3ware® Produc t Guide C O N T R O L L E R S
Sales Offices for 3ware Products: 215 Moffett Park Drive Sunnyvale, CA 94089 Tel: +1-408-542-8771 +1-877-883-9273 Email:
[email protected] www.3ware.com
Europe: +44-1494-890700 Asia/Pacific: +65-6826-3381 China: +86-10-6581-4916
AMCC reserves the right to make changes to its products, or to discontinue any product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the information being relied upon is current. For the latest 3ware product information, visit www.3ware.com. AMCC is a registered trademark of Applied Micro Circuits Corporation. 3ware, 3DM and StorSwitch are registered trademarks of Applied Micro Circuits Corporation in the United States. All other trademarks are the property of their respective holders. Copyright © 2008 Applied Micro Circuits Corporation. All Rights Reserved. FamPG_031908
Ta b l e o f C o n t e n t s
AMCC Headquarters in Sunnyvale, CA
• Industry leading 3ware® Serial Attached SCSI and Serial ATA RAID controllers for performance, capacity and peace of mind • Leading1 supplier of SATA II hardware RAID controllers and solutions to premier channel partners • Over 3.0 million SATA ports shipped 1
3ware RAID Controllers — The Right Tool for the Job
1
3ware 9690SA
2
3ware 9650SE
3
3ware 9550SXU
3
3ware Sidecar
4
xSATA vs. eSATA, FireWire and USB
4
Multi-lane Cables and Connectors
5
3ware Controller/Cable Matrix
6
Battery Backup Units
8
3ware Features and Benefits
8
Putting the Pieces Together
9
Common RAID Levels
9
Hardware vs Software RAID
9
Red Hot RAID 6
10
3ware RAID Controller Part Number Matrix
10
Worldwide 3ware Distributors and Sales Offices
11
Source: Gartner Dataquest Host Bus RAID Controllers Report (September 2006)
3ware RAID Controllers The Right Tool for the Job 3ware pioneered the way for SATA and we now capitalize on our time-proven serial storage expertise to take users from SCSI to SAS. Most importantly, whether our customers require SAS, SATA or combined SAS/SATA connectivity, 3ware will provide the right tool for the job.
SATA
SAS
The cost- and performance-optimized interface for the majority of value-end storage appliances that employ a fixed number of drives to serve vertical applications, like video surveillance.
The interface for the direct-attach server space, SCSI’s former mainstay. SAS is for mission critical applications that require higher levels of availability and native expansion.
• • • •
• • • • •
Vertical Applications Cost Optimized Optimized for Sequential Performance Mature Infrastructure
Mission Critical Applications High Availability Native Expansion Optimized for Random Performance Emerging Infrastructure
Advanced RAID features, SAS and SATA II connectivity, and powerful 3ware performance architecture make 3ware controllers ideal for vertical applications that require the highest levels of sustained write and read performance. A P P L I C AT I O N S F O R 3 WA R E CO N T R O L L E R S
Servers
Security/ Surveillance
Pro Video
Super Computing
NAS
Video On-Demand
Pro Audio
Disk-to-Disk Backup
1
Expand Your Horizon with SAS Connectivity, Data Protection and Performance. 3ware® 9690SA High Performance Serial Attached SCSI (SAS) RAID Controllers 3ware pioneered the way for SATA and now capitalizes on timeproven serial storage expertise to take users from parallel SCSI to SAS. The 9690SA seizes the moment to enter the market just as SAS hard drives, expanders and backplanes are more widely available and as enterprise infrastructures align to realize the potential of Serial Attached SCSI. As SAS makes inroads into the SCSI market, users will look to SAS to provide expanded connectivity and greater scalability and to the 3ware 9690SA for peace of mind.
SAS
3ware 9690SA Specifications • Scalable to 128 SAS and/or Serial ATA devices • PCI Express eight lane (x8) host interface •
Configuration flexibility with four configuration options — 8 internal ports — 8 external ports — 4 internal/four external ports — 4 internal ports
• SAS, SATA, and SATA II features, including 3Gb/s and NCQ • Low profile form factor • 512MB DDR2 533 ECC protected memory • RAID levels 0, 1, 5, 6, 10, 50 and Single Disk • RoHS 6 of 6 and WEEE compliant 3ware 9690SA Series Selection Guide Form Factor SAS Ports Drive Interface PCI Express RAID Levels Onboard Memory Connector Type BBU with Remote Battery Support
9690SA-8I
9690SA-8E
9690SA-4I4E
9690SA-4I
Low profile 8 Internal SAS and SATA x8 0, 1, 5, 6, 10, 50, Single Disk 512MB DDR2 533 SFF-8087 mini-SAS Yes
Low profile 8 External SAS and SATA x8 0, 1, 5, 6, 10, 50, Single Disk 512MB DDR2 533 SFF-8088 mini-SAS Yes
Low profile 4 Internal/4 External SAS and SATA x8 0, 1, 5, 6, 10, 50, Single Disk 512MB DDR2 533 SFF-8087/SFF-8088 mini-SAS Yes
Low profile 4 Internal SAS and SATA x8 0, 1, 5, 6, 10, 50, Single Disk 512MB DDR2 533 SFF-8087 mini-SAS Yes
2
3ware® 9650SE High Performance PCI Express to Serial ATA II RAID Controllers The best keeps getting better with red hot RAID 6 AMCC’s 3ware 9650SE SATA II hardware RAID controllers deliver industry-leading RAID 6 and RAID 5 performance, robust fault tolerance, and multi-terabyte capacities. A PCI Express host interface, Multi-lane™ connectivity, StorSwitch™ architecture, and sophisticated SATA II features drive this unrivaled performance.
