Preview only show first 10 pages with watermark. For full document please download

3ware ® Product Guide

   EMBED


Share

Transcript

H A R D W A R E R A I D Spring/Summer 2008 3ware® Produc t Guide C O N T R O L L E R S Sales Offices for 3ware Products: 215 Moffett Park Drive Sunnyvale, CA 94089 Tel: +1-408-542-8771 +1-877-883-9273 Email: [email protected] www.3ware.com Europe: +44-1494-890700 Asia/Pacific: +65-6826-3381 China: +86-10-6581-4916 AMCC reserves the right to make changes to its products, or to discontinue any product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the information being relied upon is current. For the latest 3ware product information, visit www.3ware.com. AMCC is a registered trademark of Applied Micro Circuits Corporation. 3ware, 3DM and StorSwitch are registered trademarks of Applied Micro Circuits Corporation in the United States. All other trademarks are the property of their respective holders. Copyright © 2008 Applied Micro Circuits Corporation. All Rights Reserved. FamPG_031908 Ta b l e o f C o n t e n t s AMCC Headquarters in Sunnyvale, CA • Industry leading 3ware® Serial Attached SCSI and Serial ATA RAID controllers for performance, capacity and peace of mind • Leading1 supplier of SATA II hardware RAID controllers and solutions to premier channel partners • Over 3.0 million SATA ports shipped 1 3ware RAID Controllers — The Right Tool for the Job 1 3ware 9690SA 2 3ware 9650SE 3 3ware 9550SXU 3 3ware Sidecar 4 xSATA vs. eSATA, FireWire and USB 4 Multi-lane Cables and Connectors 5 3ware Controller/Cable Matrix 6 Battery Backup Units 8 3ware Features and Benefits 8 Putting the Pieces Together 9 Common RAID Levels 9 Hardware vs Software RAID 9 Red Hot RAID 6 10 3ware RAID Controller Part Number Matrix 10 Worldwide 3ware Distributors and Sales Offices 11 Source: Gartner Dataquest Host Bus RAID Controllers Report (September 2006) 3ware RAID Controllers The Right Tool for the Job 3ware pioneered the way for SATA and we now capitalize on our time-proven serial storage expertise to take users from SCSI to SAS. Most importantly, whether our customers require SAS, SATA or combined SAS/SATA connectivity, 3ware will provide the right tool for the job. SATA SAS The cost- and performance-optimized interface for the majority of value-end storage appliances that employ a fixed number of drives to serve vertical applications, like video surveillance. The interface for the direct-attach server space, SCSI’s former mainstay. SAS is for mission critical applications that require higher levels of availability and native expansion. • • • • • • • • • Vertical Applications Cost Optimized Optimized for Sequential Performance Mature Infrastructure Mission Critical Applications High Availability Native Expansion Optimized for Random Performance Emerging Infrastructure Advanced RAID features, SAS and SATA II connectivity, and powerful 3ware performance architecture make 3ware controllers ideal for vertical applications that require the highest levels of sustained write and read performance. A P P L I C AT I O N S F O R 3 WA R E CO N T R O L L E R S Servers Security/ Surveillance Pro Video Super Computing NAS Video On-Demand Pro Audio Disk-to-Disk Backup 1 Expand Your Horizon with SAS Connectivity, Data Protection and Performance. 3ware® 9690SA High Performance Serial Attached SCSI (SAS) RAID Controllers 3ware pioneered the way for SATA and now capitalizes on timeproven serial storage expertise to take users from parallel SCSI to SAS. The 9690SA seizes the moment to enter the market just as SAS hard drives, expanders and backplanes are more widely available and as enterprise infrastructures align to realize the potential of Serial Attached SCSI. As SAS makes inroads into the SCSI market, users will look to SAS to provide expanded connectivity and greater scalability and to the 3ware 9690SA for peace of mind. SAS 3ware 9690SA Specifications • Scalable to 128 SAS and/or Serial ATA devices • PCI Express eight lane (x8) host interface • Configuration flexibility with four configuration options — 8 internal ports — 8 external ports — 4 internal/four external ports — 4 internal ports • SAS, SATA, and SATA II features, including 3Gb/s and NCQ • Low profile form factor • 512MB DDR2 533 ECC protected memory • RAID levels 0, 1, 5, 6, 10, 50 and Single Disk • RoHS 6 of 6 and WEEE compliant 3ware 9690SA Series Selection Guide Form Factor SAS Ports Drive Interface PCI Express RAID Levels Onboard Memory Connector Type BBU with Remote Battery Support 9690SA-8I 9690SA-8E 9690SA-4I4E 9690SA-4I Low profile 8 Internal SAS and SATA x8 0, 1, 5, 6, 10, 50, Single Disk 512MB DDR2 533 SFF-8087 mini-SAS Yes Low profile 8 External SAS and SATA x8 0, 1, 5, 6, 10, 50, Single Disk 512MB DDR2 533 SFF-8088 mini-SAS Yes Low profile 4 Internal/4 External SAS and SATA x8 0, 1, 5, 6, 10, 50, Single Disk 512MB DDR2 533 SFF-8087/SFF-8088 mini-SAS Yes Low profile 4 Internal SAS and SATA x8 0, 1, 5, 6, 10, 50, Single Disk 512MB DDR2 533 SFF-8087 mini-SAS Yes 2 3ware® 9650SE High Performance PCI Express to Serial ATA II RAID Controllers The best keeps getting better with red hot RAID 6 AMCC’s 3ware 9650SE SATA II hardware RAID controllers deliver industry-leading RAID 6 and RAID 5 performance, robust fault tolerance, and multi-terabyte capacities. A PCI Express host interface, Multi-lane™ connectivity, StorSwitch™ architecture, and sophisticated SATA II features drive this unrivaled performance. 