Transcript
BVD-405x OPERATING INSTRUCTION
Doorstation BVD-405х is intended for operation in VIZIT doorphones / video doorphones (Series Comfort). The following models are available: - BVD-405А-2 - doorstation to connect 2 apartment handsets UKP; - BVD-405А-4 - doorstation to connect 4 apartment handsets UKP; - BVD-405СP-2 - video doorstation with colour camera to connect 2 video monitors; - BVD-405СP-4 - video doorstation with colour camera to connect 4 video monitors. Abbreviations used in the model names: A - No camera; С - Colour camera; P - Pinhole lens. BVD-405CP-4, BVD-405А-4
BVD-405CP-2, BVD-405А-2
1 Colour camera (BVD-405CP-2(4))
2 IR LEDs (illumination for camera in BVD-405CP-2(4))
1
3 Niche for nameplate
2
3
4 Speaker 5 CALL button for Apartment 4
9
6 CALL button for Apartment 3 7 CALL button for Apartment 2
4
8 7 6 5
8 CALL button for Apartment 1 9 Microphone
Figure 1 - Doorstation BVD-405x
FEATURES Individual CALL button for subscribers Beep in the doorstation and monitor / apartment handsets when the CALL button is pressed. Duplex intercom Door zone video monitoring (BVD-405CP-2 and BVD-405CP-4) Remote door unlocking by pressing the button on the monitor / apartment handset during intercom Beeps to indicate door lock release IR illumination for the camera (BVD-405CP-2 and BVD-405CP-4) Lighting for the nameplate Subscriber devices are VIZIT® trademarked products: - apartment handsets UKP; - video monitors VIZIT-М of Series 400. SAFETY INSTRUCTIONS The product does not contain voltage above 25 V. Do not make any connections or repair when the power is on. Take care not to spill any liquids or chemically active substances on the product. Switch the power off before cleaning the product. Clean by wiping with dry soft cloth. Do not use any liquid cleaners, aerosol cleaners or abrasive agents. 1/11 www.vizit.eu
OPERATING INSTRUCTION
BVD-405x
PARTS LIST
x1
x1
Doorstation BVD-405х
Skew Base
x1
x1
Blank nameplate
Operating Instruction Fasteners
for doorstation BVD-405х and skew base
x2
x4 Gag
Screw М4х16
x2
x2
Screw - 4х40
Anchor
INSTALLATION ORDER The doorstation is mounted on a wall near your entrance door. The skew base provides 20° turn and allows either leftside or right-side mounting. To protect the doorstation against sun, rain or snow, installation of specially designed Mounting Kit MK-405 is recommended. Installation order of the doorstation together with its sun/rain shield is described in the Mounting Kit MK-405 installation manual. 2
3
5 4 6 7
1
1 Doorstation
4 Hole (х2)
2 Skew base
6 mm in diameter 40 mm deep 5 Anchor (х2) 6 Screw - 4х40 (х2) 7 Gag (х2)
3 Screw М4х16 (х2)
Fasteners are supplied. Figure 2 - Doorstation wall-mounting on the left from the entrance door www.vizit.eu
OPERATING INSTRUCTION
2/11 BVD-405x
Figure 3 - Doorstation wall-mounting on the right from the entrance door
FD FC LINE LC GND +Е FB FA VO
FA - Line "-" to Apartment 1; FB - Line "-" to Apartment 2; FC - Line "-" to Apartment 3; FD - Line "-" to Apartment 4; VO - video out (for BVD-405CP-x); LINE - intercom line; LC - lock control GND - ground +Е - supply voltage for doorstation;
Figure 4 - Terminals layout and marking
3/11 www.vizit.eu
OPERATING INSTRUCTION
BVD-405x
150 cm
50 cm
Locate the doorstation so as to avoid: - direct rays of the sun or other sources of light; - direct hit of rain or snow.
