12 Uninterruptible Power Systems Sola 4000 Series True On-Line Uninterruptible Power Systems (UPS) The true on-line (double conversion) protection offered by the Sola 4000 UPS series eliminates a wider range of potential power problems (spikes, surges and extended overvoltage, noise and other transients, sags and extended brownouts) even difficult-to-track harmonics and dangerous frequency variations that are common with standby generator operation. The Sola 4000 UPS modules are a true on-line design with a sine wave output. Each unit comes with a detachable, 6-foot input cord. CE listed for 230 Volt models. Plug & Receptacle Reference Chart Features • Input and output noise suppression. • Input power factor correction. • Two step battery recharge. • PWM inverter. • Battery fuses. • External battery packs available. • Integral sealed, non-spillable, user replaceable battery. • Two speed fan. • Automatic restart. • Automatic and manual battery test. • Microprocessor-based control and feature with push button and indicator monitoring package. Note: The securing flanges do not support the weight of the UPS. Rack slides or shelves are required (sold separately). 5-15P 5-15R 6-15P 5-20P 5-20R L6-15R L5-30P L5-30R IEC 320-10 C • RS232 communication port. • Input/Output voltage selector switch: 120 VAC models – (100, 110, 120, 127). 208 & 230 VAC models – (208, 220, 230, 240). • Integral dynamic bypass. • Compatible with standby generator operation. • Two-year warranty with optional extensions to five years. • $25,000 UPS Power Protection Promise. The LED display indicates annunciation of battery capacity, percentage of UPS load, battery operation, bypass operation and UPS fault condition. The rack-tower models are also supplied with securing flanges and rack slide mounting hardware. Selection Tables 120 VAC, 50/60 Hz Models Capacity (VA/W) Catalog Number Typical Runtime (minutes)* Input Plug/ Output Receptacle Approx. Ship Weight lbs (kg) Mini-Tow er Unit 700/490 S 4700 8/19 5-15P/ (4)5-15R 29.9 (13.6) 1000/700 S 41000 6/17 5-15P/ (4)5-15R 35.4 (16.1) 1000/700 S41000TRM 7/18 5-15P/ (8)5-15R 56.3 (25.6) 1500/1050 S41500TRM 7/15 5-15P/ (8)5-15R 62.9 (28.6) 2000/1400 S42000TRM 10/26 5-20P/ (6)5-15R & (2)5-20R 85.4 (38.8) 3000/2100 S43000TRM 6/15 L5-30P/ (6)5-15R & (1)L5-30R 89.8 (40.8) Rack-Tow er Unit *Full/Half Load (in minutes). 170 Fax-on-Demand #: (877) 888-9329, Document #: 8374 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 12 Uninterruptible Power Systems 208 VAC, 50/60 Hz Models (200/220/230/240 Input, 240 Volt Output settings allow for 10% additional VA capability). Capacity (VA/W) Catalog Number Typical Runtime (minutes)* Input Plug/ Output Receptacle Approx. Ship Weight lbs (kg) 1800/1260 S41800-208TRM 8/23 L6-15P/ (2)L6-15R 88 (40.0) 2700/1890 S42700-208TRM 6/17 L6-20P/(2)L6-15R & (1)L6-20R 93 (42.3) Typical Runtime (minutes)* Input Plug/ Output Receptacle Approx. Ship Weight lbs (kg) *Full/Half Load (in minutes). 230 VAC, 50/60 Hz Models Capacity (VA/W) Catalog Number Mini-Tow er Unit 700/490 S4700-5 8/19 (4)IEC320-10A 29.9 (13.6) 1000/700 S41000-5 6/17 (4)IEC320-10A 35.4 (16.1) 1000/700 S41000TRM-5 6/17 (4)IEC320-10A 56.3 (25.6) 1500/1050 S41500TRM-5 6/20 (4)IEC320-10A 62.9 (28.6) 2000/1400 S42000TRM-5 8/23 (4)IEC320-10A 85.4 (38.8) 3000/2100 S43000TRM-5 6/17 (4)IEC320-10A; (1)IEC320-16A 89.8 (40.8) Rack-Tow er Unit *Full/Half Load (in minutes). 6 and 10 KVA, 50/60 Hz, Hardwired Tower Models Capacity (VA/W) 6000/4200 10000/7000 5400/3780 9000/6300 6000/4200 10000/7000 Catalog Number S 460002 S 410000 2 S46000-208 3 S410000-208 S46000-240 3 Input Output Approx. Ship Weight lbs (kg) 7/15 2 0 8 4, 2 2 0 , 2 3 0 , 2 4 0 2084, 220, 230, 240 ±3% 288 (130) 4 208 , 220, 230, 240 208 , 220, 230, 240 ±3% 500 (277) 7/15 208 208/120 ±7% 381 (183) 7/15 3 4 10/22 10/22 3 S410000-240 Typical Runtime (minutes)1 208 4 208 , 220, 230, 240 4 208/120 ±7% 633 (287) 4 208 /104, 220/110, 230/115, 240/120 ±7% 374 (170) 4 10/22 208 , 220, 230, 240 208 /104, 220/110, 230/115, 240/120 ±7% 626 (284) 7/15 2 0 8 4, 2 2 0 , 2 3 0 , 2 4 0 2084/220/230/240 ±3% 288 (130) CE Marked Units 6000/4200 10000/7000 6000/4200 10000/7000 S46000-52 S410000-5 2 10/22 3 S46000-5-ISO 7/15 3 S410000-5-ISO 10/22 4 208 , 220, 230, 240 4 208 , 220, 230, 240 208, 220, 230, 240 4 500 (277) 4 374 (170) 4 626 (284) 208 /220/230/240 ±3% 208 /220/230/240 ±7% 208 /220/230/240 ±7% Notes: 1. Full/Half Load (in minutes). 2. Units come without the isolation transformer. 3. Output isolation transformer. 4. Derate 10% for 208V output setting. Fax-on-Demand #: (877) 888-9329, Document #: 8374 Contact Technical Services at (800) 377-4384 with any questions. 171 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 12 Uninterruptible Power Systems Hardware for Rackmount (Order Part Number Separately) Catalog Number Description Approx. Ship Weight lbs (kg) Wall Mount Bracket Kit 4100WB All Rack-Tower Models 13 (5.9) Rack Slide Kits 4300RH Rack slide kit for racks with 18-24” deep support rails. 7 (3.2) 4400RH Rack slide kit for racks with 24-32” deep support rails. 8 (3.6) Intellislot™ SNMP (Simple Network Management Protocol) Network Interface Kit Provides internal hardware and software to communicate to any Ethernet network. Ethernet connection is made via UTP (unshielded twisted pair) cable provided by customer. The SNMP kit includes the SNMP hardware, the MIB, configuration cable, and installation manual. Telecom/Relay Rack Shelves 4500RH Flush-mount shelf for 19” wide telecom/relay rack 17 (7.7) 4600RH Center-mount shelf for 19” wide telecom/relay rack 19 (8.6) 4700RH Flush-mount shelf for 24” wide telecom/relay rack 21 (9.5) 4800RH Center-mount shelf for 24” wide telecom/relay rack 22 (10.0) Description Approx. Ship Weight lbs (kg) Ethernet SNMP Kit with MIB & configuration cable 1 (.454) AS400 with two form C, dry contact relays 1 (.454) Catalog Number IntellislotTM Communications Option SNMPE3 SAS400CARD-T Note: Mounting equipment can be used for both the UPS and battery. Power A/C