3ware 9650SE Specifications • PCI Express x1, x4, x8 configurations • Serial ATA II advanced features — 3Gb/s transfer speed — Native Command Queuing • Low profile form factor — 2, 4, 8-port configurations • Full height form factor — 12, 16, 24-port configurations • RAID levels: 0, 1, 5, 6, 10, 50, Single Disk, JBOD (see chart below) • RoHS 6 of 6 and WEEE compliant 3ware 9650SE Series Selection Guide 9650SE-2LP 9650SE-4LPML 9650SE-4LPME 9650SE-8LPML Form Factor Port Count Drive Interface PCI Express Low profile 2 SATA x1 RAID Levels 0, 1, Single Disk, JBOD Onboard Memory Connector Type BBU Support 128MB DDR2 533 Discrete No Low profile 4 SATA x4 0, 1, 5, 10, Single Disk, JBOD 256MB DDR2 533 Multi-lane Yes Low profile 4 SATA x4 0, 1, 5, 10, JBOD 256MB DDR2 533 Multi-lane (external) Yes Low profile 8 SATA x4 0, 1, 5, 6, 10, 50, Single Disk, JBOD 256MB DDR2 533 Multi-lane Yes SATA 9650SE-12ML 9650SE-16ML 9650SE-24M8 Full height 12 SATA x8 0, 1, 5, 6, 10, 50, Single Disk, JBOD 256MB DDR2 533 Multi-lane Yes Full height 16 SATA x8 0, 1, 5, 6, 10, 50, Single Disk, JBOD 256MB DDR2 533 Multi-lane Yes Full height 24 SATA x8 0, 1, 5, 6, 10, 50, Single Disk, JBOD 512MB DDR2 533 Multi-lane Yes 3ware® 9550SXU* High Performance PCI-X to Serial ATA II RAID Controllers High Performance PCI-X RAID Solution of Choice The 3ware 9550SXU SATA II RAID controller delivers performance, robust fault-tolerance, and multi-terabyte capacities. Combined with an advanced RAID management feature set that includes web-based, command-based, and API software components, the 9550SXU, available in 4, 8, 12, and 16-port configurations, is the most compelling PCI-X solution available. 3ware 9550SXU Specifications • • • • • • PCI-X 1.0b (and PCI 2.3) compliant — 64-bit/133/100/66MHz bus master Serial ATA II advanced features — 3Gb/s transfer speed — Native Command Queuing Low profile (4 and 8-port) and full height form factors 4, 8, 12, and 16-port configurations RAID levels: 0, 1, 5, 10, 50, Single Disk, and JBOD (see chart below) RoHS 6 of 6 and WEEE compliant 3ware 9550SXU Series Selection Guide Form Factor Port Count Drive Interface Host Interface Host Interface Speed RAID Levels Onboard Memory Connector Type SATA 9550SXU-4LP 9550SXU-8LP 9550SXU-12 9550SXU-12MI Low profile 4 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, Single Disk, JBOD 128MB Discrete Low profile 8 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, 50, Single Disk, JBOD 128MB Discrete Full height 12 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, 50, Single Disk, JBOD 256MB Discrete Full height 12 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, 50, Single Disk, JBOD 256MB Multi-lane *A “U” has been added to all 9550SX part numbers to denote RoHS 6 of 6 compliance 9550SXU-12ML 9550SXU-16ML Full height 12 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, 50, Single Disk, JBOD 256MB Multi-lane Full height 16 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, 50, Single Disk, JBOD 256MB Multi-lane 3 3ware® Sidecar High-Performance Hardware RAID Storage for PC and Apple Workstations Think Outside the Box The 3ware® Sidecar featuring true hardware RAID is the only external storage choice for PCs, Apple® Mac Pro and Power Mac® G5 when capacity, performance, data protection, and ease of use are the goals. Broad OS support including Mac OS X, Windows, and Linux, an easily configurable RAID controller teamed with an intuitive management suite, and Multi-lane connectivity make the 3ware Sidecar as easy to use as 1-2-3. 3ware Sidecar Features Operating System Support • • • • • • • • • • High performance 4-port PCI Express to SATA II RAID controller for real hardware RAID — RAID levels 0, 1, 5, 10 and JBOD — 256MB DDR2 533 memory with ECC protection — BBU Support Complete configuration management suite — 3ware Disk Manager 2 (3DM®2) — Command Line Interface (CLI) 4-bay external Serial ATA desktop enclosure — Hot-swap and hot-spare support for easy maintenance — 4TB of external storage when loaded with 1TB drives (not included) — Front panel LED status indicators RoHS 6 of 6 and WEEE compliant (lead free) Microsoft Windows 2003/XP/2000 (32/64-bit) Microsoft Windows Vista (32/64-bit) Red Hat Linux, SuSE Linux, Fedora Core (32/64-bit) Linux Kernels 2.4, 2.6 (32/64-bit) FreeBSD (32/64-bit) Mac OS X (G5: 10.4.6+, Mac Pro: 10. 4.8) For complete OS listing, go to: www.3ware.com/support/OS-support 3ware Sidecar Minimum System Requirements • PC workstation, or Apple Mac Pro, or Apple Power Mac G5 • Available PCI Express slot (x4 minimum) • Supported operating system Note: Power Mac G5 with PCI-X is not supported 4,000 800,000 1,500,000 40,000,000 xSATA up to 28x FASTER! 