Transcript
CAM940/CAM940E Passive Infrared Detector with High Resolution Black & White Video Output Installation Instructions 1.0
Description
The CAM940 and CAM940E provide high resolution Black & White CCD cameras and high performance PIR motion sensors using advanced signal processing to provide outstanding catch performance and unsurpassed false alarm immunity. Their Passive Infrared (PIR) motion sensors are designed to detect movement in the interior of a structure by sensing the Infrared energy emitted from the human body as it moves across the sensor’s field of view. When motion is detected, the Detector sends an alarm signal to the Control Panel with a Form “A” (NC) set of contacts. An auxiliary Form “C” (NC, C, NO) contact set is available for turning on auxiliary devices, such as VCRs.
2.0
Specifications
• Input Power: • Current Draw: • Standby Power:
• PIR Coverage: • Relays:
• Temperature:
• Humidity:
• Dimensions (HxWxD):
9-15 VDC 30 mA @ 12 VDC Standby, 120 mA in Alarm or with camera on No internal standby battery. Connect to DC power source capable of supplying standby power. Four hours (120 mAh) are required for UL Listed installations. 40 ft. x 40 ft. (12 m x 12 m) One Form “A” Normally Closed (NC) contact set and one Form “C” (NC, C, NO) contact set rated for 125 mA @ 12 volts maximum DC or AC for resistive loads. +14°F to +120°F (-10°C to +49°C). For UL Listed Installations, the temperature range is +32°F to +120°F (0°C to +49°C). 0 - 85% non-condensing.
3.0
Installation
3.1
Remove the cover using a small flat-blade screwdriver.
• Mounting:
Camera Specifications: • S/N Ratio: • Sensitivity: • Scanning System: • Video Signal: • • • • •
Field of View: Horizontal Resolution: Image Device: Electronic Shutter: Lens:
3.2
Press the latching tab toward the side of the case and lift out the board.
3.4
Avoid
3.75 in. x 2.25 in. x 1.5 in. (9.5 cm x 5.7 cm x 3.8 cm) B335 Swivel Bracket (included); B338 Ceiling Bracket (optional).
>45 dB 2.5 Lux 2:1 interlaced CAM940: NTSC 75Ω CAM940E: PAL 75Ω 75° 380 TV lines 1/3-inch Black & White CCD 1/60-1/100,000 second 3.6 mm fixed focal length
Bot tom of D etector
Insert screwdriver here or here
3.3
Select a mounting location
D ir ec t H o t o r C o ld D ra ft s
Mounting Outdoors 6.5 - 9 ft. (2 - 2.7 m)
A ir C o n d it io n in g O ut le ts
W in d o w s and U n in s u la te d W a lls
D ire c t S u n lig h t
M o v in g O b je cts
Heat Sources
Mount the detector 6.5 - 9 ft. (2 - 2.7 m) above the floor.
Pe ts
3.5
Mount the detector Thinwall for wiring
A. Remove
B. Attach the Adapter Plate to the back of the base.
Areas to mount the B335 Bracket
2 1
Knockout for Optional Cover Tamper Screw
Note: To avoid possible circuit board damage, use only the mounting hardware provided.
3.6
3.7
Wire the Detector
9-15 VDC
Use the supplied cable and connectors for the Video Output. Connect to 75 Ohm RG59/U or similar coax cable. Do not exceed 500 ft. (152 m). Aux Contacts to VCR or other devices. The Aux Contacts follow the Timer settings
- + -
+
Set the switches
SENS I/H LED OFF/ON TIMER ON/OFF 60/15 SEC
SENS I/H LED OFF/ON TIMER ON/OFF 60/15 SEC
SENS: OFF = Intermediate Sensitivity. ON = High Sensitivity.
ON (Closed)
OFF (Open)
LED: OFF = No LED. ON = LED on for alarms. TIMER: OFF = Camera on all the time. ON = Camera follows the 60/15 SEC timer. 60/15 SEC: If the TIMER switch is set to ON, the camera and Aux contacts will be on for a minimum of 60 seconds if the 60/15 switch is set to OFF. The camera/Aux contacts will be on for a minimum of 15 seconds if the 60/15 switch is set to ON. Any new motion will restart the timer and the camera/ Aux contacts will remain on.
Tamper Contacts
4.0
C. Attach the B335 (1) to the wall and attach the base (2) to the B335.
B335 Adapter Plate
Align the Detector with the camera on and the cover in place. The camera “sees” a higher area than the PIR sensor. Mounting the detector flat on the wall or pointing the detector too low will result in poor catch performance. Use the supplied bracket.
5.0
Walk Test the detector. Perform this test at the time of installation and monthly thereafter.
NO
Camera View PIR Pattern
OK 6.0
Coverage Patterns 0 Meters
20
NO
3
9
6
6
TOP VIEW
2
Although generally not required, if masking is desired the lens diagram shows the appropriate areas to be masked. Use an opaque material (such as electrical tape) to mask the desired areas.
12
3
PIR Camera
4
10
3
5 0 Meters
6
0
0
9
3
6
9
12 2.7
SIDE VIEW
2
6.5
7 10
3
10
9
8
0 6
20 0 Feet
10
20
30
1 2 3 4 5 6 7 8 9 1011
12 23 34 45 56 67
22 33 44 55 66 77
CAM940 Lens (inside view) Areas not used
0 0
Feet
10
20
30
40
40
© Bosch Security Systems, 130 Perinton Parkway, Fairport, New York, USA 14450-9199 (585) 223-4060 • (888) 289-0096 • Fax: (585) 223-9180 • Technical Support: (888) 886-6189
CAM940-CAM940E Installation Instructions P/N: 39168G 12/04 Page 2