Preview only show first 10 pages with watermark. For full document please download

4096-360

   EMBED


Share

Transcript

Purple Blue Red/Yellow 59 Yellow/Red Term. Block #3 Black Red Black 50 Blue Red Red Brown Red/White 34 Red/Black Outdoor Fan Relay 54 3 1 A Red COM 230V L1 460 Transformer M2 27 Brown 28 RT L1 L2 L3 Y Yo C G W3 C E Y L Y1 DH B O1 W1 Black/White Yellow 29 Discharge Line Thermostat 11 Capacitor 38 60 32 24VAC RED 8 BLK 7 RV HOT 4 RV COM 3 Low Amb. Press. Trans. (Opt.) 24 VAC H 2 24 VAC C 1 R CC LOR-1 LI 230V/460V Transformer Yout Y Black Black 23 C Red Y Y L L Lockout Relay Control 45 High Speed Solenoid C Defrost Sensor SENSOR LOR-2 W1 B B W2 W2 RV DFC-1 DFC-2 Reversing Valve G Black W3 Yellow 22 Red Red 24 Red 19 44 230V L3 Terminal Block 12 Ground Lug 13 47 Defrost Control Low Pressure Control Black L2 C Defrost Control COM Out. Fan Relay BLU 9 Red L1 Phase Monitor L1 L2 L3 Yellow 460V 48 43 Compressor Contactor R High Pressure Control Yellow Phase Monitor Disch. Line Tstat L2 Yellow R W2 Out. Fan Relay 1 3 A Low Ambient Control (Opt.) COM Ground Red Yellow 50 HZ ONLY IF APPLICABLE C Black 40 Low Voltage Term. Block Red (Low Spd) Black Red Blue Black/White Red/White Black/White Blue 1 2 3 4 5 6 7 8 9 Black (High Spd) RT Blue N.C. HEAT PUMP 24 VAC C 24 VAC H COM RV HOT RV NC NC BLK RED BLU 20 MIN Outdoor Fan Motor (see chart) 460V Black Red Yellow Black Black/White HARD START MAX L2 Y1 21 High Speed Solenoid MAX Low Ambient Control (Opt.) T3 Outdoor Fan Motor Capacitor L3 L0 MIN CUT OUT SPD L3 Transformer 8 39 21 L3 R T1 T2 T3 A Yellow Blue M2 L2 240V 480V L1 L1 36 Yellow/Black L2 VARIABLE SPEED L3 L2 51 Compressor FULL SPEED L1 Black/White Blue Low Pressure Control Black Red 21 35 35 115 155 195 235 SET 275 POINT 315 355 465 435 395 25 Compressor Contactor Yellow 60 Blue Black/Red T2 36 41 7 Coil Sensor 49 Hi Pressure Control L2 L2 Black/White 26 Low Amb. Pressure Transducer (Opt.) L1 Compressor Brown Yellow/Black Term. Block #3 T1 A Yellow Reversing Valve 230V/460V Transformer Fuse Block Compressor Contactor Orange Pink Blue L1 L2 L3 Low Ambient Control (Opt.) C 5 Low Voltage Term. Block CC 4 Line 3 to power source or optional heater package Y 3 Line 2 to power source or optional heater package W2 L2 1 Line 1 to power source or optional heater package C 6 Red L1 2 4 Black/White L 5 Orange/Blk SENSOR R RV 3 9 Yellow Red/White Blue B 6 5 Pin Plug for Indoor Blower Motor 4 5 3 460V Brown Black/White Black/White R 14 460-60-3 Power Source B L1 Black/White NC LO 2 15 10 12 31 Heater Package Black 10 1 6 Pin Plug for Optional 5 Pin Plug 9 Red COM 3 SEN JMP NO TERM SPEED TEMP UP 30 60 90 2 1 Defrost Control Indoor Blower Motor 16 Pin Plug 30 56 55 2 6 1 4 6 Pin Plug for Heater Package C 46 Black Yellow A Fuse 57 58 Block B 3 15 10 2 B 6 9 14 12 3 1 16 Pin Plug for Indoor Blower Motor Wire Identification numbers Wires Connect 99 for Bard use only. if Option Not Used Factory Field Optional High Voltage Standard Diagram Low Voltage Ladder Diagram Jumper Installed if no heater package used. ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. Bard Mfg. Co. Bryan, Ohio 4096-360 A