Distribution (PAD) and Associate Receptacles/Line Cord Options for the 4000 Series PADs provide output distribution receptacle, input connection and a rotary maintenance bypass switch. The PAD is field installed by the customer. Use of the PAD allows the UPS to be removed without interrupting power to the load. C atalo g N u mb er D escrip tio n C atalo g N u mb er D escrip tio n AD115A 120 Volt, 5-15P Line Cord/ (8) 5-15R AD130C 120 Volt, L5-30P Line Cord, (6) 5-15R, (2) 5-20R AD115B 120 Volt, 5-15P Line Cord/ (6) 5-15R, (2) L5-15R AD130E 120 Volt, L5-30P Line Cord, (6) 5-15R, (1) L5-30R 120 Volt, Hardwired for use with 15 Amp Input AD130H 120 Volt, 5-20P Line Cord, (6) 5-15R, (2) 5-20R AD115HW AD120A 120 Volt, 5-20P Line Cord/ (8) 5-15R AD130HW 120 Volt, Hardwired for use with 20 amp input AD120B 120 Volt, 5-20P Line Cord/ (6) 5-15R, (2) L5-15R AD215HW 230 Volt, Hardwired for use with 15 Amp Input AD120C 120 Volt, 5-20P Line Cord/ (6) 5-15R, (2) 5-20R AD220K 230 Volt, 50 Hz, IEC 320-10A Line Cord, (4) IEC 320-10 Receptacles AD120D 120 Volt, 5-20P Line Cord/ (6) 5-15R, (1) L5-20R AD220L 230 Volt, 50 Hz, IEC 320-16A Line Cord, (4) IEC 320-10A, (1) IEC-320-16A Receptacles 120 Volt, Hardwired for use with 20 amp input AD220M 208 Volt, L6-20P Line Cord, (2) L6-15R, (1) L6-20R Receptacles AD130A 120 Volt, L5-30P Line Cord/ (8) 5-15R AD220N 208 Volt, L6-20P Line Cord, (1) L6-20R, (1) L6-30R Receptacles AD130B 120 Volt, L5-30P Line Cord, (6) 5-15R, (2) L5-15R AD120HW AD220HW 208 Volt, Hardwired for use with 20 Amp Input Note: PADs can only be used with units having matching receptacles for the line cords provided. 172 Fax-on-Demand #: (877) 888-9329, Document #: 8374 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 12 Uninterruptible Power Systems External Battery Cabinets – For Tower/Rackmount UPS Models Only External battery cabinets are designed to provide the 1000 VA, 1500 VA, 2000 VA and 3000 VA tower/rackmount models with extended run time. Battery cabinets contain the interconnecting cable for attachment to the UPS. Refer to page 204 for Extended Warranty information. C atalo g N u mb er Typ ical R u n time (min u tes)* B attery C ab in et (Qu an tity) B attery C ab in et C atalo g N u mb er A p p ro x . S h ip Weig h t lb s (kg ) 7/18 Internal N/A - (-) 36/86 One 1436BAC 61 (27.7) 60/168 Two 1436BAC 122 (55.4) 7/15 Internal N/A - (-) 30/75 One 1448BAC 71 (32.3) 57/139 Two 1448BAC 142 (64.6) 10/26 Internal N/A - (-) 31/77 One 1496BAC 71 (32.3) 51/120 Two 1496BAC 142 (64.6) 120/240 One 2496BAC 450 (204.7) 6/15 Internal N/A - (-) 18/44 One 1496BAC 71 (32.3) 31/75 Two 1496BAC 142 (64.6) 90/180 One 2496BAC 450 (204.7) 7/15 Internal N/A - (-) 37/88 One 14240BAC 353 (160) 60/140 Two 14240BAC 706 (320) 10/22 Internal N/A - (-) 60/164 One 24240BAC 871 (395) 125/335 Two 24240BAC 1742 (790) S41000TRM or S41000TRM-5 S41500TRM or S41500TRM-5 S42000TRM or S41800-208-TRM or S42000TRM-5 S43000TRM or S42700-208-TRM or S43000TRM-5 S46000 or S46000-208 or S46000-240 or S46000-5 or S46000-5-ISO S410000 or S410000-208 or S410000-240 or S410000-5 or S410000-5-ISO * Full/Half Load (in minutes). Note: Contact Technical Services for longer runtimes. Fax-on-Demand #: (877) 888-9329, Document #: 8374 Contact Technical Services at (800) 377-4384 with any questions. 173 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 12 Uninterruptible Power Systems Sola 4000 Battery Run Time1 Charts S4700 Models S4700-5 Models S41000TRM and S41000 Models2 S41000TRM-5 and S41000-5 Models2 S41500TRM Model S41500TRM-5 Model Notes: 1. Run times are at 25 oC, 77oF, with 100% capacity batteries and resistive loads. 2. 41000 and 41000-5 do not accept external batteries. 174 Fax-on-Demand #: (877) 888-9329, Document #: 8374 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Uninterruptible Power Systems 12 Sola 4000 Battery Run Time1 Charts - continued S41800-200TRM Model S42700-208-TRM Model S42000TRM Model S42000TRM-5 Model S43000TRM Model S43000TRM-5 Model Note: 1. Run times are at 25oC, 77oF, with 100% capacity batteries and resistive loads. Fax-on-Demand #: (877) 888-9329, Document #: 8374 Contact Technical Services at (800) 377-4384 with any questions. 175 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 12 Uninterruptible Power Systems Sola 4000, 120 VAC, 50/60 Hz Models Specifications Sola 4000, 230 VAC, 50/60 Hz Models Specifications C atalo g N u mb er S 4700 S 41000 C atalo g N u mb er S 4 7 0 0 -5 S 4 1 0 0 0 -5 C ap acity (VA/Watts) 700/490 1000/700 C ap acity (VA/Watts) 700/490 1000/700 D imen sio n s- in ch es (mm) D imen sio n s- in ch es (mm) U n it (H x W x D ) 6.4 x 15.6 x 8.9 (162.0 x 430.0 x 225.0) U n it (H x W x D ) 6.4 x 15.6 x 8.9 (162.0 x 430.0 x 225.0) S h ip p in g (H x W x D ) 11.0 x 19.75 x 14.25 (280.0 x 502.0 x 362.0) S h ip p in g (H x W x D ) 11.0 x 19.75 x 14.25 (280.0 x 502.0 x 362.0) Ap p ro x. S h ip p in g Weig h t - lb s (kg ) 33.0 (15.0) 39.0 (17.7) Ap p ro x. S h ip p in g Weig h t - lb s (kg ) In p u t AC P arameters Vo ltag e R an g e (typ ical) 29.9 (13.6) 35.4 (16.1) In p u t AC P arameters 120 VAC nominal; variable based upon output load Vo ltag e R an g e (typ ical) 230 VAC nominal; variable based upon output load 100% - 70% L o ad in g 80-83 VAC to 134-138 VAC 100% - 70% L o ad in g 160-163 VAC to 273-276 VAC 70% - 30% L o ad in g 70-73 VAC to 134-138 VAC 70% - 30% L o ad in g 140-143 VAC to 273-276 VAC 30% - 0% L o ad in g 60-62 VAC to 134-138 VAC 30% - 0% L o ad in g 120-122 VAC to 273-276 VAC F req u en cy In p u t C o n n ecto r 45-55 Hz or 55-65 auto sensing 6 ft. detached, with NEMA 5-15 plug F re q u e n c y Ou tp u t AC P arameters Vo ltag e (4) NEMA 5-15R F req u en cy 50 Hz or 60 Hz Wavefo rm U tility Mo d e Overlo ad Sine wave Vo ltag e B attery Qty x Vo ltag e x R atin g B ack-u p T ime 208/220/230/240 VAC; ±3% switch selectable R ecep tacles (4) IEC320-10A F re q u e n c y 50 Hz or 60 Hz Wavefo rm 200% for 8 cycles; 130% for 10 seconds with transfer to bypass U tility Mo d e Overlo ad B attery P arameters B attery