3ware 9650SE Specifications • PCI Express x1, x4, x8 configurations • Serial ATA II advanced features — 3Gb/s transfer speed — Native Command Queuing • Low profile form factor — 2, 4, 8-port configurations • Full height form factor — 12, 16, 24-port configurations • RAID levels: 0, 1, 5, 6, 10, 50, Single Disk, JBOD (see chart below) • RoHS 6 of 6 and WEEE compliant 3ware 9650SE Series Selection Guide 9650SE-2LP
9650SE-4LPML
9650SE-4LPME
9650SE-8LPML
Form Factor Port Count Drive Interface PCI Express
Low profile 2 SATA x1
RAID Levels
0, 1, Single Disk, JBOD
Onboard Memory Connector Type BBU Support
128MB DDR2 533 Discrete No
Low profile 4 SATA x4 0, 1, 5, 10, Single Disk, JBOD 256MB DDR2 533 Multi-lane Yes
Low profile 4 SATA x4 0, 1, 5, 10, JBOD 256MB DDR2 533 Multi-lane (external) Yes
Low profile 8 SATA x4 0, 1, 5, 6, 10, 50, Single Disk, JBOD 256MB DDR2 533 Multi-lane Yes
SATA 9650SE-12ML
9650SE-16ML
9650SE-24M8
Full height 12 SATA x8 0, 1, 5, 6, 10, 50, Single Disk, JBOD 256MB DDR2 533 Multi-lane Yes
Full height 16 SATA x8 0, 1, 5, 6, 10, 50, Single Disk, JBOD 256MB DDR2 533 Multi-lane Yes
Full height 24 SATA x8 0, 1, 5, 6, 10, 50, Single Disk, JBOD 512MB DDR2 533 Multi-lane Yes
3ware® 9550SXU* High Performance PCI-X to Serial ATA II RAID Controllers High Performance PCI-X RAID Solution of Choice The 3ware 9550SXU SATA II RAID controller delivers performance, robust fault-tolerance, and multi-terabyte capacities. Combined with an advanced RAID management feature set that includes web-based, command-based, and API software components, the 9550SXU, available in 4, 8, 12, and 16-port configurations, is the most compelling PCI-X solution available.
3ware 9550SXU Specifications • • • • • •
PCI-X 1.0b (and PCI 2.3) compliant — 64-bit/133/100/66MHz bus master Serial ATA II advanced features — 3Gb/s transfer speed — Native Command Queuing Low profile (4 and 8-port) and full height form factors 4, 8, 12, and 16-port configurations RAID levels: 0, 1, 5, 10, 50, Single Disk, and JBOD (see chart below) RoHS 6 of 6 and WEEE compliant
3ware 9550SXU Series Selection Guide Form Factor Port Count Drive Interface Host Interface Host Interface Speed RAID Levels Onboard Memory Connector Type
SATA
9550SXU-4LP
9550SXU-8LP
9550SXU-12
9550SXU-12MI
Low profile 4 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, Single Disk, JBOD 128MB Discrete
Low profile 8 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, 50, Single Disk, JBOD 128MB Discrete
Full height 12 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, 50, Single Disk, JBOD 256MB Discrete
Full height 12 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, 50, Single Disk, JBOD 256MB Multi-lane
*A “U” has been added to all 9550SX part numbers to denote RoHS 6 of 6 compliance
9550SXU-12ML
9550SXU-16ML
Full height 12 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, 50, Single Disk, JBOD 256MB Multi-lane
Full height 16 SATA PCI-X 64-bit/133MHz 0, 1, 5, 10, 50, Single Disk, JBOD 256MB Multi-lane 3
3ware® Sidecar High-Performance Hardware RAID Storage for PC and Apple Workstations Think Outside the Box The 3ware® Sidecar featuring true hardware RAID is the only external storage choice for PCs, Apple® Mac Pro and Power Mac® G5 when capacity, performance, data protection, and ease of use are the goals. Broad OS support including Mac OS X, Windows, and Linux, an easily configurable RAID controller teamed with an intuitive management suite, and Multi-lane connectivity make the 3ware Sidecar as easy to use as 1-2-3.
3ware Sidecar Features
Operating System Support
• • • •
• • • • • •
High performance 4-port PCI Express to SATA II RAID controller for real hardware RAID — RAID levels 0, 1, 5, 10 and JBOD — 256MB DDR2 533 memory with ECC protection — BBU Support Complete configuration management suite — 3ware Disk Manager 2 (3DM®2) — Command Line Interface (CLI) 4-bay external Serial ATA desktop enclosure — Hot-swap and hot-spare support for easy maintenance — 4TB of external storage when loaded with 1TB drives (not included) — Front panel LED status indicators RoHS 6 of 6 and WEEE compliant (lead free)
Microsoft Windows 2003/XP/2000 (32/64-bit) Microsoft Windows Vista (32/64-bit) Red Hat Linux, SuSE Linux, Fedora Core (32/64-bit) Linux Kernels 2.4, 2.6 (32/64-bit) FreeBSD (32/64-bit) Mac OS X (G5: 10.4.6+, Mac Pro: 10. 4.8)
For complete OS listing, go to: www.3ware.com/support/OS-support
3ware Sidecar Minimum System Requirements • PC workstation, or Apple Mac Pro, or Apple Power Mac G5 • Available PCI Express slot (x4 minimum) • Supported operating system Note: Power Mac G5 with PCI-X is not supported
4,000 800,000 1,500,000 40,000,000
xSATA up to 28x FASTER! 1200 1050
xSATA offers significantly faster transfer speeds, better scalability, and improved cabling options than eSATA, FireWire and USB interfaces.
Interface
Interface Speed
xSATA eSATA FireWire 800 FireWire 400 USB 2.0
12Gb/s (1200MB/s) 3Gb/s (300MB/s) 800Mb/s (80MB/s) 400Mb/s (40MB/s) 480Mb/s (48MB/s)
Note: These interfaces use 8b/10b encoding
750 600 450 300 150
12Gb/s (1200MB/s)
xSATA vs. eSATA, FireWire and USB
MB / Second
900
480Mb/s (48MB/s)
Movies Digital Photos Songs Spreadsheets
800Mb/s (80MB/s)
Quantity
400Mb/s (40MB/s)
Movie=1GB Digital Photo=5MB Song=3MB Spreadsheet=100KB
Data
3Gb/s (300MB/s)
How Much is 4TB?
