Transcript
Optical Communication System
Datasheet 40GBASE-PLR4 QSFP +1310nm 10km MTP/MPO Transceiver for SMF QSFP-PLR4-40G Features •
Hot-pluggable QSFP+ form factor
•
Supports 4 independent streams of 10G Ethernet or OTN data
•
Power dissipation < 2.5W
•
RoHS-6 compliant
•
Commercial case temperature range 0°C to 70°C
•
Single 3.3V power supply
•
Maximum link length of 10km on Single Mode Fiber (SMF)
•
XLPPI electrical interface
•
MPO12 receptacle
•
Built-in digital diagnostic functions, including Tx/Rx power monitoring
Application •
10GBASE-LR/LW 10G Ethernet
•
OTU2, OTU1e, OTU2e
1
Optical Communication System
Datasheet Description QSFP+ transceiver modules are designed for use in high density 10 Gigabit Ethernet links over single mode fiber. They are compliant with the QSFP+ MSA, IEEE 802.3ae 10GBASELR/LW, and OTN data rates OTU2, OTU1e, and OTU2e per the ITU. Digital diagnostics functions are available via an I2C interface, as specified by the QSFP+ MSA. The transceiver is RoHS compliant per Directive 2011/65/EU5.
Product Specifications I. General Product Characteristics Parameter
Value
Module Form Factor
QSFP+
Maximum Aggregate Data Rate Maximum Data Rate per Lane
Unit
44.4
Gb/s
11.095
Gb/s
Notes
Protocols Supported
10G Ethernet
This module is not retimed
Electrical Interface and Pin-out
38-pin edge connector
Pin-out as defined by the QSFP+ MSA
Maximum Power Consumption Management Interface
2.5
Watts
Serial, I2C-based, 400 kHz maximum frequency
2
As defined by the QSFP+ MSA
Copyright © 2009-2015 Fiberstore Copyright © 2009-2015 Fiberstore Optical Communication System
Datasheet Data Rate Specifications
Symbol
Min
Bit Rate per Lane
BR
9.95
Bit Error Ratio
BER
10-12
d
10
Link distance on SMF-28
Typ.
Max
Units
Ref.
11.10
Mb/sec
1 2
kilometers
Notes: 1. Compliant with 10GBASE-LR/LW, OTU2, OTU1e, and OTU2e and XLPPI. 2. Tested with a PRBS 2-1 test pattern.
II. Absolute Maximum Ratings Max
Unit
-0.5
3.6
V
Ts
-40
85
°C
Case Operating Temperature
Top
0
70
°C
Relative Humidity
RH
0
85
%
Damage Threshold, per Lane
DT
3.4
Parameter Maximum Supply Voltage Storage Temperature
Symbol
Min
Vcc1, VccTx, VccRx
Typ.
Ref.
1
dBm
Note: Non-condensing.
Page 3+86 of 4(755)
[email protected] (755) 8300 3611
[email protected] 3 www.fiberstore.com 8300 3611
[email protected] [email protected] www.fiberstore.com +86 (755) 8300 3611 FSCOM
www.fiberstore.com
Optical Communication System
Datasheet III. Electrical Characteristics (TOP = 0 to 70℃, VCC = 3.1 to 3.47 Volts) Parameter
Symbol
Min
Supply Voltage
Vcc1, VccTx, VccRx
3.1
Supply Current
Icc
Typ.
Transmit turn-on time
Max
Unit
3.47
V
1.13
A
2000
ms
Ref.
2
Transmitter (per Lane) Single ended input voltage tolerance Differential data input swing
VinT
-0.3
4.0
V
Vin,pp
120
1200
mVpp
Differential input threshold
50
AC common mode input
15
voltage tolerance (RMS) Differential input return loss
mV mV
Per IEEE P802.3ba,Section 86A.4.1.1
dB
J2 Jitter Tolerance
Jt2
0.17
UI
J9 Jitter Tolerance
Jt9
0.29
UI
DDPWS
0.07
UI
Data Dependent Pulse Width Shrinkage Eye mask colordinates {X1, X2 ,Y1, Y2}
3
0.11, 0.31 95, 350
Page 4+86 of 4(755) +86
[email protected] (755) 8300 3611
[email protected] 4 www.fiberstore.com 8300 3611
[email protected] [email protected] www.fiberstore.com +86 (755) 8300 3611 FS.COM
UI mV
4
5
Page 4 of 6 www.fiberstore.com
Optical Communication System
Datasheet Receiver (per Lane) Single-ended output voltage
-0.3 200 300 400 600
Differential data outputswing Vout,pp AC common mode output voltage (RMS) Termination mismatch at 1 MHx
4.0
V
400 600 800 1200
mVpp
7.5
mV
5
%
6,7
Differential output return loss
Per IEEE P802.3ba,Section 86A.4.2.1
dB
4
Common mode output return loss
Per IEEE P802.3ba,Section 86A.4.2.2
dB
4
Output transition time, 20% to 80%
28
ps
J2 Jitter output
Jo2
0.42
UI
J9 Jitter output
Jo9
0.65
UI
Eye mask coordinates #1 {X1, X2, Y1, Y2} Power Supply Ripple Tolerance
0.29, 0.5 150, 425 PSR
50
UI mV
5
mVpp
Notes: 1. Maximum total power value is specified across the full temperature and voltage range. 2. From power-on and end of any fault conditions. 3. After internal AC coupling. Self-biasing 100Ω differential input. 4. 10 MHz to 11.1 GHz range 5. Hit ratio = 5 x 10E-5. 6. AC coupled with 100Ω differential output impedance. 7. Output voltage settable in four discrete ranges via I2C command.
