Preview only show first 10 pages with watermark. For full document please download

40 с - Vizit.eu

   EMBED


Share

Transcript

BVD-405x OPERATING INSTRUCTION Doorstation BVD-405х is intended for operation in VIZIT doorphones / video doorphones (Series Comfort). The following models are available: - BVD-405А-2 - doorstation to connect 2 apartment handsets UKP; - BVD-405А-4 - doorstation to connect 4 apartment handsets UKP; - BVD-405СP-2 - video doorstation with colour camera to connect 2 video monitors; - BVD-405СP-4 - video doorstation with colour camera to connect 4 video monitors. Abbreviations used in the model names: A - No camera; С - Colour camera; P - Pinhole lens. BVD-405CP-4, BVD-405А-4 BVD-405CP-2, BVD-405А-2 1 Colour camera (BVD-405CP-2(4)) 2 IR LEDs (illumination for camera in BVD-405CP-2(4)) 1 3 Niche for nameplate 2 3 4 Speaker 5 CALL button for Apartment 4 9 6 CALL button for Apartment 3 7 CALL button for Apartment 2 4 8 7 6 5 8 CALL button for Apartment 1 9 Microphone Figure 1 - Doorstation BVD-405x FEATURES Individual CALL button for subscribers Beep in the doorstation and monitor / apartment handsets when the CALL button is pressed. Duplex intercom Door zone video monitoring (BVD-405CP-2 and BVD-405CP-4) Remote door unlocking by pressing the button on the monitor / apartment handset during intercom Beeps to indicate door lock release IR illumination for the camera (BVD-405CP-2 and BVD-405CP-4) Lighting for the nameplate Subscriber devices are VIZIT® trademarked products: - apartment handsets UKP; - video monitors VIZIT-М of Series 400. SAFETY INSTRUCTIONS The product does not contain voltage above 25 V. Do not make any connections or repair when the power is on. Take care not to spill any liquids or chemically active substances on the product. Switch the power off before cleaning the product. Clean by wiping with dry soft cloth. Do not use any liquid cleaners, aerosol cleaners or abrasive agents. 1/11 www.vizit.eu OPERATING INSTRUCTION BVD-405x PARTS LIST x1 x1 Doorstation BVD-405х Skew Base x1 x1 Blank nameplate Operating Instruction Fasteners for doorstation BVD-405х and skew base x2 x4 Gag Screw М4х16 x2 x2 Screw - 4х40 Anchor INSTALLATION ORDER The doorstation is mounted on a wall near your entrance door. The skew base provides 20° turn and allows either leftside or right-side mounting. To protect the doorstation against sun, rain or snow, installation of specially designed Mounting Kit MK-405 is recommended. Installation order of the doorstation together with its sun/rain shield is described in the Mounting Kit MK-405 installation manual. 2 3 5 4 6 7 1 1 Doorstation 4 Hole (х2) 2 Skew base 6 mm in diameter 40 mm deep 5 Anchor (х2) 6 Screw - 4х40 (х2) 7 Gag (х2) 3 Screw М4х16 (х2) Fasteners are supplied. Figure 2 - Doorstation wall-mounting on the left from the entrance door www.vizit.eu OPERATING INSTRUCTION 2/11 BVD-405x Figure 3 - Doorstation wall-mounting on the right from the entrance door FD FC LINE LC GND +Е FB FA VO FA - Line "-" to Apartment 1; FB - Line "-" to Apartment 2; FC - Line "-" to Apartment 3; FD - Line "-" to Apartment 4; VO - video out (for BVD-405CP-x); LINE - intercom line; LC - lock control GND - ground +Е - supply voltage for doorstation; Figure 4 - Terminals layout and marking 3/11 www.vizit.eu OPERATING INSTRUCTION BVD-405x 150 cm 50 cm Locate the doorstation so as to avoid: - direct rays of the sun or other sources of light; - direct hit of rain or snow. 50 cm 34° 50 cm 50 cm 34° 80 cm 80 cm Figure 5 - Recommended doorstation position and camera field of view Wiring diagrams for doorphone / video doorphone are shown in the section ‘EXAMPLES OF WIRING DIAGRAMS’. Use copper wires for connections in accordance with the recommended lengths and cross-sections given in the section ‘EXAMPLES OF WIRING DIAGRAMS’. To reduce possibility of external noises influencing image, use 75-Ohm coaxial cable for video circuits. NOTE The doorstation is supplied wit a blank nameplate. The nameplate is a two-layer plastic plate with black base and silver top layer. It is intended to have inscriptions on it, such as dwellers’ names, apartment or office numbers, company names etc. Inscriptions are made by laser engraving, with removing silver layer and revealing the black base. Please refer to a specialist to have the inscriptions made. Pattern and dimensions for laser engraving are shown on Figure 6. 30.5 27 50.5 13.5 13.5 50.5 13.5 30.5 Figure 6 - Pattern and dimensions for laser engraving on the nameplate The nameplate is fixed in the niche in the doorstation’s front panel. To ensure proper fixing, clean the surface of the niche with alcohol, then remove the protective film from the adhesive tape on the nameplate’s back, and firmly attach the nameplate in the niche. 4/11 www.vizit.eu OPERATING INSTRUCTION BVD-405x EXAMPLES OF WIRING DIAGRAMS Power Supply BPD18/12-1-1 +E GND +18 -18 -12 +12 BPD18/12-1-1 BVD-405А-2 BVD-405А-2 UKP BPD18/12-1-1 Lock 50V 1A Doorstation BVD-405A-2 FD FC LINE LC GND +E FB FA VO Circuit length, m 50 25 Circuits ELECTROMECHANICAL LOCK (12 V, 1А MAX.) Apt. 1 Apt. 2 UKP UKP - - 0.25 0.5 0.5 1.0 Min. wire crosssection, mm2 LN GND +E LN FA + + FB FA LN FB Figure 7 - 2-apartment doorphone Power Supply BPD18/12-1-1 +E GND +18 -18 -12 +12 ELECTROMECHANICAL LOCK (12 V, 1А MAX.) 50V 1A Doorstation BVD-405A-4 Apt. 2 Apt. 3 UKP UKP UKP Apt. 4 UKP - - - - FD FC LN GND +E LN FB LN FC + FA + LN + FB FA + FD FC LINE LC GND +E FB FA VO Apt. 1 LN FD Figure 8 - 4-apartment doorphone 5/11 www.vizit.eu OPERATING INSTRUCTION BVD-405x Control Unit KТМ602М Electromagnetic lock VIZIT-ML400 -DL Red Black Blue White +E GND BIP RD +DL +E BIP RD GND LC -DL +DL ELC BIP RD GND OP Apt. 1 Apt. 2 Apt. 3 Apt. 4 UKP UKP UKP UKP - - - - Button EXIT 300М GND LC Reader RD-3 Doorstation BVD-405A-4 LC GND +E LC GND +E FD FC LN LC GND +E LN Circuits KTM602M BVD-405А-4 BVD-405А-4 UKP KTM602M VIZIT-ML400 FB LN FC + FA + LN + FB FA + FD FC LINE LC GND +E FB FA VO -DL +DL Green Blue White Black Red LN FD Circuit length, m 50 25 0.25 0.5 Min. wire crosssection, mm2 Figure 9 - 4-apartment doorphone with RF controller VIZIT-KTM602R 6/11 www.vizit.eu OPERATING INSTRUCTION BVD-405x +12 VI VG P GND * - video monitors that may be used in this diagram: VIZIT-M430C, VIZIT-M440C, VIZIT-M440CM, VIZIT-M456C, VIZIT-M456CM. VGM VO +E Ec GND Distribution Amplifier RVS-2 XP1 VI VG P