Preview only show first 10 pages with watermark. For full document please download

402-1008 - Te Connectivity

   EMBED


Share

Transcript

402-1008 April 22nd, 2014 Rev D3 MPO Cable Assembly Configure to Order Model Scope: This specification defines the cable assemblies that can be created by the MP catalog configuration scheme for the creation of 12 fiber ferrule based MPO cable assemblies from 12 to 144 fibers total. All assemblies are designed to the requirements of TIA 568-C.3. Figure 1: 12 fiber MPO to MPO assembly on 3mm interconnect cable. Figure 2: MPO to MPO assembly on 24 fiber 3mm interconnect zipcord cable (12 fibers per leg). Figure 3: 12 fiber MPO to MPO assembly on 12 fiber backbone cable with 1x12 fiber 3mm interconnect subunit. Figure 4: MPO to LC, SC, ST, FC, or MT-RJ. Fiber counts from 12 to 144 fibers. Packaging: All assemblies will come with protective covers over the MPO connectors. Assemblies made with backbone cable will come with a pulling sock over the left side MPO connector(s) and a protective cover over the right side connectors. The pulling sock will cover the entire breakout area up to the larger diameter backbone cable. The pulling sock diameter for assemblies with up to 6 MPO connectors is 1.125 inch (28.5mm), 8 or 12 MPO assembly pulling socks increase to 1.25 inch (38mm). 12 fiber interconnect assemblies up to 30 meters in length will come in a bag. 24 fiber interconnect zipcord assemblies up to 10 meters in length will come in a bag. All other assemblies will come on a reel. © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. TE Connectivity, and TE connectivity (logo) are trademarks. Other logos, product and/or company names might be trademarks of their respective owners. This specification is subject to change without notice. 1 of 16 402-1008 M P X - 1 X X X X X X X 2 3 4 5 6 7 8 Position 1: Performance/Polarity X X 9-11 Position 4: Side B Connector (continued) A Polarity A (Straight Through) with Standard Performance T Polarity A (Straight Through) with Optimate Performance S B Polarity B (Reversed) with Standard Performance F X X - 12 X X 13-14 Position 7: Fiber Type 1 62.5/125µm OM1 SC Duplex 2 50/125µm OM2 T ST Duplex 3 OM3 Polarity B (Reversed) with Optimate Performance F FC 4 OM4 C Polarity C (Pairs Flipped) with Standard Performance M MTRJ Plug without pins 5 OS2 E Polarity C (Pairs Flipped) with Optimate Performance W MTRJ Plug with pins 6 SC APC Duplex (Single-mode only) Position 2: Side A Connector Type N 12 Fiber MPO without Pins P 12 Fiber MPO with Pins C 12 Fiber MPO Secure without Pins E 12 Fiber MPO Secure with Pins Position 3: Side A Color/Keying C Standard Connector B Blue N Orange G Green W Brown S Slate R Red Y Yellow V Violet P Rose A Aqua 7 LC APC Duplex (Single-mode only) 8 LC Secure Duplex 9 MT-RJ Secure Duplex Position 5: Side B Color/Keying Position 8: Cable Jacket Color 0 Industry Standard Color (by Fiber Type) B Blue N Orange G Green W Brown C Standard Connector S Slate 0 None (Pigtail) R Red B Blue K Black N Orange Y Yellow G Green V Violet W Brown P Rose S Slate A Aqua R Red Y Yellow V Violet P Rose A Aqua Position 9-11: Assembly Length XXX Assembly Length (Must Be 3 Digits) Position 12: Unit of Measure F Feet M Meters Position 6: Cable Type Position 4: Side B Connector N 12 Fiber