50 cm
34°
50 cm
50 cm
34°
80 cm
80 cm
Figure 5 - Recommended doorstation position and camera field of view Wiring diagrams for doorphone / video doorphone are shown in the section ‘EXAMPLES OF WIRING DIAGRAMS’. Use copper wires for connections in accordance with the recommended lengths and cross-sections given in the section ‘EXAMPLES OF WIRING DIAGRAMS’. To reduce possibility of external noises influencing image, use 75-Ohm coaxial cable for video circuits. NOTE The doorstation is supplied wit a blank nameplate. The nameplate is a two-layer plastic plate with black base and silver top layer. It is intended to have inscriptions on it, such as dwellers’ names, apartment or office numbers, company names etc. Inscriptions are made by laser engraving, with removing silver layer and revealing the black base. Please refer to a specialist to have the inscriptions made. Pattern and dimensions for laser engraving are shown on Figure 6. 30.5
27
50.5
13.5 13.5
50.5
13.5
30.5
Figure 6 - Pattern and dimensions for laser engraving on the nameplate The nameplate is fixed in the niche in the doorstation’s front panel. To ensure proper fixing, clean the surface of the niche with alcohol, then remove the protective film from the adhesive tape on the nameplate’s back, and firmly attach the nameplate in the niche. 4/11 www.vizit.eu
OPERATING INSTRUCTION
BVD-405x
EXAMPLES OF WIRING DIAGRAMS
Power Supply BPD18/12-1-1
+E GND
+18 -18 -12 +12
BPD18/12-1-1 BVD-405А-2 BVD-405А-2 UKP BPD18/12-1-1 Lock
50V 1A
Doorstation BVD-405A-2 FD FC LINE LC GND +E FB FA VO
Circuit length, m 50 25
Circuits
ELECTROMECHANICAL LOCK (12 V, 1А MAX.)
Apt. 1
Apt. 2
UKP
UKP
-
-
0.25
0.5
0.5 1.0 Min. wire crosssection, mm2
LN GND +E
LN
FA
+
+
FB FA
LN
FB
Figure 7 - 2-apartment doorphone
Power Supply BPD18/12-1-1
+E GND
+18 -18 -12 +12
ELECTROMECHANICAL LOCK (12 V, 1А MAX.) 50V 1A
Doorstation BVD-405A-4
Apt. 2
Apt. 3
UKP
UKP
UKP
Apt. 4 UKP
-
-
-
-
FD FC LN GND +E
LN
FB
LN
FC
+
FA
+
LN
+
FB FA
+
FD FC LINE LC GND +E FB FA VO
Apt. 1
LN
FD
Figure 8 - 4-apartment doorphone
5/11 www.vizit.eu
OPERATING INSTRUCTION
BVD-405x
Control Unit KТМ602М
Electromagnetic lock VIZIT-ML400 -DL
Red Black Blue White
+E GND BIP RD
+DL
+E BIP RD GND LC
-DL +DL ELC BIP RD GND OP
Apt. 1
Apt. 2
Apt. 3
Apt. 4
UKP
UKP
UKP
UKP
-
-
-
-
Button EXIT 300М
GND LC
Reader RD-3
Doorstation BVD-405A-4
LC GND
+E
LC GND
+E
FD FC LN
LC GND +E
LN
Circuits KTM602M BVD-405А-4 BVD-405А-4 UKP KTM602M VIZIT-ML400
FB
LN
FC
+
FA
+
LN
+
FB FA
+
FD FC LINE LC GND +E FB FA VO
-DL +DL
Green Blue White Black Red
LN
FD
Circuit length, m 50 25
0.25
0.5
Min. wire crosssection, mm2
Figure 9 - 4-apartment doorphone with RF controller VIZIT-KTM602R
6/11 www.vizit.eu
OPERATING INSTRUCTION
BVD-405x
+12 VI VG P GND
* - video monitors that may be used in this diagram: VIZIT-M430C, VIZIT-M440C, VIZIT-M440CM, VIZIT-M456C, VIZIT-M456CM.
VGM VO +E Ec GND
Distribution Amplifier RVS-2 XP1 VI VG P GND
Jumper XP1 has to be left in place only in top RVS-2 on this diagram.
VGM VI +E Ec GND
Ec +E VI VGM GND
Ec1 +E VI1 GND LNLN+
FD LN
Monitor VIZIT*
Apt. 4 VGM VO +E Ec GND
Ec +E VI VGM GND
VGM VI +E Ec GND
Ec1 +E VI1 GND LNLN+
FC LN
Monitor VIZIT*
Power Supply BPD18/12-1-1
+E GND
+18 -18 -12 +12
+12 VI VG P GND
Apt. 3 VGM VO +E Ec GND
Distribution Amplifier RVS-2 XP1 VI VG P GND
ELECTROMECHANICAL LOCK (12 V, 1А MAX.)