Typ e IEC320-10A Ou tp u t AC P arameters 100, 110, 120, 127 VAC; ±3% switch selectable R ecep tacles 48.1-51.9 Hz or 57.6-62.4; auto sensi ng In p u t C o n n ecto r Si ne wave 200% for 8 cycles; 130% for 10 seconds wi th transfer to bypass B attery P arameters Valve-Regulated, nonspillable, lead acid (2) x 12 V x 7.0 or 7.2 AH (3) x 12 V x 7.0 or 7.2 AH See Battery Run Time Charts B attery Typ e B attery Qty x Vo ltag e x R atin g Valve-Regulated, nonspillable, lead acid (2) x 12 V x 7.0 or 7.2 AH B ack-u p T ime E n viro n men tal (3) x 12 V x 7.0 or 7.2 AH See Battery Run Time Charts E n viro n men tal Op eratin g Temp eratu re +32oF to +104oF (0oC to +40oC) Op eratin g Temp eratu re +32oF to +104oF (0oC to +40oC) S to rag e Temp eratu re +5 F to +122 F (-15 C to +50 C) S to rag e Temp eratu re +5oF to +122oF (-15oC to +50oC) R elative H u mid ity Op eratin g E levatio n o o o o 0% to 95%, non-condensing Up to 10,000 ft. (3000 m) at 104 oC (40oC) without derating R elative H u mid ity Op eratin g E levatio n 0% to 95%, non-condensi ng Up to 10,000 ft. (3000 m) at 104 oC (40oC) without derating S to rag e E levatio n 15.000m (50,000 ft.) maximum S to rag e E levatio n 15.000m (50,000 ft.) maximum Au d ib le N o ise Less than 45 dBA @ 1 meter Au d ib le N o ise Less than 45 dBA @ 1 meter Ag e n c y S a fe ty R F I/E MI Immu n ity 176 Ag e n c y UL 1778, c-UL Listed FCC Part 15, Subpart B, Class A IEEE 587, Category A S a fe ty R F I/E MI EN50091-1, TUV/GS listed, CE Low Voltage Directi ve compliant EN55022, Class B; CE EMC Directive compli ant Immu n ity IEEE 587, Category A Fax-on-Demand #: (877) 888-9329, Document #: 8375 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Uninterruptible Power Systems 12 Sola 4000, 120 VAC, 50/60 Hz Tower/Rackmount Models Specifications C atalo g N u mb er S 41000T R M S 41500T R M S 42000T R M S 43000T R M C ap acity (VA/Watts) 1000/700 1500/1050 2000/1400 3000/2100 D imen sio n s - in ch es (mm) U n it (H x W x D ) 7.0 x 19.3 x 16.9 (177 x 522.0 x 430.0) 7.0 x 19.3 x 16.9 (177 x 522.0 x 430.0) 7.0 x 19.3 x 16.9 (177 x 522.0 x 430.0) 7.0 x 19.3 x 16.9 (177 x 522.0 x 430.0) S h ip p in g (H x W x D ) 13.38 x 26.0 x 22.25 (340 x 660 x 565) 13.38 x 26.0 x 22.25 (340 x 660 x 565) 13.38 x 26.0 x 22.25 (340 x 660 x 565) 13.38 x 26.0 x 22.25 (340 x 660 x 565) 56.3 (25.6) 62.9 (28.6) 85.4 (38.8) 89.88 (40.8) Ap p ro x. S h ip p in g Weig h t - lb s (kg ) In p u t AC P arameters Vo ltag e R an g e (typ ical) 120 VAC nominal; variable based upon output load 100% - 70% L o ad in g 80-83 VAC to 134-138 VAC N/A 100% - 90% L o ad in g N/A 90-93 VAC to 134-138 VAC 90% - 70% L o ad in g N/A 80-83 VAC to 134-138VAC 70% - 30% L o ad in g 70-73 VAC to 134-138 VAC 30% - 0% L o ad in g 60-63 VAC to 134-138 VAC F req u en cy In p u t C o n n ecto r 48.1-51.9 Hz or 57.6-62.4; auto sensing 6 ft. detached, w/ NEMA 5-15 Plug 6 ft. detached, w/ NEMA 5-20 Plug 6 ft. detached, w/ NEMA L5-30 Plug Ou tp u t AC P arameters Vo ltag e R ecep tacles 100/110/120/127 VAC; ±3% switch selectable (6) NEMA 5-15R (2) NEMA 5-20R (8) NEMA 5-15R F req u en cy 50 Hz or 60 Hz Wavefo rm Sine wave U tility Mo d e Overlo ad (6) NEMA 5-15R (1) NEMA L5-30R 200% for 8 cycles; 130% for 10 seconds with transfer to bypass B attery P arameters B attery Typ e B a t t e ry Qty x Vo ltag e x R atin g B ack-u p T ime Valve-Regulated, nonspillable, lead acid (3) x 12 V x 7 or 7.2 AH (4) x 12 V x 7 or 7.2 AH (8) x 12 V x 6.5 or 7.0 AH See Battery Run Time Charts E n viro n men tal Op eratin g Temp eratu re S to rag e Temp eratu re R elative H u mid ity Op eratin g E levatio n +32oF to +104oF (0oC to +40oC) +5oF to +122 oF (-15oC to +50oC) 0% to 95%, non-condensing Up to 10,000 ft. (3000 m) at 104oC (40oC) without derating S to rag e E levatio n 15.000m (50,000 ft.) maximum Au d ib le N o ise Less than 45 dBA @ 1 meter Ag e n c y S a fe ty R F I/E MI Immu n ity UL 1778, c-UL Listed FCC Part 15, Subpart B, Class A IEEE 587 Category A Fax-on-Demand #: (877) 888-9329, Document #: 8375 Contact Technical Services at (800) 377-4384 with any questions. 177 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 12 Uninterruptible Power Systems Sola 4000, 208 and 230 VAC, 50/60 Hz Tower/Rackmount Models Specifications Catalog Number S41800-208TRM S42700-208TRM S41000TRM-5 S41500TRM-5 S42000TRM-5 S43000TRM-5 Capacity (VA/Watts) 1800/12901 2700/18902 1000/700 1500/1050 2000/1400 3000/2100 85.4 (38.8) 89.88 (40.8) Dimensions - inches (mm) 7.0 x 19.3 x 16.9 (177 x 522 x 430) Unit (H x W x D) 13.38 x 26.0 x 22.25 (340 x 660 x 565) Shipping (H x W x D) Approx. Shipping Weight - lbs (kg) 88.0 (40.0) 93.0 (42.3) 56.3 (25.6) 62.9 (28.6) Input AC Parameters Voltage Range (typical) 100% - 70% Loading 208 VAC nominal; (240 VAC switch selectable) variable based upon output load N/A 230 VAC nominal; variable based upon output load 160-163 VAC to 273-276 VAC N/A N/A 100% - 90% Loading 181-191 VAC to 275-285 VAC N/A 184-187 VAC to 273-276 VAC 90% - 70% Loading 154-164 VAC to 275-285 VAC N/A 160-163 VAC to 273-276 VAC 70% - 30% Loading 134-144 VAC to 275-285 VAC 140-143 VAC to 273-276 VAC 30% - 0% Loading 114-124 VAC to 275-285 VAC 120-122 VAC to 273-276 VAC Frequency Input Connector 48.1-51.9 Hz or 57.6-62.4; auto sensing 6 ft. detached, w/ NEMA L6-15 plug 6 ft. detached, w/ NEMA L6-20 plug IEC320-10A IEC320-16A Output AC Parameters Voltage Receptacles 208/220/230/240 VAC; ±3% switch selectable (2) NEMA L6-15R (2) NEMA L6-15R, (1) NEMA L6-20R (4) IEC320-10A (4) IEC320-10A Frequency 50 Hz or 60 Hz Waveform Sine wave Utility Mode Overload (4) IEC320-10A (4) IEC320-10A; (1) IEC320-16A 200% for 8 cycles; 130% for 10 seconds with transfer to bypass Battery Parameters Battery Type Battery Qty x Voltage x Rating Valve-Regulated, nonspillable, lead acid (8) x 12 V x 7 or 7.2 AH Batt. Mfg./ Part Number (3) x 12 V x 7 or 7.2 AH (4) x 12 V x 7 or 7.2 AH (8) x 12 V x 6.5 or 7.0 AH CSB GP1270F2 or Panasonic LC-R127R2CH1 Back-up Time See Battery Run Time Charts Recharge Time 5 hours to 95% capacity