MPO without Pins P 12 Fiber MPO with Pins C 12 Fiber MPO Secure without Pins E 12 Fiber MPO Secure with Pins 0 None (Pigtail) L LC Duplex Table Continued Above…. REV D3 J 12 Fiber 3mm Interconnect, OFNP Z 24 Fiber 3mm Interconnect Zipcord, OFNP Position 13: Breakout Length A TFP 30.5 inches (77.5 cm) 1 12 Fiber Backbone, 1x12F, with 3mm Interconnect Subunit, OFNP B NFG 13.75 inches (34.9 cm) D 24 Fiber Backbone, 2x12F, with 3mm Interconnect Subunits, OFNP C 18 Inches 18 Inches (45.7 cm) 3 36 Fiber Backbone, 3x12F, with 3mm Interconnect Subunits, OFNP F RMG 25 Inches (63.5 cm) 4 48 Fiber Backbone, 4x12F, with 3mm Interconnect Subunits, OFNP N No Breakout or Pigtail N/A 7 72 Fiber Backbone, 6x12F, with 3mm Interconnect Subunits, OFNP S Standard 36 Inches (91.4 cm) 9 96 Fiber Backbone, 8x12F, with 3mm Interconnect Subunits, OFNP U 79 Inches 79 Inches (200.6 cm) H 144 Fiber Backbone, 12x12F, with 3mm Interconnect Subunits, OFNP XX Custom. (From 10 to 99.) XX 2 of 16 402-1008 MP X - 1 X X X X X X X XXX X 2 3 4 5 6 7 8 9-11 12 - XX 13-14 Position 1 (Table 1 of 2) Performance/Polarity for MPO to MPO See Assembly Performance tables on page 5 for assembly performance specifications. Catalog Number Description Polarity A (Straight Through) A with Standard Performance Polarity A (Straight Through) T with Optimate Performance Polarity B (Reversed) B with Standard Performance Polarity B (Reversed) F with Optimate Performance Polarity C (Pairs Flipped) C with Standard Performance Polarity C (Pairs Flipped) E REV D3 with Optimate Performance Connector A Fiber Number 1 2 3 4 5 6 7 8 9 10 11 12 Connector A Fiber Number 1 2 3 4 5 6 7 8 9 10 11 12 Connector A Fiber Number 1 2 3 4 5 6 7 8 9 10 11 12 Fiber Color BL OR GR BR SL WH RD BK YL VI RS AQ Fiber Color BL OR GR BR SL WH RD BK YL VI RS AQ Fiber Color BL OR GR BR SL WH RD BK YL VI RS AQ Connector B Fiber Number 1 2 3 4 5 6 7 8 9 10 11 12 Connector B Fiber Number 12 11 10 9 8 7 6 5 4 3 2 1 Connector B Fiber Number 2 1 4 3 6 5 8 7 10 9 12 11 3 of 16 402-1008 Position 1 (Table 2 of 2) Performance/Polarity for MPO to MT-RJ, LC, SC, ST, or FC Polarity A must be chosen when connector B is a simplex connector (FC, ST, LC/APC, or SC/APC). Optimate performance can only be chosen when connector B is MPO, LC, or SC. Catalog Number Description Connector B Connector A Fiber Number Fiber Color with Optimate Performance 1 2 3 4 5 6 7 8 9 10 11 12 BL OR GR BR SL WH RD BK YL VI RS AQ Polarity C Connector A Fiber Number Fiber Color 1 2 3 4 5 6 7 8 9 10 11 12 BL OR GR BR SL WH RD BK YL VI RS AQ Polarity A A (Straight Through) with Standard Performance Polarity A T (Straight Through) Fiber Number 1 2 3 4 5 6 7 8 9 10 11 12 Pair Duplex Position A B A B A B A B A B A B 1 2 3 4 5 6 Connector B (Pairs Flipped) C with Standard Performance Polarity C (Pairs Flipped) E with Optimate Performance REV D3 Fiber Number 2 1 4 3 6 5 8 7 10 9 12 11 Pair 1 2 3 4 5 6 Duplex Position B A B A B A B A B A B A 4 of 16 402-1008 Assembly Performance: Maximum cable assembly loss can be calculated by adding the maximum loss of the connectors on both ends and the cable between. The necessary values are in the tables below. Single-mode OS2 LC, SC, MT-RJ LC APC ST, FC 12F MPO Insertion Loss (dB Maximum) Return Loss (dB Minimum) Insertion Loss (dB Maximum) Return