BVD-405A-4 FD FC LINE LC GND +E FB FA VO
VGM VO +E Ec GND
FB FA
+12 -12 -24 +24
GND +E VG
FB LN
Monitor VIZIT*
Ec +E VI VGM GND
VGM VI +E Ec GND
Ec1 +E VI1 GND LNLN+
FA LN
Monitor VIZIT*
Apt. 1
Power Supply BPD24/12-1-1
FD FC LN
Ec1 +E VI1 GND LNLN+
Apt. 2
VI VG P GND
50V 1A
VGM VI +E Ec GND
Ec +E VI VGM GND
-12
+12 -12 GND P
+12
VI VG
Black Red Yellow Black
Outdoor Camera AP-143G Circuits BPD24/12-1-1 RVS-2 Monitors BPD18/12-1-1 BVD-405A-4 BPD24/12-1-1 AP-143G AP-143G RVS-2 Monitors BVD-405A-4 Monitors BPD18/12-1-1 Lock
Circuit length, m 25 0.5
50 1.0
0.25
0.5
0.5 1.0 Min. wire crosssection, mm 2
Figure 10 - 4-apartment video doorphone with outdoor camera and video monitors VIZIT* powered from group power supply unit
7/11 www.vizit.eu
OPERATING INSTRUCTION
BVD-405x
+12 VI VG P GND
* - video monitors that may be used in this diagram: VIZIT-M430C, VIZIT-M440C, VIZIT-M440CM, VIZIT-M456C, VIZIT-M456CM.
VGM VO +E Ec GND
Distribution Amplifier RVS-2
Jumper XP1 has to be left in place only in top RVS-2 on this diagram
VI VG P GND +12 VI VG P GND
Power Supply BPD18/12-1-1
XP1
+E GND
+18 -18 -12 +12
VGM VO +E Ec GND
VGM VO +E Ec GND
Distribution Amplifier RVS-2
ELECTROMECHANICAL LOCK (12 V, 1А MAX.)
VI VG P GND
XP1
Apt. 4 Ec1 +E VI1 GND LNLN+
FD LN
Ec +E VI VGM GND
VGM VI +E Ec GND
VGM VI +E Ec GND
Ec +E VI VGM GND
Ec1 +E VI1 GND LNLN+
Ec +E VI VGM GND
Monitor VIZIT*
Apt. 2 Ec1 +E VI1 GND LNLN+
FB LN
VGM VI +E Ec GND
Monitor VIZIT*
Apt. 3
FC LN
Monitor VIZIT*
Apt. 1
FA LN
VI VG P GND
50V 1A
VGM VO +E Ec GND
VGM VI +E Ec GND
Ec +E VI VGM GND
Ec1 +E VI1 GND LNLN+
Monitor VIZIT*
BVD-405CP-4 FD FC LINE LC GND +E FB FA VO
FD FC LN
Power Supply BPD18/12-1-1 GND +E
FB FA
VG VI
+18 -18 -12 +12
P GND
Circuit length, m 50 25 0.5 1.0
Circuits BPD18/12-1-1 BPD18/12-1-1 BVD-405CP-4 BVD-405CP-4 BPD18/12-1-1
RVS-2 Monitors BVD-405CP-4 RVS-2 Monitors Monitors Lock
0.25
0.5
0.5 1.0 Min. wire crosssection, mm 2
Figure 11 - 4-apartment video doorphone with video monitors VIZIT* powered from group power supply unit
8/11 www.vizit.eu
OPERATING INSTRUCTION
BVD-405x
* - video monitors that may be used in this diagram: VIZIT-M430C, VIZIT-M440C, VIZIT-M440CM, VIZIT-M456C, VIZIT-M456CM.
Apt. 2 Ec +E VI VGM GND
Jumper XP1 in RVS-2 has to be set in place
+12 VI VG P GND
P GND
Power Supply BPD18/12-1-1
+E GND
+18 -18 -12 +12
VGM VO +E Ec GND
Distribution Amplifier RVS-2 VI VG P GND
XP1
ELECTROMECHANICAL LOCK (12 V, 1А MAX.)
