Preview only show first 10 pages with watermark. For full document please download

40gbase Qsfp+ Psm4 1.5km Optical Transceiver

   EMBED


Share

Transcript

40GBase QSFP+ PSM4 1.5km Optical Transceiver PRODUCT FEATURES Supports 41.2 Gb/s aggregate bit rates Link Distance up to 1.5km over SMF fiber 4 parallel 10Gbps full duplex channels Standard 12-fiber MPO/MTP SMF connector Compatible with 4 SFP+ 10GBASE LR / LR lite transceivers via SMF breakout cable Uncooled 4x10Gb/s transmitter/PIN Diode Power dissipation < 2.5W Compliant with Hot Pluggable QSFP+ MSA (SFF-8436) Digital Diagnostic Monitoring Interface Operating case temperature range: 0°C~70°C RoHS 6 Compliant APPLICATIONS 40GBASE IEEE Interconnect up to 1.5km over SMF fiber High Performance, High Density Interconnect Data center Rack to Rack, Rack to cluster interconnect GENERAL DESCRIPTION LuxNet’s 40GBase LR/LRL QSFP+ optical transceiver is designed for 10G Ethernet Link, router line card applications, storage, IP network and LAN application operating at 10.3125Gbps with link distance up to 1.5km SMF. The optical transceiver incorporates 4 1310nm wavelength FP laser transmitters and a PIN/TIA array receiver. Digital Diagnostic Monitoring function is also provided to enable full transceiver failure/fault alarm monitoring. Technical Data of F903-CD02-3N90-E (Rev 1.0) Page 1 No. 6, Heijiang Rd., Jhongli City Tao-Yuan Hsien, TAIWAN Tel: +886-3-452-5188 Fax: +886-3-462-9588 www.luxnetcorp.com.tw Block Diagram Figure 1: Application Reference Model Host Interface Illustration Figure 2: Recommended Host Board Power Supply Filtering Technical Data of F903-CD02-3N90-E (Rev 1.0) Page 2 No. 6, Heijiang Rd., Jhongli City Tao-Yuan Hsien, TAIWAN Tel: +886-3-452-5188 Fax: +886-3-462-9588 www.luxnetcorp.com.tw Typical Application Circuit Figure 3: Example QSFP+ Host Board Schematic For Optical Modules Technical Data of F903-CD02-3N90-E (Rev 1.0) Page 3 No. 6, Heijiang Rd., Jhongli City Tao-Yuan Hsien, TAIWAN Tel: +886-3-452-5188 Fax: +886-3-462-9588 www.luxnetcorp.com.tw PERFORMANCE DESCRIPTION Absolute Maximum Ratings Parameter Symbol Unit o Min Max C -40 +85 Storage Temperature Range Ts Power Supply Voltage Vcc V 0 +3.6 Relative Humidity RH % 5 85 Recommended Operating Environment and Power Supply Characteristics Parameter Symbol Unit o Min Typ Max C 0 25 +70 3.135 3.3 3.465 Case Operating Temperature Range Tc Power Supply Voltage Vcc V Power Supply Current Icc mA 720 Power Consumption mW 2500 Data rate Gbps 10.3125 Electrical Characteristics Parameter Symbol Unit Min. Typ. Max. Notes Electrical Characteristics Transmitter Differential Input Voltage VIN mVpp 180 Receiver Differential Output Voltage VO mVpp 400 VOH Loss of Signal (LOS) 450 850 2 Vcc Vee Vee+0.8 2 Vcc Vee Vee+0.8 V VOL VIH Transmitter Disable (TX-Disable) 1 2 V VIL Rx Output Rise and Fall Time 800 Tr/Tf ps 30 20% to 80% Note1. SFF-8431, SFP+MODULE RECEIVER OUTPUT SPECIFICATIONS AT C’. Note2. LOS is an open collector output. Should be pulled up with 4.7kΩ – 10kΩ on the host board. Normal operation is logic 0; loss of signal is logic 1. Technical Data of F903-CD02-3N90-E (Rev 1.0) Page 4 No. 6, Heijiang Rd., Jhongli City Tao-Yuan Hsien, TAIWAN Tel: +886-3-452-5188 Fax: +886-3-462-9588 www.luxnetcorp.com.tw Optical Characteristics Parameter Symbol Unit Min. Typ. Max. Notes OPTICAL TRANSMITTER Average Launch Power Po dBm -8.2 +0.5 Center wavelength λc nm 1260 1355 Optical Spectral Width (RMS) Δλ nm Extinction ratio 3.5 ER dB 3.5 Launch power in OMA minus TDP, each lane O-T dB -9.4 Optical power OMA POMA dBm -4.5 Average launch power of OFF transmitted Poff dBm -30 RIN12OMA RIN dB/Hz -128 +1.5 Optical Return Loss Tolerance dB 20 Output eye Compliant with IEEE802.3ba eye mask 1 2 OPTICAL RECEIVER λc nm 1260 RxOMA dBm +1.5 Receiver Overload in average power, each lane Pmax dBm +0.5 3 Average receive power, each lane RxPx dBm -12.5 4 SenOMA dBm RCP % Center wavelength Receiver Overload in OMA, each lane Receiver Sensitivity in OMA, each lane Receiver Crossing 1355 -11.5 45 5 55 SFF-8431, SFP+MODULE RECEIVER OUTPUT SPECIFICATIONS AT C’. Receiver Eye Mask Receiver Eye Mask Margin REMM % Rrx dB Assert LOSA dBm Deassert LOSD dBm LOSH dB Receiver Reflectance 0 -15 -30 LOS LOS Hysteresis -12 +0.5 +6 Note 1: Even if the TDP < 1 dB, the OMA(min) must exceed this value Note 2: Transmitter reflectance is defined looking into the transmitter Note 3: The receiver shall be able to tolerate, without damage, continuous exposure to an optical input signal having a power level equal to the average receive power (max) plus at least 1 dB. Note 4: Average receive power (min) is informative and not the principal indicator of signal strength. A received power below this value cannot be compliant; however, a value above this does not ensure compliance. 31 Note 5: PRBS 2 -1 at BER 10 -12 , ER=3.5dB Technical Data of F903-CD02-3N90-E (Rev 1.0) Page 5 No. 6, Heijiang Rd., Jhongli City Tao-Yuan Hsien, TAIWAN Tel: +886-3-452-5188 Fax: +886-3-462-9588 www.luxnetcorp.com.tw Digital Diagnostic Function < Memory Map > Technical Data of F903-CD02-3N90-E (Rev 1.0) Page 6 No. 6, Heijiang Rd., Jhongli City Tao-Yuan Hsien, TAIWAN Tel: +886-3-452-5188 Fax: +886-3-462-9588 www.luxnetcorp.com.tw < EEPROM Serial ID Memory Contents > Accessing Serial ID Memory uses the 2 wire address 1010000X (A0H). Memory Contents of Serial ID are shown in Table as below. < Serial ID Memory Contents > Data Address Size (Bytes) Name of Field Contents(Hex) Description QSFP BASE ID FIELDS 0 1 Identifier 0D 1-2 2 Status Indicator 00 00 3-21 19 Interrupt Flags All 00 22-33 12 Module Monitors All 00 34-81 48 Channel Monitors All 00 82-85 4 Reserved 00 00 00 00 86-97 12 Control All 00 98-99 2 Reserved 00 00 100-106 7 Module & 00 00 00 00 00 00 00 Channel Masks 107-118 12 119-122 4 Reserved All 00 Password Change 00 00 00 00 Entry 123-126 4 Password Entry 00 00 00 00 127 1 Page Select 00 128 1 Identifier 0D 129 1 Ext. Identifier 00 130 1 Connector 0C 131-138 8 Specification QSFP+ MPO Connector 40G-LR4 and 10G-LR 22 00 00 00 00 00 00 00 Compliance over 1.5km 139 1 Encoding 05 64B/66B 140 1 BR-Normal 67 10.3Gbps per lane 141 1 Extended Rate Select 00 unspecified 142 1 Length SM-km 01 1km SMF 143 1 Length, OM3-2m 68 300m OM3 MMF 144 1 Length, OM2-1m 00 145 1 Length, OM1-1m 00 146 1 Length, Cu-1m 00 Technical Data of F903-CD02-3N90-E (Rev 1.0) not support copper Page 7 No. 6, Heijiang