Loss (dB Minimum) 1310nm 1550nm 1310nm 1550nm SC APC, FC APC 0.50 0.50 0.20 0.30 0.30 0.50 55 55 0.50 26 26 0.20 65 65 0.30 65 65 0.30 65 65 LC, SC, ST, and FC Multimode LC, SC OPTIMATE MT-RJ OM1, OM2, OM3, OM4 OM3, OM4 OM1, OM2, OM3, OM4 0.35 0.15 0.50 0.35 20 20 0.15 35 35 0.50 20 20 850nm 1300nm 850nm 1300nm Multimode 12 Fiber MPO Insertion Loss (dB Maximum) Return Loss (dB Minimum) 62.5/125 OM1 50/125 OM2, OM3, OM4 OPTIMATE OM3, OM4 0.50 0.50 0.35 0.50 20 20 0.50 23 23 28 - 850nm 1300nm 850nm 1300nm Maximum Cable Attenuation 62.5/125 µm Bend Insensitive OM1 50/125 µm (850nm/1300nm) OM2 (850nm/1300nm) Cable Maximum Attenuation (These are the attenuation values for the cable only). REV D3 3.5/1.2 dB/km 3.5/1.5 dB/km Bend Insensitive Bend Insensitive OM3 OM4 (850nm/1300nm) (850nm/1300nm) 3.0/1.0 dB/km 3.0/1.0 dB/km Bend Insensitive Single-mode OS2 (1310nm/1550nm) 0.4/0.3dB/km 5 of 16 402-1008 MP X 1 - X X X X X X X XXX X 2 3 4 5 6 7 8 9-11 12 - XX 13-14 Position 2 Connector A Type TE Connectivity MPO cassettes are made with pins. Therefore cables for use with MPO cassettes should be without pins. Catalog Number Description 12 Fiber MPO without Pins N TE Connectivity MPO cassettes are made with pins. Therefore cables for use with MPO cassettes should be without pins. Example: Standard performance MPO with OM3 or OM4 fiber. P 12 Fiber MPO with Pins Example: Standard performance MPO with OM3 or OM4 fiber. Secure Connectors (Use Position 3 to Select Secure Connector Color) C 12 Fiber MPO SECURE without Pins Example: Red MPO SECURE with OM3 or OM4 fiber. E 12 Fiber MPO SECURE with Pins Example: Red MPO SECURE with OM3 or OM4 fiber. REV D3 6 of 16 402-1008 MP X - 1 X X X X X X X XXX X 2 3 4 5 6 7 8 9-11 12 - XX 13-14 Position 3 Connector A Color/Keying Housing Colors by Fiber Type/Performance Catalog Number Description Inner Housing Color/Outer Housing (Slider) Color OM1 OM2 OM3/OM4 Single-mode OPTIMATE Inner/Outer Inner/Outer Inner/Outer Inner/Outer Inner/Outer Black/Beige Black/Black Black/Aqua Black/Green Black/Mustard Standard Connector Use this value for standard connectors (connectors that are not keyed for SECURE adapters). C SECURE Connector Colors/Keying MPO SECURE plugs are designed for use with MPO SECURE cassettes and will only mate with like colored adapters. B N G W S R Y V P A REV D3 Blue Orange Green Brown Slate Red Yellow Violet Rose Aqua Blue/Beige Blue/Black Blue/Aqua Blue/Green Blue/Mustard Orange/Beige Orange/Black Orange/Aqua Orange/Green Orange/Mustard Green/Beige Green/ Black Green/Aqua Green/Green Green/Mustard Brown/Beige Brown/ Black Brown/Aqua Brown/Green Brown/Mustard Slate/Beige Slate/Black Slate/Aqua Slate/Green Slate/Mustard Red/Beige Red/Black Red/Aqua Red/Green Red/Mustard Yellow/Beige Yellow/Black Yellow/Aqua Yellow/Green Yellow/Mustard Violet/Beige Violet/Black Violet/Aqua Violet/Green Violet/Mustard Rose/Beige Rose/Black Rose/Aqua Rose/Green Rose/Mustard Aqua/Beige Aqua/Black Aqua/Aqua Aqua/Green Aqua/Mustard 7 of 16 402-1008 MP X 1 - X X X X X X X XXX X 2 3 4 5 6 7 8 9-11 12 - XX 13-14 Position 4 Connector B Type Catalog Number 0 Description None Use this value for a pigtail assembly. 