1200 1050 xSATA offers significantly faster transfer speeds, better scalability, and improved cabling options than eSATA, FireWire and USB interfaces. Interface Interface Speed xSATA eSATA FireWire 800 FireWire 400 USB 2.0 12Gb/s (1200MB/s) 3Gb/s (300MB/s) 800Mb/s (80MB/s) 400Mb/s (40MB/s) 480Mb/s (48MB/s) Note: These interfaces use 8b/10b encoding 750 600 450 300 150 12Gb/s (1200MB/s) xSATA vs. eSATA, FireWire and USB MB / Second 900 480Mb/s (48MB/s) Movies Digital Photos Songs Spreadsheets 800Mb/s (80MB/s) Quantity 400Mb/s (40MB/s) Movie=1GB Digital Photo=5MB Song=3MB Spreadsheet=100KB Data 3Gb/s (300MB/s) How Much is 4TB? 0 FireWire 400 FireWire 800 Interface Technology xSATA has a TOTAL speed-matching bandwidth of 1.2GB/s (300MB/s X 4-lanes!) eSATA Solutions share the 300MB/s bandwidth among the available lanes (300MB/s ÷ 4 lanes) 4 Multi-lane™ High-Performance SAS and SATA Cable and Connector System Multi-lane Benefits Get Connected via the Multi-lane™ Expressway AMCC’s award winning Multi-lane design enables highly reliable and streamlined enterprise-class SAS and SATA storage solutions by greatly reducing the number of cables needed to connect controllers, backplanes, and standard SAS/SATA drives. The Multi-lane SATA cable/connection system is fast, secure, simple, and clutter free. It combines the RAID controller’s multiple SAS/SATA ports into single locked connections. Multiple 3Gb/s lanes of SAS/SATA traffic travel through just one cable from the RAID controller to the system backplane or to multiple hard drives with a breakout cable. • Multiple lanes of high speed SAS and/or SATA traffic through a single cable • Increased system reliability • Reduced cable count • Streamlined storage • Locked connections • Improved airflow Multi-lane SAS and SATA Cable and Connector Systems SFF-8088 to SFF-8088 SFF-8088 to SFF-8470 SFF-8087 to SFF-8482 SFF-8087 to SFF-8087 SFF-8087 to Discrete 3ware Controller Model # 9690SA (-8E, -4I4E) 3ware Controller Model # 9690SA (-8E, -4I4E) 3ware Controller Model # 9690SA (-8I, -4I4E, 4I) 3ware order # CBL-SFF8088SAS-10M (1.0 m) CBL-SFF8088SAS-20M (2.0 m) 3ware order # CBL-SFF8088IB-10M (1.0 m) CBL-SFF8088IB-20M (2.0 m) 3ware order # CBL-SAS8087OCF-06M (0.6 m) 3ware Controller Model # 9690SA (-8I, -4I4E, 4I) 9650SE (-4LPML, -8LPML, -12ML, -16ML) 9550SXU (-12ML, 16ML) 3ware Controller Model # 9690SA (8I, 4I4E, 4I) 9650SE (-4LPML, -8LPML, -12ML, -16ML) 9550SXU (-12ML, -16ML) 3ware order # CBL-SFF8087-05M (0.5 m) CBL-SFF8087-06M (0.6 m) 3ware order # CBL-SFF8087OCF-05M (0.5 m) CBL-SFF8087OCF-06M (0.6 m) CBL-SFF8087OCF-10M (1.0 m) (Multi-lane external SAS) (Multi-lane external SAS converter cable) (Forward SAS breakout cable w/ drive power connectors) (Multi-lane internal) (Forward breakout cable)* Discrete to SFF-8087 SFF-8087 to SFF-8470 M8 to SFF-8087 M8 to Discrete Discrete SATA 3ware Controller Model # 9550SXU (-4LP, -8LP, -12) 9500S-4LP 3ware Controller Model # 9650SE (-4LPML, -8LPML, -12ML, -16ML) 9550SXU (-12ML, -16ML) (SFF-8087 on controller) 3ware Controller Model # 9650SE-24M8 3ware Controller Model # 9650SE-24M8 3ware order # CBL-M8ML-06M (0.6 m) 3ware order # CBL-M8OCF-06M (0.6 m) CBL-M8OCF-10M (1.0 m) 3ware Controller Model # 9650SE-2LP 9550SXU (-4LP, -8LP, -12) 9500S-4LP 8006-2LP (Reverse breakout cable)* 3ware order # CBL-SFF8087OCR-05M (0.5 m) CBL-SFF8087OCR-06M (0.6 m) CBL-SFF8087OCR-10M (1.0 m) (Bi-directional Multi-lane hybrid cable) 3ware order # CBL-SFF8087IB-05M (0.5 m) CBL-SFF8087IB-06M (0.6 m) (Multi-lane internal “Y” cable) (Forward breakout cable)* (Standard, point-to-point SATA cable) 3ware order # CBL-SATA-39 (39”/1 m) Discrete to SFF-8470 SFF-8088 to SFF-8088 SFF-8470 to SFF-8087 SFF-8470 to SFF-8470 SFF-8470 to Discrete 3ware Controller Model # 9550SXU (-4LP, -8LP, -12) 9500S-4LP 3ware Controller Model # (3ware Sidecar) 3ware Controller Model # 9550SXU-12MI 3ware Controller Model # 9550SXU-12MI 3ware Controller Model # 9550SXU-12MI 3ware order # CBL-SFF8088-20M (2.0 m) 3ware order # CBL-SFF8087IB-05M (0.5 m) CBL-SFF8087IB-06M (0.6 m) 3ware order # CBL-IB-05M (0.5 m) CBL-IB-10M (1.0 m) 3ware order # CBL-OCF-18 (0.5 m) CBL-OCF-10M (1.0 m) (Reverse breakout cable)* 3ware order # CBL-OCR-18 (0.5 m) CBL-OCR-10M (1.0 m) * (Multi-lane external) (Bi-directional Multi-lane hybrid cable) Breakout cables have a Multi-lane connector on one end and discrete connectors on the other end • Forward breakout cables have a Multi-lane connector on the controller end and discrete connectors to the drives • Reverse breakout cables have discrete connectors on the controller end and a Multi-lane connector to the backplane Note: Cable color may differ from colors shown (Multi-lane internal) (Forward breakout cable)* 5 3ware Controller/Cable Matrix Connector to Connector Options Controller To Controller To Drives / Backplane Cable