Preview only show first 10 pages with watermark. For full document please download

4100-123

   EMBED


Share

Transcript

230/208-60-1 15 14 12 10 9 6 3 2 1 Orange 1 2 3 Green L2 T2 E Black Black/White Terminal Block #3 10 Red 27 C C Black/White Tan Black Low Ambient Control (Opt.) Blue LC L1 L0 S S 42 45 C RV TWV Outdoor Fan 12 Motor Controller S C Compressor High Press. Switch Black R Blue 12 Blue Blue Blue Black 9 Terminal Block #4 Red Yellow Blue 13 Dual Can Green SEN TERM SPEED UP JMP TEMP 30 60 90 12 Low Pressure Switch 44 Defrost Sensor Reversing Valve Defrost Control Term. Block RV #5 RV W2 L 3 6 7 9 4 Electric Heat Relay (Opt.) Electric Heat Relay 3 T. Block #2 11 Compressor Contactor Reversing Valve Heater Contactor #2 D Y Terminal Block #5 11 F 5 1 Plug #2 A Term. Block #5 C Heater Contactor #1 C 2 Gnd 3 Low Ambient Bypass W2 D T2 Term. Block L. A. Bypass (Opt.) #3 CC B A L. A. Control (Opt.) A T1 T. Block #2 Pressure Lockout Indicator O. Motor Controller 1 Y B 6 46 Blue/Black T1 T2 Red 17 Capacitor H 7 51 28 Red/Black Black Blue/Red Brown Yellow Blk Low Ambient Bypass (Opt.) 4 T1 T2 36 L1 47 Black Blue 1 Defrost Control CC NC COM T. Block #2 9 39 Red COM Ground 3 2 6 5 41 L 42 L1 Y L Y 30 L2 Defrost Sensor H Low Pressure Term. Block Control #5 8 Upper Control Panel 32 TWV 2 1 Lower Control Panel 27 SENSOR C T. Block #2 Tan 57 SENSOR R LO L0 7 COM Black/White Transformer 60 Term. Block #5 4 NC SENSOR Red C 40 Black/White R L2 LC Black 208 Yellow/Red T2 COM 24VAC Transformer L1 L2 RV 26 Red 240 R Red R 35 Black Red/White 26 38 Yellow Black/White 33 Yellow/Red T1 LO R R W2 B Term. Block #4 240 208 T. Block #2 Term. High Pressure Block #5 Control 34 48 59 T2 Outdoor Fan Motor Controller 29 Purple/White L1 58 27 Black/White L 49 37 Black Compressor Contactor C Pink Blue Pressure Lockout 61 Indicator Brown Pink 43 F Blk/Whte B W2 R Red/White Y Red/Whte Brown Blue Yellow G2 C T1 10 Yellow/Red Pink Compressor Contactor C 31 11 T1 Term. Block #4 Brown Black Black/White 1 2 3 Red Yellow L1 Black Plug #1 S Compressor Contactor G Plug #1 Compressor Capacitor L2 Red/Yellow Red/White 1 2 3 R Orange Brown Blk/Whte Blue 25 Plug #3 Black/White Terminal Block #2 L2 L1 Brown/White G Black Black 1 2 3 4 5 6 7 8 9 10 11 12 Purple Orange Plug #2 Red/Whte 23 24 230/208-60-1 L1 Condenser Section Indoor Blower Motor 1 2 3 B C T. Block #2 T. Block #2 G G2 1 3 2 9 6 14 12 10 15 Indoor Blower Motor Plug #3 D Labeled wires connect if no options used. E Move Red wire to 208V tap for 208V operation. Install jumper for hi speed blower oper. on F models 36, 42, 48, and 60. ! WARNING Remove jumper when Low Amb. Bypass is USE COPPER CONDUCTORS H installed. ONLY SUITABLE FOR AT LEAST Factory High Voltage Low Voltage Field Optional 75° C. ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. Bard Mfg. Co. Bryan, Ohio 4100-123