GND Jumper XP1 has to be left in place only in top RVS-2 on this diagram. VGM VI +E Ec GND Ec +E VI VGM GND Ec1 +E VI1 GND LNLN+ FD LN Monitor VIZIT* Apt. 4 VGM VO +E Ec GND Ec +E VI VGM GND VGM VI +E Ec GND Ec1 +E VI1 GND LNLN+ FC LN Monitor VIZIT* Power Supply BPD18/12-1-1 +E GND +18 -18 -12 +12 +12 VI VG P GND Apt. 3 VGM VO +E Ec GND Distribution Amplifier RVS-2 XP1 VI VG P GND ELECTROMECHANICAL LOCK (12 V, 1А MAX.) BVD-405A-4 FD FC LINE LC GND +E FB FA VO VGM VO +E Ec GND FB FA +12 -12 -24 +24 GND +E VG FB LN Monitor VIZIT* Ec +E VI VGM GND VGM VI +E Ec GND Ec1 +E VI1 GND LNLN+ FA LN Monitor VIZIT* Apt. 1 Power Supply BPD24/12-1-1 FD FC LN Ec1 +E VI1 GND LNLN+ Apt. 2 VI VG P GND 50V 1A VGM VI +E Ec GND Ec +E VI VGM GND -12 +12 -12 GND P +12 VI VG Black Red Yellow Black Outdoor Camera AP-143G Circuits BPD24/12-1-1 RVS-2 Monitors BPD18/12-1-1 BVD-405A-4 BPD24/12-1-1 AP-143G AP-143G RVS-2 Monitors BVD-405A-4 Monitors BPD18/12-1-1 Lock Circuit length, m 25 0.5 50 1.0 0.25 0.5 0.5 1.0 Min. wire crosssection, mm 2 Figure 10 - 4-apartment video doorphone with outdoor camera and video monitors VIZIT* powered from group power supply unit 7/11 www.vizit.eu OPERATING INSTRUCTION BVD-405x +12 VI VG P GND * - video monitors that may be used in this diagram: VIZIT-M430C, VIZIT-M440C, VIZIT-M440CM, VIZIT-M456C, VIZIT-M456CM. VGM VO +E Ec GND Distribution Amplifier RVS-2 Jumper XP1 has to be left in place only in top RVS-2 on this diagram VI VG P GND +12 VI VG P GND Power Supply BPD18/12-1-1 XP1 +E GND +18 -18 -12 +12 VGM VO +E Ec GND VGM VO +E Ec GND Distribution Amplifier RVS-2 ELECTROMECHANICAL LOCK (12 V, 1А MAX.) VI VG P GND XP1 Apt. 4 Ec1 +E VI1 GND LNLN+ FD LN Ec +E VI VGM GND VGM VI +E Ec GND VGM VI +E Ec GND Ec +E VI VGM GND Ec1 +E VI1 GND LNLN+ Ec +E VI VGM GND Monitor VIZIT* Apt. 2 Ec1 +E VI1 GND LNLN+ FB LN VGM VI +E Ec GND Monitor VIZIT* Apt. 3 FC LN Monitor VIZIT* Apt. 1 FA LN VI VG P GND 50V 1A VGM VO +E Ec GND VGM VI +E Ec GND Ec +E VI VGM GND Ec1 +E VI1 GND LNLN+ Monitor VIZIT* BVD-405CP-4 FD FC LINE LC GND +E FB FA VO FD FC LN Power Supply BPD18/12-1-1 GND +E FB FA VG VI +18 -18 -12 +12 P GND Circuit length, m 50 25 0.5 1.0 Circuits BPD18/12-1-1 BPD18/12-1-1 BVD-405CP-4 BVD-405CP-4 BPD18/12-1-1 RVS-2 Monitors BVD-405CP-4 RVS-2 Monitors Monitors Lock 0.25 0.5 0.5 1.0 Min. wire crosssection, mm 2 Figure 11 - 4-apartment video doorphone with video monitors VIZIT* powered from group power supply unit 8/11 www.vizit.eu OPERATING INSTRUCTION BVD-405x * - video monitors that may be used in this diagram: VIZIT-M430C, VIZIT-M440C, VIZIT-M440CM, VIZIT-M456C, VIZIT-M456CM. Apt. 2 Ec +E VI VGM GND Jumper XP1 in RVS-2 has to be set in place +12 VI VG P GND P GND Power Supply BPD18/12-1-1 +E GND +18 -18 -12 +12 VGM VO +E Ec GND Distribution Amplifier RVS-2 VI VG P GND XP1 ELECTROMECHANICAL LOCK (12 V, 1А MAX.) FB LN VGM VI +E Ec GND VGM VI +E Ec GND VI VG P GND 50V 1A VGM VO +E Ec GND Ec1 +E VI1 GND LNLN+ Monitor VIZIT* Apt. 1 Ec +E VI VGM GND Ec1 +E VI1 GND LNLN+ FA LN Monitor VIZIT* BVD-405CP-2 FD FC LINE LC GND +E FB FA VO LN GND +E VG FB FA VI Circuits BPD18/12-1-1 BPD18/12-1-1 BVD-405CP-2 BVD-405CP-2 BPD18/12-1-1 Monitors BVD-405CP-2 RVS-2 Monitors