P/N Options Cable Description Where Used 3ware 9690SA SAS/SATA RAID Controllers 9690SA-8I 9690SA-8E 9690SA-4I4E 9690SA-4I SFF-8087 SFF-8087 CBL-SFF8087-05M CBL-SFF8087-06M 0.5 meter cable 0.6 meter cable Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s Multi-lane SFF-8087 connector(s) SFF-8087 SFF-8482 CBL-SAS8087OCF-06M 0.6 meter forward breakout cable Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four individual SAS or SATA drives; includes individual drive power connectors SFF-8087 Discrete CBL-SFF8087OCF-05M CBL-SFF8087OCF-06M CBL-SFF8087OCF-10M 0.5 meter forward breakout cable 0.6 meter forward breakout cable 1.0 meter forward breakout cable Connects the controller’s SFF-8087 Multi-lane connector(s) to the drives’ or backplane’s discrete SATA connector(s) SFF-8088 SFF-8088 SFF-8470 SFF-8088 SFF-8088 SFF-8088 SFF-8470 SFF-8087 SFF-8087 1.0 meter cable 2.0 meter cable 1.0 meter cable (converter cable) 2.0 meter cable (converter cable) 1.0 meter cable 2.0 meter cable 1.0 meter cable (converter cable) 2.0 meter cable (converter cable) 0.5 meter cable 0.6 meter cable Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s Multi-lane SFF-8088 connector(s) SFF-8088 CBL-SFF8088SAS-10M CBL-SFF8088SAS-20M CBL-SFF8088IB-10M CBL-SFF8088IB-20M CBL-SFF8088SAS-10M CBL-SFF8088SAS-20M CBL-SFF8088IB-10M CBL-SFF8088IB-20M CBL-SFF8087-05M CBL-SFF8087-06M SFF-8087 SFF-8482 CBL-SAS8087OCF-06M 0.6 meter forward breakout cable Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four individual SAS or SATA drives; includes individual drive power connectors SFF-8087 SFF-8087 CBL-SFF8087-05M CBL-SFF8087-06M 0.5 meter cable 0.6 meter cable Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s Multi-lane SFF-8087 connector(s) SFF-8087 SFF-8482 CBL-SAS8087OCF-06M 0.6 meter forward breakout cable Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four individual SAS or SATA drives; includes individual drive power connectors SFF-8087 Discrete CBL-SFF8087OCF-05M CBL-SFF8087OCF-06M CBL-SFF8087OCF-10M 0.5 meter forward breakout cable 0.6 meter forward breakout cable 1.0 meter forward breakout cable Connects the controller’s SFF-8087 Multi-lane connector(s) to the drives’ or backplane’s discrete SATA connector(s) Discrete Discrete CBL-SATA-39 39” (1m) standard, discrete, point-to-point SATA cable Connects a controller’s discrete SATA port(s) to the drives’ or backplane’s discrete SATA connector(s) SFF-8087 SFF-8087 CBL-SFF8087-05M 0.5 meter cable CBL-SFF8087-06M 0.6 meter cable Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s SFF-8087 Multi-lane connector(s) CBL-SFF8087OCF-05M 0.5 meter forward breakout cable SFF-8087 Discrete CBL-SFF8087OCF-06M 0.6 meter forward breakout cable CBL-SFF8087OCF-10M 1.0 meter forward breakout cable CBL-SFF8087IB-05M 0.5 meter converter cable (internal hybrid) CBL-SFF8087IB-06M 0.6 meter converter cable (internal hybrid) Connects the controller’s SFF-8087 Multi-lane (ML) connector(s) to the backplane’s SFF-8470 Multi-lane (MI) connector(s) CBL-M8ML-06M 0.6 meter “Y” cable Connects the controller’s M8 Multi-lane connector(s) to the backplane’s SFF-8087 Multi-lane connector(s) CBL-M8OCF-06M 0.6 meter forward breakout cable CBL-M8OCF-10M 1.0 meter forward breakout cable CBL-SFF8088-20M 2.0 meter cable Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s Multi-lane SFF-8470 connector(s) Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s Multi-lane SFF-8088 connector(s) Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s Multi-lane SFF-8470 connector(s) Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s Multi-lane SFF-8087 connector(s) 3ware 9650SE Internal RAID Controllers 9650SE-2LP 9650SE-4LPML, -8LPML, -12ML, -16ML SFF-8087 SFF-8470 M8 SFF-8087 M8 Discrete 9650SE-24M8 Connects the controller’s SFF-8087 Multi-lane connector(s) to the drives’ or backplane’s discrete SATA connector(s) Connects the controller’s M8 Multi-lane connector(s) to the drives’ discrete SATA connectors 3ware 9650SE with External Connectivity (3ware Sidecar Only) 9650SE4LPME SFF-8088 SFF-8088 Connects the controller’s SFF-8088 Multi-lane connector to the 3ware Sidecar’s SFF-8088 Multi-lane connector 6 Connector to Connector Options Controller To Controller To Drives / Backplane Cable P/N Options Cable Description Where Used 3ware 9550SXU Internal RAID Controllers 9550SXU-4LP, -8LP, -12 9550SXU-12MI 9550SXU-12ML, 16ML Discrete Discrete Discrete SFF-8087 Discrete SFF-8470 SFF-8470 SFF-8470 SFF-8470 Discrete SFF-8470 SFF-8087 SFF-8087 SFF-8087 SFF-8087 Discrete SFF-8087 SFF-8470 Discrete Discrete Discrete SFF-8087 Connects the controller’s discrete SATA port(s) to the drives’ or backplane’s discrete SATA connector(s) CBL-SATA-39 39” (1m) standard, discrete, point-to-point SATA cable CBL-SFF8087OCR-05M 0.5 meter reverse breakout cable CBL-SFF8087OCR-06M 0.6 meter reverse breakout cable CBL-SFF8087OCR-10M 1.0 meter reverse breakout cable CBL-OCR-18 0.5 meter reverse breakout cable CBL-OCR-10M 1.0 meter reverse breakout cable CBL-IB-05M 