12 Fiber MPO without Pins N TE Connectivity MPO cassettes are made with pins. Therefore cables for use with MPO cassettes should be without pins. P 12 Fiber MPO with Pins L LC Duplex S SC Duplex T ST F FC M MTRJ Plug without pins W MTRJ Plug with pins 6 SC APC Duplex (Single-mode only) 7 LC APC Duplex (Single-mode only) Secure Connectors (Use Position 2 to Select Secure Connector Color) 12 Fiber MPO SECURE without Pins C TE Connectivity MPO cassettes are made with pins. Therefore cables for use with MPO cassettes should be without pins. E 12 Fiber MPO SECURE with Pins 8 LC SECURE Duplex 9 MT-RJ SECURE Plug REV D3 8 of 16 402-1008 MP X - 1 X X X X X X X XXX X 2 3 4 5 6 7 8 9-11 12 - XX 13-14 Position 5 (Table 1 of 2) Connector B Color/Keying for MPO Housing Colors by Fiber Type/Performance Catalog Number Description Inner Housing Color/Outer Housing (Slider) Color OM1 OM2 OM3/OM4 Single-mode OPTIMATE Inner/Outer Inner/Outer Inner/Outer Inner/Outer Inner/Outer Black/Beige Black/Black Black/Aqua Black/Green Black/Mustard - - - - - Standard Connector Use this value for standard connectors (connectors that are not keyed for SECURE adapters). C None 0 Use this value for a pigtail assembly. Secure Connector Colors/Keying MPO SECURE plugs are designed for use with MPO SECURE cassettes and will only mate with like colored adapters. B N G W S R Y V P A REV D3 Blue Orange Green Brown Slate Red Yellow Violet Rose Aqua Blue/Beige Blue/Black Blue/Aqua Blue/Green Blue/Mustard Orange/Beige Orange/Black Orange/Aqua Orange/Green Orange/Mustard Green/Beige Green/ Black Green/Aqua Green/Green Green/Mustard Brown/Beige Brown/ Black Brown/Aqua Brown/Green Brown/Mustard Slate/Beige Slate/Black Slate/Aqua Slate/Green Slate/Mustard Red/Beige Red/Black Red/Aqua Red/Green Red/Mustard Yellow/Beige Yellow/Black Yellow/Aqua Yellow/Green Yellow/Mustard Violet/Beige Violet/Black Violet/Aqua Violet/Green Violet/Mustard Rose/Beige Rose/Black Rose/Aqua Rose/Green Rose/Mustard Aqua/Beige Aqua/Black Aqua/Aqua Aqua/Green Aqua/Mustard 9 of 16 402-1008 Position 5 (Table 2 of 2) Connector B Color/Keying for LC and MT-RJ Catalog Description Number C 0 Standard Connector Use this value for standard connectors (connectors that are not keyed for SECURE adapters). None Use this value for a pigtail assembly. Secure Connector Colors/Keying B N G W S R Y V P A REV D3 Blue Orange Green Brown Slate Red Yellow Violet Rose Aqua 10 of 16 402-1008 MP X 1 - X X X X X X X XXX X 2 3 4 5 6 7 8 9-11 12 - XX 13-14 Position 6 (Table 1 of 2) Cable Type Catalog Number Description J 12 Fiber 3mm Interconnect, OFNP Z 24 Fiber 3mm Interconnect Zipcord, OFNP 1 12 Fiber Backbone, 1x12F, with 3mm Interconnect Subunit, OFNP (Suitable for either horizontal or vertical backbone installations.) D 24 Fiber Backbone, 2x12F, with 3mm Interconnect Subunits, OFNP (Suitable for either horizontal or vertical backbone installations.) 3 36 Fiber Backbone, 3x12F, with 3mm Interconnect Subunits, OFNP 4 48 Fiber Backbone, 4x12F, with 3mm Interconnect Subunits, OFNP REV D3 11 of 16 402-1008 Position 6 (Table 2 of 2) Cable Type Catalog Number Description 7 72 Fiber Backbone, 6x12F, with 3mm Interconnect Subunits, OFNP 9 96 Fiber Backbone, 8x12F, with 3mm Interconnect Subunits, OFNP H 144 Fiber Backbone, 12x12F, with 3mm Interconnect Subunits, OFNP REV D3 12 of 16 402-1008 MP X - 1 X X X X X X X XXX X 2 3 4 5 6 7 8 9-11 12 - XX 13-14 Position 7 Fiber Type (See Fiber Characteristics