Preview only show first 10 pages with watermark. For full document please download

400 Dveu 01 Digital Power Amplifier 4 X 100w

   EMBED


Share

Transcript

400 DVEU 01 Digital Power Amplifier 4 x 100W Features and Functions  4 x 100 W rated output power  Advantages by the digital power stage: - Especially high efficiency - Low power consumption - High power density  Temperature-controlled fan  Integrated amplifier monitoring functions: - Functioning - Short-circuit - Excess temperature - Voltage failure The 400 DVEU 01 digital power amplifier is an essential part of the INDUSTRONIC communication and public address system for the US-market. An external digital interface is the link to INTRON-D intercom and public address system. It consists of four independent amplifier units. The transformer unit 400 DVTU 01 converts the amplifier output to 70V or 100V speaker line. The amplifier stands for its integrated monitoring functions and its special design for use in warning and alarm systems according to the standard DIN EN60849 / IEC60849:1998 "Sound Systems for Emergency Purposes". Other Features Components  Wide input range power supply with active PFC  Matching transformer for 70V and 100V  Usable as emergency or back-up amplifier  VU meter  Separate volume control for each channel  Rugged sheet steel case  Solid power supply  4 digital power stages  Transformer unit 400 DVTU 01 with four 70/100V transformer Doc. No. DAT-304-200-100 • Rev. 2 • US• 15.02.2013 © INDUSTRONIC Subject to technical modifications 1/3 Figure 1: Block diagram 400 DVEU 01 and 400 DVTU 01 Mechanical Data Amplifier Transformer  Design 19 inch slide in chassis / 1RU (483 mm / 44 mm)  Width x Height x Depth 483 mm x 44 mm x 210 mm (19 x 1¾ x 8¼ inch)  Weight 2.3kg 5.07 Ibs  Width x Height x Depth 483 mm x 44 mm x 229 mm (19 * 1¾ * 9 inch)  Weight 8.2 kg 18.08 lbs Doc. No. DAT-304-200-100 • Rev. 2 • US• 15.02.2013 © INDUSTRONIC Subject to technical modifications 2/3 Electrical Data Power consumption  Output power 4 x 100 W  Output voltage transformer 70 / 100 V  Operating voltage range 95 to 265 VAC @ 50 / 60 Hz  Efficiency >70%  Distortion < 0.1%  Signal to noise ratio > 90 dB  Frequency response 40 to 20,000 Hz +/- 1.5 dB  AF input voltage 1.23 to 9.76 V  Internal fuse 5 A time lag  Temperature range 23°F to 113°F (-5°C to 45°C)  Safety standards and Listings CE, CULUS  Quiescent 41 VA  Nominal power 500 VA ® INDUSTRONIC Inc. 1011 US Highway 22 West Suite 301 Bridgewater, NJ 08876, USA Tel. +1 9083935960 Fax: +1 9083935961 [email protected] www.industronic.com Doc. No. DAT-304-200-100 • Rev. 2 • US• 15.02.2013 © INDUSTRONIC Subject to technical modifications 3/3