4 Remote I/o

   EMBED


Share

Transcript

4 Remote I/O Digital Output Module 8-Channel Version Type 9475/.2-08-.. from Rev. F ● 8 channels for Ex i solenoid valves, piezo and booster-valves ● Intrinsically safe Ex ia IIC outputs ● Additional input for „Plant-STOP“ available (acc. to IEC 61508 up to SIL 2) ● Galvanic isolation between outputs and system ● Open-circuit and short-circuit monitoring for each field circuit ● Connection of the field cables with plug-in terminals ● Modules can be replaced while powered up (hot swap) ● Installation in – Zone 1 and Zone 2 – Zone 21 and 22 Zones 0 1 2 20 21 22 09729E00 The outputs are short circuit protected. All channels are individually monitored for open- and short-circuits. Monitoring can be switched off individually in each channel using parameters. Open-circuit monitoring is also active when the switching state is OFF. The interface of the Digital Output Module with the internal data bus of the BusRail is designed with redundancy. Modules 9475/22-08-.1 are equipped with an additional Ex i digital input for simultaneous deactivation of all outputs of a module („Plant-STOP“). This meets the requirements on functional safety as per IEC 61508 up to SIL 2. Ex i interfaces Installation in X X X X X X X X X X X1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 . . . 06306E00 4/1 Automation 17.04.2008 4 Digital Output Module 8-Channel Version Type 9475/.2-08-.. from Rev. F Selection Table Version Digital Output Module Channels 8 Safety data Ex ia IIC Digital Input (Plant-STOP) Order number Weight max. voltage Uo max. current Io kg 11.5 V 75 mA no 9475/12-08-41 0,275 19.9 V 145 mA no 9475/12-08-51 0,275 26.2 V 107 mA no 9475/12-08-61 0,275 19.9 V 145 mA yes 9475/22-08-51 0,275 26.2 V 107 mA yes 9475/22-08-61 0,275 Technical Data Certificates PTB 99 ATEX 2220 Other certificates IECEx, USA (FM), Canada (CSA), Russia (CTB), Shipping (DNV, GL, ABS) Explosion protection Gas explosion protection E II 2 (1) G EEx ib [ia] IIC/IIB T4 Dust explosion protection E II (1/2) D [Ex iaD/ibD] Safety data for digital outputs Ex ib Type Uo [V] Io [mA] Po [mW) Lo [mH] IIC Co [nF] IIB IIC IIB 9475/12-08-41 11.5 50 216 2 2 610 3600 9475/12-08-51 19.9 38 558 1 1 110 860 26.2 30 565 0.5 0.5 79 490 9475/22-08-51 9475/12-08-61 9475/22-08-61 The effective internal capacitances and inductances are negligibly small Ex ia Type Uo [V] Io [mA] Po [mW) Lo [mH] IIC Co [nF] IIB IIC IIB 9475/12-08-41 11.5 75 216 6.70 25 1640 11200 9475/12-08-51 19.9 145 719 1.44 7.47 223 1420 26.2 107 697 1.57 9.75 97 750 9475/22-08-51 9475/12-08-61 9475/22-08-61 The effective internal capacitances and inductances are negligibly small Safety data for digital input for deactivating all outputs ("Plant-STOP") Ex ia only type Uo [V] Io [mA] Po [mW) Lo [mH] 9475/22-08-51 6.6 67 110 Co [nF] IIC IIB IIC IIB 8.24 31.4 22 500 9475/22-08-61 The effective internal capacitances and inductances are negligibly small Further information Automation 17.04.2008 see certificates 4/2 4 Digital Output Module 8-Channel Version Type 9475/.2-08-.. from Rev. F Technical Data Functional safety (IEC 61508) Digital input "Plant-STOP" Test report Exida FMEDA Stahl 03/05-19R001 max. SIL 2 Safe state all outputs "OFF" Safe Failure Fraction SFF 85,8 % (Typ A) MTBF (to SN 29500) 38 years (at 40 °C) PFDAVG at T[Proof] T[Proof] PFDAVG Further information 1 year 1.53 x 5 years 10-4 7.67 x 10 years 10-4 1.53 x 10-3 see test report Galvanic transmission between power supply and system components 1500 V AC between two input / output modules 500 V AC between inputs/outputs and system components 500 V AC The outputs and the input "Plant-STOP" of an I/O module have a common minus conductor Ex i outputs Type No-load voltage [V] U [V) I [mA] Ri [Ω] 9475/12-08-41 9.8 4.3 30 182 9475/12-08-51 17.4 12.7 29 163 23.1 17.4 20 287 9475/22-08-51 9475/12-08-61 9475/22-08-61 Number of channels 8 Output characteristics 9475/.2-08-41 9475/.2-08-51 09682E00 