0.5 meter cable CBL-IB-10M 1.0 meter cable CBL-OCF-18 0.5 meter forward breakout cable CBL-OCF-10M 1.0 meter forward breakout cable CBL-SFF8087IB-05M 0.5 meter converter cable (internal hybrid) CBL-SFF8087IB-06M 0.6 meter converter cable (internal hybrid) CBL-SFF8087-05M 0.5 meter cable CBL-SFF8087-06M 0.6 meter cable CBL-SFF8087OCF-05M 0.5 meter forward breakout cable CBL-SFF8087OCF-10M 1.0 meter forward breakout cable CBL-SFF8087IB-05M 0.5 meter converter cable (internal hybrid) CBL-SFF8087IB-06M 0.6 meter converter cable (internal hybrid) Connects the controller’s SFF-8087 Multi-lane (ML) connector(s) to the backplane’s SFF-8470 Multi-lane (MI) connector(s) CBL-SATA-39 39” (1m) standard, discrete, point-to-point SATA cable Connects the controller’s discrete SATA port(s) to the drives’ or backplane’s discrete SATA connector(s) CBL-SFF8087OCR-05M 0.5 meter reverse breakout cable CBL-SFF8087OCR-06M 0.6 meter reverse breakout cable CBL-SFF8087OCR-10M 1.0 meter reverse breakout cable CBL-SATA-39 39” (1m) standard, discrete, point-to-point SATA cable Connects the controller’s discrete SATA port(s) to the backplane’s SFF-8087 Multi-lane connectors Connects the controller’s discrete SATA connector(s) to the backplane’s SFF-8470 Multi-lane connector(s) Connects the controller’s SFF-8470 Multi-lane connector(s) to the backplane’s SFF-8470 Multi-lane connector(s) Connects the controller’s SFF-8470 Multi-lane connector(s) to the drives’ or backplane’s discrete SATA connector(s) Connects the controller’s SFF-8470 Multi-lane (MI) connector(s) to the backplane’s SFF-8087 Multi-lane (ML) connector(s) Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s SFF-8087 Multi-lane connector(s) Connects the controller’s SFF-8087 Multi-lane connector(s) to the drives’ or backplane’s discrete SATA connector(s) 3ware 9500S and 8006 Internal RAID Controllers 9500S-4LP Connects the controller’s discrete SATA port(s) to the backplane’s SFF-8087 Multi-lane connectors 8006-2LP Discrete Discrete Connects a controller’s discrete SATA port(s) to the drives’ or backplane’s discrete SATA connector(s) Internal SFF-8087 or M8 Multi-lane Quick Reference Chart Cable/connector Controller P/N Suffix Connectivity Also Known as SFF-8470 MI Internal InfiniBand SFF-8087 ML Internal Mini SAS 4i, Mini SATA Internal, iPass SFF-8088 ME External Mini SAS 4x, Mini SATA External, iPass M8 M8 Internal — Backplane SFF-8087 or SFF-8470 External SFF-8088 Multi-lane SFF-8087 and M8 cables provide internal connectivity from the controller to drives or the backplane. Multi-lane SFF-8088 cables provide external connectivity from the controller to external enclosures. 7 Battery Backup Units BBU-MODULE-03 BBU-MODULE-04 BBU Availability Features BBU Availability Features • • • • • • • • • Battery Mounting Option • • Battery attaches directly to the BBU Control Module The BBU Control module mounts directly to the RAID controller Includes all BBU-MODULE-03 features + Remote battery mounting capability for design flexibility Battery Mounting Options • • • Battery can attach to a BBU daughter card in various positions Battery can attach remotely to chassis wall, both internally and externally Remote mounting kit without battery available separately Compatible RAID Controllers • • • 3ware 9690SA 3ware 9650SE 3ware 9550SXU 2 1 2 3 3 1 Maximum reliability with cached write data protection Missing Array Detection Write Journaling Dynamic Sector Repair Drive Power-On Reset Detection Extensive Drive Timeout Recovery Out of Band Signaling Retry Up to 72 hours of data protection in the event of power failure 2 3 1 1 • • 3ware 9650SE 3ware 9550SXU 3 2 1 2 1 2 3 3 1 2 3 2 3 3 3 1 1 1 3 3 2 3 1 1 2 2 1 3 1 1 2 1 Compatible RAID Controllers 2 2 2 3 2 3 Battery placement options 3ware RAID Controller Features and Benefits StorSwitch™ Non-blocking switch fabric architecture Maximizes controller throughput by allowing concurrent communications with all attached SATA drives through a pool of 32 direct memory access (DMA) channels. Performance StorSave Powerful reliability enhancements Achieves unmatched data protection while maximizing performance in critical RAID modes when data availability, accessibility, and data protection are most needed. Data Protection StreamFusion Intelligent cache algorithm Maximizes application performance under heavy loads by dynamically allocating controller cache for maximum bandwidth Performance Multi-lane™ Award-winning connector system Dramatically increases subsystem reliability by radically reducing cable count and improves airflow RAID 6 (On select 3ware 9690SA and 9650SE controllers) Two sets of parity are simultaneously calculated, written, and rotated across all the drives. This allows the array to survive up to two drive failures without losing data, for significantly improved fault tolerance. Advanced Content Streaming (9690SA and 9650SE Controllers) Aggressively Caches write and read data and improves write and read content streaming. Provides intelligent