0 FireWire 400
FireWire 800
Interface Technology
xSATA has a TOTAL speed-matching bandwidth of 1.2GB/s (300MB/s X 4-lanes!) eSATA Solutions share the 300MB/s bandwidth among the available lanes (300MB/s ÷ 4 lanes) 4
Multi-lane™ High-Performance SAS and SATA Cable and Connector System Multi-lane Benefits
Get Connected via the Multi-lane™ Expressway AMCC’s award winning Multi-lane design enables highly reliable and streamlined enterprise-class SAS and SATA storage solutions by greatly reducing the number of cables needed to connect controllers, backplanes, and standard SAS/SATA drives. The Multi-lane SATA cable/connection system is fast, secure, simple, and clutter free. It combines the RAID controller’s multiple SAS/SATA ports into single locked connections. Multiple 3Gb/s lanes of SAS/SATA traffic travel through just one cable from the RAID controller to the system backplane or to multiple hard drives with a breakout cable.
• Multiple lanes of high speed SAS and/or SATA traffic through a single cable • Increased system reliability • Reduced cable count • Streamlined storage • Locked connections • Improved airflow
Multi-lane SAS and SATA Cable and Connector Systems SFF-8088 to SFF-8088
SFF-8088 to SFF-8470
SFF-8087 to SFF-8482
SFF-8087 to SFF-8087
SFF-8087 to Discrete
3ware Controller Model # 9690SA (-8E, -4I4E)
3ware Controller Model # 9690SA (-8E, -4I4E)
3ware Controller Model # 9690SA (-8I, -4I4E, 4I)
3ware order # CBL-SFF8088SAS-10M (1.0 m) CBL-SFF8088SAS-20M (2.0 m)
3ware order # CBL-SFF8088IB-10M (1.0 m) CBL-SFF8088IB-20M (2.0 m)
3ware order # CBL-SAS8087OCF-06M (0.6 m)
3ware Controller Model # 9690SA (-8I, -4I4E, 4I) 9650SE (-4LPML, -8LPML, -12ML, -16ML) 9550SXU (-12ML, 16ML)
3ware Controller Model # 9690SA (8I, 4I4E, 4I) 9650SE (-4LPML, -8LPML, -12ML, -16ML) 9550SXU (-12ML, -16ML)
3ware order # CBL-SFF8087-05M (0.5 m) CBL-SFF8087-06M (0.6 m)
3ware order # CBL-SFF8087OCF-05M (0.5 m) CBL-SFF8087OCF-06M (0.6 m) CBL-SFF8087OCF-10M (1.0 m)
(Multi-lane external SAS)
(Multi-lane external SAS converter cable)
(Forward SAS breakout cable w/ drive power connectors)
(Multi-lane internal)
(Forward breakout cable)*
Discrete to SFF-8087
SFF-8087 to SFF-8470
M8 to SFF-8087
M8 to Discrete
Discrete SATA
3ware Controller Model # 9550SXU (-4LP, -8LP, -12) 9500S-4LP
3ware Controller Model # 9650SE (-4LPML, -8LPML, -12ML, -16ML) 9550SXU (-12ML, -16ML) (SFF-8087 on controller)
3ware Controller Model # 9650SE-24M8
3ware Controller Model # 9650SE-24M8
3ware order # CBL-M8ML-06M (0.6 m)
3ware order # CBL-M8OCF-06M (0.6 m) CBL-M8OCF-10M (1.0 m)
3ware Controller Model # 9650SE-2LP 9550SXU (-4LP, -8LP, -12) 9500S-4LP 8006-2LP
(Reverse breakout cable)*
3ware order # CBL-SFF8087OCR-05M (0.5 m) CBL-SFF8087OCR-06M (0.6 m) CBL-SFF8087OCR-10M (1.0 m)
(Bi-directional Multi-lane hybrid cable)
3ware order # CBL-SFF8087IB-05M (0.5 m) CBL-SFF8087IB-06M (0.6 m)
(Multi-lane internal “Y” cable)
(Forward breakout cable)*
(Standard, point-to-point SATA cable)
3ware order # CBL-SATA-39 (39”/1 m)
Discrete to SFF-8470
SFF-8088 to SFF-8088
SFF-8470 to SFF-8087
SFF-8470 to SFF-8470
SFF-8470 to Discrete
3ware Controller Model # 9550SXU (-4LP, -8LP, -12) 9500S-4LP
3ware Controller Model # (3ware Sidecar)
3ware Controller Model # 9550SXU-12MI
3ware Controller Model #
9550SXU-12MI
3ware Controller Model # 9550SXU-12MI
3ware order # CBL-SFF8088-20M (2.0 m)
3ware order # CBL-SFF8087IB-05M (0.5 m) CBL-SFF8087IB-06M (0.6 m)
3ware order # CBL-IB-05M (0.5 m) CBL-IB-10M (1.0 m)
3ware order # CBL-OCF-18 (0.5 m) CBL-OCF-10M (1.0 m)
(Reverse breakout cable)*
3ware order # CBL-OCR-18 (0.5 m) CBL-OCR-10M (1.0 m)
*
(Multi-lane external)
(Bi-directional Multi-lane hybrid cable)
Breakout cables have a Multi-lane connector on one end and discrete connectors on the other end • Forward breakout cables have a Multi-lane connector on the controller end and discrete connectors to the drives • Reverse breakout cables have discrete connectors on the controller end and a Multi-lane connector to the backplane Note: Cable color may differ from colors shown
(Multi-lane internal)
(Forward breakout cable)*
5
3ware Controller/Cable Matrix Connector to Connector Options Controller
To Controller
To Drives / Backplane
Cable P/N Options
Cable Description
Where Used
3ware 9690SA SAS/SATA RAID Controllers
9690SA-8I
9690SA-8E
9690SA-4I4E
9690SA-4I
SFF-8087
SFF-8087
CBL-SFF8087-05M CBL-SFF8087-06M
0.5 meter cable 0.6 meter cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s Multi-lane SFF-8087 connector(s)
SFF-8087
SFF-8482
CBL-SAS8087OCF-06M
0.6 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four individual SAS or SATA drives; includes individual drive power connectors
SFF-8087
Discrete
CBL-SFF8087OCF-05M CBL-SFF8087OCF-06M CBL-SFF8087OCF-10M