FB LN
VGM VI +E Ec GND
VGM VI +E Ec GND
VI VG P GND
50V 1A
VGM VO +E Ec GND
Ec1 +E VI1 GND LNLN+
Monitor VIZIT*
Apt. 1 Ec +E VI VGM GND
Ec1 +E VI1 GND LNLN+
FA LN
Monitor VIZIT*
BVD-405CP-2 FD FC LINE LC GND +E FB FA VO
LN GND +E
VG
FB FA
VI
Circuits BPD18/12-1-1 BPD18/12-1-1 BVD-405CP-2 BVD-405CP-2 BPD18/12-1-1
Monitors BVD-405CP-2 RVS-2 Monitors Monitors Lock
Circuit length, m 25 50 0.5 1.0
0.25
0.5
0.5 1.0 Min. wire crosssection, mm2
Figure 12 - 2-apartment video doorphone
9/11 www.vizit.eu
OPERATING INSTRUCTION
BVD-405x
* - video monitors that may be used in this diagram: VIZIT-M430C, VIZIT-M440C, VIZIT-M440CM, VIZIT-M456C, VIZIT-M456CM.
Apt. 4 V1 VG
+E VI1 GND LNLN+
FD LN
Monitor VIZIT*
GND +E
-18
+E GND
+18 -18 -12 +12
VG VI VG VO
Distribution Amplifier RVS-4
Power Supply BPD18/12-1-1
V2 VG
-18 +18
VI VG
+18 -18
Power Supply Unit 19w/14.4v/EU(18V/1.0A) 18V, 1А
+18
V1 VG V2
50V 1A
FC LN
To monitor VIZIT*
FB LN
To monitor VIZIT*
V3 VG V3 VG V4
Apt. 1
-18 +18
ELECTROMECHANICAL LOCK (12 V, 1А MAX.)
V1 VG V2 +18 -18 -18 +18 V3 VG V4
V4 VG
+E VI1 GND LNLN+
FA LN
82 Оhm
Monitor VIZIT*
BVD-405CP-4 FD FC LINE LC GND +E FB FA VO
FD FC LN
FB FA
GND +E
GND +E VG
Power Supply Unit 19w/14.4v/EU(18V/1.0A) 18V, 1А
VI
Circuits BPD18/12-1-1 BPD18/12-1-1 BVD-405CP-4 BVD-405CP-4 BPD18/12-1-1
BVD-405CP-4 RVS-4 RVS-4 Monitors Monitors Lock
Circuit length, m 25 50 0.25
0.5
0.5 1.0 Min. wire crosssection, mm 2
Figure 13 - 4-apartment video doorphone with monitors VIZIT* powered from individual power supply units
10/11 www.vizit.eu
OPERATING INSTRUCTION
BVD-405x
FUNCTIONAL CHECK AND OPERATING ORDER Before switching the power on, verify all electric connections. • Turn the power supply unit(s) on. • To make a call to the subscriber, press one of the CALL buttons on the doorstation. A call sound rings both in the corresponding monitor (apartment handset) and doorstation, while the CALL button remains pressed. Image appears on the monitor’s screen. Pick up the handset and check duplex intercom. Check image on the monitor’s screen. Adjust image brightness, contrast and saturation, if needed. Press the on the monitor (apartment handset) to release the door lock. The doorstation produces a beep, and the lock stays released while the button remains pressed. Release the button to return to the intercom mode. Hang up the handset. The system goes to the stand-by mode. Note. When called, the subscriber can press the button to release the door lock without picking up the handset. The system goes to the stand-by mode after the button is released. Intercom is available within (60 ± 5) seconds after picking up the handset. If the handset is not picked up in 60 seconds, the system returns to the stand-by mode automatically. • One by one check the rest of connected apartment handsets / monitors for intercom, video (for monitors), remote door unlocking function. SPECIFICATIONS Operating voltage: Power consumption: Dimensions (W)x(H)x(D): Weight: Weight with package:
16...25 VDC 3 W max. 60 x 160 x 43 mm 0.3 kg 0.4 kg
The built-in camera parameters (BVD-405CP-x) are given below:
Camera Parameters
Lens Angle of view (diagonal) Scanning system Colour system Resolution Minimal illumination Day-Night feature Output voltage
Pinhole 90° СCIR PAL 380 TVL 0 Lux (IR LED on 0.5 m range) 0.5 Lux (IR LED off) YES 1 Vp-p at 75 Оhm OPERATING CONDITIONS
Ambient temperature range: - BVD-405А-2(4) - 40°C to + 45°C - BVD-405CP-2(4) - 30°C to + 45°C Relative humidity of air: up to 98% at 25°C
11/11 www.vizit.eu
OPERATING INSTRUCTION
BVD-405x