caching algorithms to improve application performance in real world cases. Hybrid Initialization (9690SA and 9650SE Controllers) Faster foreground initialization for RAID 5 and RAID 6 arrays with 16 or more drives. Fastest background initialization for newly created arrays. Array Availability and Performance Accelerated RAID Recovery (9690SA and 9650SE Controllers) Faster rebuild completion. Shorter verify/initialization. Data Accessibility and Availability Reliability & Convenience Data Protection Application Performance 8 Putting the Pieces Together Advanced 3ware RAID Features and Performance Architecture StreamFusion Performance vs. Competition Host Data StorSwitch maximizes controller throughput — StorSwitch is a unique non-blocking switch fabric architecture that allows 3ware controllers to concurrently communicate to all attached SATA Disk #1 Disk #2 Disk #3 Disk #4 Disk #5 drives through a pool of 32 direct memory access (DMA) channels for unparalleled performance Block 1 P1 Parity Q1 Parity Block 2 Block 3 and data availability. The result is superior overall system performance compared to non-scalable P2 Parity Q2 Parity Block 5 Block 6 Block 4 hub-based systems that share the bandwidth of a single DMA channel. Block 8 P3 Parity Block 12 Block 11 Block 10 Q3 Parity Disk #1 Disk #2 Disk #3 Disk #4 B C D E F G H Disk #5 AMCC Competition 1 40 20 A0 B0 C0 0 Parity A1 B1 1 Parity D1 A2 0 StorSave optimizes data protection and performance — StorSaves’s revolutionary combination of powerful reliability enhancements and a battery backup unit (BBU) maximize data protection and system reliability without sacrificing controller performance. StorSave permits 3ware controllers to use both controller cache and disk cache during SATA RAID operations. This strengthens array performance during optimal usage, as well as during degraded RAID 5 and RAID 6 operations which Host Data means faster rebuild times. StorSave Profiles allow user-specified levels of protection vs. performance RAID 0 “Striping” (9690SA, 9650SE, 9590SE and 9550SXU only). Host Data A RAID 5 “Rotational Parity” 60 Striped Data with Distributed Double Parity — RAID 6 C2 2 Parity 2 B3 13 Parity 4 Competition 2 D2 C3 8 # Streams D3 16 SATA Disk V36OA60A/64KB stripes/RAID 5/all other settings at default Block 12 P4 Parity A Striped Data with Distributed Double Parity — RAID 6 Disk #1 Disk #2 Disk #3 Disk #4 Disk #5 = B 120 1 Parity D1 B A2 2 Parity C2 D2 3 Parity B3 C3 D3 Block 2 Block 3 SATA Disk Block 5 Block 6 SATA Disk Block 8 P3 Parity Q3 Parity Block 9 Block 12 Block 11 Block 10 P4 Parity RAID 0 “Striping” Q4 Parity RAID 0, 1, 5, 10 and JBOD 3 Parity 2 Parity C2 D2 B3 C3 D3 RAID 1 “Mirroring” B C D E F G H D H • Applications K requiringL high bandwidth A performance but no fault tolerance ETC. . . N O B • Video production/editing C • Pre-press applications A B C E F G M I J K N D1 A I M 0 Parity A2 Striped Data with Distributed Double Parity — RAID 6 RAID 0 “Striping” C0 L O = A C B1 D E I M B C F G H B0 C0 0 Parity B1 1 Parity ETC. . . D1 A2 2 Parity C2 D2 3 Parity B3 C3 D3 J N A0 A A1 K O L Hardware vs. Software RAID = SATA Disk C Drive 0 SATA Disk D1 D2 • Accounting D1 1 • Payroll Drive 1 • Financial 1 Mirror Stripe D1 D1 1 Drive 0 Drive 1 D2 D2 1 Drive 2 Drive 3 D2 D2 1 Drive 2 Drive 3 D2 Drive 3 RAID 10 "Striped Mirror" A1 • Most versatile RAID level providing performance, B B1 fault tolerance and storage efficiency C C1 • Video production/editing 1 D • File and applicationsD servers • Database servers • Email servers SATA Disk • News servers SATA Disk • Internet/Intranet B SATA D1 Disk 1 Drive 2 RAID 1 “Mirroring” D Mirror RAID 10 "Striped Mirror" • Provides fault tolerance and a read speed SATA Disk D1 D1 1 A 1 Mirror advantage over non-RAID disks Drive 0 Drive 1 Stripe requiring SATA Disk 1 • Applications high availability C1 RAID 5 “Rotational Parity” A = Stripe D1 RAID 10 "Striped Mirror" RAID 1 “Mirroring” 1 A D ETC. . . RAID 0 “Striping” SATA Disk B J 16 SATA Disk Block 1 1 Parity Competition 2 SATA Disk Q2 Parity B1 Competition 1 SATA Disk P2 Parity B0 AMCC SATA Disk Q1 Parity A1 D2 1 Drive 3 Iometer 2004.07.30dual Xeon 2.6 Ghz/1GB system/WinXP SP2/HDS7222525VLSA80/fw SATA Disk V36OA60A/64KB stripes/RAID 5/all other settings at default Block 4 A0 D2 Drive 2 1 P1 Parity Common RAID Levels Drive 1 Stripe 1 StreamFusion assures scalable high performance RAID 5 “Rotational Parity” Block 7 D1 1 D1 A1 StreamFusion Performance vs. Competition Drive 0 B1 Q4 Parity SATA Disk "Striped • Protects drive and controller cached writesRAID in the10event of aMirror" power loss RAIDcontroller 1 “Mirroring” • Uses and drive write cache in all modes Mirror • Dual caching for faster rebuild times 1 Block 11 SATA Disk I/O StreamFusion maximizes application performance under multiple loads — An I J K intelligent L C C 100 RAID 5 “Rotational Parity” ETC. . . D StreamFusion in Action cache algorithm dynamically optimizes RAID 5 and RAID accesses and manages N 3 efficiently O D Block 1 6 diskBlock P1 Parity Q1 Parity 2M Block 80 #1 Disk #2 Disk #3 for guaranteed Disk #4 Disk #5 dataDisk through controller cache bandwidth. As the number of data streams increases, 60 P2 Parity Q2 Parity Block 5 Block 6 Block 4 5 “Rotational Parity”A0 B0 C0 0 Parity the total bandwidth is divided equally among them. Application performance will not RAID suffer 40 Q3 Parity Block 9 Block 1 Block 7Block 2 Block 8Block 3 P3 Parity P1 Parity Q1 Parity B1 A1 20 1 Parity D1 during heavy traffic or when multiple applications are accessing data simultaneously. 