5
Optical Communication System
Datasheet IV. Optical Characteristics (TOP = 0 to 70℃, VCC = 3.1 to 3.47 Volts) Parameter
Symbol
Typ.
Min
Max
Unit
Ref.
9.95
10.095
GBd
1
λ
1290
1330
TXPx
-6.0
-1.0
dBm
2
TxOMA
-5.2
3.0
dBm
3.2
dB
Transmitter Signaling Speed per Lane Lane center wavelength Average Launch Power per Lane Transmit OMA per Lane Transmitter and Dispersion Penalty
TDP
Transmit OMA per lane minus TDP Optical Extinction Ratio Sidemode Suppression ratio
-6.2
m
ER
6.0
dB
SSRmin
30
dB
Average launch power of OFF transmitter, per lane
-30
dBm
dB/Hz
Relative Intensity Noise
RIN
-128
Tx Jitter
Txj
-20
Transmitter Reflectance Transmitter eye mask definition
-12 Per 802.3ae, G.693, and G.691
6
dB
3
Optical Communication System
Datasheet Parameter
Max
Unit
Ref.
9.95
10.095
GBd
4
1260
1355
Min
Symbol
Typ.
Receiver Signaling Speed per Lane Lane center wavelength
λ
1.5
dBm
0.5
dBm
Rxsens
-12.6
dBm
SRS
-10.3
dBm
RL
-14
dBm
12.3
GHz
-14
dBm
-17
dBm
Damage Threshold per Lane
PMAX
Average Receive Power per Lane
RXPx
Receiver Sensitivity (OMA) per Lane Stressed Receiver Sensitivity (OMA) per Lane Return Loss
-14.4
Receive electrical 3 dB upper cutoff frequency, per lane LOS De-Assert
LOSD
LOS Assert
LOSA
-30
LOS Hysteresis
0.5
dB
Notes: 1. Transmitter consists of 4 lasers operating between 9.95 and 11.10 Gb/s each. 2. Minimum value is informative. 3. RIN is scaled by 10*log(10/4) to maintain SNR outside of transmitter. 4. Receiver consists of 4 photodetectors operating between 9.95 and 11.10 Gb/s each. 5. Minimum value is informative, equals min TxOMA with infinite ER and max channel insertion loss.
7
5
Optical Communication System
Datasheet V. Pin Description
Figure 1 – QSFP+ MSA-compliant 38-pin connector Pin
Symbol
Name/Description
Notes
1
GND
Ground
1
2
Tx2n
Transmitter Inverted Data Input
3
Tx2p
Transmitter Non-Inverted Data Input
4
GND
Ground
5
Tx4n
Transmitter Inverted Data Input
6
Tx4p
Transmitter Non-Inverted Data Input
7
GND
Ground
8
ModSelL
Module Select
9
ResetL
Module Reset
8
1
1
Optical Communication System
Datasheet Datasheet 10
Vcc Rx
+3.3 V Power supply receiver
11
SCL
2-wire serial interface clock
12
SDA
2-wire serial interface data
13
GND
Ground
14
Rx3p
Receiver Non-Inverted Data Output
15
Rx3n
Receiver Inverted Data Output
16
GND
Ground
17
Rx1p
18
Rx1n
Receiver Inverted Data Output
19
GND
Ground
1
20
GND
Ground
1
21
Rx2n
Receiver Inverted Data Output
22
Rx2p
Receiver Non-Inverted Data Output
23
GND
Ground
24
Rx4n
Receiver Inverted Data Output
25
Rx4p
Receiver Non-Inverted Data Output
26
GND
Ground
27
ModPrsL
Module Present
28
IntL
Interrupt
29
Vcc Tx
+3.3 V Power supply transmitter
30
Vcc1
+3.3 V Power Supply
31
LPMode
Low Power Mode
32
GND
Ground
33
Tx3p
Transmitter Non-Inverted Data Input
1
1
Receiver Non-Inverted Data Output
9
1
1
1
Optical Communication System
Datasheet
34
Tx3n
Transmitter Inverted Data Input
35
GND
Ground
36
Tx1p
Transmitter Non-Inverted Data Input
37
Tx1n
Transmitter Inverted Data Input
38
GND
Ground
1
1
Note: Circuit ground is internally isolated from chassis ground.