Monitors Lock Circuit length, m 25 50 0.5 1.0 0.25 0.5 0.5 1.0 Min. wire crosssection, mm2 Figure 12 - 2-apartment video doorphone 9/11 www.vizit.eu OPERATING INSTRUCTION BVD-405x * - video monitors that may be used in this diagram: VIZIT-M430C, VIZIT-M440C, VIZIT-M440CM, VIZIT-M456C, VIZIT-M456CM. Apt. 4 V1 VG +E VI1 GND LNLN+ FD LN Monitor VIZIT* GND +E -18 +E GND +18 -18 -12 +12 VG VI VG VO Distribution Amplifier RVS-4 Power Supply BPD18/12-1-1 V2 VG -18 +18 VI VG +18 -18 Power Supply Unit 19w/14.4v/EU(18V/1.0A) 18V, 1А +18 V1 VG V2 50V 1A FC LN To monitor VIZIT* FB LN To monitor VIZIT* V3 VG V3 VG V4 Apt. 1 -18 +18 ELECTROMECHANICAL LOCK (12 V, 1А MAX.) V1 VG V2 +18 -18 -18 +18 V3 VG V4 V4 VG +E VI1 GND LNLN+ FA LN 82 Оhm Monitor VIZIT* BVD-405CP-4 FD FC LINE LC GND +E FB FA VO FD FC LN FB FA GND +E GND +E VG Power Supply Unit 19w/14.4v/EU(18V/1.0A) 18V, 1А VI Circuits BPD18/12-1-1 BPD18/12-1-1 BVD-405CP-4 BVD-405CP-4 BPD18/12-1-1 BVD-405CP-4 RVS-4 RVS-4 Monitors Monitors Lock Circuit length, m 25 50 0.25 0.5 0.5 1.0 Min. wire crosssection, mm 2 Figure 13 - 4-apartment video doorphone with monitors VIZIT* powered from individual power supply units 10/11 www.vizit.eu OPERATING INSTRUCTION BVD-405x FUNCTIONAL CHECK AND OPERATING ORDER Before switching the power on, verify all electric connections. • Turn the power supply unit(s) on. • To make a call to the subscriber, press one of the CALL buttons on the doorstation. A call sound rings both in the corresponding monitor (apartment handset) and doorstation, while the CALL button remains pressed. Image appears on the monitor’s screen. Pick up the handset and check duplex intercom. Check image on the monitor’s screen. Adjust image brightness, contrast and saturation, if needed. Press the on the monitor (apartment handset) to release the door lock. The doorstation produces a beep, and the lock stays released while the button remains pressed. Release the button to return to the intercom mode. Hang up the handset. The system goes to the stand-by mode. Note. When called, the subscriber can press the button to release the door lock without picking up the handset. The system goes to the stand-by mode after the button is released. Intercom is available within (60 ± 5) seconds after picking up the handset. If the handset is not picked up in 60 seconds, the system returns to the stand-by mode automatically. • One by one check the rest of connected apartment handsets / monitors for intercom, video (for monitors), remote door unlocking function. SPECIFICATIONS Operating voltage: Power consumption: Dimensions (W)x(H)x(D): Weight: Weight with package: 16...25 VDC 3 W max. 60 x 160 x 43 mm 0.3 kg 0.4 kg The built-in camera parameters (BVD-405CP-x) are given below: Camera Parameters Lens Angle of view (diagonal) Scanning system Colour system Resolution Minimal illumination Day-Night feature Output voltage Pinhole 90° СCIR PAL 380 TVL 0 Lux (IR LED on 0.5 m range) 0.5 Lux (IR LED off) YES 1 Vp-p at 75 Оhm OPERATING CONDITIONS Ambient temperature range: - BVD-405А-2(4) - 40°C to + 45°C - BVD-405CP-2(4) - 30°C to + 45°C Relative humidity of air: up to 98% at 25°C 11/11 www.vizit.eu OPERATING INSTRUCTION BVD-405x