Preview only show first 10 pages with watermark. For full document please download

4100-125

   EMBED


Share

Transcript

230/208-60-1 15 14 12 10 9 6 3 2 1 Orange L1 25 38 Terminal Block #3 10 Black H 7 12 Low Ambient Control (Opt.) Outdoor Fan Motor 12 R S LC L1 L0 C Compressor High Press. Switch 1 Low Pressure Switch SEN TERM SPEED UP JMP TEMP 30 60 90 45 Defrost Sensor Purple/White Tan S Black/White S 3 4 44 C RV TWV Reversing Valve SENSOR R SENSOR C L2 C CC Y T. Block #2 11 W2 L 3 D Compressor Contactor 6 7 9 4 Electric Heat Relay (Opt.) Electric Heat Relay T. Block #2 Term. Block #5 Reversing Valve C Low Ambient Bypass W2 3 Heater Contactor #2 Heater Contactor #1 C D Plug #1 2 2 Y F 5 1 1 2 3 Plug #2 A Freeze stat RV 7 Terminal Block #5 C Defrost Sensor T. Block #2 Pressure Lockout Indicator 11 NC Defrost Control Defrost Control Term. Block RV #5 B B 6 Gnd A LO Y 9 Defrost Control 51 Black 12 Plug #1 R L1 Low Pressure Term. Block Control #5 L Black 13 Brown Yellow Black/White Tan Black T1 T2 9 Term. Block #3 H L0 TWV 8 28 Blue/Black C Red Blue/Red H Dual Can Terminal Capacitor 17 Block #2 Black T1 T2 Blk F Blue 4 Low Ambient Bypass (Opt.) Black 1 F1 Low Ambient Control (Opt.) T. Block #2 42 3 F2 L2 24VAC Transformer Term. Block #5 4 2 1 39 47 Red 3 2 6 5 COM A Term. Block #3 T2 Term. Block #4 COM R 7 NC SENSOR 42 Black/White Ground C 30 Blue Black C Blue 57 L1 Blue 32 CC Blue 27 Red/Black COM Transformer E 27 46 Red C 40 60 36 L Outdoor Fan Motor LC 35 Black 208 Black/White Red 240 R Red 41 Freeze stat 26 Y F 1 T. Block #2 L2 RV Blue Black/White Red/White 26 LO R W2 B C L1 34 R T2 Term. Block High Pressure #5 Control Upper Control Panel T2 Yellow Yellow Black/White T1 48 58 27 Black 36 33 Black Pink L2 49 37 Black L L1 59 Red Red/Whte Blk/Whte C Red/White Pressure Lockout 61 Indicator Brown Pink 43 F R 11 Pink B W2 Blue Y Brown Blue Yellow G G2 Compressor Contactor T1 Term. Block #4 29 31 Terminal Block #2 T1 10 Lower Control Panel Yellow Blue C 240 208 Condenser Section Purple Compressor Contactor Low Ambient Bypass (Opt.) Dual Can Capacitor Brown Yellow 1 2 3 4 Black/White Plug #1 Yellow L1 L2 Compressor S Green Red/White H Compressor Contactor G Red/Yellow Black/White Orange 1 2 3 Brown/White L2 Red Plug #3 R Black Blk/Whte Brown Blue Black 1 2 3 4 5 6 7 8 9 10 11 12 Purple Orange 24 Red/Whte 23 Plug #2 230/208-60-1 L1 Black Indoor Blower Motor B C T. Block #2 Plug #3 T. Block #2 G G2 1 3 2 9 6 14 12 10 15 Indoor Blower Motor D Labeled wires connect if no options used. E Move Red wire to 208V tap for 208V operation. Install jumper for hi speed blower oper. on F models 36, 42, 48, and 60. ! WARNING Remove jumper when Low Amb. Bypass is USE COPPER CONDUCTORS H installed. ONLY SUITABLE FOR AT LEAST Factory High Voltage Low Voltage Field Optional 75° C. ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. 4100-125