after full discharge into 100% load Environmental Operating Temperature +32oF to +104oF (0oC to +40oC) Storage Temperature +5oF to +122oF (-15oC to +50oC) Relative Humidity 0% to 95%, non-condensing Up to 10,000 ft. (3000 m) at 104o C (40oC) without derating Operating Elevation Storage Elevation 15.000m (50,000 ft.) maximum Audible Noise Less than 45 dBA @ 1 meter Agency Safety RFI/EMI Immunity UL 1778, c-UL Listed EN50091-1, TUV/GS listed, CE Low Voltage Directive compliant FCC Part 15, Subpart B, Class A EN55022, Class B; CE EMC Directive compliant IEEE 587 Category A IEC 801-2, Level 4 / IEC 801-3, Level 3 / IEC 801-4, Level 4 / IEC801-5, Level 3 1. For output settings, VA is set for 2 KVA. 2. For output settings, VA is set for 3 KVA. 178 Fax-on-Demand #: (877) 888-9329, Document #: 8375 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 12 Uninterruptible Power Systems Sola 4000, 6 and 10 KVA, 50/60 Hz, Tower Models Specifications C atalo g N u mb er S 46000 S 410000 S 4 6 0 0 0 -5 S 4 1 0 0 0 0 -5 S 46000-5-IS O S 410000-5-IS O C ap acity (VA/Watts) 6000/4200 10000/7000 6000/4200 10000/7000 6000/4200 10000/7000 D imen sio n s- in ch es (mm) U n it (H x W x D ) 31.5 x 10.3 x 22.0 (800 x 260 x 588) 38.0 x 13.4 x 25.3 (965 x 340 x 640) 31.5 x 10.3 x 22.0 (800 x 260 x 588) 38.0 x 13.4 x 25.3 (965 x 340 x 640) 31.5 x 10.3 x 22.0 (800 x 260 x 588) 38.0 x 13.4 x 25.3 (965 x 340 x 640) S h ip p in g (H x W x D ) 40.9 x 16.3 x 33.1 (1040 x 415 x 840) 47.2 x 20.5 x 32.7 (1200 x 520 x 830) 40.9 x 16.3 x 33.1 (1040 x 415 x 840) 47.2 x 20.5 x 32.7 (1200 x 520 x 830) 40.9 x 16.3 x 33.1 (1040 x 415 x 840) 47.2 x 20.5 x 32.7 (1200 x 520 x 830) 288 (130) 500 (227) 288 (130) 500 (227) 374 (170) 626 (284) Ap p ro x. S h ip p in g Weig h t - lb s (kg ) In p u t AC P arameters Vo ltag e R an g e (typ ical) 208 VAC nominal; variable based upon output load 240 VAC nominal; switch selectable 100% - 90% L o ad in g 230 VAC nominal; variable based upon output load 186 VAC to 280 VAC; ±5.0 VAC 90% - 70% L o ad in g 159 VAC to 280 VAC; ±5.0 VAC 70% - 30% L o ad in g 139 VAC to 280 VAC; ±5.0 VAC 30% - 0% L o ad in g 119 VAC to 280 VAC; ±5.0 VAC F req u en cy 46.6-52.4 Hz or 57.1-62.9; auto sensing In p u t C o n n ecto r Hardwired terminal block Ou tp u t AC P arameters Vo ltag e 2081/220/230/240 VAC; ±3% switch selectable R ecep tacles 208/220/230/240 VAC; ±7% switch selectable Hardwired terminal block F req u en cy 50 Hz or 60 Hz; auto sensing Wavefo rm Sine wave U tility Mo d e Overlo ad 200% for 8 cycles; 130% for 10 seconds with transfer to bypass B attery P arameters B attery Typ e B attery Qty x Vo ltag e x R atin g B ack-u p T ime Valve-Regulated, nonspillable, lead acid 20 x 12 V x 7.0 AH 40 x 12 V x 7.0 AH 20 x 12 V x 7.0 AH 40 x 12 V x 7.0 AH 20 x 12 V x 7.0 AH 40 x 12 V x 7.0 AH 7 min. minimum 10 min. minimum 7 min. minimum 10 min. minimum 7 min. minimum 10 min. minimum < 55 dBA @ 1 meter < 65 dBA @ 1 meter E n viro n men tal Op eratin g Temp eratu re +32oF to +104oF (0oC to +40oC) S to rag e Temp eratu re +5oF to +122oF (-15oC to +50oC) R elative H u mid ity 0% to 95%, non-condensing Op eratin g E levatio n Up to 10,000 ft. (3000 m) at 104oC (40oC) without derating S to rag e E levatio n Au d ib le N o ise 15.000m (50,000 ft.) maximum < 55 dBA @ 1 meter < 65 dBA @ 1 meter < 55 dBA @ 1 meter < 65 dBA @ 1 meter Ag e n c y S a fe ty R F I/E MI Immu n ity UL 1778, c-UL Listed, EN50091-1, TUV/GS listed, CE Low Voltage Directive compliant FCC Part 15, Subpart B, Class A, EN55022, Class B; CE EMC Directive compliant IEEE 587 Category A, IEC 801-2, Level 4 / IEC 801-3, Level 3 / IEC 801-4, Level 4 / IEC801-5, Level 3 1. Derated 10% for 208 output setting. Fax-on-Demand #: (877) 888-9329, Document #: 8375 Contact Technical Services at (800) 377-4384 with any questions. 179 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 12 Uninterruptible Power Systems Sola 4000, 6 and 10 KVA, 50/60 Hz, Tower Models with Output Isolation Transformer Specifications C atalo g N u mb er S 4 6 0 0 0 -2 4 0 S 4 1 0 0 0 0 -2 4 0 S 4 6 0 0 0 -2 0 8 S 4 1 0 0 0 0 -2 0 8 C ap acity (VA/Watts) 6000/4200 10000/7000 5400/3780 9000/6300 D imen sio n s- in ch es (mm) U n it (H x W x D ) 31.5 x 10.3 x 22.0 (800 x 260 x 588) 38.0 x 13.4 x 25.3 (965 x 340 x 640) 31.5 x 10.3 x 22.0 (800 x 260 x 588) 38.0 x 13.4 x 25.3 (965 x 340 x 640) S h ip p in g (H x W x D ) 40.9 x 16.3 x 33.1 (1040 x 415 x 840) 47.2 x 20.5 x 32.7 (1200 x 520 x 830) 40.9 x 16.3 x 33.1 (1040 x 415 x 840) 47.2 x 20.5 x 32.7 (1200 x 520 x 830) 374 (170) 626 (284) 381 (173) 633 (287) Ap p ro x. S h ip p in g Weig h t - lb s (kg ) In p u t AC P arameters Vo ltag e R an g e (typ ical) 240 VAC nominal (208 VAC switch selectable); variable based upon output load 208 VAC nominal; variable based upon output load 100% - 90% L o ad in g 186 VAC to 280 VAC; ±5.0 VAC 90% - 70% L o ad in g 159 VAC to 280 VAC; ±5.0 VAC 70% - 30% L o ad in g 139 VAC to 280 VAC; ±5.0 VAC 30% - 0% L o ad in g 119 VAC to 280 VAC; ±5.0 VAC F req u en cy 46.6-52.4 Hz or 57.1-62.9; auto sensing In p u t C o n n ecto r Hardwired terminal block Ou tp u t AC P arameters Vo ltag e 208/1041, 220/110, 230/115, 240/120 VAC; ±7% switch selectable R ecep tacles 208/120 VAC; ±7% Hardwired terminal block F re q u e n c y 50 Hz or 60 Hz; auto sensing Wavefo rm Sine wave U tility Mo d e Overlo ad 200% for 8 cycles; 130% for 10 seconds with transfer to bypass B attery P arameters B attery Typ e B attery Qty x Vo ltag e x R atin g B ack-u p T ime Valve-Regulated, nonspillable, lead acid 20 x 12 V x 7.0 AH 40 x 12 V x 7.0 AH 20 x 12 V x 7.0 AH 40 x 12 V x 7.0 AH 7 min. minimum 10 min. minimum 7 min. minimum 10 min. minimum E n viro n men tal Op eratin g Temp eratu re +32oF to +104oF (0oC to +40oC) S to rag e Temp eratu re +5oF to +122oF (-15oC to +50oC) R elative H u mid ity 0% to 95%, non-condensing Up to 10,000 ft. (3000 m) at 104 oC (40oC) without derating Op eratin g E levatio n S to rag e E levatio n Au d ib le N o ise 15.000m (50,000 ft.) maximum < 55 dBA @ 1 meter < 65 dBA @ 1 meter < 55 dBA @ 1 meter < 65 dBA @ 1 meter Ag e n c y S a fe ty R F I/E MI Immu n ity UL 1778; Listed FCC Part 15 Class A IEEE C62.41:199 1. Derated 10% for 208 output setting. 