0.5 meter forward breakout cable 0.6 meter forward breakout cable 1.0 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to the drives’ or backplane’s discrete SATA connector(s)
SFF-8088
SFF-8088 SFF-8470
SFF-8088
SFF-8088
SFF-8088
SFF-8470
SFF-8087
SFF-8087
1.0 meter cable 2.0 meter cable 1.0 meter cable (converter cable) 2.0 meter cable (converter cable) 1.0 meter cable 2.0 meter cable 1.0 meter cable (converter cable) 2.0 meter cable (converter cable) 0.5 meter cable 0.6 meter cable
Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s Multi-lane SFF-8088 connector(s)
SFF-8088
CBL-SFF8088SAS-10M CBL-SFF8088SAS-20M CBL-SFF8088IB-10M CBL-SFF8088IB-20M CBL-SFF8088SAS-10M CBL-SFF8088SAS-20M CBL-SFF8088IB-10M CBL-SFF8088IB-20M CBL-SFF8087-05M CBL-SFF8087-06M
SFF-8087
SFF-8482
CBL-SAS8087OCF-06M
0.6 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four individual SAS or SATA drives; includes individual drive power connectors
SFF-8087
SFF-8087
CBL-SFF8087-05M CBL-SFF8087-06M
0.5 meter cable 0.6 meter cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s Multi-lane SFF-8087 connector(s)
SFF-8087
SFF-8482
CBL-SAS8087OCF-06M
0.6 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four individual SAS or SATA drives; includes individual drive power connectors
SFF-8087
Discrete
CBL-SFF8087OCF-05M CBL-SFF8087OCF-06M CBL-SFF8087OCF-10M
0.5 meter forward breakout cable 0.6 meter forward breakout cable 1.0 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to the drives’ or backplane’s discrete SATA connector(s)
Discrete
Discrete
CBL-SATA-39
39” (1m) standard, discrete, point-to-point SATA cable
Connects a controller’s discrete SATA port(s) to the drives’ or backplane’s discrete SATA connector(s)
SFF-8087
SFF-8087
CBL-SFF8087-05M
0.5 meter cable
CBL-SFF8087-06M
0.6 meter cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s SFF-8087 Multi-lane connector(s)
CBL-SFF8087OCF-05M
0.5 meter forward breakout cable
SFF-8087
Discrete
CBL-SFF8087OCF-06M
0.6 meter forward breakout cable
CBL-SFF8087OCF-10M
1.0 meter forward breakout cable
CBL-SFF8087IB-05M
0.5 meter converter cable (internal hybrid)
CBL-SFF8087IB-06M
0.6 meter converter cable (internal hybrid)
Connects the controller’s SFF-8087 Multi-lane (ML) connector(s) to the backplane’s SFF-8470 Multi-lane (MI) connector(s)
CBL-M8ML-06M
0.6 meter “Y” cable
Connects the controller’s M8 Multi-lane connector(s) to the backplane’s SFF-8087 Multi-lane connector(s)
CBL-M8OCF-06M
0.6 meter forward breakout cable
CBL-M8OCF-10M
1.0 meter forward breakout cable
CBL-SFF8088-20M
2.0 meter cable
Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s Multi-lane SFF-8470 connector(s) Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s Multi-lane SFF-8088 connector(s) Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s Multi-lane SFF-8470 connector(s) Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s Multi-lane SFF-8087 connector(s)
3ware 9650SE Internal RAID Controllers
9650SE-2LP
9650SE-4LPML, -8LPML, -12ML, -16ML
SFF-8087
SFF-8470
M8
SFF-8087
M8
Discrete
9650SE-24M8
Connects the controller’s SFF-8087 Multi-lane connector(s) to the drives’ or backplane’s discrete SATA connector(s)
Connects the controller’s M8 Multi-lane connector(s) to the drives’ discrete SATA connectors
3ware 9650SE with External Connectivity (3ware Sidecar Only)
9650SE4LPME
SFF-8088
SFF-8088
Connects the controller’s SFF-8088 Multi-lane connector to the 3ware Sidecar’s SFF-8088 Multi-lane connector
6
Connector to Connector Options Controller
To Controller
To Drives / Backplane
Cable P/N Options
Cable Description
Where Used
3ware 9550SXU Internal RAID Controllers
9550SXU-4LP, -8LP, -12
9550SXU-12MI
9550SXU-12ML, 16ML
Discrete
Discrete
Discrete
SFF-8087
Discrete
SFF-8470
SFF-8470
SFF-8470
SFF-8470
Discrete
SFF-8470
SFF-8087
SFF-8087
SFF-8087
SFF-8087
Discrete
SFF-8087
SFF-8470
Discrete
Discrete
Discrete
SFF-8087
Connects the controller’s discrete SATA port(s) to the drives’ or backplane’s discrete SATA connector(s)
CBL-SATA-39
39” (1m) standard, discrete, point-to-point SATA cable
CBL-SFF8087OCR-05M
0.5 meter reverse breakout cable
CBL-SFF8087OCR-06M
0.6 meter reverse breakout cable
CBL-SFF8087OCR-10M
1.0 meter reverse breakout cable
CBL-OCR-18
0.5 meter reverse breakout cable
CBL-OCR-10M
1.0 meter reverse breakout cable
CBL-IB-05M
0.5 meter cable
CBL-IB-10M
1.0 meter cable
CBL-OCF-18
0.5 meter forward breakout cable
CBL-OCF-10M
1.0 meter forward breakout cable
CBL-SFF8087IB-05M
0.5 meter converter cable (internal hybrid)
CBL-SFF8087IB-06M
0.6 meter converter cable (internal hybrid)
CBL-SFF8087-05M
0.5 meter cable
CBL-SFF8087-06M
0.6 meter cable
CBL-SFF8087OCF-05M
0.5 meter forward breakout cable
CBL-SFF8087OCF-10M
1.0 meter forward breakout cable
CBL-SFF8087IB-05M
0.5 meter converter cable (internal hybrid)
CBL-SFF8087IB-06M
0.6 meter converter cable (internal hybrid)
