (DUAL RUN) *LPS LOW PRESSURE SWITCH T3 * CTD G (NOTE #3) Y 23 T2 BRN IFR 23 CONT T3 *LLS BLK CAP (NOTE #14) LOGIC T1 L2 *ST +t *SC BLK *DTS BLK COMP S 1 *CH * CTD BLU BLU R C 21 11 YEL BLU (NOTE #14) BLU BLU BLU YEL BRN *HPS SCHEMATIC DIAGRAM (LADDER FORM) *SR START RELAY *ST START THERMISTOR * MAY BE FACTORY OR FIELD INSTALLED. C EXTERNAL POWER SUPPLY 24 V -NOTES1. Symbols are electrical representation only. 2. Compressor and fan motor furnished with inherent thermal protection. 3. To be wired in accordance with National Electric N.E.C. and local codes. 4. N.E.C. class 2, 24V circuit, min. 40 VA required, 60 VA on units installed with LLS. 5. Use copper conductors only. 6. Connection for typical cooling only thermostat. For other arrangements see installation instructions. 7. If indoor section has a transformer with a grounded secondary, connect the grounded side to the BRN lead. 8. When start relay and start capacitor are installed, start thermistor is not used. 9. CH not used on all units. 10. If any of the original wire, as supplied, must be replaced, use the same or equivalent wire. 11. Check all electrical connections inside control box for tightness. 12. Do not attempt to operate unit until service valves have been opened. 13. Do not rapid cycle compressor. Compressor must be off 3 minutes to allow pressures to equalize between high and low side before starting. 14. Wire not present if HPS, LPS, DTS or CTD are used. 15. Use conductors suitable for at least 75°C (167°F). 320918-401 REV. D A96166 Fig. 1—38TKW018-048 208-230v, 1 Phase, 60 Hertz Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 563-941 Printed in U.S.A. Form 38TKW-1W Pg 1 4-96 Replaces: New Tab 3a 2a CONNECTION DIAGRAM SCHEMATIC DIAGRAM (LADDER FORM) (NOTE #9) *CH RED or BLK RED or BLK BLK L1 208/230 1Ø POWER SUPPLY COMP BLU S H BLK BLK 11 13 L2 21 23 CONT EQUIP GND R C YEL F YEL BLK +t YEL *ST BRN *SC (NOTE #8) 1 COMP R CONT 2 EQUIP GND 5 *SR C L2 21 11 5 S 2 *ST +t *SC 1 *CH H *SR CONT OFM YEL C F BRN (NOTE #14) T2 BLK BLK YEL YEL CONT LOGIC *HPS T3 *DTS *LPS T2 * CTD LOGIC T1 BRN *LLS *LLS BLK BLK C R IFR EXTERNAL POWER SUPPLY 24 V G Y IFR R INDOOR THERMOSTAT R INDOOR THERMOSTAT (NOTE #6) WARNING CAUTION 1. Compressor damage may occur if system is over charged. 2. This unit is factory charged with R-22 in accordance with the amount shown on the rating plate. The charge is adequate for most systems using matched coils and tubing not over 15 feet long. The best performance will be achieved when the unit operates with a suction gas superheat at the compressor inlet of 5 °F at normal rating conditions of the air conditioning and refrigeration institute (ARI). This chart may be used to approximate the charge if ARI rating conditions cannot be obtained. ARI rating conditions are equivalent to DOE test "A" conditions. See product data literature for required indoor air flow rates and for use of line lengths over 15 Ft. 3. Carefully relieve refrigerant pressure within this unit before final disposal. -LEGENDFIELD POWER WIRING FACTORY CONTROL WIRING FIELD CONTROL WIRING COMPONENT CONNECTION FIELD SPLICE JUNCTION R C EXTERNAL POWER SUPPLY 24 V INDOOR BLOWER MOTOR Service valve gauge port may not be equipped with Schrader valve (valve core). To prevent personal injury, make sure valve stem is back-seated (counterclockwise) before removing cap. Wear safety glasses and gloves when handling refrigerant. FACTORY POWER WIRING T3 CTD G (NOTE #3) Y 13 VIO *LPS T1 BLU BLU CAP 23 BLK *DTS BLU BLU YEL BRN OFM BLU (NOTE #14) *HPS BLU BLU CAP C *DSV L1 BLK *DSV CONT CONTACTOR *LLS CAP CAPACITOR (DUAL RUN) *LPS LOW PRESSURE SWITCH *CH CRANKCASE HEATER OFM OUTDOOR FAN MOTOR COMP COMPRESSOR *SC START CAPACITOR *CTD COMPRESSOR TIME DELAY *DSV DISCH. SOLENOID VALVE *DTS DISCHARGE TEMP. SWITCH *HPS HIGH PRESSURE SWITCH IFR INDOOR FAN RELAY LIQ. LINE SOLENOID VALVE *SR START RELAY *ST START THERMISTOR * MAY BE FACTORY OR FIELD INSTALLED. 320929-401 REV. D -NOTES1. Symbols are electrical representation only. 2. Compressor and fan motor furnished with inherent thermal protection. 3. To be wired in accordance with National Electric N.E.C. and local codes. 4. N.E.C. class 2, 24V circuit, min. 40 VA required, 60 VA on units installed with LLS. 5. Use copper conductors only. 6. Connection for typical cooling only thermostat. For other arrangements see installation instructions. 7. If indoor section has a transformer with a grounded secondary, connect the grounded side to the BRN lead. 8. When start relay and start capacitor are installed, start thermistor is not used. 9. CH not used on all units. 10. If any of the original wire, as supplied must be replaced, use the same or equivalent wire. 11. Check all electrical connections inside control box for tightness. 12. Do not attempt to operate unit until service valves have been opened. 13. Do not rapid cycle compressor. Compressor must be off 3 minutes to allow pressures to equalize between high and low side before starting. 14. Wire not present if HPS, LPS, DTS or CTD are used. 15. Use conductors suitable for at least 75°C (167°F). A96167 Fig. 2—38TKW060 208-230v, 1 Phase, 60 Hertz Copyright 1996 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 38tkw1w Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 563-941 Printed in U.S.A. Form 38TKW-1W Pg 2 4-96 Replaces: New Tab 3a 2a