180 Fax-on-Demand #: (877) 888-9329, Document #: 8375 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 12 Uninterruptible Power Systems External Battery Cabinets Specifications C atalo g N u mb er U sed w ith U P S Mo d el 1 4 3 6 B AC S41000TRM 1 4 4 8 B AC 1 4 9 6 B AC 2 4 9 6 B AC 1 4 2 4 0 B AC 2 4 2 4 0 B AC S41500TRM S42000TRM/ S4300TRM S42000TRM/ S4300TRM S46000 S410000 7.0 x 19.3 x 16.9 (177 x 522 x 430) 29.0 x 15.0 x 27.0 (737 x 381 x 686) 31.6 x 10.2 x 24.1 (803 x 260 x 612) 38.0 x 15.0 x 28.6 (965 x 380 x 726) 13.38 x 26.0 x 22.25 (340 x 660 x 565) 33.0 x 21.0 x 33.0 (838.2 x 533 x 838.2) 42 x 15.8 x 33.5 (106.3 x 400 x 850) 48.7 x 22.1 x 33.5 (1235 x 560 x 850) 600 (272) 353 (160) 871 (395) (4) x 12 V x 20 or 40 AH (3) x 12 V x 20 or 7.2 AH 42 hours to 90% capacity after full discharge into 100% load 16 hours to 90% capacity after full discharge into 100% load D imen sio n s - in ch es (mm) U n it (H x W x D ) S h ip p in g (H x W x D ) Ap p ro x. S h ip p in g Weig h t - lb s (kg ) 68.4 (31.0) 78.7 (35.7) 78.7 (35.7) B attery P arameters Typ e B attery Qty x Vo ltag e x R atin g Valve-regulated, nonspillable, lead acid (3) x 12 V x 7 or 7.2 AH B attery Mfg / P art N u mb er (4) x 12 V x 7 or 7.2 AH (8) x 12 V x 65 AH CSB GP1270F2 or Panasonic LC-R127R2CH1 B ack-u p T ime R ech arg e T ime (8) x 12 V x 6.5 or 7.0 AH See Battery Run Time Charts <20 hours to 95% capacity after full discharge into 100% load 5 hours to 95% capacity after full discharge into 100% load E n viro n men tal Op eratin g Temp eratu re +32oF to +104oF (0oC to +40oC) S to rag e Temp eratu re +5oF to +122oF (-15oC to +50oC) R elative H u mid ity 0% to 95%, non-condensing Up to 10,000 ft. (3000 m) at 104oC (40oC) without derating Op eratin g E levatio n S to rag e E levatio n 15.000 m (50,000 ft.) maximum Ag e n c y S a fe ty UL 1778, c-UL listed, TUV, CE Low Voltage Directive compliant R F I/E MI Immu n ity FCC Part 15, Subpart B, Class A; EN5022, Class B; CE ECM Compliant IEEE 587, Category A; IEC 801-2, Level 4 IEC 801-3, Level 3 IEC 801-4, Level 4 IEC801-5, Level 3 EN61000-4-5, Level 3 EN50082-1 Fax-on-Demand #: (877) 888-9329, Document #: 8375 Contact Technical Services at (800) 377-4384 with any questions. N/A 181 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Sola 4000 Guide Specifications Fax-on-Demand # 8226 CSI 16261 - Static Uninterruptible Power Supply Systems - Sola 4000 Guide Specifications for a 700 to 1000 VA Mini Tower 1000 to 3000 VA Tower Rack Single - Phase Uninterruptible Power Supply System 1.0 GENERAL 1.1 SUMMARY This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty single-phase, solid-state, uninterruptible power system. The uninterruptible power system, hereafter referred to as the UPS, shall provide high-quality AC power for sensitive electronic equipment loads. 1.2 STANDARDS The UPS shall be designed in accordance with the applicable sections of the current revision of the following documents. Where a conflict arises between these documents and statements made herein, the statements in this specification shall govern. 120V Units • • • • • • UL Standard 1778 FCC Part 15, Class A IEEE 587, Category A C-UL (to CSA 22.2 No. 107.1) National Electrical Code (NFPA 70) ISTA Project 1A 230V Units • EN 50091-1(Incorporating EN60950) TUV/GS Listed • EMC- EN50091-2 (Incorporating) EN 55022, Class B IEC 801-2, Level 4 IEC 801-3, Level 3 IEC 801-4, Level 4 IEC 801-5, Level 2 • CE compliance mark, For both Low Voltage and EMC Directives • ISTA Project 1A 1.3. SYSTEM DESCRIPTION 1.3.1 Modes of Operation The UPS shall be designed to operate as a true on-line system in the following modes: A. Normal - The critical AC load is continuously supplied by the UPS inverter. The input converter derives power from a utility / mains AC source and supplies DC power to the inverter. The battery charger shall maintain a float-charge on the battery. 1 Fax-on-Demand Number: (877) 888-9329 Document #: 8226 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com B. Battery - Upon failure of utility / mains AC power, the critical AC load is supplied by the inverter, which obtains power from the battery. There shall be no interruption in power to the critical load upon failure or restoration of the utility / mains AC source. C. Recharge - Upon restoration of utility / mains AC power, after a utility / mains AC power outage, the input converter shall automatically restart and assume supplying power to the inverter. Also the battery charger shall recharge the battery. D. Automatic Restart - Upon restoration of utility / mains AC power, after a utility / mains AC power outage and complete battery discharge, the UPS shall automatically restart and assume supplying power to the critical load. Also the battery charger shall automatically recharge the battery. This feature shall be capable of being disabled be the user. E. Bypass - The integral bypass shall perform an automatic transfer of the critical AC load from the inverter to the bypass source, in the event of an overload, PFC failure, over temperature, DC Bus over voltage, or inverter failure conditions. 1.3.2 Design Requirements A. Voltage: Input/output voltage specifications of the UPS shall be: Input: 120V Units: 0 - 138 VAC, 60/50 Hz, single-phase, 2-wire-plus- ground. 230V Units: 0 -276 VAC, 50/60 Hz, single-phase, 2-wire-plus- earth. Output: 120 V Units: 120 VAC +/-3%, 60/50 Hz, single-phase, 2-wire-plus-ground, switch selectable (100V,110V,120V,127V) 230 V Units: 230 VAC +/-3%, 50/60 Hz, single-phase, 2-wire-plus-earth, switch selectable (208V,220V,230V,240V) B. Output Load Capacity: Specified output load capacity of the UPS shall be: (____) VA at 0.7 lagging power factor. C. Internal Battery: The battery shall consist of valve regulated, non-spillable, lead acid cells. D. Reserve Time: Minimum 5 minutes at full load with ambient temperature 25°C (77°F). E. Battery Recharge: The UPS shall contain a battery recharge rate designed to prolong battery life. Recharge time shall be five (5) hours maximum to 95% capacity after a complete discharge into full load. 2 Fax-on-Demand Number: (877) 888-9329 Document #: 8226 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 1.3.3 Performance Requirements 1.3.3.1 AC Input to UPS A. Voltage Configuration The UPS shall operate at these values without drawing power from the batteries. 