Connects the controller’s SFF-8087 Multi-lane (ML) connector(s) to the backplane’s SFF-8470 Multi-lane (MI) connector(s)
CBL-SATA-39
39” (1m) standard, discrete, point-to-point SATA cable
Connects the controller’s discrete SATA port(s) to the drives’ or backplane’s discrete SATA connector(s)
CBL-SFF8087OCR-05M
0.5 meter reverse breakout cable
CBL-SFF8087OCR-06M
0.6 meter reverse breakout cable
CBL-SFF8087OCR-10M
1.0 meter reverse breakout cable
CBL-SATA-39
39” (1m) standard, discrete, point-to-point SATA cable
Connects the controller’s discrete SATA port(s) to the backplane’s SFF-8087 Multi-lane connectors Connects the controller’s discrete SATA connector(s) to the backplane’s SFF-8470 Multi-lane connector(s) Connects the controller’s SFF-8470 Multi-lane connector(s) to the backplane’s SFF-8470 Multi-lane connector(s) Connects the controller’s SFF-8470 Multi-lane connector(s) to the drives’ or backplane’s discrete SATA connector(s) Connects the controller’s SFF-8470 Multi-lane (MI) connector(s) to the backplane’s SFF-8087 Multi-lane (ML) connector(s) Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s SFF-8087 Multi-lane connector(s) Connects the controller’s SFF-8087 Multi-lane connector(s) to the drives’ or backplane’s discrete SATA connector(s)
3ware 9500S and 8006 Internal RAID Controllers
9500S-4LP
Connects the controller’s discrete SATA port(s) to the backplane’s SFF-8087 Multi-lane connectors
8006-2LP Discrete
Discrete
Connects a controller’s discrete SATA port(s) to the drives’ or backplane’s discrete SATA connector(s)
Internal SFF-8087 or M8
Multi-lane Quick Reference Chart Cable/connector
Controller P/N Suffix
Connectivity
Also Known as
SFF-8470
MI
Internal
InfiniBand
SFF-8087
ML
Internal
Mini SAS 4i, Mini SATA Internal, iPass
SFF-8088
ME
External
Mini SAS 4x, Mini SATA External, iPass
M8
M8
Internal
—
Backplane SFF-8087 or SFF-8470
External SFF-8088 Multi-lane SFF-8087 and M8 cables provide internal connectivity from the controller to drives or the backplane. Multi-lane SFF-8088 cables provide external connectivity from the controller to external enclosures.
7
Battery Backup Units
BBU-MODULE-03
BBU-MODULE-04
BBU Availability Features
BBU Availability Features
• • • • • • • •
•
Battery Mounting Option • •
Battery attaches directly to the BBU Control Module The BBU Control module mounts directly to the RAID controller
Includes all BBU-MODULE-03 features + Remote battery mounting capability for design flexibility
Battery Mounting Options • • •
Battery can attach to a BBU daughter card in various positions Battery can attach remotely to chassis wall, both internally and externally Remote mounting kit without battery available separately
Compatible RAID Controllers • • •
3ware 9690SA 3ware 9650SE 3ware 9550SXU
2 1
2
3
3
1
Maximum reliability with cached write data protection Missing Array Detection Write Journaling Dynamic Sector Repair Drive Power-On Reset Detection Extensive Drive Timeout Recovery Out of Band Signaling Retry Up to 72 hours of data protection in the event of power failure
2
3
1 1
• •
3ware 9650SE 3ware 9550SXU
3
2 1
2 1
2
3
3 1
2
3
2
3
3
3
1 1
1 3
3
2
3
1 1 2
2
1
3
1
1
2
1
Compatible RAID Controllers
2 2
2
3
2
3
Battery placement options
3ware RAID Controller Features and Benefits StorSwitch™ Non-blocking switch fabric architecture
Maximizes controller throughput by allowing concurrent communications with all attached SATA drives through a pool of 32 direct memory access (DMA) channels.
Performance
StorSave Powerful reliability enhancements
Achieves unmatched data protection while maximizing performance in critical RAID modes when data availability, accessibility, and data protection are most needed.
Data Protection
StreamFusion Intelligent cache algorithm
Maximizes application performance under heavy loads by dynamically allocating controller cache for maximum bandwidth
Performance
Multi-lane™ Award-winning connector system
Dramatically increases subsystem reliability by radically reducing cable count and improves airflow
RAID 6 (On select 3ware 9690SA and 9650SE controllers)
Two sets of parity are simultaneously calculated, written, and rotated across all the drives. This allows the array to survive up to two drive failures without losing data, for significantly improved fault tolerance.
Advanced Content Streaming (9690SA and 9650SE Controllers)
Aggressively Caches write and read data and improves write and read content streaming. Provides intelligent caching algorithms to improve application performance in real world cases.
Hybrid Initialization (9690SA and 9650SE Controllers)
Faster foreground initialization for RAID 5 and RAID 6 arrays with 16 or more drives. Fastest background initialization for newly created arrays.
Array Availability and Performance
Accelerated RAID Recovery (9690SA and 9650SE Controllers)
Faster rebuild completion. Shorter verify/initialization.