3ware RAID P4 Parity Q4 Parity Parity Q2 Parity Block 10Block 5 Block 11Block 6 Block 12 Block 4 controllers are the performance bottleneck, as is often the case with softwareARAID and B0 HostP2not Data A2 00Parity 2 Parity C2 D2 0 C0 1 2 4 8 # Streams Block 8 controllers. P3 Parity Q3 Parity BlockDistributed 9 7 otherBlock hardware RAID Striped Data with Double Parity — RAID 6 3 Parity D3 B3 C3 Block 10 I/O I/O StreamFusion assures scalable high performance SATA Disk Iometer 2004.07.30dual Xeon 2.6 Ghz/1GB system/WinXP SP2/HDS7222525VLSA80/fw I/O A1 • Data is first mirrored, then striped across across the drives to provide double drive failure protection without the parity calculation performance penalty of RAID 5 and RAID 6. The mirror provides the redundancy. • Ability to recover from a drive failure in either mirrored set JBOD = Just a Bunch of Disks JBOD refers to an unconfigured disk attached to a RAID controller • No fault tolerance SATA Disk All AMCC 3ware RAID controllers incorporate onboard processors to deliver true hardware RAID. Software RAID schemes use the system’s processor, exploit host memory, compromise reliability and potentially rob the system of as much as 60% of its CPU cycles just to process RAID calculations. RAID 10 "Striped Mirror" RAID 1 “Mirroring” Mirror Hard Drive 3ware SATA Hardware RAID Controller StreamFusion in Action 80 Q4 Parity Hard Drive Advanced StorSwitch Architecture 100 Block 9 P4 Parity Hard Drive 120 ™ Block 7 Hard Drive Up to 1.5 Gb/sec per port 9 Host Data Red Hot RAID 6 The fastest RAID 6 available RAID 6 eliminates the risk of data loss if a second hard disk drive fails while the RAID array is rebuilding. In a 3ware RAID 6 system, two sets of parity are calculated, written, and rotated across all the drives. This second simultaneous P + Q parity calculation allows the array to survive up to two drive failures without losing data, for significantly improved fault tolerance. RAID 6-enabled 9690SA and 9650SE controllers deliver unequaled RAID 6 performance. RAID 6 represents a sea change in the RAID landscape. It provides the industry with higher levels of data protection, data availability and fault tolerance than RAID 5. By assuring data availability following a second drive failure, users can rest assured that they are enjoying maximum data protection, both in normal and degraded modes. And, with RAID 6-enabled 3ware controllers, RAID 6 will not cripple performance. Disk #1 Disk #2 Disk #3 Disk #4 Disk #5 P1 Parity Q1 Parity Block 1 Block 2 Block 3 Block 4 P2 Parity Q2 Parity Block 5 Block 6 Block 7 Block 8 P3 Parity Q3 Parity Block 9 Block 10 Block 11 Block 12 P4 Parity Q4 Parity Striped Data with Distributed Double Parity — RAID 6 3ware RAID 6: Two sets of parity data, P + Q, are striped across disks. RAID 6 safeguards against data loss during rebuild mode by allowing up to two consecutive drive failures for maximum fault tolerance. RAID 6 Enabled 3ware Controllers • 9690SA-8I • 9650SE-8LPML RAID 6 is recommended for: • 9690SA-8E • 9650SE-12ML • 9690SA-4I4E • 9650SE-16ML • High capacity systems with eight or more high capacity drives • 9690SA-4I • 9650SE-24M8 • Enterprise/mission critical installations 3ware RAID Controller Part Number Matrix 3ware 9690SA SAS/SATA Hardware RAID Controllers Model Number Host Interface Ports 9690SA-8I 9690SA-8E 9690SA-4I4E 9690SA-4I PCI Express x8 PCI Express x8 PCI Express x8 PCI Express x8 8 Internal 8 External 4 Internal/4 External 4 Internal RAID Levels Controller Connector Footprint RoHS 0, 1, 5, 6, 10, 50, Single Disk 0, 1, 5, 6, 10, 50, Single Disk 0, 1, 5, 6, 10, 50, Single Disk 0, 1, 5, 6, 10, 50, Single Disk SFF-8087 mini-SAS SFF-8088 mini-SAS SFF-8087 / SFF-8088 mini-SAS SFF-8087 mini-SAS Low profile Low profile Low profile Low profile 6/6 6/6 6/6 6/6 3ware 9650SE PCI Express-to-Serial ATA II Hardware RAID Controllers Model Number Host Interface Ports 9650SE-2LP 9650SE-4LPML 9650SE-4LPME 9650SE-8LPML 9650SE-12ML 9650SE-16ML 9650SE-24M8 PCI Express x1 PCI Express x4 PCI Express x4 PCI Express x4 PCI Express x8 PCI Express x8 PCI Express x8 2 4 4 8 12 16 24 RAID Levels Controller Connector Footprint RoHS 0, 1, Single Disk, JBOD 0, 1, 5, 10, Single Disk, JBOD 0, 1, 5, 10, JBOD 0, 1, 5, 6, 10, 50, Single Disk, JBOD 0, 1, 5, 6, 10, 50, Single Disk, JBOD 0, 1, 5, 6, 10, 50, Single Disk, JBOD 0, 1, 5, 6, 10, 50, Single Disk, JBOD Discrete Multi-lane (SFF-8087) Multi-lane (SFF-8088) Multi-lane (SFF-8087) Multi-lane (SFF-8087) Multi-lane (SFF-8087) Multi-lane custom hybrid Low profile Low profile Low profile Low profile Full height Full height Full height 6/6 6/6 6/6 6/6 6/6 6/6 6/6 3ware 9550SX PCI-X-to-Serial ATA II Hardware RAID Controllers Model Number Host Interface Ports 9550SXU-4LP 9550SXU-8LP 9550SXU-12 9550SXU-12MI 9550SXU-12ML 9550SXU-16ML 64-bit/133MHz 64-bit/133MHz 64-bit/133MHz 64-bit/133MHz 64-bit/133MHz 64-bit/133MHz 4 8 12 12 12 16 RAID Levels Controller Connector Footprint RoHS 0, 1, 5, 10, Single Disk, JBOD 0, 1, 5, 10, 50, Single Disk, JBOD 0, 1, 5, 10, 50, Single Disk, JBOD 0, 1, 5, 10, 50, Single Disk, JBOD 0, 1, 5, 10, 50, Single Disk, JBOD 0, 1, 5, 10, 50, Single Disk, JBOD Discrete Discrete Discrete Multi-lane (SFF-8470) Multi-lane (SFF-8087) Multi-lane (SFF-8087) Low profile Low profile Full height Full height Full height Full height 6/6 6/6 6/6 6/6 6/6 6/6 10 3ware 9500S PCI-to-Serial ATA Hardware RAID Controllers Model Number Host Interface 9500S-4LP 32/64-bit/66MHz Ports 4 RAID Levels Controller Connector Footprint RoHS 0, 1, 5, 10, Single Disk, JBOD Discrete Low profile 5/6 RAID Levels Controller Connector Footprint RoHS 0, 1, JBOD Discrete Low profile 5/6 3ware 8006 PCI-to-Serial ATA Hardware RAID Controller Model Number Host Interface Ports 8006-2LP 64-bit/66MHz 2 3ware Controller Specifications 3ware Controller Accessories Operating Systems Model Number Description BBU-MODULE-03 BBU-MODULE-04 Battery Backup Unit for 3ware 9650SE/9590SE/9550SX(U) Battery Backup Unit for 3ware 9690SA/9650SE/9590SE/9550SX(U); Includes remote battery mounting kit Replacement battery for BBU-MODULE-03 and BBU-MODULE-04 Battery Backup Unit for 3ware 9500S Replacement battery for BBU-9500S-01 SATA internal drive cage SATA drive tray (to be used with the RDC-400-SATA) Spare drive tray for 3ware Sidecar Please reference the cable datasheet PCI Compliance Serial Interface RAID Features SCSI Features SATA II Features Kit Contents Warranty Support Microsoft® Windows® 2003/XP/2000, Red Hat Linux, SuSE Linux, Fedora Linux, 2.4 Linux kernel, 2.6 Linux kernel, FreeBSD, 32/64-bit support, Mac OS X (10.4.6 and above) For complete OS listing, go to: www.3ware.com/support/OS-support PCI Express 1.1, PCI-X 1.0b, and PCI 2.3 compliant (64-bit/133/100/66MHz bus master) SATA and SATA II (1.5/ 3Gb/s), and SAS RAID 6 on select 3ware 9650SE controllers, RAID Level Migration, online capacity expansion, hot swap/hot spare, S.M.A.R.T. disk drive monitoring, multiple card support, multiple logical volumes and RAID levels, remote management, alert notifications and more Scatter/gather, command queuing, command reordering, elevator seek, dynamic sector repair, background media scanning and more 3Gb/s, Native Command Queuing, OOB Staggered Spin-up (compliant with the SATA 2.6 specification) SAS/SATA II/SATA RAID controller and cables, CD including driver, 3ware Disk Manager 2 (3DM®2), Command Line Interface (CLI), User Guide, Printed Installation Documentation 3 years Free technical support, advanced replacement option BATT-SPARE-02 BBU-9500S-01 BATT-9500S-SPARE RDC-400-SATA RDC-TRAY-SATA RDE-TRAY-01 CABLES Worldwide 3ware Distributors and Sales Offices 3ware Distributors North America Bell Micro (US and Canada) www.bellmicro.com Synnex (US and Canada) www.synnex.com D&H (US) www.dandh.com Latin America Bell Micro www.bellmicro.com/latinamerica Europe, Middle East and Africa Asbis www.asbis.com Avnet www.avnet.com Bell Micro www.bellmicro.eu.com Hammer www.hammerplc.com CTT www.ctt.de TMC www.tmc-uk.com 3ware Sales Offices Company Headquarters (USA) 215 Moffett Park Drive Sunnyvale, CA 94089 Tel: +1-408-542-8771 +1-877-883-9273 Email: 3waresales@ amcc.com www.3ware.com Asia Pacific APT (China) www.apt-storage.com ASK (Japan) www.ask-corp.co.jp Digicor (Australia) www.digicor.com.au Europe +44-1494-890700 Asia/Pacific +65-6826-3381 China +86-10-6581-4916 Epecom Graphics (Singapore) www.epecomgraphics.com.sg Synnex K.K. (Japan) www.synnex.co.jp THC (China) www.thcsy.com Upmost Technology Corp. (Taiwan) www.upmost.com.tw 11 Spring/Summer 2008 3ware® Produc t Guide H A R D W A R E R A I D C O N T R O L L E R S Sales Offices for 3ware Products: 215 Moffett Park Drive Sunnyvale, CA 94089 Tel: +1-408-542-8771 +1-877-883-9273 Email: [email protected] www.3ware.com Europe: +44-1494-890700 Asia/Pacific: +65-6826-3381 China: +86-10-6581-4916 AMCC reserves the right to make changes to its products, or to discontinue any product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the information being relied upon is current. For the latest 3ware product information, visit www.3ware.com. AMCC is a registered trademark of Applied Micro Circuits Corporation. 3ware, 3DM and StorSwitch are registered trademarks of Applied Micro Circuits Corporation in the United States. All other trademarks are the property of their respective holders. Copyright © 2008 Applied Micro Circuits Corporation. All Rights Reserved. FamPG_031908