120 VAC; single phase, 2 wire plus ground nominal; variable based upon output loading: LOAD 700/1000 VA MODEL 1500-3000 VA MODEL 100 - 90% 80 - 83 VAC to 134 -138 VAC 90 - 93 VAC to 134 - 138 VAC 90 - 70% 80 - 83 VAC to 134 - 138 VAC 80 - 83 VAC to 134 - 138 VAC 70 - 30% 70 - 73 VAC to 134 - 138 VAC 70 - 73 VAC to 134 - 138 VAC 30 - 0% 60 - 62 VAC to 134 - 138 VAC 60 - 62 VAC to 134 - 138 VAC 230 VAC; single phase, 2 wire plus earth nominal; variable based upon output loading: LOAD 700/1000 VA MODEL 1500-3000 VA MODEL 100 - 90% 160 - 163VAC to 273 - 276VAC 184 - 187VAC to 273 - 276VAC 90 - 70% 160 - 163VAC to 273 - 276VAC 160 - 163VAC to 273 - 276VAC 70 - 30% 140 - 143VAC to 273 - 276VAC 140 - 143VAC to 273 - 276VAC 30 - 0% 120 - 123VAC to 273 - 276VAC 120 - 123VAC to 273 - 276VAC B. Frequency: UPS auto senses input frequency and will operate within the following frequency specifications. • 50 Hz Applications: • 60 Hz Applications: 45 - 55 Hz 55 - 65 Hz C. Input Power Factor: 0.95 lagging minimum at rated load. D. Surge Protection: 120 VAC nominal units shall sustain input surges without damage per criteria listed in IEEE 587, Category A. 230 VAC nominal units shall sustain input surge without damage per criteria listed in IEC 801 - 5, Level 3. 1.3.3.2 AC Output, UPS Inverter A. Voltage Configuration: 120 V Units: 120 VAC, 60/50 Hz, single-phase, 2-wire-plus-ground, switch selectable (100V,110V,120V,127V) 230 V Units: 230 VAC, 50/60 Hz, single-phase, 2-wire-plus-earth, switch selectable (208V,220V,230V,240V) B. Voltage Regulation: +/- 3% steady state. 3 Fax-on-Demand Number: (877) 888-9329 Document #: 8226 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com C. Frequency Regulation: +/- 3 Hz Synchronized to utility / mains. +/- 0.1 Hz free running or on battery operation. D. Frequency Slew Rate: 1.0 Hertz per second maximum E Voltage Distortion: 4% total harmonic distortion (THD) typical into a 100% linear load, 7% THD typical into a 100% non-linear load with crest factor ratio of 3:1 F. Load Power Factor Range: 0.5 lagging to 1.0 (unity). G. Output Power Rating: Rated VA at 0.7 lagging power factor. H. Inverter Overload Capability: 112 - 130% of full load for 10 second, 131 - 200% of full load for 8 cycles. I. Voltage Transient Response: +/- 11% in line mode, +/- 15% in battery mode for any load step up to and including 100% of the UPS rating. J. Transient Recovery Time: To steady state output voltage within 90 milliseconds. 1.4 ENVIRONMENTAL CONDITIONS A. Ambient Temperature o o o o o o o Operating: 0 C to +40 C (+ 32 F to + 104 F) for altitudes 0 to 1500 meters (0 to 5,000 ft.) above sea level o 0 C to +35 C (+ 32 F to + 95 F) for altitudes 1500 to 3000 meters (5,000 to 10,000 ft.) above sea level o o 25 C (+ 77 F) for optimum battery performance Storage: o o o o -15 C to +50 C (+ 5 F to +122 F) o o 20 C (+ 68 F) for optimum battery storage. B. Relative Humidity Operating: 0 to 95% non-condensing. Storage: 0 to 95% non-condensing. C. Altitude: 3,000 m (10,000 ft. max.) Without power derating when operated within the temperature specified in Section 1.4.A. D. Audible Noise Noise generated by the UPS under any condition of normal operation shall not exceed the following when measured at 1 meter from the surface of the UPS: 700-1000VA: 45 dBA 1500-3000VA: 50 dBA E. Electrostatic Discharge The UPS shall be able to withstand a electrostatic discharge compliant to IEC 801- 2, level 4 (15 kV through air, 8 kV contact) without damage and shall not affect the connected load. 4 Fax-on-Demand Number: (877) 888-9329 Document #: 8226 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 1.5 USER DOCUMENTATION The specified UPS system shall be supplied with one (1) user's manual. Manuals shall include installation drawings and instructions, a functional description of the equipment with block diagrams, safety precautions, illustrations, step by step operating procedures, and general maintenance guidelines. 1.6 WARRANTY The UPS manufacturer shall warrant the UPS against defects in materials and workmanship for two (2) years. The warranty shall cover all parts and labor. An optional (1) and (3) year full coverage extension warranty shall be available from the manufacturer. 1.7 QUALITY ASSURANCE 1.7.1 Manufacturer Qualifications A minimum of twenty year's experience in the design, manufacture, and testing of solid-state UPS systems is required. The manufacturer shall be certified to ISO 9001. 1.7.2 Factory Testing Before shipment, the manufacturer shall fully and completely test the system to assure compliance with the specification. These tests shall include operational discharge and recharge tests on the internal battery to assure performance. 2.0 PRODUCT 2.1 FABRICATION All materials and components making up the UPS shall be new, of current manufacture, and shall not have been in prior service except as required during factory testing. The UPS shall be constructed of replaceable subassemblies. All active electronic devices shall be solid-state. All relays shall be provided with dust covers. 2.1.2 Wiring Wiring practices, materials, and coding shall be in accordance with the requirements the standards listed in Section 1.2 and other applicable codes and standards. All wiring shall be copper. 