Data Accessibility and Availability
Reliability & Convenience Data Protection Application Performance
8
Putting the Pieces Together Advanced 3ware RAID Features and Performance Architecture
StreamFusion Performance vs. Competition
Host Data
StorSwitch maximizes controller throughput — StorSwitch is a unique non-blocking switch fabric architecture that allows 3ware controllers to concurrently communicate to all attached SATA Disk #1 Disk #2 Disk #3 Disk #4 Disk #5 drives through a pool of 32 direct memory access (DMA) channels for unparalleled performance Block 1 P1 Parity Q1 Parity Block 2 Block 3 and data availability. The result is superior overall system performance compared to non-scalable P2 Parity Q2 Parity Block 5 Block 6 Block 4 hub-based systems that share the bandwidth of a single DMA channel. Block 8
P3 Parity Block 12
Block 11
Block 10
Q3 Parity
Disk #1
Disk #2
Disk #3
Disk #4
B
C
D
E
F
G
H
Disk #5
AMCC Competition 1
40 20
A0
B0
C0
0 Parity
A1
B1
1 Parity
D1
A2
0
StorSave optimizes data protection and performance — StorSaves’s revolutionary combination of powerful reliability enhancements and a battery backup unit (BBU) maximize data protection and system reliability without sacrificing controller performance. StorSave permits 3ware controllers to use both controller cache and disk cache during SATA RAID operations. This strengthens array performance during optimal usage, as well as during degraded RAID 5 and RAID 6 operations which Host Data means faster rebuild times. StorSave Profiles allow user-specified levels of protection vs. performance RAID 0 “Striping” (9690SA, 9650SE, 9590SE and 9550SXU only). Host Data A
RAID 5 “Rotational Parity”
60
Striped Data with Distributed Double Parity — RAID 6
C2
2 Parity
2 B3
13 Parity
4
Competition 2
D2
C3
8
# Streams
D3
16
SATA Disk
V36OA60A/64KB stripes/RAID 5/all other settings at default
Block 12
P4 Parity
A
Striped Data with Distributed Double Parity — RAID 6
Disk #1
Disk #2
Disk #3
Disk #4
Disk #5
=
B
120
1 Parity
D1
B
A2
2 Parity
C2
D2
3 Parity
B3
C3
D3
Block 2
Block 3
SATA Disk
Block 5
Block 6
SATA Disk
Block 8
P3 Parity
Q3 Parity
Block 9
Block 12
Block 11
Block 10
P4 Parity
RAID 0 “Striping”
Q4 Parity
RAID 0, 1, 5, 10 and JBOD
3 Parity
2 Parity
C2
D2
B3
C3
D3
RAID 1 “Mirroring”
B
C
D
E
F
G
H
D H
• Applications K requiringL high bandwidth A performance but no fault tolerance ETC. . . N O B • Video production/editing C • Pre-press applications
A
B
C
E
F
G
M
I
J
K
N
D1
A
I
M
0 Parity
A2
Striped Data with Distributed Double Parity — RAID 6
RAID 0 “Striping”
C0
L
O
=
A
C
B1
D
E I M
B
C
F
G
H B0
C0
0 Parity
B1
1 Parity ETC. . .
D1
A2
2 Parity
C2
D2
3 Parity
B3
C3
D3
J N
A0
A
A1
K O
L
Hardware vs. Software RAID
=
SATA Disk
C
Drive 0
SATA Disk D1
D2
• Accounting D1 1 • Payroll Drive 1 • Financial 1
Mirror
Stripe
D1
D1 1
Drive 0
Drive 1
D2
D2 1
Drive 2
Drive 3
D2
D2 1
Drive 2
Drive 3
D2
Drive 3
RAID 10 "Striped Mirror"
A1
• Most versatile RAID level providing performance, B B1 fault tolerance and storage efficiency C C1 • Video production/editing 1 D • File and applicationsD servers • Database servers • Email servers SATA Disk • News servers SATA Disk • Internet/Intranet
B
SATA D1 Disk 1
Drive 2
RAID 1 “Mirroring”
D
Mirror
RAID 10 "Striped Mirror" • Provides fault tolerance and a read speed SATA Disk D1 D1 1 A 1 Mirror advantage over non-RAID disks Drive 0 Drive 1 Stripe requiring SATA Disk 1 • Applications high availability
C1
RAID 5 “Rotational Parity” A
=
Stripe
D1
RAID 10 "Striped Mirror"
RAID 1 “Mirroring”
1
A
D
ETC. . .
RAID 0 “Striping”
SATA Disk
B
J
16
SATA Disk
Block 1
1 Parity
Competition 2
SATA Disk
Q2 Parity
B1
Competition 1
SATA Disk
P2 Parity
B0
AMCC
SATA Disk
Q1 Parity
A1
D2 1 Drive 3
Iometer 2004.07.30dual Xeon 2.6 Ghz/1GB system/WinXP SP2/HDS7222525VLSA80/fw SATA Disk V36OA60A/64KB stripes/RAID 5/all other settings at default
Block 4
A0
D2 Drive 2
1
P1 Parity
Common RAID Levels
Drive 1
Stripe
1
StreamFusion assures scalable high performance
RAID 5 “Rotational Parity”
Block 7
D1 1
D1
A1
StreamFusion Performance vs. Competition Drive 0
B1
Q4 Parity
SATA Disk
"Striped • Protects drive and controller cached writesRAID in the10event of aMirror" power loss RAIDcontroller 1 “Mirroring” • Uses and drive write cache in all modes Mirror • Dual caching for faster rebuild times
1
Block 11
SATA Disk
I/O
StreamFusion maximizes application performance under multiple loads — An I J K intelligent L C C 100 RAID 5 “Rotational Parity” ETC. . . D StreamFusion in Action cache algorithm dynamically optimizes RAID 5 and RAID accesses and manages N 3 efficiently O D Block 1 6 diskBlock P1 Parity Q1 Parity 2M Block 80 #1 Disk #2 Disk #3 for guaranteed Disk #4 Disk #5 dataDisk through controller cache bandwidth. As the number of data streams increases, 60 P2 Parity Q2 Parity Block 5 Block 6 Block 4 5 “Rotational Parity”A0 B0 C0 0 Parity the total bandwidth is divided equally among them. Application performance will not RAID suffer 40 Q3 Parity Block 9 Block 1 Block 7Block 2 Block 8Block 3 P3 Parity P1 Parity Q1 Parity B1 A1 20 1 Parity D1 during heavy traffic or when multiple applications are accessing data simultaneously. 3ware RAID P4 Parity Q4 Parity Parity Q2 Parity Block 10Block 5 Block 11Block 6 Block 12 Block 4 controllers are the performance bottleneck, as is often the case with softwareARAID and B0 HostP2not Data A2 00Parity 2 Parity C2 D2 0 C0 1 2 4 8 # Streams Block 8 controllers. P3 Parity Q3 Parity BlockDistributed 9 7 otherBlock hardware RAID Striped Data with Double Parity — RAID 6 3 Parity D3 B3 C3 Block 10
I/O
I/O StreamFusion assures scalable high performance SATA Disk Iometer 2004.07.30dual Xeon 2.6 Ghz/1GB system/WinXP SP2/HDS7222525VLSA80/fw I/O
A1
•
Data is first mirrored, then striped across across the drives to provide double drive failure protection without the parity calculation performance penalty of RAID 5 and RAID 6. The mirror provides the redundancy.
