FarReach™ Drill Pipe 4-1/2" SPECIFICATIONS
Drill Pipe Dimensions and Materials Pipe Body New Premium OD (in) 4.600 4.400 Wall Thickness (in) 0.500 0.400 Wear Band Diameter (in) 4.600 Remaining Body Wall (%) 100.0% 80.0% Reduction in OD (%) 0.0% 4.3% ID (in) 3.600 3.600 Alloy / Temper 2014-T6 Yield Strength (ksi) 58 Modulus (msi) 10.6 Cross Sectional Area (in^2) 6.440 5.027 Tool Joint NC50 Connection New Premium OD (in) 6.125 5 24/32 ID (in) 3.340 3.340 Box Tong Length, Lb (in) 11.875 Pin Tong Length, Lp (in) 7.375 Yield Strength (ksi) 120 Drill Pipe Assembly Data Open Displacement Shoulder to Shoulder Length (ft) 30.00 (US gal/ft) Closed Displacement Approximate Weight (lb) 340 (US gal/ft) Adjusted Weight (lb/ft) 11.34 Capacity (US gal/ft) Drill Pipe Mechanical Performance Pipe Body New Premium Tensile Strength (lbf) 374,000 292,000 Torsional Strength (ft-lbf) 33,300 25,700 80% Torsional Strength (ft-lbf) 26,600 20,600 Collapse Pressure (psi) 11,700 9,080 Internal Yield Pressure (psi) 11,000 10,500 Tool Joint New Premium Tensile Strength (lbf) 1,200,000 776,000 Torsional Strength (ft-lbf) 38,000 20,600 Recommended Make-Up Torque (ft-lbf) 22,800 12,400 Balanced OD (in) 6.34 6.34 Torsional Ratio TJ/Pipe 1.14 0.800
Class 2 4.300 0.350 70.0% 6.5% 3.600
4.343
Class 2 5 22/32 3.340
0.40 0.94 0.54
Class 2 252,000 22,100 17,700 7,600 9,440 Class 2 705,000 17,700 10,600 6.34 0.800
Alcoa FarReach™ Drill Pipe delivers the industry’s
This lightweight, high-strength combination allows
highest strength-to-weight ratio, improved hydraulic
for drilling to much greater depths and distances
performance, optimized wear characteristics, and a
with existing drilling equipment. Find out more
high level of corrosion resistance.
about FarReach™ and how it can help your
FarReach™ Drill Pipe enables extending the reach
operation go farther, starting today.
of your operation in deepwater, horizontal drilling and other Extended Reach Drilling (ERD) applications.
Drill Pipe Mechanical Performance Notes: (1) Tensile strength based on minimum yield strength. (2) Torsional strength based on shear strength equal to 57.7% of minimum yield strength. (3) Collapse pressure calculated per ISO/DIS 20312. (4) Internal yield pressure calculated per API Bullentin 5C3 which includes a 12.5% knockdown for new pipe. (5) Performance calculated with frictional factor and safety factor of 1.0.
For more information on how Alcoa can help you leverage high strength-to-weight aluminum alloy (6) All data based on nominal dimensions and calculated per standard methods unless otherwise noted. technology, visit AlcoaOilandGas.com. (7) Pipe properties base on pipe dimensions (non-upset area). (8) These data are intended for a preliminary evaluation of this configuration.
© 2013 Alcoa Oil & Gas. All rights reserved.
AO1152
1013