9475/.2-08-61 09683E00 09684E00 Digital input; Ex i 4/3 Function for deactivating all outputs ("Plant-STOP"), only type 9475/22-08-51, 9475/22-08-61 Supply voltage 5V Internal resistance 1.6 kO max. voltage for outputs in normal operating mode 1V min. voltage for all deactivated outputs ("Plant-STOP") 3.5 V Automation 17.04.2008 4 Digital Output Module 8-Channel Version Type 9475/.2-08-.. from Rev. F Technical Data Settings Open-circuit and short-circuit monitoring ON, ON without test current, OFF Output safety position during communication faults ON, OFF, hold last value Diagnostics Retrievable parameters Manufacturer, type, version, serial number Module faults • • • • • • Internal primary bus fault Internal redundant bus fault no response Dissimilar module configuration Hardware fault Hardware deactivation of outputs (via Systems OFF) Signal fault Open-circuit 9475/..-..-41 9475/..-..-51 9475/..-..-61 > 10 kO > 12 kO > 13 kO Short circuit < 95 O Terminal voltage for non-linear loads >4V Power supply Behavior with undervoltage All outputs are switched to the "OFF" status Typical power consumption Type all outputs short-circuited 9475/12-08-41 5.3 W 9475/12-08-51, 9475/22-08-51 6.2 W 9475/12-08-61, 9475/22-08-61 6.4 W Typical power loss Type all outputs short-circuited 9475/12-08-41 5.3 W 9475/12-08-51, 9475/22-08-51 6.2 W 9475/12-08-61, 9475/22-08-61 6.4 W Construction setup Module enclosure Polyamide 6GF Fire protection class (UL 94) HB Degree of protection (IEC 60529) Modules IP 30 Connections IP 20 Electrical connections Ex i field signals Plug-in terminals 16 pin with catch, 2.5 mm2, screw or connectors Display and operating interface Operation LED green "RUN" Failure LED red "ERR" Installation conditions Mounting type on 35 mm DIN rails NS 35/15 Mounting position horizontal or vertical Automation 17.04.2008 4/4 4 Digital Output Module 8-Channel Version Type 9475/.2-08-.. from Rev. F Technical Data Ambient conditions Ambient temperature - 20 °C ... + 65 °C Storage temperature - 40 °C ... + 70 °C Maximum relative humidity 95 % (no condensation) Vibration sinusoidal (IEC 60068-2-6) 1 g in frequency range 10 ... 500 Hz 2 g in frequency range 45 ... 100 Hz semi-sinusoidal (IEC 60068-2-27) 15 g (3 shocks per axis and direction) Electromagnetic compatibility Tested under the following standards and regulations: EN 61 326-1 (1998) IEC 1000-4-1...6, NAMUR NE 21 Note You will find a list of compatible I.S. solenoid valves, indicating lamps etc on our homepage www.stahl.de. Accessories and Spare Parts Designation Illustration Description mm2 Plug-in Terminal 02079E00 02077E00 Labeling strips Order number 2.5 with catch, 16 pin, screw connection, blue, for connecting the field signal to I/O modules, for instrinsically safe field circuits Designation: 1 ... 16 Attention: For I/O module type 9470 and 9480 an additional terminal is necessary. Designation: 17 ... 32 9490004670 2.5 mm2 with catch, 16 pin, spring connection, blue, for connecting the field signal to I/O modules, for intrinsically safe field, with test jacks Designation: 1 ... 16 Attention: For I/O module type 9470 and 9480 an additional terminal is necessary Designation: 17 ... 32 9490002670 „FB No ... Mod No ...“ for plug-in terminals, sheet with 26 labels 9490904850 „Only clean modules with damp cloths“ 9490906850 for I/O module labels; 6 labels each sheet; print-out with IS Wizard software; packaging unit = 20 sheets 9491001850 For installation between intrinsically safe and non-intrinsically safe connectors of the I/O-modules. With this, the required 50 mm distance is achieved. 9490901540 05869E00 Warning sign 05872E00 DIN4 sheet 09900E00 Partition 02078E00 4/5 Automation 17.04.2008 4 Digital Output Module 8-Channel Version Type 9475/.2-08-.. from Rev. F Dimension drawings (all dimensions in mm) - subject to alterations 09879E00 We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustrations cannot be considered binding. Automation 17.04.2008 4/6