Rd., Jhongli City Tao-Yuan Hsien, TAIWAN Tel: +886-3-452-5188 Fax: +886-3-462-9588 www.luxnetcorp.com.tw 147 1 Device technology 148-163 16 Vendor name 30 1310nm FP 41 72 69 73 74 61 20 4E Arista Networks 65 74 77 6F 72 6B 73 20 Extended Module 164 1 00 Codes 165-167 3 Vendor OUI 168-183 16 Vendor Part Number 00 1C 73 51 53 46 50 2D 34 30 47 QSFP-40G-PLRL4 2D 50 4C 52 4C 20 20 20 184-185 2 Vendor rev 30 32 02 186-187 2 Wavelength 66 58 1310nm 188-189 2 Wavelength Tolerance 27 10 50nm 190 1 Max case temp 46 70C 191 1 Check code for xx [128-190] Tx_DISABLE, Tx_FAULT, 192-195 4 Options 00 00 00 1A and Tx Loss of Signal implemented 58 53 4D 31 34 31 30 30 196-211 16 Vendor SN Example:XSM141000001 30 30 30 31 20 20 20 20 212-219 8 Data code 31 34 30 33 31 34 30 31 Example:14031401 220 1 DOM type 08 For average power 221 1 Enhanced Options 00 222 1 Reserved 00 223 1 Check code for xx [192-222] 10 03 00 00 00 00 00 00 00 00 00 00 00 00 00 00 224-251 28 Arista specified 00 00 00 00 00 00 02 F8 00 00 00 00 CRC-32 for bytes 252-255 4 xx xx xx xx 128-251 Technical Data of F903-CD02-3N90-E (Rev 1.0) Page 8 No. 6, Heijiang Rd., Jhongli City Tao-Yuan Hsien, TAIWAN Tel: +886-3-452-5188 Fax: +886-3-462-9588 www.luxnetcorp.com.tw Low Speed Electrical Specification Module Electrical Pin Definition Figure 4: Interface to Host PCB Technical Data of F903-CD02-3N90-E (Rev 1.0) Page 9 No. 6, Heijiang Rd., Jhongli City Tao-Yuan Hsien, TAIWAN Tel: +886-3-452-5188 Fax: +886-3-462-9588 www.luxnetcorp.com.tw Pin Definition Table Technical Data of F903-CD02-3N90-E (Rev 1.0) Page 10 No. 6, Heijiang Rd., Jhongli City Tao-Yuan Hsien, TAIWAN Tel: +886-3-452-5188 Fax: +886-3-462-9588 www.luxnetcorp.com.tw Mechanical Dimensions Comply to SFF-8436 rev. 4.2, for QSFP+ 10 Gbs 4X PLUGGABLE TRANSCEIVER, tab color in yellow Figure 5: Drawing of QSFP+ Module Regulatory Compliance Feature Test Method Performance FDA 21 CFR 1040.10 and 1040.11 IEC 60825-1: 1994+ A11: 1996+ A2: 2001 Compliant with Class 1 Laser Eye Safety IEC 60825-2: 2004 + A1: 2006 laser product EN 60825-1:1994+A1:2002+A2:2001 EN 60825-2: 2004 MIL-STD-883E Electrostatic Discharge (ESD) to Class 1 (>1.5kV) Method 3015.4 the Electrical Pins Human Body Model Technical Data of F903-CD02-3N90-E (Rev 1.0) Page 11 No. 6, Heijiang Rd., Jhongli City Tao-Yuan Hsien, TAIWAN Tel: +886-3-452-5188 Fax: +886-3-462-9588 www.luxnetcorp.com.tw Electrostatic Discharge IEC 61000-4-2: 2001 Class 2 (>4.0kV) (ESD) Immunity FCC Part 15 Subpart J Class B Electromagnetic Interference CISPR22:1997+A1:2000+A2:2002, Class B Compliant with standards (EMI) EN55022:1998+A1:2000+A2:2003, Class B Ordering Information Specification Part No Package Data rate Laser Optical Power Detector per Lane F903-CD02-3N90-E QSFP+ 10.3 Gbps Max. Receive Temp Reach Other Sensitivity 1310nm FP -8.2 dBm~ +0.5 dBm PIN -12.5 dBm in OMA code 0~70oC 1.5km for SMF DDM 40GBASE- RoHS LR4L Document Category: Product Specification (Data Sheet) Product Name: 40GBase PLR4-Lite QSFP+ Optical Transceivers Part Number: F903-CD02-3N90-E Revision: 1.0 (May. 5th, 2014) Revision History Rev Date Modification 1.0 May. 2014 Initial Release Technical Data of F903-CD02-3N90-E (Rev 1.0) Application Note Page 12