• Ability to recover from a drive failure in either mirrored set
JBOD = Just a Bunch of Disks JBOD refers to an unconfigured disk attached to a RAID controller • No fault tolerance
SATA Disk All AMCC 3ware RAID controllers incorporate onboard processors to deliver true hardware RAID. Software RAID schemes use the system’s processor, exploit host memory, compromise reliability and potentially rob the system of as much as 60% of its CPU cycles just to process RAID calculations.
RAID 10 "Striped Mirror"
RAID 1 “Mirroring”
Mirror
Hard Drive
3ware SATA Hardware RAID Controller
StreamFusion in Action
80
Q4 Parity
Hard Drive
Advanced StorSwitch Architecture
100
Block 9
P4 Parity
Hard Drive
120
™
Block 7
Hard Drive
Up to 1.5 Gb/sec per port
9
Host Data
Red Hot RAID 6 The fastest RAID 6 available RAID 6 eliminates the risk of data loss if a second hard disk drive fails while the RAID array is rebuilding. In a 3ware RAID 6 system, two sets of parity are calculated, written, and rotated across all the drives. This second simultaneous P + Q parity calculation allows the array to survive up to two drive failures without losing data, for significantly improved fault tolerance. RAID 6-enabled 9690SA and 9650SE controllers deliver unequaled RAID 6 performance.
RAID 6 represents a sea change in the RAID landscape. It provides the industry with higher levels of data protection, data availability and fault tolerance than RAID 5. By assuring data availability following a second drive failure, users can rest assured that they are enjoying maximum data protection, both in normal and degraded modes. And, with RAID 6-enabled 3ware controllers, RAID 6 will not cripple performance.
Disk #1
Disk #2
Disk #3
Disk #4
Disk #5
P1 Parity
Q1 Parity
Block 1
Block 2
Block 3
Block 4
P2 Parity
Q2 Parity
Block 5
Block 6
Block 7
Block 8
P3 Parity
Q3 Parity
Block 9
Block 10
Block 11
Block 12
P4 Parity
Q4 Parity
Striped Data with Distributed Double Parity — RAID 6
3ware RAID 6: Two sets of parity data, P + Q, are striped across disks. RAID 6 safeguards against data loss during rebuild mode by allowing up to two consecutive drive failures for maximum fault tolerance.
RAID 6 Enabled 3ware Controllers • 9690SA-8I
• 9650SE-8LPML
RAID 6 is recommended for:
• 9690SA-8E
• 9650SE-12ML
• 9690SA-4I4E
• 9650SE-16ML
• High capacity systems with eight or more high capacity drives
• 9690SA-4I
• 9650SE-24M8
• Enterprise/mission critical installations
3ware RAID Controller Part Number Matrix 3ware 9690SA SAS/SATA Hardware RAID Controllers Model Number
Host Interface
Ports
9690SA-8I 9690SA-8E 9690SA-4I4E 9690SA-4I
PCI Express x8 PCI Express x8 PCI Express x8 PCI Express x8
8 Internal 8 External 4 Internal/4 External 4 Internal
RAID Levels
Controller Connector
Footprint
RoHS
0, 1, 5, 6, 10, 50, Single Disk 0, 1, 5, 6, 10, 50, Single Disk 0, 1, 5, 6, 10, 50, Single Disk 0, 1, 5, 6, 10, 50, Single Disk
SFF-8087 mini-SAS SFF-8088 mini-SAS SFF-8087 / SFF-8088 mini-SAS SFF-8087 mini-SAS
Low profile Low profile Low profile Low profile
6/6 6/6 6/6 6/6
3ware 9650SE PCI Express-to-Serial ATA II Hardware RAID Controllers Model Number
Host Interface
Ports
9650SE-2LP 9650SE-4LPML 9650SE-4LPME 9650SE-8LPML 9650SE-12ML 9650SE-16ML 9650SE-24M8
PCI Express x1 PCI Express x4 PCI Express x4 PCI Express x4 PCI Express x8 PCI Express x8 PCI Express x8
2 4 4 8 12 16 24
RAID Levels
Controller Connector
Footprint
RoHS
0, 1, Single Disk, JBOD 0, 1, 5, 10, Single Disk, JBOD 0, 1, 5, 10, JBOD 0, 1, 5, 6, 10, 50, Single Disk, JBOD 0, 1, 5, 6, 10, 50, Single Disk, JBOD 0, 1, 5, 6, 10, 50, Single Disk, JBOD 0, 1, 5, 6, 10, 50, Single Disk, JBOD
Discrete Multi-lane (SFF-8087) Multi-lane (SFF-8088) Multi-lane (SFF-8087) Multi-lane (SFF-8087) Multi-lane (SFF-8087) Multi-lane custom hybrid
Low profile Low profile Low profile Low profile Full height Full height Full height
6/6 6/6 6/6 6/6 6/6 6/6 6/6
3ware 9550SX PCI-X-to-Serial ATA II Hardware RAID Controllers Model Number
Host Interface
Ports
9550SXU-4LP 9550SXU-8LP 9550SXU-12 9550SXU-12MI 9550SXU-12ML 9550SXU-16ML
64-bit/133MHz 64-bit/133MHz 64-bit/133MHz 64-bit/133MHz 64-bit/133MHz 64-bit/133MHz
4 8 12 12 12 16
RAID Levels
Controller Connector
Footprint
RoHS
0, 1, 5, 10, Single Disk, JBOD 0, 1, 5, 10, 50, Single Disk, JBOD 0, 1, 5, 10, 50, Single Disk, JBOD 0, 1, 5, 10, 50, Single Disk, JBOD 0, 1, 5, 10, 50, Single Disk, JBOD 0, 1, 5, 10, 50, Single Disk, JBOD