Table for Detail) Catalog Number Description 1 2 3 4 5 62.5/125µm OM1 50/125µm OM2 OM3 OM4 Single-mode OS2 Fiber Characteristics: 62.5/125 µm OM1 (850nm/1300nm) Bend Insensitive 50/125 µm OM2 (850nm/1300nm) Cable Maximum Attenuation (These are the attenuation values for the cable only). OFL Bandwidth 850nm Effective Modal Bandwidth 10GBASE-SR Maximum Distance 40GBASE-SR4 Maximum Distance 100GBASESR10 Maximum Distance Fiber Specification REV D3 Bend Insensitive Bend Insensitive OM3 OM4 (850nm/1300nm) (850nm/1300nm) Bend Insensitive Single-mode OS2 (1310nm/1550nm) 3.5/1.2 dB/km 3.5/1.5 dB/km 3.0/1.0 dB/km 3.0/1.0 dB/km 0.4/0.3dB/km 200/500 MHzkm 500/500 MHzkm 1500/500 MHzkm 3500/500 MHzkm Not Applicable Not Applicable Not Applicable 2000 MHzkm 4700 MHzkm Not Applicable 33m 82m 300m 550m Not Applicable Not Applicable Not Applicable 100m 150m Not Applicable Not Applicable Not Applicable 100m 150m Not Applicable TIA-492AAAA IEC 60793-210 A1b TIA-492AAAB IEC 60793-210 A1a.1 TIA-492AAAC IEC 60793-210 A1a.2 TIA-492AAAD IEC 60793-210 A1a.3 ITU-T G.657.A2 13 of 16 402-1008 MP X - 1 X X X X X X X XXX X 2 3 4 5 6 7 8 9-11 12 - XX 13-14 Position 8 Cable Jacket Color Catalog Number Description Standard Color 0 Use this value for industry standard cable colors. Industry Standard Colors By Fiber Type Orange Orange Aqua Aqua Yellow OM1 OM2 OM3 OM4 Singlemode Custom Cable Colors B N G W S R K Y V P A REV D3 Blue Orange Green Brown Slate Red Black Yellow Violet Rose Aqua 14 of 16 402-1008 MP X - 1 X X X X X X X XXX X 2 3 4 5 6 7 8 9-11 12 - XX 13-14 Positions 9-11 Assembly Length Measured from Tip of Connector A Ferrule to Tip of Connector B Ferrule. The unit of measure is dependent on the selection in Position 12. Each pair of subunits beyond the first two will be 2 inches longer on each end of the assembly, as shown above (This allows a smaller pulling sock to be used). Catalog Number Description 001 999 Shortest possible assembly length. Longest possible assembly length. MP X 1 - X X X X X X X XXX X 2 3 4 5 6 7 8 9-11 12 - XX 13-14 Position 12 Unit of Measure REV D3 Catalog Number Description F M Feet Meters 15 of 16 402-1008 MP X 1 - X X X X X X X XXX X 2 3 4 5 6 7 8 9-11 12 - XX 13-14 Position 13-14 Breakout Length Choose the breakout length for each end. An entry of BF will result in 13.75 inches on the left and 25 inches on the right. The breakout length is defined from the end of the heat shrink transition to the tip of the connector ferrule as shown. The 7” section of exposed subunit shown here will exist on assemblies with any connector other than MPOs selected for connector B, and is non-configurable. Each pair of subunits beyond the first two will be 2 inches longer on each end of the assembly, as shown above. Catalog Number Description Length A TFP 30.50 B C F Choose this option for use with TFP cabinets. NGF Choose this option for use with NGF cabinets. 18 Inches RMG Choose this option for use with RMG cabinets. No Breakout (Inches) 13.75 18 25 N Use this choice when ordering 12 or 24 fiber interconnect assemblies (cable type J or 2), as there will be no breakout. No Breakout S U Standard 79 Inches Custom Dimension 36 79 XX REV D3 Choose a value from 10 to 99 inches. Custom length breakouts will be the same on each end of the cable assembly. XX 16 of 16