VI. Mechanical Specifications The mechanical specifications are compliant to the QSFP+ MSA transceiver module specifications.
10
Optical Communication System
Datasheet Test Center Only when quality and 100% compatibility is verified and proved do our modules enter the market. This depends on FS.COM's test center which is supported by a variety of mainstream original brand switches and professional staff. We are proud of this test center and believe all of these devices worth the investments, because it brings the best to our customers. The original switches could be found nowhere but at FS.COM's test center, eg: Juniper MX960 & EX 4300 series, Cisco Nexus 9396PX & Cisco ASR 9000 Series, HP 5900 Series & HP 5406R ZL2 V3(J9996A), Arista 7050S-64, Brocade ICX7750-26Q & ICX6610-48, Avaya VSP 7000 MDA 2, etc.
Cisco ASR 9000 Series(A9K-MPA 1X40GE)
ARISTA 7050S-64(DCS-7050S-64)
Brocade ICX 7750-26Q
Extreme Networks X670V VIM-40G4X
Mellanox M3601Q
Dell N4032F
HP 5406R ZL2 V3(J9996A)
AVAYA 7024XLS(7002QQ-MDA)
+86 (755) 8300 3611
11
Juniper MX960
[email protected]
www.
Optical Communication System
Datasheet Test Assured Program FS.COM truly understands the value of compatibility and interoperability to each optics. Every module FS.COM provides must run through programming and an extensive series of platform diagnostic tests to prove its performance and compatibility. In our test center, we care of every detail from staff to facilities—professionally trained staff, advanced test facilities and comprehensive original-brand switches, to ensure our customers to receive the optics with superior quality.
Our smart data system allows effective p ro duc t m ana ge men t and q ua lity control according to the unique serial number, properly tracing the order, shipment and every part.
Our in-house coding facility programs all of our parts to standard OEM specs for compatibility on all major vendors and systems such as Cisco, Juniper, Brocade, HP, Dell, Arista and so on.
With a comprehensive line of originalbrand switches, we can recreate an environment and test each optics in practical application to ensure quality and distance.
The last test assured step to ensure our products to be shipped with perfect package.
12
Optical Communication System
Datasheet Order Information Part Number
Description
QSFP-SR4-40G
40GBASE-SR4 QSFP+ 850nm 150m MTP/MPO Transceiver for MMF
QSFP-CSR4-40G
40GBASE-CSR4 QSFP+ 850nm 400m MTP/MPO Transceiver for MMF
QSFP-PIR4-40G
40GBASE-PLRL4 QSFP+ 1310nm 1km MTP/MPO Transceiver for SMF
QSFP-LX4-40G
40GBASE-UNIV QSFP+ 1310nm 2km LC Transceiver for SMF&MMF
QSFP-IR4-40G
40GBASE-LR4L QSFP+ 1310nm 2km LC Transceiver for SMF
QSFP-LR4-40G
40GBASE-LR4 and OTU3 QSFP+ 1310nm 10km LC Transceiver for SMF
QSFP-PLR4-40G
40GBASE-PLR4 QSFP+ 1310nm 10km MTP/MPO Transceiver for SMF
QSFP-ER4-40G
40GBASE-ER4 and OTU3 QSFP+ 1310nm 40km LC Transceiver for SMF
QSFP-BD-40G
40GBASE-SR Bi-Directional QSFP LC Duplex Transceiver for MMF
Note: Every transceiver is individually tested on corresponding equipment, walks through the testing challenges and 100% compatible with Cisco, Arista, Juniper, Dell, Brocade and other brands.
Page 5 of 6
13
FS.COM
Optical Communication System
Datasheet Contact Us Fiberstore China Room 301, Third Floor, Weiyong Building, No. 10 Kefa Road, Nanshan District, Shenzhen, 518057, China Tel: +86 (755) 8300 3611 Fax: +86 (755) 8326 9395
Fiberstore U.S. 331 Andover Park East Ste330, Tukwila, WA 98188, United States Tel: +1-425-226-2035 Fax: +1-253-246-7881
Fiberstore Hong Kong 1220 Tung Chun Commercial Centre, 438-444 Shanghai Street, Kowloon, HongKong Tel: +(852) 817 636 06 Fax: +(852) 817 636 06
Fiberstore U.K. Third Floor 207 Regent Street, London, W1B 3HH, United Kingdom Tel: +44 (020) 3287 6810
Addresses, phone number and fax number also have been listed at www.fs.com. Please e-mail us at
[email protected] or call us for assistance. All statements, technical information, and recommendations related to the products here are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact FS for more information.
Fiber Optic Transceivers