5 Fax-on-Demand Number: (877) 888-9329 Document #: 8226 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 2.1.3 Cabinet The UPS unit comprised of: input converter, battery charger, inverter, and battery consisting of the appropriate number of sealed battery cells, shall be housed in a mini - tower or rack - tower NEMA type 1 enclosure and meets the requirements of IP20. The UPS cabinet shall be cleaned, primed, and painted with the manufacturer's standard color. Dimensions and weight shall be: 2.1.4 MODEL DIMENSION (W x D x H) WEIGHT S4700 6.4” x 15.6” x 8.9” (162mm) x (397mm) x (225mm) 28.8lbs. (13.1kg) S41000 6.4” x 15.6” x 8.9” (162mm) x (397mm) x (225mm) 34.8lbs. (15.8kg) S41000TRM 7.0” x 19.3” x 16.9” (177mm) x (490mm) x (430mm) 51.9lbs. (23.6kg) S41500TRM 7.0” x 19.3” x 16.9” (177mm) x (490mm) x (430mm) 60.9lbs. (27.7kg) S42000TRM 7.0” x 19.3” x 16.9” (177mm) x (490mm) x (430mm) 80.9lbs. (36.8kg) S43000TRM 7.0” x 19.3” x 16.9” (177mm) x (490mm) x (430mm) 85.9lbs. (39.0kg) Cooling The UPS shall be forced air cooled by an internally mounted, two speed fan. Fan power shall be provided from the internal DC supply. Air intake shall be through the front of the unit and exhausted out the rear. 2.2 COMPONENTS 2.2.1 Input Converter 2.2.1.1 General Incoming AC power shall be converted to a regulated DC output by the input converter for supplying DC power to the inverter. The input converter shall provide input power factor correction and input current distortion reduction. 2.2.1.2 AC Input Current Limit The input converter shall be provided with AC input current limiting whereby the maximum input current shall be limited to 125% of the full load input current rating. 2.2.1.3 Input Protection The UPS shall have built-in protection against undervoltage, overcurrent, and overvoltage conditions including low-energy lightning surges, introduced on the primary AC source. The 120 VAC UPS shall sustain input surges without damage per criteria listed (IEEE 587 CAT. A). The 230 VAC UPS shall sustain input surges without damage per criteria listed in IEC 801 - 05, Level 3. Additionally, the UPS clamping voltage shall be 320V (for 240V) and 175V (for 120V) peak and energy dissipation shall be 80 joules for 230V and 50 joules for 120V for 2 milliseconds. The 120V models 700, 1000, 1500 VA UPS shall have input fuses; the 2000, 3000 VA UPS shall have input circuit protectors. The 230V models 700, 1000 VA UPS shall have input fuses; the 1500, 2000, 3000 VA UPS shall have input circuit protectors. 6 Fax-on-Demand Number: (877) 888-9329 Document #: 8226 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 2.2.1.4 Battery Recharge The UPS shall contain a battery recharge rate designed to prolong battery life. The battery shall be constant current charged to restore capacity, then shall be constant voltage charged to maintain the battery in a fully charged state. Recharge time shall be five (5) hours maximum to 95% capacity (5 minute discharge rate). There shall be DC overvoltage protection so that if the DC voltage exceeds the pre-set limit, the UPS shall shutdown automatically and the critical load shall be transferred to bypass. 2.2.2 Inverter 2.2.2.1 General The UPS inverter shall be pulse-width-modulated (PWM) design capable of providing the specified AC output. The inverter shall convert DC power from the input converter output, or the battery, into precise sine wave AC power for supporting the critical AC load. 2.2.2 Overload The inverter shall be capable of supplying current and voltage for overloads exceeding 100% and up to 200% of full load current. A visual indicator and audible alarm shall indicate overload operation. For greater currents or longer time duration, the inverter shall have electronic current-limiting protection to prevent damage to components. The inverter shall be self-protecting against any magnitude of connected output overload. Inverter control logic shall sense and disconnect the inverter from the critical AC load without the requirement to clear protective fuses. 2.2.2.3 Inverter DC Protection The inverter shall be protected by the following DC shutdown levels: DC Overvoltage Shutdown DC Undervoltage Shutdown (End of Discharge) DC Undervoltage Warning (Low Battery Reserve); factory set at 2 minutes 2.2.2.4 Output Frequency The output frequency of the inverter shall be controlled by an oscillator. The oscillator shall hold the inverter output frequency to +/- 0.1 Hz of nominal when not synchronized to the utility/mains source. 2.2.2.5 Output Protection The UPS inverter shall employ electronic current limiting and an output fuse. 2.2.2.6 Battery Over Discharge Protection To prevent battery damage from over discharging, the UPS control logic shall automatically raise the shutdown voltage set point; dependent upon output load at the onset of battery operation. 2.2.3 Display and Controls 2.2.3.1 General The UPS shall be provided with a microprocessor based unit status display and controls section designed for convenient and reliable user operation. The monitoring functions such as status and alarm indicators shall be displayed on an LED display. 2.2.3.2 System Indicators The UPS shall contain a row of LED's to indicate UPS load and battery capacity and five single LED's to indicate UPS status as described below: The "Fault" indicator shall illuminate red to indicate a UPS fault condition. The "Battery" indicator shall illuminate amber to indicate the UPS is operating from battery power. The "Bypass" indicator shall illuminate amber to indicate the UPS is operating on Bypass power. 7 Fax-on-Demand Number: (877) 888-9329 Document #: 8226 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com An audible alarm shall be provided and activated be any of the above alarm conditions. The "UPS ON" indicator shall illuminate green to indicate the UPS inverter is operating and supplying power. The "AC Input" indicator shall illuminate green to indicate the UPS is operating from utility / mains power. 