Discrete Discrete Discrete Multi-lane (SFF-8470) Multi-lane (SFF-8087) Multi-lane (SFF-8087)
Low profile Low profile Full height Full height Full height Full height
6/6 6/6 6/6 6/6 6/6 6/6
10
3ware 9500S PCI-to-Serial ATA Hardware RAID Controllers Model Number
Host Interface
9500S-4LP
32/64-bit/66MHz
Ports
4
RAID Levels
Controller Connector
Footprint
RoHS
0, 1, 5, 10, Single Disk, JBOD
Discrete
Low profile
5/6
RAID Levels
Controller Connector
Footprint
RoHS
0, 1, JBOD
Discrete
Low profile
5/6
3ware 8006 PCI-to-Serial ATA Hardware RAID Controller Model Number
Host Interface
Ports
8006-2LP
64-bit/66MHz
2
3ware Controller Specifications
3ware Controller Accessories
Operating Systems
Model Number
Description
BBU-MODULE-03 BBU-MODULE-04
Battery Backup Unit for 3ware 9650SE/9590SE/9550SX(U) Battery Backup Unit for 3ware 9690SA/9650SE/9590SE/9550SX(U); Includes remote battery mounting kit Replacement battery for BBU-MODULE-03 and BBU-MODULE-04 Battery Backup Unit for 3ware 9500S Replacement battery for BBU-9500S-01 SATA internal drive cage SATA drive tray (to be used with the RDC-400-SATA) Spare drive tray for 3ware Sidecar Please reference the cable datasheet
PCI Compliance Serial Interface RAID Features
SCSI Features SATA II Features Kit Contents
Warranty Support
Microsoft® Windows® 2003/XP/2000, Red Hat Linux, SuSE Linux, Fedora Linux, 2.4 Linux kernel, 2.6 Linux kernel, FreeBSD, 32/64-bit support, Mac OS X (10.4.6 and above) For complete OS listing, go to: www.3ware.com/support/OS-support PCI Express 1.1, PCI-X 1.0b, and PCI 2.3 compliant (64-bit/133/100/66MHz bus master) SATA and SATA II (1.5/ 3Gb/s), and SAS RAID 6 on select 3ware 9650SE controllers, RAID Level Migration, online capacity expansion, hot swap/hot spare, S.M.A.R.T. disk drive monitoring, multiple card support, multiple logical volumes and RAID levels, remote management, alert notifications and more Scatter/gather, command queuing, command reordering, elevator seek, dynamic sector repair, background media scanning and more 3Gb/s, Native Command Queuing, OOB Staggered Spin-up (compliant with the SATA 2.6 specification) SAS/SATA II/SATA RAID controller and cables, CD including driver, 3ware Disk Manager 2 (3DM®2), Command Line Interface (CLI), User Guide, Printed Installation Documentation 3 years Free technical support, advanced replacement option
BATT-SPARE-02 BBU-9500S-01 BATT-9500S-SPARE RDC-400-SATA RDC-TRAY-SATA RDE-TRAY-01 CABLES
Worldwide 3ware Distributors and Sales Offices 3ware Distributors North America Bell Micro (US and Canada) www.bellmicro.com Synnex (US and Canada) www.synnex.com D&H (US) www.dandh.com Latin America Bell Micro www.bellmicro.com/latinamerica Europe, Middle East and Africa Asbis www.asbis.com Avnet www.avnet.com Bell Micro www.bellmicro.eu.com
Hammer www.hammerplc.com CTT www.ctt.de TMC www.tmc-uk.com
3ware Sales Offices Company Headquarters (USA) 215 Moffett Park Drive Sunnyvale, CA 94089 Tel: +1-408-542-8771 +1-877-883-9273 Email: 3waresales@ amcc.com www.3ware.com
Asia Pacific APT (China) www.apt-storage.com ASK (Japan) www.ask-corp.co.jp Digicor (Australia) www.digicor.com.au
Europe +44-1494-890700 Asia/Pacific +65-6826-3381 China +86-10-6581-4916
Epecom Graphics (Singapore) www.epecomgraphics.com.sg Synnex K.K. (Japan) www.synnex.co.jp THC (China) www.thcsy.com Upmost Technology Corp. (Taiwan) www.upmost.com.tw 11
Spring/Summer 2008
3ware® Produc t Guide H A R D W A R E
R A I D
C O N T R O L L E R S
Sales Offices for 3ware Products: 215 Moffett Park Drive Sunnyvale, CA 94089 Tel: +1-408-542-8771 +1-877-883-9273 Email:
[email protected] www.3ware.com
Europe: +44-1494-890700 Asia/Pacific: +65-6826-3381 China: +86-10-6581-4916
AMCC reserves the right to make changes to its products, or to discontinue any product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the information being relied upon is current. For the latest 3ware product information, visit www.3ware.com. AMCC is a registered trademark of Applied Micro Circuits Corporation. 3ware, 3DM and StorSwitch are registered trademarks of Applied Micro Circuits Corporation in the United States. All other trademarks are the property of their respective holders. Copyright © 2008 Applied Micro Circuits Corporation. All Rights Reserved. FamPG_031908