2.2.3.3 Controls UPS start-up and shutdown operations shall be accomplished by the "On" and "Off" push buttons located on the front panel of the UPS. The "On" push button shall be a means to turn the UPS on and shall also serve as a means to manually test the battery, to reset active visual and audible alarms, and to allow manual transfers of the load from bypass power to the UPS inverter. The "Off" push button shall allow manual transfers of the load from the inverter to bypass power. Pressing the "Off" push button twice within a four second time period shall completely shutdown the UPS and its connected load. 2.2.4 On-Line Battery Test The UPS shall be provided with an automatic bi-weekly battery test feature. The test shall ensure the capability of the battery to supply power to the inverter while loaded. If the battery fails the test, the UPS shall display a warning message to indicate the batteries need replaced. The battery test feature shall be user accessible by the push button located on the front of the unit and with Power Surveillance software. This feature shall be capable of being disabled through the communications port. 2.2.5 Bypass 2.2.5.1 General A bypass circuit shall be provided as an integral part of the UPS. The bypass shall be rated to conduct 200% of full load current. The bypass control logic shall contain an automatic transfer control circuit that senses the status of the inverter logic signals, and operating and alarm conditions. This control circuit shall provide a transfer of the load to the bypass source, without exceeding the transient limits specified herein, when a malfunction occurs within the UPS. 2.2.5.2 Automatic Transfers The transfer control logic shall automatically activate the bypass, transferring the critical AC load to the bypass source, after the transfer logic senses one of the following conditions: • • • • • UPS overload UPS over temperature PFC failure Inverter failure DC Bus Overvoltage Once overload condition is reduced, the load shall be automatically transferred back to inverter power. 2.2.6 Internal Battery Valve regulated, non-spillable, lead acid cells shall be used as a stored-energy source for the specified UPS system. The battery shall be housed internal to the UPS cabinet, and sized to support the inverter at rated load and power factor, with ambient temperature of 25 deg C (77 deg F) for a minimum of 5 minutes reserve time. The expected life of the battery shall be 3 - 5 years or a minimum 250 complete discharge cycles. The UPS units shall have the capability to allow the operator to replace the internal battery. 8 Fax-on-Demand Number: (877) 888-9329 Document #: 8226 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 2.2.7. Output Distribution Output distribution is integral to the UPS, located on the rear of the unit. MODEL 120 VAC Units 230 VAC Units S4700 (4) NEMA 5-15R (4) CEE 22 S41000 (4) NEMA 5-15R (4) CEE 22 S41000TRM (8) NEMA 5-15R (4) CEE 22 S41500TRM (8) NEMA 5-15R (4) CEE 22 (6) NEMA 5-15R, S42000TRM (4) CEE 22 (2) NEMA 5-20R (6) NEMA 5-15R, (1) NEMA L5-30R S43000TRM 2.2.8 (4) CEE 22, (1) CEE 19 Communications The UPS shall contain a DB9F (9 pin female) connector on the rear panel to allow UPS status communications to a computer system. The DB9F shall contain photo couplers to signal on battery and low battery operational status. The UPS shall also be capable of receiving a signal from the connected host system to initiate an UPS shutdown. This signal shall be a + 5 V to +12 V (RS232 level) that must remain for > 0.75 second duration. Additionally, it shall also communicate via serial communications using Sola/Hevi-Duty ESP II protocol. Communications protocol shall be Sola/Hevi-Duty ESP II, level 1 compliant; with the following exceptions: Sola/Hevi-Duty ESP II, Level 1 items not supported: - Input amperes - Minutes - Date - Input Undervoltage Startup fail - Battery amperes - Hours - Month - Seconds - Day of Week - Year The pin out configuration of the DB9F connector shall be: Pin 1 2 3 4 5 6 7 8 9 Assignment Description Low Battery (Open Collector: +V) UPS TxD UPS RxD Remote Shutdown (5-12V DC,1.0 mA max.); on battery operation Common Remote shutdown (Short to Pin 5); any mode operation Low Battery (Open Emitter: -V) Utility / mains Fail (Open Emitter: -V) Utility/Mains Fail (Open Collector; +V) Maximum voltage and current on pins 1,7,8,9 shall be 80 VDC, 10.0 mA maximum. 9 Fax-on-Demand Number: (877) 888-9329 Document #: 8226 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 2.2.9 Optional Communications The UPS shall contain one communication slot to allow the operator to field install optional communication cards. These optional cards shall allow the UPS to communicate via Ethernet SNMP, connected directly to the LAN. Once the SNMP card is installed, the serial communications shall be disabled in the DB9F connector; however the photo-coupler signals (on battery, and low battery) shall remain active. The communication port shall be designed to provide simple installation where electrical connections are made via a 26 pin edge card connector. 2.2.9 Optional External Battery Cabinet Either 1 or 2 external battery cabinet(s) shall be provided for the UPS Rack / Tower (1000 VA- 3000 VA only). The battery cabinet(s) shall be used in parallel with the internal battery for extended power outage reserve time. Each battery cabinet shall contain valve regulated, non - spillable, lead acid cells, housed in a separate cabinet that matches the UPS cabinet styling. Inter-cabinet wiring with mating connectors shall be supplied with the external battery cabinet. Each battery cabinet shall contain circuit breaker to provide individual cabinet overcurrent protection and isolation. The external battery cabinet(s) shall increase power outage reserve time when operating with ambient temperature of 25degC (77 deg F). NOTE: These Guide Specifications comply with the format outlined by the Construction Specifications Institute per CSI MP-2-1 and CSI MP-2- 2. In correspondence, refer to Sola/Hevi-Duty document SL-23140. G:/techsvcspecs/info/cdrominfo/ups/guidespecs/4000GuideSpec.doc (8/99) 10 Fax-on-Demand Number: (877) 888-9329 Document #: 8226 Contact Technical Services at (800) 377-4384 with any questions. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com